This report published on Sunday, May 4, 2025 8:51:21 PM EDT
By relying on this inspection report you have agreed to be bound by the terms, conditions and limitations as set forth in the INSPECTION AGREEMENT, which has already been sent to you for review. If you did not receive an agreement for review, contact us immediately. In the event you do not agree to be bound by our INSPECTION AGREEMENT in its entirety, you must contact American League Inspection Services immediately upon receipt of this completed report. In addition, all electronic and paper copies of the inspection report must be deleted and destroyed and may not be used in whole or in part for consideration in a real estate transaction.
The inspection report is an unbiased assessment of the property for the day it was created. It is essential you read this report in its entirety and determine what you feel is important in regard to corrections needed. It is not intended to reflect the value of the property, or to make any representation as to the advisability of purchase. Not all improvements will be identified during this inspection. Unexpected repairs should still be anticipated. This inspection is not a guarantee or warranty of any kind.
American League Home Inspection Services performs all inspections in substantial compliance with the State of NY Standards. As such, we inspect the readily accessible, visually observable, installed systems and components of a home as designated. This Property Inspection Report contains observations of those systems and components that, in the professional judgment of the inspector, are not functioning properly, significantly defective, unsafe, or are near the end of their service lives. If the cause for the deficiency is not readily apparent, the suspected cause or reason why the system or component is at or near end of expected service life is reported, and recommendations for correction or monitoring are made as appropriate.
State standards define the scope of a home inspection. Clients sometimes assume that a home inspection will include many things that are beyond the scope. We encourage you to read the NY Standards of Practice so that you clearly understand what things are included in the home inspection and report.
Home Inspectors are generalists. Our position is to discover basic visible defects with the home and either suggest action or recommend further evaluation by a specialist in the appropriate field. In many cases generalists cannot diagnose conditions with major components or systems, due to the lack of specific licenses. Only individuals who carry the proper credentials can make proper assessments.
Any repairs or work suggested in this report should only be performed by qualified licensed individuals. We will not be responsible for any and all repairs made by sellers or unqualified individuals. While the inspector makes every effort to thoroughly inspect all aspects, so areas can be overlooked due to human error, or the event that areas are inaccessible. Some areas that are accessible can prohibit full view because objects or items that block or hinder full view of the space. Certain repairs may need to be performed, then an additional inspection may be needed to fully inspect an area.
The report has been prepared for your exclusive use, as our client. No use by third parties is intended. We will not be responsible to any parties for the contents of the report, other than the party named herein. The report itself is copyrighted and may not be used in whole or in part by any 3rd parties without the report owners express written permission.
Again, thanks very much for the opportunity of conducting this inspection for you. We are available to you throughout the entire real estate transaction process. Should you have any questions, please call or email us
How to Read this Report
This report is organized by the property's functional areas. Within each functional area, descriptive information is listed first and is shown in bold type. Items of concern follow descriptive information.
Concerns are shown and sorted according to these types:
Safety
Poses a safety hazard
Repair/Replace
Recommend repairing or replacing
Repair/Maintain
Recommend repair and/or maintenance
Minor Defect
Correction likely involves only a minor expense
Maintain
Recommend ongoing maintenance
Evaluate
Recommend evaluation by a specialist
Comment
For your information
Click here for a glossary of building construction terms.Contact your inspector If there are terms that you do not understand, or visit the glossary of construction terms at https://www.reporthost.com/glossary.asp
Limitations: Unless specifically included in the inspection, the following items and any related equipment, controls, electric systems and/or plumbing systems are excluded from this inspection: detached buildings or structures; fences and gates; retaining walls; underground drainage systems, catch basins or concealed sump pumps; swimming pools and related safety equipment, spas, hot tubs or saunas; whether deck, balcony and/or stair membranes are watertight; trees, landscaping, properties of soil, soil stability, erosion and erosion control; ponds, water features, irrigation or yard sprinkler systems; sport courts, playground, recreation or leisure equipment; areas below the exterior structures with less than 3 feet of vertical clearance; invisible fencing; sea walls, docks and boathouses; retractable awnings. Any comments made regarding these items are as a courtesy only.
Site profile: Level
Condition of driveways and parking areas: Appeared serviceable
Driveways and parking areas material: Asphalt
Condition of deck, patio and/or porch covers: Appeared serviceable
Deck, patio, porch cover material and type: Open
Condition of decks, porches and/or balconies: Appeared serviceable
Deck, porch and/or balcony material: Wood
Condition of stairs, handrails and guardrails: Appeared serviceable
Exterior stair material: Wood
1) Guardrails at one or more locations with drop-offs higher than 30 inches were deteriorated, and pose a fall hazard. Recommend that a qualified person repair guardrails as necessary.
Photo 1-1 Photo 1-2
2) Wood rot was found in decking boards at one or more decks or porches. Recommend that a qualified contractor evaluate and repair as necessary. All rotten wood should be replaced.
Recommend removing the loose paint by scraping or sanding and then paint to protect the wood from the elements.
Photo 2-1 Photo 2-2
Photo 2-3 Photo 2-4
Photo 2-5 Photo 2-6
Photo 2-7 Photo 2-8
Photo 2-9 Photo 2-10
Photo 2-11 Photo 2-12
Photo 2-13 Photo 2-14
Photo 2-15 Photo 2-16
Photo 2-17 Photo 2-18
3) Cracks, holes, settlement, heaving and/or deterioration were found in driveways and/or parking areas. Recommend that qualified contractor repair as necessary.
Photo 3-1 Photo 3-2
4) Recommend that the deck be prepped and painted to protect against the elements.
Photo 4-1 Photo 4-2
5) Minor deterioration (e.g. cracks, holes, settlement, heaving) was found in driveways and/or parking areas, but no trip hazards were found. The client may wish to have repairs made for cosmetic reasons.
Photo 5-1 Photo 5-2
6) Side panel by steps is rotted. Recommend replacing and protecting from the elements with several coats of a exterior paint or epoxy based paint.
Photo 6-1
7) majority of the asphalt is in a healthy condition.
Limitations: The inspector performs a visual inspection of accessible components or systems at the exterior. Items excluded from this inspection include below-grade foundation walls and footings; foundations, exterior surfaces or components obscured by vegetation, stored items or debris; wall structures obscured by coverings such as siding or trim. Some items such as siding, trim, soffits, vents and windows are often high off the ground, and may be viewed using binoculars from the ground or from a ladder. This may limit a full evaluation. Regarding foundations, some amount of cracking is normal in concrete slabs and foundation walls due to shrinkage and drying. Note that the inspector does not determine the adequacy of seismic reinforcement.
Condition of wall exterior covering: Appeared serviceable
Apparent wall structure: Wood frame
Wall covering: Wood, Metal
Condition of foundations and footings: Appeared serviceable
Apparent foundation types: Unfinished basement
Foundation/stem wall material: Poured in place concrete
Footing material (under foundation stem walls): Poured in place concrete
8) Some sections of siding and/or trim were damaged. Recommend that a qualified person repair, replace or install siding or trim as necessary.
Photo 8-1 Photo 8-2
Photo 8-3 Photo 8-4
Photo 8-5
9) Minor crack in the foundation. Recommend that this be repaired before winter. If water were to enter and freeze, it cause additional damage. https://tinyurl.com/dryloccaulk
Photo 9-1
10) Vegetation such as trees, shrubs and/or vines was in contact with or close to the building exterior. Vegetation can serve as a pathway for wood-destroying insects and can retain moisture against the exterior after it rains. This is a conducive condition for wood-destroying organisms. Recommend pruning, moving or removing vegetation as necessary to maintain at least 6 inches of space between it and the building exterior. A 1-foot clearance is better.
Photo 10-1 Photo 10-2
Photo 10-3 Photo 10-4
Photo 10-5 Photo 10-6
Photo 10-7 Photo 10-8
11) The paint or stain finish over much of the entire structure was failing (e.g. peeling, faded, worn, thinning). Siding and trim with a failing finish can be damaged by moisture. Recommend that a qualified contractor prep (e.g. clean, scrape, sand, prime, caulk) and repaint or restain the entire building exterior per standard building practices. Any repairs needed to the siding or trim should be made prior to this.
Photo 11-1 Photo 11-2
Photo 11-3 Photo 11-4
Photo 11-5 Photo 11-6
Photo 11-7 Photo 11-8
Photo 11-9 Photo 11-10
Photo 11-11
12) Cement pad on the side of the home is damaged and a section has been broken off. Recommend that the pad be repaired or replaced.
Limitations: Structural components such as joists and beams, and other components such as piping, wiring and/or ducting that are obscured by under-floor insulation are also excluded from this inspection. Note that the inspector does not determine if support posts, columns, beams, joists, studs, trusses, etc. are of adequate size, spanning or spacing.
The inspector does not guarantee or warrant that water will not accumulate in the basement in the future. Access to the basement during all seasons and during prolonged periods of all types of weather conditions (e.g. heavy rain, melting snow) would be needed to do so. The inspector does not determine the adequacy of basement floor or stairwell drains, or determine if such drains are clear or clogged.
Note that all basement areas should be checked periodically for water intrusion, plumbing leaks and pest activity.
Condition of exterior entry doors: Appeared serviceable
Exterior door material: Metal
Condition of floor substructure above: Appeared serviceable
Pier or support post material: Steel
Beam material: Steel
Floor structure above: Solid wood joists
Condition of insulation underneath floor above: Not applicable, none installed
Insulation material underneath floor above: None visible
13) Handrails at one or more flights of stairs were missing. This is a potential fall hazard. Handrails should be installed at stairs with four or more risers or where stairs are greater than 30 inches high. Recommend that a qualified contractor install handrails where missing and per standard building practices.
Photo 13-1
14) Spalling on cement walls, also known as concrete spalling, refers to the deterioration of the concrete surface where it flakes, chips, peels, or breaks away. This can happen due to various factors, including water damage, or freeze-thaw cycles.
No signs of elevated moisture levels at the time of the inspection.
Repairing Spalling:
Patching: Small spalls can often be repaired by patching with a suitable concrete repair material.
Resurfacing: For more extensive spalling, concrete resurfacing or overlaying can be used to restore the surface.
Professional Repair: In severe cases, professional repair may be necessary to address structural damage.
Limitations: The following items or areas are not included in this inspection: areas that could not be traversed or viewed clearly due to lack of access; solar roofing components. Any comments made regarding these items are made as a courtesy only. Note that the inspector does not provide an estimate of remaining life on the roof surface material, nor guarantee that leaks have not occurred in the roof surface, skylights or roof penetrations in the past. Regarding roof leaks, only active leaks, visible evidence of possible sources of leaks, and evidence of past leaks observed during the inspection are reported on as part of this inspection. The inspector does not guarantee or warrant that leaks will not occur in the future. Complete access to all roof and attic spaces during all seasons and during prolonged periods of all types of weather conditions (e.g. high wind and rain, melting snow) would be needed to do so. Occupants should monitor the condition of roofing materials in the future. For older roofs, recommend that a professional inspect the roof surface, flashings, appurtenances, etc. annually and maintain/repair as might be required. If needed, the roofer should enter attic space(s). Regarding the roof drainage system, unless the inspection was conducted during and after prolonged periods of heavy rain, the inspector was unable to determine if gutters, downspouts and extensions perform adequately or are leak-free.
Roof inspection method: Viewed from ground, Viewed from windows, Drone
Condition of roof surface material: Appeared serviceable
Roof surface material: Asphalt or fiberglass composition shingles, Synthetic plasticized or rubberized single-ply membrane
Roof type: Gable, Flat or low slope
Apparent number of layers of roof surface material: One
Condition of exposed flashings: Appeared serviceable
Condition of gutters, downspouts and extensions: Appeared serviceable
15) One section of composition shingles were damaged. Leaks can occur as a result. This is a conducive condition for wood-destroying organisms. Recommend that a qualified contractor repair as necessary. For example, by replacing shingles.
Photo 15-1
16) Extensions such as splash blocks or drain pipes for one or more downspouts were missing. Water can accumulate around the building foundation or inside crawl spaces or basements as a result. Recommend that a qualified person install, replace or repair extensions as necessary so rainwater drains away from the structure.
Photo 16-1
17) Debris on the guest roof needs to be removed. There is a broom and dust pan on the roof.
Photo 17-1
18) Significant amounts of debris have accumulated in one or more gutters or downspouts. Gutters can overflow and cause water to come in contact with the building exterior, or water can accumulate around the foundation. This is a conducive condition for wood-destroying organisms. Recommend cleaning gutters and downspouts now and as necessary in the future.
Photo 18-1 Photo 18-2
19) Section of the roof is abou a year old. the remaining roof is approximetly 10 to 15 years old.
Limitations: The following items or areas are not included in this inspection: areas that could not be traversed or viewed clearly due to lack of access; areas and components obscured by insulation. Any comments made regarding these items are made as a courtesy only. The inspector does not determine the adequacy of the attic ventilation system. Complete access to all roof and attic spaces during all seasons and during prolonged periods of all types of weather conditions (e.g. high/low temperatures, high/low humidity, high wind and rain, melting snow) would be needed to do so. The inspector is not a licensed engineer and does not determine the adequacy of roof structure components such as trusses, rafters or ceiling beams, or their spacing or sizing.
Attic inspection method: Partially traversed
Condition of roof structure: Appeared serviceable
Roof structure type: Rafters
Ceiling structure: Ceiling joists, Ceiling beams
Condition of insulation in attic (ceiling, skylight chase, etc.): Appeared serviceable
Ceiling insulation material: Fiberglass roll or batt, Vermiculite loose fill
Approximate attic insulation R value (may vary in areas): R-30
Vapor retarder: None visible
Condition of roof ventilation: none visible
20) What appeared to be vermiculite insulation was found in the attic. Vermiculite produced prior to 1991 may contain asbestos, less so if mined after 1991. When vermiculite insulation is present in attics, the EPA recommends that it be left undisturbed and that the attic not be used for storage, and that people (especially children) should not enter the attic. If the client is concerned about this material posing a safety hazard, then consult with a qualified asbestos abatement specialist or industrial hygienist. For more information, visit: http://www.reporthost.com/?VERMINS http://www.reporthost.com/?AITH
Photo 20-1 Photo 20-2
21) One or more sections of the roof structure appeared to have substandard ventilation, soffit vents were missing and/or ridge vents were missing. This can result in high attic and roof surface temperatures, reduce the life of the roof covering materials, and/or increase cooling costs. High levels of moisture are also likely to accumulate in the roof structure or attic, and can be a conducive condition for wood-destroying organisms. Standard building practices require one free square foot of ventilation for every 150 square feet of attic space, and that vents be evenly distributed between the lowest points of the roof structure and the highest points to promote air circulation. Often this means that both soffit vents and ridge or gable end vents are installed. Recommend that a qualified contractor evaluate and repair per standard building practices.
22) Garage loft - no attic access
Guest house - Attic access in the roof where the water heater is located. Possible signs of vermiculite in the attic.
Primary home - No signs of ventilation. Recommend looking into gable and attic fan to reduce attic temperature.
Limitations: The inspector cannot reasonably determine the integrity of all elements of limited fire resistance at residential construction or verify firewall ratings at multi unit construction. Requirements for ventilation in garages vary between municipalities.
Condition of garage vehicle doors: Appeared serviceable
Types of garage vehicle doors: Sectional
Condition of automatic openers: Appeared serviceable, Not determined (not plugged in, no power, etc.)
Mechanical auto-reverses operable (reverses when meeting reasonable resistance during closing): Yes
Condition of garage interiors: Appeared serviceable
Ventilation in garages: None visible
23) The automatic door opener at at unit(s) 2 was not plugged in. The inspector was unable to fully evaluate the automatic opener(s).
The middle garage door has the door opener unplugged. Home owner indicated that there may be an issue with the opener.
Limitations: The following items are not included in this inspection: generator systems, transfer switches, surge suppressors, inaccessible or concealed wiring; underground utilities and systems; low-voltage lighting or lighting on timers or sensors. Any comments made regarding these items are as a courtesy only. Note that the inspector does not determine the adequacy of grounding or bonding, if this system has an adequate capacity for the client's specific or anticipated needs, or if this system has any reserve capacity for additions or expansion. The inspector does not operate circuit breakers as part of the inspection, and does not install or change light bulbs. The inspector does not evaluate every wall switch or receptacle, but instead tests a representative number of them per various standards of practice. When furnishings, stored items or child-protective caps are present some receptacles are usually inaccessible and are not tested; these are excluded from this inspection. Receptacles that are not of standard 110 volt configuration, including 240-volt dryer receptacles, are not tested and are excluded. The functionality of, power source for and placement of smoke and carbon monoxide alarms is not determined as part of this inspection. Upon taking occupancy, proper operating and placement of smoke and carbon monoxide alarms should be verified and batteries should be changed. These devices have a limited lifespan and should be replaced every 10 years. The inspector attempts to locate and evaluate all main and sub-panels. However, panels are often concealed. If panels are found after the inspection, a qualified electrician should evaluate and repair if necessary. The inspector attempts to determine the overall electrical service size, but such estimates are not guaranteed because the overall capacity may be diminished by lesser-rated components in the system. Any repairs recommended should be made by a licensed electrician.
Electric service condition: Appeared serviceable
Primary service type: Overhead
Typical number of service conductors: 2
Typical service voltage (volts): 120-240
Typical estimated service amperage: 150, 200
Typical primary service overload protection type: Circuit breakers
Typical service entrance conductor material: Stranded copper
Typical main disconnect rating (amps): 150, 200
Typical system ground: Cold water supply pipes
Condition of main service panel(s): Appeared serviceable
Typical location of main disconnect(s): At main service panels in each unit
Carbon monoxide alarms installed: Yes, but not tested
25) One or more electric receptacles at the kitchen at unit(s) had no visible ground fault circuit interrupter (GFCI) protection, or the inspector was unable to determine if GFCI protection was present. If not GFCI-protected, receptacles in wet areas pose a shock hazard. Recommend that a qualified electrician evaluate and install GFCI protection if necessary and per standard building practices. General guidelines for GFCI-protected receptacles include the following locations:
Outdoors (since 1973)
Bathrooms (since 1975)
Garages (since 1978)
Kitchens (since 1987)
Crawl spaces and unfinished basements (since 1990)
GFCI's missing in garage loft and guest house kitchens. Recommend having GFCI's installed to prevent a shock hazard.
Photo 25-1
26) One or more receptacles were broken or damaged at unit(s) 1. This is a potential shock or fire hazard. Recommend that a qualified electrician replace such receptacles as necessary.
Photo 26-1
27) Smoke alarms were missing from bedrooms at unit(s) 1. Smoke alarms should be installed as necessary so a functioning alarm exists in each hallway leading to bedrooms, in each bedroom and on each level. For more information, visit: http://www.reporthost.com/?SMKALRM
28) One or more electric receptacles had reverse-polarity wiring, where the hot and neutral wires were reversed. This is a shock hazard. Recommend that a qualified electrician repair as necessary. For more information, visit: https://www.reporthost.com/?RPR
Primary residence - bathroom Guest house - 2 outlets found.
Photo 28-1 Photo 28-2
Photo 28-3
29) Electric meters located on the exterior of each building.
Photo 29-1 Photo 29-2
Photo 29-3
30) Garage main panel - 200 amp circuit, no issues
Limitations: The following items are not included in this inspection: private/shared wells and related equipment; private sewage disposal systems; hot tubs or spas; main, side and lateral sewer lines; gray water systems; pressure boosting systems; trap primers; incinerating or composting toilets; fire suppression systems; water softeners, conditioners or filtering systems; plumbing components concealed within the foundation or building structure, or in inaccessible areas such as below tubs; underground utilities and systems; overflow drains for tubs and sinks; backflow prevention devices. Any comments made regarding these items are as a courtesy only. Note that the inspector does not operate water supply or shut-off valves due to the possibility of valves leaking or breaking when operated. The inspector does not test for lead in the water supply, the water pipes or solder, does not determine if plumbing and fuel lines are adequately sized, and does not determine the existence or condition of underground or above-ground fuel tanks.
Condition of service and main line: Appeared serviceable
Water service: Public
Typical water pressure (psi): 55 psi
Typical location of main water shut-off(s): Basement
Condition of supply lines: Appeared serviceable
Typical supply pipe material: Copper
Condition of drain pipes: Appeared serviceable
Drain pipe material: Plastic, Metal
Condition of waste lines: Appeared serviceable
Waste pipe material: Cast iron
Vent pipe condition: Appeared serviceable
Vent pipe material: Plastic, Cast iron
Condition of fuel system: Appeared serviceable
Location of main fuel shut-off valve(s): At gas meter(s)
33) Based on visible equipment or information provided to the inspector, this property appeared to have a yard irrigation (sprinkler) system. These are specialty systems and are excluded from this inspection. Comments in this report related to this system are made as a courtesy only and are not meant to be a substitute for a full evaluation by a qualified specialist. When this system is operated, recommend verifying that water is not directed at building exteriors, or directed so water accumulates around building foundations. Sprinkler heads may need to be adjusted, replaced or disabled. Consider having a qualified plumber verify that a backflow prevention device is installed per standard building practices to prevent cross-contamination of potable water. Recommend that a qualified specialist evaluate the irrigation system for other defects (e.g. leaks, damaged or malfunctioning sprinkler heads) and repair if necessary.
Photo 33-1
34) Based on visible components or information provided to the inspector, this property appeared to have a private sewage disposal (septic) system. These are specialty systems and are excluded from this inspection. Comments in this report related to this system are made as a courtesy only and are not meant to be a substitute for a full evaluation by a qualified specialist. Generally, septic tanks should be pumped and inspected every 3 years. Depending on the type of system and municipal regulations, inspection and maintenance may be required more frequently, often annually. Recommend the following:
Consult with the property owner about this system's maintenance and repair history
Review any documentation available for this system
Review inspection and maintenance requirements for this system
That a qualified specialist evaluate, perform maintenance and make repairs if necessary
Limitations: Evaluation of and determining the adequacy or completeness of the following items are not included in this inspection: water recirculation pumps; solar water heating systems; Energy Smart or energy saver controls; catch pan drains. Any comments made regarding these items are as a courtesy only. Note that the inspector does not provide an estimate of remaining life on water heaters, does not determine if water heaters are appropriately sized, or perform any evaluations that require a pilot light to be lit or a shut-off valve to be operated.
Condition of water heaters: Appeared serviceable
Types: Tank
Energy sources: Electricity, Natural gas
Condition of burners: Appeared serviceable
Condition of venting systems: Appeared serviceable
Condition of combustion air supplies: Appeared serviceable
40) Garage - Water heater manufactured Jan. 2025 Water temp within specs
Photo 40-1 Photo 40-2
Photo 40-3
41) Guest house - water heater manufactured Sept. 2022 Water temp a little above recommended 120 degrees
Photo 41-1 Photo 41-2
Photo 41-3
42) primary - Gas water heater. Unable to find manufacturing date. Water temp within specs.
Limitations: The following items are not included in this inspection: humidifiers, dehumidifiers, electronic air filters; solar, coal or wood-fired heat systems; thermostat or temperature control accuracy and timed functions; heating components concealed within the building structure or in inaccessible areas; underground utilities and systems; safety devices and controls (due to automatic operation). Any comments made regarding these items are as a courtesy only. Note that the inspector does not provide an estimate of remaining life on heating or cooling system components, does not determine if heating or cooling systems are appropriately sized, does not test coolant pressure, or perform any evaluations that require a pilot light to be lit, a shut-off valve to be operated, a circuit breaker to be turned "on" or a serviceman's or oil emergency switch to be operated. It is beyond the scope of this inspection to determine if furnace heat exchangers are intact and free of leaks. Condensation pans and drain lines may clog or leak at any time and should be monitored while in operation in the future. Where buildings contain furnishings or stored items, the inspector may not be able to verify that a heat source is present in all "liveable" rooms (e.g. bedrooms, kitchens and living/dining rooms).
Heating system type(s): Forced air, Radiant
Heating distribution type(s): Ducts and registers, Pipes and radiators
Condition of forced air heating/(cooling) system: Appeared serviceable
Forced air heating system fuel types: Electric
Condition of furnace filters: Appeared serviceable
Condition of forced air ducts and registers: Appeared serviceable
Condition of hydronic or steam heat system: Appeared serviceable
Type of hydronic or steam heat: Steam
Hydronic or steam heat fuel type: Natural gas
Condition of cooling system and/or heat pump: Appeared serviceable
Cooling system and/or heat pump fuel type: Electric
Type: Split system
Condition of controls: Appeared serviceable
43) The outdoor air temperature was below 65 degrees Fahrenheit during the inspection. Air conditioning systems can be damaged if operated during such low temperatures. Because of this, the inspector was unable to operate and fully evaluate the cooling system(s).
Primary house AC manufactured in 2013 - 12 years old
Photo 43-1 Photo 43-2
Photo 43-3
44) Garage loft - no issues with heat. Hot air measured on all registers.
Photo 44-1 Photo 44-2
Photo 44-3 Photo 44-4
Photo 44-5 Photo 44-6
Photo 44-7 Photo 44-8
Photo 44-9 Photo 44-10
45) Guest house - Manufactured in 2023 no issues heat measured out of all registers.
Photo 45-1 Photo 45-2
Photo 45-3 Photo 45-4
Photo 45-5 Photo 45-6
Photo 45-7 Photo 45-8
46) Primary - no issues with furnace, manufactured in 2016.
Photo 46-1 Photo 46-2
Photo 46-3 Photo 46-4
Photo 46-5 Photo 46-6
Photo 46-7 Photo 46-8
Photo 46-9 Photo 46-10
Photo 46-11 Photo 46-12
Photo 46-13 Photo 46-14
Photo 46-15 Photo 46-16
Photo 46-17 Photo 46-18
Photo 46-19 Photo 46-20
Photo 46-21 Photo 46-22
Photo 46-23 Valve was turned off Photo 46-24 Valve was turned off
Limitations: The following items are not included in this inspection: coal stoves, gas logs, chimney flues (except where visible). Any comments made regarding these items are as a courtesy only. Note that the inspector does not determine the adequacy of drafting or sizing in fireplace and stove flues, and also does not determine if prefabricated or zero-clearance fireplaces are installed in accordance with the manufacturer's specifications. The inspector does not perform any evaluations that require a pilot light to be lit, and does not light fires. The inspector provides a basic visual examination of a chimney and any associated wood burning device. The National Fire Protection Association has stated that an in-depth Level 2 chimney inspection should be part of every sale or transfer of property with a wood-burning device. Such an inspection may reveal defects that are not apparent to the home inspector who is a generalist.
Condition of gas-fired fireplaces or stoves: Appeared serviceable
Gas fireplace or stove types: Converted wood-burning fireplace
Condition of chimneys and flues: Appeared serviceable
47) No issues with the gas fireplace.
Photo 47-1
48) No issues with any of chimneys in the primary or guest house.
Limitations: The following items are not included in this inspection: household appliances such as stoves, ovens, cook tops, ranges, warming ovens, griddles, broilers, dishwashers, trash compactors, refrigerators, freezers, ice makers, hot water dispensers and water filters; appliance timers, clocks, cook functions, self and/or continuous cleaning operations, thermostat or temperature control accuracy, and lights. Any comments made regarding these items are as a courtesy only. Note that the inspector does not provide an estimate of the remaining life of appliances, and does not determine the adequacy of operation of appliances. The inspector does not note appliance manufacturers, models or serial numbers and does not determine if appliances are subject to recalls. Areas and components behind and obscured by appliances are inaccessible and excluded from this inspection.
Condition of counters: Appeared serviceable
Condition of cabinets: Appeared serviceable
Condition of sinks and related plumbing: Appeared serviceable
Condition of under-sink food disposals: N/A (none installed)
Condition of dishwasher: Appeared serviceable
Condition of ranges, cooktops and/or ovens: Appeared serviceable, Required repair, replacement and/or evaluation (see comments below)
Range, cooktop, oven type: Natural gas, Electric
Condition of refrigerators: Appeared serviceable
Condition of built-in microwave ovens: N/A (none installed)
Condition of hot water dispensers: N/A (none installed)
Condition of trash compactors: N/A (none installed)
49) The oven bake function appeared to be inoperable at unit(s) 1. Consult with the property owner. If necessary, a qualified person should repair.
The right oven is not functioning and needs to be repaired.
Photo 49-1
50) The cooktop exhaust fan was inoperable at unit(s) 1. Recommend that a qualified person repair or replace as necessary.
Home owner indicated that it was turned off. Recommend that the exhaust fan be turned on and tested.
Limitations: The following items are not included in this inspection: overflow drains for tubs and sinks; heated towel racks, saunas, steam generators, clothes washers, clothes dryers. Any comments made regarding these items are as a courtesy only. Note that the inspector does not determine the adequacy of washing machine drain lines, washing machine catch pan drain lines, or clothes dryer exhaust ducts. The inspector does not operate water supply or shut-off valves for sinks, toilets, bidets, clothes washers, etc. due to the possibility of valves leaking or breaking when operated. The inspector does not determine if shower pans or tub and shower enclosures are water tight, or determine the completeness or operability of any gas piping to laundry appliances.
Condition of counters: Appeared serviceable
Condition of cabinets: Appeared serviceable
Condition of flooring: Appeared serviceable
Condition of sinks and related plumbing: Appeared serviceable
Condition of bathtubs and related plumbing: Appeared serviceable
Condition of shower(s) and related plumbing: Appeared serviceable
Condition of ventilation systems: Appeared serviceable
51) A bathroom with a shower or bathtub didn't have an exhaust fan installed at unit(s) 1, 2 and/or 3. Moisture can accumulate and result in mold, bacteria or fungal growth. Even if the bathroom has a window that opens, it may not provide adequate ventilation, especially during cold weather when windows are closed or when wind blows air into the bathroom. Recommend that a qualified contractor install exhaust fans per standard building practices where missing in bathrooms with showers or bathtubs.
52) The sink drain stopper mechanism was missing at unit(s) 1. Recommend that a qualified person repair or replace as necessary.
Limitations: The following items are not included in this inspection: security, intercom and sound systems; communications wiring; central vacuum systems; elevators and stair lifts; cosmetic deficiencies such as nail-pops, scuff marks, dents, dings, blemishes or issues due to normal wear and tear in wall, floor and ceiling surfaces and coverings, or in equipment; deficiencies relating to interior decorating; low voltage and gas lighting systems. Any comments made regarding these items are as a courtesy only. Note that the inspector does not evaluate any areas or items which require moving stored items, furnishings, debris, equipment, floor coverings, insulation or similar materials. The inspector does not test for asbestos, lead, radon, mold, hazardous waste, urea formaldehyde urethane, or any other toxic substance. Some items such as window, drawer, cabinet door or closet door operability are tested on a sampled basis. The client should be aware that paint may obscure wall and ceiling defects, floor coverings may obscure floor defects, and furnishings may obscure wall, floor and floor covering defects. If furnishings were present during the inspection, recommend a full evaluation of walls, floors and ceilings that were previously obscured when possible. Carpeting and flooring, when installed over concrete slabs, may conceal moisture. If dampness wicks through a slab and is hidden by floor coverings that moisture can result in unhygienic conditions, odors or problems that will only be discovered when/if the flooring is removed. Determining the cause and/or source of odors is not within the scope of this inspection.
Condition of exterior entry doors: Appeared serviceable
Exterior door material: Wood, Glass panel
Condition of interior doors: Appeared serviceable
Condition of windows and skylights: Appeared serviceable
Condition of walls and ceilings: Appeared serviceable
Wall type or covering: Drywall or plaster
Ceiling type or covering: Drywall or plaster
Condition of flooring: Appeared serviceable
Condition of concrete slab floor(s): Appeared serviceable
Flooring type or covering: Carpet, Vinyl, linoleum or marmoleum, Wood or wood products, Tile
Condition of stairs, handrails and guardrails: Appeared serviceable
54) One or more windows that were designed to open and close were stuck shut at unit(s) 1. Recommend that a qualified person repair windows as necessary so they open and close easily.
Photo 54-1 Kitchen window looks to be sticking on the top corner.
Limitations: This report only includes findings from accessible and visible areas on the day of the inspection. In addition to the inaccessible areas documented in this report, examples of other inaccessible areas include: sub areas less than 18 inches in height; attic areas less than 5 feet in height, areas blocked by ducts, pipes or insulation; areas where locks or permanently attached covers prevent access; areas where insulation would be damaged if traversed; areas obscured by vegetation. All inaccessible areas are subject to infestation or damage from wood-destroying organisms. The inspector does not move furnishings, stored items, debris, floor or wall coverings, insulation, or other materials as part of the inspection, nor perform destructive testing. Wood-destroying organisms may infest, re-infest or become active at any time. No warranty is provided as part of this inspection.
Visible evidence of active wood-destroying insects: No
Visible evidence of active wood decay fungi: No
Visible evidence of past wood-destroying insects: No
Visible evidence of past wood decay fungi: No
Visible evidence of damage by wood-destroying insects: No
Visible evidence of damage by wood decay fungi: No
Visible evidence of conditions conducive to wood-destroying organisms: No
56) Termite traps installed around structures. No signs of active or past issues
Limitations: The following items are not included in this inspection: swimming pool bodies; equipment on timers, remote controls or sensors; underground or concealed piping; motorized covers; waterfalls and related equipment; Ozone generators; ultraviolet light systems; filter backflushing mechanisms. Any comments made regarding these items are as a courtesy only. Note that the inspector does not disassemble filters, remove pool covers, nor determine if swimming pool bodies, filters or skimmers leak, nor determine if swimming pool bodies are level.
Water level: Low
57) One or more ground fault circuit interrupter (GFCI) electric circuit breakers and/or was missing . This is a safety hazard due to the risk of shock. A qualified electrician should evaluate and repair as necessary.
A GFCI (Ground Fault Circuit Interrupter) breaker should be installed in the main breaker that connects to a pool because it provides critical protection against electrical shock hazards. Since pools involve water, which is a strong conductor of electricity, the risk of accidental electrocution is significantly higher. Here's why a GFCI breaker is essential: - Shock Prevention: It detects even small leaks in electrical current and immediately shuts off power to prevent electrical shock. - Code Compliance: Many local and national electrical codes require GFCI protection for pool equipment, such as pumps and lighting. - Water Safety: Since water increases the likelihood of electrical faults, a GFCI breaker ensures that any unintended electrical current is cut off before it poses a danger. - Equipment Protection: It helps prevent damage to pool equipment by stopping dangerous electrical faults early.
Photo 57-1
58) The swimming pool and its equipment were not fully evaluated because the pool was winterized. Recommend that a full evaluation be made by a qualified person when conditions have been corrected so the electricity supply is fully operable. Note that as per the standards of practice for InterNACHI (http://www.nachi.org) and ASHI (www.ashi.org), the inspector is not required to light pilot lights, operate overcurrent protection devices or operate any controls other than "normal controls".
Photo 58-1
Thank You for your business. Any questions - please contact American League Home Inspection at ALHInspection.com