Summary

Client(s):  Kevin McConnell
Property address:  10200 Beach Club Dr Unit 8D
Myrtle Beach, SC 29572
Inspection date:  Monday, August 4, 2025

This report published on Tuesday, August 5, 2025 1:28:59 PM EDT

This report is the exclusive property of this inspection company and the client listed in the report title. Use of this report by any unauthorized persons is prohibited unless otherwise directed by client. This is a general document. This section is not the full report. It is recommended that you read and review entire report above. Below is a list of the items that were found on the day of inspection at listed address.

Concerns are shown and sorted according to these types:
Concern typeSafetyPoses a safety hazard
Concern typeRepair/ReplaceRecommend repairing or replacing
Concern typeRepair/MaintainRecommend repair and/or maintenance
Concern typeEvaluateRecommend evaluation by a specialist
Concern typeCommentFor your information


Exterior
4) Guardrails had gaps that were too large. This poses a safety hazard for children (e.g. falling, getting stuck in railing). Guardrails should not have gaps or voids that allow passage of a sphere equal to or greater than 4 inches in diameter. At a minimum, the Client should be aware of this hazard. Recommend that a qualified contractor repair or replace guardrails per standard building practices.
Photo
Photo 4-1 
Photo
Photo 4-2 
Photo
Photo 4-3 
5) Holes were observed in ceiling at rear balcony. Holes were observed at front exterior door frame. Recommend a qualified person evaluate and repair as necessary.
Photo
Photo 5-1 
Photo
Photo 5-2 
Photo
Photo 5-3 

Electric
6) Electric receptacles at the kitchen and bathrooms had no visible ground fault circuit interrupter (GFCI) protection. If not GFCI-protected, receptacles in wet areas pose a shock hazard. Recommend that a qualified electrician evaluate and install GFCI protection as necessary and per standard building practices.
Photo
Photo 6-1 
Photo
Photo 6-2 
Photo
Photo 6-3 
Photo
Photo 6-4 
Photo
Photo 6-5 
Photo
Photo 6-6 
Photo
Photo 6-7 
7) Panel is located in hallway closet, closets are not an approved location for electrical panels. Panel has inadequate working space. This is a safety hazard when opening or working in panels. Recommend that a qualified electrician evaluate and repair or make modifications per standard building practices.
Photo
Photo 7-1 
8) Wiring was exposed in mechanical closet and was subject to damage. Wiring was exposed under kItchen sink and at water heater and is subject to damage. The insulation can be damaged by objects coming in contact with it, resulting in exposed, energized wires. Also, copper conductors can break after being repeatedly moved or bent. This is a potential shock or fire hazard. Recommend that a qualified electrician repair per standard building practices.
Photo
Photo 8-1 
Photo
Photo 8-2 
9) One or more electric receptacles/ the boxes in which they were installed were loose/ not securely anchored. Wire conductors can be damaged due to repeated movement and/or tension on wires, or insulation can be damaged. This is a shock and fire hazard. Recommend that a qualified electrician repair as necessary.
Photo
Photo 9-1 Entry hallway
Photo
Photo 9-2 Living room, right side
Photo
Photo 9-3 Kitchen, beside refrigerator
Photo
Photo 9-4 Kitchen
Photo
Photo 9-5 Kitchen sink, junction box
10) One smoke alarm was observed in the condo. According to its product tag it is 2015. It is recommended to replace smoke alarms every 10 years. No smoke alarms were installed in the bedrooms. Smoke alarms should be installed as necessary so a functioning alarm exists in each hallway leading to bedrooms, in each bedroom and on each level. Recommend installing smoke alarms.
Photo
Photo 10-1 
11) Branch circuit wiring installed in buildings built prior to the mid 1980s is typically rated for a maximum temperature of only 60 degrees Celsius. Newer electric fixtures including lighting and fans typically require wiring rated for 90 degrees Celsius. Connecting newer fixtures to older, 60-degree-rated wiring is a potential fire hazard. Repairs for such conditions may involve replacing the last few feet of wiring to newer fixtures with new 90-degree-rated wire, and installing a junction box to join the old and new wiring.

It is beyond the scope of this inspection to determine if such incompatible components are installed, or to determine the extent to which they're installed. Based on the age of this building, the client should be aware of this safety hazard, both for existing fixtures and when planning to upgrade with newer fixtures. Consult with a qualified electrician for repairs as necessary.
12) The ceiling fan in Kitchen appears to have constant power. Inspector did not observe switch to operate fixture. Recommend a qualified electrician evaluate and repair as necessary.
Photo
Photo 12-1 
13) Wiring had substandard installation in living room and front bedroom closet. Client may wish to have this repaired.
Photo
Photo 13-1 
Photo
Photo 13-2 

Plumbing
15) Corrosion was found at water supply under Kitchen sink. Stains were found at drain pipe connection under Kitchen sink. Leaks can and are likely to occur as a result. Recommend that a qualified plumber evaluate and replace components as necessary.
Photo
Photo 15-1 
Photo
Photo 15-2 
16) Substandard drain pipe connection was observed at master bathroom sink. Accordian style drain pipes are known to easily collect debris and not drain properly. Recommend that a qualified plumber evaluate and replace as necessary.
Photo
Photo 16-1 
17) The expansion valve drain line, overflow pan drain line and condensation drain line from Air handler terminate above cover in floor at mechanical closet. Staining and damaged wall covering was observed at this area. Microbial growth was observed at area. Its is beyond the scope of inspection to determine which staining/ substance this is. Stains, damaged trim was observed around mechanical closet door and had elevated levels of moisture at time of inspection. Recommend a qualified person evaluate and make repairs as necessary.
Photo
Photo 17-1 
Photo
Photo 17-2 
Photo
Photo 17-3 
Photo
Photo 17-4 
Photo
Photo 17-5 
Photo
Photo 17-6 
Photo
Photo 17-7 

Water Heater
19) The hot water temperature was greater than 120 degrees Fahrenheit. This is a safety hazard due to the risk of scalding. The thermostat should be adjusted so the water temperature doesn't exceed 120 degrees.
Photo
Photo 19-1 

Heating, Ventilation and Air Condition (HVAC)
21) Insulation was missing at area of refrigerant line. No insulation was installed on P-trap at air handler or drain line, microbial staining was observed on drain line. It is beyond scope of inspection to determine which type of staining this is. Recommend a qualified person repair/replace insulation as necessary, evaluate and repair/clean drain line as necessary.
Photo
Photo 21-1 
22) A/C was set to 70 degrees Fahrenheit. Temperature output was 51 degrees Fahrenheit. Cooling system output appears to be working properly. However, the temperature reading at thermostat did not match the measured return air (return air was measured at 66 degrees Fahrenheit, temperature reading on thermostat was 73 degrees Fahrenheit). Recommend a qualified HVAC technician evaluate and repair thermostat as necessary.
Photo
Photo 22-1 
Photo
Photo 22-2 
Photo
Photo 22-3 
23) Thermostat wiring was substandard. Recommend a qualified HVAC technician evaluate and repair as necessary.
Photo
Photo 23-1 
24) Coils at air handler were dirty, had buildup. Recommend a qualified person clean as necessary.
Photo
Photo 24-1 

Kitchen
27) The range could tip forward. An anti-tip bracket may not be installed. This is a potential safety hazard since the range can tip forward when weight is applied to the open door, such as when a small child climbs on it or if heavy objects are dropped on it. Anti-tip brackets have been sold with all free-standing ranges since 1985. Recommend installing an anti-tip bracket to eliminate this safety hazard.
28) Stains, some microbial were found in the cabinet below the sink. Plumbing leaks may have occurred in the past. It is beyond scope of inspection to determine what type of staining this is. Recommend a qualified person evaluate and repair as necessary.
Photo
Photo 28-1 
Photo
Photo 28-2 
29) The bottom hinge at cabinet door at lazy susan cabinet was loose. Recommend that a qualified person repair as necessary.
Photo
Photo 29-1 
30) The vent at microwave was loose, held in place with cardboard material. Recommend a qualified person repair as necessary.
Photo
Photo 30-1 

Bathrooms
33) Gaps were observed around plumbing lines in both bathrooms where ran through cabinets/walls. Cabinet was cutout at master bathroom sink. Recommend a qualified person repair/ seal as necessary.
Photo
Photo 33-1 
Photo
Photo 33-2 
34) The toilet at hallway bathroom was loose where it attached to the floor. Leaks can occur. Flooring, the sub-floor or areas below may get damaged. Sewer gases can enter living spaces. Recommend that a qualified contractor repair as necessary. Caulk was missing around the base of the toilets at both bathrooms. Modern standards require caulk to be installed around the entire toilet base where it meets the floor for sanitary reasons. Recommend that a qualified person caulk around toilet base per standard building practices.
Photo
Photo 34-1 
Photo
Photo 34-2 
35) Caulk was missing around the base of the bathtub spout at hallway bathroom. Water may enter the wall structure behind the bathtub. Recommend that a qualified person repair as necessary to eliminate the gap.
Photo
Photo 35-1 
36) Grout was cracked in area around bathtub and tile junction. Grout is likely to crack as it will not adhere to bathtub material. Water may enter the wall structure behind the bathtub. Recommend replacing grout with caulk.
Photo
Photo 36-1 

Interior, Doors and Windows
37) One or more doors stick in door jamb when opening/closing. Hallway closet bi-fold door bind in jamb, won't fully close. Recommend a qualified person repair/adjust doors as necessary.
Photo
Photo 37-1 Front exterior door
Photo
Photo 37-2 Front bedroom entry door from hallway
Photo
Photo 37-3 Front bedroom entry door
Photo
Photo 37-4 Hallway closet bi-fold door
38) Master bedroom closet door wouldn't latch when closed. Recommend a qualified person repair as necessary.
Photo
Photo 38-1 
39) The sliding screen doors at living room are difficult to slide. Screen is deteriorated in area. Weatherstripping/seal is loose on left side sliding glass door. Recommend a qualified person repair as necessary.
Photo
Photo 39-1 
Photo
Photo 39-2 
Photo
Photo 39-3 
40) The lock at living room sliding glass door is difficult to operate. Recommend that a qualified person repair as necessary.
Photo
Photo 40-1 
41) One or more windows wouldn't open (windows noted: Kitchen, front bedroom left window, two end windows at master bedroom). Middle window at master bedroom was difficult to open/close. Release tabs at windows were caulked over in areas. Recommend that a qualified person repair windows as necessary so they open and close easily. Note, exterior or windows where visible had deteriorated paint/coating.
Photo
Photo 41-1 Kitchen window, wouldn't open
Photo
Photo 41-2 Front bedroom, left window wouldn't open
Photo
Photo 41-3 Master bedroom, two end windows wouldn't open. Middle window was difficult to open/close
Photo
Photo 41-4 
Photo
Photo 41-5 
Photo
Photo 41-6 
42) The lock at hallway bathroom door is inoperable (doesn't lock). Recommend a qualified person repair as necessary.
43) Bubbled drywall was observed beside front exterior door. Slightly elevated level of moisture was observed at time of inspection. Recommend a qualified person evaluate further.
Photo
Photo 43-1 
Photo
Photo 43-2