View as PDF

View summary

Logo

On Point Home Inspections of FL LLC

http://www.ophif.com
ophioffl@yahoo.com
(305) 788-8910
Inspector: William Reguera
FL HI9889
Title picture

Property Inspection Report
Unofficial version!

Client(s): Vivian N. Matos & Danielle F. Serret
Property address: 800 North 29th Avenue
Hollywood, FL. 33020
Inspection date: Friday, January 5, 2024

This report published on Friday, January 5, 2024 4:05:11 PM EST

This report is the exclusive property of this inspection company and the client(s) listed in the report title. Use of this report by any unauthorized persons is prohibited.

How to Read this Report
This report is organized by the property's functional areas. Within each functional area, descriptive information is listed first and is shown in bold type. Items of concern follow descriptive information. Concerns are shown and sorted according to these types:
Concern typeSafetyPoses a safety hazard
Concern typeMajor DefectCorrection likely involves a significant expense
Concern typeRepair/ReplaceRecommend repairing or replacing
Concern typeRepair/MaintainRecommend repair and/or maintenance
Concern typeMinor DefectCorrection likely involves only a minor expense
Concern typeMaintainRecommend ongoing maintenance
Concern typeEvaluateRecommend evaluation by a specialist
Concern typeCommentFor your information
Concern typeInfestationEvidence of infestation of wood destroying insects or organisms (Live or dead insect bodies, fungal growth, etc.)
Concern typeConducive conditionsConditions conducive for wood destroying insects or organisms (Wood-soil contact, shrubs in contact with siding, roof or plumbing leaks, etc.)

Click here for a glossary of building construction terms.Contact your inspector If there are terms that you do not understand, or visit the glossary of construction terms at https://www.reporthost.com/glossary.asp

Table of Contents

General Information
Grounds
Exterior and Foundation
Roof
Attic and Roof Structure
Garage or Carport
Electric
Plumbing / Fuel Systems
Water Heater
Heating, Ventilation and Air Condition (HVAC)
Fireplaces, Stoves, Chimneys and Flues
Kitchen
Bathrooms, Laundry and Sinks
Interior, Doors and Windows
Wood Destroying Organism Findings
View summary

General InformationTable of contents
Report number: 800
Time started: 0930
Time finished: 1145
Present during inspection: Realtor
Client present for discussion at end of inspection: Yes
Weather conditions during inspection: Dry (no rain)
Temperature during inspection: Warm
Inspection fee: 325.00
Payment method: ZELLE
Type of building: Single family, Multiplex
Buildings inspected: One house
Number of residential units inspected: 1
Age of main building: 19954
Source for main building age: Municipal records or property listing
Front of building faces: East
Main entrance faces: East
Occupied: No
1)  Based on substandard construction observed, modifications to this property may have been made without the owner having attained permits or inspections from the municipality. Work may have been performed by someone other than a qualified contractor or person. Consult with the property owner about this, and if necessary research permits.

At worst case, if substantial work was performed without permits, this knowledge must be disclosed when the building is sold in the future. This can adversely affect future sales. Also, the local municipality could require costly alterations to bring the building into legal compliance or even require that the additions or modifications be removed.

THE SEPTIC TANK WAS FULL OF HUMAN WASTE. Unknown if residence was converted to City sewer or of septic tanks were removed.

THE GARAGE WAS CONVERTED INTO A ROOM.
Cost estimate: $125.00 Service call
Photo
Photo 1-1 It is unclear whether the septic system was converted to the City of Hollywood sewer system or not. Verification is needed to confirm the same.
Photo
Photo 1-2 It is unclear whether the septic system was converted to the City of Hollywood sewer system or not. Verification is needed to confirm the same.
Photo
Photo 1-3 It is unclear whether the septic system was converted to the City of Hollywood sewer system. Verification is needed to confirm the same.
Unscrewed sewer caps had large amounts of human waste, flies, and foul order.
Septic must be pumped and cleaned before making occupancy to the residence.
Photo
Photo 1-4 The garage was converted into a room
2)  Structures built prior to the mid 1980s may contain lead and/or asbestos. Lead is commonly found in paint and in some plumbing components. The EPA does not recognize newer coats of paint as encapsulating older coats of lead-based paint. Asbestos is commonly found in various building materials such as insulation, siding, and/or floor and ceiling tiles. Laws were passed in 1978 to prohibit usage of lead and asbestos, but stocks of materials containing these substances remained in use for a number of years thereafter. Both lead and asbestos are known health hazards. Evaluating for the presence of lead and/or asbestos is beyond the scope of this inspection. Any mention of these materials in this report is made as a courtesy only, and meant to refer the client to a specialist. Consult with specialists as necessary, such as industrial hygienists, professional labs and/or abatement specialists for this type of evaluation. For information on lead, asbestos and other hazardous materials in homes, visit:
http://www.reporthost.com/?EPA
http://www.reporthost.com/?CPSC
http://www.reporthost.com/?CDC
Limitations: Unless specifically included in the inspection, the following items and any related equipment, controls, electric systems and/or plumbing systems are excluded from this inspection: detached buildings or structures; fences and gates; retaining walls; underground drainage systems, catch basins or concealed sump pumps; swimming pools and related safety equipment, spas, hot tubs or saunas; whether deck, balcony and/or stair membranes are watertight; trees, landscaping, properties of soil, soil stability, erosion and erosion control; ponds, water features, irrigation or yard sprinkler systems; sport courts, playground, recreation or leisure equipment; areas below the exterior structures with less than 3 feet of vertical clearance; invisible fencing; sea walls, docks and boathouses; retractable awnings. Any comments made regarding these items are as a courtesy only.
Site profile: Level
Condition of driveway: Appeared serviceable
Driveway material: Brick
Condition of sidewalks and/or patios: Appeared serviceable
Sidewalk material: Paving stones
Condition of deck, patio and/or porch covers: Appeared serviceable
Deck, patio, porch cover material and type: Open
Condition of decks, porches and/or balconies: Appeared serviceable
Deck, porch and/or balcony material: Wood
Exterior and FoundationTable of contents
Limitations: The inspector performs a visual inspection of accessible components or systems at the exterior. Items excluded from this inspection include below-grade foundation walls and footings; foundations, exterior surfaces or components obscured by vegetation, stored items or debris; wall structures obscured by coverings such as siding or trim. Some items such as siding, trim, soffits, vents and windows are often high off the ground, and may be viewed using binoculars from the ground or from a ladder. This may limit a full evaluation. Regarding foundations, some amount of cracking is normal in concrete slabs and foundation walls due to shrinkage and drying. Note that the inspector does not determine the adequacy of seismic reinforcement.
Wall inspection method: Viewed from ground
Condition of wall exterior covering: Appeared serviceable
Apparent wall structure: Concrete block
Wall covering: Stucco
Condition of foundation and footings: Appeared serviceable
Apparent foundation type: Concrete slab on grade
Foundation/stem wall material: Poured in place concrete, Concrete block
Footing material (under foundation stem wall): Poured in place concrete, Pre-cast concrete
3)  Some sections of siding and/or trim were deteriorated and/or rotten. Recommend that a qualified person repair, replace or install siding or trim as necessary.

The tiki hut was located over the back part of the roof, causing rainwater to accumulate in the gutter and leading to rot in the flashing and soffits.

Significant amounts of debris have accumulated in one or more gutters or downspouts. Gutters can overflow and cause water to come in contact with the building exterior, or water can accumulate around the foundation. This is a conducive condition for wood-destroying organisms. Recommend cleaning gutters and downspouts now and as necessary in the future.
Cost estimate: $800.00
Photo
Photo 3-1 The tiki hut at the back of the house has caused damage to the roof as it overlaps, leading to the rotting of the flashing and soffit.
Photo
Photo 3-2 The tiki hut at the back of the house has caused damage to the roof as it overlaps, leading to the rotting of the flashing and soffit.
Photo
Photo 3-3 The tiki hut at the back of the house has caused damage to the roof as it overlaps, leading to the rotting of the flashing and soffit.
Photo
Photo 3-4 The tiki hut at the back of the house has caused damage to the roof as it overlaps, leading to the rotting of the flashing and soffit.
4)  One exterior outlet was missing the safety face plate.
Cost estimate: $125.00 Service call
Photo
Photo 4-1 The safety plate was missing from an exterior electrical outlet.
Photo
Photo 4-2 The safety plate was missing from an exterior electrical outlet.
5)  The cleanout cap prevents sewage backflow and protects your home from harmful gases and foul smells. The cap's primary function is to create a closed plumbing system – containing the gases naturally accumulated in plumbing pipes.
Cost estimate: $10.00
Photo
Photo 5-1 The sewer cleaner cap was missing.
Photo
Photo 5-2 The sewer cleaner cap was missing.
6) Conducive conditions Trees were in contact with or were close to the building at one or more locations. Damage to the building can occur, especially during high winds, or may have already occurred (see other comments in this report). Recommend that a qualified tree service contractor or certified arborist remove trees as necessary to prevent damage to the building exterior.

One or more large trees were very close to the foundation. Tree roots can cause significant structural damage to foundations, or may have already caused damage (see other comments in this report). Recommend that a qualified tree service contractor or certified arborist remove trees as necessary to prevent damage to foundations.
Cost estimate: $1,200.00
Photo
Photo 6-1 The palm tree needs to be removed and the stump grinded to prevent damage to the roof and foundation.
Photo
Photo 6-2 The palm tree needs to be removed and the stump grinded to prevent damage to the roof and foundation.
Photo
Photo 6-3 The palm tree needs to be removed and the stump grinded to prevent damage to the roof and foundation.
Limitations: The following items or areas are not included in this inspection: areas that could not be traversed or viewed clearly due to lack of access; solar roofing components. Any comments made regarding these items are made as a courtesy only. Note that the inspector does not provide an estimate of remaining life on the roof surface material, nor guarantee that leaks have not occurred in the roof surface, skylights or roof penetrations in the past. Regarding roof leaks, only active leaks, visible evidence of possible sources of leaks, and evidence of past leaks observed during the inspection are reported on as part of this inspection. The inspector does not guarantee or warrant that leaks will not occur in the future. Complete access to all roof and attic spaces during all seasons and during prolonged periods of all types of weather conditions (e.g. high wind and rain, melting snow) would be needed to do so. Occupants should monitor the condition of roofing materials in the future. For older roofs, recommend that a professional inspect the roof surface, flashings, appurtenances, etc. annually and maintain/repair as might be required. If needed, the roofer should enter attic space(s). Regarding the roof drainage system, unless the inspection was conducted during and after prolonged periods of heavy rain, the inspector was unable to determine if gutters, downspouts and extensions perform adequately or are leak-free.
Roof inspection method: Partially traversed, Viewed from eaves on ladder
Condition of roof surface material: Appeared serviceable
Roof surface material: Clay tile
Roof type: Gable
Condition of exposed flashings: Appeared serviceable
Condition of gutters, downspouts and extensions: Appeared serviceable
Attic and Roof StructureTable of contents
Limitations: The following items or areas are not included in this inspection: areas that could not be traversed or viewed clearly due to lack of access; areas and components obscured by insulation. Any comments made regarding these items are made as a courtesy only. The inspector does not determine the adequacy of the attic ventilation system. Complete access to all roof and attic spaces during all seasons and during prolonged periods of all types of weather conditions (e.g. high/low temperatures, high/low humidity, high wind and rain, melting snow) would be needed to do so. The inspector is not a licensed engineer and does not determine the adequacy of roof structure components such as trusses, rafters or ceiling beams, or their spacing or sizing.
Attic inspection method: Viewed from hatch(es)
Condition of roof structure: Appeared serviceable
Roof structure type: Trusses, Rafters
Ceiling structure: Trusses, Ceiling joists, Ceiling beams
Condition of insulation in attic (ceiling, skylight chase, etc.): Appeared serviceable
Ceiling insulation material: Cellulose loose fill
Approximate attic insulation R value (may vary in areas): R-38
Vapor retarder: Installed
Condition of roof ventilation: Appeared serviceable
Roof ventilation type: Mechanical vents with powered fan
Garage or CarportTable of contents
Limitations: The inspector cannot reasonably determine the integrity of all elements of limited fire resistance at residential construction or verify firewall ratings at multi unit construction. Requirements for ventilation in garages vary between municipalities. The garage was converted into a room.
Limitations: The following items are not included in this inspection: generator systems, transfer switches, surge suppressors, inaccessible or concealed wiring; underground utilities and systems; low-voltage lighting or lighting on timers or sensors. Any comments made regarding these items are as a courtesy only. Note that the inspector does not determine the adequacy of grounding or bonding, if this system has an adequate capacity for the client's specific or anticipated needs, or if this system has any reserve capacity for additions or expansion. The inspector does not operate circuit breakers as part of the inspection, and does not install or change light bulbs. The inspector does not evaluate every wall switch or receptacle, but instead tests a representative number of them per various standards of practice. When furnishings, stored items or child-protective caps are present some receptacles are usually inaccessible and are not tested; these are excluded from this inspection. Receptacles that are not of standard 110 volt configuration, including 240-volt dryer receptacles, are not tested and are excluded. The functionality of, power source for and placement of smoke and carbon monoxide alarms is not determined as part of this inspection. Upon taking occupancy, proper operating and placement of smoke and carbon monoxide alarms should be verified and batteries should be changed. These devices have a limited lifespan and should be replaced every 10 years. The inspector attempts to locate and evaluate all main and sub-panels. However, panels are often concealed. If panels are found after the inspection, a qualified electrician should evaluate and repair if necessary. The inspector attempts to determine the overall electrical service size, but such estimates are not guaranteed because the overall capacity may be diminished by lesser-rated components in the system. Any repairs recommended should be made by a licensed electrician.
Electric service condition: Required repair, replacement and/or evaluation (see comments below)
Primary service type: Overhead
Number of service conductors: 2
Service voltage (volts): 120-240, 3 phase, 4 wire, 120
Estimated service amperage: 200
Primary service overload protection type: Circuit breakers, Fuses
Service entrance conductor material: Stranded aluminum
Main disconnect rating (amps): 200
System ground: Cold water supply pipes
Condition of main service panel: Appeared serviceable
Condition of sub-panel(s): Appeared serviceable
Location of main service panel #A: Building exterior
Location of main service panel #B: Laundry room
Location of main disconnect: Breaker at top of main service panel
Condition of branch circuit wiring: Serviceable
Branch circuit wiring type: copper
Solid strand aluminum branch circuit wiring present: None visible
Ground fault circuit interrupter (GFCI) protection present: Yes
Arc fault circuit interrupter (AFCI) protection present: Yes
Smoke alarms installed: Yes, but not tested
Carbon monoxide alarms installed: Yes, but not tested
7)  The service drop wires were less than 10 feet above the ground, a deck, or walkways. This is a shock hazard. A qualified electrician or utility company should repair per standard building practices.


The point of attachment of the overhead service conductors to a building or other structure shall provide the minimum clearances as specified in 230.9 and 230.24. In no case shall this point of attachment be less than 3.0 m (10 ft) above the finished grade.
Cost estimate: $125.00 service call
Photo
Photo 7-1 The service lines must be at least 10' above any hard surface.
Photo
Photo 7-2 The service lines must be at least 10' above any hard surface.
Photo
Photo 7-3 The service lines must be at least 10' above any hard surface, and they were in direct contact with the rain gutter.
Photo
Photo 7-4 The service lines must be at least 10' above any hard surface, and they were in direct contact with the rain gutter.
Photo
Photo 7-5 The service lines must be at least 10' above any hard surface, and they were in direct contact with the rain gutter.
Photo
Photo 7-6 The service lines must be at least 10' above any hard surface, and they were in direct contact with the rain gutter.
8)  The condition of these panel(s) is unknown and they are excluded from this inspection. Repairs may be needed. Recommend that a qualified person correct conditions, or that a qualified contractor make repairs if necessary so panels can be opened, and that a qualified person fully evaluate panel(s).

***Recommend getting full knowledge and how to engage and disengage the stand-alone generator and the electrical components.
Cost estimate: $125.00 Service call
Photo
Photo 8-1 Before residents move in, it is important to test the generator and electrical system.
Photo
Photo 8-2 Before residents move in, it is important to test the generator and electrical system.
Photo
Photo 8-3 Before residents move in, it is important to test the generator and electrical system.
Photo
Photo 8-4 Before residents move in, it is important to test the generator and electrical system.
Photo
Photo 8-5 Before residents move in, it is important to test the generator and electrical system.
Photo
Photo 8-6 Before residents move in, it is important to test the generator and electrical system.
9)  Neutral wires were doubled or bundled together under the same lug on the neutral bus bar in panel(s) #C. This is a potential safety hazard in the event that one of the circuits needs to be isolated during servicing. For one neutral to be disconnected, other neutrals from energized circuits sharing the same lug will be loosened. Power surges may result on the energized circuits and result in damage or fire. Also, multiple wires under the same lug may not be secure, resulting in loose wires, arcing, sparks and fire. Recommend that a qualified electrician repair per standard building practices. For more information, visit:
http://www.reporthost.com/?DTNB
Cost estimate: $125.00 Service call
Photo
Photo 9-1 A double tap was noted on the neutral bus bar.
10)  One or more smoke alarms were missing, damaged, or missing components. Smoke alarms should be replaced as necessary. For more information, visit:
http://www.reporthost.com/?SMKALRM
Cost estimate: $50.00
Photo
Photo 10-1 Recommend replacing all missing smoke detectors.
11)  Using electrical outlet without a cover plate or faceplate is not safe. Cover plates and faceplates are designed to protect the electrical wiring and components inside the outlet, as well as to prevent accidental contact with live wires.
Cost estimate: $10.00
Photo
Photo 11-1 The electrical face plate was missing from under the sink.
Photo
Photo 11-2 The electrical face plate was missing from under the sink.
12)  Branch circuit wiring installed in buildings built prior to the mid 1980s is typically rated for a maximum temperature of only 60 degrees Celsius. This includes non-metallic sheathed (Romex) wiring, and both BX and AC metal-clad flexible wiring. Knob and tube wiring, typically installed in homes built prior to 1950, may be rated for even lower maximum temperatures. Newer electric fixtures including lighting and fans typically require wiring rated for 90 degrees Celsius. Connecting newer fixtures to older, 60-degree-rated wiring is a potential fire hazard. Repairs for such conditions may involve replacing the last few feet of wiring to newer fixtures with new 90-degree-rated wire, and installing a junction box to join the old and new wiring.

It is beyond the scope of this inspection to determine if such incompatible components are installed, or to determine the extent to which they're installed. Based on the age of this building, the client should be aware of this safety hazard, both for existing fixtures and when planning to upgrade with newer fixtures. Consult with a qualified electrician for repairs as necessary.
13)  Since electrical energy can be a significant hazard, using blunt-tipped screws is an extremely important and easy way to prevent injury or death when working around electrical panels. If your electrical panel contains sharp-tipped screws, do not screw this back into the panel as they could come in contact with wiring.

Keeping unused breakers in place may limit the capacity for future expansion or modifications to the electrical system. It's generally best to remove unused breakers and properly cap off the corresponding wires for safety and clarity.

Cost estimate: $25.00
Photo
Photo 13-1 The electrical panel was missing screws, and the wrong screws were being used.
Photo
Photo 13-2 The electrical panel was missing screws, and the wrong screws were being used.
Photo
Photo 13-3 The electrical panel was missing screws, and the wrong screws were being used.
Photo
Photo 13-4 The electrical panel was missing screws, and the wrong screws were being used.
Photo
Photo 13-5 Recommend removing any unused breakers in the panel.
Photo
Photo 13-6 Recommend removing any unused breakers in the panel.
Photo
Photo 13-7 Loose wires were noted in the electrical panel. Recommend either connecting them to the proper breaker, or capping them.
Plumbing / Fuel SystemsTable of contents
Limitations: The following items are not included in this inspection: private/shared wells and related equipment; private sewage disposal systems; hot tubs or spas; main, side and lateral sewer lines; gray water systems; pressure boosting systems; trap primers; incinerating or composting toilets; fire suppression systems; water softeners, conditioners or filtering systems; plumbing components concealed within the foundation or building structure, or in inaccessible areas such as below tubs; underground utilities and systems; overflow drains for tubs and sinks; backflow prevention devices. Any comments made regarding these items are as a courtesy only. Note that the inspector does not operate water supply or shut-off valves due to the possibility of valves leaking or breaking when operated. The inspector does not test for lead in the water supply, the water pipes or solder, does not determine if plumbing and fuel lines are adequately sized, and does not determine the existence or condition of underground or above-ground fuel tanks.
Condition of service and main line: Appeared serviceable
Water service: Public
Location of main water shut-off: Building exterior
Condition of supply lines: Appeared serviceable
Supply pipe material: Copper
Condition of drain pipes: Appeared serviceable
Drain pipe material: Plastic
Condition of waste lines: Appeared serviceable
Waste pipe material: Plastic
Vent pipe condition: Appeared serviceable
Vent pipe material: Galvanized steel
Sump pump installed: No
Sewage ejector pump installed: No
Type of irrigation system supply source: Public
14)  Rusted or corroded gas lines should always be addressed immediately. Because rust or corrosion on your gas lines will quickly spread, replacement is the best solution. This is because the metal has already begun to weaken. Recommend a qualified company replace the valve.
**NO GAS LEAK WAS DETECTED.
Cost estimate: $125.00 Service call
Photo
Photo 14-1 Corrosion was observed on the gas pipe, but no leaks were detected.
Photo
Photo 14-2 Corrosion was observed on the gas pipe, but no leaks were detected.
15)   How important is a water softener?
The mineral ions in hard water prevent it from dissolving soaps properly. Homes with a water softener enjoy a better lather and a better bathing experience. Softened water also eliminates the harmful effects hard water has on your body due to the destruction of natural oils in your skin and hair.
It also prevents the build-up of minerals (scale) on the inside of pipes, fixtures, and water heaters. Lengthens the life of some appliances. Reduces or prevents mineral spots on glassware. Prevents or reduces soap films and detergent curds in sinks, bathtubs, and washing machines.


Cost estimate: $125.00 Service call
Photo
Photo 15-1 The water softener system needs to be flushed and the holding tank requires cleaning.
Photo
Photo 15-2 The water softener system needs to be flushed and the holding tank requires cleaning.
Water HeaterTable of contents
Limitations: Evaluation of and determining the adequacy or completeness of the following items are not included in this inspection: water recirculation pumps; solar water heating systems; Energy Smart or energy saver controls; catch pan drains. Any comments made regarding these items are as a courtesy only. Note that the inspector does not provide an estimate of remaining life on water heaters, does not determine if water heaters are appropriately sized, or perform any evaluations that require a pilot light to be lit or a shut-off valve to be operated.
Condition of water heater: Appeared serviceable
Type: Tankless
Energy source: Propane
Estimated age: 6yrs
Temperature-pressure relief valve installed: Yes
Location of water heater: EXTERIOR WALL
Water temperature (degrees Fahrenheit): 114.4
Heating, Ventilation and Air Condition (HVAC)Table of contents
Limitations: The following items are not included in this inspection: humidifiers, dehumidifiers, electronic air filters; solar, coal or wood-fired heat systems; thermostat or temperature control accuracy and timed functions; heating components concealed within the building structure or in inaccessible areas; underground utilities and systems; safety devices and controls (due to automatic operation). Any comments made regarding these items are as a courtesy only. Note that the inspector does not provide an estimate of remaining life on heating or cooling system components, does not determine if heating or cooling systems are appropriately sized, does not test coolant pressure, or perform any evaluations that require a pilot light to be lit, a shut-off valve to be operated, a circuit breaker to be turned "on" or a serviceman's or oil emergency switch to be operated. It is beyond the scope of this inspection to determine if furnace heat exchangers are intact and free of leaks. Condensation pans and drain lines may clog or leak at any time and should be monitored while in operation in the future. Where buildings contain furnishings or stored items, the inspector may not be able to verify that a heat source is present in all "liveable" rooms (e.g. bedrooms, kitchens and living/dining rooms).
General heating system type(s): Forced air, Heat pump
General heating distribution type(s): Ducts and registers
Last service date of primary heat source: UNK
Condition of forced air heating/(cooling) system: Appeared serviceable
Forced air heating system fuel type: Electric
Location of forced air furnace: Attic
Forced air system capacity in BTUs or kilowatts: 48,000BTUS
Location for forced air filter(s): Behind return air grill(s)
Condition of forced air ducts and registers: Appeared serviceable
Condition of controls: Appeared serviceable
16)  The last service date of the forced air heating/cooling system appeared to be more than 1 year ago, or the inspector was unable to determine the last service date. Ask the property owner when it was last serviced. If unable to determine the last service date, or if this system was serviced more than 1 year ago, recommend that a qualified HVAC contractor service this system and make repairs if necessary. Because this system has a compressor and refrigerant system, this servicing should be performed annually in the future. Any needed repairs noted in this report should be brought to the attention of the contractor when it's serviced.
Cost estimate: $850.00
Photo
Photo 16-1 The air conditioning system requires servicing and straightening of the fins to improve its performance.
Photo
Photo 16-2 The air conditioning system requires servicing and straightening of the fins to improve its performance.
Photo
Photo 16-3 The air conditioning system requires servicing and straightening of the fins to improve its performance.
Fireplaces, Stoves, Chimneys and FluesTable of contents
Limitations: The following items are not included in this inspection: coal stoves, gas logs, chimney flues (except where visible). Any comments made regarding these items are as a courtesy only. Note that the inspector does not determine the adequacy of drafting or sizing in fireplace and stove flues, and also does not determine if prefabricated or zero-clearance fireplaces are installed in accordance with the manufacturer's specifications. The inspector does not perform any evaluations that require a pilot light to be lit, and does not light fires. The inspector provides a basic visual examination of a chimney and any associated wood burning device. The National Fire Protection Association has stated that an in-depth Level 2 chimney inspection should be part of every sale or transfer of property with a wood-burning device. Such an inspection may reveal defects that are not apparent to the home inspector who is a generalist.
Condition of wood-burning fireplaces, stoves: Required repair, replacement and/or evaluation (see comments below)
Wood-burning fireplace type: Masonry with metal liner
Wood-burning stove type: Attached
17)  The metal fireplace liner was rusty. Significant rust can cause holes in metal. Fireplaces with metal liners typically circulate indoor air behind the firebox and act as a "heatilator" where warmed air is blown or drawn back into the living area. When holes form in liners, smoke and combustion gases can enter the heatilator chamber and living spaces. This is a potential safety hazard. Recommend that a qualified specialist evaluate and repair if necessary.

One or more solid fuel-burning fireplaces or stoves were found at the property. When such devices are used, they should be professionally inspected and cleaned annually to prevent creosote build-up and to determine if repairs are needed. The National Fire Protection Association states that a "Level 2" chimney inspection should be performed with every sale or transfer of property with a wood-burning device. Recommend consulting with the property owner about recent and past servicing and repairs to all wood-burning devices and chimneys or flues at this property. Recommend that a qualified specialist evaluate all solid fuel-burning devices and chimneys, and clean and repair as necessary. Note that if a wood stove insert is installed, it may need to be removed for such an evaluation. For more information, search for "chimney inspection" at:
http://www.reporthost.com/?CSIA

Holes or cracks were found in the metal fireplace liner. Fireplaces with metal liners typically circulate indoor air behind the firebox and act as a "heatilator" where warmed air is blown or drawn back into the living area. When holes or cracks form in liners, smoke and combustion gases can enter the heatilator chamber and living spaces. This is a potential safety hazard. Recommend that a qualified specialist evaluate and repair if necessary.


Cost estimate: $125.00 Service call
Photo
Photo 17-1 It is crucial to repair and service the fireplace before burning any wood to ensure safety and prevent any potential hazards.
Photo
Photo 17-2 It is crucial to repair and service the fireplace before burning any wood to ensure safety and prevent any potential hazards.
**Large amounts of rust were noted in the chimney.
Photo
Photo 17-3 It is crucial to repair and service the fireplace before burning any wood to ensure safety and prevent any potential hazards.
**Large amounts of rust were noted in the chimney.
Photo
Photo 17-4 It is crucial to repair and service the fireplace before burning any wood to ensure safety and prevent any potential hazards.
**Large amounts of rust were noted in the chimney.
Limitations: The following items are not included in this inspection: household appliances such as stoves, ovens, cook tops, ranges, warming ovens, griddles, broilers, dishwashers, trash compactors, refrigerators, freezers, ice makers, hot water dispensers and water filters; appliance timers, clocks, cook functions, self and/or continuous cleaning operations, thermostat or temperature control accuracy, and lights. Any comments made regarding these items are as a courtesy only. Note that the inspector does not provide an estimate of the remaining life of appliances, and does not determine the adequacy of operation of appliances. The inspector does not note appliance manufacturers, models or serial numbers and does not determine if appliances are subject to recalls. Areas and components behind and obscured by appliances are inaccessible and excluded from this inspection.
Condition of counters: Appeared serviceable
Condition of cabinets: Appeared serviceable
Condition of sinks and related plumbing: Appeared serviceable
Condition of under-sink food disposal: Appeared serviceable
Condition of ranges, cooktops and/or ovens: Appeared serviceable
Range, cooktop, oven type: Propane
Type of ventilation: Hood or built into microwave over range or cooktop
Condition of refrigerator: Appeared serviceable
Condition of built-in microwave oven: Appeared serviceable
18)  Countertops and/or backsplashes were damaged or deteriorated. Recommend repairing or replacing as necessary.
Cost estimate: $125.00 Service call
Photo
Photo 18-1 A tile was missing from the back splash in the kitchen.
Photo
Photo 18-2 A tile was missing from the back splash in the kitchen.
19)  Changes to the 2020 NEC required at least one receptacle outlet to be installed in all islands and peninsulas, and potentially more depending on the overall square footage of the countertop or work surface for the island or peninsula.
Cost estimate: $125.00 Service call
Photo
Photo 19-1 The kitchen island was on casters and did not have any electrical outlets.
Bathrooms, Laundry and SinksTable of contents
Limitations: The following items are not included in this inspection: overflow drains for tubs and sinks; heated towel racks, saunas, steam generators, clothes washers, clothes dryers. Any comments made regarding these items are as a courtesy only. Note that the inspector does not determine the adequacy of washing machine drain lines, washing machine catch pan drain lines, or clothes dryer exhaust ducts. The inspector does not operate water supply or shut-off valves for sinks, toilets, bidets, clothes washers, etc. due to the possibility of valves leaking or breaking when operated. The inspector does not determine if shower pans or tub and shower enclosures are water tight, or determine the completeness or operability of any gas piping to laundry appliances.
Location #A: Master bath
Location #B: Full bath
Condition of counters: Appeared serviceable
Condition of cabinets: Appeared serviceable
Condition of flooring: Appeared serviceable
Condition of sinks and related plumbing: Appeared serviceable
Condition of toilets: Appeared serviceable
Condition of bathtubs and related plumbing: Appeared serviceable
Condition of shower(s) and related plumbing: Appeared serviceable
Condition of ventilation systems: Appeared serviceable
Bathroom and laundry ventilation type: Windows, Central exhaust fan
Gas supply for laundry equipment present: Yes
240 volt receptacle for laundry equipment present: No
20) Conducive conditions One or more missing handles were found at water shut-off valves for the sink at location(s) #B and/or missing. A qualified plumber should repair as necessary.
Cost estimate: $125.00 Service call
Photo
Photo 20-1 The shutoff valve handles were missing.
Photo
Photo 20-2 The shutoff valve handles were missing.
21)  Duct joints shall be installed so that the male end of the duct points in the direction of the airflow. Joints should be secured with metal tape (not duct tape). Do not use rivets or screws in the joints or anywhere else in the duct as these will encourage lint collection.
Cost estimate: $0.00
Photo
Photo 21-1 Please make sure to properly attach the dryer vent to prevent any potential leaks.
22)  One or more bathtub faucet handles at location(s) #A were loose. Recommend that a qualified person repair or replace handles as necessary.

The shower head was not engaging.
Cost estimate: $125.00 Service call
Photo
Photo 22-1 The diverter valve located in the main bathroom shower is broken and requires repair.
Photo
Photo 22-2 The diverter valve located in the main bathroom shower is broken and requires repair.
Photo
Photo 22-3 The drain plug needs to be installed in the master bathroom tub.
Photo
Photo 22-4 The drain plug needs to be installed in the master bathroom tub.
23)  The clothes washer drain standpipe was too short. Standard building practices require that the stand pipe be:
  • A minimum of 2 inches in diameter
  • At least 33 inches tall for a top-loading clothes washer
  • At least 24 inches tall for a front-loading clothes washer
Recommend that a qualified person repair as necessary per standard building practices.
Cost estimate: $125.00 Service call
Photo
Photo 23-1 The washing machine was not inspected and was disconnected. It is recommended to operate the washer first to ensure there are no active leaks.
Photo
Photo 23-2 The washing machine was not inspected and was disconnected. It is recommended to operate the washer first to ensure there are no active leaks, due to the drain pipe being so low.
24)  The shower head at location(s) #B was dripping when the shower was being operated, and the faucet was loose. Recommend that a qualified person repair as necessary.
Cost estimate: $125.00 Service call
Photo
Photo 24-1 The shower faucet was loose and needs to be secured to prevent water intrusion.
Photo
Photo 24-2 The shower faucet was loose and needs to be secured to prevent water intrusion.
Photo
Photo 24-3 The shower head has a continuous leak, and needs to be repaired.
Interior, Doors and WindowsTable of contents
Limitations: The following items are not included in this inspection: security, intercom and sound systems; communications wiring; central vacuum systems; elevators and stair lifts; cosmetic deficiencies such as nail-pops, scuff marks, dents, dings, blemishes or issues due to normal wear and tear in wall, floor and ceiling surfaces and coverings, or in equipment; deficiencies relating to interior decorating; low voltage and gas lighting systems. Any comments made regarding these items are as a courtesy only. Note that the inspector does not evaluate any areas or items which require moving stored items, furnishings, debris, equipment, floor coverings, insulation or similar materials. The inspector does not test for asbestos, lead, radon, mold, hazardous waste, urea formaldehyde urethane, or any other toxic substance. Some items such as window, drawer, cabinet door or closet door operability are tested on a sampled basis. The client should be aware that paint may obscure wall and ceiling defects, floor coverings may obscure floor defects, and furnishings may obscure wall, floor and floor covering defects. If furnishings were present during the inspection, recommend a full evaluation of walls, floors and ceilings that were previously obscured when possible. Carpeting and flooring, when installed over concrete slabs, may conceal moisture. If dampness wicks through a slab and is hidden by floor coverings that moisture can result in unhygienic conditions, odors or problems that will only be discovered when/if the flooring is removed. Determining the cause and/or source of odors is not within the scope of this inspection.
Condition of exterior entry doors: Appeared serviceable
Exterior door material: Fiberglass or vinyl, Glass panel
Condition of interior doors: Appeared serviceable
Condition of windows and skylights: Appeared serviceable
Type(s) of windows: Metal, Multi-pane
Condition of walls and ceilings: Appeared serviceable
Wall type or covering: Drywall
Ceiling type or covering: Plaster
Condition of flooring: Appeared serviceable
Flooring type or covering: Tile
25)  Screens were missing from some windows. These windows may not provide ventilation during months when insects are active.

Several blinds were broken from the rear door.
Cost estimate: $125.00 Service call
Photo
Photo 25-1 Several windows screens were missing from windows.
Photo
Photo 25-2 Several blinds were missing from the Bahama shutters
Photo
Photo 25-3 Several blinds were missing from the Bahama shutters
Photo
Photo 25-4 Several blinds were missing from the Bahama shutters
26)  One or more walls were damaged and/or had substandard repairs. Recommend that a qualified person repair as necessary.
Cost estimate: $125.00 Service call
Photo
Photo 26-1 Old water damage was noted on the living room wall. 20% moisture was detected.
Photo
Photo 26-2 Old water damage was noted on the living room wall. 20% moisture was detected.
27)  No switches or controls were noted to control the ceiling fans. Recommend asking the home owner if they are remote controlled.
Cost estimate: $0.00
Photo
Photo 27-1 There was no switch available to operate the ceiling fans in the bedroom.
*Master bedroom
Photo
Photo 27-2 There was no switch available to operate the ceiling fans in the bedroom.
*Second bedroom
Photo
Photo 27-3 There was no switch available to operate the ceiling fans in the bedroom.
*Living room.
28)   A well-lit closet is easy to navigate and organize, and feels more accessible. Closet lighting can be more than just functional – a well-lit closet looks better, too. On the other hand, a dark closet is difficult to use, and difficult to declutter, and you can easily lose items within it.
Cost estimate: $125.00 Service call
Photo
Photo 28-1 The lights inside the closet of the second bedroom are not functioning.
Photo
Photo 28-2 The lights inside the closet of the second bedroom are not functioning.
Wood Destroying Organism FindingsTable of contents
Limitations: This report only includes findings from accessible and visible areas on the day of the inspection. In addition to the inaccessible areas documented in this report, examples of other inaccessible areas include: sub areas less than 18 inches in height; attic areas less than 5 feet in height, areas blocked by ducts, pipes or insulation; areas where locks or permanently attached covers prevent access; areas where insulation would be damaged if traversed; areas obscured by vegetation. All inaccessible areas are subject to infestation or damage from wood-destroying organisms. The inspector does not move furnishings, stored items, debris, floor or wall coverings, insulation, or other materials as part of the inspection, nor perform destructive testing. Wood-destroying organisms may infest, re-infest or become active at any time. No warranty is provided as part of this inspection.
Visible evidence of active wood-destroying insects: No
Visible evidence of active wood decay fungi: No
Visible evidence of past wood-destroying insects: Yes
Visible evidence of past wood decay fungi: No
Visible evidence of damage by wood-destroying insects: No
Visible evidence of damage by wood decay fungi: No
Visible evidence of conditions conducive to wood-destroying organisms: No
Evidence of prior treatment of wood-destroying insects: Label in the attic
29) Infestation Evidence of past infestation of drywood termites was found at location(s) #Attic in the form of fecal pellets with no visible wood damage. Recommend the following:
  • Correct any conducive conditions for wood-destroying organisms mentioned in this report.
  • Consult with the property owner about any history of infestation.
  • Have a state-licensed pest control operator evaluate further and treat as necessary.

Cost estimate: $125.00 Service call
Photo
Photo 29-1 A label was found in the attic indicating that a termite inspection had been conducted recently.
Photo
Photo 29-2 A large amount of termite pellets were found in the attic. No active or dead termites were seen.
Photo
Photo 29-3 A large amount of termite pellets were found in the attic. No active or dead termites were seen.