This report published on Thursday, February 27, 2020 9:27:32 AM EST
This report is the exclusive property of this inspection company and the client(s) listed in the report title. Use of this report by any unauthorized persons is prohibited.
How to Read this Report
This report is organized by the property's functional areas. Within each functional area, descriptive information is listed first and is shown in bold type. Items of concern follow descriptive information.
Concerns are shown and sorted according to these types:
Safety
Poses a safety hazard
Repair/Replace
Recommend repairing or replacing
Repair/Maintain
Recommend repair and/or maintenance
Maintain
Recommend ongoing maintenance
Evaluate
Recommend evaluation by a specialist
Comment
For your information
Click here for a glossary of building construction terms.Contact your inspector If there are terms that you do not understand, or visit the glossary of construction terms at https://www.reporthost.com/glossary.asp
Client present for discussion at end of inspection: Yes
Weather conditions during inspection: Dry (no rain)
Temperature during inspection: Cool
Inspection fee: $385
Payment method: Electronic
Type of building: Single family
Buildings inspected: One house
Number of residential units inspected: 1
Age of main building: 2007 13 years old
Source for main building age: Municipal records or property listing
Front of building faces: North
Main entrance faces: North
Occupied: No
1) Microbial growths were found at one or more locations in Deck. It is beyond the scope of this inspection to identify what substance or organism this staining is. However such staining is normally caused by excessively moist conditions, which in turn can be caused by plumbing or building envelope leaks and/or substandard ventilation. These conducive conditions should be corrected before making any attempts to remove or correct the staining. Normally affected materials such as drywall are removed, enclosed affected spaces are allowed to dry thoroughly, a mildewcide may be applied, and only then is drywall reinstalled. For evaluation and possible mitigation, consult with a qualified industrial hygienist or mold/moisture mitigation specialist. For more information, visit: http://www.reporthost.com/?MOLDCDC http://www.reporthost.com/?MOLDEPA
Microbial growth was found on back wooden deck.
Photo 1-1 Photo 1-2
Photo 1-3 Photo 1-4
Photo 1-5
2) The water service was not turned on during the inspection. The inspector operates only "normal" controls such as faucets, and does not operate shut-off valves to the water meter or house. As a result, plumbing supply, drain waste and vent lines, traps, pumps, fixtures, and some appliances such as water heaters weren't fully evaluated. The water pressure was not determined. Recommend that a qualified person make a full evaluation of the plumbing system after the water supply is turned back on. Areas below the house should be evaluated after plumbing has been operated to check for leaks. Any problems that are found after this evaluation should be repaired by a qualified plumber.
Condition of sidewalks and/or patios: Appeared serviceable
Sidewalk material: Poured in place concrete
Condition of deck, patio and/or porch covers: Appeared serviceable, Required repairs, replacement and/or evaluation (see comments below)
Deck, patio, porch cover material and type: Open
Condition of decks, porches and/or balconies: Appeared serviceable, Required repairs, replacement and/or evaluation (see comments below)
Deck, porch and/or balcony material: Wood
Condition of stairs, handrails and guardrails: Appeared serviceable, Required repairs, replacement and/or evaluation (see comments below)
Exterior stair material: Wood
3) Fungal rot was found in decking boards, joists and/or beams at one or more decks or porches. Recommend that a qualified contractor evaluate and repair as necessary. All rotten wood should be replaced.
Photo 3-1 Photo 3-2
Photo 3-3 Photo 3-4
Photo 3-5 Photo 3-6
4) Fungal rot was found in support posts, beams and/or lattice boards at one or more structures covering decks, patios and/or porches. Recommend that a qualified person repair as necessary. All rotten wood should be replaced.
Photo 4-1 Photo 4-2
Photo 4-3 Photo 4-4
5) Wooden deck or porch surfaces and/or railings were overdue for normal maintenance. Recommend that a qualified person clean and preserve as necessary. Where decks have been coated with a finish such as opaque stains or paint, it may be too difficult to strip the finish and apply anything but paint or opaque stain. Where transparent stain or penetrating oil has been applied in the past, recommend that a penetrating oil be used. For more information, visit: http://www.reporthost.com/?PENOIL http://www.reporthost.com/?DKMAIN
Photo 5-1 Photo 5-2
Photo 5-3 Photo 5-4
6) Minor deterioration (e.g. cracks, holes, settlement, heaving) was found in the driveway, but no trip hazards were found. The client may wish to have repairs made for cosmetic reasons.
Photo 6-1 Photo 6-2
Photo 6-3 Photo 6-4
Photo 6-5 Photo 6-6
7) Minor deterioration (e.g. cracks, holes, settlement, heaving) was found in sidewalks or patios, but no trip hazards were found. The client may wish to have repairs made for cosmetic reasons.
Condition of wall exterior covering: Appeared serviceable
Apparent wall structure: Brick
Wall covering: Wood
Condition of foundation and footings: Appeared serviceable
Apparent foundation type: Finished basement
Foundation/stem wall material: Concrete block
Footing material (under foundation stem wall): Poured in place concrete
9) Caulk was in some areas. For example, around doors. Recommend that a qualified person renew or install caulk as necessary. Where gaps are wider than 1/4 inch, an appropriate material other than caulk should be used. For more information, visit: http://www.reporthost.com/?CAULK
Condition of exterior entry doors: Appeared serviceable
Exterior door material: Wood
Condition of floor substructure above: Appeared serviceable
Pier or support post material: Wood, Concrete
Floor structure above: Solid wood joists
Condition of insulation underneath floor above: Appeared serviceable
Insulation material underneath floor above: Fiberglass roll or batt
10) Handrails at one or more flights of stairs were loose and/or wobbly. This is a safety hazard. Recommend that a qualified person repair as necessary.
Limitations: The following items or areas are not included in this inspection: areas that could not be traversed or viewed clearly due to lack of access; areas and components obscured by insulation. Any comments made regarding these items are made as a courtesy only. The inspector does not determine the adequacy of the attic ventilation system. Complete access to all roof and attic spaces during all seasons and during prolonged periods of all types of weather conditions (e.g. high/low temperatures, high/low humidity, high wind and rain, melting snow) would be needed to do so. The inspector is not a licensed engineer and does not determine the adequacy of roof structure components such as trusses, rafters or ceiling beams, or their spacing or sizing.
Attic inspection method: Viewed from hatch(es)
Condition of roof structure: Appeared serviceable
Roof structure type: Trusses, Rafters
Ceiling structure: Trusses
Condition of insulation in attic (ceiling, skylight chase, etc.): Appeared serviceable
Ceiling insulation material: Fiberglass roll or batt
Vermiculite insulation present: Yes
Vapor retarder: Installed
Condition of roof ventilation: Appeared serviceable
Condition of door between garage and house: Appeared serviceable
Type of door between garage and house: Wood
Condition of garage vehicle door(s): Appeared serviceable
Type of garage vehicle door: Sectional
Number of vehicle doors: 2
Condition of automatic opener(s): Appeared serviceable
Mechanical auto-reverse operable (reverses when meeting reasonable resistance during closing): Yes
Condition of garage floor: Appeared serviceable
Condition of garage interior: Appeared serviceable
Garage ventilation: Exists
11) The step(s) installed below the door between the garage and the house were . This is a fall or trip hazard. A qualified person should repair as necessary.
According to code, the height of those stairs entering the home require a handrail
Photo 11-1 Photo 11-2
12) Minor cracks were found in the concrete slab floor. These are common and appeared to be only a cosmetic issue.
Condition of service and main line: Appeared serviceable
Water service: Public
Location of main water shut-off: Basement, In mechanical room
Condition of supply lines: Appeared serviceable
Supply pipe material: Copper, Galvanized steel
Condition of drain pipes: Appeared serviceable
Drain pipe material: Plastic, Galvanized steel
Condition of waste lines: Appeared serviceable
Waste pipe material: Plastic, Galvanized steel
Vent pipe condition: Appeared serviceable
Vent pipe material: Plastic, Galvanized steel
Sump pump installed: Yes
Condition of sump pump: Appeared serviceable
Sewage ejector pump installed: Yes
Condition of sewage ejector pump: Appeared serviceable
Type of irrigation system supply source: Public
Condition of fuel system: Appeared serviceable
Visible fuel storage systems: Below ground
Location of main fuel shut-off valve: At gas meter
13) This home was winterized. Typically this means the following:
The water supply has been turned off at the meter or main shut-off valve
The water supply to fixtures such as sinks, toilets, tubs and showers have been turned off at local shut-off valves
Sink drain traps and toilet bowls have been filled with anti-freeze
The water and power or fuel supplies to the water heater have been turned off
"De-winterizing" a home is not part of a home inspection. The inspector does not operate shut-off valves, meter valves, circuit breakers, or light pilot lights. This significantly limits the ability of the inspector to evaluate various systems and components such as plumbing fixtures, supply/drain/waste/vent lines and the water heater. They are excluded from this inspection. Recommend when the home has been completely de-winterized that a qualified person fully evaluate them.
14) The water supply to some plumbing system fixtures and/or appliances appeared to be shut off during the inspection and these were not fully evaluated. They are excluded from the inspection.
Water was turned off during the time of the Inspection, but still no evidence of past leaks or water damage
15) A sump pump was installed in the basement. These are specialty systems and only a limited evaluation was performed as part of this inspection. The inspector does not determine the adequacy of sump pumps and their associated drainage systems. The presence of a sump pump may indicate that water routinely accumulates below or inside the structure. Recommend asking the property owner how often the sump pump operates and for how long at different times of the year. The client should be aware that the service life of most sump pumps is 5-7 years, and that the pump may need replacing soon depending on its age and how often it operates.
16) The estimated useful life for most water heaters is 8-12 years. This water heater appeared to be this age and/or its useful lifespan and may need replacing at any time. Recommend budgeting for a replacement in the near future, or considering replacement now before any leaks occur. The client should be aware that significant flooding can occur if the water heater fails. If not replaced now, consider having a qualified person install a catch pan and drain or a water alarm to help prevent damage if water does leak.
The water heater seemed fine, but everything has a shelf life. And the estimated time for a water heater is 8-12years. This water heater was built 2012
Condition of sinks and related plumbing: Appeared serviceable, Not determined (water supply off, obscured by stored items, etc.)
Condition of toilets: Appeared serviceable, Not determined (water supply off, obscured by stored items, etc.)
Condition of bathtubs and related plumbing: Appeared serviceable, Not determined (water supply off, obscured by stored items, etc.)
Condition of shower(s) and related plumbing: Appeared serviceable, Not determined (water supply off, obscured by stored items, etc.)
Condition of ventilation systems: Appeared serviceable
Bathroom and laundry ventilation type: Central exhaust fan
Gas supply for laundry equipment present: Yes
240 volt receptacle for laundry equipment present: Yes
17) Water was turned off during the time of the Inspection, but still no evidence of past leaks or water damage throughout any of the bathroom sinks, bathtubs, shower heads, toilets, walls or ceilings
Condition of exterior entry doors: Appeared serviceable
Exterior door material: Wood
Condition of interior doors: Appeared serviceable
Condition of windows and skylights: Appeared serviceable
Type(s) of windows: Multi-pane, Single-pane
Condition of walls and ceilings: Appeared serviceable
Wall type or covering: Drywall
Ceiling type or covering: Drywall
Condition of flooring: Appeared serviceable
Condition of concrete slab floor(s): Appeared serviceable
Flooring type or covering: Carpet, Wood or wood products
Condition of stairs, handrails and guardrails: Appeared serviceable
18) Squeaking or creaking noises occur when walking on one or more sections of flooring. This is usually caused by substandard construction practices where the sub-floor decking is not adequately fastened to the framing below. For example, not enough glue was used and/or nails were used rather than screws. In most cases, this is only an annoyance rather than a structural problem. Various solutions such as Squeeeeek No More and Counter Snap fasteners exist to correct this. Repairs to eliminate the squeaks or creaks may be more or less difficult depending on the floor covering and the access to the underside of the sub-floor. Recommend that a qualified contractor evaluate and repair as necessary. For more information, visit: http://www.reporthost.com/?SQUEAK
Photo 18-1 Photo 18-2
Photo 18-3 Photo 18-4
Photo 18-5 Photo 18-6
Photo 18-7 Photo 18-8
19) Floors in the master bedroom had pop ups in the carpet and a couple of dead spots in the floor making it a bit squeaky
Visible evidence of active wood-destroying insects: Yes
Visible evidence of active wood decay fungi: Yes
Visible evidence of past wood-destroying insects: Yes
Visible evidence of past wood decay fungi: Yes
Visible evidence of damage by wood-destroying insects: Yes
Visible evidence of damage by wood decay fungi: Yes
Visible evidence of conditions conducive to wood-destroying organisms: Yes
Evidence of prior treatment of wood-destroying insects: Termite wood decay and Holes in wooden structures along the windows in the garage and also the room to the right of main entrance front door.
20) Evidence of active and/or past infestation of drywood termites was found at location(s) # in the form of with . Recommend the following:
Correct any conducive conditions for wood-destroying organisms mentioned in this report.
Consult with the property owner about any history of infestation.
Have a state-licensed pest control operator evaluate further and treat as necessary.
Photo 20-1 Photo 20-2
Photo 20-3 Photo 20-4
Photo 20-5 Photo 20-6
Photo 20-7
21) Termite wood decay and Holes in wooden structures along the windows in the garage and also the room to the right of main entrance front door. Didn’t see any evidence of termites on the back wooden deck, but without treatment, that is a main spot for termites