View as PDF

View summary

HHH Inspection services

http://www.reporthost.com/hhhinsp
bmwhuntzinger@gmail.com
(916) 768-6135
Lincoln CA
Inspector: Mike Huntzinger
CREIA California Real Estate Inspection Assocation
(President 2011-2012) #0155494

Your Home and Pool Inspection

Client(s):  David Morro & Joana Fong
Property address:  3465 Big Oak Dr
Foresthill CA 95631-9209
Inspection date:  Friday, November 5, 2021

This report published on Tuesday, February 8, 2022 5:13:38 PM PST

This report is the exclusive property of this inspection company and the client(s) listed in the report title. Use of this report by any unauthorized persons is prohibited.

This report contains technical information. If you were not present during this inspection, please call us to arrange for a verbal review with your inspector. If you choose not to consult with the inspector, we can not be held liable for your understanding or misunderstanding of this report's contents.

California Real Estate Inspection Association Inspection Training Associates


P.S. for printing a shorter version use the summery version to print, this will print all the words with out the pictures.
Thank You , please feel free to call me for any questions or need a contractor to do repairs. 916-768-6135

How to Read this Report
This report is organized by the property's functional areas.  Within each functional area, descriptive information is listed first and is shown in bold type.  Items of concern follow descriptive information. Concerns are shown and sorted according to these types:
Concern typeSafetyPoses a risk of injury or death
Concern typeRepair/ReplaceRecommend repairing or replacing
Concern typeRepair/MaintainRecommend repair and/or maintenance
Concern typeMinor DefectCorrection likely involves only a minor expense
Concern typeMaintainRecommend ongoing maintenance
Concern typeEvaluateRecommend evaluation by a specialist
Concern typeMonitorRecommend monitoring in the future
Concern typeServiceableItem or component is in serviceable condition
Concern typeMoisture/waterConditions conducive for wood destroying insects or organisms, or wood rot
Concern typeConducive conditionsConditions conducive for wood destroying insects or organisms (Wood-soil contact, shrubs in contact with siding, roof or plumbing leaks, etc.)

Click here for a glossary of building construction terms.Contact your inspector If there are terms that you do not understand, or visit the glossary of construction terms at https://www.reporthost.com/glossary.asp

Table of Contents

General information
Exterior/Grounds
Electric service
Roof
Garage
Kitchen
Water heater
Heating and cooling
Plumbing
Bathrooms / Laundry / Sinks
Fireplaces, woodstoves and chimneys
Interior rooms
Attic
Crawl space
Swimming Pool
Spa

View summary

General information
Table of contents
Report number: 11052021
Structures inspected: Tri-level home and pool
Type of building: Single family
Age of building: 2011
Time started: 1:00pm
Time finished: 5:30
Inspection Fee.$: 800
Payment method: Check
Present during inspection: Client(s), Realtor(s)
Occupied: No
Weather conditions: Clear
Temperature: Cool, 68
Ground condition: Wet
Foundation type: Unfinished basement, Crawlspace, Post and pier
The following items are excluded from this inspection: Private sewage disposal system, Built-in sound system, Intercom system, Generator system
1) Recalls on consumer products and product safety alerts are almost added daily, if client is concerned about appliances or other items installed in the home that may be on such lists, please go to the following web site for more info. www.recalls.gov or http://www.cpsc.gov/

In addition to information on the most recent recalls, there are links to the Web sites of all six contributing agencies where earlier recalls are listed, among with safety tips and helpful information.
2) INSECT INFESTATION

Evidence associated with wood-destroying pests and organisms was observed at the (crawl space).
NOTE: Only a Branch III, Structural Pest Control Operator or Field Representative can legally identify wood-destroying pests and organisms.
Please refer to the wood-destroying pest and organism report for further information.
(If an inspection report is not available or has not been performed, we recommend the advice and services of a qualified California State Licensed Branch III, Structural Pest Control Company to perform a full inspection and report issuance on the subject property.)
eating the scraps of wood and cardboard.
Photo
Photo 2-1 Termites in debri
Exterior/Grounds
Table of contents
Footing material: Poured in place concrete
Foundation material: Poured in place concrete
Apparent wall structure: Wood frame
Wall covering: Stucco
Driveway material: Asphalt
Sidewalk material: Poured in place concrete
Exterior door material: Solid core wood
3) One or more ground fault circuit interrupter (GFCI) electric receptacles did not trip when tested at spa. This is a safety hazard due to the risk of shock. A qualified electrician should evaluate and repair as necessary.
Photo
Photo 3-1 GFCI is bad at pool
4) Cover plate(s) are missing from one or more electric boxes, such as for receptacles, switches and/or junction boxes. They are intended to contain fire and prevent electric shock from exposed wires. This is a safety hazard due to the risk of fire and shock. Cover plates should be installed where missing.
Photo
Photo 4-1 Missing coverplate at garage area
Photo
Photo 4-2 Missing cover at front door
5) One or more outside faucets are missing/defective backflow prevention devices. These devices reduce the likelihood of polluted or contaminated water entering the potable water supply. This condition can occur when an outside faucet is left in the "on" position with a hose connected and the sprayer head turned off. When pressure in the system fluctuates, water can be drawn back into the water supply pipes from the house. If a chemical sprayer is being used with the hose, those chemicals can enter the water supply pipes.

Recommend installing backflow prevention devices on all exterior hose bibs where missing. They are available at most home improvement stores and are easily installed. For more information, visit: http://edis.ifas.ufl.edu/BODY_AE079
6) Conducive conditionsOne or more driveway or yard drains appear to be inadequate and may not keep water away from the structure or prevent water from ponding. A qualified contractor should evaluate and make repairs as necessary, such as replacing and/or installing additional drains.
Photo
Photo 6-1 Add drains
7) Conducive conditionsOne or more gutters are poorly sloped so that significant amounts of water accumulate in them rather than draining through the downspouts. This can cause gutters to overflow, especially when organic debris such as leaves or needles have accumulated in them. A qualified contractor should evaluate and make repairs as necessary, such as correcting the slope in gutters or installing additional downspouts and extensions if necessary.
Photo
Photo 7-1 Not fully drasining
Photo
Photo 7-2 Not draing
8) One or more areas of the grounds around the structure have significantly soggy soil, standing water or indications of accumulated water at times (sediment, dead grass, etc.). Recommend consulting with a qualified contractor who specializes in drainage, to determine if or what repairs are needed to provide adequate drainage. Possible repairs may involve grading soil, or installing, repairing and/or replacing underground drains.
9) Conducive conditionsOne or more downspouts are missing. This can result in water accumulating around the structure's foundation, or in basements and crawl spaces if they exist. Accumulated water is a conducive condition to wood destroying insects and organisms, and may also cause the foundation to settle and possibly fail over time. A qualified contractor should install downspout(s) where missing. Also recommend installing extensions such as splashblocks or tie-ins to underground drain lines as necessary to carry rainwater away from the house.
Photo
Photo 9-1 Add downspouts
10) Conducive conditionsOne or more crawl space/garage vent screens are lacking or blocked by soil, debris, insulation, stored items or removable panels. This restricts ventilation in the crawl space and may result in increased levels of moisture inside. Materials or items blocking vents should be removed.
Also add a screen at stairs
Photo
Photo 10-1 No screen
11) Conducive conditionsSiding/trim is incomplete or missing in one or more areas. A qualified contractor should install siding where missing to prevent water and vermin intrusion.
Photo
Photo 11-1 Rocks loose at front
12) Conducive conditionswood rot noted at the rear of the electric main panel, Recommend to repair as needed.
Photo
Photo 12-1 rot
13) One or more downspouts have no extensions or have extensions that are ineffective. This can result in water accumulating around the structure's foundation, or in basements and crawl spaces if they exist. Accumulated water is a conducive condition to wood destroying insects and organisms, and may also cause the foundation to settle and possibly fail over time. Repairs should be made as necessary, such as installing or repositioning splash blocks, or installing and/or repairing tie-ins to underground drain lines, so rainwater is carried at least several feet away from the structure to soil that slopes down and away from the structure.
14) Conducive conditionsRecommend cleaning deck(s) and treating with a sealent claiming to waterproof, block ultraviolet light, and stop mildew.

Add grout also.
Photo
Photo 14-1 Seal and grout
Electric service
Table of contents
Primary service type: Underground
Primary service overload protection type: Circuit breakers
Service amperage (amps): 200
Location of main power meter: Left side of garage
Location of main disconnect: Breaker at top of main service panel
Service entrance conductor material: Copper
System ground: Concrete encased electrode
Main disconnect rating (amps): 200
Branch circuit wiring type: Non-metallic sheathed
Solid strand aluminum branch circuit wiring present: No
Smoke detectors present: Yes
15) One or more ground fault circuit interrupter (GFCI) breakers in the sub-main service panel for the steam gen. is not installed, Recommend a upgrade. This is a safety hazard due to the risk of shock. A qualified electrician should evaluate and make repairs and/or replace circuit breakers as necessary.
Photo
Photo 15-1 REPLACE with a GFI breaker for steam
16) Neutral and equipment ground conductors are combined at one or more sub-panels. This should only occur in the main service panel, and is a safety hazard due to the risk of shock. Neutral conductors should be attached to a "floating" neutral bar not bonded to the panel, while grounding conductors should be attached to a separate grounding bar bonded to the sub panel. A qualified electrician should evaluate and repair as necessary.
Photo
Photo 16-1 neutrals are bonded to grounds
17) Floor electric box is missing caps, Recommend to replace as needed.
Photo
Photo 17-1 Missing caps
18) Loose wire at garage, recommend to add a camera or remove as needed.
Photo
Photo 18-1 Wire loose at gargae
19)
Photo
Photo 19-1 Solar not tested
Photo
Photo 19-2 Main panel at garage at 200 amps
Photo
Photo 19-3 
Photo
Photo 19-4 
Photo
Photo 19-5 
Photo
Photo 19-6 
Photo
Photo 19-7 
Photo
Photo 19-8 
Photo
Photo 19-9 
20)  not tested
Photo
Photo 20-1 Not fired up
Roof inspection method: Traversed
Roof type: Gable
Roof covering: Concrete tile
Estimated age of roof: 2011
Gutter & downspout material: Steel
Roof ventilation: Unable to determine (no access to attic spaces)
21) Conducive conditionsOne or more roofing tiles are defective, chipped and/or cracked. A qualified roofing contractor should evaluate and replace tiles as necessary.
Photo
Photo 21-1 Cracked tile
Photo
Photo 21-2 Cracked
22) Conducive conditionsOne or more roofing tiles have slipped, and are loose. A qualified roofing contractor should evaluate and repair as necessary.
Photo
Photo 22-1 Roof tile not flat
23) All the ridge caps tiles will need to have the holes sealed to prevent any moisture from entering, Recommend to repair as needed.
Photo
Photo 23-1 Seal holes
Photo
Photo 23-2 seal
24)
Photo
Photo 24-1 
Photo
Photo 24-2 
25) Our roof inspection is to report on the type and condition of roofing
materials, missing and/or damaged material, and attachments (excluding antennas, solar systems, etc.) where visible. This does not constitute a warranty, guarantee, roof certification or life expectancy evaluation of any kind.

Roofs are not water tested for leaks. The condition of the roofing underlayment material is not verified/inspected. For further evaluation and a roofing certification we recommend you consult a qualified licensed roofing contractor, a number of lenders may require a roofing certification.

Building's that have tile or wood shingle/shake materials and are going to be tented for termites should be reinspected for possible damage caused by the extermination process before the close of escrow.
26) One or more wall and/or ceiling surfaces between the attached garage and interior living spaces have gaps, holes, or missing or inadequate surface materials. These surfaces are intended to prevent vehicle fumes from entering living spaces and to slow the spread of fire from the garage to living spaces. A qualified contractor should evaluate and make repairs as necessary so the attached garage wall and ceiling surfaces that adjoin living spaces are tightly sealed and fire rated as per standard building practices. Typically these surfaces require a one-hour fire rating.
Photo
Photo 26-1 Hole in garage wall
27) Any and all automatic garage doors sold in California after July 1, 2019, must, by operation of law, include a backup battery system that can adequately provide power to operate the overhead garage doors in the event of a power outage.

Old garage door openers are NOT allowed to be utilized with a new garage door installation.

The imposition of a civil penalty of $1,000 for offending garage door openers or installers.

Bill Highlights Do Not Include:
The new law does not require existing openers to be backed up with batteries, but it is recommended that all homeowners consider upgrading for the increased safety features. When an opener is replaced it must be a battery backed-up system.
28) At the wood-shop door, The trim at the bottom is water stained, Recommend to repair as needed.
Photo
Photo 28-1 Workshop has water damage at lower trim
Photo
Photo 28-2 
29) The overhead filter screen is designed to collect grease, and will need cleaning in the dishwasher to remove the grease, if left uncleaned the filter will become clogged and pose a fire hazard and not remove the air at the stove
30) Water stains and/or minor water damage was found in the shelving or cabinet components below the sink. The client(s) should evaluate and consider having repairs made.
Photo
Photo 30-1 Stains
31) APPLIANCE STATEMENT

"Our "test" is not an evaluation of performance but is only to verify that they "work." It is possible that timers may be defective, garbage disposers may be ineffective, thermostats may be out of calibration, and the appliance can still "pass" our abbreviated test. Appliances can fail at any time without warning. There are insurance policies available to you that may provide some protection. Your agent can supply information on this subject
32)  serviceable.
Photo
Photo 32-1 Serviceable
Photo
Photo 32-2 Serviceable
Photo
Photo 32-3 Serviceable
Water heater
Table of contents
Estimated age: 2011
Type: Instantaneous
Energy source: Propane
33) Gas line to the water heater is under-sized, Recommend a 1" line for max. BTU output.
Photo
Photo 33-1 
Photo
Photo 33-2 Gas line needs to be 1"
Photo
Photo 33-3 
Heating and cooling
Table of contents
Estimated age: 2011
Primary heating system energy source: Propane gas
Primary heat system type: Forced air
Primary A/C energy source: Electric
Primary Air conditioning type: Split system
Distribution system: Flexible ducts
Manufacturer: Trane
Filter location: Behind return air grill
34) The last service date of this system appears to be more than two years ago, or the inspector was unable to determine the last service date. The client(s) should ask the property owner(s) when it was last serviced. If unable to determine the last service date, or if this system was serviced more than two years ago, a qualified heating and cooling contractor should inspect, clean, and service this system, and make repairs if necessary. This servicing should be performed every few years in the future, or as per the contractor's recommendations.
Photo
Photo 34-1 
Photo
Photo 34-2 
Photo
Photo 34-3 
Photo
Photo 34-4 
35) The ambient air test was performed by using thermometers on the air handler of the air conditioner to determine if the difference in temperatures of the supply and return air are at least 20 degrees which indicates that the unit is cooling as intended. The supply air temperature on your system read 52 degrees, and the return air temperature was 74 degrees. This indicates the range in temperature drop is normal.

The furnace is serviceable.
Photo
Photo 35-1 
Photo
Photo 35-2 
Photo
Photo 35-3 
Water pressure (psi): 55
Main water shut-off: Right side of garage
Location of main fuel shut-off: at tank
Visible fuel storage systems: yes
Water service: Private
Service pipe material: Copper
Supply pipe material: Copper
Vent pipe material: Plastic
Drain pipe material: Plastic
Waste pipe material: Plastic
36) Conducive conditionsOne or more active leaks were found in drain and/or waste pipes or fittings at the master tub. A qualified plumber should evaluate and repair as necessary.
Photo
Photo 36-1 Tub leak
Photo
Photo 36-2 Tub leak
Photo
Photo 36-3 stains under leaky tub
37) At the bath sink flex drain pipe is used, not allowed due to glogging issues, Recommend to replace as needed.
Photo
Photo 37-1 Replace flex drain
38) Neither the clothes washer nor dryer were operated or evaluated. They are excluded from this inspection.
Bathrooms / Laundry / Sinks
Table of contents
Limitations: The following items are not included in this inspection: overflow drains for tubs and sinks; bidets, heated towel racks, saunas, steam generators, clothes washers, clothes dryers. Any comments made regarding these items are as a courtesy only. Note that the inspector does not determine the adequacy of washing machine drain lines, washing machine catch pan drain lines, or clothes dryer exhaust ducts. The inspector does not operate water supply or shut-off valves for sinks, toilets, bidets, clothes washers, etc. due to the possibility of valves leaking or breaking when operated. The inspector does not determine if shower pans or tub and shower enclosures are water tight, or determine the completeness or operability of any gas piping to laundry appliances.
Location #A: master
Location #B: jack / jill
Location #C: laundry
Location #D: kitchen
Location #E: guest
Location #F: 1/2 bath
Condition of counters: Appeared serviceable
Condition of cabinets: Appeared serviceable
Condition of sinks and related plumbing: Appeared serviceable
Condition of toilets: Appeared serviceable
Condition of bathtubs and related plumbing: Required repair, replacement and/or evaluation (see comments below)
Condition of shower(s) and related plumbing: Appeared serviceable
Condition of ventilation systems: Appeared serviceable
Condition of laundry facilities: Appeared serviceable
Gas supply for laundry equipment present: Yes
240 volt receptacle for laundry equipment present: Not determined
39) Conducive conditionsMinor moisture damage was found in floor areas by the bathtub at location #A. A qualified person should evaluate and repair as necessary.

under tub in master, due to leaks
40) One or more light fixtures are damaged and/or deteriorated or missing. A qualified electrician should evaluate and repair or replace light fixtures where necessary.
Photo
Photo 40-1 Lense cracked in bath
41) Water damage was found in the shelving or cabinet components below one or more sinks at location #B. A qualified contractor should evaluate and make repairs as necessary.
Photo
Photo 41-1 Stains at hall bath
42) One or more sink faucet handles at location #B were loose. A qualified person should repair or replace as necessary.
Photo
Photo 42-1 Loose faucet in hall
43) The sink drain stopper mechanism at location #A was inoperable. A qualified person should repair or replace as necessary.
Photo
Photo 43-1 Master sink stopper amiss
44) The shower head at location #E was loose. A qualified person should repair or replace as necessary.
Photo
Photo 44-1 Loose shower spray in guest bath
45) Caulk was missing at location #F. A qualified person should repair as necessary.

add backsplash as needed.
46) Minor wear was found at the sink at location #F.

missing aerator
Photo
Photo 46-1 Missing aerator
47) Steam generator under bath, recommend a better surface to place it on.
Photo
Photo 47-1 Serviceable
48) Master heated floors serviceable
Photo
Photo 48-1 Heated floor
Fireplaces, woodstoves and chimneys
Table of contents
Fireplace type: Metal prefabricated
Woodstove type: Metal insert
Chimney type: Metal
49) A significant amount of creosote (1/8 inch or more) is visible in the woodstove flue. A qualified chimney service contractor should inspect, clean, and repair if necessary now and annually in the future. www.atozchimneys.com
50) The living room fireplace has a bad ignitor and did not lite up. Recommend to repair as needed.
Photo
Photo 50-1 Igniter would not work, service
51) Minor cracks, pitting and/or deterioration were found in some fireplace firebrick. However the bricks were not loose and appear to be serviceable. The clients should monitor the condition of the firebricks in the fireplace's firebox in the future. If significant deterioration occurs or if bricks become loose, then a qualified chimney service contractor should evaluate and make repairs as necessary.
Photo
Photo 51-1 Cracked panel
Interior rooms
Table of contents
52) Batteries in all the CO2/smoke alarms should be replaced after taking occupancy, and annually in the future. "Chirping" noises emitted from smoke alarms typically indicate that batteries need replacing. For more information, visit http://www.cpsc.gov/cpscpub/pubs/5077.html
53) One or more ceiling fans appear to be inoperable. Recommend asking the property owner(s) about this, and if necessary, having a qualified electrician evaluate and repair as necessary. this may have a remote that is not present..

may also be dead batteries on remote or missing remote
Photo
Photo 53-1 Fan ,issue, Remote?
54)  Limitations: The following items are not included in this inspection: security, intercom and sound systems; communications wiring; central vacuum systems; elevators and stair lifts; sources of obnoxious odors; cosmetic deficiencies due to normal wear and tear in wall, floor and ceiling surfaces and coverings, or in equipment; deficiencies relating to interior decorating; low voltage and gas lighting systems. Any comments made regarding these items are as a courtesy only. Note that the inspector does not evaluate any areas or items which require moving stored items, furnishings, debris, equipment, floor coverings, insulation or similar materials. The inspector does not test for asbestos, lead, radon, mold, hazardous waste, urea formaldehyde urethane, or any other toxic substance. Some items such as window operability are tested on a sampled basis. The client should be aware that paint may obscure wall and ceiling defects, floor coverings may obscure floor defects, and furnishings may obscure wall, floor and floor covering defects. If furnishings were present during the inspection, recommend a full evaluation of walls, floors and ceilings that were previously obscured when possible. Determining the cause of odors is not within the scope of this inspection.
Inspection method: Partially traversed
Roof structure type: Rafters
Ceiling structure: Ceiling beams
Insulation material: spray foam
Insulation depth: 10" Unable to view area beneath insulation
55) Combustibles such as wood or insulation are in contact with or less than one inch from chimney or gas flue pipes in one or more areas. This is a fire hazard. A qualified contractor should evaluate and make repairs or modifications as necessary so minimum clearances to combustibles are maintained around all chimney and flue pipes as per the manufacturer's specifications. not shure if this applies to the tankless heater in attic but have Jeff see if its ok.
56) Stains were visible on the roof structure or insulation in one or more areas. These areas were dry at the time of the inspection. The stains may be caused by a past leak. Recommend asking the property owner(s) about past leaks. The client(s) should monitor these areas in the future, especially after heavy rains, to determine if active leaks exist. If leaks are found, a qualified roofing contractor should evaluate and repair as necessary.
Photo
Photo 56-1 Leak
Photo
Photo 56-2 water stain
Crawl space
Table of contents
Inspection method: Traversed
Insulation material underneath floor above: spray foam
Pier or support post material: Wood
Beam material: Solid wood
Floor structure above: Engineered wood joists
Vapor barrier present: No
57) Some wiring is loose, unsupported, or inadequately supported. Standard building practices require non-metallic sheathed wiring to be trimmed to length, attached to runners or to solid backing with fasteners at intervals of 4-1/2 ft. or less. Fasteners should be installed within 12 inches of all enclosures. A qualified, licensed electrician should evaluate and repair as necessary. For example, trim wire to length and/or install staples as needed.
58) Conducive conditionsEvidence of prior water intrusion was found in one or more sections of the crawl space. For example, sediment stains on the vapor barrier or foundation, and/or efflorescence on the foundation. Accumulated water is a conducive condition for wood destroying insects and organisms and should not be present in the crawl space. The client(s) should review any disclosure statements available and ask the property owner(s) about past accumulation of water in the crawl space. The crawl space should be monitored in the future for accumulated water, especially after heavy and/or prolonged periods of rain. If water is found to accumulate, a qualified contractor who specializes in drainage issues should evaluate and repair as necessary. Typical repairs for preventing water from accumulating in crawl spaces include:
  • Repairing, installing or improving rain run-off systems (gutters, downspouts and extensions or drain lines)
  • Improving perimeter grading
  • Repairing, installing or improving underground footing and/or curtain drains

Ideally, water should not enter crawl spaces, but if water must be controlled after it enters the crawl space, then typical repairs include installing trenches, gravity drains and/or sump pump(s) in the crawl space.
Photo
Photo 58-1 Wet areas need more vents
Photo
Photo 58-2 
Photo
Photo 58-3 
59) Conducive conditionsThe crawl space ventilation is substandard, at deck area. This may result in high levels of moisture in the crawl space and can be a conducive condition for wood destroying insects and organisms. Standard building practices require one square foot of vent area for 150 to 200 square feet of crawl space. Vents should be evenly distributed and within a few feet of corners to promote air circulation. A qualified contractor should evaluate and install vents as per standard building practices.
Photo
Photo 59-1 add more vents
60) Conducive conditionsThe sheer wall at the rear is beginning to rot due to leaks at the deck area, Recommend to repair as needed.
Photo
Photo 60-1 Wood rot
Photo
Photo 60-2 Wood rot
61) Conducive conditionsCellulose-based debris such as wood scraps, form wood, cardboard and/or paper were found in crawl space. All cellulose-based debris should be removed to avoid attracting wood destroying insects.
Photo
Photo 61-1 remove wood debries
Swimming Pool
Table of contents
Limitations: The following items are not included in this inspection: swimming pool bodies; equipment on timers, remote controls or sensors; underground or concealed piping; motorized covers; waterfalls and related equipment; Ozone generators; ultraviolet light systems; filter backflushing mechanisms. Any comments made regarding these items are as a courtesy only. Note that the inspector does not disassemble filters, remove pool covers, nor determine if swimming pool bodies, filters or skimmers leak, nor determine if swimming pool bodies are level.
Water level: Full
Condition of fences and gates: Appeared serviceable
Fence and gate material: Wrought iron
Condition of body: Appeared serviceable
Body type: Below ground ~
Body material: Pebbletec
Condition of deck: Appeared serviceable
Deck material: Stone
Condition of coping: Appeared serviceable
Coping material: Tile
Condition of pumps, lines and valves: Appeared serviceable
Water is refilled through: Valve
Types of pumps installed: Circulation
Line material: PVC
Condition of filter and related equipment: Appeared serviceable
Filter type: Cartridge
Filter air relief valve installed: Yes
Filter pressure gauge installed: Yes
Filter pressure at time of inspection (psi): 10
Condition of skimmers: Required repair, replacement and/or evaluation (see comments below), missing
Condition of electrical equipment: Appeared serviceable
Location of electrical disconnect: In sub-panel at equipment
Type of wiring: Rigid conduit
62) One or more gates used with pool or spa fencing swung in towards the pool or spa rather than away. Standard building practices require that gates used with pool or spa fencing swing away from the pool or spa. A qualified person should evaluate and repair as necessary, and as per standard building practices. For more information, visit:
http://www.cpsc.gov/CPSCPUB/PUBS/Pool.pdf
Photo
Photo 62-1 Latch on wrong side
63) Storage for chemicals was substandard. This is a potential safety hazard that should be corrected. Standard safety practices require:
  • Chemicals should be out of the reach of children and pets.
  • The original lids on all chemical containers should be used, and lids should be closed lightly when not in use.
  • Different chemicals should not be stacked on top of one another.
  • Chemicals should be stored in a cool, dry, well ventilated area preferably off the floor.
  • Chemicals should not be stored with other flammable items.

For more information, visit:
http://www.safekid.org/pool.htm
64) Drainage from the decking is substandard and may result in surface water draining into the spa, or ponding. Decking should slope a minimum of one inch in six feet of distance. A qualified contractor should evaluate and repair as necessary.
65) The stone and/or caulk in some areas of the decking was missing. A qualified person should repair as necessary.
66) The under water skimmer is missing and needs to be serviced or replaced
67) The basket for the circulation pump was broken or deteriorated. This may allow debris to clog the pump's impeller. A qualified person should replace pump baskets as necessary.
Photo
Photo 67-1 Damaged basket strainer
68) The stone and/or caulk in many areas of the decking was missing. A qualified person should repair as necessary.
Photo
Photo 68-1 Seal pool tiles
69) Low salt noted, Maintain level as needed.
Photo
Photo 69-1 Low salt
Limitations: The following items are not included in this inspection: spa bodies; equipment on timers, remote controls or sensors; underground or concealed piping; motorized covers; waterfalls and related equipment; Ozone generators; ultraviolet light systems; filter backflushing mechanisms. Any comments made regarding these items are as a courtesy only. Note that the inspector does not disassemble filters, nor determine if spa bodies, filters or skimmers leak, nor determine if spa bodies are level.
Water level: Full
70) Storage for chemicals was substandard. This is a potential safety hazard that should be corrected. Standard safety practices require:
  • Chemicals should be out of the reach of children and pets.
  • The original lids on all chemical containers should be used, and lids should be closed lightly when not in use.
  • Different chemicals should not be stacked on top of one another.
  • Chemicals should be stored in a cool, dry, well ventilated area preferably off the floor.
  • Chemicals should not be stored with other flammable items.

For more information, visit:
http://www.safekid.org/pool.htm
71) mice under the spa, Recommend to bate and trap.

NOTE: all reports are viewable for 90 days , please print a copy to save .


If you have any questions on this report or wish to review the home inspection, please call us at (916) 768-6135.

We are happy to review this report with anyone you feel will benefit from a review (handyman, developer, electrician, etc.).

As a Certified Home Inspector Member of the California Real Estate Inspection Association (CREIA), this inspection has been conducted following the CREIA Standards or above standards. To get a copy of these Standards, go to http://www.creia.org/lawsstandards/

California Real Estate Inspection Association Inspection Training Associates