View as PDF

View summary

Green Apple Home Inspections

gahikw@gmail.com
(208) 703-2947

Thank you for choosing Green Apple Home Inspection, the following report lists out defects as well as general information found at this dwelling.

Client(s):  Paul and CJ Mulgrew
Property address:  5950 S Tallowtree Way
Boise ID 83716-6964
Inspection date:  Tuesday, December 11, 2018

This report published on Tuesday, December 11, 2018 4:18:52 PM MST

This report is the exclusive property of this inspection company and the client(s) listed in the report title. Use of this report by any unauthorized persons is prohibited.
This report is good only for the day of the inspection and cannot account for defects found after the inspection what the report states is what was seen at the time and day.
By continuing to read this report you agree to handling any objections or disagreements by writing within the first 30 days of the inspection report.
If no mutual agreement is reached, conflict resolution will be solved by arbitration only.
This report is not for resale, unless agreed upon by both the inspector and the client.

How to Read this Report
This report is organized by the property's functional areas.  Within each functional area, descriptive information is listed first and is shown in bold type.  Items of concern follow descriptive information. Concerns are shown and sorted according to these types:
Concern typeSafetyPoses a risk of injury or death
Concern typeMajor DefectCorrection likely involves a significant expense
Concern typeRepair/ReplaceRecommend repairing or replacing
Concern typeRepair/MaintainRecommend repair and/or maintenance
Concern typeMaintainRecommend ongoing maintenance
Concern typeEvaluateRecommend evaluation by a specialist
Concern typeMonitorRecommend monitoring in the future
Concern typeCommentFor your information
Concern typeConducive conditionsConditions conducive for wood destroying insects or organisms (Wood-soil contact, shrubs in contact with siding, roof or plumbing leaks, etc.)

Click here for a glossary of building construction terms.Contact your inspector If there are terms that you do not understand, or visit the glossary of construction terms at https://www.reporthost.com/glossary.asp

Table of Contents

General information
Exterior
Roof
Garage
Attic
Electric service
Water heater
Heating and cooling
Plumbing and laundry
Fireplaces, woodstoves and chimneys
Crawl space
Kitchen
Bathrooms
Interior rooms

View summary

General information
Table of contents
Report number: 10851
Type of building: Single family
Age of building: Around 19-20 years
Time started: 1030
Inspection Fee: $300
Payment method: Check
Present during inspection: Client(s)
Occupied: Yes
Weather conditions: Partly cloudy, Cloudy
Temperature: Cold
Ground condition: Wet, Damp, Frozen
Front of structure faces: West
Main entrance faces: East
Foundation type: Crawlspace
The following items are excluded from this inspection: Private sewage disposal system, Security system, Irrigation system, Swimming pool, Hot tub, Private well, Shed, Playground equipment, Sauna, Low voltage outdoor lighting, Central vacuum system, Water filtration system, Water softener system, Built-in sound system, Intercom system, Generator system, Sport court, Sea wall, Outbuildings
1) Some wall, floor and/or ceiling surfaces were obscured by furniture and/or stored items. Some areas couldn't be evaluated.
Footing material: Poured in place concrete
Foundation material: Poured in place concrete
Apparent wall structure:
Wall covering: Wood clapboard, Brick veneer
Driveway material: Poured in place concrete
Sidewalk material: Poured in place concrete
Exterior door material: Solid core steel, Solid core fiberglass, Sliding glass
2) One or more hornet, bee and/or wasp nests were found. These can pose a safety hazard. Nest(s) should be removed as necessary.
Photo
Photo 2-1 
3) Conducive conditionsThe perimeter grading slopes towards the structure in one or more areas. This can result in water accumulating around the structure's foundation, or in basements and crawl spaces if they exist. Accumulated water is a conducive condition to wood destroying insects and organisms. Wet soil may also cause the foundation to settle and possibly fail over time. Recommend grading soil so it slopes down and away from the structure with a slope of at least 5% (10% or better is optimal) for at least 6 feet.
Photo
Photo 3-1 
Photo
Photo 3-2 
4) Conducive conditionsOne or more downspouts are dented, damaged and/or crushed. This can restrict the water flow and result in clogging and overflowing gutters. Water may accumulate around the structure's foundation, or in basements and crawl spaces if they exist. Accumulated water is a conducive condition to wood destroying insects and organisms, and may also cause the foundation to settle and possibly fail over time. Damaged downspouts should be repaired or replaced as necessary, and by a qualified contractor if necessary. this was seen specifically in the back yard.
5) Conducive conditionsOne or more gutters were leaking during the inspection. This can result in water accumulating around the structure's foundation, or in basements and crawl spaces if they exist. Accumulated water is a conducive condition to wood destroying insects and organisms, and may also cause the foundation to settle and possibly fail over time. A qualified contractor should replace or repair gutters where necessary. this was seen in in the front entry area.
Photo
Photo 5-1 
6) Conducive conditionsOne or more crawlspace vents are below or near grade with no well to prevent rainwater from entering. This can lead to water entering and accumulating in the crawl space, and is a conducive condition for wood destroying insects and organisms. A qualified contractor should install wells where necessary.
Photo
Photo 6-1 
Photo
Photo 6-2 
7) Conducive conditionsOne or more minor cracks (1/8 inch or less) were found in the foundation. These don't appear to be a structural concern, but recommend sealing them to prevent water infiltration and monitoring them in the future. Numerous products exist to seal such cracks including:
Photo
Photo 7-1 
Photo
Photo 7-2 
Photo
Photo 7-3 
Roof inspection method: Viewed from eaves on ladder
Roof type: Gable
Roof covering: Asphalt or fiberglass composition shingles
Estimated age of roof: 19 years
Gutter & downspout material: Aluminum
Roof ventilation: Adequate
8) The roof was partially obscured by snow and couldn't be fully evaluated.
Photo
Photo 8-1 
Photo
Photo 8-2 
Photo
Photo 8-3 
Photo
Photo 8-4 
Photo
Photo 8-5 
9)  Be aware of ice damming potential on the northern and eastern facing side of the roof.
Photo
Photo 9-1 
Photo
Photo 9-2 
10) The interior perimeter of the garage is excluded from this inspection due to lack of access from stored items.
Photo
Photo 10-1 
Photo
Photo 10-2 
11) The garage was in good condition at the time of the inspection. However the inspection was limited by personal storage.
Inspection method: Partially traversed
Roof structure type: Trusses
Ceiling structure: Trusses
Insulation material: Fiberglass loose fill
Insulation depth: 12 inches
Insulation estimated R value: 38
12) The attic was in good dry condition at the time of the inspection.
Photo
Photo 12-1 
Photo
Photo 12-2 
Photo
Photo 12-3 
Photo
Photo 12-4 
Electric service
Table of contents
Primary service type: Underground
Primary service overload protection type: Circuit breakers
Location of main disconnect: Breaker at top of main service panel
System ground: Concrete encased electrode
Main disconnect rating (amps): 100
Branch circuit wiring type: Copper, Aluminum solid-strand
Solid strand aluminum branch circuit wiring present: Yes
Smoke detectors present: Yes
13) This home has solid-strand branch circuit aluminum wiring. This type of aluminum wiring is a potential fire hazard. Problems due to expansion and contraction can cause overheating at connections between the wire and devices such as switches and receptacles, or at splices. The Consumer Products Safety Commission recommends either discontinuing use of circuits with aluminum wiring, or pigtailing copper wiring onto the ends of the aluminum wire. A qualified electrician should evaluate and repair or replace this wiring. For more information, visit: http://www.inspect-ny.com/aluminum.htm
Photo
Photo 13-1 
14) The electrical panel was in good condition at the time of the inspection.
Photo
Photo 14-1 
Photo
Photo 14-2 
Water heater
Table of contents
Estimated age: 2 years
Type: Tank
Energy source: Natural gas
Capacity (in gallons): 50
Manufacturer: Rheem
15) The water heater was in good working condition at the time of the inspection.
Photo
Photo 15-1 
Heating and cooling
Table of contents
Estimated age: 18 years
Primary heating system energy source: Natural gas
Primary heat system type: Forced air
Distribution system: Flexible ducts
Manufacturer: Carrier
Filter location: In return air duct above furnace
16) Because of the age and/or condition of this furnace, recommend that a qualified heating and cooling technician inspect the heat exchanger and perform a Carbon Monoxide test when it's serviced.
17) The last service date of this system appears to be more than one year ago, or the inspector was unable to determine the last service date. The client(s) should ask the property owner(s) when it was last serviced. If unable to determine the last service date, or if this system was serviced more than one year ago, a qualified heating and cooling contractor should inspect, clean, and service this system, and make repairs if necessary. For safety reasons, and because this system is fueled by gas or oil, this servicing should be performed annually in the future. For more information visit: http://www.cpsc.gov/CPSCPUB/PREREL/prhtml05/05017.html
Photo
Photo 17-1 
Photo
Photo 17-2 
18) The estimated useful life for air conditioning compressors is 8 to 15 years. This unit appears to have exceeded this age and may need replacing at any time. Recommend budgeting for a replacement in the near future.
19) Air handler filter(s) should be checked monthly in the future and replaced or washed as necessary.
20) The outdoor air temperature was below 60 degrees Fahrenheit during the inspection. Because of this, the inspector was unable to operate and fully evaluate the cooling system.
21) The HVAC was in good working condition at the time of the inspection.
Photo
Photo 21-1 
Photo
Photo 21-2 
Plumbing and laundry
Table of contents
Location of main water shut-off valve: In Closet
Water service: Public
Supply pipe material: CPVC
Vent pipe material: Plastic
Drain pipe material: Plastic
Waste pipe material: Plastic
22) Conducive conditionsOne or more active leaks were found in drain and/or waste pipes or fittings. A qualified plumber should evaluate and repair as necessary. This was seen specifically the master shower drain pipe.
Photo
Photo 22-1 
Photo
Photo 22-2 
Photo
Photo 22-3 
23) The plumbing was in good working condition at the time of the inspection.
Fireplaces, woodstoves and chimneys
Table of contents
Fireplace type: Metal prefabricated
Chimney type: Metal
24) The fireplace was in good working condition at the time of the inspection.
Photo
Photo 24-1 
Crawl space
Table of contents
Inspection method: Traversed
Insulation material underneath floor above: Fiberglass roll or batt
Pier or support post material: Concrete
Beam material: Solid wood
Floor structure above: Engineered wood joists
Vapor barrier present: Yes
25) Conducive conditionsEvidence of prior water intrusion was found in one or more sections of the crawl space. For example, sediment stains on the vapor barrier or foundation, and/or efflorescence on the foundation. Accumulated water is a conducive condition for wood destroying insects and organisms and should not be present in the crawl space. The client(s) should review any disclosure statements available and ask the property owner(s) about past accumulation of water in the crawl space. The crawl space should be monitored in the future for accumulated water, especially after heavy and/or prolonged periods of rain. If water is found to accumulate, a qualified contractor who specializes in drainage issues should evaluate and repair as necessary. Typical repairs for preventing water from accumulating in crawl spaces include:
  • Repairing, installing or improving rain run-off systems (gutters, downspouts and extensions or drain lines)
  • Improving perimeter grading
  • Repairing, installing or improving underground footing and/or curtain drains

Ideally, water should not enter crawl spaces, but if water must be controlled after it enters the crawl space, then typical repairs include installing trenches, gravity drains and/or sump pump(s) in the crawl space.
26) The crawl space was in good dry condition at the time of the inspection.
Photo
Photo 26-1 
Photo
Photo 26-2 
27) All kitchen appliances were in good working condition at the time of the inspection.
28) The bathroom(s) and all the water sources were in good working condition at the time of the inspection.
Interior rooms
Table of contents
29) Squeaking or creaking noises occur when walking on one or more sections of flooring. This is usually caused by substandard construction practices where the subfloor decking is not adequately fastened to the framing below. For example, not enough glue was used and/or nails were used rather than screws. In most cases, this is only an annoyance rather than a structural problem. Various solutions such as Squeeeeek No More and Counter Snap fasteners exist to correct this. Repairs to eliminate the squeaks or creaks may be more or less difficult depending on the floor covering, and the access to the underside of the subfloor. Recommend having a qualified contractor evaluate and repair as necessary.
30) Lock mechanisms on one or more windows are damaged so that they are difficult to operate. Repairs should be made by a qualified contractor or service technician so that windows lock and unlock easily. This was seen specifically at the dining room sliding window.
Photo
Photo 30-1 
31) One or more light switches appear to be inoperable. Recommend further evaluation by consulting with the property owner(s). Repairs or replacement of light switch(s) by a qualified electrician may be necessary. This was seen specifically at the living room and the master bedroom.
32) Minor cracks were found in ceilings in one or more areas. They do not appear to be a structural concern, but the client(s) may wish to repair these for aesthetic reasons.
33) Minor cracks were found in walls in one or more areas. They do not appear to be a structural concern, but the client(s) may wish to repair these for aesthetic reasons.

Unless specifically included in the inspection, the following items and any related equipment, controls, electric systems and/or plumbing systems are excluded from this inspection: detached buildings or structures; fences and gates; retaining walls; underground drainage systems, catch basins or concealed sump pumps; swimming pools and related safety equipment, spas, hot tubs or saunas; whether deck, balcony and/or stair membranes are watertight; trees, landscaping, properties of soil, soil stability, erosion and erosion control; ponds, water features, irrigation or yard sprinkler systems; sport courts, playground, recreation or leisure equipment; areas below the exterior structures with less than 3 feet of vertical clearance; invisible fencing; sea walls, docks and boathouses; retractable awnings. Any comments made regarding these items are as a courtesy only