Exterior and Foundation
12) 
Large gaps at siding and/or trim were filled with caulk. Caulk should only be used to seal gaps 1/4-inch wide or smaller. Caulk is likely to separate with wider gaps and can result in leaks and subsequent water damage or fungal rot. This is a conducive condition for wood-destroying organisms. Recommend that a qualified person repair per standard building practices. For more information, visit:
https://www.reporthost.com/?CAULK
13) 
Trees were in contact with or were close to the building at one or more locations. Damage to the building may occur, especially during high winds, or may have already occurred (see other comments in this report). Recommend that a qualified tree service contractor or certified arborist remove trees as necessary to prevent damage to the building exterior.
14) 
The paint or stain finish in some areas was failing (e.g. peeling, faded, worn, thinning). Siding and trim with a failing finish can be damaged by moisture. Recommend that a qualified contractor prep (e.g. clean, scrape, sand, prime, caulk) and repaint or restain the building exterior where necessary and per standard building practices. Any repairs needed to the siding or trim should be made prior to this.
Roof
15) 
Alligatoring, crazing, fissures and/or cracks were found in one or more areas of the flat or low-slope roof surface. This is often caused by exposure to ultraviolet light (the sun), and eventually results in water penetrating the underlying roof membrane and causing leaks. This is a conducive condition for wood-destroying organisms. Recommend that a qualified contractor evaluate and repair as necessary.
16) 
One or more downspouts were damaged. Rainwater can come in contact with the building exterior or accumulate around the building foundation as a result. This is a conducive condition for wood-destroying organisms. Recommend that a qualified person repair as necessary.
17) 
Moss was growing on the roof. As a result, shingles can lift or be damaged. Leaks can result and/or the roof surface can fail prematurely. Efforts should be made to kill the moss during its growing season (wet months). Typically, zinc or phosphate-based chemicals are used for this and must be applied periodically. For information on various moss treatment products and their pros and cons, visit:
https://www.reporthost.com/?MOSS
Electric
18) 

Splices in service conductors at the service mast head were exposed. Splices should be covered with plastic insulators or tape to prevent exposed, energized wires. This is a potential shock hazard. Recommend that a qualified electrician repair per standard building practices.
19) 

One or more receptacles were broken or damaged. This is a potential shock or fire hazard. Recommend that a qualified electrician replace such receptacles as necessary.
20) 

One or more electric receptacles and/or the boxes in which they were installed were loose and/or not securely anchored. Wire conductors can be damaged due to repeated movement and/or tension on wires, or insulation can be damaged. This is a shock and fire hazard. Recommend that a qualified electrician repair as necessary.
21) 

One or more ground fault circuit interrupter (GFCI) type receptacles had an open ground. Open ground GFCI receptacles will trip, but they won't provide a grounded electric supply for appliances that need them. This is a potential shock hazard. Recommend that a qualified electrician repair per standard building practices. For example, by upgrading to grounded, 3-conductor wiring. In older dwellings constructed when GFCI protection was not required, and in areas where GFCI protection is not required, replacing 3-slot GFCI receptacles with 2-slot receptacles may be an acceptable repair.
22) 

One or more sections of outdoor wiring were exposed and . This is a potential shock hazard. Recommend that a qualified electrician repair per standard building practices. For example, by installing conduit, re-routing wires or replacing wiring.
23) 

The legend for circuit breakers or fuses in panel(s) #A was missing, incomplete, illegible or confusing. This is a potential shock or fire hazard in the event of an emergency when power needs to be turned off. Recommend correcting the legend so it's accurate, complete and legible. Evaluation by a qualified electrician may be necessary.
24) 
One or more screws that attach the cover or dead front to panel(s) #A were missing or not installed. Recommend installing screws where missing so the cover or dead front is secure. Only screws with blunt tips approved for this purpose should be installed, so wiring inside the panel is not damaged. Because energized wires may be located directly behind screw holes, the client should consider having a qualified electrician replace missing screws.
Plumbing / Fuel Systems
27) 

One or more flexible gas supply connectors were routed through a metal cabinet. Solid iron pipe should be used where gas supply lines are routed through holes in metal cabinets. Continued vibration from this equipment may cause the edge of the metal cabinet to wear through the flexible connector, resulting in gas leaks. This is an explosion and/or fire hazard. Recommend that a qualified contractor repair per standard building practices.
28) 

Low flow was found at one or more sinks when multiple fixtures were operated at the same time. Water supply pipes may be clogged or corroded, filters may be clogged or need new cartridges, or fixtures may be clogged. Recommend that a qualified plumber evaluate and repair as necessary.
29) 

Significant corrosion was found in some pipes or fittings. This can indicate past leaks, or that leaks are likely to occur in the future. Recommend that a qualified plumber evaluate and repair as necessary.
30) 
No hose bibs were found. Recommend that a qualified plumber install one or more hose bibs for convenience, and per standard building practices (e.g. frost-free with anti-siphon device).
31) 
One or more sinks or fixtures used mechanical or auto vents. The spring mechanisms in them can fail, resulting in sewer gases entering living spaces, and they have no screen to keep out vermin (mice). "Air admittance valves" (AAV) are recommended instead of these vents. AAVs have no spring to fail and have built-in screens. Recommend that a qualified plumber upgrade mechanical vents to AAVs. For more information, visit:
https://www.reporthost.com/?AUTOVENT
32) 
One or more copper water supply pipes had substandard support or were loose. Leaks can occur as a result. Copper supply pipes should have approved hangers every 6-8 feet. If hangers are in contact with the copper pipe, they should be made of a material that doesn't cause the pipes or hangers to corrode due to contact of dissimilar metals. Recommend that a qualified person install hangers or secure pipes per standard building practices.
33) 

Based on visible components or information provided to the inspector, this property appeared to have a private sewage disposal (septic) system. These are specialty systems and are excluded from this inspection. Comments in this report related to this system are made as a courtesy only and are not meant to be a substitute for a full evaluation by a qualified specialist. Generally, septic tanks should be pumped and inspected every 3 years. Depending on the type of system and municipal regulations, inspection and maintenance may be required more frequently, often annually. Recommend the following:
- Consult with the property owner about this system's maintenance and repair history
- Review any documentation available for this system
- Review inspection and maintenance requirements for this system
- That a qualified specialist evaluate, perform maintenance and make repairs if necessary
For more information, visit:
https://www.reporthost.com/?SEPTIC
Offices, Interior, Doors and Windows
45) 

Fire rated doors are required in some areas of commercial buildings, but not all. They can be rated for between 3 hours and 20 minutes. Such requirements are typically determined by the fire rating of the wall and the use of the door. Fire rated door assemblies must comply with the proper commercial door hardware requirements and be approved as a rated assembly. It is beyond the scope of this inspection to determine whether requirements for fire rated doors are met, or to determine if mechanisms such as automatic latching mechanisms, self closing devices or smoke gaskets are serviceable. Their condition is unknown and they are excluded from this inspection. Any comments regarding such systems or components are made as a courtesy only.
Note that modern fire safety standards require that all fire rated door assemblies be inspected annually by a qualified specialist. Recommend reviewing any available records to determine if such inspections have been performed within the last year. If unable to determine this, or if such inspections were performed more than a year ago, a qualified specialist should perform this inspection.
46) 

Floors in one or more areas were not level. This can be caused by foundation settlement or movement of the foundation, posts and/or beams. Significant repairs may be needed to make floors level. Recommend that a qualified contractor and/or engineer evaluate further. Repairs should be performed by a qualified contractor.
47) 
Some interior door hardware (hinges) were . Recommend that a qualified person repair or replace as necessary.
48) 
One or more walls were cracked. Recommend that a qualified person repair as necessary.