View as PDF

View report

Habitation Investigation

https://www.homeinspectionsinohio.com
(614) 413-0075 · (937) 205-4758
Inspector: Laura Troth
Title picture

Summary
Unofficial version!

Client(s): New Build Client
Property address: Luxury New Build
Delaware OH 43015-9807
Inspection date: Tuesday, September 16, 2025

This report published on Thursday, October 16, 2025 1:12:14 PM EDT

This is a summary of the inspection performed on the property. It is recommended that the entire report be read.


Exterior and Foundation
8) Safety, Repair/Replace, Evaluate -  Exterior entry stairs were not secured in place. Recommend correction to prevent movement/falls.
Photo
Photo 8-1 
10) Repair/Replace -  Soffit vent screens are blocked by paint, insulation or debris. This can reduce air flow through the attic, reduce the life of the roof surface because of high temperatures, and/or increase the moisture content in the attic. Repairs should be made as necessary, such as cleaning paint from screens, replacing screens, and/or moving insulation so vents are unobstructed.

House and garages blocked by paint
Photo
Photo 10-1 
Photo
Photo 10-2 
Photo
Photo 10-3 
11) Repair/Replace -  The perimeter grading around the structure was relatively flat or sloped slightly down towards the home. Recommend grading soil so it slopes down and away from the structure. The grade should drop at least 6 inches within the first 10 feet.
https://homeinspectionsinohio.com/negative-grading/

It is common for newer homes to have settling of the exterior soil especially the first several years. Recommend monitoring and adding new soil as needed.
Photo
Photo 11-1 
Electric service and Branch Wiring
24) Safety, Repair/Replace, Evaluate -  Electrical wires were routed through duct work used for heating and cooling. This is not recommend due to the extra heat can lead to premature aging of insulation, vibrations can lead to abrasion of wire insulation. Recommend correction as needed.
Photo
Photo 24-1 
Heating and cooling
32) Repair/Replace, Evaluate -  One section of flex duct had inadequate support due to supports being spaced too far apart. Most manufacturers, and the Sheet Metal and Air Conditioning Contractors National Association (SMACNA) recommend that flex duct supports be spaced no farther apart than 5 feet. A qualified heating/cooling contractor should evaluate and repair as necessary.
Photo
Photo 32-1 
33) Repair/Replace -  Drywall dust, and construction debris such as sawdust usually accumulates in heating/cooling ducts during new construction and flips of properties. The drywall dust in particular can reduce the life of the furnace or air handler if left to circulate. Recommend having a qualified contractor clean the ducts.
Plumbing, Toilets, Water Heater
40) Safety, Repair/Replace, Evaluate -  Corrosion, scale or melted components were found on the water heater's burner and/or pilot assemblies and/or around the draft hood. This may be caused by condensation in the exhaust flue due to improper drafting and/or continuous use due to the water heater being undersized. A qualified contractor should evaluate and repair or replace the water heater as necessary.
Photo
Photo 40-1 
42) Repair/Replace, Evaluate -  Cold water did not flow at the master tub, only warm to hot water flowed. This is likely due to the mixing valve. A plumber should evaluate and make corrections so both hot and cold water flows.
Photo
Photo 42-1 
43) Repair/Replace -  Master bathroom tub was not secured in place. Recommend correction to prevent movement which can lead to leaks.
Photo
Photo 43-1 
Basement
61) Repair/Replace, Evaluate, Monitor -  Evidence of prior water intrusion was found in at least one section of the basement. For example, water stains and/or efflorescence on the foundation or floor, water stains at bases of support posts, etc. Accumulated water is a conducive condition for wood destroying insects and organisms and should not be present in the basement. The client(s) should review any disclosure statements available and ask the property owner(s) about past accumulation of water in the basement. The inspector is unable to determine how much water may enter in the future. The basement should be monitored in the future for accumulated water, especially after heavy and/or prolonged periods of rain. If water is found to accumulate, a qualified contractor who specializes in drainage issues should evaluate and repair as necessary. Typical repairs for preventing water from accumulating in the basement include:
  • Repairing, installing or improving rain run-off systems (gutters, downspouts and extensions or drain lines)
  • Improving perimeter grading
  • Repairing, installing or improving underground footing and/or curtain drains

Ideally, water should not enter the basement, but if water must be controlled after it enters the basement, then typical repairs include installing sump pump(s) or interior perimeter drains.
Photo
Photo 61-1 
Photo
Photo 61-2 
Garage
74) Safety, Repair/Replace, Evaluate -  Wall and/or ceiling surfaces between the attached garage and interior living spaces had gaps, holes, or missing or inadequate surface materials. These surfaces are intended to prevent vehicle fumes from entering living spaces, and to slow the spread of fire from the garage to living spaces and spaces above those areas. Recommend evaluation and repairs as necessary so the attached garage wall and ceiling surfaces that adjoin living spaces are tightly sealed and fire rated as per standard building practices. Typically these surfaces require a one-hour fire rating.

Fire-rated spray foam is an easy way to seal small gaps
Photo
Photo 74-1 
Attic/Roof
82) Repair/Replace, Evaluate -  Shingles were damaged, deteriorated and/or missing in area(s). Recommend evaluation by a roofer and replacement of any shingles in need to help prevent leaks.
Photo
Photo 82-1 
Photo
Photo 82-2