JM CONSULTANT AND SERVICES LLC

1623 Grandview Ave 
Braddock PA 15104-3009
Inspector: James Mack
Inspector's email: jmack0788@gmail.com
Inspector's phone: (412) 676-9927

Practice Property Inspection Report 1

Client(s):  Rosalie and James mack
Property address:  1623 Grandview Ave
Braddock PA 15104-3009
Inspection date:  Monday, June 24, 2024

This report published on Tuesday, July 16, 2024 11:06:08 AM EDT

This report has been prepared for the sole and exclusive use of the client indicated above and is limited to an impartial opinion which is not a warranty that the items inspected are defect-free. or the latent or concealed defects may exist as of the date of the inspection or which may have existed in the past or may exist in the future. The report is limited to the components of the property which were visible to the inspector on the date of the inspection and his opinion of their condition at the time of the inspection.

How to Read this Report
This report is organized by the property's functional areas.  Within each functional area, descriptive information is listed first and is shown in bold type.  Items of concern follow descriptive information. Concerns are shown and sorted according to these types:
Concern typeSafetyPoses a safety hazard
Concern typeMajor DefectCorrection likely involves a significant expense
Concern typeRepair/ReplaceRecommend repairing or replacing
Concern typeRepair/MaintainRecommend repair and/or maintenance
Concern typeMaintainRecommend ongoing maintenance
Concern typeEvaluateRecommend evaluation by a specialist
Concern typeMonitorRecommend monitoring in the future
Concern typeServiceableItem or component is in serviceable condition
Concern typeCommentFor your information

Click here for a glossary of building construction terms.Contact your inspector If there are terms that you do not understand, or visit the glossary of construction terms at https://www.reporthost.com/glossary.asp

Table of Contents

General Information
Standards Of Practice
Grounds
Exterior and Foundation
Basements & crawl spaces
Roof, Attic and Roof Structure
Electric
Hvac, Water Heater, and Chimneys
Kitchen
Plumbing and Bathrooms
Interior, Doors and Windows
Wood Destroying Organism Findings

View summary

General Information
Table of contents
Report number: 62424-01
Present during inspection: Tenant
Weather conditions during inspection: Dry (no rain)
Temperature during inspection: Hot
Inspection fee: 0
Payment method:
Type of building: Single family
Buildings inspected: One house
Number of residential units inspected: 1
Age of main building: 104
Source for main building age: Client
Occupied: Yes
1) Structures built prior to the mid 1980s may contain lead and/or asbestos. Lead is commonly found in paint and in some plumbing components. The EPA does not recognize newer coats of paint as encapsulating older coats of lead-based paint. Asbestos is commonly found in various building materials such as insulation, siding, and/or floor and ceiling tiles. Laws were passed in 1978 to prohibit usage of lead and asbestos, but stocks of materials containing these substances remained in use for a number of years thereafter. Both lead and asbestos are known health hazards. Evaluating for the presence of lead and/or asbestos is beyond the scope of this inspection. Any mention of these materials in this report is made as a courtesy only, and meant to refer the client to a specialist. Consult with specialists as necessary, such as industrial hygienists, professional labs and/or abatement specialists for this type of evaluation. For information on lead, asbestos and other hazardous materials in homes, visit:
https://www.reporthost.com/?EPA
https://www.reporthost.com/?CPSC
https://www.reporthost.com/?CDC
Standards Of Practice
Table of contents
Limitations: Unless specifically included in the inspection, the following items and any related equipment, controls, electric systems and/or plumbing systems are excluded from this inspection: detached buildings or structures; fences and gates; retaining walls; underground drainage systems, catch basins or concealed sump pumps; swimming pools and related safety equipment, spas, hot tubs or saunas; whether deck, balcony and/or stair membranes are watertight; trees, landscaping, properties of soil, soil stability, erosion and erosion control; ponds, water features, irrigation or yard sprinkler systems; sport courts, playground, recreation or leisure equipment; areas below the exterior structures with less than 3 feet of vertical clearance; invisible fencing; sea walls, docks and boathouses; retractable awnings. Any comments made regarding these items are as a courtesy only.
Site profile: Level
Condition of sidewalks and/or patios: Required repairs, replacement and/or evaluation (see comments below)
Sidewalk material: Poured in place concrete
Condition of deck, patio and/or porch covers: Appeared serviceable
Deck, patio, porch cover material and type: Covered (Refer to Roof section)
Condition of decks, porches and/or balconies: Appeared serviceable
Deck, porch and/or balcony material: Wood
Condition of stairs, handrails and guardrails: Required repairs, replacement and/or evaluation (see comments below)
Exterior stair material: Concrete
3) Handrails missing. This is a fall hazard. Recommend a reputable contractor.
Photo
Photo 3-1 No hand rails are weatherstripping for crawl space access
4) Walkway appear to be deteriorating. This is a trip hazard. Recommend a reputable contractor.
Photo
Photo 4-1 Walk way on right side of house slope toward property
5) Concrete walkway is Heaving. This is a trip hazard. Recommend a reputable contractor.
Photo
Photo 5-1 Back entrance has Uneven walking path
6) Settlement cracks and missing handrails and balusters. This is a fall hazard. Recommend a reputable contractor.
Photo
Photo 6-1 Front steps
7) Front step Handrail is lose and missing appropriate 4" balusters. This will allow for injury are worst. This is a fall hazard. Recommend a reputable contractor
Photo
Photo 7-1 Front entrance Wobbly rail
Exterior and Foundation
Table of contents
Wall inspection method: Viewed from ground
Condition of wall exterior covering: Required repairs, replacement and/or evaluation (see comments below)
Apparent wall structure: Wood frame, Stone
Wall covering: Vinyl
Condition of foundation and footings: Appeared serviceable
Apparent foundation type: Unfinished basement
Foundation/stem wall material: Stone
Footing material (under foundation stem wall): Stone
8) Siding on left side of the house in one are more section of siding was lose are missing on of house. This will allow for water and pest infestation. Recommend a reputable contractor.
Photo
Photo 8-1 Left side of home lose and missing sidin
9) Their are Settlement cracks on front foundation wall. Their is spray insulation used instead of concrete. Recommend filling in with concrete caulking. Continue to monitor.
Photo
Photo 9-1 Settlement cracks
Photo
Photo 9-2 Settlement cracks
Photo
Photo 9-3 Settlement cracks
Photo
Photo 9-4 Settlement cracks
10) There is an overgrown bush on left side of house. This will allow for pest infestation. Recommend trimming back 2 to 3 feet.
Photo
Photo 10-1 vegetation to close to house
Basements & crawl spaces
Table of contents
Limitations: Structural components such as joists and beams, and other components such as piping, wiring and/or ducting that are obscured by under-floor insulation are also excluded from this inspection. Note that the inspector does not determine if support posts, columns, beams, joists, studs, trusses, etc. are of adequate size, spanning or spacing.

The inspector does not guarantee or warrant that water will not accumulate in the basement in the future. Access to the basement during all seasons and during prolonged periods of all types of weather conditions (e.g. heavy rain, melting snow) would be needed to do so. The inspector does not determine the adequacy of basement floor or stairwell drains, or determine if such drains are clear or clogged.

Note that all basement areas should be checked periodically for water intrusion, plumbing leaks and pest activity.
Limitations: Structural components such as joists and beams, and other components such as piping, wiring and/or ducting that are obscured by under-floor insulation are excluded from this inspection. The inspector does not determine if support posts, columns, beams, joists, studs, trusses, etc. are of adequate size, spanning or spacing.

The inspector does not guarantee or warrant that water will not accumulate in the crawl spaces in the future. Complete access to all crawl space areas during all seasons and during prolonged periods of all types of weather conditions (e.g. heavy rain, melting snow) would be needed to do so.

The inspector attempts to locate all crawl space access points and areas. Access points may be obscured or otherwise hidden by furnishings or stored items. In such cases, the client should ask the property owner where all access points are that are not described in this inspection, and have those areas inspected. Note that crawl space areas should be checked at least annually for water intrusion, plumbing leaks and pest activity.
Condition of exterior entry doors: Required repair, replacement and/or evaluation (see comments below)
Crawl space inspection method: Traversed
Exterior door material: Wood
Condition of floor substructure above: Appeared serviceable
Pier or support post material: Wood, Steel
Beam material: Built-up wood, Steel
Floor structure above: Solid wood joists
Floor structure above: Engineered wood joists
Condition of insulation underneath floor above: Not applicable, none installed
Insulation material underneath floor above: None visible
Condition of vapor barrier: Not determined (inaccessible or obscured)
Vapor barrier present: None visible
11) Outdoor crawl space access hatch missing locks and weatherstripping. Water and/or vermin can enter the basement and foundation space. Recommend a reputable contractor.
Photo
Photo 11-1 No hand rails are weatherstripping for crawl space access
Photo
Photo 11-2 
12) One or more adjustable steel columns were found and not anchored to floor. Some adjustable steel columns are rated for permanent use. Recommend a reputable contractor.
Photo
Photo 12-1 
13) Missing Handrail and balusters leading to basement. This is a fall hazard. Recommend a reputable contractor.
Photo
Photo 13-1 No hand rail leading to basement
14) Efflorescence(mineral salts).Their probable mold on all foundations walls. Recommend a reputable certified mold tester. Recommend a reputable waterproofing contractor.
Photo
Photo 14-1 Efflorescence
Photo
Photo 14-2 Efflorescence
Photo
Photo 14-3 Probable mold
Roof, Attic and Roof Structure
Table of contents
Limitations: The following items or areas are not included in this inspection: areas that could not be traversed or viewed clearly due to lack of access; areas and components obscured by insulation. Any comments made regarding these items are made as a courtesy only. The inspector does not determine the adequacy of the attic ventilation system. Complete access to all roof and attic spaces during all seasons and during prolonged periods of all types of weather conditions (e.g. high/low temperatures, high/low humidity, high wind and rain, melting snow) would be needed to do so. The inspector is not a licensed engineer and does not determine the adequacy of roof structure components such as trusses, rafters or ceiling beams, or their spacing or sizing.
Limitations: The following items or areas are not included in this inspection: areas that could not be traversed or viewed clearly due to lack of access; solar roofing components. Any comments made regarding these items are made as a courtesy only. Note that the inspector does not provide an estimate of remaining life on the roof surface material, nor guarantee that leaks have not occurred in the roof surface, skylights or roof penetrations in the past. Regarding roof leaks, only active leaks, visible evidence of possible sources of leaks, and evidence of past leaks observed during the inspection are reported on as part of this inspection. The inspector does not guarantee or warrant that leaks will not occur in the future. Complete access to all roof and attic spaces during all seasons and during prolonged periods of all types of weather conditions (e.g. high wind and rain, melting snow) would be needed to do so. Occupants should monitor the condition of roofing materials in the future. For older roofs, recommend that a professional inspect the roof surface, flashings, appurtenances, etc. annually and maintain/repair as might be required. If needed, the roofer should enter attic space(s). Regarding the roof drainage system, unless the inspection was conducted during and after prolonged periods of heavy rain, the inspector was unable to determine if gutters, downspouts and extensions perform adequately or are leak-free.
Attic inspection method: Traversed
Roof inspection method: Viewed from ground
Condition of roof structure: Appeared serviceable
Condition of roof surface material: Appeared serviceable
Roof structure type: Trusses
Roof surface material: Slate
Ceiling structure: Ceiling beams
Roof type: A frame
Ceiling insulation material: None visible
Condition of gutters, downspouts and extensions: Appeared serviceable
Approximate attic insulation R value (may vary in areas): N/A, none visible
Vermiculite insulation present: None visible
Vapor retarder: None visible
Condition of roof ventilation: Appeared serviceable
Roof ventilation type: Enclosed soffit vents
15) Insulation is not finished. Recommend a reputable contractor.
Photo
Photo 15-1 No insulation
Photo
Photo 15-2 No insulation
Electric service condition: Required repair, replacement and/or evaluation (see comments below)
Primary service type: Overhead
Number of service conductors: 2
Service voltage (volts): 120-240
Estimated service amperage: 100 Squared D
Primary service overload protection type: Circuit breakers
Service entrance conductor material: Not determined (components inaccessible or obscured)
Main disconnect rating (amps): Not determined
System ground: Ground rod(s) in soil, Cold water supply pipes
Condition of main service panel: Appeared serviceable
Condition of sub-panel(s): Appeared serviceable
Location of main service panel #A: Basement
Location of sub-panel #C: Building exterior
Location of main disconnect: Breaker at top of main service panel
Condition of branch circuit wiring: Serviceable
Ground fault circuit interrupter (GFCI) protection present: Yes
Smoke alarms installed: Installed and appear to be functioning properly at this time
Carbon monoxide alarms installed: Yes and appeared to be working property at this time
16) Exposed ground rod. This is a trip hazard. Recommend a reputable licensed electrical contractor.
Photo
Photo 16-1 Exposed electrical ground rod, slope walk way toward house
17) One or more wall switches were broken or damaged. Recommend a reputable licensed electrical contractor
Photo
Photo 17-1 No power to multiple receptacles in living room
Photo
Photo 17-2 Missing cover attic light switch cover missing in attic. Recommend installing cover
Photo
Photo 17-3 Missing receptible cover in pantry. This will allow for shock are worst. Recommend installing cover
18)  As of today inspection the electrical panel and all it's components are in good working condition.
Photo
Photo 18-1 
Photo
Photo 18-2 
Hvac, Water Heater, and Chimneys
Table of contents
Condition of furnace filters: Appeared serviceable
Condition of water heater: Appeared serviceable
Location for forced air filter(s): Behind return air grill(s)
Type: Tank
Type of combustion air supply: Intake duct
Energy source: Electricity
Condition of venting system: Appeared serviceable
Temperature-pressure relief valve installed: Yes
Condition of cooling system and/or heat pump: Appeared serviceable
Location of water heater: Basement
Cooling system and/or heat pump fuel type: Electric
Hot water temperature tested: Yes
Location of heat pump or air conditioning unit: Building exterior
Condition of venting system: Appeared serviceable
Type: Packaged unit
Capacity (in gallons): 40
Condition of controls: Appeared serviceable
Water temperature (degrees Fahrenheit): 120
Condition of forced air heating/(cooling) system: Appeared serviceable
Forced air heating system fuel type: Natural gas
Estimated age of forced air furnace: 1 year 3 months old
Location of forced air furnace: Basement
Forced air system capacity in BTUs or kilowatts:
Condition of forced air ducts and registers: Appeared serviceable
Cooling system and/or heat pump fuel type: Carrier R410a/Natural gas
Location of heat pump or air conditioning unit: Building exterior, Back of house
19) Extension tube missing. This will allow for scalding. Recommend installing.
Photo
Photo 19-1 No drain pipe
Photo
Photo 19-2 Water heater label
20) As of today's inspection all HVAC components are in good working conditions.
Photo
Photo 20-1 Ac serial number
Photo
Photo 20-2 Ac/furnace label
Photo
Photo 20-3 Filter clean
21) As of today's inspection the water heater and all it's components are in good working condition
Photo
Photo 21-1 
Limitations: The following items are not included in this inspection: household appliances such as stoves, ovens, cook tops, ranges, warming ovens, griddles, broilers, dishwashers, trash compactors, refrigerators, freezers, ice makers, hot water dispensers and water filters; appliance timers, clocks, cook functions, self and/or continuous cleaning operations, thermostat or temperature control accuracy, and lights. Any comments made regarding these items are as a courtesy only. Note that the inspector does not provide an estimate of the remaining life of appliances, and does not determine the adequacy of operation of appliances. The inspector does not note appliance manufacturers, models or serial numbers and does not determine if appliances are subject to recalls. Areas and components behind and obscured by appliances are inaccessible and excluded from this inspection.
Condition of counters: Appeared serviceable
Condition of cabinets: Appeared serviceable
Condition of sinks and related plumbing: Appeared serviceable
Condition of under-sink food disposal: N/A (none installed)
Condition of dishwasher: Appeared serviceable
Condition of ranges, cooktops and/or ovens: Appeared serviceable
Range, cooktop, oven type: Electric
Type of ventilation: Wall or ceiling mounted fan
Condition of refrigerator: Appeared serviceable
Condition of built-in microwave oven: Appeared serviceable
Type of ventilation: Hood or built into microwave over range or cooktop
22) One or more sink drains were leaking. Recommend a reputable contractor.
Photo
Photo 22-1 
23)  As of today inspection the kitchen and all it's components are in good working condition
Photo
Photo 23-1 
Photo
Photo 23-2 
Photo
Photo 23-3 
Photo
Photo 23-4 
Photo
Photo 23-5 
Plumbing and Bathrooms
Table of contents
Limitations: The following items are not included in this inspection: overflow drains for tubs and sinks; heated towel racks, saunas, steam generators, clothes washers, clothes dryers. Any comments made regarding these items are as a courtesy only. Note that the inspector does not determine the adequacy of washing machine drain lines, washing machine catch pan drain lines, or clothes dryer exhaust ducts. The inspector does not operate water supply or shut-off valves for sinks, toilets, bidets, clothes washers, etc. due to the possibility of valves leaking or breaking when operated. The inspector does not determine if shower pans or tub and shower enclosures are water tight, or determine the completeness or operability of any gas piping to laundry appliances.
Limitations: The following items are not included in this inspection: private/shared wells and related equipment; private sewage disposal systems; hot tubs or spas; main, side and lateral sewer lines; gray water systems; pressure boosting systems; trap primers; incinerating or composting toilets; fire suppression systems; water softeners, conditioners or filtering systems; plumbing components concealed within the foundation or building structure, or in inaccessible areas such as below tubs; underground utilities and systems; overflow drains for tubs and sinks; backflow prevention devices. Any comments made regarding these items are as a courtesy only. Note that the inspector does not operate water supply or shut-off valves due to the possibility of valves leaking or breaking when operated. The inspector does not test for lead in the water supply, the water pipes or solder, does not determine if plumbing and fuel lines are adequately sized, and does not determine the existence or condition of underground or above-ground fuel tanks.
Location #A: Full bath, second floor
Condition of service and main line: Appeared serviceable
Location #B: Half bath, first floor
Water service: Public
Condition of counters: Appeared serviceable
Water pressure (psi): 40
Condition of cabinets: Appeared serviceable
Location of main water shut-off: Basement, Building exterior
Condition of flooring: Appeared serviceable
Condition of supply lines: Appeared serviceable
Condition of sinks and related plumbing: Appeared serviceable
Supply pipe material: PVC plastic
Condition of toilets: Required repair, replacement and/or evaluation (see comments below)
Condition of drain pipes: Appeared serviceable
Condition of bathtubs and related plumbing: Required repair, replacement and/or evaluation (see comments below)
Drain pipe material: Plastic
Condition of shower(s) and related plumbing: Appeared serviceable
Condition of waste lines: Appeared serviceable
Condition of ventilation systems:
Waste pipe material: Plastic
Bathroom and laundry ventilation type: with individual ducts
Vent pipe condition: Not determined (inaccessible, obscured, or water service off)
Gas supply for laundry equipment present: Yes
Vent pipe material: Not determined (inaccessible or obscured)
240 volt receptacle for laundry equipment present: No
Sump pump installed: No
Sewage ejector pump installed: None visible
Condition of sewage ejector pump: Not determined (inaccessible or obscured)
24) The toilet at location(s) #A and B was loose where it attached to the floor. Leaks can occur and Sewer gases can enter living spaces. Recommend a reputable licensed plumbing contractor.
Photo
Photo 24-1 Location A
Photo
Photo 24-2 Location b
Interior, Doors and Windows
Table of contents
Limitations: The following items are not included in this inspection: security, intercom and sound systems; communications wiring; central vacuum systems; elevators and stair lifts; cosmetic deficiencies such as nail-pops, scuff marks, dents, dings, blemishes or issues due to normal wear and tear in wall, floor and ceiling surfaces and coverings, or in equipment; deficiencies relating to interior decorating; low voltage and gas lighting systems. Any comments made regarding these items are as a courtesy only. Note that the inspector does not evaluate any areas or items which require moving stored items, furnishings, debris, equipment, floor coverings, insulation or similar materials. The inspector does not test for asbestos, lead, radon, mold, hazardous waste, urea formaldehyde urethane, or any other toxic substance. Some items such as window, drawer, cabinet door or closet door operability are tested on a sampled basis. The client should be aware that paint may obscure wall and ceiling defects, floor coverings may obscure floor defects, and furnishings may obscure wall, floor and floor covering defects. If furnishings were present during the inspection, recommend a full evaluation of walls, floors and ceilings that were previously obscured when possible. Carpeting and flooring, when installed over concrete slabs, may conceal moisture. If dampness wicks through a slab and is hidden by floor coverings that moisture can result in unhygienic conditions, odors or problems that will only be discovered when/if the flooring is removed. Determining the cause and/or source of odors is not within the scope of this inspection.
Condition of exterior entry doors: Appeared serviceable, Required repair, replacement and/or evaluation (see comments below)
Exterior door material: Wood, Metal
Condition of windows and skylights: Appeared serviceable, Required repair, replacement and/or evaluation (see comments below)
Type(s) of windows: Wood, Metal
Condition of walls and ceilings: Appeared serviceable, Required repairs, replacement and/or evaluation (see comments below)
Wall type or covering: Drywall
Ceiling type or covering: Drywall or plaster
Condition of flooring: Required repairs, replacement and/or evaluation (see comments below)
Condition of concrete slab floor(s): Required repairs, replacement and/or evaluation (see comments below)
Flooring type or covering: Vinyl, linoleum or marmoleum
Condition of stairs, handrails and guardrails: Required repairs, replacement and/or evaluation (see comments below)
25) Stains were found in living room ceiling and 1st floor bathroom ceiling areas. Recommend a reputable licensed plumbing contractor.
Photo
Photo 25-1 Toilet leaking through on 1st level
Photo
Photo 25-2 Water leaking through from tub on 1st level
26) Doors is deteriorated. This is a safety/security hazard. Recommend a reputable contractor.
Photo
Photo 26-1 Need new door
Photo
Photo 26-2 Opening on door framing
27) Lock mechanisms on one or more windows were missing. This will allow for injury are worst. Recommend a reputable contractor.

Safety/security hazard. Recommend a reputable contractor.
Photo
Photo 27-1 No locks on windows
Photo
Photo 27-2 No locks on windows
28) Floors not level. This can be caused by foundation settlement or movement of the foundation, posts and/or beams. Recommend a reputable contractor.
Photo
Photo 28-1 Floor unlevel
Wood Destroying Organism Findings
Table of contents
Limitations: This report only includes findings from accessible and visible areas on the day of the inspection. In addition to the inaccessible areas documented in this report, examples of other inaccessible areas include: sub areas less than 18 inches in height; attic areas less than 5 feet in height, areas blocked by ducts, pipes or insulation; areas where locks or permanently attached covers prevent access; areas where insulation would be damaged if traversed; areas obscured by vegetation. All inaccessible areas are subject to infestation or damage from wood-destroying organisms. The inspector does not move furnishings, stored items, debris, floor or wall coverings, insulation, or other materials as part of the inspection, nor perform destructive testing. Wood-destroying organisms may infest, re-infest or become active at any time. No warranty is provided as part of this inspection.
Visible evidence of active wood-destroying insects: No
Visible evidence of active wood decay fungi: No
Visible evidence of past wood-destroying insects: Yes
Visible evidence of past wood decay fungi: No
Visible evidence of damage by wood-destroying insects: No
Visible evidence of damage by wood decay fungi: No
Visible evidence of conditions conducive to wood-destroying organisms: No
Evidence of prior treatment of wood-destroying insects:

This report has been prepared for the sole and exclusive use of the client indicated above and is limited to an impartial opinion which is not a warranty that the items inspected are defect-free. or the latent or concealed defects may exist as of the date of the inspection or which may have existed in the past or may exist in the future. The report is limited to the components of the property which were visible to the inspector on the date of the inspection and his opinion of their condition at the time of the inspection.