This report published on Saturday, January 4, 2025 9:39:34 AM EST
"No home is perfect. Keep things in perspective. Do not kill your deal over things that do not matter. It is inappropriate to demand that a seller address deferred maintenance, conditions already listed on the seller's disclosure or nit-picky items."
The above is an excerpt from Sell Your Home For More by Nick Gromicko.
Acceptance of this report and/or relying on the information within constitutes acceptance of the real estate inspection agreement limits for the client listed above even if the agreement is not signed. Reliance on a home inspection report that was originally performed for a different home buyer removes warranties. Home Inspections are not a pass/fail. The purpose is to identify the condition of the home as much as can be done at the time of the inspection. It is out of the scope of the home inspection to give estimates for repairs. We recommend that contractors be utilized prior to closing to provide repair estimates.
If you are not the person identified as the client above then you need to attain permission from the client above and you need to have your own home inspection completed.
It is not typical to request to remedy those items which are small maintenance items. Your real estate agent will be your best source to help determine which items (if any) are appropriate to request for correction or improvement
1) Safety, Comment - Structures built prior to 1979 may contain lead-based paint and/or asbestos in various building materials such as insulation, siding, and/or floor and ceiling tiles. Both lead and asbestos are known health hazards. Evaluating for the presence of lead and/or asbestos is not included in this inspection. The client(s) should consult with specialists as necessary, such as industrial hygenists, professional labs and/or abatement contractors for this type of evaluation.
2) Comment - The Basic Commercial Inspection was conducted according to International Standards of Practice for Inspecting Commercial Properties. The inspection, the Report, and its uses are strictly limited to the scope as described herein and as expressed in the agreement. The inspection is in no way intended to be a warranty or guarantee, express or implied, regarding the future use or operability of the building or its components.
3) Comment - The scope of service for this Basic Commercial Inspection includes the following: Walk-through survey to visually observe the subject property so as to obtain information on material systems and components for the purposes of providing a brief description and identifying physical deficiencies to the extent that they are easily visible and readily accessible. The focus is upon larger expense items, typically well above the $500-$1000 range
4) Comment - Photos are only a representative sample of conditions observed. There may be more than one area of concern not shown by photo
5) Comment - This is a reminder that inspections are not code inspections, zoning checks nor a check for permits. Most buildings more than only a few years old are not up to current codes due to codes changing over time. It is normal and expected for homes and buildings not to be "up to code". Codes themselves are subject to locations and interpretation.
Inspections are also not a pest/rodent inspection. It is not uncommon for critters to move into buildings when weather gets colder and/or there are food sources available. Keep food sources away and monitor always.
It is recommended that you get estimates for repairs prior to closing to fully understand the costs involved. Cost estimates are not part of the inspection. Our inspectors do not provide repairs so any estimate provided is very rough if given and should not be relied on due to large variations from contractors and materials.
Life expectancy of materials, appliances and systems is outside the scope of the inspection. Any information regarding this should not be relied upon due to variations of opinions from contractors and materials.
6) Comment - Issues that are considered cosmetic are not the goal of this report. For example, holes, stains, scratches, unevenness, not perfectly level or square, missing trim, paint and finish flaws or odors.
Inspections and inspection reports are not a guaranty of future performance or future functionality. The inspection company is not responsible for failure to properly maintain the property or damage that occurs or uncovered after taking possession.
7) Comment - Additional Inspector(s):
Jim Troth
8) - The purpose of the Basic Commercial Inspection is to determine the current condition of the improvements located on a parcel of commercial real estate, by performing a walk-through survey and conducting research. The goal is to identify and communicate physical deficiencies to the user. The term physical deficiencies means the presence of conspicuous defects or material deferred maintenance of a subject property's material systems, components, or equipment as observed during the field observer's walk-through survey.
9) Safety, Major Defect, Repair/Replace, Evaluate - Cracks, deterioration, leaning and/or bowing were found in retaining walls. Because of the height or proximity to foundations or property lines, a qualified structural engineer should evaluate to determine what repairs are necessary. Repairs should be made by a qualified contractor.
Photo 9-1
10) Safety, Major Defect, Repair/Replace - Loading docks/ ramps were damaged. Recommend evaluation and securing all loading docs to help ensure safety.
Photo 10-1 Photo 10-2
Photo 10-3 Photo 10-4
Photo 10-5 Photo 10-6
11) Safety, Major Defect, Evaluate - Observed damaged foundation / walls and supports in various areas. Recommend evaluation and repair/replacement to help ensure proper foundation support. Recommend evaluation prior to closing.
Cables used for diagonal bracing were also damaged
Photo 11-1 Photo 11-2
Photo 11-3 Photo 11-4
Photo 11-5 bowing Photo 11-6
Photo 11-7 bowing
12) Safety, Repair/Replace - Vehicle restraint systems were not observed for all but one in the rear of the building. These help to prevent trailers from pulling away unexpectedly. Recommend installing to help prevent loading dock accidents. https://www.ritehite.com/en/am/products/vehicle-restraints
Photo 12-1 The only trailer lock system observed.
13) Safety, Repair/Maintain, Evaluate - Stairs/walkways have settled. Recommend evaluation and repair. Consider slab jacking as a repair method to ensure proper slope away from the building and to help remove any trip hazards.
14) Safety, Repair/Maintain, Evaluate - Guardrails were loose and/or wobbly in one area(s). This is a safety hazard. Recommend evaluation and repairs as necessary, such as installing new fasteners or hardware, installing additional fasteners and/or installing additional railing components as necessary so they are securely attached.
Photo 14-1
15) Safety, Repair/Maintain - Stairs with more than two risers had no handrail installed. This is a safety hazard. Handrails should be installed and be graspable handrails that your hand can completely encircle at stairs where missing.
16) Major Defect, Repair/Replace, Evaluate - Major crack / bowing (more than 3/4 inch wide) was found in the foundation / wall. These appear to be a structural concern, and may indicate that settlement is ongoing. The client(s) are strongly advised to hire qualified contractors and/or engineers as necessary for further evaluation of all areas of foundation. Such contractors may include:
Foundation repair contractors who may prescribe repairs, and will give cost estimates for prescribed repairs
Masonry contractors who repair and/or replace brick veneer
Geotechnical engineers who attempt to determine if settlement is ongoing, and what the cause of the settlement is
Structural engineers who determine if repairs are necessary, and prescribe those repairs
Photo 16-1 Photo 16-2
Photo 16-3
17) Repair/Replace, Evaluate - Moderate cracking and / or bowing in was found in the foundation/wall. This may be a structural concern, and an indication that settlement is ongoing. The client(s) should consider hiring qualified contractors and/or engineers as necessary for further evaluation of all areas of the foundation. Such contractors may include:
Foundation repair contractors who may prescribe repairs, and will give cost estimates for prescribed repairs
Masonry contractors who repair and/or replace brick veneer
Geotechnical engineers who attempt to determine if settlement is ongoing, and what the cause of the settlement is
Structural engineers who determine if repairs are necessary, and prescribe those repairs
Photo 17-1 Photo 17-2
Photo 17-3 Photo 17-4
Photo 17-5 Photo 17-6
18) Repair/Replace, Evaluate - There are indications of past foundation repair. However, there are some significant signs of subsequent movement. Recommend a structural engineer and/or drainage specialist be consulted for re-evaluation and/or possible repairs.
Photo 18-1 Photo 18-2
Photo 18-3 Photo 18-4
Photo 18-5
19) Repair/Replace, Evaluate - Support columns had dents. Recommend evaluation and repairs if needed.
Photo 19-1 Photo 19-2
20) Repair/Replace - The perimeter grading sloped towards the structure in areas. This is a common find. This can result in water accumulating around the structure's foundation, or in basements and crawl spaces if they exist. Accumulated water is a conducive condition to wood destroying insects and organisms. Wet soil may also cause the foundation to settle and possibly fail over time. Recommend grading soil so it slopes down and away from the structure. The grade should drop at least 6 inches within the first 10 feet. Correct any negative slope of brick/concrete areas as well to direct water away from structure. https://homeinspectionsinohio.com/negative-grading/
Where the site does not allow for the necessary fall away from the structure, drains or swales could be used.
21) Repair/Replace - One downspout was dented, damaged and/or crushed. This can restrict the water flow and result in clogging and overflowing gutters. Water may accumulate around the structure's foundation, or in basements and crawl spaces if they exist. Accumulated water is a conducive condition to wood destroying insects and organisms, and may also cause the foundation to settle and possibly fail over time. Damaged downspouts should be repaired or replaced as necessary.
22) Repair/Replace - The cushions to help seal the "connection" between the back of a truck and the structure was missing or significantly deteriorated. Recommend installing.
23) Repair/Replace - One gutter(s) was/were damaged/missing. This can result in water accumulating around the structure's foundation, or in basements and crawl spaces if they exist. Accumulated water is a conducive condition to wood destroying insects and organisms, and may also cause the foundation to settle and possibly fail over time. Recommend replacing or repairing gutters where necessary.
24) Repair/Replace - Bumper designed to protect the dock was missing and deteriorated in area. Recommend installing to help absorb vehicle impacts to protect the docks.
Photo 24-1 Photo 24-2
Photo 24-3 Photo 24-4
25) Repair/Maintain - Minor cracks (1/8 inch or less) were found in the foundation. These don't appear to be a structural concern, but recommend sealing them to help prevent water infiltration and monitoring them in the future. Numerous products exist to seal such cracks including:
Hydraulic cement. Requires chiseling a channel in the crack to apply.
Resilient caulks (easy to apply).
Epoxy sealants (both a waterproof and structural repair).
Note: small cracks can be the result of normal drying and shrinking of cement and mortar along with settling.
Photo 25-1 Photo 25-2
26) Repair/Maintain - One downspout was missing. This can result in water accumulating around the structure's foundation, or in basements and crawl spaces if they exist. Accumulated water is a conducive condition to wood destroying insects and organisms and may also cause the foundation to settle and possibly fail over time. A qualified contractor should install downspout(s) where missing. Also recommend installing extensions such as splash blocks or tie-ins to underground drain lines as necessary to carry rainwater away from the structure.
27) Repair/Maintain - Gutters were leaking during the inspection. This can result in water accumulating around the structure's foundation, or in basements and crawl spaces if they exist. Accumulated water is a conducive condition to wood destroying insects and organisms, and may also cause the foundation to settle and possibly fail over time. Recommend repairing gutters where necessary.
28) Repair/Maintain - Bollard(s) were missing in areas that would benefit from the protection of them. Consider installing where needed.
Photo 28-1 Photo 28-2
29) Comment - The following items are not included in this inspection: swimming pools, spas, hot tubs, water features and related equipment; playground, recreation or leisure equipment; landscape lighting; areas below exterior structures with less than three feet of vertical clearance; irrigation systems; invisible fencing; sea walls, docks and boathouses. Exterior buildings such as sheds, barns and garages are not included unless specifically requested. Any comments made regarding these items are as a courtesy only. Note that the inspector does not test or determine the adequacy of drainage systems for grounds, walkways, below-grade stairs and roof downspouts. The inspector does not provide an evaluation of geological conditions and/or site stability, compliance of pool or spa fencing with municipal requirements, or determination that deck, balcony and/or stair membranes are watertight. Inspector is unable to determine condition of underlying materials (see through solid objects) such as materials behind siding and facia positioned behind gutters or flashing for examples.
30) Comment - There are indications of past foundation repair such as installed I-beams, straps, anchors, etc. We recommend you refer to any structural engineer's report if available for further information of repairs, any warranties and proper maintenance of the foundation.
Photo 30-1 Photo 30-2
Photo 30-3 Photo 30-4
Photo 30-5 Photo 30-6
31) - The following items are not included in this inspection: below-grade foundation walls and footings, or those obscured by vegetation or building components; exterior building surfaces or components obscured by vegetation, stored items or debris. Any comments made regarding these items are as a courtesy only. Some amount of cracking is normal in concrete slabs and foundation walls due to shrinkage and drying. Note that the inspector does not determination the adequacy of sump pumps, seismic reinforcement, take measurements of plumbness, nor determine if support posts, columns, beams, joists, studs, trusses, etc. are of adequate size, spanning or spacing.
32) Safety, Repair/Replace, Evaluate - Significant amounts of contaminants or foreign material such as dirt and/or debris were found in the main service panel. No approved method exists for cleaning contaminants from panel interiors or components such as bus or terminal bars. The panel and/or components inside may need replacing. A qualified electrician should evaluate and repair or replace components as necessary.
Photo 32-1 Photo 32-2
33) Safety, Repair/Replace, Evaluate - Loose conductors were found in the main service panel had bare ends and were not connected to circuit breakers or fuses. This is a safety hazard due to the risk of fire if the bare conductors come into contact with other components in the panel. An electrician should evaluate and repair as necessary. For example, removing wires that aren't terminated or installing wire nuts.
Panel 2,11,5
Photo 33-1 Photo 33-2
Photo 33-3 Photo 33-4
Photo 33-5
34) Safety, Repair/Replace, Evaluate - Neutral wires were doubled or bundled with other conductors on the neutral bus bar in the Panel 12,5. Neutral wires should each have their own terminal and not placed together. This is unsafe due to the need to turn off multiple circuit breakers to work on any of the circuits using these wires. A qualified electrician should evaluate and repair as necessary.
If a neutral wire is bundled with a ground, it is considered a lesser concern and very common for buildings prior to 2002 typically.
Photo 34-1 Photo 34-2
35) Safety, Repair/Replace, Evaluate - One open ground, three-pronged grounding type receptacle(s) were found. This is a safety hazard due to the risk of shock. An electrician should evaluate and make repairs as necessary.
Grounding type receptacles were first required in structures during the 1960s. Based on the age of this structure and/or the absence of 2-pronged receptacles, repairs should be made by correcting wiring circuits as necessary so all receptacles are grounded as per standard building practices. Replacement of three-pronged receptacles with 2-pronged receptacles is not an acceptable solution.
Photo 35-1
36) Safety, Repair/Replace, Evaluate - Two electric receptacle had reverse-polarity wiring, where the hot and neutral wires are reversed. This is a safety hazard due to the risk of shock. An electrician should evaluate and make repairs as necessary.
identified with blue dot(s) with "H&N"
Photo 36-1
37) Safety, Repair/Replace, Evaluate - At least three sections of wiring that was not terminated was found. This is a potential safety hazard due to the risk of shock. A qualified electrician should evaluate and repair as necessary. For example, cutting the wire to length and terminating the wire with wire nuts in a securely anchored, covered, properly sized junction box.
Photo 37-1 Photo 37-2
Photo 37-3
38) Safety, Repair/Replace, Evaluate - Wire splices were exposed due to not being contained in a covered junction box or in a box that had no cover. This is a safety hazard due to the risk of shock and fire. A qualified electrician should evaluate and make repairs as necessary. For example, install securely mounted junction boxes and/or cover plates where needed to contain wiring splices.
Photo 38-1 Photo 38-2
Photo 38-3
39) Safety, Repair/Replace, Evaluate - Interlocking three single-pole breakers together to create a "3-pole" breaker is generally not considered acceptable practice as it could be an electrical safety hazard and potentially compromise the circuit protection. If one of the "3 pole breakers" circuits were to trip, that one breaker may not be strong enough to trip the other two.
Recommend a qualified licensed electrician install a proper three pole breaker that is designed for that type of 3 phase circuit, and/or removing if not needed any longer.
Photo 39-1 Photo 39-2
40) Safety, Repair/Maintain, Evaluate - Three electric receptacle(s) and/or the boxes they are installed in were loose and/or not securely anchored. Wire conductors may be damaged due to repeated movement and/or tension on wires, or insulation may be damaged. This is a safety hazard due to the risk of shock and fire. A qualified electrician should evaluate and repair as necessary.
Photo 40-1 Photo 40-2
Photo 40-3
41) Safety, Repair/Maintain, Evaluate - Non-metallic sheathed wiring was routed so it is subject to damage, such as on wall or ceiling surfaces. The insulation can be damaged by objects coming in contact with it and/or it being repeatedly moved. This is a safety hazard due to the risk of shock and fire. Recommend improving as necessary. For example, rewire using conduit, or re-routing through wall cavities.
Photo 41-1
42) Safety, Minor Defect - Knockout(s) had been removed inside the main service panel where no wires and bushings are installed, and no cover(s) have been installed to seal the hole(s). This is a safety hazard. Recommend installing knockout covers where missing.
Photo 42-1 Photo 42-2
Photo 42-3 Photo 42-4
43) Safety, Minor Defect - Pointed and/or too-long screws were used to fasten the cover to several panels. These types of screws are more likely to come into contact with wiring inside the panel than stock screws from the manufacturer, and can damage wiring insulation. This is a safety hazard due to the risk of shock and/or fire. Long and/or pointed crews should be replaced as necessary with the correct screws.
Photo 43-1 Photo 43-2
Photo 43-3
44) Safety, Minor Defect - Cover plates were missing for at least two electric box(s), such as for receptacles, switches and/or junction boxes. They are intended to contain fire and prevent electric shock from exposed wires. Cover plates should be installed where missing.
Photo 44-1
45) Safety, Minor Defect - Cover plate(s) were broken at three electric boxes, such as for receptacles, switches and/or junction boxes. They are intended to contain fire and prevent electric shock from exposed wires. This is a safety hazard due to the risk of fire and shock. Cover plates should be replaced where necessary.
Photo 45-1 Photo 45-2
Photo 45-3
46) Safety, Minor Defect - Conduit for protecting wires were not loose or not secured properly at the ends. Consider improving to help protect wires. Typically conduit should be secured with in 3 feet of panels/ends.
Photo 46-1 Photo 46-2
Photo 46-3
47) Repair/Replace, Evaluate - Office areas electric receptacle(s) did not have power. Recommend asking the property owner(s) about this. Switches may need to be operated to make some receptacles energized. If necessary, a qualified electrician should evaluate and make repairs as necessary.
identified with blue dot(s)
Photo 47-1
48) Serviceable, Comment - No observable concerns with the electric panel wiring.
Photo 48-1 Photo 48-2
Photo 48-3 Photo 48-4
Photo 48-5 Photo 48-6
49) Comment - The following items are not included in this inspection: generator systems, surge suppressors, inaccessible or concealed wiring condition or materials; underground utilities and systems; low voltage lighting or lighting on timers or sensors. Any comments made regarding these items are as a courtesy only. Note that the inspector does not determine the adequacy of grounding or bonding, does not determine if this system has an adequate capacity for the client's specific needs, nor determine if this system has any reserve capacity for additions or expansion. The inspector does not operate circuit breakers as part of the inspection, install or change light bulbs, nor determine the operability of every wall switch or outlet. Inspectors do not remove outlet covers and are unable to determine the type of wiring inside walls or in concealed spaces. Inspection are not code inspections.
Note: National safety standards require electrical panels to be weatherproof, readily accessible, and have a minimum of thirty-six inches of clear space in front of them for service. Also, they should have a main disconnect, and each circuit within the panel should be clearly labeled. Industry standards only require us to test a representative number of accessible switches, receptacles, and light fixtures. However, we attempt to test every one that is unobstructed, but if a building is furnished we will obviously not be able to test each one.
50) Safety, Repair/Replace, Evaluate - The furnace or boiler flame(s) are noisy (roaring) and/or "dancing" over the burner(s). This may be caused by an improper gas-air mixture flow velocity and may result in Carbon Monoxide due to incomplete combustion. A qualified heating and cooling contractor should evaluate and repair as necessary.
Photo 50-1 Photo 50-2
51) Repair/Replace, Evaluate - The cooling fins on air handler's evaporator coils are bent, damaged and/or deteriorated. This may result in reduced efficiency and higher energy costs. A qualified heating and cooling contractor should evaluate and repair as necessary.
Photo 51-1 Photo 51-2
52) Repair/Replace, Evaluate - One furnace did not respond when its controls were operated. This system was not fully evaluated. The client(s) should consult with the property owner(s) as to how it operates and have a qualified heating and cooling contractor evaluate and make repairs if necessary.
Photo 52-1
53) Maintain, Evaluate, Comment - The estimated useful life for forced air furnaces is 15 to 20 years. This furnace was at this age or older and may need replacing at any time. Recommend budgeting for a replacement in the near future. Recommend also servicing and prior to closing.
Periodic maintenance will help ensure continued operation.
54) Maintain, Comment - The estimated useful life for air conditioning compressors is 8 to 15 years. This unit was at this age or older and may need replacing at any time. Recommend budgeting for a replacement in the near future.
Periodic maintenance will help ensure continued operation.
55) Maintain - The filter(s) for the heating/cooling system should be checked monthly and replaced or washed as necessary.
Also be aware that heating and cooling systems should have regular maintenance on them yearly to help ensure long life spans.
56) Monitor, Comment - Stains observed on the exhaust vent. It appears that there may have been repairs such as sealing any gaps on the exterior. It is also possible that the stains can be caused by the exhaust fumes cooling and condensing. Monitor.
Photo 56-1
57) Monitor - Rust/stains observed in/on the furnace cabinet. Active leaking did not occur during time of inspection. Recommend monitoring for leaks from condensation.
If leaks do develop then get it evaluated and repaired to help prevent rusting/deterioration of the furnace.
Photo 57-1 Photo 57-2
58) Comment - We check heating and cooling for basic function. Our inspection is not technically exhaustive. Our inspection of ducts is naturally limited to observable areas. Therefore large areas of ducts cannot be seen. Since dirt, dust, mold, even toys are commonly found in ducts we recommend that you have the ducts cleaned.
61) Repair/Maintain, Evaluate - Drain line was not capped or was capped in a non standard manner. Recommend improving to help prevent sewer gases from escaping.
Odor of sewer gas in the was noted. Recommend evaluation and corrections made as needed by a plumber.
Photo 61-1
62) Comment - The following items are not included in this inspection: private wells and sewage disposal systems; main, side and lateral sewer lines; gray water systems; pressure boosting systems; incinerating or composting toilets; fire suppression sprinkler systems; water softeners, conditioners or filtering systems; plumbing materials / components concealed within the foundation or building structure, or in inaccessible areas such as below tubs; underground utilities and systems; overflow drains for tubs and sinks; backflow prevention devices. Any comments made regarding these items are as a courtesy only.
Note that the inspector is not required to operate water supply or shut-off valves due to the possibility of valves leaking or breaking when operated. The inspector does not test for lead in the water supply, the water pipes or solder, does not determine if plumbing and fuel lines are adequately sized, and does not determining the existence or condition of underground or above-ground fuel tanks.
63) Comment - "In accordance with industry standards, we do not normally test washing machines and their water connections and drainpipes if present. However, there are a few things of which you should be aware. The water supply to washing machines is usually left on, and their hoses can leak or burst under pressure and continue to flow. Therefore, we recommend replacing the rubber hose type with newer, braided, stainless steel ones that are much more dependable and that they be operated only during times you will be present. You should also be aware that the newer washing machines discharge a greater volume of water than many of the older drainpipes can handle, which causes the water to back up and overflow, and the only remedy would be to replace the standpipe and trap with one that is larger. Although not required, whenever structural damage may result from an overflow, we recommend a pan with a plumbed drain. An alternative is a flood or leak detection device that will terminate the water supply in a water pipe failure."
64) Comment - It is beyond the scope of the inspection to confirm if the structure uses a septic or a public sewer system. This includes determination or inspection of aerators designed for septic systems. Recommend confirming with seller if there is any questions regarding this. It is always a great idea to have the county health department inspect any septic system.
65) Comment - Your water meter and main water shut off location.
Photo 65-1
66) Comment - Image of water heater and data plate
67) Repair/Replace, Evaluate - Deteriorated raised concrete floor sections observed. Recommend correction to help remove trip hazards. Correct any conditions that could lead to settlement.
Photo 67-1 Photo 67-2
68) Repair/Replace, Evaluate - Seals between double-pane glass in one window(s) had failed based on condensation or stains between at least one of the panes of glass. A qualified contractor should evaluate entire window and replace glass where necessary.
The client(s) should be aware that evidence of aging seals may be more or less visible from one day to the next depending on the temperature, humidity, sunlight, etc. Windows or glass doors other than those that the inspector identified may also have failed seals and need glass replaced too.
69) Repair/Replace - Active roof leaks were observed recommended repair
70) Repair/Replace - Active roof leaks were observed throughout. Recommended repair
Photo 70-1 Photo 70-2
Photo 70-3 Photo 70-4
71) Repair/Maintain, Evaluate - Ceiling panel/tile was deteriorated/damaged. Recommend evaluation and repairs/replacements as needed.
Photo 71-1 Photo 71-2
Photo 71-3 Photo 71-4
Photo 71-5
72) Repair/Maintain - Damage/cracks were found in walls in areas. They do not appear to be a structural concern, but the client(s) may wish to repair these for aesthetic reasons. Areas:
Photo 72-1 Photo 72-2
73) Minor Defect, Maintain, Comment - Minor cracks were found in the concrete slab. However, they don't appear to be a structural concern and no trip hazards were found. This is common for large sections of cement. Recommend sealing to help prevent water infiltration and for aesthetic reasons.
Photo 73-1 Photo 73-2
Photo 73-3 Photo 73-4
74) Minor Defect, Maintain - The weatherstrip around the entry door was missing/deteriorated or had gaps to allow air leakage or water infiltration. Weatherstrip should be installed where missing and/or replaced where needed.
Photo 74-1
75) Monitor - Stains were found in drop ceiling area(s). However, no elevated levels of moisture were found. The stain(s) may be due to past roof and/or plumbing leaks. Recommend asking the property owner(s) about this, and monitoring the stained area(s) in the future, especially after heavy or prolonged rain.
76) Repair/Replace - The vehicle doors were damaged or deteriorated. A qualified contractor should evaluate and repair or replace the doors as necessary.
Door D H
Photo 76-1 Photo 76-2
Photo 76-3
77) Repair/Maintain, Minor Defect - One roller was out of the track, repair/reposition to help ensure smooth and proper operation.
Door d
78) Repair/Maintain, Evaluate - The vehicle doors were not balanced. The doors won't stay in place when it's partially opened. Recommend correction/tightening of the spring/tension-er.
79) Repair/Maintain - The track for the garage door was damaged/bent. Recommend evaluation and repairs as needed.
Door c
Photo 79-1
80) Repair/Maintain - Weatherstrip at the sides and/or bottom of the vehicle doors were damaged and/or deteriorated. They should be replaced where necessary to prevent water and small animal intrusion.
81) Repair/Maintain - Bollard was damaged / loose. Recommend repairing to help protect the the opening space edges.
Photo 81-1
82) Minor Defect, Monitor, Comment - The garage vehicle door had some small areas of deterioration/dents. Still operational, monitor.
83) Major Defect, Repair/Replace, Evaluate - The roof surface material is beyond or at the end of its service life and needs replacing now. The client(s) should consult with a qualified roofing contractor to determine replacement options and costs.
84) Repair/Replace, Evaluate - Ventilation was substandard in the attic. Inadequate attic ventilation may result in high attic and roof surface temperatures, reduce the life of the roof covering materials and increase cooling costs. High levels of moisture are also likely, and can be a conducive condition for wood destroying insects and organisms. Standard building practices require one square foot of vent area for 150 to 200 square feet of attic space. Vents should be evenly distributed between soffits, ridges and at corners to promote air circulation. Recommend correction/improvement.
85) Repair/Replace, Evaluate - Standing water was found on the flat roof. It should evaporate within 48 hours after it rains. If standing water remains after 48 hours, then the roof installation is likely substandard. A qualified roofing contractor should evaluate and repair if necessary to prevent prolonged standing water.
Photo 85-1 Photo 85-2
Photo 85-3 Photo 85-4
Photo 85-5 Photo 85-6
86) Repair/Replace, Evaluate - Flashings at parapet walls were deteriorated and/or substandard. These may result in leaks. A qualified roofing contractor should evaluate and repair as necessary.
Photo 86-1 Photo 86-2
87) Repair/Replace, Evaluate - Area(s) of the roof structure over the bathrooms was wet or had elevated levels of moisture at the time of the inspection. This indicated an active leak in the roof or structure exterior. A qualified contractor should evaluate and repair as necessary.
Photo 87-1 Photo 87-2
88) Repair/Replace, Evaluate - Ceiling insulation above the bathroom was uneven in some areas. The ceiling insulation's R rating was also less than what's recommended for this area (R30). Recommend installing additional insulation as per standard building practices for better energy efficiency.
Older buildings often have R below 13 while recently built buildings have higher R factors of typically 36 to 49 as result of standards changing over time. We consider R factor of 30 to be the minimum. Adding additional insulation would be considered an upgrade and you should calculate the return on the investment as it will likely take several years to get a return.
Photo 88-1 Photo 88-2
Photo 88-3
89) Repair/Replace, Evaluate - Truss/rafter has been bent/damaged. These should not be altered without a structural engineer approval of the changes. Recommend evaluation and repair.
Photo 89-1 Photo 89-2
Photo 89-3
90) Repair/Replace, Evaluate - Sag/soft areas were located. Recommend evaluation and repair/support as needed.
Photo 90-1
91) Repair/Replace, Evaluate - Gaps were found in many roof surface seams. These may result in leaks. Recommend evaluation and repair/sealing as necessary. Areas of previous repairs are in poor condition and should be evaluated for likely replacement.
Photo 91-1 Photo 91-2
Photo 91-3 Photo 91-4
Photo 91-5
92) Repair/Replace - Rubber roof had damaged in several areas. Recommend repair/patching to help prevent water infiltration.
Photo 92-1 Photo 92-2
Photo 92-3 Photo 92-4
Photo 92-5 Photo 92-6
Photo 92-7 Photo 92-8
Photo 92-9 Ventilation cap held down with bungee cord. Photo 92-10
Photo 92-11
93) Repair/Replace - Ventilation cap was missing. Replace or repair the roof as needed.
Photo 93-1
94) Evaluate, Comment - Unable to estimate insulation level due to design. Recommend asking sellers for information.
95) Evaluate - There were indications of a fire occurring. Recommend asking sellers for information and for any reports regarding this.
Photo 95-1 Photo 95-2
Photo 95-3 Photo 95-4
Photo 95-5
96) Comment - Be aware that lifting and or moving around insulation is beyond the scope of the inspection, therefore the areas directly buried and under insulation are not visible. Due to attic structures access to some areas are limited due to physical spaces and safety.
97) Comment - No accessible attic spaces were found or inspected at this property for most of the building
98) Comment - The following items or areas are not included in this inspection: areas that could not be traversed or viewed clearly due to lack of access; areas and components obscured by insulation; solar roofing components; any comments made regarding these items are as a courtesy only. Note that the inspector does not determination if rafters, trusses, joists, beams, etc. are of adequate size, spanning or spacing. The inspector does not provide an estimate of remaining roof surface life nor any guarantee of roofs age, does not determine that the roof has absolutely no leaks at the time of the inspection, and does not determine that the roof won't leak in the future. To absolutely determine than no leaks exist, complete access to all roof structure areas must be available during a wide variety of weather conditions, including prolonged heavy rain, high wind from varying directions, heavy accumulations of snow and/or ice, and melting snow and ice. We also recommend asking sellers for verification of roof covering age for all roof surfaces and/or checking building permits.
Insurance companies may or may not provide coverage due to a roofs age or other reasons of theirs. Recommend checking with your insurance provider regarding coverage. This is outside the scope for an inspector to know.
99) Safety, Repair/Replace - Fire extinguishers were missing.
Recommend correction.
Photo 99-1
100) Safety, Repair/Maintain, Evaluate - Inspected for exit signs at all exits and inspected for independent power sources such as batteries.
The presence of directional signs that were self powered where exit location was not obvious. Recommend evaluation and improvements as needed.
Photo 100-1
101) Comment - Recommend asking building owner and or the person in charge of maintenance for the records of health and safety inspections from the local jurisdiction.
102) Comment - A fire sprinkler system was present. These systems should be inspected annually.
Photo 102-1 Photo 102-2
103) - Slow leak observed at fire suppression system. Zone 3
Photo 103-1 Photo 103-2
104) - Damaged exit sign
Photo 104-1
Photo X-1 Photo X-2
Photo X-3
IMPORTANT INFORMATION CONTINUES You should not regard this inspection and report as a guarantee or warranty of the property and its components. It is not. It is simply a report on the general condition of the property at a given point in time. Furthermore, as a homeowner, you should expect problems to occur; roofs will leak, drain pipes will become blocked, and components and systems will fail without warning. For these reasons, you should take into consideration the age of the house and its components and keep a comprehensive insurance policy current. If you have been provided with a home protection policy, read it carefully. Such policies usually only cover insignificant costs, such as that of rooter service, and the representatives of some insurance companies are very likely to charge you for a service call and then deny coverage on the grounds that a given condition was preexisting or not covered because of an alleged code violation or a manufacturers defect. Therefore, you should read such policies very carefully, and depend upon our company for any assistance and consultation that you may need. It is highly recommended that the suggested repairs, corrections, evaluations, etc be done prior to the end of your due diligence time period if possible or before closing. Evaluations and repairs can reveal issues not visible during a home inspection or beyond the scope of a home inspection.
It is beyond the scope of the inspection to confirm if the structure uses a septic or a public sewer system. Recommend confirming with seller.
Heating and Cooling systems Furnaces typically will last 15-20 years. With proper maintenance they can last longer. Air conditioners also have a typical life expectancy of 8-15 years. Heat pumps typically last 15-20 years. The estimated useful life for boiler system is 25-40 years. It is normal to have issues with systems as they age. Be sure to have regular maintenance done.
As of January 2006, air conditioning manufacturers are no longer allowed to manufacture products, or certain individual components (condensers, evaporator, compressors) for systems with less than a 13 SEER rating. As existing inventories of older efficiency style components are depleted, replacement of the A/C unit may be required in place of repairs.
Note: R22 has been the standard refrigerant used in air conditioners for many years. The problem with this refrigerant is that it is both less efficient and less environmentally friendly than R410a refrigerant. The government-mandated shift away from R22 refrigerant is an attempt to make homes more efficient and reduce the emissions of greenhouse gasses into the environment. As of 2010 R22 is no longer allowed to be used in newly-manufactured air conditioners. R-22 can not be added to current systems after Jan 2019. MO99 is a refrigerant that can be used to replace R-22. Identifying the type of refrigerant used in a system is not within the scope of the home inspection.
Crawl Spaces Crawl spaces should all be viewed periodically. Although not desirable it is common for moisture levels to be higher here than in other areas of the home. Recommend quarterly viewing so as to catch water intrusion and moisture related issues quickly.
Roof materials It is beyond the scope of the inspection to give the life expectation of roofing materials. There are many factors that effect the aging process such as color, angle, orientation, ventilation and type of material. Any mention of age is a rough estimate based upon experience and is in no way an guarantee of the actual age. We recommend asking seller if you want specific age information. It is also beyond the scope to determine if a roof has more than one layer of materials. lower layer can be concealed by drip edges and flashings.
Roofs are designed to shed water like an umbrella and are not “waterproof”. In events of wind driven rains, and periods of intense rain, water can sometimes blow into areas such as ridge vents, roof vents and valleys and present leaking conditions. This occurrence is rare, but can possibly happen in severe storm events. Unless it is raining at the time of inspection, some roof leaks may not be identified during the inspection process. As prescribed in the inspection authorization and agreement, this is a visual inspection only. Roofing life expectancies can vary depending on several factors. Any estimates of remaining life are approximations only.
Ceiling fans cannot be checked for proper mounting inside attic spaces where concealed by insulation.
The accuracy of breaker labeling is beyond the scope of the inspection.
Rodents Please be aware that inspecting for rodents is outside the scope of home inspections. If we see obvious indications of activity we will note it. If we note it that should not be taken that we conducted a pest inspection. It is also very common for mice and similar sized critters to enter all homes at sometime. Please do not be alarmed if you have such house guests at sometime.
What are Molds? Molds are simple, microscopic organisms, present virtually everywhere, indoors and outdoors. Molds, along with mushrooms and yeasts, are fungi and are needed to break down dead material and recycle nutrients in the environment. For molds to grow and reproduce, they need only a food source and any organic material, such as leaves, wood, paper, or dirt and moisture. Because molds grow by digesting the organic material, they gradually destroy whatever they grow on. Sometimes, new molds grow on old mold colonies. Mold growth on surfaces can often be seen in the form of discoloration, frequently green, gray, brown, or black but also white and other colors. Molds release countless tiny, lightweight spores, which travel through the air. Everyone is exposed to some mold on a daily basis without evident harm. It is common to find mold spores in the air inside homes, and most of the airborne spores found indoors come from outdoor sources. Mold spores primarily cause health problems when they are present in large numbers and people inhale many of them. This occurs primarily when there is active mold growth within home, office or school where people live or work. People can also be exposed to mold by touching contaminated materials and by eating contaminated foods. Molds produce health effects through inflammation, allergy, or infection. Allergic reactions (often referred to as hay fever) are most common following mold exposure. Typical symptoms that mold-exposed persons report (alone or in combination) include: Respiratory problems, such as wheezing, difficulty breathing, and shortness of breath Nasal and sinus congestion, Eye irritation (burning, watery, or reddened eyes) Dry, hacking cough, Nose or throat irritation, Skin rashes or irritation Headaches, memory problems, mood swings, nosebleeds, body aches and pains, and fevers are occasionally reported in mold cases, but their cause is not understood. Molds will grow and multiply whenever conditions are right and sufficient moisture is available and organic material is present. Be on the lookout in your home for common sources of indoor moisture that may lead to mold problems: If you suspect that you may have mold, contact a specialist.
When Things Go Wrong There may come a time that you discover something wrong with the house, and you may be upset or disappointed with your home inspection.
Intermittent Or Concealed Problems. Some problems can only be discovered by living in a house. They cannot be discovered during the few hours of a home inspection. For example, some shower stalls leak when people are in the shower, but do not leak when you simply turn on the tap. Some roofs and basements only leak when specific conditions exist. Some problems will only be discovered when carpets were lifted, furniture is moved or finishes are removed.
No Clues. These problems may have existed at the time of the inspection but there were no clues as to their existence. Our inspections are based on the past performance of the house. If there are no clues of a past problem, it is unfair to assume we should foresee a future problem.
We Always Miss Some Minor Things Some might say we are inconsistent because our reports identify some minor problems but not others. The minor problems that are identified were discovered while looking for more significant problems. We note them simply as a courtesy. The intent of the inspection is not to find the $200 problems; it is to find the $2,000 problems. These are the things that affect people's decisions to purchase.
Contractors' Advice The main source of dissatisfaction with home inspectors comes from comments made by contractors. Contractors' opinions often differ from ours. Don't be surprised when three roofers all say the roof needs replacement when we said that, with some minor repairs, the roof will last a few more years.
Last Man In Theory While our advice represents the most prudent thing to do, many contractors are reluctant to undertake these repairs. This is because of the "Last Man In Theory". The contractor fears that if he is the last person to work on the roof, he will get blamed if the roof leaks, regardless of whether the roof leak is his fault or not. Consequently, he won't want to do a minor repair with high liability when he could re-roof the entire house for more money and reduce the likelihood of a callback. This is understandable.
Most Recent Advice Is Best There is more to the "Last Man In Theory". It suggests that it is human nature for homeowners to believe the last bit of "expert" advice they receive, even if it is contrary to previous advice. As home inspectors, we unfortunately find ourselves in the position of "First Man In" and consequently it is our advice that is often disbelieved.
Why Didn't We See It Contractors may say "I can't believe you had this house inspected, and they didn't find this problem". There are several reasons for these apparent oversights:
1. Conditions During Inspection It is difficult for homeowners to remember the circumstances in the house, at the time of the inspection. Homeowners seldom remember that it was snowing, there was storage everywhere in the basement or that the furnace could not be turned on because the air conditioning was operating, et cetera. It's impossible for contractors to know what the circumstances were when the inspection was performed. Contractors also rarely understand the standards home inspectors are to follow.
2. The Wisdom Of Hindsight When the problem manifests itself, it is very easy to have 20/20 hindsight. Anybody can say that the basement is wet when there is 2 inches of water on the floor. Predicting the problem is a different story.
3. A Long Look If we spent 1/2 an hour under the kitchen sink or 45 minutes disassembling the furnace, we'd find more problems too. Unfortunately, the inspection would take several days and would cost considerably more.
4. We're Generalists We are generalists; we are not specialists. The heating contractor may indeed have more heating expertise than we do.
5. An Invasive Look Problems often become apparent when carpets or plaster are removed, when fixtures or cabinets are pulled out, and so on. A home inspection is a visual examination. We don't perform any invasive or destructive tests.
6. Taking advantage of a situation Contractors may be desperate or eager for extra work. Is is too tempting for some to attempt to get work approval asap by telling the home owner that someone else will be paying for it.
Not Insurance In conclusion, a home inspection is designed to better your odds. It is not designed to eliminate all risk. For that reason, a home inspection should not be considered an insurance policy. The premium that an insurance company would have to charge for a policy with no deductible, no limit and an indefinite policy period would be considerably more than the fee we charge. It would also not include the value added by the inspection.