This report published on Thursday, June 26, 2025 1:25:59 PM PDT
This report is the exclusive property of Ground Up Inspection Service L.L.C and the client(s) listed in the report title. Use of this report by any unauthorized persons is prohibited.
How to Read this Report
This report is organized by the property's functional areas. Within each functional area, descriptive information is listed first and is shown in bold type. Items of concern follow descriptive information.
Concerns are shown and sorted according to these types:
Safety
Poses a safety hazard
Repair/Replace
Recommend repairing or replacing
Repair/Maintain
Recommend repair and/or maintenance
Maintain
Recommend ongoing maintenance
Evaluate
Recommend evaluation by a specialist
Comment
For your information
Click here for a glossary of building construction terms.Contact your inspector If there are terms that you do not understand, or visit the glossary of construction terms at https://www.reporthost.com/glossary.asp
Client present for discussion at end of inspection: Yes
Weather conditions during inspection: Dry (no rain)
Temperature during inspection: Warm
Ground condition: Dry
Recent weather: Dry (no rain)
Overnight temperature: Cool
Payment method: Credit card
Type of building: Single family
Buildings inspected: One house
Number of residential units inspected: 1
Age of main building: 1990
Source for main building age: Municipal records or property listing
Occupied: Yes, Furniture or stored items were present
1) Repair/Replace, Evaluate - Evidence of rodent infestation was found in the form of feces and damaged/soiled insulation in the attic and crawl space. Consult with the condo association about this. A qualified pest controller and/or contractor should make repairs to seal openings in the structure, set traps, and clean rodent waste as necessary. For sanitary reasons, all insulation should be replaced.
Photo 1-1 Photo 1-2
Photo 1-3 Photo 1-4
2) Comment - Some areas and items at this property were obscured by furniture and/or stored items. This often includes but is not limited to walls, floors, windows, inside and under cabinets, under sinks, on counter tops, in closets, behind window coverings, under rugs or carpets, and under or behind furniture. Areas around the exterior, under the structure, in the garage and in the attic may also be obscured by stored items. The inspector in general does not move personal belongings, furnishings, carpets or appliances. When furnishings, stored items or debris are present, all areas or items that are obscured, concealed or not readily accessible are excluded from the inspection. The client should be aware that when furnishings, stored items or debris are eventually moved, damage or problems that were not noted during the inspection may be found.
Limitations: Unless specifically included in the inspection, the following items and any related equipment, controls, electric systems and/or plumbing systems are excluded from this inspection: detached buildings or structures; fences and gates; retaining walls; underground drainage systems, catch basins or concealed sump pumps; swimming pools and related safety equipment, spas, hot tubs or saunas; whether deck, balcony and/or stair membranes are watertight; trees, landscaping, properties of soil, soil stability, erosion and erosion control; ponds, water features, irrigation or yard sprinkler systems; sport courts, playground, recreation or leisure equipment; areas below the exterior structures with less than 3 feet of vertical clearance; invisible fencing; sea walls, docks and boathouses; retractable awnings. Any comments made regarding these items are as a courtesy only.
Site profile: Level
Condition of driveway: Minor deterioration
Condition of sidewalks and/or patios: No defects noted at time of inspection
Sidewalk material: Poured in place concrete
Condition of decks, porches and/or balconies: Required repairs, replacement and/or evaluation (see comments below)
Deck, porch and/or balcony material: Wood
3) Repair/Replace, Evaluate - Rot was found in many of the decking boards. Recommend that a qualified contractor further evaluate and replace decking as necessary.
Limitations: The inspector performs a visual inspection of accessible components or systems at the exterior. Items excluded from this inspection include below-grade foundation walls and footings; foundations, exterior surfaces or components obscured by vegetation, stored items or debris; wall structures obscured by coverings such as siding or trim. Some items such as siding, trim, soffits, vents and windows are often high off the ground, and may be viewed using binoculars from the ground or from a ladder. This may limit a full evaluation. Regarding foundations, some amount of cracking is normal in concrete slabs and foundation walls due to shrinkage and drying. Note that the inspector does not determine the adequacy of seismic reinforcement.
Condition of wall exterior covering: No defects noted at time of inspection
Apparent wall structure: Wood frame
Wall covering: Wood
Condition of foundation and footings: No defects noted at time of inspection
Apparent foundation type: Crawl space
Foundation/stem wall material: Poured in place concrete
Footing material (under foundation stem wall): Poured in place concrete
Anchor bolts or hold downs for seismic reinforcement: Installed
Limitations: The following items or areas are not included in this inspection: areas that could not be traversed or viewed clearly due to lack of access; solar roofing components. Any comments made regarding these items are made as a courtesy only. Note that the inspector does not provide an estimate of remaining life on the roof surface material, nor guarantee that leaks have not occurred in the roof surface, skylights or roof penetrations in the past. Regarding roof leaks, only active leaks, visible evidence of possible sources of leaks, and evidence of past leaks observed during the inspection are reported on as part of this inspection. The inspector does not guarantee or warrant that leaks will not occur in the future. Complete access to all roof and attic spaces during all seasons and during prolonged periods of all types of weather conditions (e.g. high wind and rain, melting snow) would be needed to do so. Regarding the roof drainage system, unless the inspection was conducted during and after prolonged periods of heavy rain, the inspector was unable to determine if gutters, downspouts and extensions performed adequately or were leak-free.
Roof inspection method: Traversed
Condition of roof surface material: Appeared serviceable
Roof surface material: Asphalt or fiberglass composition shingles
Roof type: Hipped
Apparent number of layers of roof surface material: One
Condition of exposed flashings: No visual defects noted at time of inspection
Condition of gutters, downspouts and extensions: No defects noted at time of inspection, Limited evaluation due to little or no rainfall during and prior to the inspection
Gutter and downspout installation: Full
4) Repair/Replace, Evaluate - Ridge and hip shingles were worn and deteriorated. Damage from wind and rain may occur in the future. Recommend consulting with the association about this and that a qualified contractor replace ridge and hip shingles as necessary.
Photo 4-1 Photo 4-2
Photo 4-3
5) Maintain - Minor amounts of moss was growing on the roof. As a result, shingles can lift or be damaged. Leaks can result and/or the roof surface can fail prematurely. Efforts should be made to kill the moss during its growing season (wet months). Typically, zinc or phosphate-based chemicals are used for this and must be applied periodically.
Limitations: The following items are not included in this inspection: household appliances such as stoves, ovens, cook tops, ranges, warming ovens, griddles, broilers, dishwashers, trash compactors, refrigerators, freezers, ice makers, hot water dispensers and water filters; appliance timers, clocks, cook functions, self and/or continuous cleaning operations, thermostat or temperature control accuracy, and lights. Any comments made regarding these items are as a courtesy only. Note that the inspector does not provide an estimate of the remaining life of appliances, and does not determine the adequacy of operation of appliances. The inspector does not note appliance manufacturers, models or serial numbers and does not determine if appliances are subject to recalls. Areas and components behind and obscured by appliances (such as the refrigerator) are inaccessible and excluded from this inspection. The inspector does make every attempt to adequately operate and report the findings of these items when applicable.
Limitations: The following items are not included in this inspection: overflow drains for tubs and sinks; heated towel racks, saunas, steam generators, clothes washers, clothes dryers. Any comments made regarding these items are as a courtesy only. Note that the inspector does not determine the adequacy of washing machine drain lines, washing machine catch pan drain lines, or clothes dryer exhaust ducts. The inspector does not operate water supply or shut-off valves for sinks, toilets, bidets, clothes washers, etc. due to the possibility of valves leaking or breaking when operated. The inspector does not determine if shower pans or tub and shower enclosures are water tight, or determine the completeness or operability of any gas piping to laundry appliances.
Location #1: 3/4 bath, first floor
Location #2: Full bath, Primary
Condition of counters: Shows normal signs of wear and blemishes for age
Condition of cabinets: Shows normal signs of wear and blemishes for age
Condition of flooring: Floors show signs of normal wear and tear, replacement or refinishing may be desired
Condition of sinks and related plumbing: Required repair, replacement and/or evaluation (see comments below)
Condition of toilets: No defects noted at time of inspection
Condition of bathtubs and related plumbing: No defects noted at time of inspection
Condition of shower(s) and related plumbing: No visual defects noted at time of inspection
Condition of ventilation systems: No defects noted at time of inspection
Bathroom and laundry ventilation type: Spot exhaust fans, with individual ducts
240 volt receptacle for laundry equipment present: Yes
7) Repair/Maintain - The sink drains was leaking at the main floor 3/4 bath. A qualified person should repair as necessary.
Photo 7-1
8) Comment - The jet tub was operable at the time of inspection.
Limitations: The following items are not included in this inspection: security, intercom and sound systems; communications wiring; central vacuum systems; elevators and stair lifts; cosmetic deficiencies such as nail-pops, scuff marks, dents, dings, blemishes or issues due to normal wear and tear in wall, floor and ceiling surfaces and coverings, or in equipment; deficiencies relating to interior decorating; low voltage and gas lighting systems. Any comments made regarding these items are as a courtesy only. Note that the inspector does not evaluate any areas or items which require moving stored items, furnishings, debris, equipment, floor coverings, insulation or similar materials. The inspector does not test for asbestos, lead, radon, mold, hazardous waste, urea formaldehyde urethane, or any other toxic substance. Some items such as window, drawer, cabinet door or closet door operability are tested on a sampled basis. The client should be aware that paint may obscure wall and ceiling defects, floor coverings may obscure floor defects, and furnishings may obscure wall, floor and floor covering defects. If furnishings were present during the inspection, recommend a full evaluation of walls, floors and ceilings that were previously obscured when possible. Determining the cause and/or source of odors is not within the scope of this inspection.
Condition of exterior entry doors: No visual defects noted at time of inspection
Condition of interior doors: No defects noted at time of inspection
Condition of windows and skylights: Required repair, replacement and/or evaluation (see comments below)
Type(s) of windows: Vinyl, Wood, Multi-pane
Condition of walls and ceilings: Minor damage and/or deterioration (cracks/nail pops/blemishes)
Wall type or covering: Drywall, Paneling
Ceiling type or covering: Drywall
Condition of flooring: Floors show signs of normal wear and tear, replacement or refinishing may be desired
Flooring type or covering: Carpet, Laminate
Condition of stairs, handrails and guardrails: No defects noted at time of inspection
9) Repair/Replace, Evaluate - Staining was visible between multi-pane glass in four upper windows. This usually indicates that the seal between the panes of glass has failed or that the desiccant material that absorbs moisture is saturated. As a result, the view through the window may be obscured, the window's R-value will be reduced, and accumulated condensation may leak into the wall structure below. Recommend that a qualified contractor evaluate and repair windows as necessary. Usually, this means replacing the glass in window frames.
Be aware that evidence of failed seals or desiccant may be more or less visible depending on the temperature, humidity, sunlight, etc. Windows or glass-paneled doors other than those that the inspector identified may also have failed seals and need glass replaced. It is beyond the scope of this inspection to identify every window with failed seals or desiccant.
Photo 9-1
10) Repair/Maintain - The main floor front bedroom interior door was rubbing on the carpet. Recommend that a qualified person adjust hardware or trim the door as necessary.
Limitations: The inspector does not determine the adequacy of firewall ratings. Requirements for ventilation in garages vary between municipalities.
Type: Attached
Condition of exterior entry doors: No visual defects noted at time of inspection
Condition of garage vehicle door(s): No defects noted at time of inspection
Type of garage vehicle door: Sectional
Number of vehicle doors: 1
Condition of automatic opener(s): No defects noted at time of inspection
Condition of garage floor: minor damage (cracks)
Condition of garage interior: Required repair or evaluation (see comments below)
11) Safety, Repair/Replace - A hole was found in the attached garage wall below the electrical panel. Current standard building practices call for wooden-framed ceilings and walls that divide the house and garage to provide limited fire-resistance rating to prevent the spread of fire from the garage to the house. Recommend that a qualified person repair per standard building practices. For example, by patching openings or holes, firestopping holes or gaps with fire-resistant caulking, and/or installing fire-resistant wall covering (e.g. Type X drywall).
Photo 11-1
12) Safety, Repair/Maintain - No photoelectric sensors were installed for the garage vehicle doors' automatic opener. These have been required on all automatic door openers since 1993 and improve safety by triggering the door's auto-reverse feature without need for the door to come in contact with the object, person or animal that is preventing the door from closing. Recommend that a qualified contractor install photoelectric sensors where missing for improved safety.
Photo 12-1
13) Comment - Minor cracks were found in the concrete slab floor. These are common and appeared to be only a cosmetic issue.
Limitations: The following items are not included in this inspection: generator systems, transfer switches, surge suppressors, inaccessible or concealed wiring; underground utilities and systems; low-voltage lighting or lighting on timers or sensors. Any comments made regarding these items are as a courtesy only. Note that the inspector does not determine the adequacy of grounding or bonding, if this system has an adequate capacity for the client's specific or anticipated needs, or if this system has any reserve capacity for additions or expansion. The inspector does not operate circuit breakers as part of the inspection, and does not install or change light bulbs. The inspector does not evaluate every wall switch or receptacle, but instead tests a representative number of them per various standards of practice. When furnishings, stored items or child-protective caps are present some receptacles are usually inaccessible and are not tested; these are excluded from this inspection. Receptacles that are not of standard 110 volt configuration, including 240-volt dryer receptacles, are not tested and are excluded. The functionality of, power source for and placement of smoke and carbon monoxide alarms is not determined as part of this inspection. Upon taking occupancy, proper operating and placement of smoke and carbon monoxide alarms should be verified and batteries should be changed. These devices have a limited lifespan and should be replaced every 10 years. The inspector attempts to locate and evaluate all main and sub-panels. However, panels are often concealed. If panels are found after the inspection, a qualified electrician should evaluate and repair if necessary. The inspector attempts to determine the overall electrical service size, but such estimates are not guaranteed because the overall capacity may be diminished by lesser-rated components in the system. Any repairs recommended should be made by a licensed electrician.
Electric service condition: No defects noted at time of inspection
Primary service type: Underground
Service voltage (volts): 120-240
Primary service overload protection type: Circuit breakers
System ground: Ground rod(s) in soil
Condition of main service panel: No visual defects noted at time of inspection
Location of main service panel #A: Garage
Condition of branch circuit wiring: Required repair, replacement and/or evaluation (see comments below)
Carbon monoxide alarms installed: No, recommend install
14) Safety, Repair/Replace - Smoke alarms were missing from bedrooms. Additional smoke alarms should be installed as necessary.
15) Safety, Repair/Maintain - Based on the age of this structure and the appearance of existing smoke alarms, the alarms may have been installed more than 10 years ago. According to National Fire Protection Association, aging smoke alarms don't operate as efficiently and often are the source for nuisance alarms. Older smoke alarms are estimated to have a 30% probability of failure within the first 10 years. Newer smoke alarms do better, but should be replaced after 10 years. Unless you know that the smoke alarms are new, replacing them when moving into a new residence is also recommended by NFPA.
Photo 15-1
16) Safety, Repair/Maintain - The primary bathroom GFCI receptacle tested with an open ground circuit. This is a potential shock hazard. Recommend that a qualified electrician evaluate and repair as necessary.
Photo 16-1 Photo 16-2
17) Evaluate - The ceiling fan light fixtures were inoperable (didn't turn on when nearby switches were operated). Recommend further evaluation by replacing bulbs and/or consulting with the property owner. If replacing bulbs doesn't work and/or no other switch(es) can be found, then recommend that a qualified electrician evaluate and repair or replace light fixtures as necessary.
Limitations: The following items are not included in this inspection: private/shared wells and related equipment; private sewage disposal systems; hot tubs or spas; main, side and lateral sewer lines; gray water systems; pressure boosting systems; trap primers; incinerating or composting toilets; fire suppression systems; water softeners, conditioners or filtering systems; plumbing components concealed within the foundation or building structure, or in inaccessible areas such as below tubs; underground utilities and systems; overflow drains for tubs and sinks; backflow prevention devices. Any comments made regarding these items are as a courtesy only. Note that the inspector does not operate water supply or shut-off valves due to the possibility of valves leaking or breaking when operated. The inspector does not test for lead in the water supply, the water pipes or solder, does not determine if plumbing and fuel lines are adequately sized, and does not determine the existence or condition of underground or above-ground fuel tanks.
Condition of service and main line: No defects noted at time of inspection
Water service: Public
Location of main water shut-off: Not determined (obscured, inaccessible or none found)
Service pipe material: Copper
Condition of supply lines: No defects noted at time of inspection
Supply pipe material: Copper
Condition of drain pipes: No defects noted at time of inspection
Drain pipe material: Plastic
Condition of waste lines: Appeared serviceable
Waste pipe material: Plastic
Location(s) of plumbing clean-outs: Building exterior
Vent pipe condition: No defects noted at time of inspection
Vent pipe material: Plastic
Sump pump installed: None visible
Sewage ejector pump installed: None visible
Condition of fuel system: No defects noted at time of inspection
Visible fuel storage systems: None visible
Location of main fuel shut-off valve: At gas meter
Limitations: Evaluation of and determining the adequacy or completeness of the following items are not included in this inspection: water recirculation pumps; solar water heating systems; Energy Smart or energy saver controls; catch pan drains. Any comments made regarding these items are as a courtesy only. Note that the inspector does not provide an estimate of remaining life on water heaters, does not determine if water heaters are appropriately sized, or perform any evaluations that require a pilot light to be lit or a shut-off valve to be operated.
Condition of water heater: No visual defects noted at time of inspection
Limitations: The following items are not included in this inspection: humidifiers, dehumidifiers, electronic air filters; solar, coal or wood-fired heat systems; thermostat or temperature control accuracy and timed functions; heating components concealed within the building structure or in inaccessible areas; underground utilities and systems; safety devices and controls (due to automatic operation). Any comments made regarding these items are as a courtesy only. Note that the inspector does not provide an estimate of remaining life on heating or cooling system components, does not determine if heating or cooling systems are appropriately sized, does not test coolant pressure, or perform any evaluations that require a pilot light to be lit, a shut-off valve to be operated, a circuit breaker to be turned "on" or a serviceman's or oil emergency switch to be operated. It is beyond the scope of this inspection to determine if furnace heat exchangers are intact and free of leaks. Condensation pans and drain lines may clog or leak at any time and should be monitored while in operation in the future. Where buildings contain furnishings or stored items, the inspector may not be able to verify that a heat source is present in all "liveable" rooms (e.g. bedrooms, kitchens and living/dining rooms).
General heating system type(s): Forced air, Furnace
General heating distribution type(s): Ducts and registers
Last service date of primary heat source: 9-2024
Source for last service date of primary heat source: Label
Condition of forced air heating/(cooling) system: No defects noted at time of inspection
Forced air heating system fuel type: Natural gas
Estimated age of forced air furnace: 2012
Forced air heating system manufacturer: Lennox
Forced air furnace model #: G60DF-36A-070X-10
Forced air furnace serial number: 5912D00794
Location of forced air furnace: Mechanical room
Forced air system capacity in BTUs or kilowatts: 66,000 BTU
Condition of furnace filters: Appeared serviceable
Condition of forced air ducts and registers: No defects noted at time of inspection
19) Maintain - The gas-fired forced air furnace appeared to have been serviced within the last year based on labeling on the equipment. If this is true, then routine servicing is not needed at this point. However, a qualified HVAC contractor should inspect, clean, and service this system, and make repairs if necessary annually in the future.
Limitations: The following items are not included in this inspection: coal stoves, gas logs, chimney flues (except where visible). Any comments made regarding these items are as a courtesy only. Note that the inspector does not determine the adequacy of drafting or sizing in fireplace and stove flues, and also does not determine if prefabricated or zero-clearance fireplaces are installed in accordance with the manufacturer's specifications. The inspector does not perform any evaluations that require a pilot light to be lit, and does not light fires. The inspector provides a basic visual examination of a chimney and any associated wood burning device. The National Fire Protection Association has stated that an in-depth Level 2 chimney inspection should be part of every sale or transfer of property with a wood-burning device. Such an inspection may reveal defects that are not apparent to the home inspector who is a generalist.
Condition of gas-fired fireplaces or stoves: No defects noted at time of inspection
Gas fireplace or stove type: Metal pre-fab fireplace
Fan or blower installed in gas-fired fireplace or stove: Yes
Condition of chimneys and flues: No defects noted at time of inspection
Gas-fired flue type: B-vent
20) Safety, Maintain, Evaluate - Recommend that the client review all available documentation for the gas-fired fireplace and become familiar with the lighting and operating procedures. Depending on how it is operated (for routine heating versus ambiance), such appliance may need servicing annually or every few years. Consult with the property owner about past service history. If the last service has been more than one year of if unknown, recommend that a qualified HVAC technician service now and as needed in the future.
Limitations: The following items or areas are not included in this inspection: areas that could not be traversed or viewed clearly due to lack of access; areas and components obscured by insulation. Any comments made regarding these items are made as a courtesy only. The inspector does not determine the adequacy of the attic ventilation system. Complete access to all roof and attic spaces during all seasons and during prolonged periods of all types of weather conditions (e.g. high/low temperatures, high/low humidity, high wind and rain, melting snow) would be needed to do so. The inspector is not a licensed engineer and does not determine the adequacy of roof structure components such as trusses, rafters or ceiling beams, or their spacing or sizing.
Attic inspection method: Viewed from hatch(es)
Location of attic access point #A: Hall closet, Wall
Location of attic access point #B: second floor
Location of attic access point #C: Garage
Attic access points that were opened and viewed, traversed or partially traversed: A, B, C
Condition of roof structure: No defects noted at time of inspection
Roof structure type: Trusses
Ceiling structure: Trusses
Condition of insulation in attic (ceiling, skylight chase, etc.): Insulation was damaged, apparently by rodents
Ceiling insulation material: Fiberglass loose fill, Fiberglass roll or batt
Approximate attic insulation R value (may vary in areas): R-38
Condition of roof ventilation: No defects noted at time of inspection
Limitations: Structural components such as joists and beams, and other components such as piping, wiring and/or ducting that are obscured by under-floor insulation are excluded from this inspection. The inspector does not determine if support posts, columns, beams, joists, studs, trusses, etc. are of adequate size, spanning or spacing.
The inspector does not guarantee or warrant that water will not accumulate in the crawl spaces in the future. Complete access to all crawl space areas during all seasons and during prolonged periods of all types of weather conditions (e.g. heavy rain, melting snow) would be needed to do so.
The inspector attempts to locate all crawl space access points and areas. Access points may be obscured or otherwise hidden by furnishings or stored items. In such cases, the client should ask the property owner where all access points are that are not described in this inspection, and have those areas inspected. Note that crawl space areas should be checked at least annually for water intrusion, plumbing leaks and pest activity.
Crawl space inspection method: Traversed
Location of crawl space access point #A: Building exterior
Condition of floor substructure above: No visual defects noted at time of inspection
Pier or support post material: Wood
Beam material: Solid wood
Floor structure above: Solid wood joists
Condition of insulation underneath floor above: Required repairs, replacement and/or evaluation (see comments below)
Insulation material underneath floor above: Fiberglass roll or batt
Condition of vapor barrier: No visual defects noted at time of inspection
Vapor barrier present: Yes, Full
Condition of crawl space ventilation: No visual defects noted at time of inspection
Ventilation type: with vents
22) Repair/Maintain - The crawl space access hatch door in the foundation wall fit poorly. Recommend that a qualified person repair as necessary to prevent rodent entry.
Photo 22-1
23) Comment - Many crawl space vents were intentionally blocked (e.g. removable panels, rigid foam). This restricts ventilation in the crawl space and can result in increased levels of moisture inside. This is a conducive condition for wood-destroying organisms. Such vents should be left open at all times except during severe freezing weather. Recommend removing materials blocking vents as necessary.
Photo 23-1
24) Comment - View of crawl space
Photo 24-1 Photo 24-2
Photo 24-3 Photo 24-4
Thank you for choosing Ground Up Inspection Service L.L.C. Please contact at any time with questions regarding your inspection report. Adam Morvee WA State Home Inspector #1266 360-927-1723 Adam@groundupinspection.com