Property Inspection Report

Client(s):  Mr. & Mrs. Investor
Property address:  2021 Investor Ave
Missoula Mt 59803
Inspection date:  Friday, January 1, 2021

This report published on Monday, February 15, 2021 2:51:30 PM MST

This report is the exclusive property of this inspection company and the client(s) listed in the report title. Use of this report by any unauthorized persons is prohibited.

How to Read this Report
This report is organized by the property's functional areas. Within each functional area, descriptive information is listed first and is shown in bold type. Items of concern follow descriptive information. Concerns are shown and sorted according to these types:
Concern typeSafetyPoses a safety hazard
Concern typeRepair/ReplaceRecommend repairing or replacing
Concern typeRepair/MaintainRecommend repair and/or maintenance
Concern typeMinor DefectCorrection likely involves only a minor expense
Concern typeMaintainRecommend ongoing maintenance
Concern typeEvaluateRecommend evaluation by a specialist
Concern typeCommentFor your information
Concern typeDamageDamage caused by wood destroying insects or organisms (Rot, carpenter ant galleries, etc.)
Concern typeConducive conditionsConditions conducive for wood destroying insects or organisms (Wood-soil contact, shrubs in contact with siding, roof or plumbing leaks, etc.)

Click here for a glossary of building construction terms.Contact your inspector If there are terms that you do not understand, or visit the glossary of construction terms at https://www.reporthost.com/glossary.asp

Table of Contents

General Information
Exterior and Foundation
Roof
Grounds
Interior, Doors and Windows
Kitchen
Bathrooms, Laundry and Sinks
Basement
Electric
Heating, Ventilation and Air Condition (HVAC)
Plumbing / Fuel Systems
Water Heater
Attic and Roof Structure
Wood Destroying Organism Findings

View summary

General InformationTable of contents
Report number: Investor#1
Time started: 8:50 am
Time finished: 3:35 pm
Present during inspection: Tenants
Client present for discussion at end of inspection: No
Weather conditions during inspection: Dry (no rain or snow) yet! : )
Temperature during inspection: Freezing, 24 degrees and warming to 33 degrees
Type of building: Multiplex
Buildings inspected: 6-plex
Number of residential units inspected: 6
Age of main building: 1980
Source for main building age: Client, Municipal records or property listing
Front of building faces: North
Main entrance faces: South
Occupied: Yes, Furniture or stored items were present
1) Structures built prior to the mid 1980s may contain lead and/or asbestos. Lead is commonly found in paint and in some plumbing components. The EPA does not recognize newer coats of paint as encapsulating older coats of lead-based paint. Asbestos is commonly found in various building materials such as insulation, siding, and/or floor and ceiling tiles. Laws were passed in 1978 to prohibit usage of lead and asbestos, but stocks of materials containing these substances remained in use for a number of years thereafter. Both lead and asbestos are known health hazards. Evaluating for the presence of lead and/or asbestos is beyond the scope of this inspection. Any mention of these materials in this report is made as a courtesy only, and meant to refer the client to a specialist. Consult with specialists as necessary, such as industrial hygienists, professional labs and/or abatement specialists for this type of evaluation. For information on lead, asbestos and other hazardous materials in homes, visit:
http://www.reporthost.com/?EPA
http://www.reporthost.com/?CPSC
http://www.reporthost.com/?CDC
2) Many areas and items at this property were obscured by furniture and/or stored items. This often includes but is not limited to walls, floors, windows, inside and under cabinets, under sinks, on counter tops, in closets, behind window coverings, under rugs or carpets, and under or behind furniture. Areas around the exterior, under the structure, in the garage and in the attic may also be obscured by stored items. The inspector in general does not move personal belongings, furnishings, carpets or appliances. When furnishings, stored items or debris are present, all areas or items that are obscured, concealed or not readily accessible are excluded from the inspection. The client should be aware that when furnishings, stored items or debris are eventually moved, damage or problems that were not noted during the inspection may be found.
Exterior and FoundationTable of contents
Limitations: The inspector performs a visual inspection of accessible components or systems at the exterior. Items excluded from this inspection include below-grade foundation walls and footings; foundations, exterior surfaces or components obscured by vegetation, stored items or debris; wall structures obscured by coverings such as siding or trim. Some items such as siding, trim, soffits, vents and windows are often high off the ground, and may be viewed using binoculars from the ground or from a ladder. This may limit a full evaluation. Regarding foundations, some amount of cracking is normal in concrete slabs and foundation walls due to shrinkage and drying. Note that the inspector does not determine the adequacy of seismic reinforcement.
Wall inspection method: Viewed from ground and balcony
Condition of wall exterior covering: Appeared serviceable, but required repairs, replacement and/or evaluation (see comments below)
Apparent wall structure: Wood frame
Wall covering: Plywood type, like T1-11, Wood fiber,
Condition of foundation and footings: Appeared serviceable
Apparent foundation type: Finished basement, Concrete slab on grade
Foundation/stem wall material: Poured in place concrete
Footing material (under foundation stem wall): Not determined (inaccessible or obscured)
3) There was more than one missing window well cover. This is a potential fall/safety hazard. Recommend a qualified person install approved well covers.
Photo
Photo 3-1 
Photo
Photo 3-2 
4) DamageFungal rot was found at one or more sections of siding or trim. Conducive conditions for rot should be corrected (e.g. wood-soil contact, reverse perimeter slope). Recommend that a qualified contractor repair as necessary. All rotten wood should be replaced.
Photo
Photo 4-1 
Photo
Photo 4-2 
Photo
Photo 4-3 
Photo
Photo 4-4 
Photo
Photo 4-5 
5) Conducive conditionsFlashing at one or more locations was loose. Leaks can occur as a result. Recommend that a qualified person repair, replace or install flashing as necessary, and per standard building practices.
Photo
Photo 5-1 Upstairs
6) Conducive conditionsThere was one or more loose dryer vents. This can allow moisture to easily penetrate the siding causing damage. Recommend a qualified person repair and seal any loose loose vents.
Photo
Photo 6-1 
7) One or more minor cracks (1/8 inch or less) were found in the foundation. These didn't appear to be a structural concern, but recommend sealing them to prevent water infiltration and monitor them in the future. Numerous products exist to seal such cracks including hydraulic cement, non-shrinking grout, resilient caulks and epoxy sealants.
Photo
Photo 7-1 
8) The retaining wall staircase had moderate cracking. This can allow water to penetrate causing further damage. Recommend a qualified person seal with an approved sealant for concrete.
Photo
Photo 8-1 
Photo
Photo 8-2 
9) Unit #5; The doorbell was damaged and inoperable. Recommend a qualified person replace the doorbell so it functions properly.
Photo
Photo 9-1 
10) Conducive conditionsVegetation such as trees, shrubs and/or vines was in contact with or close to the building exterior. Vegetation can serve as a pathway for wood-destroying insects and can retain moisture against the exterior after it rains. This is a conducive condition for wood-destroying organisms. Recommend pruning, moving or removing vegetation as necessary to maintain at least 6 inches of space between it and the building exterior. A 1-foot clearance is better.
Photo
Photo 10-1 
11) Conducive conditionsTrees were in contact with or were close to the building at one or more locations. Damage to the building can occur, especially during high winds, or may have already occurred (see other comments in this report). Recommend that a qualified tree service contractor or certified arborist trim or remove trees as necessary to prevent damage to the building exterior.
Photo
Photo 11-1 
Photo
Photo 11-2 Roof damage
12) Conducive conditionsThe paint or stain finish in several areas was failing (e.g. peeling, faded, worn, thinning). Siding and trim with a failing finish can be damaged by moisture. Recommend that a qualified contractor prep (e.g. clean, scrape, sand, prime, caulk) and repaint or restain the building exterior where necessary and per standard building practices. Any repairs needed to the siding or trim should be made prior to this.
Photo
Photo 12-1 
Photo
Photo 12-2 
Photo
Photo 12-3 
Photo
Photo 12-4 
Photo
Photo 12-5 
Photo
Photo 12-6 
Photo
Photo 12-7 
Photo
Photo 12-8 
Photo
Photo 12-9 
Photo
Photo 12-10 
Photo
Photo 12-11 
Photo
Photo 12-12 
13) Conducive conditionsCaulk was missing and/or deteriorated in some areas. For example, around doors. Recommend that a qualified person renew or install caulk as necessary. Where gaps are wider than 1/4 inch, an appropriate material other than caulk should be used. For more information, visit:
http://www.reporthost.com/?CAULK
Photo
Photo 13-1 
Photo
Photo 13-2 
14)  Exterior
Photo
Photo 14-1 
Photo
Photo 14-2 
Photo
Photo 14-3 
Photo
Photo 14-4 
Photo
Photo 14-5 
Photo
Photo 14-6 
Photo
Photo 14-7 
15)  Foundation
Photo
Photo 15-1 
Photo
Photo 15-2 
Photo
Photo 15-3 
Photo
Photo 15-4 
Photo
Photo 15-5 
Limitations: The following items or areas are not included in this inspection: areas that could not be traversed or viewed clearly due to lack of access; solar roofing components. Any comments made regarding these items are made as a courtesy only. Note that the inspector does not provide an estimate of remaining life on the roof surface material, nor guarantee that leaks have not occurred in the roof surface, skylights or roof penetrations in the past. Regarding roof leaks, only active leaks, visible evidence of possible sources of leaks, and evidence of past leaks observed during the inspection are reported on as part of this inspection. The inspector does not guarantee or warrant that leaks will not occur in the future. Complete access to all roof and attic spaces during all seasons and during prolonged periods of all types of weather conditions (e.g. high wind and rain, melting snow) would be needed to do so. Occupants should monitor the condition of roofing materials in the future. For older roofs, recommend that a professional inspect the roof surface, flashings, appurtenances, etc. annually and maintain/repair as might be required. If needed, the roofer should enter attic space(s). Regarding the roof drainage system, unless the inspection was conducted during and after prolonged periods of heavy rain, the inspector was unable to determine if gutters, downspouts and extensions perform adequately or are leak-free.
Roof inspection method: Traversed
Condition of roof surface material: Required repair, replacement and/or evaluation, roof may be at or beyond life expectancy. (see comments below).
Roof surface material: Asphalt or fiberglass composition shingles
Roof type: Gable
Apparent number of layers of roof surface material: One
Condition of exposed flashings: Required repair, replacement and/or evaluation (see comments below)
Condition of gutters, downspouts and extensions: Appeared serviceable, but required repair, replacement and/or evaluation (see comments below). Limited evaluation due to little or no rainfall during and prior to the inspection
16) Conducive conditionsMany composition shingles were broken, missing and/or damaged. Leaks can occur as a result. This is a conducive condition for wood-destroying organisms. Recommend that a qualified contractor further evaluate and repair or replace as deemed necessary.
Photo
Photo 16-1 
Photo
Photo 16-2 
Photo
Photo 16-3 
Photo
Photo 16-4 
Photo
Photo 16-5 
Photo
Photo 16-6 
Photo
Photo 16-7 
17) Conducive conditionsThe roof surface appeared to be near the end of its service life and will likely need replacing in the near future even if repairs are made now. Recommend discussing replacement options with a qualified contractor, and budgeting for a replacement roof surface in the near future. The client may also wish to consider having a qualified contractor attempt to issue a "5 year roof certificate."
Photo
Photo 17-1 
Photo
Photo 17-2 
Photo
Photo 17-3 
Photo
Photo 17-4 
Photo
Photo 17-5 
Photo
Photo 17-6 
18) Conducive conditionsOne or more rubber or neoprene pipe flashings were split or cracked. Leaks can occur as a result. This is a conducive condition for wood-destroying organisms. Recommend that a qualified contractor replace flashings where necessary.
Photo
Photo 18-1 
19) Conducive conditionsMore than one roof vents were corroded. This is a potential leak problem. Refer to comment above.
Photo
Photo 19-1 
Photo
Photo 19-2 
20) Extensions such as splash blocks or drain pipes for one or more downspouts were missing. Water can accumulate around the building foundation or inside crawl spaces or basements as a result. Recommend that a qualified person install, replace or repair extensions as necessary so rainwater drains away from the structure.
Photo
Photo 20-1 
21) Conducive conditionsSignificant amounts of debris have accumulated in one or more gutters or downspouts. Gutters can overflow and cause water to come in contact with the building exterior, or water can accumulate around the foundation. This is a conducive condition for wood-destroying organisms. Recommend cleaning gutters and downspouts now and as necessary in the future.
Photo
Photo 21-1 
Limitations: Unless specifically included in the inspection, the following items and any related equipment, controls, electric systems and/or plumbing systems are excluded from this inspection: detached buildings or structures; fences and gates; retaining walls; underground drainage systems, catch basins or concealed sump pumps; swimming pools and related safety equipment, spas, hot tubs or saunas; whether deck, balcony and/or stair membranes are watertight; trees, landscaping, properties of soil, soil stability, erosion and erosion control; ponds, water features, irrigation or yard sprinkler systems; sport courts, playground, recreation or leisure equipment; areas below the exterior structures with less than 3 feet of vertical clearance; invisible fencing; sea walls, docks and boathouses; retractable awnings. Any comments made regarding these items are as a courtesy only.
Site profile: Minor slope
Condition of driveway: Appeared serviceable, but required repair, replacement and/or evaluation (see comments below)
Driveway material: Asphalt
Condition of sidewalks and/or patios: Appeared serviceable, but required repairs, replacement and/or evaluation (see comments below)
Sidewalk material: Poured in place concrete
Condition of deck, patio and/or porch covers: Appeared serviceable, but required repairs, replacement and/or evaluation (see comments below)
Deck, patio, porch cover material and type: Covered (Refer to Roof section)
Condition of decks, porches and/or balconies: Appeared serviceable, but required repairs, replacement and/or evaluation (see comments below)
Deck, porch and/or balcony material: Wood
Condition of stairs, handrails and guardrails: Appeared serviceable, but required repairs, replacement and/or evaluation (see comments below)
Exterior stair material: Wood, Metal
22) Guardrails at one or more locations with drop-offs higher than 30 inches had gaps that were too large. This poses a safety hazard for children (e.g. falling, getting stuck in railing). Guardrails should not have gaps or voids that allow passage of a sphere equal to or greater than 4 inches in diameter, or 6 inches in diameter at triangular spaces between stair edges and guardrails. At a minimum, the client should be aware of this hazard. Recommend that a qualified contractor repair or replace guardrails per standard building practices.
Photo
Photo 22-1 
Photo
Photo 22-2 
23) Cracks, holes, settlement, heaving and/or deterioration were found in the driveway causing a potential trip hazard. Recommend that qualified contractor repair as necessary.
Photo
Photo 23-1 
24) DamageFungal rot was found in plywood sheathing and/or soffit at one or more decks or porches. Recommend that a qualified contractor evaluate and repair as necessary. All rotten wood should be replaced.
Photo
Photo 24-1 
Photo
Photo 24-2 
25) Cracks, holes, settlement, heaving and/or deterioration were found in sidewalks and/or patios. Recommend that qualified contractor repair or seal as deemed necessary.
Photo
Photo 25-1 
Photo
Photo 25-2 
Photo
Photo 25-3 
26) The concrete sidewalk/stairs were damaged and or deteriorated. If left un-repaired it will only deteriorate further. Recommend a qualified concrete contractor make necessary repairs.
Photo
Photo 26-1 
27) The asphalt driveway surface was worn and is prone to developing cracks from water penetration. Recommend that a qualified person reseal the driveway. For more information, visit:
http://www.reporthost.com/?RAD
Photo
Photo 27-1 
Photo
Photo 27-2 
Photo
Photo 27-3 
Photo
Photo 27-4 
28) Wooden deck or porch surfaces and/or railings were overdue for normal maintenance. Recommend that a qualified person clean and preserve as necessary. Where decks have been coated with a finish such as opaque stains or paint, it may be too difficult to strip the finish and apply anything but paint or opaque stain. Where transparent stain or penetrating oil has been applied in the past, recommend that a penetrating oil be used. For more information, visit:
http://www.reporthost.com/?PENOIL
http://www.reporthost.com/?DKMAIN
Photo
Photo 28-1 
Photo
Photo 28-2 
Photo
Photo 28-3 
Photo
Photo 28-4 
29)  Surrounding grounds
Photo
Photo 29-1 
Photo
Photo 29-2 
Photo
Photo 29-3 
Photo
Photo 29-4 
Photo
Photo 29-5 
Photo
Photo 29-6 
Photo
Photo 29-7 
Photo
Photo 29-8 
Photo
Photo 29-9 
Photo
Photo 29-10 
Photo
Photo 29-11 
Photo
Photo 29-12 
Photo
Photo 29-13 
Photo
Photo 29-14 
Interior, Doors and WindowsTable of contents
Limitations: The following items are not included in this inspection: security, intercom and sound systems; communications wiring; central vacuum systems; elevators and stair lifts; cosmetic deficiencies such as nail-pops, scuff marks, dents, dings, blemishes or issues due to normal wear and tear in wall, floor and ceiling surfaces and coverings, or in equipment; deficiencies relating to interior decorating; low voltage and gas lighting systems. Any comments made regarding these items are as a courtesy only. Note that the inspector does not evaluate any areas or items which require moving stored items, furnishings, debris, equipment, floor coverings, insulation or similar materials. The inspector does not test for asbestos, lead, radon, mold, hazardous waste, urea formaldehyde urethane, or any other toxic substance. Some items such as window, drawer, cabinet door or closet door operability are tested on a sampled basis. The client should be aware that paint may obscure wall and ceiling defects, floor coverings may obscure floor defects, and furnishings may obscure wall, floor and floor covering defects. If furnishings were present during the inspection, recommend a full evaluation of walls, floors and ceilings that were previously obscured when possible. Determining the cause and/or source of odors is not within the scope of this inspection.
Condition of exterior entry doors: Appeared serviceable, but required repairs, replacement and/or evaluation (see comments below)
Exterior door material: Metal
Condition of interior doors: Appeared serviceable, but required repair, replacement and/or evaluation (see comments below)
Condition of windows and skylights: Appeared serviceable
Type(s) of windows: Vinyl, Multi-pane, Sliding, Single-hung
Condition of walls and ceilings: Appeared serviceable, but required repairs, replacement and/or evaluation (see comments below)
Wall type or covering: Drywall, Wallpaper
Ceiling type or covering: Drywall, Acoustic spray
Condition of flooring: Appeared serviceable, but required repairs, replacement and/or evaluation (see comments below)
Condition of concrete slab floor(s): Appeared serviceable
Flooring type or covering: Carpet, Vinyl, linoleum or marmoleum, Laminate
30) Basement Units #1 and 6; One or more bedroom windows had substandard egress by today's standard building practices. Adequate egress is important in the event of a fire or emergency to allow escape or to allow access by emergency personnel. Bedroom windows had an opening size that was too small and/or were too high above the floor inside. This is a potential safety hazard. Standard building practices require that every bedroom have at least one egress window or an exterior entry door. Egress windows must comply with these requirements:
  • Minimum width of opening: 20 inches
  • Minimum height of opening: 24 inches
  • Minimum net clear opening at a grade floor egress windows: 5 square feet
  • Minimum net clear opening of other egress windows: 5.7 square feet
  • Maximum height of base of opening above grade or landing of grade floor egress windows: 44 inches
  • Maximum height of base of opening above interior side floor: 44 inches
  • Windows should open easily without the use of keys or tools
And for window wells below grade:
  • Minimum net clear area of 9 square feet
  • Minimum horizontal projection and width of 36 inches
  • Wells with a vertical depth greater than 44 inches require a permanent ladder or steps usable with the window in the fully open position
Where windows are too high, at a minimum, keep something that serves as a ladder below the window at all times. Recommend that a qualified contractor repair or make modifications per standard building practices. For more information, visit:
http://www.reporthost.com/?EGRESS
Photo
Photo 30-1 
Photo
Photo 30-2 
31) Unit #2; One or more exterior door thresholds and or weather stripping were significantly damaged or deteriorated. Recommend that a qualified person replace door(s) as necessary.
Photo
Photo 31-1 
Photo
Photo 31-2 
Photo
Photo 31-3 
32) More than one unit; One or more interior doors were damaged and/or deteriorated. Recommend that a qualified person replace or repair doors as necessary.
Photo
Photo 32-1 
Photo
Photo 32-2 
Photo
Photo 32-3 
Photo
Photo 32-4 
Photo
Photo 32-5 
33) More than one unit; Some interior door hardware was loose and/or missing. Recommend that a qualified person repair or replace as necessary.
Photo
Photo 33-1 
Photo
Photo 33-2 
Photo
Photo 33-3 
Photo
Photo 33-4 
Photo
Photo 33-5 
34) Units #1, 2, 3, 5 and 6; One or more walls and/or ceilings had substandard or unfinished repairs. Recommend that a qualified person repair as deemed necessary.
Photo
Photo 34-1 
Photo
Photo 34-2 
Photo
Photo 34-3 
Photo
Photo 34-4 
Photo
Photo 34-5 
Photo
Photo 34-6 
Photo
Photo 34-7 
Photo
Photo 34-8 
Photo
Photo 34-9 
Photo
Photo 34-10 
35) Unit #2; There was missing wall/floor base in one or more areas. Recommend a qualified person install base.
Photo
Photo 35-1 
Photo
Photo 35-2 
36) One or more interior doors were sticking in the door jamb and were difficult to operate. Recommend that a qualified person repair as necessary. For example, by trimming doors.
Photo
Photo 36-1 
Photo
Photo 36-2 
37) Minor cracks, nail pops and/or blemishes were found in walls and/or ceilings in one or more areas. Cracks and nail pops are common, are often caused by lumber shrinkage or minor settlement, and can be more or less noticeable depending on changes in humidity. They did not appear to be a structural concern, but the client may wish to repair these for aesthetic reasons. For recurring cracks, consider using an elastic crack covering product:
http://www.reporthost.com/?ECC
Photo
Photo 37-1 
Photo
Photo 37-2 
Photo
Photo 37-3 
38) Unit #3; One or more hinged exterior doors had no deadbolt lock installed and relied solely on the entry lockset for security. Recommend installing locksets on exterior doors where missing for added security.
Photo
Photo 38-1 
39)  Unit #1
Photo
Photo 39-1 
Photo
Photo 39-2 
Photo
Photo 39-3 
Photo
Photo 39-4 
Photo
Photo 39-5 
Photo
Photo 39-6 
Photo
Photo 39-7 
Photo
Photo 39-8 
Photo
Photo 39-9 
Photo
Photo 39-10 
40)  Unit #2
Photo
Photo 40-1 
Photo
Photo 40-2 
Photo
Photo 40-3 
Photo
Photo 40-4 
Photo
Photo 40-5 
Photo
Photo 40-6 
Photo
Photo 40-7 
Photo
Photo 40-8 
41)  Unit # 3
Photo
Photo 41-1 
Photo
Photo 41-2 
Photo
Photo 41-3 
Photo
Photo 41-4 
Photo
Photo 41-5 
42)  Unit #4
Photo
Photo 42-1 
Photo
Photo 42-2 
Photo
Photo 42-3 
Photo
Photo 42-4 
Photo
Photo 42-5 
Photo
Photo 42-6 
Photo
Photo 42-7 
43)  Unit #5
Photo
Photo 43-1 
Photo
Photo 43-2 
Photo
Photo 43-3 
Photo
Photo 43-4 
Photo
Photo 43-5 
Photo
Photo 43-6 
Photo
Photo 43-7 
Photo
Photo 43-8 
44)  Unit #6
Photo
Photo 44-1 
Photo
Photo 44-2 
Photo
Photo 44-3 
Photo
Photo 44-4 
Photo
Photo 44-5 
Photo
Photo 44-6 
Photo
Photo 44-7 
Photo
Photo 44-8 
Photo
Photo 44-9 
Limitations: The following items are not included in this inspection: household appliances such as stoves, ovens, cook tops, ranges, warming ovens, griddles, broilers, dishwashers, trash compactors, refrigerators, freezers, ice makers, hot water dispensers and water filters; appliance timers, clocks, cook functions, self and/or continuous cleaning operations, thermostat or temperature control accuracy, and lights. Any comments made regarding these items are as a courtesy only. Note that the inspector does not provide an estimate of the remaining life of appliances, and does not determine the adequacy of operation of appliances. The inspector does not note appliance manufacturers, models or serial numbers and does not determine if appliances are subject to recalls. Areas and components behind and obscured by appliances are inaccessible and excluded from this inspection.
Condition of counters: Appeared serviceable
Condition of cabinets: Appeared serviceable, but required repair, replacement and/or evaluation (see comments below)
Condition of sinks and related plumbing: Appeared serviceable, but required repair, replacement and/or evaluation (see comments below)
Condition of under-sink food disposal: N/A (none installed)
Condition of dishwasher: N/A (none installed)
Condition of ranges, cooktops and/or ovens: Required repairs, replacement and/or evaluation (see comments below)
Range, cooktop, oven type: Electric
Type of ventilation: Hood or built into microwave over range or cooktop
Condition of refrigerator: Appeared serviceable
Condition of built-in microwave oven: N/A (none installed)
45) All Units; The range could tip forward. An anti-tip bracket may not be installed. This is a potential safety hazard since the range can tip forward when weight is applied to the open door, such as when a small child climbs on it or if heavy objects are dropped on it. Anti-tip brackets have been sold with all free-standing ranges since 1985. Recommend installing an anti-tip bracket to eliminate this safety hazard. For more information, visit:
http://www.reporthost.com/?ATB
Photo
Photo 45-1 
Photo
Photo 45-2 
46) All Units; The exhaust fan over the range recirculated the exhaust air back into the kitchen. This may be due to no duct being installed, baffles not being installed, or problems with duct work. This can be a nuisance for odor and grease accumulation. Where a gas-fired range or cook top is installed, carbon monoxide and excessive levels of moisture can accumulate in living spaces. Recommend that a qualified contractor evaluate and repair as necessary so exhaust air is ducted outdoors.
Photo
Photo 46-1 
Photo
Photo 46-2 
47) One or more cabinets, drawers and/or cabinet doors were damaged or deteriorated. Recommend that a qualified person repair or replace as necessary.
Photo
Photo 47-1 
Photo
Photo 47-2 
Photo
Photo 47-3 
48) 1 cooktop element(s) was inoperable on more than one cooktop. Recommend that a qualified person repair as necessary.
Photo
Photo 48-1 
Photo
Photo 48-2 
Photo
Photo 48-3 
49) Conducive conditionsUnit #2; Water was leaking at the sink faucet base or handles. Water damage can occur as a result. Recommend that a qualified plumber repair as necessary.
Photo
Photo 49-1 
50) Gaps, no caulk, or substandard caulking were found between countertops and backsplashes. Water may penetrate these areas and cause damage. Recommend that a qualified person repair as necessary. For example, by installing caulk.
Photo
Photo 50-1 
Photo
Photo 50-2 
51) Unit #4; The sink faucet was loose. Recommend that a qualified person repair as necessary.
Photo
Photo 51-1 
52) Unit #5; The oven light was inoperable. Recommend replacing bulb or that repairs are made, if necessary, by a qualified person.
53) One or more light bulbs were missing or inoperable in the range hood light fixture. The inspector was unable to determine if the light fixture was fully operable. Recommend replacing bulbs.
Photo
Photo 53-1 
Photo
Photo 53-2 
54)  Unit #1
Photo
Photo 54-1 
Photo
Photo 54-2 
Photo
Photo 54-3 
Photo
Photo 54-4 
Photo
Photo 54-5 
55)  Unit #2
Photo
Photo 55-1 
Photo
Photo 55-2 
Photo
Photo 55-3 
Photo
Photo 55-4 
Photo
Photo 55-5 
56)  Unit #3
Photo
Photo 56-1 
Photo
Photo 56-2 
Photo
Photo 56-3 
Photo
Photo 56-4 
57)  Unit #4
Photo
Photo 57-1 
Photo
Photo 57-2 
Photo
Photo 57-3 
Photo
Photo 57-4 
Photo
Photo 57-5 
58)  Unit #5
Photo
Photo 58-1 
Photo
Photo 58-2 
Photo
Photo 58-3 
Photo
Photo 58-4 
Photo
Photo 58-5 
59)  Unit #6
Photo
Photo 59-1 
Photo
Photo 59-2 
Photo
Photo 59-3 
Photo
Photo 59-4 
Photo
Photo 59-5 
Bathrooms, Laundry and SinksTable of contents
Limitations: The following items are not included in this inspection: overflow drains for tubs and sinks; heated towel racks, saunas, steam generators, clothes washers, clothes dryers. Any comments made regarding these items are as a courtesy only. Note that the inspector does not determine the adequacy of washing machine drain lines, washing machine catch pan drain lines, or clothes dryer exhaust ducts. The inspector does not operate water supply or shut-off valves for sinks, toilets, bidets, clothes washers, etc. due to the possibility of valves leaking or breaking when operated. The inspector does not determine if shower pans or tub and shower enclosures are water tight, or determine the completeness or operability of any gas piping to laundry appliances.
Unit #1: Full bath, basement
Unit #2: Full bath, first floor
Unit #3: Full bath, second floor
Unit #4: Full bath, second floor
Unit #5: Full bath, first floor
Unit #6: Full bath, basement
Condition of counters: Appeared serviceable
Condition of cabinets: Appeared serviceable, but required repair, replacement and/or evaluation (see comments below)
Condition of flooring: Appeared serviceable, but required repairs, replacement and/or evaluation (see comments below)
Condition of sinks and related plumbing: Appeared serviceable
Condition of toilets: Appeared serviceable
Condition of bathtubs and related plumbing: Appeared serviceable
Condition of shower(s) and related plumbing: Appeared serviceable
Condition of ventilation systems: Appeared serviceable, but required repairs, replacement and/or evaluation (see comments below)
Bathroom and laundry ventilation type: Spot exhaust fans, with individual ducts
Gas supply for laundry equipment present: No
240 volt receptacle for laundry equipment present: Yes
60) The clothes dryer was equipped with a vinyl or mylar, accordion-type, flexible exhaust duct and were long. The U.S. Consumer Product Safety Commission considers these types of ducts to be unsafe, and a fire hazard. They can trap lint and are susceptible to kinks or crushing, which can greatly reduce the air flow and cause overheating. Recommend that such ducts be replaced with a rigid or corrugated semi-rigid metal duct, and by a qualified contractor if necessary. For more information, visit:
http://www.reporthost.com/?DRYER
Photo
Photo 60-1 
Photo
Photo 60-2 
61) Conducive conditionsUnit #1 and 2; Flooring in bathrooms was damaged and/or substandard. Water can damage the the sub-floor as a result. Recommend that a qualified contractor replace or repair flooring as necessary.
Photo
Photo 61-1 
Photo
Photo 61-2 
62) Unit #5; The exhaust fan was inoperable. Moisture may accumulate and result in mold, bacteria or fungal growth. Recommend that a qualified person clean, repair or replace fans as necessary.
Photo
Photo 62-1 
63) Conducive conditionsUnit #1, 2 and 6; Caulk was missing around the base of the bathtub spout, or there was a gap behind it. Water may enter the wall structure behind the bathtub. Recommend that a qualified person repair as necessary to eliminate the gap. For example, by installing or replacing caulk if the gap is small enough. For larger gaps, a shorter spout nipple or an escutcheon plate can be installed.
Photo
Photo 63-1 
Photo
Photo 63-2 
64) Conducive conditionsUnits #2, 3 and 4; Gaps, no caulk, or substandard caulking were found between the bathtub and the floor and/or walls. Water may penetrate these areas and cause damage. Recommend that a qualified person re-caulk or install caulking as necessary.
Photo
Photo 64-1 
Photo
Photo 64-2 
Photo
Photo 64-3 
Photo
Photo 64-4 
65) Unit #2; Gaps, no caulk, or substandard caulking were found between countertops and backsplashes. Water can penetrate these areas and cause damage. Recommend that a qualified person repair as necessary. For example, by installing or replacing caulk.
Photo
Photo 65-1 
66) Unit #6; Cabinet hardware such as hinges, latches, closers, magnets or pulls were loose, missing or damaged at one or more cabinet drawers, doors or turntables. Recommend that a qualified person repair as necessary.
Photo
Photo 66-1 
67) Unit #6; The hot and/or cold water supply flow for the sink was low or inoperable. Recommend that a qualified person clean the aerator first, if that doesn't correct the problem then contact a plumber evaluate and repair as necessary.
Photo
Photo 67-1 
68) Units #4 and 5; The sinks drained slowly. Recommend clearing drain and/or having a qualified plumber repair if necessary.
Photo
Photo 68-1 
Photo
Photo 68-2 
69) Unit #2; Caulk around the base of the toilet was missing, substandard and/or deteriorated. Modern standards require caulk to be installed around the entire toilet base where it meets the floor for sanitary reasons. Without it, soiled water can soak into flooring and sub-floor materials if the toilet overflows. Condensation from the toilet can also soak into the flooring. Recommend that a qualified person caulk around toilet bases per standard building practices.
70) Unit #4; The sink was missing the stopper. Objects can plug the drain easily. Recommend a qualified person replace the stopper.
Photo
Photo 70-1 
71) Units #1 and 5; The bathtubs drained slowly. Recommend clearing drain and/or that a qualified plumber repair if necessary.
Photo
Photo 71-1 
Photo
Photo 71-2 
72)  Unit #1
Photo
Photo 72-1 
Photo
Photo 72-2 
Photo
Photo 72-3 
Photo
Photo 72-4 
Photo
Photo 72-5 
Photo
Photo 72-6 
Photo
Photo 72-7 
73)  Unit #2
Photo
Photo 73-1 
Photo
Photo 73-2 
Photo
Photo 73-3 
Photo
Photo 73-4 
Photo
Photo 73-5 
Photo
Photo 73-6 
74)  Unit #3
Photo
Photo 74-1 
Photo
Photo 74-2 
Photo
Photo 74-3 
Photo
Photo 74-4 
Photo
Photo 74-5 
Photo
Photo 74-6 
75)  Unit #4
Photo
Photo 75-1 
Photo
Photo 75-2 
Photo
Photo 75-3 
Photo
Photo 75-4 
Photo
Photo 75-5 
Photo
Photo 75-6 
76)  Unit #5
Photo
Photo 76-1 
Photo
Photo 76-2 
Photo
Photo 76-3 
Photo
Photo 76-4 
Photo
Photo 76-5 
Photo
Photo 76-6 
77)  Unit #6
Photo
Photo 77-1 
Photo
Photo 77-2 
Photo
Photo 77-3 
Photo
Photo 77-4 
Photo
Photo 77-5 
Photo
Photo 77-6 
Limitations: Structural components such as joists and beams, and other components such as piping, wiring and/or ducting that are obscured by under-floor insulation are also excluded from this inspection. Note that the inspector does not determine if support posts, columns, beams, joists, studs, trusses, etc. are of adequate size, spanning or spacing.

The inspector does not guarantee or warrant that water will not accumulate in the basement in the future. Access to the basement during all seasons and during prolonged periods of all types of weather conditions (e.g. heavy rain, melting snow) would be needed to do so. The inspector does not determine the adequacy of basement floor or stairwell drains, or determine if such drains are clear or clogged.

Note that all basement areas should be checked periodically for water intrusion, plumbing leaks and pest activity.
Limitations: The following items are not included in this inspection: generator systems, transfer switches, surge suppressors, inaccessible or concealed wiring; underground utilities and systems; low-voltage lighting or lighting on timers or sensors. Any comments made regarding these items are as a courtesy only. Note that the inspector does not determine the adequacy of grounding or bonding, if this system has an adequate capacity for the client's specific or anticipated needs, or if this system has any reserve capacity for additions or expansion. The inspector does not operate circuit breakers as part of the inspection, and does not install or change light bulbs. The inspector does not evaluate every wall switch or receptacle, but instead tests a representative number of them per various standards of practice. When furnishings, stored items or child-protective caps are present some receptacles are usually inaccessible and are not tested; these are excluded from this inspection. Receptacles that are not of standard 110 volt configuration, including 240-volt dryer receptacles, are not tested and are excluded. The functionality of, power source for and placement of smoke and carbon monoxide alarms is not determined as part of this inspection. Upon taking occupancy, proper operating and placement of smoke and carbon monoxide alarms should be verified and batteries should be changed. These devices have a limited lifespan and should be replaced every 10 years. The inspector attempts to locate and evaluate all main and sub-panels. However, panels are often concealed. If panels are found after the inspection, a qualified electrician should evaluate and repair if necessary. The inspector attempts to determine the overall electrical service size, but such estimates are not guaranteed because the overall capacity may be diminished by lesser-rated components in the system. Any repairs recommended should be made by a licensed electrician.
Electric service condition: Appeared serviceable
Primary service type: Overhead
Number of service conductors: 3
Service voltage (volts): 120-240
Estimated service amperage all units: 100
Primary service overload protection type: Circuit breakers
Service entrance conductor material: Stranded aluminum
Main disconnect rating (amps): 100
System ground: Not determined, not readily apparent
Condition of main service panel: Appeared serviceable
Location of service panel Unit #1: Bedroom closet
Location of service panel Unit #2: Laundry closet
Location of service panel Unit #3: Bedroom closet
Location of service panel Unit #4: Laundry closet
Location of service panel Unit #5: Laundry closet
Location of service panel Unit #6: Bedroom closet
Location of main disconnect: At main disconnect panel outside
Condition of branch circuit wiring: Serviceable
Branch circuit wiring type: non-metallic sheathed, aluminum multi-strand
Solid strand aluminum branch circuit wiring present: None visible
Ground fault circuit interrupter (GFCI) protection present: Yes, but required repairs, replacement and or evaluation (see comments below)
Arc fault circuit interrupter (AFCI) protection present: No
Smoke alarms installed: Yes, but not tested
Carbon monoxide alarms installed: Yes, but not tested
78) Units #4 and 6; One or more ground fault circuit interrupter (GFCI) circuit breakers in panel(s) wouldn't trip when tested. GFCI breakers reduce the chance of shock when using equipment in wet areas. This is a potential shock hazard. Recommend that a qualified electrician evaluate and repair as necessary.
Photo
Photo 78-1 
Photo
Photo 78-2 
79) One or more electric receptacles at the kitchen, full bath and/or exterior had no visible ground fault circuit interrupter (GFCI) protection, or the inspector was unable to determine if GFCI protection was present. If not GFCI-protected, receptacles in wet areas pose a shock hazard. Recommend that a qualified electrician evaluate and install GFCI protection if necessary and per standard building practices. General guidelines for GFCI-protected receptacles include the following locations:
  • Outdoors (since 1973)
  • Bathrooms (since 1975)
  • Garages (since 1978)
  • Kitchens (since 1987)
  • Crawl spaces and unfinished basements (since 1990)
  • Wet bar sinks (since 1993)
  • Laundry and utility sinks (since 2005)
For more information, visit:
http://www.reporthost.com/?GFCI

Unit #3
Photo
Photo 79-1 
Photo
Photo 79-2 
Photo
Photo 79-3 
Photo
Photo 79-4 
Photo
Photo 79-5 
Photo
Photo 79-6 
Photo
Photo 79-7 
80) One or more wall switches were scorched. The wiring for these switches may be damaged due to overheating. Recommend that a qualified electrician replace such switches, evaluate related wiring and repair if necessary.
Photo
Photo 80-1 
81) Unit #5; One or more circuit breakers were "double tapped," where two or more wires were installed in the breaker's lug. Most breakers are designed for only one wire to be connected. This is a safety hazard since the lug bolt can tighten securely against one wire but leave other(s) loose. Arcing, sparks and fires can result. Recommend that a qualified electrician repair as necessary. For more information, visit:
http://www.reporthost.com/?DBLTAP
Photo
Photo 81-1 
82) Unit #2; One or more electric receptacles and/or the boxes in which they were installed were loose and/or not securely anchored. Wire conductors can be damaged due to repeated movement and/or tension on wires, or insulation can be damaged. This is a shock and fire hazard. Recommend that a qualified electrician repair as necessary.
Photo
Photo 82-1 
83) More than one unit; One or more receptacles were installed directly above electric baseboard heaters. This was a common practice in the past, but insulation on appliance cords in contact with the heater(s) can be damaged by heaters. This is a shock and fire hazard. Recommend that a qualified electrician make repairs or modifications as necessary. For example, by converting receptacles to junction boxes, moving receptacles and/or moving baseboard heaters.
Photo
Photo 83-1 
Photo
Photo 83-2 
84) Unit # 3; One or more electric receptacles were incorrectly wired with an open neutral. Recommend that a qualified electrician repair as necessary.
Photo
Photo 84-1 
85) One or more light fixtures were missing. This is a safety hazard. Recommend that a qualified electrician repair or replace light fixtures as necessary.
Photo
Photo 85-1 
86) The main electrical meter base was loose. This is a safety hazard. Recommend a qualified electrician tighten or repair the meter panel.
Photo
Photo 86-1 
Photo
Photo 86-2 
87) Unit #5; When the kitchen light switch was in the off position more than one outlet and or light switch was inoperable. This can be a safety hazard. Recommend contacting a qualified electrician to repair.
Photo
Photo 87-1 
88) Unit #4; One or more wires inside the panel(s) was burnt or loose. This poses a safety hazard for shock and/or fire. Recommend that a qualified electrician repair as necessary.
Photo
Photo 88-1 
89) One or more cover plates for switches, receptacles or junction boxes were missing or broken. These plates are intended to contain fire and prevent electric shock from occurring due to exposed wires. Recommend that a qualified person install cover plates where necessary.
Photo
Photo 89-1 
Photo
Photo 89-2 
Photo
Photo 89-3 
Photo
Photo 89-4 
90) Branch circuit wiring installed in buildings built prior to the mid 1980s is typically rated for a maximum temperature of only 60 degrees Celsius. This includes non-metallic sheathed (Romex) wiring, and both BX and AC metal-clad flexible wiring. Knob and tube wiring, typically installed in homes built prior to 1950, may be rated for even lower maximum temperatures. Newer electric fixtures including lighting and fans typically require wiring rated for 90 degrees Celsius. Connecting newer fixtures to older, 60-degree-rated wiring is a potential fire hazard. Repairs for such conditions may involve replacing the last few feet of wiring to newer fixtures with new 90-degree-rated wire, and installing a junction box to join the old and new wiring.

It is beyond the scope of this inspection to determine if such incompatible components are installed, or to determine the extent to which they're installed. Based on the age of this building, the client should be aware of this safety hazard, both for existing fixtures and when planning to upgrade with newer fixtures. Consult with a qualified electrician for repairs as necessary.
91) One or more globes or covers for light fixtures were missing or damaged. Recommend replacing as necessary to avoid exposed bulbs. With closet lighting or where flammable stored objects are near light fixtures, missing or broken covers can be a fire hazard.
Photo
Photo 91-1 
Photo
Photo 91-2 
Photo
Photo 91-3 
Photo
Photo 91-4 
Photo
Photo 91-5 
Photo
Photo 91-6 
92) One or more light fixtures were inoperable (didn't turn on when nearby switches were operated). Recommend further evaluation by replacing bulbs and/or consulting with the property owner. If replacing bulbs doesn't work and/or no other switch(es) can be found, then recommend that a qualified electrician evaluate and repair or replace light fixtures as necessary.
Photo
Photo 92-1 
93) All Units; The inspector does not verify that the legend(s) for circuit breakers or fuses in panel(s) was accurate, complete, legible or may be confusing. This is a potential shock or fire hazard in the event of an emergency when power needs to be turned off. Recommend having a qualified person verify the legend(s) so it's accurate, complete and legible. Evaluation by a qualified electrician may be necessary.
Photo
Photo 93-1 
Photo
Photo 93-2 
94)  Electric; Main meter base and disconnects for each unit
Photo
Photo 94-1 
Photo
Photo 94-2 
Photo
Photo 94-3 100 amp main disconnects for each unit on each side of the meter base
95)  Unit #1
Photo
Photo 95-1 
Photo
Photo 95-2 
96)  Unit #2
Photo
Photo 96-1 
Photo
Photo 96-2 
97)  Unit #3
Photo
Photo 97-1 
Photo
Photo 97-2 
98)  Unit #4
Photo
Photo 98-1 
Photo
Photo 98-2 
99)  Unit #5
Photo
Photo 99-1 
Photo
Photo 99-2 
100)  Unit #6
Photo
Photo 100-1 
Photo
Photo 100-2 
Heating, Ventilation and Air Condition (HVAC)Table of contents
Limitations: The following items are not included in this inspection: humidifiers, dehumidifiers, electronic air filters; solar, coal or wood-fired heat systems; thermostat or temperature control accuracy and timed functions; heating components concealed within the building structure or in inaccessible areas; underground utilities and systems; safety devices and controls (due to automatic operation). Any comments made regarding these items are as a courtesy only. Note that the inspector does not provide an estimate of remaining life on heating or cooling system components, does not determine if heating or cooling systems are appropriately sized, does not test coolant pressure, or perform any evaluations that require a pilot light to be lit, a shut-off valve to be operated, a circuit breaker to be turned "on" or a serviceman's or oil emergency switch to be operated. It is beyond the scope of this inspection to determine if furnace heat exchangers are intact and free of leaks. Condensation pans and drain lines may clog or leak at any time and should be monitored while in operation in the future. Where buildings contain furnishings or stored items, the inspector may not be able to verify that a heat source is present in all "liveable" rooms (e.g. bedrooms, kitchens and living/dining rooms).
General heating system type(s): Electric heaters
General heating distribution type(s): None, individual heaters
Last service date of primary heat source: Unknown
Condition of electric heaters (not forced air): More than one heater required repairs and or replacement
Electric heater type (not forced air): Wall mounted baseboard
Condition of controls: Appeared serviceable, but required repair, replacement and/or evaluation (see comments below)
101) Several electric baseboard heaters in more than one unit were inoperable, had control knobs missing or not working and/or were damaged. This is a potential safety hazard. Recommend that a qualified electrician repair or replace as necessary.
Photo
Photo 101-1 
Photo
Photo 101-2 
Photo
Photo 101-3 
Photo
Photo 101-4 
Photo
Photo 101-5 
Photo
Photo 101-6 
Photo
Photo 101-7 
102) The primary heating system for this home was powered by electricity, and the electric service to the home appeared to be rated at less than 200 amps. A 200 amp service is typically installed to provide adequate power for all-electric heat. Recommend consulting with a qualified electrician about upgrading the electric service. Note that the electric service's rating is based on the lowest rating for the meter base, the service conductors, the main service panel and the main disconnect switch. One or more of these components may need replacing to upgrade.
103)  Baseboard heaters and wall thermostats
Photo
Photo 103-1 
Photo
Photo 103-2 
Plumbing / Fuel SystemsTable of contents
Limitations: The following items are not included in this inspection: private/shared wells and related equipment; private sewage disposal systems; hot tubs or spas; main, side and lateral sewer lines; gray water systems; pressure boosting systems; trap primers; incinerating or composting toilets; fire suppression systems; water softeners, conditioners or filtering systems; plumbing components concealed within the foundation or building structure, or in inaccessible areas such as below tubs; underground utilities and systems; overflow drains for tubs and sinks; backflow prevention devices. Any comments made regarding these items are as a courtesy only. Note that the inspector does not operate water supply or shut-off valves due to the possibility of valves leaking or breaking when operated. The inspector does not test for lead in the water supply, the water pipes or solder, does not determine if plumbing and fuel lines are adequately sized, and does not determine the existence or condition of underground or above-ground fuel tanks.
Condition of service and main line: Appeared serviceable
Water service: Public
Location of main water shut-off: Under bathroom sink, Unit #6
Condition of supply lines: Appeared serviceable
Supply pipe material: Copper, Galvanized steel
Condition of drain pipes: Appeared serviceable
Drain pipe material: Plastic
Condition of waste lines: Appeared serviceable
Waste pipe material: Plastic
Vent pipe condition: Appeared serviceable
Vent pipe material: Plastic
Sump pump installed: None visible
Visible fuel storage systems: None visible
104) Copper water supply pipes were installed. Copper pipes installed prior to the late 1980s may be joined with solder that contains lead, which is a known health hazard especially for children. Laws were passed in 1985 prohibiting the use of lead in solder, but prior to that solder normally contained approximately 50% lead. The client should be aware of this, especially if children will be using this water supply system. Note that the inspector does not test for toxic materials such as lead. The client should consider having a qualified lab test for lead, and if necessary take steps to reduce or remove lead from the water supply. Various solutions include:
  • Flush water taps or faucets. Do not drink water that has been sitting in the plumbing lines for more than 6 hours
  • Install appropriate filters at points of use
  • Use only cold water for cooking and drinking, as hot water dissolves lead more quickly than cold water
  • Use bottled or distilled water
  • Treat well water to make it less corrosive
  • Have a qualified plumber replace supply pipes and/or plumbing components as necessary
For more information visit:
http://www.reporthost.com/?LEADDW
http://www.reporthost.com/?LEAD
105) Based on visible components or information provided to the inspector, this property appeared to have a private sewage disposal (septic) and alarm system. These are specialty systems and are excluded from this inspection. Comments in this report related to this system are made as a courtesy only and are not meant to be a substitute for a full evaluation by a qualified specialist. Generally, septic tanks should be pumped and inspected every 3 years. Depending on the type of system and municipal regulations, inspection and maintenance may be required more frequently, often annually. Recommend the following:
  • Consult with the property owner about this system's maintenance and repair history
  • Review any documentation available for this system
  • Review inspection and maintenance requirements for this system
  • That a qualified specialist evaluate, perform maintenance and make repairs if necessary
For more information, visit:
http://www.reporthost.com/?SEPTIC
Photo
Photo 105-1 
Photo
Photo 105-2 
106)  Plumbing
Photo
Photo 106-1 
Photo
Photo 106-2 
Photo
Photo 106-3 
Photo
Photo 106-4 
Photo
Photo 106-5 Water meter and main valve
Water HeaterTable of contents
Limitations: Evaluation of and determining the adequacy or completeness of the following items are not included in this inspection: water recirculation pumps; solar water heating systems; Energy Smart or energy saver controls; catch pan drains. Any comments made regarding these items are as a courtesy only. Note that the inspector does not provide an estimate of remaining life on water heaters, does not determine if water heaters are appropriately sized, or perform any evaluations that require a pilot light to be lit or a shut-off valve to be operated.
Condition of water heater: Appeared serviceable, but all units required repair, replacement and/or evaluation (see comments below)
Type: Tank
Energy source: Electricity
Capacity (in gallons): 40 & 50
Temperature-pressure relief valve installed: Yes
Location of water heater: Laundry or bedroom closets
Hot water temperature tested: Yes
Water temperature (degrees Fahrenheit): Unit #1 114.1, Unit #2 119.8, Unit #3 120.1, Unit #4 131.7, Unit #5 114.1, Unit #6 136.5
107) All Units; The water heater did not have earthquake straps or struts installed. This is a potential safety hazard in the event of an earthquake due to the risk of the water heater tipping over, gas lines breaking if it's gas-fired, or electric wiring being damaged if powered by electricity. Leaks can also occur in water-supply pipes. Recommend that a qualified person install earthquake straps or struts as necessary and per standard building practices.
108) No drain line was installed for the temperature-pressure relief valve. This is a potential safety hazard due to the risk of scalding if someone is standing next to the water heater when the valve opens. Recommend that a qualified plumber install a drain line per standard building practices.
Photo
Photo 108-1 
Photo
Photo 108-2 
109) All Units; Wiring for the water heater's power supply was exposed and subject to damage. Standard building practices call for non-metallic sheathed wiring to be protected with BX armored conduit to prevent damage. This is a potential safety hazard for shock. Recommend that a qualified contractor repair per standard building practices.
Photo
Photo 109-1 
Photo
Photo 109-2 
Photo
Photo 109-3 
Photo
Photo 109-4 
Photo
Photo 109-5 
Photo
Photo 109-6 
110) Units #4 and 6; The hot water temperature was greater than 120 degrees Fahrenheit. This is a safety hazard due to the risk of scalding. The thermostat should be adjusted so the water temperature doesn't exceed 120 degrees. If the water heater is powered by electricity, a qualified person should perform the adjustment, since covers that expose energized equipment normally need to be removed. For more information on scalding dangers, visit:
http://www.reporthost.com/?SCALD
111) Unit #5, 6; Significant corrosion or rust was found on the water heater tank casing. This is an indication that the water heater is near or at the end of its service life. At a minimum, monitor this water heater and budget for a replacement in the near future. Consider replacing the water heater now before any leaks occur. Significant flooding can occur if the water heater does fail.
Photo
Photo 111-1 
Photo
Photo 111-2 
112) All Units; The estimated useful life for most water heaters is 8-12 years. These water heater appeared to be at and/or beyond this age and/or its useful lifespan and may need replacing at any time. Recommend budgeting for a replacement in the near future, or considering replacement now before any leaks occur. The client should be aware that significant flooding can occur if the water heater fails. If not replaced now, consider having a qualified person install a catch pan and drain or a water alarm to help prevent damage if water does leak.
113)  Unit #1 approx. 8 yrs. old
Photo
Photo 113-1 
Photo
Photo 113-2 
114)  Unit #2 approx. 9 yrs. old
Photo
Photo 114-1 
Photo
Photo 114-2 
115)  Unit #3 approx. 13 yrs. old
Photo
Photo 115-1 
Photo
Photo 115-2 
116)  Unit #4 approx. 7 yrs. old
Photo
Photo 116-1 
Photo
Photo 116-2 
117)  Unit #5 approx. 17 yrs. old
Photo
Photo 117-1 
Photo
Photo 117-2 
118)  Unit #6 approx. 16 yrs. old
Photo
Photo 118-1 
Photo
Photo 118-2 
Attic and Roof StructureTable of contents
Limitations: The following items or areas are not included in this inspection: areas that could not be traversed or viewed clearly due to lack of access; areas and components obscured by insulation. Any comments made regarding these items are made as a courtesy only. The inspector does not determine the adequacy of the attic ventilation system. Complete access to all roof and attic spaces during all seasons and during prolonged periods of all types of weather conditions (e.g. high/low temperatures, high/low humidity, high wind and rain, melting snow) would be needed to do so. The inspector is not a licensed engineer and does not determine the adequacy of roof structure components such as trusses, rafters or ceiling beams, or their spacing or sizing.
Attic inspection method: Not inspected because no access was found
Condition of roof ventilation: Required repair, replacement and/or evaluation (see comments below)
Roof ventilation type: Box vents (roof jacks), Enclosed soffit vents
119) Conducive conditionsOne or more sections of the roof structure appeared to have substandard ventilation, soffit or lower vents were missing. This can result in high attic and roof surface temperatures, reduce the life of the roof covering materials, and/or increase cooling costs. High levels of moisture are also likely to accumulate in the roof structure or attic, and can be a conducive condition for wood-destroying organisms. Standard building practices require one free square foot of ventilation for every 150 square feet of attic space, and that vents be evenly distributed between the lowest points of the roof structure and the highest points to promote air circulation. Often this means that both soffit vents and ridge or gable end vents are installed. Recommend that a qualified contractor evaluate and repair per standard building practices.
Photo
Photo 119-1 
120) No accessible attic spaces were found or inspected at this property. The inspector attempts to locate attic access points and evaluate attic spaces where possible. When a home is occupied, such access points may be obscured by stored items or furnishings. Home inspection standards of practice do not require inspectors to move stored items, furnishings or personal belongings. If such access points are found in the future and/or made accessible, a qualified person should fully evaluate those attic spaces and roof structures.
Wood Destroying Organism FindingsTable of contents
Limitations: This report only includes findings from accessible and visible areas on the day of the inspection. In addition to the inaccessible areas documented in this report, examples of other inaccessible areas include: sub areas less than 18 inches in height; attic areas less than 5 feet in height, areas blocked by ducts, pipes or insulation; areas where locks or permanently attached covers prevent access; areas where insulation would be damaged if traversed; areas obscured by vegetation. All inaccessible areas are subject to infestation or damage from wood-destroying organisms. The inspector does not move furnishings, stored items, debris, floor or wall coverings, insulation, or other materials as part of the inspection, nor perform destructive testing. Wood-destroying organisms may infest, re-infest or become active at any time. No warranty is provided as part of this inspection.

Scope of the Inspection:

The scope of the inspection is strictly limited as set forth in the Pre-Inspection Agreement. The parties understand and agree BEFORE any inspection takes place that the inspection will be of readily accessible areas of the building to be inspected and is limited to visual observations of apparent conditions existing at the time of the inspection only. Latent and concealed defects and deficiencies, including but not limited to, basement flooring, basement seepage and roof leakage, inaccessible attic spaces do to a verity of reasons, are Excluded from the inspection. The parties agree in advance that the American Society of Home Inspectors (ASHI) Standards of Practice, most current edition, shall define the standard duty and the conditions, limitations, and exclusions of the inspection and are incorporated by reference herein. Refer to the signed Pre-Inspection Agreement for further limitations, exclusions and liabilities.

You are encouraged to read the entire report, not just summery sections. The whole and complete report is all pertinent information in the inspection. Please read and carefully consider all the information comprised in the Final Report.

I sincerely hope that the information in this report is useful and helpful to you, in giving a more in depth awareness of the current condition of the property that has just been inspected.

Again, Thank-You for choosing HHI-Hews Home Inspection, its been a pleasure serving you.