This report published on Tuesday, November 12, 2024 6:23:27 PM PST
Please understand that there are limitations to this inspection. Many components of the home are not visible during the inspection and very little historical information is provided in advance of the inspection. While we can reduce your risk of purchasing a home, we cannot eliminate it, nor can we assume it. Even the most comprehensive inspection cannot be expected to reveal every condition you may consider significant to ownership.
How to Read this Report
This report is organized by the property's functional areas. Within each functional area, descriptive information is listed first and is shown in bold type. Items of concern follow descriptive information.
Concerns are shown and sorted according to these types:
Repair Recommended
Item was not functioning as designed or intended. Correction should be performed, and may require a professional, specialist, or other knowledgeable person.
Maintenance Reminder
Recommend routine attention and maintenance to keep item in proper working condition.
Investigate Further
Recommend additional investigation, research, or review by a specialist and/or client
Informational Comment
Report comment included for your information and consideration.
Click here for a glossary of building construction terms.Contact your inspector If there are terms that you do not understand, or visit the glossary of construction terms at https://www.reporthost.com/glossary.asp
Client present for discussion at end of inspection: No
Inspector: Robert
Weather conditions during inspection: Sunny
Temperature during inspection: Warm
Recent weather: Sunny
Sq. footage.: 1826
Buildings inspected: One house
Age of main building: 2024
Source for main building age: Municipal records or property listing
Occupied: No
1) To view the summary. Click on the link in the upper left hand corner or under table contents.
2) General pictures, minor Knicks, blue tape items and general clean up are provided below as a courtesy but are not the focus of a home inspection. These are aesthetic in nature and are typically covered in a walk through with the builder.
The client should be aware that a break-in period occurs during the first year or two after a building is constructed. Some amount of settlement and shrinkage is inevitable as temperature and humidity varies during the seasons. Systems may need adjustment or repair after experiencing constant, prolonged and/or heavy usage. Overall performance of the building exterior has not yet been tested by a wide variety of weather conditions.
Also, it is beyond the scope of this inspection to determine if all permits have been approved or signed off. Consult with the builder and/or municipality to determine if all necessary permits have been approved.
Limitations: Unless specifically included in the inspection, the following items and any related equipment, controls, electric systems and/or plumbing systems are excluded from this inspection: detached buildings or structures; fences and gates; retaining walls; underground drainage systems, catch basins or concealed sump pumps; swimming pools and related safety equipment, spas, hot tubs or saunas; whether deck, balcony and/or stair membranes are watertight; trees, landscaping, properties of soil, soil stability, erosion and erosion control; ponds, water features, irrigation or yard sprinkler systems; sport courts, playground, recreation or leisure equipment; areas below the exterior structures with less than 3 feet of vertical clearance; invisible fencing; sea walls, docks and boathouses; retractable awnings. Any comments made regarding these items are as a courtesy only.
Fence and gate material: Vinyl
Site profile: Minor slope
Driveway material: Poured in place concrete
Sidewalk material: Poured in place concrete, Gravel
Deck, patio, porch cover material and type: Covered (Refer to Roof section)
Deck, porch and/or balcony material: Concrete
Exterior stair material: Concrete
3) Vent wells appeared to be compromised, refer to builder for repair.
Photo 3-1 Photo 3-2
Photo 3-3 Photo 3-4
4) Minor cracks were found in the sidewalk, but no trip hazards were found. Client should monitor and consider sealing cracks. Numerous products exist to seal such cracks including hydraulic cement, non-shrinking grout, resilient caulks and epoxy sealants.
Limitations: The inspector performs a visual inspection of accessible components or systems at the exterior. Items excluded from this inspection include below-grade foundation walls and footings; foundations, exterior surfaces or components obscured by vegetation, stored items or debris; wall structures obscured by coverings such as siding or trim. This may limit a full evaluation. Regarding foundations, some amount of cracking is normal in concrete slabs and foundation walls due to shrinkage and drying. Note that the inspector does not determine the adequacy of seismic reinforcement.
Wall inspection method: Viewed from ground
Apparent wall structure: Wood frame
Wall covering: Wood fiber, Cement fiber
Apparent foundation type: Crawl space
Foundation/stem wall material: Poured in place concrete
Footing material (under foundation stem wall): Poured in place concrete
5) Some sections of siding and/or trim were damaged. Recommend that a qualified person repair, replace or install siding or trim as necessary.
Photo 5-1 Photo 5-2
Photo 5-3 Photo 5-4
Photo 5-5 Photo 5-6
6) Holes or gaps were found in siding or trim. Vermin, insects or water may enter the structure. Recommend that a qualified person repair as necessary.
Photo 6-1 Photo 6-2
7) Clearances between the cement fiber siding and surfaces below were too small. Moisture may penetrate and damage the siding as a result, sheeting can wick up moisture and the manufacturer's warranty may be voided. Normally, minimum clearances below the bottom of cement fiber siding and trim include:
6 inches to the finished grade below
2 inches to paths, steps, driveways or deck surfaces below
2 inches to roof surfaces below
1/4 inch to horizontal flashing below, with no caulk applied
Recommend that a qualified contractor repair per the siding/trim manufacturer's specifications. For more information, visit: http://www.reporthost.com/?HARDIPLANK
Photo 7-1 Photo 7-2
Photo 7-3 Photo 7-4
Photo 7-5 Photo 7-6
Photo 7-7
8) Areas where wood siding or trim was installed above stone or masonry had no flashing below the wood. Flashing should be installed between masonry or stone and wood trim or siding above to keep water from accumulating at that gap. Without the flashing, the wood trim, siding, or the sheeting behind is prone to fungal rot and deterioration. Recommend that a qualified contractor install flashing where missing and per standard building practices.
Photo 8-1 Photo 8-2
Photo 8-3 Photo 8-4
Photo 8-5 Photo 8-6
Photo 8-7 Photo 8-8
Photo 8-9
9) Exhaust duct end caps were loose and didn't appear to fit in slots. Their purpose is to prevent unconditioned air from entering the building, and keep out birds, rodents and bugs. Blocked ducts can cause fan motors and/or clothes dryers to overheat and can pose a fire hazard. Recommend that a qualified person repair or replace caps as necessary.
Photo 9-1
10) Exterior brick veneer had a significant amount of mortar and blemished areas, refer to builder for options.
Photo 10-1 Photo 10-2
Photo 10-3 Photo 10-4
Photo 10-5 Photo 10-6
11) Windows or doors were installed with no "drip cap" or "Z" flashings installed above them. Better building practices call for such flashings, which greatly reduce the chance of leaks above windows and doors. Without this flashing, caulk and paint must be maintained or water can enter the wall structure and cause rot and possible structural damage. Depending on the exposure (e.g. roof overhang, height of exterior wall, direction of prevailing rain) this may or may not be an issue. The client should monitor these areas in the future and maintain caulk and paint as necessary. Consult with a qualified contractor about installing flashings where needed, and per standard building practices. Note that when trim or siding is removed to install flashing, damaged wood may be found and additional repairs may be needed.
Photo 11-1 Photo 11-2
Photo 11-3 Photo 11-4
12) Minor cracks (1/8 inch or less) were found in the foundation. These didn't appear to be a structural concern, but recommend sealing them to prevent water infiltration and monitor them in the future. Numerous products exist to seal such cracks including hydraulic cement, non-shrinking grout, resilient caulks and epoxy sealants.
Limitations: Structural components such as joists and beams, and other components such as piping, wiring and/or ducting that are obscured by under-floor insulation are excluded from this inspection. The inspector does not guarantee or warrant that water will not accumulate in the crawl spaces in the future. Complete access to all crawl space areas during all seasons and during prolonged periods of all types of weather conditions (e.g. heavy rain, melting snow) would be needed to do so. Note that crawl space areas should be checked at least annually for water intrusion, plumbing leaks and pest activity.
Crawl space inspection method: Traversed
Location of crawl space access point #A: Master bedroom closet
Crawl space access points that were opened and viewed, traversed or partially traversed: A
Sub-floor material: Oriented strand board
Pier or support post material: Bearing wall
Beam material: Built-up wood
Floor structure above: Engineered wood joists
Insulation material underneath floor above: Fiberglass roll or batt
Vapor barrier present: Yes, Full
Ventilation type: with vents
13) One engineered joist under master bathroom was notched in such a way as to weaken the joist(s). Limitations on modifying joists in the field vary depending on the manufacturer, but general guidelines often include these restrictions:
Top and bottom flanges should never be cut, drilled or notched.
The maximum-sized hole cut into the web should not exceed the distance between the flanges minus 1/4 inch.
The longest side of a rectangular hole should not exceed 3/4 of the maximum-sized hole allowed.
Holes should not be cut closer than 1/8 inch to either flange.
No more than three maximum-sized holes are allowed per span.
For multiple holes, the distance between adjacent hole edges must exceed twice the diameter of the largest round hole or twice the length of the longest side of any rectangular hole.
Ideally, holes should be centered on the middle of the web.
Ideally, rectangular holes should have rounded corners.
Recommend that a qualified contractor evaluate and repair as necessary, and per the joist manufacturer's specifications. Note that the inspector cannot determine if modifications to engineered joists comply with the manufacturer's specifications.
Photo 13-1 Photo 13-2
14) The crawl space was dry at time of inspection. Crawl space insulation and duct work satisfactory. Note that all crawlspace areas should be checked periodically for water intrusion, plumbing leaks and pest activity.
Please note, plumbing traps near vents can freeze if house is unoccupied during cold weather. Insulating traps can minimize this risk.
Limitations: The following items or areas are not included in this inspection: areas that could not be traversed or viewed clearly due to lack of access; Any comments made regarding these items are made as a courtesy only. Note that the inspector does not provide an estimate of remaining life on the roof surface material, nor guarantee that leaks have not occurred in the roof surface, skylights or roof penetrations in the past. Regarding roof leaks, only active leaks, visible evidence of possible sources of leaks, and evidence of past leaks observed during the inspection are reported on as part of this inspection. The inspector does not guarantee or warrant that leaks will not occur in the future. Complete access to all roof and attic spaces during all seasons and during prolonged periods of all types of weather conditions (e.g. high wind and rain, melting snow) would be needed to do so. Occupants should monitor the condition of roofing materials in the future.
Roof inspection method: Traversed
Roof surface material: Architectural shingles
Roof type: Shed
Gutter and downspout material: Metal
Gutter and downspout installation: Full
15) Nail heads were exposed at several shingles. Recommend applying an approved sealant over exposed nail heads now and as necessary in the future to prevent leaks.
Photo 15-1 Photo 15-2
Photo 15-3 Photo 15-4
Photo 15-5 Photo 15-6
Photo 15-7 Photo 15-8
Photo 15-9 Photo 15-10
Photo 15-11 Photo 15-12
Photo 15-13 Photo 15-14
Photo 15-15 Photo 15-16
Photo 15-17 Photo 15-18
16) Flashings were substandard in various places. Flashing should go under on the high side of the roof and over on the low side of the roof. Leaks can occur as a result Recommend that a qualified person repair as necessary.
Photo 16-1 Photo 16-2
Photo 16-3 Photo 16-4
Photo 16-5 Photo 16-6
Photo 16-7 Photo 16-8
Photo 16-9 Photo 16-10
17) The rain cap for the heating b-vent needs to be sealed. Leaks can occur. Recommend that a qualified person repair as needed.
Photo 17-1
18) Composition shingles were loose because the adhesive, self-sealing strips weren't sealed. Leaks can occur as a result. Self-sealing strips secure the lower edge of shingles and reduce vulnerability to wind damage. Strips may not be sealed because the sealant has failed or because the sealant never activated and cured after the original installation. Recommend that a qualified contractor repair as necessary. For example, by hand sealing shingles with an approved sealant.
Photo 18-1 Photo 18-2
Photo 18-3 Photo 18-4
Photo 18-5
19) Extensions such as splash blocks or drain pipes for downspouts were missing. Water can accumulate around the building foundation as a result. Recommend that a qualified person install, replace or repair extensions as necessary so rainwater drains away from the structure.
Photo 19-1 Photo 19-2
20) The siding at exterior walls was in contact with or too close to roof surfaces below. There should be a gap of 1 1/2 to 2 inches between a roof surface and siding above. The gap is meant to prevent water from wicking up into the bottom edge of the siding and causing fugal rot, or damaging the siding. There may also be inadequate space for additional layers of roofing materials in the future. Recommend that a qualified contractor repair per standard building practices. For example, by trimming the siding.
Photo 20-1
21) Architectural roofing has an average life expectancy between 25 to 35 years depending on the weather conditions and attic ventilation.
Limitations: The following items or areas are not included in this inspection: areas that could not be traversed or viewed clearly due to lack of access; areas and components obscured by insulation. Any comments made regarding these items are made as a courtesy only. Complete access to all roof and attic spaces during all seasons and during prolonged periods of all types of weather conditions (e.g. high/low temperatures, high/low humidity, high wind and rain, melting snow) would be needed to do so.
Attic inspection method: Traversed
Location of attic access point #A: Master bedroom closet
Attic access points that were opened and viewed, traversed or partially traversed: A
Roof structure type: Trusses
roof material: Oriented strand board
Ceiling structure: Trusses
Ceiling insulation material: Fiberglass loose fill
Roof ventilation type: Enclosed soffit vents
22) Insulation for the kitchen fan duct was falling down. Refer to builder for repair.
Limitations: The inspector does not operate circuit breakers as part of the inspection, and does not install or change light bulbs. The inspector does not evaluate every wall switch or receptacle, but instead tests a representative number of them per various standards of practice. When furnishings, stored items or child-protective caps are present some receptacles are usually inaccessible and are not tested; these are excluded from this inspection. Receptacles that are not of standard 110 volt configuration, including 240-volt dryer receptacles, are not tested and are excluded. The functionality of, power source for and placement of smoke and carbon monoxide alarms is not determined as part of this inspection. Upon taking occupancy, proper operating and placement of smoke and carbon monoxide alarms should be verified and batteries should be changed. These devices have a limited lifespan and should be replaced every 10 years. The inspector attempts to locate and evaluate all main and sub-panels. However, panels are often concealed. If panels are found after the inspection, a qualified electrician should evaluate and repair if necessary. The inspector attempts to determine the overall electrical service size, but such estimates are not guaranteed because the overall capacity may be diminished by lesser-rated components in the system. Any repairs recommended should be made by a licensed electrician.
Primary service type: Underground
Number of service conductors: 3
Service voltage (volts): 120-240
Estimated service amperage: 200
Primary service overload protection type: Circuit breakers
Service entrance conductor material: Stranded aluminum
Main disconnect rating (amps): 200
System ground: Ground rod(s) in soil
Location of main service panel #A: Building exterior
Location of main disconnect: Breaker at top of main service panel
Circuit breakers that were in the "off" position: Water heater
26) Exterior ceiling fan and what appeared to be a light fixture in the kitchen was inoperable (didn't turn on when nearby switches were operated). Recommend further evaluation by replacing bulbs and/or consulting with the property owner. If replacing bulbs doesn't work and/or no other switch(es) can be found, then recommend that a qualified electrician evaluate and repair or replace light fixtures as necessary.
Photo 26-1 Photo 26-2
Photo 26-3 Photo 26-4
27) The house meets current standards.
Current safety standards recommend smoke alarms should be installed in each bedroom, in hallways leading to bedrooms, and on each level. They have a limited lifespan and should be replaced every 10 years. Batteries in smoke alarms should be changed when taking occupancy and annually in the future. Carbon monoxide alarms should be installed near sleeping areas and on each level in homes with a fuel-burning appliance or attached garage. For more information, visit: http://www.reporthost.com/?SMKALRM http://www.reporthost.com/?COALRM
Limitations: The following items are not included in this inspection: private/shared wells and related equipment; private sewage disposal systems; hot tubs or spas; main, side and lateral sewer lines; gray water systems; pressure boosting systems; trap primers; incinerating or composting toilets; fire suppression systems; water softeners, conditioners or filtering systems; plumbing components concealed within the foundation or building structure, or in inaccessible areas such as below tubs; underground utilities and systems; overflow drains for tubs and sinks; backflow prevention devices. Any comments made regarding these items are as a courtesy only. Note that the inspector does not operate water supply or shut-off valves due to the possibility of valves leaking or breaking when operated. The inspector does not test for lead in the water supply, the water pipes or solder, does not determine if plumbing and fuel lines are adequately sized, and does not determine the existence or condition of underground or above-ground fuel tanks.
Water service: Public
Location of main water meter: By sidewalk in front of house
Location of main water shut-off: Pantry
Service pipe material: Plastic
Supply pipe material: PEX plastic
Drain pipe material: Plastic
Waste pipe material: Plastic
Vent pipe material: Plastic
Location of main fuel shut-off valve: At gas meter
Location of main fuel shut-off valve: By furnace
29) Insulation for some water supply pipes in the crawl space was substandard. Recommend replacing or installing insulation on pipes per standard building practices to prevent them from freezing during cold weather, and for better energy efficiency with hot water supply pipes.
Photo 29-1 Photo 29-2
Photo 29-3 Photo 29-4
Photo 29-5 Photo 29-6
Photo 29-7 Photo 29-8
Photo 29-9 Photo 29-10
30) Plumbing vent pipe above laundry room loose and freely moves up and down, refer to builder for repair.
Photo 30-1
31) Recommended the system being winterized soon.
Based on visible equipment, this property appeared to have a yard irrigation (sprinkler) system. These are specialty systems and are not a part of a typical home inspection. A recent backflow test tag was not visible. Backflow tests are required annually in many municipalities in our area to prevent cross-contamination of potable water. Recommend asking builder about test and obtaining work orders if available. If no test has been performed, recommend a qualified specialist perform a backflow test.
Photo 31-1 Photo 31-2
32) Water pressure taken at the house measured 80-85 PSI. Typical residential water pressure is 40 to 80 PSI.
Photo 32-1 Photo 32-2
33) One sewer clean out was noted at the front of the house.
Photo 33-1
34) Main water shutoff valve is located in pantry closet.
The main gas shut off valve is located at the gas meter at the side of the house.
35) The draft hood for the water heater flue was loose and section above on flue appeared not fully fastened . This is a potential safety hazard due to the risk of exhaust gases entering living spaces. Refer to builder to permanently secure the draft hood and flue with appropriate fasteners per standard building practices.
Photo 35-1 Photo 35-2
36) The water heater burner flames "popped" when burners ignited or shut down. This may be caused by gas pressure problems, dirty or defective burners, or burners out of adjustment. Recommend that a qualified contractor evaluate and repair as necessary.
The water heater burner flame was not blue in color. Various conditions can cause incorrect flames (not blue, noisy, floating) including incorrect drafting, dirty burner orifices and improper gas pressure. Refer to builder if problem persists.
Photo 36-1
37) Water temperature taken in the house was within the generally accepted range. Temperatures above 130 degrees increase scalding risk.
Maintaining your water heater for maximum life. See link for more information.
Limitations: The following items are not included in this inspection: humidifiers, dehumidifiers, electronic air filters; solar, coal or wood-fired heat systems; thermostat or temperature control accuracy and timed functions; heating components concealed within the building structure or in inaccessible areas; underground utilities and systems; safety devices and controls (due to automatic operation). Any comments made regarding these items are as a courtesy only. Note that the inspector does not provide an estimate of remaining life on heating or cooling system components, does not determine if heating or cooling systems are appropriately sized, does not test coolant pressure, or perform any evaluations that require a pilot light to be lit, a shut-off valve to be operated, a circuit breaker to be turned "on" or a serviceman's or oil emergency switch to be operated. It is beyond the scope of this inspection to determine if furnace heat exchangers are intact and free of leaks. Condensation pans and drain lines may clog or leak at any time and should be monitored while in operation in the future. Where buildings contain furnishings or stored items, the inspector may not be able to verify that a heat source is present in all "liveable" rooms (e.g. bedrooms, kitchens and living/dining rooms).
General heating system type(s): Forced air
General heating distribution type(s): Ducts and registers
Last service date of primary heat source: Brand new
Forced air heating system fuel type: Natural gas
Estimated age of forced air furnace: 2024
Forced air heating system manufacturer: Rheem
Location for forced air filter(s): At base of air handler
Type of combustion air supply: Vent(s) to exterior
Cooling system and/or heat pump fuel type: Electric
Type: Split system
Estimated age of heat pump or air conditioning unit: 2024
Manufacturer of cooling system and/or heat pump: Rheem
38) No serviceman's switch was visible for the furnace. This is a switch that allows power to be turned off quickly if something goes wrong when someone is performing maintenance or repairs. This is a potential safety hazard. Requirements vary by municipality, but general guidelines require the switch be within an arm's length of the appliance. In some cases the disconnect at the electric panel (e.g. circuit breaker or fuse) may suffice if it's within sight of the appliance. Recommend that a qualified contractor install a serviceman's switch per standard building practices.
Photo 38-1
39) Furnace and A/C were functioning at time of inspection.
Units are new, recommend annual servicing in the future for warranty purposes.
The filter should be changed upon move in. How often a filter should be changed depends on environmental factors (ie pets, smoking, dust, etc) but a general rule of thumb is every 3 months. Adjust time according to observation.
Limitations: The following items are not included in this inspection: coal stoves, gas logs, chimney flues (except where visible). Any comments made regarding these items are as a courtesy only. Note that the inspector does not determine the adequacy of drafting or sizing in fireplace and stove flues, and also does not determine if prefabricated or zero-clearance fireplaces are installed in accordance with the manufacturer's specifications. The inspector does not perform any evaluations that require a pilot light to be lit, and does not light fires. The inspector provides a basic visual examination of a chimney and any associated wood burning device. The National Fire Protection Association has stated that an in-depth Level 2 chimney inspection should be part of every sale or transfer of property with a wood-burning device. Such an inspection may reveal defects that are not apparent to the home inspector who is a generalist.
Gas fireplace or stove type: Metal pre-fab fireplace
Fan or blower installed in gas-fired fireplace or stove: Yes
Gas-fired flue type: Direct vent
40) Flue pipe sections or connections were loose and not connected at direct vent hood for fireplace. A qualified person should repair per standard building practices.
Photo 40-1 Photo 40-2
Photo 40-3
41) Gas fireplace was functional at time of inspection.
Recommend that the client review all available documentation for gas-fired fireplaces and stoves. Depending on how they are operated (for routine heating versus ambiance), such appliances may need servicing annually or every few years. Consult with the property owner and/or a qualified specialist to determine if service is needed now. Any needed repairs noted in this report should be brought to the attention of the specialist when it's serviced. For more information visit: http://www.reporthost.com/?ANGFINSP
Photo 41-1 Photo 41-2
42) The blower for the gas-fired fireplace or stove did not operate. The inspector did not determine why. This can be due to various reasons such as a switch that wasn't found, or a thermostat not reaching a high enough temperature. Consult with the property owner and review documentation for such appliances. If necessary, a qualified specialist should evaluate and repair.
Limitations: The following items are not included in this inspection: household appliances such as stoves, ovens, cook tops, ranges, dishwashers, refrigerators, freezers, ice makers, hot water dispensers and water filters; Any comments made regarding these items are as a courtesy only. Note that the inspector does not provide an estimate of the remaining life of appliances, and does not determine the adequacy of operation of appliances. The inspector does not note appliance manufacturers, models or serial numbers and does not determine if appliances are subject to recalls. Areas and components behind and obscured by appliances are inaccessible and excluded from this inspection.
Condition of sinks and related plumbing: Serviceable.
Condition of under-sink food disposal: Appears serviceable
Condition of dishwasher: Required repair, replacement and/or evaluation (see comments below)
Condition of range, cooktop or oven: Appears serviceable.
Condition of refrigerator: Appeared serviceable
43) The dishwasher was inoperable. Recommend that a qualified specialist evaluate and repair or replace as necessary.
Photo 43-1 Photo 43-2
Photo 43-3
44) One master bathroom drawer was difficult to close. Refer to builder for adjustment.
Photo 44-1 Photo 44-2
45) Inspector performs a limited function test of appliances and runs dishwasher for short cycle. Deficiencies at time of inspection are noted above if present.
Inspector removed dishwasher toe kick and no leaks were observed at time of inspection.
Limitations: The following items are not included in this inspection: overflow drains for tubs and sinks; heated towel racks, saunas, steam generators, clothes washers, clothes dryers. Any comments made regarding these items are as a courtesy only. Note that the inspector does not determine the adequacy of washing machine drain lines, washing machine catch pan drain lines, or clothes dryer exhaust ducts. The inspector does not operate water supply or shut-off valves for sinks, toilets, bidets, clothes washers, etc. due to the possibility of valves leaking or breaking when operated. The inspector does not determine if shower pans or tub and shower enclosures are water tight, or determine the completeness or operability of any gas piping to laundry appliances.
Location #A: Half bath
Location #B: Full bath
Location #C: Full bath, Master bath
Location #D: Laundry room/area
Condition of counters: Serviceable.
Condition of cabinets: Appeared serviceable
Condition of flooring: Satisfactory
Condition of sinks and related plumbing: Serviceable.
Condition of toilets: Serviceable.
Condition of bathtubs and related plumbing: Serviceable.
Condition of shower(s) and related plumbing: Serviceable.
Condition of ventilation systems: Satisfactory
46) Leaks were found at water supply lines for the sink at location(s) #B. A qualified plumber should repair as necessary.
Photo 46-1 Photo 46-2
47) Gaps, no caulk, or substandard caulking were found between the shower enclosure and the floor/walls at location(s) #B/C. Water can penetrate these areas and cause damage. Recommend that a qualified person re-caulk or install caulking as necessary.
Photo 47-1 Photo 47-2
Photo 47-3 Photo 47-4
Photo 47-5 Photo 47-6
Photo 47-7 Photo 47-8
Photo 47-9 Photo 47-10
Photo 47-11 Photo 47-12
Photo 47-13 Photo 47-14
48) We recommend when first running the dryer to confirm that it is blowing to exterior by observing exterior louvres.
Photo 48-1 Photo 48-2
49) No shower door was installed in master bathroom, refer to builder for options.
Photo 49-1 Photo 49-2
50) Inspector ran water in the sink(s) and bathtub(s). Ran shower water and flushed toilet(s).
Limitations: The following items are not included in this inspection: security, intercom and sound systems; communications wiring; central vacuum systems; elevators and stair lifts; cosmetic deficiencies such as nail-pops, scuff marks, dents, dings, blemishes or issues due to normal wear and tear in wall, floor and ceiling surfaces and coverings, or in equipment; deficiencies relating to interior decorating; low voltage and gas lighting systems. Any comments made regarding these items are as a courtesy only. Note that the inspector does not evaluate any areas or items which require moving stored items, furnishings, debris, equipment, floor coverings, insulation or similar materials. The inspector does not test for asbestos, lead, radon, mold, hazardous waste, urea formaldehyde urethane, or any other toxic substance. Some items such as window, drawer, cabinet door or closet door operability are tested on a sampled basis. The client should be aware that paint may obscure wall and ceiling defects, floor coverings may obscure floor defects, and furnishings may obscure wall, floor and floor covering defects. If furnishings were present during the inspection, recommend a full evaluation of walls, floors and ceilings that were previously obscured when possible. Determining the cause and/or source of odors is not within the scope of this inspection.
Type(s) of windows: Vinyl, Multi-pane, Sliding, Single-hung, Fixed
Wall type or covering: Drywall
Ceiling type or covering: Drywall
Condition of flooring: Satisfactory
Flooring type or covering: Laminate
51) The sliding glass door was difficult to open or close. Trim on the door was loose and keeping slider screen closed.
Photo 51-1 Photo 51-2
Photo 51-3
52) Staples underneath exterior door were scratching door jamb and was difficult to operate. Recommend that a qualified person repair as necessary.
Photo 52-1 Photo 52-2
Photo 52-3
53) Tile not finished around master toilet.
Gaps around tile and cabinets.
Gaps in flooring throughout house.
Refer to builder for options.
Photo 53-1 Photo 53-2
Photo 53-3 Photo 53-4
Photo 53-5 Photo 53-6
Photo 53-7 Photo 53-8
Photo 53-9 Photo 53-10
Photo 53-11 Photo 53-12
Photo 53-13 Photo 53-14
Photo 53-15 Photo 53-16
Photo 53-17 Photo 53-18
This report is not a guaranty or warranty. Anything can fail at any time. This inspection report is only reporting on the conditions as observed at the time of the inspection, and is not intended to be considered as a guaranty or warranty, expressed or implied, of the adequacy of, or performance of, systems or structures, or their component parts, or of their remaining life expectancy or usefulness. Systems, equipment and components can, and do, fail—randomly and without prior warning.
Please review your pre-inspection agreement
We appreciate the opportunity to be of service. Should you have any questions about the general condition of the house in the future, we would be happy to answer these. There is no fee for this telephone consulting. Our fees are based on a single visit to the property. If additional visits are required for any reason, additional fees may be assessed.