Client(s): The Savvy Buyers
Property address: 9876 New Construction Way

Coeur D'Alene Id 83814
Inspection date: Wednesday, July 26, 2023

This report published on Friday, March 8, 2024 10:37:05 AM PST

Please understand that there are limitations to this inspection. Many components of the home are not visible during the inspection and very little historical information is provided in advance of the inspection. While we can reduce your risk of purchasing a home, we cannot eliminate it, nor can we assume it. Even the most comprehensive inspection cannot be expected to reveal every condition you may consider significant to ownership. In addition to those improvements recommended in our report, we recommend that you budget for unexpected repairs. On average, we have found that setting aside roughly one percent of the value of the home on an annual basis is sufficient to cover unexpected repairs.

ASHI Certified Inspector
Click to verify
Click to verify
Passed the National Home Inspector ExaminationState of IdahoMFD Home Certifications

How to Read this Report
This report is organized by the property's functional areas. Within each functional area, descriptive information is listed first and is shown in bold type. Items of concern follow descriptive information. Concerns are shown and sorted according to these types:
Concern typeSafetyPoses a safety hazard
Concern typeRepair RecommendedItem was not functioning as designed or intended. Correction should be performed, and may require a professional, specialist, or other knowledgeable person.
Concern typeMaintenance ReminderRecommend routine attention and maintenance to keep item in proper working condition.
Concern typeInvestigate FurtherRecommend additional investigation, research, or review by a specialist and/or client
Concern typeInformational CommentReport comment included for your information and consideration.

Click here for a glossary of building construction terms.Contact your inspector If there are terms that you do not understand, or visit the glossary of construction terms at https://www.reporthost.com/glossary.asp

Table of Contents

General Information
Grounds
Exterior and Foundation
Crawl Space
Roof
Attic and Roof Structure
Garage
Electric
Plumbing / Fuel Systems
Water Heater
Heating, Ventilation & A/C If Applicable (HVAC)
Fireplaces, Stoves, Chimneys and Flues
Kitchen
Bathrooms, Laundry and Sinks
Interior, Doors and Windows
View summary

General InformationTable of contents
Time started: 8:00am
Present during inspection: Client
Client present for discussion at end of inspection: Yes
Inspector: Patrick
Weather conditions during inspection: Dry (no rain), Sunny
Temperature during inspection: Warm, 70 degrees
Ground condition: Dry
Recent weather: Dry (no rain)
Sq. footage.: 3236
Buildings inspected: One house
Age of main building: 2023
Front of building faces: South
Occupied: No
1)  To view the summary. Click on the link in the upper left hand corner or under table contents.
2)  The client should be aware that a break-in period occurs during the first year or two after a building is constructed. Some amount of settlement and shrinkage is inevitable as temperature and humidity varies during the seasons. Systems may need adjustment or repair after experiencing constant, prolonged and/or heavy usage. Overall performance of the building exterior has not yet been tested by a wide variety of weather conditions.

Also, it is beyond the scope of this inspection to determine if all permits have been approved or signed off. Consult with the builder and/or municipality to determine if all necessary permits have been approved.
Photo
Photo 2-1 
Photo
Photo 2-2 
Photo
Photo 2-3 
Photo
Photo 2-4 
Limitations: Unless specifically included in the inspection, the following items and any related equipment, controls, electric systems and/or plumbing systems are excluded from this inspection: detached buildings or structures; fences and gates; retaining walls; underground drainage systems, catch basins or concealed sump pumps; swimming pools and related safety equipment, spas, hot tubs or saunas; whether deck, balcony and/or stair membranes are watertight; trees, landscaping, properties of soil, soil stability, erosion and erosion control; ponds, water features, irrigation or yard sprinkler systems; sport courts, playground, recreation or leisure equipment; areas below the exterior structures with less than 3 feet of vertical clearance; invisible fencing; sea walls, docks and boathouses; retractable awnings. Any comments made regarding these items are as a courtesy only.
Fence and gate material: vinyl
Site profile: Minor slope
Driveway material: Poured in place concrete
Sidewalk material: Poured in place concrete
Deck, patio, porch cover material and type: Covered (Refer to Roof section)
Deck, porch and/or balcony material: Concrete
3)  Minor damage was observed at fence.
Photo
Photo 3-1 
Photo
Photo 3-2 
Exterior and FoundationTable of contents
Limitations: The inspector performs a visual inspection of accessible components or systems at the exterior. Items excluded from this inspection include below-grade foundation walls and footings; foundations, exterior surfaces or components obscured by vegetation, stored items or debris; wall structures obscured by coverings such as siding or trim. This may limit a full evaluation. Regarding foundations, some amount of cracking is normal in concrete slabs and foundation walls due to shrinkage and drying. Note that the inspector does not determine the adequacy of seismic reinforcement.
Wall inspection method: Viewed from ground
Apparent wall structure: Wood frame
Wall covering: Cement fiber, Stone or faux stone veneer, Wood fiber
Apparent foundation type: Crawl space
Foundation/stem wall material: Poured in place concrete
Footing material (under foundation stem wall): Poured in place concrete
4)  The paint or stain finish in some areas was failing (e.g. peeling, faded, worn, thinning). Siding and trim with a failing finish can be damaged by moisture. Recommend that a qualified contractor prep (e.g. clean, scrape, sand, prime, caulk) and repaint or restain the building exterior where necessary and per standard building practices. Any repairs needed to the siding or trim should be made prior to this.
Photo
Photo 4-1 
Photo
Photo 4-2 
Photo
Photo 4-3 
Photo
Photo 4-4 
5)  Exhaust duct end caps were painted shut and didn't fully open. Blocked ducts can cause fan motors to overheat. Recommend that a qualified person repair exhaust caps. For example, cut paint from louvres.

One crawlspace vent well was dented. Air flow was not impeded at time of inspection.
Photo
Photo 5-1 
Photo
Photo 5-2 
6)  Minor caulking was needed at areas and minor looseness in some siding was observed.
Photo
Photo 6-1 
Photo
Photo 6-2 
Photo
Photo 6-3 
Photo
Photo 6-4 
Limitations: Structural components such as joists and beams, and other components such as piping, wiring and/or ducting that are obscured by under-floor insulation are excluded from this inspection. The inspector does not guarantee or warrant that water will not accumulate in the crawl spaces in the future. Complete access to all crawl space areas during all seasons and during prolonged periods of all types of weather conditions (e.g. heavy rain, melting snow) would be needed to do so. Note that crawl space areas should be checked at least annually for water intrusion, plumbing leaks and pest activity.
Crawl space inspection method: Traversed
Location of crawl space access point #A: Garage
Crawl space access points that were opened and viewed, traversed or partially traversed: A
Sub-floor material: Oriented strand board
Pier or support post material: Bearing wall
Floor structure above: Engineered wood joists
Insulation material underneath floor above: Fiberglass roll or batt
Vapor barrier present: Yes
Ventilation type: with vents
7)  Microbial staining was visible on floor sheathing in the crawlspace. Such staining usually occurs due to elevated humidity in the crawlspace during construction, and subsequent elevated moisture levels in the sheathing. When humid crawlspace conditions have been corrected, it's likely that such staining will stop growing. Mold abatement specialists can remediate current microbial staining which typically involves the following:
  • Clean microbial staining from wood surfaces
  • Treat wood surfaces with mildewcides
  • Prime wood with special primers
Note that the inspector is not a mold specialist or industrial hygienist and provides no professional opinion on health issues related to microbial growth.
Photo
Photo 7-1 
Photo
Photo 7-2 
Photo
Photo 7-3 
Photo
Photo 7-4 
Photo
Photo 7-5 
Photo
Photo 7-6 
8)  Under-floor insulation was falling down in one area. This may result in reduced energy efficiency. Recommend that a qualified person repair or replace insulation as necessary
Photo
Photo 8-1 
9)  The crawl space was dry at time of inspection. Note that all crawlspace areas should be checked periodically for water intrusion, plumbing leaks and pest activity.
Photo
Photo 9-1 
Photo
Photo 9-2 
Photo
Photo 9-3 
Photo
Photo 9-4 
Photo
Photo 9-5 
Photo
Photo 9-6 
Limitations: The following items or areas are not included in this inspection: areas that could not be traversed or viewed clearly due to lack of access; Any comments made regarding these items are made as a courtesy only. Note that the inspector does not provide an estimate of remaining life on the roof surface material, nor guarantee that leaks have not occurred in the roof surface, skylights or roof penetrations in the past. Regarding roof leaks, only active leaks, visible evidence of possible sources of leaks, and evidence of past leaks observed during the inspection are reported on as part of this inspection. The inspector does not guarantee or warrant that leaks will not occur in the future. Complete access to all roof and attic spaces during all seasons and during prolonged periods of all types of weather conditions (e.g. high wind and rain, melting snow) would be needed to do so. Occupants should monitor the condition of roofing materials in the future.
Roof inspection method: Partially traversed
Roof surface material: Architectural shingles
Roof type: Gable
Apparent number of layers of roof surface material: One
Gutter and downspout material: Metal
Gutter and downspout installation: Full
10)  Gaps were found in or around roof soffits and can allow birds or vermin to enter the attic. Recommend that a qualified person repair as necessary to eliminate gaps.
Photo
Photo 10-1 
Photo
Photo 10-2 
Photo
Photo 10-3 
Photo
Photo 10-4 
11)  The rain cap for the garage heating b-vent needs to be sealed. Leaks can occur. Recommend that a qualified person repair as needed.
Photo
Photo 11-1 
12)  Architectural roofing has an average life expectancy between 25 to 35 years depending on the weather conditions and attic ventilation.

http://www.improvementcenter.com/roofing/new-roofing-years-it-can-last.html

Minor wavy roofing was observed at rear of house.
Photo
Photo 12-1 
Photo
Photo 12-2 
Photo
Photo 12-3 
Photo
Photo 12-4 
Photo
Photo 12-5 
Photo
Photo 12-6 
Photo
Photo 12-7 
Photo
Photo 12-8 
Attic and Roof StructureTable of contents
Limitations: The following items or areas are not included in this inspection: areas that could not be traversed or viewed clearly due to lack of access; areas and components obscured by insulation. Any comments made regarding these items are made as a courtesy only. Complete access to all roof and attic spaces during all seasons and during prolonged periods of all types of weather conditions (e.g. high/low temperatures, high/low humidity, high wind and rain, melting snow) would be needed to do so.
Attic inspection method: Traversed
Location of attic access point #A: Bedroom closet
Attic access points that were opened and viewed, traversed or partially traversed: A
Roof structure type: Trusses
roof material: Oriented strand board
Ceiling structure: Trusses
Ceiling insulation material: Fiberglass roll or batt, Cellulose loose fill
Roof ventilation type: Ridge vent(s), Enclosed soffit vents
13)  Attic access hatch was missing. Recommend a qualified person install insulated hatch cover..
Photo
Photo 13-1 
Photo
Photo 13-2 
14)  Some framing at hip appeared substandard when compared to best building practices at hip at approximate center of house. For example, rafter ends not flush cut, truss/rafter extensions not support for hip roof. Recommend confirming with builder that this is to engineered specs.
Photo
Photo 14-1 
Photo
Photo 14-2 
Photo
Photo 14-3 
Photo
Photo 14-4 
Photo
Photo 14-5 
Photo
Photo 14-6 
15)  Attic insulation and venting.

Attic spaces less than 30 inches in height may exist in this building above bonus area, but had no visible access points. This is acceptable per standard building practices. However, these spaces were not inspected and are excluded from this inspection.
Photo
Photo 15-1 
Photo
Photo 15-2 
Photo
Photo 15-3 
Photo
Photo 15-4 
Photo
Photo 15-5 
Photo
Photo 15-6 
Photo
Photo 15-7 
Photo
Photo 15-8 
Limitations: The inspector does not determine the adequacy of firewall ratings. Requirements for ventilation in garages vary between municipalities.
Type: Attached
Type of door between garage and house: Solid core, With visible fire-resistance rating
Exterior door material: Metal
Type of garage vehicle door: Sectional
Number of vehicle doors: 2
Mechanical auto-reverse operable (reverses when meeting reasonable resistance during closing): Yes
16)  Garage vehicle doors were balanced at time of inspection.

Weather stripping was loose.

More info:
https://www.youtube.com/watch?v=EP541HaUVhs
Photo
Photo 16-1 
Photo
Photo 16-2 
Limitations: The inspector does not operate circuit breakers as part of the inspection, and does not install or change light bulbs. The inspector does not evaluate every wall switch or receptacle, but instead tests a representative number of them per various standards of practice. When furnishings, stored items or child-protective caps are present some receptacles are usually inaccessible and are not tested; these are excluded from this inspection. Receptacles that are not of standard 110 volt configuration, including 240-volt dryer receptacles, are not tested and are excluded. The functionality of, power source for and placement of smoke and carbon monoxide alarms is not determined as part of this inspection. Upon taking occupancy, proper operating and placement of smoke and carbon monoxide alarms should be verified and batteries should be changed. These devices have a limited lifespan and should be replaced every 10 years. The inspector attempts to locate and evaluate all main and sub-panels. However, panels are often concealed. If panels are found after the inspection, a qualified electrician should evaluate and repair if necessary. The inspector attempts to determine the overall electrical service size, but such estimates are not guaranteed because the overall capacity may be diminished by lesser-rated components in the system. Any repairs recommended should be made by a licensed electrician.
Primary service type: Underground
Number of service conductors: 3
Service voltage (volts): 120-240
Estimated service amperage: 200
Primary service overload protection type: Circuit breakers
Service entrance conductor material: Stranded aluminum
Main disconnect rating (amps): 200
System ground: Concrete encased electrode
Location of main service panel #A: Garage
Location of main disconnect: Breaker at top of main service panel
Branch circuit wiring type: Non-metallic sheathed, Copper
Ground fault circuit interrupter (GFCI) protection present: Yes
Arc fault circuit interrupter (AFCI) protection present: Yes
Smoke alarms installed: Yes
Carbon monoxide alarms installed: Yes
17)  Light was missing at the front garage soffit. Recommend a qualified person install light.
Photo
Photo 17-1 
18)  Knockout was missing at exterior panel. Rodents can enter panels through holes. Recommend that a qualified person install knockout covers where missing and per standard building practices.
Photo
Photo 18-1 
19)  Light fixtures were inoperable (didn't turn on when nearby switches were operated). Sensors were present which may prevent lights from turning on when light outside.

Recommend further evaluation by checking with builder about switches and/or sensors.
Photo
Photo 19-1 
Photo
Photo 19-2 
Photo
Photo 19-3 
Photo
Photo 19-4 
20)  Equipment for a generator system was found. Generators, transfer switches and any associated wiring are excluded from this inspection. Recommend that the client consult with the property owner or review documentation to familiarize themselves with the operation of this system.
Photo
Photo 20-1 
Photo
Photo 20-2 
21)  The house meets current standards.

Current safety standards recommend smoke alarms should be installed in each bedroom, in hallways leading to bedrooms, and on each level. They have a limited lifespan and should be replaced every 10 years. Batteries in smoke alarms should be changed when taking occupancy and annually in the future. Carbon monoxide alarms should be installed near sleeping areas and on each level in homes with a fuel-burning appliance or attached garage. For more information, visit:
http://www.reporthost.com/?SMKALRM
http://www.reporthost.com/?COALRM
Photo
Photo 21-1 
Photo
Photo 21-2 
22)  Electrical panel appears well labeled.
Photo
Photo 22-1 
Photo
Photo 22-2 
Photo
Photo 22-3 
Plumbing / Fuel SystemsTable of contents
Limitations: The following items are not included in this inspection: private/shared wells and related equipment; private sewage disposal systems; hot tubs or spas; main, side and lateral sewer lines; gray water systems; pressure boosting systems; trap primers; incinerating or composting toilets; fire suppression systems; water softeners, conditioners or filtering systems; plumbing components concealed within the foundation or building structure, or in inaccessible areas such as below tubs; underground utilities and systems; overflow drains for tubs and sinks; backflow prevention devices. Any comments made regarding these items are as a courtesy only. Note that the inspector does not operate water supply or shut-off valves due to the possibility of valves leaking or breaking when operated. The inspector does not test for lead in the water supply, the water pipes or solder, does not determine if plumbing and fuel lines are adequately sized, and does not determine the existence or condition of underground or above-ground fuel tanks.
Water service: Public
Water pressure (psi): 70
Location of main water meter: By sidewalk in front of house
Location of main water shut-off: Garage
Service pipe material: Plastic
Supply pipe material: PEX plastic
Drain pipe material: Plastic
Waste pipe material: Plastic
Location(s) of plumbing clean-outs: Building exterior
Vent pipe material: Plastic
Location of main fuel shut-off valve: At gas meter
Location of main fuel shut-off valve: By furnace
23)  Leaks were found in drain pipes or fittings under spare bathroom tub. A qualified plumber should evaluate and repair as necessary.
Photo
Photo 23-1 
Photo
Photo 23-2 
24)  Based on visible equipment, this property appeared to have a yard irrigation (sprinkler) system. These are specialty systems and are not a part of a typical home inspection. A recent backflow test tag was not visible. Backflow tests are required annually in many municipalities in our area to prevent cross-contamination of potable water. Recommend asking current owners about test and obtaining work orders if available. If no test has been performed, recommend a qualified specialist perform a backflow test.
Photo
Photo 24-1 
Photo
Photo 24-2 
25)  Water pressure taken at the house measured 70 PSI. Typical residential water pressure is 40 to 80 PSI.
Photo
Photo 25-1 
26)  One sewer clean out was noted at the front of the house.
Photo
Photo 26-1 
27)  Main water shutoff valve is located in garage.

Main gas shutoff is located at meter at side of house.
Photo
Photo 27-1 
Photo
Photo 27-2 
Water HeaterTable of contents
Type: Tankless
Energy source: Natural gas
Estimated age: 2022
Temperature-pressure relief valve installed: Yes
Manufacturer: Bradford White
Location of water heater: Garage
Hot water temperature tested: No
Water temperature (degrees Fahrenheit): 131
28)  Digital display was inoperable at time of inspection. Builder stated part was coming to repair.

The hot water temperature was greater than 120 degrees Fahrenheit. This is a safety hazard due to the risk of scalding. The thermostat should be adjusted so the water temperature doesn't exceed 120 degrees

A tankless water heater was observed at this property. It is beyond the scope of this inspection to determine the adequacy of this system since demand varies significantly with water usage. For example, with simultaneous showers while washing clothes or dishes, etc. During such usage, tankless water heaters may not keep up with demand. This inspection includes a limited evaluation of the water heater to determine the following:
  • Does it supply hot water?
  • Is the water pressure adequate for the unit (typically minimum 30-50 psi)?
  • Is combustion air and the venting system serviceable?
  • Is the wiring for the electric supply safe?
  • Is a temperature-pressure relief valve and drain line installed?
Any concerns observed related to the above items are noted in this report.

NAVIAN 240A Cleaning instructions. https://www.youtube.com/watch?v=yBkTk3bTmnY
Photo
Photo 28-1 
Photo
Photo 28-2 
Photo
Photo 28-3 
Photo
Photo 28-4 
Heating, Ventilation & A/C If Applicable (HVAC)Table of contents
Limitations: The following items are not included in this inspection: humidifiers, dehumidifiers, electronic air filters; solar, coal or wood-fired heat systems; thermostat or temperature control accuracy and timed functions; heating components concealed within the building structure or in inaccessible areas; underground utilities and systems; safety devices and controls (due to automatic operation). Any comments made regarding these items are as a courtesy only. Note that the inspector does not provide an estimate of remaining life on heating or cooling system components, does not determine if heating or cooling systems are appropriately sized, does not test coolant pressure, or perform any evaluations that require a pilot light to be lit, a shut-off valve to be operated, a circuit breaker to be turned "on" or a serviceman's or oil emergency switch to be operated. It is beyond the scope of this inspection to determine if furnace heat exchangers are intact and free of leaks. Condensation pans and drain lines may clog or leak at any time and should be monitored while in operation in the future. Where buildings contain furnishings or stored items, the inspector may not be able to verify that a heat source is present in all "liveable" rooms (e.g. bedrooms, kitchens and living/dining rooms).
General heating system type(s): Forced air, Furnace
General heating distribution type(s): Ducts and registers
Last service date of primary heat source: New
Forced air heating system fuel type: Natural gas
Estimated age of forced air furnace: 2022
Forced air heating system manufacturer: Rheem
Forced air furnace serial number: W032243636
Location of forced air furnace: Attic
Forced air system capacity in BTUs or kilowatts: 70,000
Location for forced air filter(s): Behind return air grill(s)
Cooling system and/or heat pump fuel type: Electric
Type: Split system
Estimated age of heat pump or air conditioning unit: 2022
Approximate tonnage: 3
Manufacturer of cooling system and/or heat pump: Rheem
Heat pump or air conditioner serial number: W252204423
29)  No serviceman's switch was visible for the furnace. This is a switch that allows power to be turned off quickly if something goes wrong when someone is performing maintenance or repairs. This is a potential safety hazard. Requirements vary by municipality, but general guidelines require the switch be within an arm's length of the appliance. In some cases the disconnect at the electric panel (e.g. circuit breaker or fuse) may suffice if it's within sight of the appliance. Recommend that a qualified contractor install a serviceman's switch per standard building practices.
Photo
Photo 29-1 
Photo
Photo 29-2 
30)  The air handler's primary condensate drain line was leaking in attic. Condensate drain water may accumulate, leak and cause water damage to surrounding areas. Recommend that a qualified HVAC contractor repair as necessary.
Photo
Photo 30-1 
Photo
Photo 30-2 
31)  Work space platform in attic appeared to be inadequate. Minimum 30 inches for depth and width in front of appliance is recommended. Recommend a qualified specialist evaluate and repair as necessary.
Photo
Photo 31-1 
32)  The catch pan for the high-efficiency furnace and air conditioning equipment in attic was filled with insulation. These systems produce condensation which is normally eliminated via a primary drain line. However, condensate water can leak if the primary drain line clogs. A catch pan is installed below the air handler, with a float switch that will turn off the system if water accumulates in the catch pan. Insulation can affect this function and should be cleared from pan and float switch.
Photo
Photo 32-1 
Photo
Photo 32-2 
Photo
Photo 32-3 
Photo
Photo 32-4 
33)  Drywall dust, and construction debris such as drywall dust and/or sawdust was found behind or below heating or cooling air supply registers. Drywall dust in particular can reduce the life of heating and cooling equipment if left to circulate. At a minimum, recommend vacuuming ducts at each register. Consider having a qualified contractor clean the ducts.

Register in bonus area closet was ill fitting.

Only one register was present in bonus living area. One was located in bathroom and one in closet. It is beyond the scope of a home inspection to determine if this is adequate for the space.
Photo
Photo 33-1 
Photo
Photo 33-2 
Photo
Photo 33-3 
Photo
Photo 33-4 
34)  Furnace and A/C was functioning at time of inspection.

Unit is new, recommend annual servicing in the future for warranty purposes.

The filter should be changed upon move in. How often a filter should be changed depends on environmental factors (ie pets, smoking, dust, etc) but a general rule of thumb is every 3 months. Adjust time according to observation.
Photo
Photo 34-1 
Photo
Photo 34-2 
Photo
Photo 34-3 
Photo
Photo 34-4 
Photo
Photo 34-5 
Photo
Photo 34-6 
Fireplaces, Stoves, Chimneys and FluesTable of contents
Limitations: The following items are not included in this inspection: coal stoves, gas logs, chimney flues (except where visible). Any comments made regarding these items are as a courtesy only. Note that the inspector does not determine the adequacy of drafting or sizing in fireplace and stove flues, and also does not determine if prefabricated or zero-clearance fireplaces are installed in accordance with the manufacturer's specifications. The inspector does not perform any evaluations that require a pilot light to be lit, and does not light fires. The inspector provides a basic visual examination of a chimney and any associated wood burning device. The National Fire Protection Association has stated that an in-depth Level 2 chimney inspection should be part of every sale or transfer of property with a wood-burning device. Such an inspection may reveal defects that are not apparent to the home inspector who is a generalist.
Gas fireplace or stove type: Metal pre-fab fireplace
Fan or blower installed in gas-fired fireplace or stove: Yes
Gas-fired flue type: B-vent
35)  Gas fireplace was functional at time of inspection.

Lights within fireplace did not turn on.

The blower for the gas-fired fireplace or stove did not operate. The inspector did not determine why. This can be due to various reasons such as a switch that wasn't found, or a thermostat not reaching a high enough temperature. Consult with the property owner and review documentation for such appliances. If necessary, a qualified specialist should evaluate and repair.

Batteries were present at emergency electric start. Battery receiver is typically for emergency use only when power is out and fireplace needs to be operated. Batteries should not be stored in receiver due to risk of corrosion and damage to receiver.

Recommend that the client review all available documentation for gas-fired fireplaces and stoves. Depending on how they are operated (for routine heating versus ambiance), such appliances may need servicing annually or every few years.
Photo
Photo 35-1 
Photo
Photo 35-2 
Photo
Photo 35-3 
Photo
Photo 35-4 
Limitations: The following items are not included in this inspection: household appliances such as stoves, ovens, cook tops, ranges, dishwashers, refrigerators, freezers, ice makers, hot water dispensers and water filters; Any comments made regarding these items are as a courtesy only. Note that the inspector does not provide an estimate of the remaining life of appliances, and does not determine the adequacy of operation of appliances. The inspector does not note appliance manufacturers, models or serial numbers and does not determine if appliances are subject to recalls. Areas and components behind and obscured by appliances are inaccessible and excluded from this inspection.
Permanently installed kitchen appliances present during inspection: Range, Dishwasher, Refrigerator, Under-sink food disposal, Microwave oven
Condition of counters: Serviceable.
Condition of cabinets: Appeared serviceable
Condition of sinks and related plumbing: Serviceable.
Condition of under-sink food disposal: Required repair, replacement and/or evaluation (see comments below)
Condition of dishwasher: Appears serviceable.
Condition of range, cooktop or oven: Appears serviceable.
Range, cooktop or oven type: Natural gas
Type of ventilation: Hood over range or cooktop
Condition of refrigerator: Appeared serviceable
Condition of built-in microwave oven: Serviceable.
36)  The under-sink food disposal was inoperable as it was not completely installed. Recommend that a qualified contractor repair or replace as necessary.
Photo
Photo 36-1 
Photo
Photo 36-2 
37)  Handle was not installed on microwave.
Photo
Photo 37-1 
Photo
Photo 37-2 
38)  No dishwasher toe kick was installed and no leaks were observed at time of inspection.

Inspector performs a limited function test of appliances and runs dishwasher for short cycle. Deficiencies at time of inspection are noted above if
Photo
Photo 38-1 
Photo
Photo 38-2 
Photo
Photo 38-3 
Photo
Photo 38-4 
Photo
Photo 38-5 
Photo
Photo 38-6 
Photo
Photo 38-7 
Photo
Photo 38-8 
Bathrooms, Laundry and SinksTable of contents
Limitations: The following items are not included in this inspection: overflow drains for tubs and sinks; heated towel racks, saunas, steam generators, clothes washers, clothes dryers. Any comments made regarding these items are as a courtesy only. Note that the inspector does not determine the adequacy of washing machine drain lines, washing machine catch pan drain lines, or clothes dryer exhaust ducts. The inspector does not operate water supply or shut-off valves for sinks, toilets, bidets, clothes washers, etc. due to the possibility of valves leaking or breaking when operated. The inspector does not determine if shower pans or tub and shower enclosures are water tight, or determine the completeness or operability of any gas piping to laundry appliances.
Location #A: Full bath, second floor
Location #B: Full bath, Master bath
Location #C: Half bath, first floor
Location #D: Full bath, first floor
Condition of counters: Serviceable.
Condition of cabinets: Appeared serviceable
Condition of flooring: Satisfactory
Condition of sinks and related plumbing: Serviceable.
Condition of toilets: Serviceable.
Condition of bathtubs and related plumbing: Required repair, replacement and/or evaluation (see comments below)
Condition of shower(s) and related plumbing: Serviceable.
Condition of ventilation systems: Satisfactory
Bathroom and laundry ventilation type: Windows, Spot exhaust fans
Gas supply for laundry equipment present: No
240 volt receptacle for laundry equipment present: Yes
39)  Inspector could not get far third shower head and shower head on master bathtub to function in master bathroom. Recommend asking builder about function and repair if necessary.
Photo
Photo 39-1 
Photo
Photo 39-2 
Photo
Photo 39-3 
Photo
Photo 39-4 
40)  The hot and cold water supplies appeared to be reversed at the bathtub at location(s) #B according to markings on handle. Normally, cold water is controlled by the right faucet handle and hot by the left. For mixing faucets, cold is supplied with the handle to the right and hot when the handle is to the left, or as indicated by the faucet's markings. At a minimum this is an inconvenience, but it can also result in accidental scalding. Recommend that a qualified plumber repair as necessary.
Photo
Photo 40-1 
41)  The hot water supply flow for the laundry sink was inoperable. Recommend that a qualified plumber evaluate and repair as necessary.

Supply was off when inspector arrived. Inspector turned them on briefly to test.
Photo
Photo 41-1 
Photo
Photo 41-2 
42)  We recommend when first running the dryer to confirm that it is blowing to exterior by observing exterior louvres.
Photo
Photo 42-1 
43)  Inspector ran water in the sink(s) and bathtub(s). Ran shower water and flushed toilet(s). Leaks were noted at time of inspection, see plumbing section for further discussion.
Photo
Photo 43-1 
Photo
Photo 43-2 
Photo
Photo 43-3 
Photo
Photo 43-4 
Photo
Photo 43-5 
Photo
Photo 43-6 
Photo
Photo 43-7 
Photo
Photo 43-8 
Interior, Doors and WindowsTable of contents
Limitations: The following items are not included in this inspection: security, intercom and sound systems; communications wiring; central vacuum systems; elevators and stair lifts; cosmetic deficiencies such as nail-pops, scuff marks, dents, dings, blemishes or issues due to normal wear and tear in wall, floor and ceiling surfaces and coverings, or in equipment; deficiencies relating to interior decorating; low voltage and gas lighting systems. Any comments made regarding these items are as a courtesy only. Note that the inspector does not evaluate any areas or items which require moving stored items, furnishings, debris, equipment, floor coverings, insulation or similar materials. The inspector does not test for asbestos, lead, radon, mold, hazardous waste, urea formaldehyde urethane, or any other toxic substance. Some items such as window, drawer, cabinet door or closet door operability are tested on a sampled basis. The client should be aware that paint may obscure wall and ceiling defects, floor coverings may obscure floor defects, and furnishings may obscure wall, floor and floor covering defects. If furnishings were present during the inspection, recommend a full evaluation of walls, floors and ceilings that were previously obscured when possible. Determining the cause and/or source of odors is not within the scope of this inspection.
Exterior door material: Fiberglass or vinyl, Glass panel
Condition of interior doors: Satisfactory
Type(s) of windows: Vinyl, Multi-pane, Sliding, Single-hung, Fixed
Wall type or covering: Drywall
Ceiling type or covering: Drywall
Condition of flooring: Satisfactory
Flooring type or covering: Carpet, Wood or wood products, Tile
Condition of stairs, handrails and guardrails: Satisfactory
44)  Trim piece was missing from rear door.

Strike plate was missing at garage exterior door.
Photo
Photo 44-1 
Photo
Photo 44-2 
45)  Screens were not installed at windows. Inspector did not verify number and fit of screens.
Photo
Photo 45-1 
Photo
Photo 45-2 
46)  Minor cracks, nail pops and blemishes were found in walls, ceilings and floors in some areas.

Missing drywall was observed under laundry sink.

Shims were not finished at half bath sink.

Some minor finishing touches were not performed at time of inspection.
Photo
Photo 46-1 
Photo
Photo 46-2 
Photo
Photo 46-3 
Photo
Photo 46-4 
Photo
Photo 46-5 
Photo
Photo 46-6 
Photo
Photo 46-7 
Photo
Photo 46-8 
Photo
Photo 46-9 
Photo
Photo 46-10 
47)  Surface scratches were observed on bonus bathroom window.
Photo
Photo 47-1 
Photo
Photo 47-2