777 Dog House Loop Apt 8 Coeur D Alene ID 83814-6199
Inspection date:
Wednesday, October 4, 2023
This report published on Wednesday, January 10, 2024 7:00:56 PM PST
Please understand that there are limitations to this inspection. Many components of the home are not visible during the inspection and very little historical information is provided in advance of the inspection. While we can reduce your risk of purchasing a home, we cannot eliminate it, nor can we assume it. Even the most comprehensive inspection cannot be expected to reveal every condition you may consider significant to ownership.
This report is organized by the property's functional areas. Within each functional area, descriptive information is listed first and is shown in bold type. Items of concern follow descriptive information.
Concerns are shown and sorted according to these types:
Safety
Poses a safety hazard
Repair Recommended
Item was not functioning as designed or intended. Correction should be performed, and may require a professional, specialist, or other knowledgeable person.
Maintenance Reminder
Recommend routine attention and maintenance to keep item in proper working condition.
Investigate Further
Recommend additional investigation, research, or review by a specialist and/or client
Informational Comment
Report comment included for your information and consideration.
Click here for a glossary of building construction terms.Contact your inspector If there are terms that you do not understand, or visit the glossary of construction terms at https://www.reporthost.com/glossary.asp
Client present for discussion at end of inspection: Yes
Inspector: Timber
Weather conditions during inspection: Sunny
Temperature during inspection: Warm
Sq. footage.: 2194
Type of building: Condo
Age of main building: 2010
Source for main building age: Municipal records or property listing
1) To view the summary. Click on the link in the upper left hand corner or under table contents.
2) The residential dwelling unit appeared to be part of a complex that is managed and maintained by a "Home Owners" or "Condo" association. This inspection is limited to a visual evaluation of the systems and components that are located within the dwelling unit inspected. The current condition of "Common Elements" are excluded from this inspection. Such elements include, but are not limited to:
The building site condition, structural stability, drainage systems and insulation
All exterior surfaces, materials and structure
All roof surfaces, materials and structure
All attic spaces
The building foundation, floor substructure and all spaces below, such as basements and/or crawl spaces
All stairs, landings, porches, hallways, walks and balconies, elevators, utility metering, parking stalls/ports
All decks, patios, pools, spas, recreational areas/equipment
All common areas on the property
Any comments regarding these items in this report have been made as a courtesy only. Consult with the Home Owner's or Condo Association regarding these items.
Limitations: Unless specifically included in the inspection, the following items and any related equipment, controls, electric systems and/or plumbing systems are excluded from this inspection: detached buildings or structures; fences and gates; retaining walls; underground drainage systems, catch basins or concealed sump pumps; swimming pools and related safety equipment, spas, hot tubs or saunas; whether deck, balcony and/or stair membranes are watertight; trees, landscaping, properties of soil, soil stability, erosion and erosion control; ponds, water features, irrigation or yard sprinkler systems; sport courts, playground, recreation or leisure equipment; areas below the exterior structures with less than 3 feet of vertical clearance; invisible fencing; sea walls, docks and boathouses; retractable awnings. Any comments made regarding these items are as a courtesy only.
Site profile: Minor slope
Driveway material: Asphalt
Sidewalk material: Poured in place concrete
Deck, patio, porch cover material and type: Covered (Refer to Roof section)
Deck, porch and/or balcony material: Waterproof coating or membrane
Limitations: The inspector performs a visual inspection of accessible components or systems at the exterior. Items excluded from this inspection include below-grade foundation walls and footings; foundations, exterior surfaces or components obscured by vegetation, stored items or debris; wall structures obscured by coverings such as siding or trim. This may limit a full evaluation. Regarding foundations, some amount of cracking is normal in concrete slabs and foundation walls due to shrinkage and drying. Note that the inspector does not determine the adequacy of seismic reinforcement.
Wall inspection method: Viewed from ground
Apparent wall structure: Wood frame
Wall covering: Cement fiber, Stone or faux stone veneer
Apparent foundation type: Concrete slab on grade
Foundation/stem wall material: Poured in place concrete
Limitations: The following items or areas are not included in this inspection: areas that could not be traversed or viewed clearly due to lack of access; areas and components obscured by insulation. Any comments made regarding these items are made as a courtesy only. Complete access to all roof and attic spaces during all seasons and during prolonged periods of all types of weather conditions (e.g. high/low temperatures, high/low humidity, high wind and rain, melting snow) would be needed to do so.
Attic inspection method: Traversed
Location of attic access point #A: Laundry room
Roof structure type: Trusses
roof material: Oriented strand board
Ceiling structure: Trusses
Ceiling insulation material: Fiberglass loose fill
Approximate attic insulation R value (may vary in areas): R-38
Limitations: The inspector does not operate circuit breakers as part of the inspection, and does not install or change light bulbs. The inspector does not evaluate every wall switch or receptacle, but instead tests a representative number of them per various standards of practice. When furnishings, stored items or child-protective caps are present some receptacles are usually inaccessible and are not tested; these are excluded from this inspection. Receptacles that are not of standard 110 volt configuration, including 240-volt dryer receptacles, are not tested and are excluded. The functionality of, power source for and placement of smoke and carbon monoxide alarms is not determined as part of this inspection. Upon taking occupancy, proper operating and placement of smoke and carbon monoxide alarms should be verified and batteries should be changed. These devices have a limited lifespan and should be replaced every 10 years. The inspector attempts to locate and evaluate all main and sub-panels. However, panels are often concealed. If panels are found after the inspection, a qualified electrician should evaluate and repair if necessary. The inspector attempts to determine the overall electrical service size, but such estimates are not guaranteed because the overall capacity may be diminished by lesser-rated components in the system. Any repairs recommended should be made by a licensed electrician.
Primary service type: Underground
Number of service conductors: 3
Service voltage (volts): 120-240
Estimated service amperage: 200
Primary service overload protection type: Circuit breakers
Service entrance conductor material: Stranded aluminum
Main disconnect rating (amps): 200
System ground: Copper, Not determined, not readily apparent
Location of main service panel #B: Laundry room
Location of main disconnect: Breaker at bottom of main service panel
6) The house does not meet current standards. Smoke alarms were over 10 years old.
Current safety standards recommend smoke alarms should be installed in each bedroom, in hallways leading to bedrooms, and on each level. They have a limited lifespan and should be replaced every 10 years. Batteries in smoke alarms should be changed when taking occupancy and annually in the future. Carbon monoxide alarms should be installed near sleeping areas and on each level in homes with a fuel-burning appliance or attached garage. For more information, visit: http://www.reporthost.com/?SMKALRM http://www.reporthost.com/?COALRM
Limitations: The following items are not included in this inspection: private/shared wells and related equipment; private sewage disposal systems; hot tubs or spas; main, side and lateral sewer lines; gray water systems; pressure boosting systems; trap primers; incinerating or composting toilets; fire suppression systems; water softeners, conditioners or filtering systems; plumbing components concealed within the foundation or building structure, or in inaccessible areas such as below tubs; underground utilities and systems; overflow drains for tubs and sinks; backflow prevention devices. Any comments made regarding these items are as a courtesy only. Note that the inspector does not operate water supply or shut-off valves due to the possibility of valves leaking or breaking when operated. The inspector does not test for lead in the water supply, the water pipes or solder, does not determine if plumbing and fuel lines are adequately sized, and does not determine the existence or condition of underground or above-ground fuel tanks.
Water service: Public
Location of main water meter: Not applicable (private or shared well)
Location of main water shut-off: Garage, In mechanical room
Service pipe material: Plastic
Supply pipe material: PEX plastic
Drain pipe material: Plastic
Waste pipe material: Plastic
Location(s) of plumbing clean-outs: Building exterior
Vent pipe material: Plastic
Location of main fuel shut-off valve: At gas meter
Location of main fuel shut-off valve: By furnace
8) One fire sprinkler heads was loose and needs to be secured or reset above the elevator. Recommend that a qualified person evaluate and repair as needed.
Photo 8-1 Photo 8-2
Photo 8-3 Photo 8-4
9) A fire suppression system was installed on the premises. These are specialty systems and are excluded from this inspection. Comments in this report related to this system are made as a courtesy only and are not meant to be a substitute for a full evaluation by a qualified specialist. These systems normally require periodic inspection by a specialist to ensure correct operation. For example, checking for possible backflow contamination of the potable water system, or correct operation of valves and gauges. Recommend that a qualified specialist inspect this system in accordance with National Fire Prevention Association (NFPA) 25 standards.
Photo 9-1 Photo 9-2
Photo 9-3 Photo 9-4
10) Water pressure taken at the house measured PSI. Typical residential water pressure is 40 to 80 PSI.
Photo 10-1
11) One sewer clean out was noted at the back of the condo.
Photo 11-1
12) Main water shutoff valve is located in the garage.
14) A circulating pump was installed for the hot water supply. It is intended to make hot water immediately available when faucets are turned on. Timers are typically integrated with these pumps, and should be configured so water circulates only at desired times for better energy efficiency. The client should familiarize themselves with the timer's operation and configure it as needed. The inspector did not determine if it was serviceable or operable.
Limitations: The following items are not included in this inspection: humidifiers, dehumidifiers, electronic air filters; solar, coal or wood-fired heat systems; thermostat or temperature control accuracy and timed functions; heating components concealed within the building structure or in inaccessible areas; underground utilities and systems; safety devices and controls (due to automatic operation). Any comments made regarding these items are as a courtesy only. Note that the inspector does not provide an estimate of remaining life on heating or cooling system components, does not determine if heating or cooling systems are appropriately sized, does not test coolant pressure, or perform any evaluations that require a pilot light to be lit, a shut-off valve to be operated, a circuit breaker to be turned "on" or a serviceman's or oil emergency switch to be operated. It is beyond the scope of this inspection to determine if furnace heat exchangers are intact and free of leaks. Condensation pans and drain lines may clog or leak at any time and should be monitored while in operation in the future. Where buildings contain furnishings or stored items, the inspector may not be able to verify that a heat source is present in all "liveable" rooms (e.g. bedrooms, kitchens and living/dining rooms).
General heating system type(s): Forced air, Furnace, Electric heaters
General heating distribution type(s): Ducts and registers
Last service date of primary heat source: Unknown
Electric heater type (not forced air): In-ceiling, fan-assisted
Manufacturer of electric heaters (not forced air): King
Forced air heating system fuel type: Natural gas
Estimated age of forced air furnace: 2010
Forced air heating system manufacturer: Trane
Location of forced air furnace: Closet
Location for forced air filter(s): At base of air handler
Type of combustion air supply: Vent(s) to exterior
Condition of cooling system and/or heat pump: Appeared serviceable
Cooling system and/or heat pump fuel type: Electric
Type: Split system
Estimated age of heat pump or air conditioning unit: 2010
Manufacturer of cooling system and/or heat pump: Trane
15) Furnace and A/C were functioning at time of inspection.
The inspector was unable to determine the last service date for the HVAC system. Ask the property owner when it was last serviced. If this system was serviced more than 1 year ago, recommend that a qualified HVAC contractor inspect, clean, and service this system, and make repairs if necessary. For safety reasons, and because this system is fueled by gas, this servicing should be performed annually in the future. Any needed repairs noted in this report should be brought to the attention of the HVAC contractor when it's serviced.
The filter should be changed upon move in. How often a filter should be changed depends on environmental factors (ie pets, smoking, dust, etc) but a general rule of thumb is every 3 months. Adjust time according to observation.
The estimated useful life for most forced air furnaces is 15-20 years, A/C condensing units is 10-15 years. This furnace and A/C condensing unit appeared to be near this age and may need replacing or significant repairs at any time. Recommend budgeting for a replacement in the future.
16) The serviceman's switch that controls power to the furnace was not clearly labeled. Recommend permanently labeling this switch to avoid confusion and unintentional loss of power if the switch is mistaken for a light switch.
Photo 16-1
17) The electric heaters were tested and were in working order at time of inspection. Annual review and cleaning are recommended for safety and function.
Limitations: The following items are not included in this inspection: household appliances such as stoves, ovens, cook tops, ranges, dishwashers, refrigerators, freezers, ice makers, hot water dispensers and water filters; Any comments made regarding these items are as a courtesy only. Note that the inspector does not provide an estimate of the remaining life of appliances, and does not determine the adequacy of operation of appliances. The inspector does not note appliance manufacturers, models or serial numbers and does not determine if appliances are subject to recalls. Areas and components behind and obscured by appliances are inaccessible and excluded from this inspection.
Condition of sinks and related plumbing: Serviceable.
Condition of under-sink food disposal: Appears serviceable
Condition of dishwasher: Appears serviceable.
Range, cooktop or oven type: Natural gas
Type of ventilation: Hood over range or cooktop, ducted to exterior
Condition of refrigerator: Appeared serviceable
Condition of built-in microwave oven: Serviceable.
18) No high loop or air gap was visible for the dishwasher drain. A high loop is created by routing the drain line up to the bottom surface of the counter top above and securely fastening it to that surface. An air gap is a device that makes the drain line non-continuous. Both of these prevent waste-water backflow from entering the dishwasher, and possibly flooding out of the dishwasher if/when a siphon occurs. Some newer dishwashers have these devices built in. The client should try to determine if these devices are built in to this brand and model of dishwasher (e.g. review installation instructions). If not, or if this cannot be determined, then recommend that a qualified person install a high loop and air gap per standard building practices.
Photo 18-1 Photo 18-2
19) Inspector performs a limited function test of appliances and runs dishwasher for short cycle. Deficiencies at time of inspection are noted above if present.
Inspector removed dishwasher toe kick and no leaks were observed at time of inspection.
Limitations: The following items are not included in this inspection: overflow drains for tubs and sinks; heated towel racks, saunas, steam generators, clothes washers, clothes dryers. Any comments made regarding these items are as a courtesy only. Note that the inspector does not determine the adequacy of washing machine drain lines, washing machine catch pan drain lines, or clothes dryer exhaust ducts. The inspector does not operate water supply or shut-off valves for sinks, toilets, bidets, clothes washers, etc. due to the possibility of valves leaking or breaking when operated. The inspector does not determine if shower pans or tub and shower enclosures are water tight, or determine the completeness or operability of any gas piping to laundry appliances.
Location #A: Half bath, second floor
Location #B: Full bath, second floor
Location #C: Full bath, Master bath, second floor
Location #D: Laundry room/area
Condition of counters: Serviceable.
Condition of cabinets: Appeared serviceable
Condition of flooring: Satisfactory
Condition of sinks and related plumbing: Serviceable.
Condition of toilets: Serviceable.
Condition of bathtubs and related plumbing: Serviceable.
Condition of shower(s) and related plumbing: Serviceable.
Bathroom and laundry ventilation type: Spot exhaust fans, with individual ducts
Gas supply for laundry equipment present: No
240 volt receptacle for laundry equipment present: Yes
20) The jetting system for the bathtub was leaking. Recommend that a qualified contractor evaluate and repair as necessary.
Photo 20-1 Photo 20-2
Photo 20-3 Photo 20-4
Photo 20-5 Photo 20-6
21) Fill valve/ball cock was leaking at toilet at location(s) #A . As leak is within tank, no adverse conditions were observed. This does indicate fill valve will need replacing in the future. These can be obtained at most home improvement stores.
Photo 21-1
22) Inspector ran water in the sink(s) and bathtub(s). Ran shower water and flushed toilet(s). No leaks were noted at time of inspection.
Photo 22-1 Photo 22-2
Photo 22-3 Photo 22-4
Photo 22-5 Photo 22-6
Photo 22-7 Photo 22-8
Photo 22-9 Photo 22-10
Photo 22-11 Photo 22-12
23) The jetted tub was in working order at time of inspection. The tub was on a GFCI circuit.
Debris came out of the jets when the jetted bathtub was turned on. Some jetted tub designs allow water to stagnate in pipes, resulting in mold or bacteria growth that is expelled from jets. It's unlikely that repairs or modifications can be made to prevent this if it is occurring. It may be possible to prevent such biological growth by running hot water and bleach or dishwasher soap (low sudsing) through the jetted bathtub periodically. For more information, visit: http://www.reporthost.com/?MOLDJETS
Photo 23-1 Photo 23-2
Photo 23-3 Photo 23-4
24) Recommend clearing dryer duct of lint upon move in and periodically in the future to reduce fire hazard. Dryer vent should be as straight and short as possible to minimize lint collection.
Limitations: The following items are not included in this inspection: security, intercom and sound systems; communications wiring; central vacuum systems; elevators and stair lifts; cosmetic deficiencies such as nail-pops, scuff marks, dents, dings, blemishes or issues due to normal wear and tear in wall, floor and ceiling surfaces and coverings, or in equipment; deficiencies relating to interior decorating; low voltage and gas lighting systems. Any comments made regarding these items are as a courtesy only. Note that the inspector does not evaluate any areas or items which require moving stored items, furnishings, debris, equipment, floor coverings, insulation or similar materials. The inspector does not test for asbestos, lead, radon, mold, hazardous waste, urea formaldehyde urethane, or any other toxic substance. Some items such as window, drawer, cabinet door or closet door operability are tested on a sampled basis. The client should be aware that paint may obscure wall and ceiling defects, floor coverings may obscure floor defects, and furnishings may obscure wall, floor and floor covering defects. If furnishings were present during the inspection, recommend a full evaluation of walls, floors and ceilings that were previously obscured when possible. Determining the cause and/or source of odors is not within the scope of this inspection.
Exterior door material: Metal, Fiberglass or vinyl, Sliding glass
Type(s) of windows: Vinyl, Multi-pane, Casement, Fixed
Wall type or covering: Drywall
Ceiling type or covering: Drywall
Flooring type or covering: Carpet, Wood or wood products, Tile
Condition of stairs, handrails and guardrails: Satisfactory
Condition of walls and ceilings: Satisfactory
25) Condensation or staining was visible between multi-pane glass in many windows. This usually indicates that the seal between the panes of glass has failed or that the desiccant material that absorbs moisture is saturated. As a result, the view through the window may be obscured, the window's R-value will be reduced, and accumulated condensation may leak into the wall structure below. Recommend that a qualified contractor evaluate and repair windows as necessary. Usually, this means replacing the glass in window frames.
Be aware that evidence of failed seals or desiccant may be more or less visible depending on the temperature, humidity, sunlight, etc. Windows or glass-paneled doors other than those that the inspector identified may also have failed seals and need glass replaced. It is beyond the scope of this inspection to identify every window with failed seals or desiccant.
The half bathroom, closet and living room
Photo 25-1 Photo 25-2
Photo 25-3 Photo 25-4
Photo 25-5 Photo 25-6
Photo 25-7 Photo 25-8
26) A central vacuum system was found. Recommend that the client consult with the property owner or review documentation to familiarize themselves with the operation of this system.
Photo 26-1 Photo 26-2
27) A elevator was found. Transfer switches and any associated electrical are a specialty system. Recommend that the client consult with the property owner or review documentation to familiarize themselves with the operation of this system
Photo 27-1 Photo 27-2
Photo 27-3 Photo 27-4
This report is not a guaranty or warranty. Anything can fail at any time. This inspection report is only reporting on the conditions as observed at the time of the inspection, and is not intended to be considered as a guaranty or warranty, expressed or implied, of the adequacy of, or performance of, systems or structures, or their component parts, or of their remaining life expectancy or usefulness. Systems, equipment and components can, and do, fail—randomly and without prior warning.
Please review your pre-inspection agreement We appreciate the opportunity to be of service. Should you have any questions about the general condition of the house in the future, we would be happy to answer these. There is no fee for this telephone consulting. Our fees are based on a single visit to the property. If additional visits are required for any reason, additional fees may be assessed.