Inspector: Jim Troth

Summary

Client(s):  S. Sample
Property address:  ------------------------
Columbus, Ohio
Inspection date:  Monday, May 12, 2008

This report published on Tuesday, October 30, 2018 7:19:41 PM EDT

This is a summary of a home inspection performed on the property. It is recommended that the entire report be read.



Exterior
3) Safety, Repair/Replace, Conducive conditions - Flashing is missing from above one or more deck ledger boards. This can cause moisture to accumulate between the ledger board(s) and the structure. Rot may result in this area and cause the ledger board fasteners to fail. The deck may separate from the structure in this event and poses a significant safety hazard. A qualified contractor should install flashing above ledger board(s) where necessary. For more information on installing deck ledger boards visit: http://www.hometime.com/Howto/projects/decks/deck_4.htm

And for more information on building safe decks in general, visit: http://www.thisoldhouse.com/toh/knowhow/exteriors/article/0,16417,212625,00.html
4) Repair/Replace - One or more wooden deck support posts are in contact with soil. This is a conducive condition for wood destroying insects and organisms. However no damage from wood destroying insects or organisms was found. Standard building practices require that there be at least 6" of space between any wood and the soil below, even if the wood is treated. If possible, soil should be removed or graded so a 6" clearance is maintained. Otherwise recommend installing borate based Impel rods to prevent rot.
5) Repair/Replace - The perimeter grading slopes towards the structure in one or more areas or should be improved. This can result in water accumulating around the structure's foundation, or in basements and crawl spaces if they exist. Accumulated water is a conducive condition to wood destroying insects and organisms. Wet soil may also cause the foundation to settle and possibly fail over time. Recommend grading soil so it slopes down and away from the structure with a slope of at least 5% (10% or better is optimal) for at least 6 feet.

Roof
11) Repair/Replace, Evaluate - Four or more composition shingles are damaged, deteriorated and/or missing, and should be replaced. Leaks may occur as a result. A qualified roofing contractor should evaluate and make repairs as necessary.
12) Repair/Replace, Evaluate - Approximately one composition shingles has raised, most likely due to nails that have loosened. Leaks may occur as a result. A qualified roofing contractor should evaluate and make repairs as necessary, such as reseating nails.

Garage
17) Safety, Repair/Replace, Evaluate - The auto-reverse mechanism on the vehicle door opener is inoperable or requires too much force to activate. This is a safety hazard, especially for small children. A qualified contractor should evaluate and repair as necessary. For more information on garage door safety issues, visit: http://www.cpsc.gov/cpscpub/pubs/523.html or http://www.ohdstl.com/safety.html
18) Safety, Repair/Replace - The garage-house door isn't equipped with an automatic closing device such as sprung hinges. This door should close and latch automatically to prevent vehicle fumes from entering living spaces and/or to slow the spread of fire from the garage to living spaces. A qualified contractor should install automatic closing device(s) as necessary, and as per standard building practices, so this door closes and latches automatically.
19) Safety, Repair/Replace - The wall-mounted control for the vehicle door opener is less than five feet off the floor, or within reach of children. This is a safety hazard, especially for children. Children should not be able to operate vehicle door openers. Controls for door openers should be relocated as necessary so they're at least 5 feet above floors and/or out of reach of children. For more information on garage door safety issues, visit: http://www.cpsc.gov/cpscpub/pubs/523.html or http://www.ohdstl.com/safety.html

Attic
21) Safety, Repair/Replace - Extension cords are being used as permanent wiring in one or more areas. They should only be used for portable equipment on a temporary basis. Using extension cords as permanent wiring poses a fire and shock hazard, and is an indication that wiring is inadequate and should be updated. Extension cords may be undersized. Connections may not be secure, resulting in power fluctuations, damage to equipment, and sparks that could start a fire. Extension cords should be removed as necessary, or a qualified electrician should evaluate and make repairs as necessary. For example, install additional circuits and/or electric receptacles.
22) Repair/Replace, Evaluate - Two or more areas of the roof structure were wet or had elevated levels of moisture at the time of the inspection. There appears to be an active leak in the roof or structure exterior. A qualified contractor should evaluate and repair as necessary.

See also the comments regarding the roof.
23) Repair/Replace - Ceiling insulation is uneven in some areas. This is likely due to someone having walked on or through the insulation. Recommend installing additional insulation where necessary to restore the original R rating.

Plumbing and laundry
36) Safety, Repair/Replace - The clothes dryer is equipped with a vinyl or foil, accordion-type, flexible exhaust duct. The U.S. Consumer Product Safety Commission considers these types of ducts to be unsafe, and a fire hazard. These types of ducts can trap lint and are susceptible to kinks or crushing, which can greatly reduce the air flow. This duct should be replaced with a rigid or corrugated semi-rigid metal duct, and by a qualified contractor if necessary. Most clothes dryer manufacturers specify the use of a rigid or corrugated semi-rigid metal duct. For more information on dryer safety issues, see http://www.cpsc.gov/CPSCPUB/PUBS/5022.html

Fireplaces, woodstoves and chimneys
38) Repair/Replace - A wood burning fireplace has been converted to use gas logs, and no glass doors are installed on the fireplace. For gas conversions like this, the fireplace damper is modified so it is permanently open to prevent combustion gases from the pilot light and main burners accumulating in living spaces. Since the damper is always open, unconditioned air from outside can enter living spaces through the chimney, and conditioned air from inside can exit through the chimney. This can result in higher energy costs from heating and cooling. The client(s) should consider having a qualified chimney service contractor install glass doors on the fireplace to reduce or eliminate this air flow.

Basement
40) Safety, Repair/Replace, Evaluate - No ground fault circuit interrupter (GFCI) protection device is visible for the sump pump electric supply. A qualified electrician should determine if a GFCI protection device (receptacle or circuit breaker) exists for the sump pump and install one if missing to reduce the danger of electric shock.

Kitchen
42) Repair/Replace - The range hood fan vents into the kitchen rather than outdoors. Ventilation may be inadequate and moisture may accumulate indoors. Recommend having a qualified contractor make modifications as necessary as per standard building practices so the range hood fan vents outdoors.

Common

Bathrooms
44) Repair/Replace, Evaluate - Elevated levels of moisture, soft floor structure, and/or dark staining at vinyl flooring around the base of two of the toilets. A qualified contractor should remove toilet(s) where necessary for further evaluation and repairs. The floor structure and flooring material below may need repair or replacement. Adequate time should be allowed for enclosed, wet floor structures to dry out after repairs are made and before floor cavities are closed off to prevent mold growth.

Half bath and the bathroom in the hallway.
45) Repair/Replace, Evaluate - The "flapper valve" in one or more toilets did not reseat after flushing. Significant amounts of water can be lost through such leaks. A qualified plumber should evaluate and repair or replace components as necessary.

half bath
46) Repair/Replace - Drain screen missing for the master shower stall.

Interior rooms
49) Safety, Repair/Replace - Gaps larger than four inches were found in one or more guardrails. This is a safety hazard, especially for small children. A qualified contractor should make modifications as necessary so gaps in guardrails do not exceed four inches. For example, installing additional balusters or railing components.

Small area at bottom of basement steps.
51) Repair/Replace - The weatherstrip around one or more exterior entry doors is not sealing properly. Weatherstrip should be installed where missing and/or replaced where deteriorated, and by a qualified contractor if necessary.

Front door