Summary
Unofficial version!

Client(s): Suhail Aslam
Property address: 397 Split Rock Rd
Syosset NY 11791-1509
Inspection date: Sunday, May 4, 2025

This report published on Sunday, May 4, 2025 8:51:21 PM EDT

This report is the exclusive property of this inspection company and the client(s) listed in the report title. Use of this report by any unauthorized persons is prohibited.

Concerns are shown and sorted according to these types:
Concern typeSafetyPoses a safety hazard
Concern typeRepair/ReplaceRecommend repairing or replacing
Concern typeRepair/MaintainRecommend repair and/or maintenance
Concern typeMinor DefectCorrection likely involves only a minor expense
Concern typeMaintainRecommend ongoing maintenance
Concern typeEvaluateRecommend evaluation by a specialist
Concern typeCommentFor your information

Grounds
1)  Guardrails at one or more locations with drop-offs higher than 30 inches were deteriorated, and pose a fall hazard. Recommend that a qualified person repair guardrails as necessary.
Photo
Photo 1-1 
Photo
Photo 1-2 
2)  Wood rot was found in decking boards at one or more decks or porches. Recommend that a qualified contractor evaluate and repair as necessary. All rotten wood should be replaced.

Recommend removing the loose paint by scraping or sanding and
then paint to protect the wood from the elements.
Photo
Photo 2-1 
Photo
Photo 2-2 
Photo
Photo 2-3 
Photo
Photo 2-4 
Photo
Photo 2-5 
Photo
Photo 2-6 
Photo
Photo 2-7 
Photo
Photo 2-8 
Photo
Photo 2-9 
Photo
Photo 2-10 
Photo
Photo 2-11 
Photo
Photo 2-12 
Photo
Photo 2-13 
Photo
Photo 2-14 
Photo
Photo 2-15 
Photo
Photo 2-16 
Photo
Photo 2-17 
Photo
Photo 2-18 
3)  Cracks, holes, settlement, heaving and/or deterioration were found in driveways and/or parking areas. Recommend that qualified contractor repair as necessary.
Photo
Photo 3-1 
Photo
Photo 3-2 
4)  Recommend that the deck be prepped and painted to protect against the elements.
Photo
Photo 4-1 
Photo
Photo 4-2 
5)  Minor deterioration (e.g. cracks, holes, settlement, heaving) was found in driveways and/or parking areas, but no trip hazards were found. The client may wish to have repairs made for cosmetic reasons.
Photo
Photo 5-1 
Photo
Photo 5-2 
6)  Side panel by steps is rotted. Recommend replacing and protecting from the elements with several coats of a exterior paint or epoxy based paint.
Photo
Photo 6-1 
7)  majority of the asphalt is in a healthy condition.
Photo
Photo 7-1 
Photo
Photo 7-2 
Photo
Photo 7-3 
Photo
Photo 7-4 
Exterior and Foundations
8)  Some sections of siding and/or trim were damaged. Recommend that a qualified person repair, replace or install siding or trim as necessary.
Photo
Photo 8-1 
Photo
Photo 8-2 
Photo
Photo 8-3 
Photo
Photo 8-4 
Photo
Photo 8-5 
9)  Minor crack in the foundation. Recommend that this be repaired before winter. If water were to enter and freeze, it cause additional damage.
https://tinyurl.com/dryloccaulk
Photo
Photo 9-1 
10)  Vegetation such as trees, shrubs and/or vines was in contact with or close to the building exterior. Vegetation can serve as a pathway for wood-destroying insects and can retain moisture against the exterior after it rains. This is a conducive condition for wood-destroying organisms. Recommend pruning, moving or removing vegetation as necessary to maintain at least 6 inches of space between it and the building exterior. A 1-foot clearance is better.
Photo
Photo 10-1 
Photo
Photo 10-2 
Photo
Photo 10-3 
Photo
Photo 10-4 
Photo
Photo 10-5 
Photo
Photo 10-6 
Photo
Photo 10-7 
Photo
Photo 10-8 
11)  The paint or stain finish over much of the entire structure was failing (e.g. peeling, faded, worn, thinning). Siding and trim with a failing finish can be damaged by moisture. Recommend that a qualified contractor prep (e.g. clean, scrape, sand, prime, caulk) and repaint or restain the entire building exterior per standard building practices. Any repairs needed to the siding or trim should be made prior to this.
Photo
Photo 11-1 
Photo
Photo 11-2 
Photo
Photo 11-3 
Photo
Photo 11-4 
Photo
Photo 11-5 
Photo
Photo 11-6 
Photo
Photo 11-7 
Photo
Photo 11-8 
Photo
Photo 11-9 
Photo
Photo 11-10 
Photo
Photo 11-11 
12)  Cement pad on the side of the home is damaged and a section has been broken off. Recommend that the pad be repaired or replaced.
Photo
Photo 12-1 
Basements
13)  Handrails at one or more flights of stairs were missing. This is a potential fall hazard. Handrails should be installed at stairs with four or more risers or where stairs are greater than 30 inches high. Recommend that a qualified contractor install handrails where missing and per standard building practices.
Photo
Photo 13-1 
14)  Spalling on cement walls, also known as concrete spalling, refers to the deterioration of the concrete surface where it flakes, chips, peels, or breaks away. This can happen due to various factors, including water damage, or freeze-thaw cycles.

No signs of elevated moisture levels at the time of the inspection.

Repairing Spalling:

Patching:
Small spalls can often be repaired by patching with a suitable concrete repair material.

Resurfacing:
For more extensive spalling, concrete resurfacing or overlaying can be used to restore the surface.

Professional Repair:
In severe cases, professional repair may be necessary to address structural damage.
Photo
Photo 14-1 
Photo
Photo 14-2 
Photo
Photo 14-3 
Roofs
15)  One section of composition shingles were damaged. Leaks can occur as a result. This is a conducive condition for wood-destroying organisms. Recommend that a qualified contractor repair as necessary. For example, by replacing shingles.
Photo
Photo 15-1 
16)  Extensions such as splash blocks or drain pipes for one or more downspouts were missing. Water can accumulate around the building foundation or inside crawl spaces or basements as a result. Recommend that a qualified person install, replace or repair extensions as necessary so rainwater drains away from the structure.
Photo
Photo 16-1 
17)  Debris on the guest roof needs to be removed. There is a broom and dust pan on the roof.
Photo
Photo 17-1 
18)  Significant amounts of debris have accumulated in one or more gutters or downspouts. Gutters can overflow and cause water to come in contact with the building exterior, or water can accumulate around the foundation. This is a conducive condition for wood-destroying organisms. Recommend cleaning gutters and downspouts now and as necessary in the future.
Photo
Photo 18-1 
Photo
Photo 18-2 
19)  Section of the roof is abou a year old. the remaining roof is approximetly 10 to 15 years old.
Photo
Photo 19-1 
Photo
Photo 19-2 
Photo
Photo 19-3 
Photo
Photo 19-4 
Photo
Photo 19-5 
Photo
Photo 19-6 
Photo
Photo 19-7 
Photo
Photo 19-8 
Photo
Photo 19-9 
Photo
Photo 19-10 
Photo
Photo 19-11 
Photo
Photo 19-12 
Photo
Photo 19-13 
Photo
Photo 19-14 
Photo
Photo 19-15 
Photo
Photo 19-16 
Photo
Photo 19-17 
Photo
Photo 19-18 
Photo
Photo 19-19 
Photo
Photo 19-20 
Attics and Roof Structures
20)  What appeared to be vermiculite insulation was found in the attic. Vermiculite produced prior to 1991 may contain asbestos, less so if mined after 1991. When vermiculite insulation is present in attics, the EPA recommends that it be left undisturbed and that the attic not be used for storage, and that people (especially children) should not enter the attic. If the client is concerned about this material posing a safety hazard, then consult with a qualified asbestos abatement specialist or industrial hygienist. For more information, visit:
http://www.reporthost.com/?VERMINS
http://www.reporthost.com/?AITH
Photo
Photo 20-1 
Photo
Photo 20-2 
21)  One or more sections of the roof structure appeared to have substandard ventilation, soffit vents were missing and/or ridge vents were missing. This can result in high attic and roof surface temperatures, reduce the life of the roof covering materials, and/or increase cooling costs. High levels of moisture are also likely to accumulate in the roof structure or attic, and can be a conducive condition for wood-destroying organisms. Standard building practices require one free square foot of ventilation for every 150 square feet of attic space, and that vents be evenly distributed between the lowest points of the roof structure and the highest points to promote air circulation. Often this means that both soffit vents and ridge or gable end vents are installed. Recommend that a qualified contractor evaluate and repair per standard building practices.
22)  Garage loft - no attic access

Guest house - Attic access in the roof where the water heater is located. Possible signs of vermiculite in the attic.

Primary home - No signs of ventilation. Recommend looking into gable and attic fan to reduce attic temperature.
Photo
Photo 22-1 
Photo
Photo 22-2 
Photo
Photo 22-3 
Photo
Photo 22-4 
Photo
Photo 22-5 
Photo
Photo 22-6 
Photo
Photo 22-7 
Photo
Photo 22-8 
Photo
Photo 22-9 
Garages and Carports
23)  The automatic door opener at at unit(s) 2 was not plugged in. The inspector was unable to fully evaluate the automatic opener(s).

The middle garage door has the door opener unplugged. Home owner indicated that there may be an issue with the opener.
Photo
Photo 23-1 
24)  No issues with the interior of the garage.
Photo
Photo 24-1 
Photo
Photo 24-2 
Photo
Photo 24-3 
Electric
25)  One or more electric receptacles at the kitchen at unit(s) had no visible ground fault circuit interrupter (GFCI) protection, or the inspector was unable to determine if GFCI protection was present. If not GFCI-protected, receptacles in wet areas pose a shock hazard. Recommend that a qualified electrician evaluate and install GFCI protection if necessary and per standard building practices. General guidelines for GFCI-protected receptacles include the following locations:
  • Outdoors (since 1973)
  • Bathrooms (since 1975)
  • Garages (since 1978)
  • Kitchens (since 1987)
  • Crawl spaces and unfinished basements (since 1990)
  • Wet bar sinks (since 1993)
  • Laundry and utility sinks (since 2005)
For more information, visit:
http://www.reporthost.com/?GFCI

GFCI's missing in garage loft and guest house kitchens. Recommend having GFCI's installed to prevent a shock hazard.
Photo
Photo 25-1 
26)  One or more receptacles were broken or damaged at unit(s) 1. This is a potential shock or fire hazard. Recommend that a qualified electrician replace such receptacles as necessary.
Photo
Photo 26-1 
27)  Smoke alarms were missing from bedrooms at unit(s) 1. Smoke alarms should be installed as necessary so a functioning alarm exists in each hallway leading to bedrooms, in each bedroom and on each level. For more information, visit:
http://www.reporthost.com/?SMKALRM

https://tinyurl.com/smokecodetector
28)  One or more electric receptacles had reverse-polarity wiring, where the hot and neutral wires were reversed. This is a shock hazard.
Recommend that a qualified electrician repair as necessary. For more information, visit:
https://www.reporthost.com/?RPR

Primary residence - bathroom
Guest house - 2 outlets found.
Photo
Photo 28-1 
Photo
Photo 28-2 
Photo
Photo 28-3 
29)  Electric meters located on the exterior of each building.
Photo
Photo 29-1 
Photo
Photo 29-2 
Photo
Photo 29-3 
30)  Garage main panel - 200 amp circuit, no issues
Photo
Photo 30-1 
Photo
Photo 30-2 
Photo
Photo 30-3 
31)  Guest house - 200 amp panel - no issues
Photo
Photo 31-1 
Photo
Photo 31-2 
Photo
Photo 31-3 
32)  Primary house - 150 amp panel - no issues
Photo
Photo 32-1 
Photo
Photo 32-2 
Photo
Photo 32-3 
Plumbing / Fuel Systems
33)  Based on visible equipment or information provided to the inspector, this property appeared to have a yard irrigation (sprinkler) system. These are specialty systems and are excluded from this inspection. Comments in this report related to this system are made as a courtesy only and are not meant to be a substitute for a full evaluation by a qualified specialist. When this system is operated, recommend verifying that water is not directed at building exteriors, or directed so water accumulates around building foundations. Sprinkler heads may need to be adjusted, replaced or disabled. Consider having a qualified plumber verify that a backflow prevention device is installed per standard building practices to prevent cross-contamination of potable water. Recommend that a qualified specialist evaluate the irrigation system for other defects (e.g. leaks, damaged or malfunctioning sprinkler heads) and repair if necessary.
Photo
Photo 33-1 
34)  Based on visible components or information provided to the inspector, this property appeared to have a private sewage disposal (septic) system. These are specialty systems and are excluded from this inspection. Comments in this report related to this system are made as a courtesy only and are not meant to be a substitute for a full evaluation by a qualified specialist. Generally, septic tanks should be pumped and inspected every 3 years. Depending on the type of system and municipal regulations, inspection and maintenance may be required more frequently, often annually. Recommend the following:
  • Consult with the property owner about this system's maintenance and repair history
  • Review any documentation available for this system
  • Review inspection and maintenance requirements for this system
  • That a qualified specialist evaluate, perform maintenance and make repairs if necessary
For more information, visit:
http://www.reporthost.com/?SEPTIC
35)  Main water shutoff located in the basement
Photo
Photo 35-1 
36)  Gas meter located in the garage
Photo
Photo 36-1 
37)  Waste cleanout located in the basement, inside the guest home, and on the side of the garage.
Photo
Photo 37-1 
Photo
Photo 37-2 
Photo
Photo 37-3 
38)  Cesspool locations located in front of the guest house.
One for the primary home, the other for the quest and garage.
Photo
Photo 38-1 
Photo
Photo 38-2 
39)  Water pressure tested and found to be 55 psi.
Photo
Photo 39-1 
Water Heaters
40)  Garage - Water heater manufactured Jan. 2025
Water temp within specs
Photo
Photo 40-1 
Photo
Photo 40-2 
Photo
Photo 40-3 
41)  Guest house - water heater manufactured Sept. 2022
Water temp a little above recommended 120 degrees
Photo
Photo 41-1 
Photo
Photo 41-2 
Photo
Photo 41-3 
42)  primary - Gas water heater. Unable to find manufacturing date.
Water temp within specs.
Photo
Photo 42-1 
Photo
Photo 42-2 
Heating, Ventilation and Air Condition (HVAC)
43)  The outdoor air temperature was below 65 degrees Fahrenheit during the inspection. Air conditioning systems can be damaged if operated during such low temperatures. Because of this, the inspector was unable to operate and fully evaluate the cooling system(s).

Primary house AC manufactured in 2013 - 12 years old
Photo
Photo 43-1 
Photo
Photo 43-2 
Photo
Photo 43-3 
44)  Garage loft - no issues with heat. Hot air measured on all registers.
Photo
Photo 44-1 
Photo
Photo 44-2 
Photo
Photo 44-3 
Photo
Photo 44-4 
Photo
Photo 44-5 
Photo
Photo 44-6 
Photo
Photo 44-7 
Photo
Photo 44-8 
Photo
Photo 44-9 
Photo
Photo 44-10 
45)  Guest house - Manufactured in 2023 no issues heat measured out of all registers.
Photo
Photo 45-1 
Photo
Photo 45-2 
Photo
Photo 45-3 
Photo
Photo 45-4 
Photo
Photo 45-5 
Photo
Photo 45-6 
Photo
Photo 45-7 
Photo
Photo 45-8 
46)  Primary - no issues with furnace, manufactured in 2016.
Photo
Photo 46-1 
Photo
Photo 46-2 
Photo
Photo 46-3 
Photo
Photo 46-4 
Photo
Photo 46-5 
Photo
Photo 46-6 
Photo
Photo 46-7 
Photo
Photo 46-8 
Photo
Photo 46-9 
Photo
Photo 46-10 
Photo
Photo 46-11 
Photo
Photo 46-12 
Photo
Photo 46-13 
Photo
Photo 46-14 
Photo
Photo 46-15 
Photo
Photo 46-16 
Photo
Photo 46-17 
Photo
Photo 46-18 
Photo
Photo 46-19 
Photo
Photo 46-20 
Photo
Photo 46-21 
Photo
Photo 46-22 
Photo
Photo 46-23 Valve was turned off
Photo
Photo 46-24 Valve was turned off
Photo
Photo 46-25 
Photo
Photo 46-26 
Fireplaces, Stoves, Chimneys and Flues
47)  No issues with the gas fireplace.
Photo
Photo 47-1 
48)  No issues with any of chimneys in the primary or guest house.
Photo
Photo 48-1 
Photo
Photo 48-2 
Kitchen
49)  The oven bake function appeared to be inoperable at unit(s) 1. Consult with the property owner. If necessary, a qualified person should repair.

The right oven is not functioning and needs to be repaired.
Photo
Photo 49-1 
50)  The cooktop exhaust fan was inoperable at unit(s) 1. Recommend that a qualified person repair or replace as necessary.

Home owner indicated that it was turned off. Recommend that the exhaust fan be turned on and tested.
Photo
Photo 50-1 
Bathrooms, Laundry and Sinks
51)  A bathroom with a shower or bathtub didn't have an exhaust fan installed at unit(s) 1, 2 and/or 3. Moisture can accumulate and result in mold, bacteria or fungal growth. Even if the bathroom has a window that opens, it may not provide adequate ventilation, especially during cold weather when windows are closed or when wind blows air into the bathroom. Recommend that a qualified contractor install exhaust fans per standard building practices where missing in bathrooms with showers or bathtubs.
52)  The sink drain stopper mechanism was missing at unit(s) 1. Recommend that a qualified person repair or replace as necessary.

https://www.lowes.com/pd/Keeney-Chrome-Bathroom-Decorative-Sink-Drain/3133211
Photo
Photo 52-1 
53)  The bathtub drain stopper mechanism was inoperable at unit(s) 1 and/or 2. Recommend that a qualified person repair or replace as necessary.

Garage loft - Stopper and diverter is not functional. This does not allow you to take a bath, just a shower.
Primary - Rubber stopper has to be used.
https://www.lowes.com/search?searchTerm=bathtub+stoppert
Photo
Photo 53-1 Garage loft
Photo
Photo 53-2 Primary
Interiors, Doors and Windows
54)  One or more windows that were designed to open and close were stuck shut at unit(s) 1. Recommend that a qualified person repair windows as necessary so they open and close easily.
Photo
Photo 54-1 Kitchen window looks to be sticking on the top corner.
Wood Destroying Organism Findings
56)  Termite traps installed around structures. No signs of active or past issues
Photo
Photo 56-1 
Photo
Photo 56-2 
Photo
Photo 56-3 
Photo
Photo 56-4 
Photo
Photo 56-5 
Photo
Photo 56-6 
Swimming Pool
57)  One or more ground fault circuit interrupter (GFCI) electric circuit breakers and/or was missing . This is a safety hazard due to the risk of shock. A qualified electrician should evaluate and repair as necessary.

A GFCI (Ground Fault Circuit Interrupter) breaker should be installed in the main breaker that connects to a pool because it provides critical protection against electrical shock hazards. Since pools involve water, which is a strong conductor of electricity, the risk of accidental electrocution is significantly higher.
Here's why a GFCI breaker is essential:
- Shock Prevention: It detects even small leaks in electrical current and immediately shuts off power to prevent electrical shock.
- Code Compliance: Many local and national electrical codes require GFCI protection for pool equipment, such as pumps and lighting.
- Water Safety: Since water increases the likelihood of electrical faults, a GFCI breaker ensures that any unintended electrical current is cut off before it poses a danger.
- Equipment Protection: It helps prevent damage to pool equipment by stopping dangerous electrical faults early.
Photo
Photo 57-1 
58)  The swimming pool and its equipment were not fully evaluated because the pool was winterized. Recommend that a full evaluation be made by a qualified person when conditions have been corrected so the electricity supply is fully operable. Note that as per the standards of practice for InterNACHI (http://www.nachi.org) and ASHI (www.ashi.org), the inspector is not required to light pilot lights, operate overcurrent protection devices or operate any controls other than "normal controls".
Photo
Photo 58-1