This report published on Thursday, August 10, 2023 8:41:56 AM EDT
This summary page is intended to provide a convenient and cursory preview of some conditions and components that have been identified within this report as needing service. It is obviously not comprehensive and should not be used as a substitute for reading the entire report, nor is it a tacit endorsement of the condition of components or features that may not appear in this summary. Only items relevant to this home are mentioned in this report. Have appropriate licensed contractors further evaluate the listed concerns and defects, as well as the entire systems in question, before close of escrow. Also, a final walk-through inspection should be carried out the day before closing by the new owners to double check the condition of the property, using this report.
This summary is not the entire report. The full report may include additional information of interest or concern to the client. It is strongly recommended that the client promptly read the complete report. For information regarding the negotiability of any item in this report under a real estate purchase contract, contact your real estate agent or attorney. .
As with all home inspection reports please be sure to verify with local code enforcement all local codes that may apply to any needed repairs or issues.
This summary and report are the exclusive property of Porch Light Home Inspections and the client(s) listed in the title. Use of this report by any unauthorized persons is prohibited.
Concerns are shown and sorted according to these types:
Safety
Poses a safety hazard
Major Defect
Correction likely involves a significant expense
Repair/Replace
Recommend repairing or replacing
Repair/Maintain
Recommend repair and/or maintenance
Minor Defect
Correction likely involves only a minor expense
Maintain
Recommend ongoing maintenance
Evaluate
Recommend evaluation by a specialist
Monitor
Recommend monitoring in the future
Comment
For your information
General Information
1) Structures built prior to the mid 1980s may contain lead and/or asbestos. Lead is commonly found in paint and in some plumbing components. The EPA does not recognize newer coats of paint as encapsulating older coats of lead-based paint. Asbestos is commonly found in various building materials such as insulation, siding, and/or floor and ceiling tiles. Laws were passed in 1978 to prohibit usage of lead and asbestos, but stocks of materials containing these substances remained in use for a number of years thereafter. Both lead and asbestos are known health hazards. Evaluating for the presence of lead and/or asbestos is beyond the scope of this inspection. Any mention of these materials in this report is made as a courtesy only, and meant to refer the client to a specialist. Consult with specialists as necessary, such as industrial hygienists, professional labs and/or abatement specialists for this type of evaluation. For information on lead, asbestos and other hazardous materials in homes, visit: https://www.reporthost.com/?EPA https://www.reporthost.com/?CPSC https://www.reporthost.com/?CDC
Grounds
2) The stairs at the entrance to the basement/crawl space posed a fall or trip hazard. Risers should be 7 3/4 inches or shorter. At a minimum, be aware of this hazard, especially when guests who are not familiar with the stairs are present. Recommend that a qualified contractor repair per standard building practices.
3) Minor deterioration (e.g. cracks, holes, settlement, heaving) was found in sidewalks or patios, but no trip hazards were found. The client may wish to have repairs made for cosmetic reasons.
4) Some porches were obscured by carpeting and couldn't be fully evaluated.
Exterior and Foundation
5) The masonry (brick or stone) was deteriorated or damaged in some areas. Where cracks or openings are exposed, water may enter the wall structure causing mold, fungal growth and structural damage. This is a conducive condition for wood-destroying organisms. Recommend that a qualified contractor repair as necessary. For example, by repointing mortar or replacing broken or missing masonry.
Photo 5-1 Photo 5-2
Photo 5-3
Crawl Space
6) The vapor barrier in some areas of the crawl space was loose or askew and/or missing. Soil was exposed as a result and will allow water from the soil to evaporate up into the structure. This is a conducive condition for wood-destroying organisms. A 6 mil black plastic sheet should be placed over all exposed soil with seams overlapped to 24 inches, and not in contact with any wood structural components. The sheeting should be held in place with bricks or stones, not wood. Recommend that a qualified person replace or repair the vapor barrier where necessary and per standard building practices.
7) Cellulose material such as scrap wood and/or cardboard or paper was found in the crawl space. This is a conducive condition for wood-destroying organisms. Recommend removing all cellulose-based debris or stored items.
8) Crawl space pictures
Photo 8-1 Photo 8-2
Photo 8-3 Photo 8-4
Photo 8-5 Photo 8-6
Photo 8-7 Photo 8-8
Photo 8-9 Photo 8-10
Photo 8-11 Photo 8-12
Photo 8-13
Basement
9) Evidence of prior water intrusion was found in one or more sections of the basement. For example, water stains or rust at support post bases, efflorescence on the foundation, etc. Accumulated water is a conducive condition for wood-destroying organisms and should not be present in the basement. Recommend reviewing any disclosure statements available and ask the property owner about past accumulation of water in the basement. The basement should be monitored in the future for accumulated water, especially after heavy and/or prolonged periods of rain. If water is found to accumulate, then recommend that a qualified contractor who specializes in drainage issues evaluate and repair as necessary. Typical repairs for preventing water from accumulating in basements include:
Repairing, installing or improving rain run-off systems (gutters, downspouts and extensions or drain lines)
Improving perimeter grading
Repairing, installing or improving underground footing and/or curtain drains
Ideally, water should not enter basements, but if water must be controlled after it enters the basement, then typical repairs include installing a sump pump.
10) Standing water was found in one or more sections of the basement. Accumulated water can be a conducive condition for wood-destroying organisms and should not be present in the basement. Review any disclosure statements available and ask the property owner about past accumulation of water in the crawl space. Recommend that a qualified contractor who specializes in drainage issues evaluate and repair as necessary. Typical repairs for preventing water from accumulating in basements include:
Repairing, installing or improving rain run-off systems (gutters, downspouts and extensions or drain lines)
Improving perimeter grading
Repairing, installing or improving underground footing and/or curtain drains
Ideally, water should not enter basements, but if water must be controlled after it enters the basement, then typical repairs include installing a sump pump.
11) The basement exterior entry door appeared to be leaking, or has leaked in the past based on visible stains. At a minimum, monitor this door in the future to determine if active leaks exist. If leaks are confirmed, a qualified person should repair as necessary to prevent water from infiltrating the basement. Note that leaks are a conducive condition for wood-destroying organisms.
12) Minor cracks were found in the concrete slab floor. These are common and appeared to be only a cosmetic issue.
Roof
13) Stains were found on one or more gutters that indicate past leaks have occurred. However, the inspector was unable to verify that the gutters do or don't leak because of lack of recent rainfall. Monitor the gutters in the future while it's raining to determine if gutters leak. If they do, then recommend that a qualified person repair as necessary to prevent water from coming in contact with the building or accumulating around the building foundation.
Photo 13-1 Southwestern side
14) Normally the inspector attempts to traverse roof surfaces during the inspection. However, due to type of roof covering (slippery or fragile) and/or slippery conditions, the inspector was unable to traverse the roof and wasn't able to fully evaluate the entire roof surface.
Attic and Roof Structure
15) Some attic areas and roof structures were inaccessible due to possible damage to insulation if traversed and/or lack of permanent walkways. These areas were not evaluated and are excluded from the inspection.
16) Attic pictures
Photo 16-1 Photo 16-2
Photo 16-3 Photo 16-4
Photo 16-5 Photo 16-6
Photo 16-7 Photo 16-8
Photo 16-9
Garage or Carport
17) No photoelectric sensors were installed for one or more garage vehicle doors' automatic opener. These have been required on all automatic door openers since 1993 and improve safety by triggering the door's auto-reverse feature without need for the door to come in contact with the object, person or animal that is preventing the door from closing. Recommend that a qualified contractor install photoelectric sensors where missing for improved safety. For more information on garage door safety issues, visit: https://www.reporthost.com/?GDPES
18) The roof surface appeared to be nearing the end of its service life and will likely need replacing in the near future. Recommend discussing replacement options with a qualified contractor, and budgeting for a replacement roof surface in the near future.
19) One or more minor cracks (1/8 inch or less) were found in the block wall. These didn't appear to be a structural concern, but recommend sealing them to prevent water infiltration and monitor them in the future. Numerous products exist to seal such cracks including hydraulic cement, non-shrinking grout, resilient caulks and epoxy sealants.
Photo 19-1 Photo 19-2
20) Weatherstripping sealing one or more garage vehicle doors was missing, damaged and/or substandard. Recommend replacing or installing weatherstripping where necessary to prevent water and/or pest intrusion.
21) One or more exterior doors had minor damage and/or deterioration. Although serviceable, the client may wish to repair or replace such doors for appearances' sake.
22) Minor cracks were found in the concrete slab floor. These are common and appeared to be only a cosmetic issue.
23) Normally the inspector attempts to traverse roof surfaces during the inspection. However, due to type of roof covering (slippery or fragile) and/or slippery conditions, the inspector was unable to traverse the roof and wasn't able to fully evaluate the entire roof surface.
24) The garage perimeter were obscured by stored items. In general, the inspector does not move personal belongings or debris. All areas or items that are obscured, concealed or not readily accessible are excluded from this inspection. The client should be aware that when stored items, vehicle(s) and/or debris are eventually moved, damage or problems that were not noted during the inspection may be found.
Electric
25) Energized "knob and tube" wiring was found at one or more locations in the attic. This type of wiring was commonly installed prior to 1950. It is ungrounded and considered unsafe by today's standards. Over time, the wire's insulation can become brittle and fall apart or wear thin, resulting in exposed conductors and a risk of shock and/or fire. This wiring is also easily damaged by covering it with insulation (a common practice), and incorrectly tapping new wiring into it.
It is not within the scope of this inspection to determine what percentage of this property's wiring is of the knob-and-tube type, or to determine what percentage of the knob and tube wiring is energized versus abandoned. Recommend that a qualified electrician evaluate this wiring and make repairs or replace wiring as necessary.
Note that some insurance companies may be unwilling to offer homeowner's insurance for properties with knob and tube wiring. Consult with your insurance carrier regarding this. For more information, visit: https://www.reporthost.com/?KNOBTUBE
Photo 25-1
26) The main panel breakers were not being used. The power was directed to the Generac generator panel. The breakers in that panel were being used. The electric service was configured so that too many hand movements were necessary to turn off all power for the service. Six or fewer circuit breakers should be required to turn off all power to a residence. This is a potential safety hazard during an emergency when the power needs to be turned off quickly. Recommend that a qualified electrician evaluate and repair per standard building practices.
27) Panels were located in a closet. This is not an approved location for electric panels per current standard building practices. Recommend that a qualified electrician move the panel(s) or make repairs per standard building practices.
28) Panels had inadequate working space. This is a safety hazard when opening or working in panels. Electric panels should have the following clearances:
An open area 30 inches wide by 3 feet deep in front of the panel
6 feet 6 inches of headroom in front of the panel
The wall below the panel is clear to the floor
The center of the grip of the operating handle of the switch or circuit breaker not more than 6 feet 7 inches above the floor or working platform
Recommend that a qualified contractor repair or make modifications per standard building practices. If panels must be opened for repairs, then a qualified electrician should perform repairs.
29) One or more modern, 3-slot electric receptacles were found with an open ground. Three-slot receptacles should have a hot, a neutral and a ground wire connected. Homeowners often install new 3-slot receptacles on older, 2-wire circuits that only have hot and neutral wires. This is a shock hazard when appliances that require a ground are used with these receptacles. Examples of such appliances include computers and related hardware, refrigerators, freezers, portable air conditioners, clothes washers, aquarium pumps, and electrically operated gardening tools. Where the electric system was installed prior to when grounded circuits were required (1960s), it is permissible to replace 3-slot receptacles with 2-slot receptacles to prevent appliances that require a ground from being plugged in to an ungrounded circuit. However, the client should be aware of this limitation when planning use for various rooms, such as an office. For newer electric systems, circuits should be repaired so grounded, 3-wire cables provide power to 3-slot receptacles. Recommend that a qualified electrician repair per standard building practices.
30) A 3-slot receptacle was installed for the clothes dryer. Most modern clothes dryers use both 120 and 240 volts (120 for timers and motors, and 240 for heating elements) and either require or are more safely installed with a 4-slot receptacle. With 3-conductor wiring, the ground wire rather than a neutral wire is used to carry the return current back for the 120 volt leg. The clothes dryer's metal frame can become energized if the neutral wire becomes loose at the receptacle or panel. While 3-wire clothes dryer circuits were allowed prior to 1996 and are commonly found, they are considered unsafe due to the risk of shock. Recommend that a qualified electrician convert this to a 4-wire circuit. Note that this may require installing a new circuit wire from the panel to the clothes dryer location.
31) Light fixtures with fully or partially exposed incandescent/fluorescent bulbs were installed in one or more closets. This is a fire hazard. Flammable stored items can come into contact with hot bulbs, or hot fragments from broken bulbs can fall on combustible materials. Closet lighting should use fluorescent light fixtures or fully enclosed incandescent fixtures. Installing a compact fluorescent lamp in a lamp holder is not an acceptable practice. If globes or covers are missing, they should be replaced. Otherwise recommend that a qualified electrician replace closet lights per standard building practices. At a minimum replace with LED bulbs.
32) One or more smoke alarms were missing, damaged, or missing components. Smoke alarms should be replaced as necessary. For more information, visit: https://www.reporthost.com/?SMKALRM
33) One or more cover plates for switches, receptacles or junction boxes were missing or broken. These plates are intended to contain fire and prevent electric shock from occurring due to exposed wires. Recommend that a qualified person install cover plates where necessary.
34) 2-slot receptacles rather than 3-slot, grounded receptacles were installed in one or more areas. These do not have an equipment ground and are considered unsafe by today's standards. Appliances that require a ground should not be used with 2-slot receptacles. Examples of such appliances include computers and related hardware, refrigerators, freezers, portable air conditioners, clothes washers, aquarium pumps, and electrically operated gardening tools. The client should be aware of this limitation when planning use for various rooms, such as an office. Upgrading to grounded receptacles typically requires installing new wiring from the main service panel or sub-panel to the receptacle(s), in addition to replacing the receptacle(s). Consult with a qualified electrician about upgrading to 3-wire, grounded circuits.
35) The ground fault circuit interrupter (GFCI) receptacles (kitchen and bathroom) and/or circuit breakers were defective. Because of this, the inspector was unable to determine if all electric receptacles that should be protected by GFCI devices, were protected. After defective GFCI devices have been replaced or repaired, recommend that a qualified electrician verify that receptacles throughout the house have GFCI protection per standard building practices, and make repairs if necessary.
36) The legend for circuit breakers in panels was missing, incomplete, illegible or confusing. This is a potential shock or fire hazard in the event of an emergency when power needs to be turned off. Recommend correcting the legend so it's accurate, complete and legible. Evaluation by a qualified electrician may be necessary.
37) The side door's doorbell appeared to be inoperable. Recommend that a qualified person repair as necessary.
38) One or more screws that attach the cover or dead front to panels were missing or not installed. Recommend installing screws where missing so the cover or dead front is secure. Only screws with blunt tips approved for this purpose should be installed, so wiring inside the panel is not damaged. Because energized wires may be located directly behind screw holes, the client should consider having a qualified electrician replace missing screws.
39) The electric service to this property appeared to be rated at substantially less than 200 amps and may be inadequate. Depending on the client's needs, recommend consulting with a qualified electrician about upgrading to a 200 amp service. Note that the electric service's rating is based on the lowest rating for the meter base, the service conductors, the main service panel and the main disconnect switch. One or more of these components may need replacing to upgrade.
40) One or more light bulbs/fixtures were inoperable (didn't turn on when nearby switches were operated). Recommend further evaluation by replacing bulbs and/or consulting with the property owner. If replacing bulbs doesn't work and/or no other switch(es) can be found, then recommend that a qualified electrician evaluate and repair or replace light fixtures as necessary.
41) Bulbs in one or more light fixtures were missing or broken. These light fixtures couldn't be fully evaluated. If replacement bulbs are inoperable, then recommend that a qualified electrician evaluate and repair or replace light fixtures as necessary.
42) No doorbell was installed at the main entrance. The client wish to have one installed for convenience sake.
Plumbing / Fuel Systems
43) Either no pit liner was installed for the sump pump, or the liner was substandard or significantly deteriorated. Sediment can clog and damage the pump. A pit liner such as a plastic bucket or molded concrete should be installed. Typical dimensions are 18 inches in diameter and 2-3 feet deep. Recommend that a qualified person repair per standard building practices. For more information, visit: https://www.reporthost.com/?IASP
Photo 43-1
44) The inspector did not determine the location of the main water shut-off valve, or verify that a readily accessible shut-off valve in the building exists. Recommend consulting with the property owner to determine if a main shut-off valve exists, locating it yourself, or that a qualified plumber find it if necessary. If no readily accessible main shut-off valve is found in the building, then recommend that a qualified plumber install one so the water supply can be quickly turned off in the event of an emergency, such as when a supply pipe bursts.
45) A sump pump was installed in the basement. These are specialty systems and only a limited evaluation was performed as part of this inspection. The inspector does not determine the adequacy of sump pumps and their associated drainage systems. The presence of a sump pump may indicate that water routinely accumulates below or inside the structure. Recommend asking the property owner how often the sump pump operates and for how long at different times of the year. The client should be aware that the service life of most sump pumps is 5-7 years, and that the pump may need replacing soon depending on its age and how often it operates.
46) One or more drain line traps were substandard (e.g. "S", "U" or drum traps) to current standard building practices. Traps can siphon or run dry and cause sewer gases to enter living spaces. Recommend that a qualified plumber repair per standard building practices. For example, by replacing with modern "P" traps. For more information, visit: https://www.reporthost.com/?TRAPS
Water Heater
47) The hot water temperature was greater than 120 degrees Fahrenheit. This is a safety hazard due to the risk of scalding. The thermostat should be adjusted so the water temperature doesn't exceed 120 degrees. If the water heater is powered by electricity, a qualified person should perform the adjustment, since covers that expose energized equipment normally need to be removed. For more information on scalding dangers, visit: https://www.reporthost.com/?SCALD
Heating, Ventilation and Air Condition (HVAC)
48) The inspector was unable to determine the last service date of the gas forced air furnace. Ask the property owner when it was last serviced. If unable to determine the last service date, or if this system was serviced more than 1 year ago, recommend that a qualified HVAC contractor inspect, clean, and service this system, and make repairs if necessary. For safety reasons, and because this system is fueled by gas, this servicing should be performed annually in the future. Any needed repairs noted in this report should be brought to the attention of the HVAC contractor when it's serviced. For more information visit: https://www.reporthost.com/?ANFURINSP
49) The cover for one or more heating and/or cooling system air filter was missing. Unfiltered air can enter the return air supply and reduce indoor air quality. Recommend that a qualified person repair as necessary. At a minimum cover opening with duct tape.
Fireplaces, Stoves, Chimneys and Flues
50) One or more sections of metal flue pipe for the water heater had a substandard rise or reverse slope. This is a safety hazard due to the risk of exhaust gases entering living spaces. Flue pipes should have a minimum rise of 1/4 inch per foot of length to ensure safe venting and to minimize accumulation of corrosive condensation. Recommend that a qualified contractor repair per standard building practices.
Photo 50-1
51) A "vent-free" gas fireplace or stove was installed. The client should be aware that exhaust gases from these appliances are vented directly into the living space where they are located, not outdoors. Exhaust gases can contain carbon monoxide, nitrogen dioxide, sulfur dioxide, particles and other pollutants. They can also contain very high levels of moisture (up to 25%), which can be be detrimental to a house over time. Unpleasant odors may be emitted.
Vent-free fireplaces or stoves are not allowed in some municipalities. They must be used exactly as described by the manufacturer, normally for limited times, not in bedrooms and not while occupants are sleeping. They must be serviced periodically. Consult with a qualified HVAC contractor knowledgeable of local codes, and that this appliance be evaluated. For more information, visit: https://www.reporthost.com/?VENTFREE
52) The gas fireplace or stove was not fully evaluated because the gas supply was turned off. The inspector only operates normal controls (e.g. on/off switch or thermostat) and does not light pilot lights or operate gas shut-off valves. Recommend that the client review all documentation for such gas appliances and familiarize themselves with the lighting procedure. If necessary, a qualified specialist should assist in lighting such appliances, and make any needed repairs.
Kitchen
53) The inspector was unable to determine if the dishwasher's drain line had a high loop or air gap (e.g. drain line not visible). A high loop is created by routing the drain line up to the bottom surface of the counter top above and securely fastening it to that surface. An air gap is a device that makes the drain line non-continuous. Both of these prevent waste-water backflow from entering the dishwasher, and possibly flooding out of the dishwasher if/when a siphon occurs. Some newer dishwashers have these devices built in. Recommend reviewing the dishwasher's installation instructions, consulting with the property owner and/or having a qualified contractor evaluate further to determine if a high loop and air gap are installed or needed. If not installed, and none is built into the dishwasher, then recommend that a qualified contractor install a high loop and air gap per standard building practices.
Photo 53-1 Photo 53-2
54) Substandard repairs were found at the sink drain (e.g. tape, sealant, non-standard components). Recommend that a qualified individual repair per standard building practices.
Photo 54-1
55) One or more cabinet drawers were loose and/or damaged. Recommend that a qualified person repair as necessary.
Photo 55-1
56) The fan switch on the exhaust hood wouldn’t work every time it was used.
Photo 56-1
57) The supply for the dishwasher and refrigerator was inoperable (e.g. not plugged in) and the inspector was unable to fully evaluate. Repairs may be needed. If concerned, have a qualified person fully evaluate.
Bathrooms, Laundry and Sinks
58) Vinyl floor tiles was installed in the bathroom. Spilled water can penetrate seams and damage the sub-floor. Recommend that a qualified contractor install continuous waterproof flooring in wet areas such as bathrooms.
59) The bathroom with a shower or bathtub didn't have an exhaust fan installed. Moisture can accumulate and result in mold, bacteria or fungal growth. Even if the bathroom has a window that opens, it may not provide adequate ventilation, especially during cold weather when windows are closed or when wind blows air into the bathroom. Recommend that a qualified contractor install exhaust fans per standard building practices where missing in bathrooms with showers or bathtubs.
60) No access or only limited access was available to the back of the clothes washer and dryer, and to utility hook-ups located behind the appliances. The inspector normally attempts to determine the presence of a gas vs. electric power supply, the configuration of the stand pipe, whether the dryer exhaust duct is serviceable, etc. Because of the lack of access, the inspector was unable to fully evaluate and/or describe the hook-ups and appliances.
Interior, Doors and Windows
61) The kitchen exterior door had double-cylinder deadbolt installed, where a key is required to open them from both sides. This can be a safety hazard in the event of an emergency because egress can be obstructed or delayed. Recommend replacing double-cylinder deadbolts with single-cylinder deadbolts where a handle is installed on the interior side.
Photo 61-1
62) Floors in one or more areas were not level. This can be caused by foundation settlement or movement of the foundation, posts and/or beams. Significant repairs may be needed to make floors level. Recommend that a qualified contractor and/or engineer evaluate further. Repairs should be performed by a qualified contractor.
63) One or more windows that were designed to open and close were difficult to open and close. Recommend that a qualified person repair windows as necessary so they open and close easily.
64) Vinyl flooring in one or more areas was damaged. If in a wet area, water can damage the sub-floor as a result. Recommend that a qualified contractor replace or repair flooring as necessary.
Photo 64-1 Kitchen
65) Carpeting in one or more areas was damaged or deteriorated. Recommend that a qualified contractor replace as necessary.
Photo 65-1 Photo 65-2
66) Lock mechanisms on one or more windows were difficult to operate. This can pose a security risk. Recommend that a qualified person repair as necessary.
67) Trim was missing/damaged in one or more areas. Recommend that a qualified person repair as necessary.
68) Minor cracks, nail pops and/or blemishes were found in walls and/or ceilings in one or more areas. Cracks and nail pops are common, are often caused by lumber shrinkage or minor settlement, and can be more or less noticeable depending on changes in humidity. They did not appear to be a structural concern, but the client may wish to repair these for aesthetic reasons. For recurring cracks, consider using an elastic crack covering product: https://www.reporthost.com/?ECC
69) Carpeting in one or more areas was stained or soiled. Recommend having carpeting professionally cleaned as necessary.
70) One or more interior/exterior doors had minor damage and/or deterioration. Although serviceable, the client may wish to repair or replace such doors for appearances' sake.
71) One or more window screens were missing/damaged. These windows may not provide ventilation during months when insects are active.
72) Wallpaper in one or more areas was torn and/or deteriorated.