Summary

Client(s):  Luxury / Large Home Sample Report
Property address:  XXXXXX XXXXXXX
Dublin, OH 430
Inspection date:  Saturday, November 25, 2017

This report published on Tuesday, October 30, 2018 7:19:03 PM EDT

This is a summary of a home inspection performed on the property. It is recommended that the entire report be read.



Exterior and Foundation
1) Safety, Repair/Replace, Evaluate - One trip hazards were/were found in the driveway due to cracks, settlement and/or heaving. Recommend having a qualified contractor evaluate and repair or replace driveway sections as necessary to eliminate trip hazards.

Attic/Roof
11) Repair/Replace, Evaluate, Conducive conditions - Gaps were found in 1 roof surface seams. These may result in leaks. Recommend evaluation and repair/sealing as necessary.
12) Repair/Replace, Evaluate - The siding/trim on one exterior walls above lower roof sections was in contact with or had less than a one inch gap between it and the roof surface below. A gap is recommended so water isn't wicked up into the siding from the shingles below (important mainly if wood siding/trim is used). The gap is also to provide room for additional layers of roofing materials when the current roof surface fails. Consider improving.

deterioration found, recommend repair, rear upper
13) Repair/Replace, Evaluate - Damaged/lifted flashing at flat roof. Recommend evaluation and improvement by a qualified roofer.

Basement
51) Repair/Replace - The check valve was not working on the sump pump's discharge pipe. As a result of this water in the discharge pipe was flowing back down into the sump tank after the pump shuts off. Recommend replacing the check valve. For more information on sump pump installations, visit http://www.hometips.com/cs-protected/guides/sumps.html

Rear sump near furnace