Summary

Client(s):  John & Jane Doe
Property address:  123 Main St
Anywhere, GA 30000
Inspection date:  Thursday, January 1, 2015

This report published on Tuesday, December 3, 2019 7:30:12 PM EST

This report is the exclusive property of this inspection company and the client(s) listed in the report title. Use of this report by any unauthorized persons is prohibited.

Please Note:

The concerns listed below on the summary page are numbered consistently with their corresponding numbers on the report page. Therefore, you may notice that some concerns are not mentioned on the summary page. This is because the concern was not a major priority to warrant it to be listed on the summary page.


American Society of Home Inspectors International Code Council Visa Mastercard

Concerns are shown and sorted according to these types:
Concern typeSafetyPoses a risk of injury or death
Concern typeRepair/ReplaceRecommend repairing or replacing
Concern typeRepair/MaintainRecommend repair and/or maintenance
Concern typeMinor DefectCorrection likely involves only a minor expense
Concern typeMaintainRecommend ongoing maintenance
Concern typeEvaluateRecommend evaluation by a specialist
Concern typeMonitorRecommend monitoring in the future
Concern typeCommentFor your information
Concern typeConducive conditionsConditions conducive for wood destroying insects or organisms (Wood-soil contact, shrubs in contact with siding, roof or plumbing leaks, etc.)


Exterior
1) One or more light fixtures are damaged and/or deteriorated. A qualified electrician should evaluate and repair or replace light fixtures where necessary.
Photo
Photo 1-1 
2) Conducive conditionsOne or more downspouts have no extensions, or have extensions that are ineffective. This can result in water accumulating around the structure's foundation, or in basements and crawl spaces if they exist. Accumulated water is a conducive condition to wood destroying insects and organisms, and may also cause the foundation to settle and possibly fail over time. Repairs should be made as necessary, such as installing or repositioning splash blocks, or installing and/or repairing tie-ins to underground drain lines, so rain water is carried at least several feet away from the structure to soil that slopes down and away from the structure.
Photo
Photo 2-1 
3) Conducive conditionsVegetation such as trees, shrubs and/or vines are in contact with or less than one foot from the structure's exterior. Vegetation can serve as a conduit for wood destroying insects and may retain moisture against the exterior after it rains. Vegetation should be pruned and/or removed as necessary to maintain a one foot clearance between it and the structure's exterior.
Photo
Photo 3-1 
4) Conducive conditionsThe exterior finish in some areas is failing. A qualified contractor should prep (pressure wash, scrape, sand, prime caulk, etc.) and repaint or restain areas as needed and as per standard building practices.
Photo
Photo 4-1 
Photo
Photo 4-2 
Photo
Photo 4-3 

Roof
6) Conducive conditionsAsphalt or tar sealant has been used on metal roofing in one or more areas. This is not a standard building practice since it can trap moisture between the metal and the sealant and accelerate rusting and/or corrosion. It's likely this roof has had active leaks and was repaired by someone other than a qualified roofing contractor. A qualified roofing contractor should evaluate and make repairs as necessary.
Photo
Photo 6-1 
Photo
Photo 6-2 
7) Conducive conditionsStanding water was found on the flat roof. It should evaporate within 48 hours after it rains. If standing water remains after 48 hours, then the roof installation is likely substandard. A qualified roofing contractor should evaluate and repair if necessary to prevent prolonged standing water.
Photo
Photo 7-1 
8) Conducive conditionsOne or more "rubber boot" flashings are damaged or deteriorated and may result in leaks or vermin intrusion. A qualified contractor should replace flashings where necessary.
Photo
Photo 8-1 
9) Conducive conditionsOne or more sections of metal roofing have a failing paint finish. For example, peeling and/or missing paint. A qualified contractor should repaint metal panels where necessary.
Photo
Photo 9-1 

Heating and cooling
14) Insulation for the outside condensing unit's refrigerant lines is damaged, deteriorated and/or missing in one or more areas. This may result in reduced efficiency and increased energy costs. A qualified heating and cooling contractor should replace insulation as necessary.
Photo
Photo 14-1 
Photo
Photo 14-2 
15) Air handler filter(s) should be checked monthly in the future and replaced or washed as necessary.
Photo
Photo 15-1 
Photo
Photo 15-2 
Photo
Photo 15-3 
Photo
Photo 15-4 
Photo
Photo 15-5 
Photo
Photo 15-6 

Plumbing and laundry
19) Conducive conditionsOne or more active leaks were found at water line at left rear corner of the warehouse. A qualified plumber should evaluate and repair as necessary.
Photo
Photo 19-1 
Photo
Photo 19-2 

Kitchen
20) One or more electric receptacles have reverse-polarity wiring, where the hot and neutral wires are reversed. This is a safety hazard due to the risk of shock. A qualified electrician should evaluate and make repairs as necessary.
Photo
Photo 20-1 
21) One or more faucets leak by handle(s) or at their base when turned on. A qualified plumber should evaluate and repair as necessary.
Photo
Photo 21-1 

Bathrooms
27) Conducive conditionsOne or more exhaust fans is inoperable or provides inadequate air flow. Moisture may accumulate as a result. A qualified contractor should evaluate and replace the fan or make repairs as necessary. Ladies restroom in main office area.
Photo
Photo 27-1 

Interior rooms
32) Cover plate(s) are missing from one or more electric boxes, such as for receptacles, switches and/or junction boxes. They are intended to contain fire and prevent electric shock from exposed wires. This is a safety hazard due to the risk of fire and shock. Cover plates should be installed where missing.
Photo
Photo 32-1 
33) Conducive conditionsStains and elevated levels of moisture were found in one or more ceiling areas. The stain(s) appear to be due to roof leaks. A qualified contractor should evaluate and repair as necessary. Located at front right side of warehouse.
Photo
Photo 33-1 
Photo
Photo 33-2 
Photo
Photo 33-3 Infrared shows evidence of moisture.
34) The weatherstrip around one or more exterior entry doors is missing and/or deteriorated. Weatherstrip should be installed where missing and/or replaced where deteriorated, and by a qualified contractor if necessary.
Photo
Photo 34-1 
Photo
Photo 34-2 
Photo
Photo 34-3 
35) Carpeting in one or more rooms is damaged and/or significantly deteriorated. Recommend replacing carpeting where necessary.
Photo
Photo 35-1 
Photo
Photo 35-2 
36) Carpeting in one or more rooms is soiled and/or stained. Recommend having carpeting professionally cleaned as necessary.
Photo
Photo 36-1 
Photo
Photo 36-2 
Photo
Photo 36-3