Summary
Unofficial version!

Client(s): Jane Client
Property address: Any City, OH 43223
Inspection date: Friday, November 8, 2024

This report published on Saturday, January 4, 2025 9:52:22 AM EST

This is a summary of the inspection performed on the property. It is recommended that the entire report be read.


Exterior and Foundation
7) Safety, Repair/Replace, Evaluate -  The parking area had significant cracks and/or deterioration/trip hazards in areas. A qualified contractor should evaluate and repair or replace driveway sections as necessary.
10) Repair/Replace, Evaluate -  There was deterioration observed around a parking area catch basin/drain. Recommend evaluation and repairs.
11) Repair/Replace, Evaluate -  Sidewalks and/or patios have significant cracks and/or deterioration in areas. Recommend evaluation and repair or replace sidewalk and/or patio sections as necessary.
12) Repair/Replace, Evaluate -  Lintel was rusted and should be protected against rusting and further deterioration. Consider having a contractor evaluate to determine if it should be replaced.
Electric service and Branch Wiring
21) Safety, Repair/Replace, Evaluate -  One section of wiring that was not terminated was found. This is a potential safety hazard due to the risk of shock. A qualified electrician should evaluate and repair as necessary. For example, cutting the wire to length and terminating the wire with wire nuts in a securely anchored, covered, properly sized junction box.
22) Safety, Repair/Replace, Evaluate -  Wire splices were exposed due to not being contained in a covered junction box or in a box that had no cover. This is a safety hazard due to the risk of shock and fire. A qualified electrician should evaluate and make repairs as necessary. For example, install securely mounted junction boxes and/or cover plates where needed to contain wiring splices.
23) Safety, Repair/Replace, Evaluate -  One electric receptacle had reverse-polarity wiring, where the hot and neutral wires are reversed. This is a safety hazard due to the risk of shock. An electrician should evaluate and make repairs as necessary.

conference room
26) Repair/Replace, Evaluate -  Several light fixtures were dim, damaged and/or deteriorated. A qualified electrician should evaluate and repair or replace light fixtures where necessary.

Ballasts appear to be wearing out. Recommend evaluation and/or repair/replacement by qualified licensed electrician.
27) Repair/Replace, Evaluate -  Ark flash panel cover missing.

Recommend evaluation and/or repairs by a qualified licensed electrician.
Heating and cooling
33) Repair/Replace, Evaluate -  Gas appliance exhaust pipe passes though a rubber boot flashing. Gas appliance vents should use a metal boot flashing so as to handle the heat. Recommend evaluation and replacing.
Plumbing, Toilets, Water Heater
47) Repair/Replace, Evaluate -  At least one active leak was found on sump pump and/or waste pipes or fittings. A qualified plumber should evaluate and repair as necessary.
Fireplaces, woodstoves and chimneys
51) Repair/Replace, Evaluate -  The masonry chimney crown was cracked/had gaps and should be evaluated and repaired. The crown is meant to keep water off of the chimney structure. The chimney can be damaged by wet masonry going through freeze-thaw cycles. A properly constructed chimney crown should:
  • Be constructed using either pre-cast concrete slabs, cast-in-place steel reinforced concrete, solid stone, or metal
  • Be sloped down from the flue
  • Overhang the edges by 2 inches
  • Not directly contact the flue liner (if installed), and this gap should be filled with flexible caulk
Lower level
52) Repair/Replace, Evaluate, Monitor -  Evidence of prior water intrusion was found in at least one section of the basement. For example, water stains and/or efflorescence on the foundation or floor, water stains at bases of support posts, etc. Accumulated water is a conducive condition for wood destroying insects and organisms and should not be present in the basement. The client(s) should review any disclosure statements available and ask the property owner(s) about past accumulation of water in the basement. The inspector is unable to determine how much water may enter in the future. The basement should be monitored in the future for accumulated water, especially after heavy and/or prolonged periods of rain. If water is found to accumulate, a qualified contractor who specializes in drainage issues should evaluate and repair as necessary. Typical repairs for preventing water from accumulating in the basement include:
  • Repairing, installing or improving rain run-off systems (gutters, downspouts and extensions or drain lines)
  • Improving perimeter grading
  • Repairing, installing or improving underground footing and/or curtain drains

Ideally, water should not enter the basement, but if water must be controlled after it enters the basement, then typical repairs include installing sump pump(s) or interior perimeter drains.
Attic/Roof
55) Repair/Replace, Evaluate -  Standing water was found on the flat roof. It should evaporate within 48 hours after it rains. If standing water remains after 48 hours, then the roof installation is likely substandard. A qualified roofing contractor should evaluate and repair if necessary to prevent prolonged standing water.
Commercial Life Safety
66) Repair/Replace, Maintain, Evaluate -  Fire alarm and/or burglar alarm systems appear operational, however appeared to be an older system and maybe out of date.
Recommend evaluation and replacement as needed.