This report published on Friday, January 5, 2024 4:05:11 PM EST
This report is the exclusive property of this inspection company and the client(s) listed in the report title. Use of this report by any unauthorized persons is prohibited.
How to Read this Report
This report is organized by the property's functional areas. Within each functional area, descriptive information is listed first and is shown in bold type. Items of concern follow descriptive information.
Concerns are shown and sorted according to these types:
Safety
Poses a safety hazard
Major Defect
Correction likely involves a significant expense
Repair/Replace
Recommend repairing or replacing
Repair/Maintain
Recommend repair and/or maintenance
Minor Defect
Correction likely involves only a minor expense
Maintain
Recommend ongoing maintenance
Evaluate
Recommend evaluation by a specialist
Comment
For your information
Infestation
Evidence of infestation of wood destroying insects or organisms (Live or dead insect bodies, fungal growth, etc.)
Conducive conditions
Conditions conducive for wood destroying insects or organisms (Wood-soil contact, shrubs in contact with siding, roof or plumbing leaks, etc.)
Click here for a glossary of building construction terms.Contact your inspector If there are terms that you do not understand, or visit the glossary of construction terms at https://www.reporthost.com/glossary.asp
Client present for discussion at end of inspection: Yes
Weather conditions during inspection: Dry (no rain)
Temperature during inspection: Warm
Inspection fee: 325.00
Payment method: ZELLE
Type of building: Single family, Multiplex
Buildings inspected: One house
Number of residential units inspected: 1
Age of main building: 19954
Source for main building age: Municipal records or property listing
Front of building faces: East
Main entrance faces: East
Occupied: No
1) Based on substandard construction observed, modifications to this property may have been made without the owner having attained permits or inspections from the municipality. Work may have been performed by someone other than a qualified contractor or person. Consult with the property owner about this, and if necessary research permits.
At worst case, if substantial work was performed without permits, this knowledge must be disclosed when the building is sold in the future. This can adversely affect future sales. Also, the local municipality could require costly alterations to bring the building into legal compliance or even require that the additions or modifications be removed.
THE SEPTIC TANK WAS FULL OF HUMAN WASTE. Unknown if residence was converted to City sewer or of septic tanks were removed.
THE GARAGE WAS CONVERTED INTO A ROOM.
Cost estimate: $125.00 Service call
Photo 1-1 It is unclear whether the septic system was converted to the City of Hollywood sewer system or not. Verification is needed to confirm the same. Photo 1-2 It is unclear whether the septic system was converted to the City of Hollywood sewer system or not. Verification is needed to confirm the same.
Photo 1-3 It is unclear whether the septic system was converted to the City of Hollywood sewer system. Verification is needed to confirm the same. Unscrewed sewer caps had large amounts of human waste, flies, and foul order. Septic must be pumped and cleaned before making occupancy to the residence. Photo 1-4 The garage was converted into a room
2) Structures built prior to the mid 1980s may contain lead and/or asbestos. Lead is commonly found in paint and in some plumbing components. The EPA does not recognize newer coats of paint as encapsulating older coats of lead-based paint. Asbestos is commonly found in various building materials such as insulation, siding, and/or floor and ceiling tiles. Laws were passed in 1978 to prohibit usage of lead and asbestos, but stocks of materials containing these substances remained in use for a number of years thereafter. Both lead and asbestos are known health hazards. Evaluating for the presence of lead and/or asbestos is beyond the scope of this inspection. Any mention of these materials in this report is made as a courtesy only, and meant to refer the client to a specialist. Consult with specialists as necessary, such as industrial hygienists, professional labs and/or abatement specialists for this type of evaluation. For information on lead, asbestos and other hazardous materials in homes, visit: http://www.reporthost.com/?EPA http://www.reporthost.com/?CPSC http://www.reporthost.com/?CDC
Limitations: Unless specifically included in the inspection, the following items and any related equipment, controls, electric systems and/or plumbing systems are excluded from this inspection: detached buildings or structures; fences and gates; retaining walls; underground drainage systems, catch basins or concealed sump pumps; swimming pools and related safety equipment, spas, hot tubs or saunas; whether deck, balcony and/or stair membranes are watertight; trees, landscaping, properties of soil, soil stability, erosion and erosion control; ponds, water features, irrigation or yard sprinkler systems; sport courts, playground, recreation or leisure equipment; areas below the exterior structures with less than 3 feet of vertical clearance; invisible fencing; sea walls, docks and boathouses; retractable awnings. Any comments made regarding these items are as a courtesy only.
Site profile: Level
Condition of driveway: Appeared serviceable
Driveway material: Brick
Condition of sidewalks and/or patios: Appeared serviceable
Sidewalk material: Paving stones
Condition of deck, patio and/or porch covers: Appeared serviceable
Deck, patio, porch cover material and type: Open
Condition of decks, porches and/or balconies: Appeared serviceable
Limitations: The inspector performs a visual inspection of accessible components or systems at the exterior. Items excluded from this inspection include below-grade foundation walls and footings; foundations, exterior surfaces or components obscured by vegetation, stored items or debris; wall structures obscured by coverings such as siding or trim. Some items such as siding, trim, soffits, vents and windows are often high off the ground, and may be viewed using binoculars from the ground or from a ladder. This may limit a full evaluation. Regarding foundations, some amount of cracking is normal in concrete slabs and foundation walls due to shrinkage and drying. Note that the inspector does not determine the adequacy of seismic reinforcement.
Wall inspection method: Viewed from ground
Condition of wall exterior covering: Appeared serviceable
Apparent wall structure: Concrete block
Wall covering: Stucco
Condition of foundation and footings: Appeared serviceable
Apparent foundation type: Concrete slab on grade
Foundation/stem wall material: Poured in place concrete, Concrete block
Footing material (under foundation stem wall): Poured in place concrete, Pre-cast concrete
3) Some sections of siding and/or trim were deteriorated and/or rotten. Recommend that a qualified person repair, replace or install siding or trim as necessary.
The tiki hut was located over the back part of the roof, causing rainwater to accumulate in the gutter and leading to rot in the flashing and soffits.
Significant amounts of debris have accumulated in one or more gutters or downspouts. Gutters can overflow and cause water to come in contact with the building exterior, or water can accumulate around the foundation. This is a conducive condition for wood-destroying organisms. Recommend cleaning gutters and downspouts now and as necessary in the future.
Cost estimate: $800.00
Photo 3-1 The tiki hut at the back of the house has caused damage to the roof as it overlaps, leading to the rotting of the flashing and soffit. Photo 3-2 The tiki hut at the back of the house has caused damage to the roof as it overlaps, leading to the rotting of the flashing and soffit.
Photo 3-3 The tiki hut at the back of the house has caused damage to the roof as it overlaps, leading to the rotting of the flashing and soffit. Photo 3-4 The tiki hut at the back of the house has caused damage to the roof as it overlaps, leading to the rotting of the flashing and soffit.
4) One exterior outlet was missing the safety face plate.
Cost estimate: $125.00 Service call
Photo 4-1 The safety plate was missing from an exterior electrical outlet. Photo 4-2 The safety plate was missing from an exterior electrical outlet.
5) The cleanout cap prevents sewage backflow and protects your home from harmful gases and foul smells. The cap's primary function is to create a closed plumbing system – containing the gases naturally accumulated in plumbing pipes.
Cost estimate: $10.00
Photo 5-1 The sewer cleaner cap was missing. Photo 5-2 The sewer cleaner cap was missing.
6) Trees were in contact with or were close to the building at one or more locations. Damage to the building can occur, especially during high winds, or may have already occurred (see other comments in this report). Recommend that a qualified tree service contractor or certified arborist remove trees as necessary to prevent damage to the building exterior.
One or more large trees were very close to the foundation. Tree roots can cause significant structural damage to foundations, or may have already caused damage (see other comments in this report). Recommend that a qualified tree service contractor or certified arborist remove trees as necessary to prevent damage to foundations.
Cost estimate: $1,200.00
Photo 6-1 The palm tree needs to be removed and the stump grinded to prevent damage to the roof and foundation. Photo 6-2 The palm tree needs to be removed and the stump grinded to prevent damage to the roof and foundation.
Photo 6-3 The palm tree needs to be removed and the stump grinded to prevent damage to the roof and foundation.
Limitations: The following items or areas are not included in this inspection: areas that could not be traversed or viewed clearly due to lack of access; solar roofing components. Any comments made regarding these items are made as a courtesy only. Note that the inspector does not provide an estimate of remaining life on the roof surface material, nor guarantee that leaks have not occurred in the roof surface, skylights or roof penetrations in the past. Regarding roof leaks, only active leaks, visible evidence of possible sources of leaks, and evidence of past leaks observed during the inspection are reported on as part of this inspection. The inspector does not guarantee or warrant that leaks will not occur in the future. Complete access to all roof and attic spaces during all seasons and during prolonged periods of all types of weather conditions (e.g. high wind and rain, melting snow) would be needed to do so. Occupants should monitor the condition of roofing materials in the future. For older roofs, recommend that a professional inspect the roof surface, flashings, appurtenances, etc. annually and maintain/repair as might be required. If needed, the roofer should enter attic space(s). Regarding the roof drainage system, unless the inspection was conducted during and after prolonged periods of heavy rain, the inspector was unable to determine if gutters, downspouts and extensions perform adequately or are leak-free.
Roof inspection method: Partially traversed, Viewed from eaves on ladder
Condition of roof surface material: Appeared serviceable
Roof surface material: Clay tile
Roof type: Gable
Condition of exposed flashings: Appeared serviceable
Condition of gutters, downspouts and extensions: Appeared serviceable
Limitations: The following items or areas are not included in this inspection: areas that could not be traversed or viewed clearly due to lack of access; areas and components obscured by insulation. Any comments made regarding these items are made as a courtesy only. The inspector does not determine the adequacy of the attic ventilation system. Complete access to all roof and attic spaces during all seasons and during prolonged periods of all types of weather conditions (e.g. high/low temperatures, high/low humidity, high wind and rain, melting snow) would be needed to do so. The inspector is not a licensed engineer and does not determine the adequacy of roof structure components such as trusses, rafters or ceiling beams, or their spacing or sizing.
Limitations: The inspector cannot reasonably determine the integrity of all elements of limited fire resistance at residential construction or verify firewall ratings at multi unit construction. Requirements for ventilation in garages vary between municipalities. The garage was converted into a room.
Limitations: The following items are not included in this inspection: generator systems, transfer switches, surge suppressors, inaccessible or concealed wiring; underground utilities and systems; low-voltage lighting or lighting on timers or sensors. Any comments made regarding these items are as a courtesy only. Note that the inspector does not determine the adequacy of grounding or bonding, if this system has an adequate capacity for the client's specific or anticipated needs, or if this system has any reserve capacity for additions or expansion. The inspector does not operate circuit breakers as part of the inspection, and does not install or change light bulbs. The inspector does not evaluate every wall switch or receptacle, but instead tests a representative number of them per various standards of practice. When furnishings, stored items or child-protective caps are present some receptacles are usually inaccessible and are not tested; these are excluded from this inspection. Receptacles that are not of standard 110 volt configuration, including 240-volt dryer receptacles, are not tested and are excluded. The functionality of, power source for and placement of smoke and carbon monoxide alarms is not determined as part of this inspection. Upon taking occupancy, proper operating and placement of smoke and carbon monoxide alarms should be verified and batteries should be changed. These devices have a limited lifespan and should be replaced every 10 years. The inspector attempts to locate and evaluate all main and sub-panels. However, panels are often concealed. If panels are found after the inspection, a qualified electrician should evaluate and repair if necessary. The inspector attempts to determine the overall electrical service size, but such estimates are not guaranteed because the overall capacity may be diminished by lesser-rated components in the system. Any repairs recommended should be made by a licensed electrician.
Electric service condition: Required repair, replacement and/or evaluation (see comments below)
Primary service type: Overhead
Number of service conductors: 2
Service voltage (volts): 120-240, 3 phase, 4 wire, 120
Estimated service amperage: 200
Primary service overload protection type: Circuit breakers, Fuses
Service entrance conductor material: Stranded aluminum
Main disconnect rating (amps): 200
System ground: Cold water supply pipes
Condition of main service panel: Appeared serviceable
Condition of sub-panel(s): Appeared serviceable
Location of main service panel #A: Building exterior
Location of main service panel #B: Laundry room
Location of main disconnect: Breaker at top of main service panel
Carbon monoxide alarms installed: Yes, but not tested
7) The service drop wires were less than 10 feet above the ground, a deck, or walkways. This is a shock hazard. A qualified electrician or utility company should repair per standard building practices.
The point of attachment of the overhead service conductors to a building or other structure shall provide the minimum clearances as specified in 230.9 and 230.24. In no case shall this point of attachment be less than 3.0 m (10 ft) above the finished grade.
Cost estimate: $125.00 service call
Photo 7-1 The service lines must be at least 10' above any hard surface. Photo 7-2 The service lines must be at least 10' above any hard surface.
Photo 7-3 The service lines must be at least 10' above any hard surface, and they were in direct contact with the rain gutter. Photo 7-4 The service lines must be at least 10' above any hard surface, and they were in direct contact with the rain gutter.
Photo 7-5 The service lines must be at least 10' above any hard surface, and they were in direct contact with the rain gutter. Photo 7-6 The service lines must be at least 10' above any hard surface, and they were in direct contact with the rain gutter.
8) The condition of these panel(s) is unknown and they are excluded from this inspection. Repairs may be needed. Recommend that a qualified person correct conditions, or that a qualified contractor make repairs if necessary so panels can be opened, and that a qualified person fully evaluate panel(s).
***Recommend getting full knowledge and how to engage and disengage the stand-alone generator and the electrical components.
Cost estimate: $125.00 Service call
Photo 8-1 Before residents move in, it is important to test the generator and electrical system. Photo 8-2 Before residents move in, it is important to test the generator and electrical system.
Photo 8-3 Before residents move in, it is important to test the generator and electrical system. Photo 8-4 Before residents move in, it is important to test the generator and electrical system.
Photo 8-5 Before residents move in, it is important to test the generator and electrical system. Photo 8-6 Before residents move in, it is important to test the generator and electrical system.
9) Neutral wires were doubled or bundled together under the same lug on the neutral bus bar in panel(s) #C. This is a potential safety hazard in the event that one of the circuits needs to be isolated during servicing. For one neutral to be disconnected, other neutrals from energized circuits sharing the same lug will be loosened. Power surges may result on the energized circuits and result in damage or fire. Also, multiple wires under the same lug may not be secure, resulting in loose wires, arcing, sparks and fire. Recommend that a qualified electrician repair per standard building practices. For more information, visit: http://www.reporthost.com/?DTNB Cost estimate: $125.00 Service call
Photo 9-1 A double tap was noted on the neutral bus bar.
10) One or more smoke alarms were missing, damaged, or missing components. Smoke alarms should be replaced as necessary. For more information, visit: http://www.reporthost.com/?SMKALRM Cost estimate: $50.00
Photo 10-1 Recommend replacing all missing smoke detectors.
11) Using electrical outlet without a cover plate or faceplate is not safe. Cover plates and faceplates are designed to protect the electrical wiring and components inside the outlet, as well as to prevent accidental contact with live wires.
Cost estimate: $10.00
Photo 11-1 The electrical face plate was missing from under the sink. Photo 11-2 The electrical face plate was missing from under the sink.
12) Branch circuit wiring installed in buildings built prior to the mid 1980s is typically rated for a maximum temperature of only 60 degrees Celsius. This includes non-metallic sheathed (Romex) wiring, and both BX and AC metal-clad flexible wiring. Knob and tube wiring, typically installed in homes built prior to 1950, may be rated for even lower maximum temperatures. Newer electric fixtures including lighting and fans typically require wiring rated for 90 degrees Celsius. Connecting newer fixtures to older, 60-degree-rated wiring is a potential fire hazard. Repairs for such conditions may involve replacing the last few feet of wiring to newer fixtures with new 90-degree-rated wire, and installing a junction box to join the old and new wiring.
It is beyond the scope of this inspection to determine if such incompatible components are installed, or to determine the extent to which they're installed. Based on the age of this building, the client should be aware of this safety hazard, both for existing fixtures and when planning to upgrade with newer fixtures. Consult with a qualified electrician for repairs as necessary.
13) Since electrical energy can be a significant hazard, using blunt-tipped screws is an extremely important and easy way to prevent injury or death when working around electrical panels. If your electrical panel contains sharp-tipped screws, do not screw this back into the panel as they could come in contact with wiring.
Keeping unused breakers in place may limit the capacity for future expansion or modifications to the electrical system. It's generally best to remove unused breakers and properly cap off the corresponding wires for safety and clarity.
Cost estimate: $25.00
Photo 13-1 The electrical panel was missing screws, and the wrong screws were being used. Photo 13-2 The electrical panel was missing screws, and the wrong screws were being used.
Photo 13-3 The electrical panel was missing screws, and the wrong screws were being used. Photo 13-4 The electrical panel was missing screws, and the wrong screws were being used.
Photo 13-5 Recommend removing any unused breakers in the panel. Photo 13-6 Recommend removing any unused breakers in the panel.
Photo 13-7 Loose wires were noted in the electrical panel. Recommend either connecting them to the proper breaker, or capping them.
Limitations: The following items are not included in this inspection: private/shared wells and related equipment; private sewage disposal systems; hot tubs or spas; main, side and lateral sewer lines; gray water systems; pressure boosting systems; trap primers; incinerating or composting toilets; fire suppression systems; water softeners, conditioners or filtering systems; plumbing components concealed within the foundation or building structure, or in inaccessible areas such as below tubs; underground utilities and systems; overflow drains for tubs and sinks; backflow prevention devices. Any comments made regarding these items are as a courtesy only. Note that the inspector does not operate water supply or shut-off valves due to the possibility of valves leaking or breaking when operated. The inspector does not test for lead in the water supply, the water pipes or solder, does not determine if plumbing and fuel lines are adequately sized, and does not determine the existence or condition of underground or above-ground fuel tanks.
Condition of service and main line: Appeared serviceable
Water service: Public
Location of main water shut-off: Building exterior
Condition of supply lines: Appeared serviceable
Supply pipe material: Copper
Condition of drain pipes: Appeared serviceable
Drain pipe material: Plastic
Condition of waste lines: Appeared serviceable
Waste pipe material: Plastic
Vent pipe condition: Appeared serviceable
Vent pipe material: Galvanized steel
Sump pump installed: No
Sewage ejector pump installed: No
Type of irrigation system supply source: Public
14) Rusted or corroded gas lines should always be addressed immediately. Because rust or corrosion on your gas lines will quickly spread, replacement is the best solution. This is because the metal has already begun to weaken. Recommend a qualified company replace the valve. **NO GAS LEAK WAS DETECTED.
Cost estimate: $125.00 Service call
Photo 14-1 Corrosion was observed on the gas pipe, but no leaks were detected. Photo 14-2 Corrosion was observed on the gas pipe, but no leaks were detected.
15) How important is a water softener? The mineral ions in hard water prevent it from dissolving soaps properly. Homes with a water softener enjoy a better lather and a better bathing experience. Softened water also eliminates the harmful effects hard water has on your body due to the destruction of natural oils in your skin and hair. It also prevents the build-up of minerals (scale) on the inside of pipes, fixtures, and water heaters. Lengthens the life of some appliances. Reduces or prevents mineral spots on glassware. Prevents or reduces soap films and detergent curds in sinks, bathtubs, and washing machines.
Cost estimate: $125.00 Service call
Photo 15-1 The water softener system needs to be flushed and the holding tank requires cleaning. Photo 15-2 The water softener system needs to be flushed and the holding tank requires cleaning.
Limitations: Evaluation of and determining the adequacy or completeness of the following items are not included in this inspection: water recirculation pumps; solar water heating systems; Energy Smart or energy saver controls; catch pan drains. Any comments made regarding these items are as a courtesy only. Note that the inspector does not provide an estimate of remaining life on water heaters, does not determine if water heaters are appropriately sized, or perform any evaluations that require a pilot light to be lit or a shut-off valve to be operated.
Limitations: The following items are not included in this inspection: humidifiers, dehumidifiers, electronic air filters; solar, coal or wood-fired heat systems; thermostat or temperature control accuracy and timed functions; heating components concealed within the building structure or in inaccessible areas; underground utilities and systems; safety devices and controls (due to automatic operation). Any comments made regarding these items are as a courtesy only. Note that the inspector does not provide an estimate of remaining life on heating or cooling system components, does not determine if heating or cooling systems are appropriately sized, does not test coolant pressure, or perform any evaluations that require a pilot light to be lit, a shut-off valve to be operated, a circuit breaker to be turned "on" or a serviceman's or oil emergency switch to be operated. It is beyond the scope of this inspection to determine if furnace heat exchangers are intact and free of leaks. Condensation pans and drain lines may clog or leak at any time and should be monitored while in operation in the future. Where buildings contain furnishings or stored items, the inspector may not be able to verify that a heat source is present in all "liveable" rooms (e.g. bedrooms, kitchens and living/dining rooms).
General heating system type(s): Forced air, Heat pump
General heating distribution type(s): Ducts and registers
Last service date of primary heat source: UNK
Condition of forced air heating/(cooling) system: Appeared serviceable
Forced air heating system fuel type: Electric
Location of forced air furnace: Attic
Forced air system capacity in BTUs or kilowatts: 48,000BTUS
Location for forced air filter(s): Behind return air grill(s)
Condition of forced air ducts and registers: Appeared serviceable
Condition of controls: Appeared serviceable
16) The last service date of the forced air heating/cooling system appeared to be more than 1 year ago, or the inspector was unable to determine the last service date. Ask the property owner when it was last serviced. If unable to determine the last service date, or if this system was serviced more than 1 year ago, recommend that a qualified HVAC contractor service this system and make repairs if necessary. Because this system has a compressor and refrigerant system, this servicing should be performed annually in the future. Any needed repairs noted in this report should be brought to the attention of the contractor when it's serviced.
Cost estimate: $850.00
Photo 16-1 The air conditioning system requires servicing and straightening of the fins to improve its performance. Photo 16-2 The air conditioning system requires servicing and straightening of the fins to improve its performance.
Photo 16-3 The air conditioning system requires servicing and straightening of the fins to improve its performance.
Limitations: The following items are not included in this inspection: coal stoves, gas logs, chimney flues (except where visible). Any comments made regarding these items are as a courtesy only. Note that the inspector does not determine the adequacy of drafting or sizing in fireplace and stove flues, and also does not determine if prefabricated or zero-clearance fireplaces are installed in accordance with the manufacturer's specifications. The inspector does not perform any evaluations that require a pilot light to be lit, and does not light fires. The inspector provides a basic visual examination of a chimney and any associated wood burning device. The National Fire Protection Association has stated that an in-depth Level 2 chimney inspection should be part of every sale or transfer of property with a wood-burning device. Such an inspection may reveal defects that are not apparent to the home inspector who is a generalist.
Condition of wood-burning fireplaces, stoves: Required repair, replacement and/or evaluation (see comments below)
Wood-burning fireplace type: Masonry with metal liner
Wood-burning stove type: Attached
17) The metal fireplace liner was rusty. Significant rust can cause holes in metal. Fireplaces with metal liners typically circulate indoor air behind the firebox and act as a "heatilator" where warmed air is blown or drawn back into the living area. When holes form in liners, smoke and combustion gases can enter the heatilator chamber and living spaces. This is a potential safety hazard. Recommend that a qualified specialist evaluate and repair if necessary.
One or more solid fuel-burning fireplaces or stoves were found at the property. When such devices are used, they should be professionally inspected and cleaned annually to prevent creosote build-up and to determine if repairs are needed. The National Fire Protection Association states that a "Level 2" chimney inspection should be performed with every sale or transfer of property with a wood-burning device. Recommend consulting with the property owner about recent and past servicing and repairs to all wood-burning devices and chimneys or flues at this property. Recommend that a qualified specialist evaluate all solid fuel-burning devices and chimneys, and clean and repair as necessary. Note that if a wood stove insert is installed, it may need to be removed for such an evaluation. For more information, search for "chimney inspection" at: http://www.reporthost.com/?CSIA
Holes or cracks were found in the metal fireplace liner. Fireplaces with metal liners typically circulate indoor air behind the firebox and act as a "heatilator" where warmed air is blown or drawn back into the living area. When holes or cracks form in liners, smoke and combustion gases can enter the heatilator chamber and living spaces. This is a potential safety hazard. Recommend that a qualified specialist evaluate and repair if necessary.
Cost estimate: $125.00 Service call
Photo 17-1 It is crucial to repair and service the fireplace before burning any wood to ensure safety and prevent any potential hazards. Photo 17-2 It is crucial to repair and service the fireplace before burning any wood to ensure safety and prevent any potential hazards. **Large amounts of rust were noted in the chimney.
Photo 17-3 It is crucial to repair and service the fireplace before burning any wood to ensure safety and prevent any potential hazards. **Large amounts of rust were noted in the chimney. Photo 17-4 It is crucial to repair and service the fireplace before burning any wood to ensure safety and prevent any potential hazards. **Large amounts of rust were noted in the chimney.
Limitations: The following items are not included in this inspection: household appliances such as stoves, ovens, cook tops, ranges, warming ovens, griddles, broilers, dishwashers, trash compactors, refrigerators, freezers, ice makers, hot water dispensers and water filters; appliance timers, clocks, cook functions, self and/or continuous cleaning operations, thermostat or temperature control accuracy, and lights. Any comments made regarding these items are as a courtesy only. Note that the inspector does not provide an estimate of the remaining life of appliances, and does not determine the adequacy of operation of appliances. The inspector does not note appliance manufacturers, models or serial numbers and does not determine if appliances are subject to recalls. Areas and components behind and obscured by appliances are inaccessible and excluded from this inspection.
Condition of counters: Appeared serviceable
Condition of cabinets: Appeared serviceable
Condition of sinks and related plumbing: Appeared serviceable
Condition of under-sink food disposal: Appeared serviceable
Condition of ranges, cooktops and/or ovens: Appeared serviceable
Range, cooktop, oven type: Propane
Type of ventilation: Hood or built into microwave over range or cooktop
Condition of refrigerator: Appeared serviceable
Condition of built-in microwave oven: Appeared serviceable
18) Countertops and/or backsplashes were damaged or deteriorated. Recommend repairing or replacing as necessary.
Cost estimate: $125.00 Service call
Photo 18-1 A tile was missing from the back splash in the kitchen. Photo 18-2 A tile was missing from the back splash in the kitchen.
19) Changes to the 2020 NEC required at least one receptacle outlet to be installed in all islands and peninsulas, and potentially more depending on the overall square footage of the countertop or work surface for the island or peninsula.
Cost estimate: $125.00 Service call
Photo 19-1 The kitchen island was on casters and did not have any electrical outlets.
Limitations: The following items are not included in this inspection: overflow drains for tubs and sinks; heated towel racks, saunas, steam generators, clothes washers, clothes dryers. Any comments made regarding these items are as a courtesy only. Note that the inspector does not determine the adequacy of washing machine drain lines, washing machine catch pan drain lines, or clothes dryer exhaust ducts. The inspector does not operate water supply or shut-off valves for sinks, toilets, bidets, clothes washers, etc. due to the possibility of valves leaking or breaking when operated. The inspector does not determine if shower pans or tub and shower enclosures are water tight, or determine the completeness or operability of any gas piping to laundry appliances.
Location #A: Master bath
Location #B: Full bath
Condition of counters: Appeared serviceable
Condition of cabinets: Appeared serviceable
Condition of flooring: Appeared serviceable
Condition of sinks and related plumbing: Appeared serviceable
Condition of toilets: Appeared serviceable
Condition of bathtubs and related plumbing: Appeared serviceable
Condition of shower(s) and related plumbing: Appeared serviceable
Condition of ventilation systems: Appeared serviceable
Bathroom and laundry ventilation type: Windows, Central exhaust fan
Gas supply for laundry equipment present: Yes
240 volt receptacle for laundry equipment present: No
20) One or more missing handles were found at water shut-off valves for the sink at location(s) #B and/or missing. A qualified plumber should repair as necessary.
Cost estimate: $125.00 Service call
Photo 20-1 The shutoff valve handles were missing. Photo 20-2 The shutoff valve handles were missing.
21) Duct joints shall be installed so that the male end of the duct points in the direction of the airflow. Joints should be secured with metal tape (not duct tape). Do not use rivets or screws in the joints or anywhere else in the duct as these will encourage lint collection.
Cost estimate: $0.00
Photo 21-1 Please make sure to properly attach the dryer vent to prevent any potential leaks.
22) One or more bathtub faucet handles at location(s) #A were loose. Recommend that a qualified person repair or replace handles as necessary.
The shower head was not engaging.
Cost estimate: $125.00 Service call
Photo 22-1 The diverter valve located in the main bathroom shower is broken and requires repair. Photo 22-2 The diverter valve located in the main bathroom shower is broken and requires repair.
Photo 22-3 The drain plug needs to be installed in the master bathroom tub. Photo 22-4 The drain plug needs to be installed in the master bathroom tub.
23) The clothes washer drain standpipe was too short. Standard building practices require that the stand pipe be:
A minimum of 2 inches in diameter
At least 33 inches tall for a top-loading clothes washer
At least 24 inches tall for a front-loading clothes washer
Recommend that a qualified person repair as necessary per standard building practices.
Cost estimate: $125.00 Service call
Photo 23-1 The washing machine was not inspected and was disconnected. It is recommended to operate the washer first to ensure there are no active leaks. Photo 23-2 The washing machine was not inspected and was disconnected. It is recommended to operate the washer first to ensure there are no active leaks, due to the drain pipe being so low.
24) The shower head at location(s) #B was dripping when the shower was being operated, and the faucet was loose. Recommend that a qualified person repair as necessary.
Cost estimate: $125.00 Service call
Photo 24-1 The shower faucet was loose and needs to be secured to prevent water intrusion. Photo 24-2 The shower faucet was loose and needs to be secured to prevent water intrusion.
Photo 24-3 The shower head has a continuous leak, and needs to be repaired.
Limitations: The following items are not included in this inspection: security, intercom and sound systems; communications wiring; central vacuum systems; elevators and stair lifts; cosmetic deficiencies such as nail-pops, scuff marks, dents, dings, blemishes or issues due to normal wear and tear in wall, floor and ceiling surfaces and coverings, or in equipment; deficiencies relating to interior decorating; low voltage and gas lighting systems. Any comments made regarding these items are as a courtesy only. Note that the inspector does not evaluate any areas or items which require moving stored items, furnishings, debris, equipment, floor coverings, insulation or similar materials. The inspector does not test for asbestos, lead, radon, mold, hazardous waste, urea formaldehyde urethane, or any other toxic substance. Some items such as window, drawer, cabinet door or closet door operability are tested on a sampled basis. The client should be aware that paint may obscure wall and ceiling defects, floor coverings may obscure floor defects, and furnishings may obscure wall, floor and floor covering defects. If furnishings were present during the inspection, recommend a full evaluation of walls, floors and ceilings that were previously obscured when possible. Carpeting and flooring, when installed over concrete slabs, may conceal moisture. If dampness wicks through a slab and is hidden by floor coverings that moisture can result in unhygienic conditions, odors or problems that will only be discovered when/if the flooring is removed. Determining the cause and/or source of odors is not within the scope of this inspection.
Condition of exterior entry doors: Appeared serviceable
Exterior door material: Fiberglass or vinyl, Glass panel
Condition of interior doors: Appeared serviceable
Condition of windows and skylights: Appeared serviceable
Type(s) of windows: Metal, Multi-pane
Condition of walls and ceilings: Appeared serviceable
Wall type or covering: Drywall
Ceiling type or covering: Plaster
Condition of flooring: Appeared serviceable
Flooring type or covering: Tile
25) Screens were missing from some windows. These windows may not provide ventilation during months when insects are active.
Several blinds were broken from the rear door.
Cost estimate: $125.00 Service call
Photo 25-1 Several windows screens were missing from windows. Photo 25-2 Several blinds were missing from the Bahama shutters
Photo 25-3 Several blinds were missing from the Bahama shutters Photo 25-4 Several blinds were missing from the Bahama shutters
26) One or more walls were damaged and/or had substandard repairs. Recommend that a qualified person repair as necessary.
Cost estimate: $125.00 Service call
Photo 26-1 Old water damage was noted on the living room wall. 20% moisture was detected. Photo 26-2 Old water damage was noted on the living room wall. 20% moisture was detected.
27) No switches or controls were noted to control the ceiling fans. Recommend asking the home owner if they are remote controlled.
Cost estimate: $0.00
Photo 27-1 There was no switch available to operate the ceiling fans in the bedroom. *Master bedroom Photo 27-2 There was no switch available to operate the ceiling fans in the bedroom. *Second bedroom
Photo 27-3 There was no switch available to operate the ceiling fans in the bedroom. *Living room.
28) A well-lit closet is easy to navigate and organize, and feels more accessible. Closet lighting can be more than just functional – a well-lit closet looks better, too. On the other hand, a dark closet is difficult to use, and difficult to declutter, and you can easily lose items within it.
Cost estimate: $125.00 Service call
Photo 28-1 The lights inside the closet of the second bedroom are not functioning. Photo 28-2 The lights inside the closet of the second bedroom are not functioning.
Limitations: This report only includes findings from accessible and visible areas on the day of the inspection. In addition to the inaccessible areas documented in this report, examples of other inaccessible areas include: sub areas less than 18 inches in height; attic areas less than 5 feet in height, areas blocked by ducts, pipes or insulation; areas where locks or permanently attached covers prevent access; areas where insulation would be damaged if traversed; areas obscured by vegetation. All inaccessible areas are subject to infestation or damage from wood-destroying organisms. The inspector does not move furnishings, stored items, debris, floor or wall coverings, insulation, or other materials as part of the inspection, nor perform destructive testing. Wood-destroying organisms may infest, re-infest or become active at any time. No warranty is provided as part of this inspection.
Visible evidence of active wood-destroying insects: No
Visible evidence of active wood decay fungi: No
Visible evidence of past wood-destroying insects: Yes
Visible evidence of past wood decay fungi: No
Visible evidence of damage by wood-destroying insects: No
Visible evidence of damage by wood decay fungi: No
Visible evidence of conditions conducive to wood-destroying organisms: No
Evidence of prior treatment of wood-destroying insects: Label in the attic
29) Evidence of past infestation of drywood termites was found at location(s) #Attic in the form of fecal pellets with no visible wood damage. Recommend the following:
Correct any conducive conditions for wood-destroying organisms mentioned in this report.
Consult with the property owner about any history of infestation.
Have a state-licensed pest control operator evaluate further and treat as necessary.
Cost estimate: $125.00 Service call
Photo 29-1 A label was found in the attic indicating that a termite inspection had been conducted recently. Photo 29-2 A large amount of termite pellets were found in the attic. No active or dead termites were seen.
Photo 29-3 A large amount of termite pellets were found in the attic. No active or dead termites were seen.
Customer named above hereby requests a Residential Property Inspection of the primary residence and all appurtenant structures at the above address, to be conducted by the above inspection company (herein referred to as the Inspector), for the Customer’s sole use and benefit. Customer agrees to carefully read the entire Agreement and Inspection Report as they receive them and promptly call the Inspector with any questions Customer may have. To the extent any information discussed in any said oral communications are important to Customer, such discussions shall be incorporated into this Agreement in writing and signed by each of the parties or such discussions shall be superseded by the Inspection Report. Customer warrants that all necessary approvals have been secured for Inspector’s safe entrance onto the subject property.
SCOPE OF SERVICES PROVIDED The Residential Property Inspection the Inspector will perform for Customer (it being understood and agreed that the person or persons signing this Agreement as “Customer(s)” do so on behalf of all those on whose behalf the Inspection and Report is being obtained) is a non-invasive physical and visual observation of the visible portions of the structures, components, features, systems or items on the property identified and described below. Based on that observation, the Inspector will provide Customer with an Inspection Report. This Agreement and all printed and written statements in the Inspection Report define the limited scope of the Residential Property Inspection and the Inspection Report. The Inspection Report will inform the Customer of significant visible defects or conditions that were observed at the time of the Residential Property Inspection. The Inspector will not be obligated to comment upon or disclose conditions that are aesthetic in nature. This Residential Property Inspection is limited to a visual examination of the structures, components, features, systems or items that are normally exposed and readily accessible during the time of the Residential Property Inspection. The Residential Property Inspection does not contemplate or involve the dismantling, removal or moving of any object or portion of the premises. Generally, this means that the following major structures, components, features, systems or items will be observed and evaluated to the extent possible under the circumstances: the building’s foundation; sub floor framing; site drainage as it affects the structure(s); electrical system and equipment; plumbing system and fixtures; heating, ventilation and air conditioning system, controls and ducting; water heating; exterior walls, eaves, windows, doors, trim, and appurtenances; roof and gutters; attic; venting; fireplaces and chimneys; interior walls, ceilings, floors and their coverings, stairs, doors, windows. Additional property features that may be included in the scope of the Residential Property Inspection, if they are within 12 feet of the primary structure(s), include decks, fencing and paving. Any minor defects that may be mentioned in the Inspection Report are included as a courtesy only and in no way expand or redefine the scope. The inspection will be performed in accordance with the Standards of Practice enclosed with this report or otherwise provided to Customer. Inherent, latent and concealed defects and deficiencies are excluded from the Inspection Report. Inspector shall have no liability for defects or conditions in structures, components, features, systems or items which are concealed from view or not readily accessible to the Inspector at the time of the Residential Property Inspection, for whatever reason. Weather conditions at the time of the Residential Property Inspection may limit the inspection of some structures, components, features, systems or items, or the ability of the Inspector to detect defects, damage or potential for problems. The Residential Property Inspection and Inspection Report thereon is not a warranty, guarantee, or insurance policy. The Residential Property Inspection and Inspection Report are not intended and should not be used as a substitute for or relied upon as real estate transfer disclosures, which may be required by law. Home warranty policies, which include coverage for appliances, electrical, plumbing, heating and air conditioning systems are available, if desired. For information on such insurance, consult a licensed real estate professional. Your use or reference to the Inspection Report may help you identify some deficiencies in the property that is the subject of this Residential Property Inspection, but it cannot, and is not intended to, eliminate all risk. The Residential Property Inspection and the Inspection Report are limited to the real property and do not include any personal property unless otherwise indicated in this Inspection Report. In the case of those items that are present in multiples in a typical residence, a representative sample of such items (e.g., cabinets, windows, the presence of safety glass in doors and windows, the operation and safety of electrical outlets and switches) is selected and checked. No representation is made as to the remaining useful life of any structure, component, feature, system, equipment or item that is covered by this Residential Property Inspection. Maintenance conditions may be discussed, but they are not a part of this Residential Property Inspection. The Residential Property Inspection covers only those structures, components, features, systems or items expressly listed in the Inspection Report. Unless specifically agreed in advance between the Inspector and the Customer, the areas, structures, components, features, systems, equipment, items, risks, hazards or conditions excluded from the Residential Property Inspection and Inspection Report include, but are not limited to the following: 1. Evaluating or reporting on compliance or non-compliance with: international, state or local building, use, or zoning codes; ordinances; regulations; covenants; charters or other restrictions; requirements of the federal Americans with Disabilities Act (A.D.A.) and similar state or local laws or regulations. Researching, evaluating or reporting on permits and/or their verification. Researching, evaluating or reporting on compliance or non-compliance with set-backs and easements; rights of way; property boundaries; conditions of title; previous ownership(s), events, use or occupancies relative to the subject property. 2. Seeking, obtaining, evaluating or reporting on information that may be available from any third parties, including but not limited to: sellers, occupants, contractors, consultants, managers, government agencies, attorneys, agents, manufacturers, or homeowner associations. Researching, evaluating or reporting on compliance with manufacturers’ specifications or installation guidelines. 3. Inspecting, testing, evaluating or reporting on common areas or systems, structures or components thereof, including, but not limited to, those systems, structures or components maintained by a homeowners association or similar common management. 4. Inspecting, evaluating or reporting on conditions related to animals, rodents, insects, wood-destroying insects or organisms, mold and mildew, or damage(s) caused thereby. 5. Researching, testing, evaluating or reporting on information and/or conditions pertaining to the history or likelihood of wildfires or floods. 6. Performing or reporting any form of engineering analysis such as: structural, geological, seismic, hydrological stability, or soil condition and/or erosion evaluations; land surveying; or architectural evaluations. Performing or reporting any technically exhaustive or technically specialized inspections, evaluations, or tests of any type. Performing or reporting evaluations regarding the fire-resistive properties of any system, structure or component of the building. Testing, analysis, evaluation or reporting on unique, custom and/or technically complex systems or devices, such as: heat exchangers; solar and radiant heat performance of buildings; insulative performance; remote control systems; light, motion or pressure sensing devices used in conjunction with lighting and/or security systems; security, emergency or fire safety systems (other than smoke alarms); security bars and/or safety/escape equipment; secured, safety or panic rooms and their systems; seismic safety valves or controls; solar heating and/or solar electric systems; air filters and/or air quality systems; radio-, telephone- or computer-controlled devices or systems; automatic timer controls; elevators, lifts and dumbwaiters; satellite dishes; automatic gates, their sensors and controls; clocks, thermostats, etc. 7. Researching, inspecting, testing, evaluating or reporting on information and/or conditions pertaining to environmental and health hazards, concerns or conditions, including, but not limited to: toxic, reactive, combustible and corrosive contaminants, such as asbestos, lead, radon, electromagnetic fields, urea formaldehyde, PCB’s, or chlordane; soil quality or contamination; water quality or contamination; underground storage tanks; proximity or other exposure to toxic waste sites; mold or mildew; organic or inorganic allergens; and chemical sensitizers. 8. Performing or reporting any electrical load calculations. Testing, evaluation or reporting on low voltage electrical systems, such as TV antennae, TV signal cables, telephones, telephone cables and lines, intercoms, security systems and their wiring, speaker wires, automated equipment, landscape lighting, etc. Testing, evaluation or reporting on gas shutoff valves. Inspecting for, detection of, or evaluation or reporting of any active or potential gas leaks. 9. Researching, inspecting, testing, evaluating or reporting on private water or private sewage systems or related equipment, such as wells, septic systems, sewage ejector pumps, water softeners, water purification systems, etc. Researching, inspecting, testing, evaluating or reporting on fire sprinklers. Inspecting, testing, evaluating or reporting on landscaping sprinklers and irrigation systems, except as otherwise noted. Inspecting, testing, evaluating or reporting on swimming pools, spas or hot tubs; fountains, ponds or water features; saunas or steam baths; or similar fixtures and equipment. 10. Researching, inspecting, evaluating or reporting on building or property line measurements, property value appraisal, and costs for any corrective work that might result from information provided in the Inspection Report or otherwise. Inspecting, evaluating or reporting on detached ancillary buildings (except for parking structures if included or as otherwise noted in the Inspection Report). 11. Inspecting, testing, evaluating or reporting on awnings, sun shades/screens, window films or coatings, sealed multi-pane window systems, storm windows, storm doors, shutters, and other such accessories. 12. Evaluating or reporting on the adequacy, efficiency, durability or quality of any system, structure or component. Researching, identifying or reporting on any product recalls, reported defects, or similar notices. Researching, inspecting, identifying or reporting on inherent or latent defects or known impairments to the useful life expectancy of systems, structures or components. 13. Inspecting, testing, evaluating or reporting on appliances and systems, structures, or components that are not permanently installed and are not typically sold as part of a residential property. Inspecting, testing, evaluating or reporting on window-mount or through-the-wall air conditioners or gas-powered air conditioners. Inspecting, testing, evaluating or reporting on gas and electrical appliances such as fire pits, barbecues, outside heaters and lamps. 14. Researching, evaluating or reporting on the desirability, advisability of purchase, the fair market value, or the current or potential marketability of the subject property. Examining, testing, evaluating or reporting on noise, vibration, odor, light or other nuisance characteristics of any system, structure, or component on the subject property, or of any adjoining or nearby property, neighborhood or region. Researching, evaluating or reporting on regional weather patterns or animal migratory habits, and/or their potential effects on the subject property and its desirability, marketability or enjoyment. Researching, identifying, testing, evaluating and/or reporting on any condition located off the subject property that may adversely affect the desirability, marketability or enjoyment of the property, including, but not limited to: railroad tracks and yards; roadways and highways; agricultural, commercial and industrial establishments; and airplane routes or airports. 15. Inspecting, evaluating or reporting on cosmetic finishes and/or their condition, trees, lawns, landscaping and plants. 16. Items specifically noted as excluded in the Inspection Report or items not specifically identified as included in the Inspection Report. Inspecting and reporting on some of the excluded items listed above may be available from Inspector for an additional fee.
INSPECTOR QUALIFICATIONS Customer understands that the Inspector is a generalist, with only a general and non-specialized knowledge of residential property construction and related fields. The Inspector is not and does not represent him/herself as an expert in any specific field unless otherwise indicated in writing. The Residential Property Inspection and the Inspection Report provides the Customer with an independent evaluation of the subject property, based upon the experience of the individual Inspector. The Inspection Report identifies general, visible conditions that are believed to currently affect the subject property. The Inspector may recommend specialized experts for further evaluations or repairs; the decision to contact and employ any such experts is at the Customer’s sole discretion and expense. Customer’s failure to consult specialized experts as recommended by the Inspector or as would otherwise be prudent under the circumstances shall absolve the Inspector of all liability.
STATUTE OF LIMITATIONS THE PARTIES AGREE THAT NO LEGAL ACTION OR PROCEEDING OF ANY KIND, INCLUDING THOSE SOUNDING IN TORT OR CONTRACTS MAY BE COMMENCED AGAINST THE INSPECTOR OR THE INSPECTION COMPANY, OR ITS OFFICERS, AGENTS OR EMPLOYEES MORE THAN ONE YEAR AFTER THE DATE OF THE SUBJECT RESIDENTIAL PROPERTY INSPECTION. TIME IS EXPRESSLY OF THE ESSENCE HEREIN. CUSTOMER(S) UNDERSTAND(S) THAT THIS TIME PERIOD MAY BE SHORTER THAN OTHERWISE PROVIDED BY LAW. BY INITIALING IMMEDIATELY BELOW, I CERTIFY THAT I HAVE READ, UNDERSTOOD, AND AGREE TO THIS PROVISION. WAIVER OF CONSEQUENTIAL AND PUNITIVE DAMAGES; LIQUIDATED DAMAGES IT IS UNDERSTOOD AND AGREED TO BY THE PARTIES HERETO THAT THE INSPECTOR IS NOT AN INSURER, THAT THE PAYMENT FOR THE RESIDENTIAL PROPERTY INSPECTION AND INSPECTION REPORT IS BASED SOLELY ON THE VALUE OF THE SERVICE PROVIDED BY THE INSPECTOR IN THE PERFORMANCE OF THE LIMITED VISUAL RESIDENTIAL PROPERTY INSPECTION AND PRODUCTION OF THE INSPECTION REPORT AS DESCRIBED HEREIN, THAT IT IS IMPRACTICABLE AND EXTREMELY DIFFICULT TO FIX ACTUAL DAMAGES, IF ANY, WHICH MAY RESULT FROM A FAILURE TO PERFORM SUCH SERVICES, AND IN THE CASE OF FAILURE TO PERFORM SUCH SERVICES AND A RESULTING LOSS, INSPECTOR’S LIABILITY HEREUNDER SHALL BE LIMITED AND FIXED IN AMOUNT EQUAL TO THE INSPECTION FEE MULTIPLIED BY FOUR AS LIQUIDATED DAMAGES, AND NOT AS A PENALTY, AND THIS LIABILITY SHALL BE EXCLUSIVE. FURTHERMORE, EXCEPT AS OTHERWISE HEREIN EXPRESSLY PROVIDED, AS MATERIAL CONSIDERATION HEREUNDER, THE PARTIES EACH WAIVE AGAINST THE OTHER, ALL DAMAGES OF A CONSEQUENTIAL NATURE AS WELL AS ALL THOSE WHICH MAY BE CHARACTERIZED OR DEEMED PUNITIVE OR EXEMPLARY. BY INITIALING IMMEDIATELY BELOW, I CERTIFY THAT I HAVE READ, UNDERSTOOD, AND AGREE TO THIS PROVISION.
ACCEPTANCE The Inspection Report shall be considered the final and exclusive findings of the Inspector regarding the Residential Property Inspection. Customer shall not rely on any oral statements made by the Inspector prior to or incident to issuance of the written Inspection Report. All the provisions, limitations, exceptions and exclusions of this agreement shall apply to any optional services that Customer requests and Inspector provides. This Agreement shall be binding upon and inure to the benefit of the parties hereto, their heirs, successors, and assigns however this Agreement may not be enforced by or on behalf of any alleged third party beneficiary. This Agreement and the printed terms, descriptions, conditions, limitations, exceptions and exclusions contained in the printed Inspection Report constitute the entire agreement between the parties hereto pertaining to the subject matter hereof, and may be modified only by a mutual written agreement signed by the Customer and the Inspector. No oral agreements, understandings, or representations shall in any way modify this Agreement.
SWIMMING POOL Inspector will perform a basic "visual inspection" of the pool's water condition (clarity), pool pump, pool filter, floor, walls, steps, ladders, railings, pool's timer control box, drain covers, visible drains for damage or blockage, coping and pool light. Inspector does NOT inspect for leaks, pool heaters (gas, electric or solar), gas tanks for gas heaters, electronic or computerized pool timers or controls, pool covers, diving boards, slides, Waterfalls, Spas or Jacuzzi’s.