Inspector: Leon Jaworowski, P.E.
NYS License No. 16000093216

Property Inspection Report
51 Crest Drive
East Northport, NY 11731

Client(s):  Raymond and Andrea Kuncewitch
Property address:  51 Crest Drive
East Northport, NY 11731
Inspection date:  Monday, February 17, 2020

This report published on Thursday, February 20, 2020 9:25:42 PM EST

Thank you for using ALLIANCE Inspections Inc. for your inspection needs. We appreciate your business and are confident you will be satisfied with the services we provided. Please read through the entire report and review the photographs with any commentary.
If you have any questions regarding the report, or conditions of the residence please feel free to contact us.
The report is confidential and the exclusive property of the Inspector as an instrument of service. It is provided to the Client listed in the report title only for general information on the overall apparent visual condition of the inspected systems and components of the structure identified in the report at the time of the inspection. In addition, the report may have been prepared for client's specific requirements or restrictions, and may also be unreliable to others due to the potential for variable inspection circumstances and the potential for rapidly changing conditions.
Use or duplication of this report by any unauthorized persons without the express written permission of the inspector is strictly prohibited, and may be a violation of copyright laws.

ITEMS ADDITIONALLY EXCLUDED FROM THIS INSPECTION: Sewage disposal systems, below grade drainage systems, site features not identified, irrigation and sprinkler systems, pools, radon testing, security systems, appliances, and thru-wall air conditioners. See Inspection agreement for further limitations and details.

GENERAL NOTES ABOUT THE INSPECTION-The Inspection and this report only apply to the conditions at the time of the Inspection. The information contained in this report may be unreliable for other seasonal or environmental conditions, such as changes in the weather (e.g. rain, snow, temperature, etc.) or groundwater, and may not be applicable beyond the date of the Inspection as conditions sometimes change or become worse within a short period of time. If the Client has any concerns, or any conditions not addressed in this report become apparent, the Client shall notify Alliance Inspections, Inc. and provide an opportunity to re-inspect conditions. If repair or replacement is done without giving Alliance Inspections, Inc. notice and the opportunity to re-inspect conditions Alliance Inspections, Inc. shall have no liability.

Alliance Inspections Inc. are GENERALIST INSPECTORS performing an overall visual inspection and visual assessment of readily accessible systems and components of the building, and can not practically inspect hidden or inaccessible items, or be specialists with expertise in every field related to building construction and maintenance. Alliance Inspections, Inc. can also not inspect, evaluate, or report conditions on concealed systems or components or those that require disassembly or damage to finishes in order to facilitate inspection. Inspections are additionally limited to what can be observed given time restrictions of the inspection as well as cost limitations to the Client, and given it is only a visual inspection of readily accessible systems and components without the use of specialized tools or equipment.

Sometimes specialists in various fields are referred to for maintenance and repairs, or for further evaluations due to the limitations of an Inspection. Occasionally specialists will find additional defects or problems upon further evaluation or dissassembly of components. It is beyond the scope of an Inspection to perform evaluations in specialty fields or dissassemble components or systems, so discovery of additional defects after further evaluation by a specialist is possible, particularly if some time has passed since the Inspection.

In addition specialists sometimes disagree with the general findings and recommendations from an Inspection, and sometimes prefer replacement over repairs due to liability concerns. It is recommended that any such specialist who disagree with opinions or recommendations contained in this report put their findings in writing on company letterhead, signed by a person in responsible charge. Otherwise the Client must decide how much weight to give each opinion.

SEE THE INSPECTION AGREEMENT FOR ADDITIONAL PROVISIONS AND RESTRICTIONS

How to Read this Report
This report is organized by the property's functional areas. Within each functional area, descriptive information is listed first and is shown in bold type. Items of concern follow descriptive information. Concerns are shown and sorted according to these types:
SafetyPoses a safety hazard
Major defectCorrection likely involves a significant expense
Repair/ReplaceRecommend repairing or replacing
Repair/MaintainRecommend repair and/or maintenance
Minor defectCorrection only involves a minor expense
MaintainRecommend ongoing maintenance
EvaluateRecommend evaluation by a specialist
MonitorRecommend monitoring in the future
ServiceableItem or component is in serviceable condition
CommentFor your information

Click here for a glossary of building construction terms.Contact your inspector If there are terms that you do not understand, or visit the glossary of construction terms at https://www.reporthost.com/glossary.asp

Table of Contents

General Information
Grounds
Exterior
Foundation
Basement
Roof / Attic
Electric
Plumbing / Fuel Systems
Water Heater
Heating
Kitchen
Bathrooms / Laundry / Sinks
Interior Rooms / Areas
Structural Pest Findings

General InformationTable of contents
Report number: 2020-002
Time started: 3:35
Time finished: 7:30
Inspector: Leon Jaworowski, PE, LEED, AP
Present during inspection: Client, Realtor
Client present for discussion at end of inspection: Yes
Weather conditions: Clear
Temperature: Cool
Ground condition: Dry
Type of building: Single family, Residential Building
Number of residential units inspected: 1
Age of building(s): 99 Yrs.
Source for building age: Property listing
Front of building faces: East
Main entrance faces: East
Occupied: No, Furniture or stored items were present
1) - We appreciate the opportunity to conduct this inspection for you! Please carefully read your entire Inspection Report. Call us 631-241-4038 after you have reviewed your report, so we can go over any questions you may have. Remember, when the inspection is completed and the report is delivered, we are still available to you for any questions you may have, throughout the entire closing process.

Properties being inspected do not "Pass" or "Fail. The following report is based on an inspection of the visible portion of the structure; inspection may be limited by vegetation and possessions. Depending upon the age of the property, some items like GFCI outlets may not be installed; this report will focus on safety and function, not current code. This report identifies specific non-code, non-cosmetic concerns that the inspector feels may need further investigation or repair.

For your safety and liability purposes, we recommend that licensed contractors evaluate and repair any critical concerns and defects. Note that this report is a snapshot in time. We recommend that you carry out a final walk-through inspection immediately before closing to check the condition of the property, using this report as a guide. We offer a Final Walk Through Inspection as one of our services. We provide this service at a discounted rate to former clients.

Please note the link for this report expires within 120 days so please print a copy of this report for your records as soon as possible.
2) - Based on construction observed, additions and/or modifications to this property may have been made without the owner having attained permits or inspections from the municipality. Work may have been performed by someone other than a qualified contractor or person. The client should consult with the property owner about this, and if necessary research permits.

At worst case, if substantial work was performed without permits, this knowledge must be disclosed when the building is sold in the future. This can adversely affect future sales. Also, the local municipality could require costly alterations to bring the building into legal compliance or even require that the additions or modifications be removed.
Limitations: The following items are not included in this inspection: swimming pools, spas, hot tubs, water features and related equipment; playground, recreation or leisure equipment; landscape lighting; areas below exterior structures with less than three feet of vertical clearance; irrigation systems; invisible fencing; sea walls, docks and boathouses. Any comments made regarding these items are as a courtesy only. Note that the inspector does not test or determine the adequacy of drainage systems for grounds, walkways, below-grade stairs and roof downspouts. The inspector does not provide an evaluation of geological conditions and/or site stability, compliance of pool or spa fencing with municipal requirements, or determination that deck, balcony and/or stair membranes are watertight.
The following items are excluded from this inspection: Shed
Condition of fences and gates: Appeared serviceable
Fence and gate material: Wood, Plastic
Site profile: Minor slope
Condition of driveway: Appeared serviceable
Driveway material: Asphalt
Condition of sidewalks and/or patios: Appeared serviceable
Sidewalk material: Asphalt
Condition of decks, porches and/or balconies: Appeared serviceable
Condition of guardrails: Appeared serviceable
Deck, porch and/or balcony material: Wood
3) Repair/Replace, Minor defect - Flashing was missing from above one or more deck ledger boards. This can cause moisture to accumulate between the ledger board(s) and the building. Rot may result in this area and cause the ledger board fasteners to fail. The deck may separate from the building in this event and poses a significant safety hazard. A qualified contractor should install flashing above ledger board(s) where necessary. For more information on installing deck ledger boards visit:
http://www.hometime.com/Howto/projects/decks/deck_4.htm

And for more information on building safe decks in general, visit: http://www.thisoldhouse.com/toh/knowhow/exteriors/article/0,16417,212625,00.html
4) Comment - Decking boards were spaced closer together than 3/8 inch with accumulated organic debris (leaves, fir needles, etc.). This is a conducive condition for wood destroying insects and organisms. Debris should be cleaned as necessary to prevent accumulation and resultant rot. If or when the deck boards are replaced, recommend spacing boards so they're at least 3/8 inch apart to allow debris to fall through the cracks rather than accumulate in them.
5) - Grading and drainage are probably the most significant aspects of a property, simply because of the direct and indirect damage that moisture can have on structures. More damage has probably resulted from moisture and expansive soils than from most natural disasters. Also, there should be gutters and downspouts with splash blocks that discharge away from the building. We have discovered evidence of moisture intrusion inside structures when it was raining that would not have been apparent otherwise.

In addition, we recommend that downspouts do not terminate over paved areas such as walks or driveways, as they can contribute to icy slip and fall hazards in winter.

Minor settlement or hairline cracks in drives, walks or even foundations are normal to properties of any age. They should, however, be monitored for expansion and sealed as necessary.

Vegetation too close to the home can contribute to damage through root damage to the foundation, branches abrading the roof and siding, and leaves providing a pathway for moisture and insects into the home.

Although rails are not required around drop-offs less than 30 inches, consider your own personal needs and those of your family and guests. By today's standards, spindles at decks and steps should be spaced no more than 4 inches apart for the safety of children.

An egress ladder and window should also be installed within the well or basement wall, especially where below-grade bedrooms exist and no basement access door exists.
Limitations: The following items are not included in this inspection: below-grade foundation walls and footings, or those obscured by vegetation or building components; exterior building surfaces or components obscured by vegetation, stored items or debris. Any comments made regarding these items are as a courtesy only. Some amount of cracking is normal in concrete slabs and foundation walls due to shrinkage and drying. Note that the inspector does not determination the adequacy of sump pumps, seismic reinforcement, nor determine if support posts, columns, beams, joists, studs, trusses, etc. are of adequate size, spanning or spacing.
Window/Door Frames and Trim Conditions: Area where vinyl j channel meets frame of window needs caulkin
SOFFIT (Underhang section right below roof, sticks out from top of wall): Vinyl soffit (underhang) with venting holes for attic ventilation.
FASCIA (Board right below roof edge): Wooden fascia (boards behind gutters and at top of side walls) covered with metal
Window wells are made of: Brick
Window Well Conditions: Debris and/or vegetation in or around window well. Recommend cleaning as needed., Poor or no gravel base. Recommend several inches of gravel in window well for water to flow through and prevent erosion.
Condition of exterior stairs: Appeared serviceable
Condition of handrails: Appeared serviceable
Exterior stair material: Wood
Condition of gutters, downspouts and extensions: Appeared serviceable
Gutter and downspout material: Metal
Gutter and downspout installation: Full
Condition of chimneys: Required repair, replacement and/or evaluation (see comments below)
Chimney type: Metal, with wood enclosure
6) Repair/Replace, Evaluate, Monitor - The metal chimney pipe extension is showing signs of rust and deterioration. The connection at the limits of the wood enclosure appear to be substandard and deteriorated.
Photo
Photo 6-1 
7) Repair/Replace, Evaluate - Some downspouts were loose. Water may accumulate around the building foundation as a result. A qualified person should evaluate and repair as necessary.
Photo
Photo 7-1 
8) Repair/Maintain, Minor defect - There is deterioration of the vinyl siding in the back of the home. It appears to be wrinkling of the vinyl surface most likely caused from excessive heat exposure to the area.
Photo
Photo 8-1 
9) Repair/Maintain, Evaluate - There is a brink window well below the dinning room bay window that needs to be cleaned. Also in this same area, the bottom of the window projection needs to be insulated and sealed to prevent entrance of vermin into the wall cavity. Additionally, the foundation supporting the bay window projection is substandard.
Photo
Photo 9-1 
10) Repair/Maintain, Evaluate - The electrical GFCI receptacle outdoor box was not securely attached to the deck stair. It should be repaired by a licensed electrician.
Photo
Photo 10-1 
11) Repair/Maintain - Soil was in contact with or less than six inches from siding and/or trim. This is a conducive condition for wood destroying insects and organisms. Soil should be graded and/or removed as necessary so there are at least six inches of space between the siding and trim and the soil below.
Photo
Photo 11-1 This section of siding in the front is appears less than 6 inches above the soil line. The garden soil should be regraded to provide more than 6 inches of space below the siding.
12) - There is staining of the vinyl siding caused by a mold type growth. The siding should be cleaned of this material.
Photo
Photo 12-1 
Limitations: The following items are not included in this inspection: below-grade foundation walls and footings, or those obscured by vegetation or building components; exterior building surfaces or components obscured by vegetation, stored items or debris. Any comments made regarding these items are as a courtesy only. Some amount of cracking is normal in concrete slabs and foundation walls due to shrinkage and drying. Note that the inspector does not determination the adequacy of sump pumps, seismic reinforcement, nor determine if support posts, columns, beams, joists, studs, trusses, etc. are of adequate size, spanning or spacing.
Condition of foundation and footings: Appeared serviceable
Foundation type: Basement (See Basement Section), Crawlspace
Foundation material: Concrete block
Footing material: Not determined
Anchor bolts for seismic reinforcement: Not determined
Condition of floor substructure: Required repairs, replacement and/or evaluation (see comments below)
Main Beam material: Solid wood
Main Beam Column Supports: Temporary metal column(s) being used, appears no footing is in place
Floor structure: Solid wood joists
Insulation: None Visible
Condition of concrete slab floor(s): Required repairs, replacement and/or evaluation (see comments below), There appears to be hollow spots that were noted in the basement floor.
Condition of crawl space: Appeared serviceable
Crawl space inspection method: Partially traversed
Insulation material underneath floor above: None visible
Ventilation: None visible
Vapor barrier present: No
13) Major defect, Repair/Replace - No insulation was installed under the floor in the crawl space. A qualified contractor should install insulation for better energy efficiency and as per standard building practices with an R rating recommended for this area. For more information, visit:
http://www.eere.energy.gov/consumer/tips/insulation.html
14) Repair/Replace, Evaluate, Monitor - Substandard construction was found in some areas of the floor substructure. For example, over spanned beams. A qualified contractor should evaluate and repair as necessary, and as per standard building practices.

The main beam is missing column supports at critical locations adjacent to the basement stairs. Existing temporary metal and wood columns should be replaced with steel columns with adequate footings below the basement floor. The concrete basement floor was also noted to contain hollow spots.
Photo
Photo 14-1 The stress on the main beam, supported by the temporary columns, is caused by the floor rafters not spanning across where the basement stairs come down to the floor (shown by the arrow with two heads). The temporary beams should be replaced with adequately sized columns with footings, at appropriately spaced intervals. The work should be completed by a qualified contractor.
Photo
Photo 14-2 The temporary wood and metal colums supporting the main beam should be replaced with adequately spaced colums with footings.
Photo
Photo 14-3 This column is supporting a few floor joists. This column appears to have been permanently anchored into the basement concrete floor.
15) Repair/Replace, Evaluate, Comment - There is an abandoned fuel oil tank in a crawl space located in the northwest corner of the home below the kitchen and 1st floor bathroom. The tank is partially buried and shows signs of rusting. The tank should be removed from the crawl space.
Photo
Photo 15-1 There is an abandoned fuel oil tank located in the crawl space.
Photo
Photo 15-2 Approximately 12 inches of the bottom of the tank is berried below grade. There is rusting of the tank below the soil line as shown by the arrows. The tank should be removed from the crawl space by a qualified specialist contractor.
16) Repair/Replace, Evaluate - The vapor barrier in the crawl space was missing in all areas. This is a conducive condition for wood destroying insects and organisms due to the likelihood of water evaporating into the structure from the soil. A qualified person should evaluate and replace or repair sections as necessary. Standard building practices require the following:
  • The soil below the vapor barrier should be smooth and free from sharp objects.
  • Seams should overlap a minimum of 12 inches.
  • The vapor barrier should lap up onto the foundation side walls.

  • Better building practices require that:
  • Seams and protrusions should be sealed with a pressure sensitive tape.
  • The vapor barrier should be caulked and attached tightly to the foundation side walls. For example, with furring strips and masonry nails.
17) Repair/Replace, Evaluate - Ventilation for the crawl space was substandard. This may result in high levels of moisture in the crawl space and can be a conducive condition for wood destroying insects and organisms. Standard building practices require one square foot of vent area for 150 to 200 square feet of crawl space. Vents should be evenly distributed and within a few feet of corners to promote air circulation. A qualified contractor should evaluate and install vents as per standard building practices.
18) Repair/Replace, Evaluate - Subfloor foundation support located along a portion of the crawl space perimeter was missing. This condition should be corrected by a qualified contractor.
Photo
Photo 18-1 A portion of the crawlspace foundation wall is missing and the supporting beam is missing adequate support between the length shown by the arrows. A new properly spaced support beam should be placed by a qualified contractor.
19) Repair/Replace, Monitor - Spauling has occurred which is a cracking/peeling of the surface area of the interior/exterior of the concrete foundation. Suggest scraping off all loose material and apply sealant. You may want to hire a qualified professional to perform this work.
Photo
Photo 19-1 
20) Repair/Maintain, Evaluate, Monitor - One or more minor exterior cracks (1/8 inch or less) were found in the foundation. These don't appear to be a structural concern, but recommend sealing them to prevent water infiltration and monitoring them in the future. Numerous products exist to seal such cracks including hydraulic cement, resilient caulks and epoxy sealants.
Photo
Photo 20-1 
Photo
Photo 20-2 
Photo
Photo 20-3 
Photo
Photo 20-4 
21) - Foundation
A foundation provides a stable, rigid base to support a home. The foundation supports the frame and structure and protects it from moisture and contact with the soil. The foundation must rest on firm soil and be protected from water entry or excessive dampness. The majority of homes are built on foundations that form a crawl space or full basement. The basement rests on a footing that supports the home's weight. Foundation walls are constructed of brick, concrete block, poured concrete, clay tile, stone, or similar materials. The basement floor usually consists of poured concrete. Crawl spaces can either have a dirt or concrete floor.

Full-depth basements are the most complicated type of foundation because of potential water problems and the pressure of soil outside the basement walls. While full-depth basements require the most maintenance, crawl spaces and slab foundations must also be protected from excessive moisture.

Proper grading around the house is your best protection against seepage into the basement that may cause expensive damage. When a home is built, workers dig the excavation several feet larger than the basement walls to allow for construction clearances. At the base of the hole, near the footing, they install a drain tile system and cover it with a small amount of gravel. They also apply a damp-proof coating to the walls and the hole is filled. Most of the hole around the basement is filled with soil from the site. This may contain gravel, rock, wood, paper, and unfortunately almost anything no longer useful to home construction. For the next 20 years, this soil and "stuff" settles around your basement walls. It settles quickly for the first few years and more slowly after that.

To divert surface water the soil should pitch away from the home with a 1 inch pitch per foot for about 6 feet beyond the foundation. All downspouts from the roof drainage system should be at least 3 feet away from the foundation. Open window wells should have either grates or, preferably, a weatherproof shield over them. This will keep the rain and snow from building up inside the well and possibly leaking into the home.
Condition of the basement: Appeared serviceable
Type: Finished Basement (framed walls with wall coverings)
Miscellaneous Items 1:: Wood Framing with no insulation
Miscellaneous Items 2: No heat in basement, If main heating source (boiler or furnace) is in basement the unit will give off some heat
Floor Material: Plain Concrete
Ceiling type or covering: First floor wood beams and first floor sheathing
Condition of ceilings: Appeared serviceable
Wall type or covering: Masonry
Condition of walls: Appeared serviceable
Type: Wood Windows, Hopper Windows, Slider Windows
Condition: Windows appear to be original single pane units, budget for replacement - See Pictures
22) Safety, Repair/Replace, Evaluate - One or more junction boxes they are installed did not have covers. This is a safety hazard due to the risk of shock and fire. A qualified electrician should evaluate and repair as necessary.
Photo
Photo 22-1 This junction box is located in the basement.
23) Safety, Repair/Replace, Evaluate - One or more electric receptacles at the basement had no visible ground fault circuit interrupter (GFCI) protection. This is a safety hazard due to the risk of shock. Recommend having a qualified electrician evaluate to determine if GFCI protection exists, and if not, repair as necessary. For more information, visit:
http://www.mikeholt.com/documents/nec/pdf/GFCI_requirement_page2.pdf
24) Evaluate, Monitor, Comment - It was noted that the basement floor may contain hollow areas, as a step in the middle of the basement floor was observed. The floor area should be evaluated and monitored for the location of additional hollow spots.
25) Comment - Some basement sections were not evaluated due to lack of access from the following conditions: stored items and couldn't be fully evaluated.
Photo
Photo 25-1 
Photo
Photo 25-2 
Roof / AtticTable of contents
Limitations: The following items or areas are not included in this inspection: areas that could not be traversed or viewed clearly due to lack of access; areas and components obscured by insulation; solar roofing components; any comments made regarding these items are as a courtesy only. Note that the inspector does not determination if rafters, trusses, joists, beams, etc. are of adequate size, spanning or spacing. The inspector does not provide an estimate of remaining roof surface life, does not determine that the roof has absolutely no leaks at the time of the inspection, and does not determine that the roof won't leak in the future. Only active leaks and evidence of past leaks observed during the inspection are reported on as part of this inspection. To absolutely determine than no leaks exist, complete access to all roof structure areas must be available during a wide variety of weather conditions, including prolonged heavy rain, high wind from varying directions, heavy accumulations of snow and/or ice, and melting snow and ice.
Condition of roof structure: Appeared serviceable
Roof type: Gable, Hipped
Roof inspection method: Viewed from ground with binoculars, Viewed from windows
Condition of shingle and/or shake roof surface materials: Appeared serviceable
Roof surface material: Asphalt or fiberglass composition shingles (15 year life)
Apparent number of layers of roof surface material: One layer of Roofing was observed
Condition of exposed flashings: Required repair, replacement and/or evaluation (see comments below)
Condition of attic: The attic was not inspected. See below.
Attic inspection method: Not inspected, Substandard attic access existed from a 2nd floor bedroom closet.
Attic ventilation: Fan cover was noticed on outside roof area.
26) Repair/Replace - Some "rubber boot" flashings were loose. Leaks may occur as a result. A qualified contractor should evaluate and repair/replace flashings where necessary.
Photo
Photo 26-1 
27) Monitor, Serviceable, Comment - Skylight flashing appears servicable
28) Comment - The attic ventilation fan was not tested and is excluded from this inspection.
29) - Roofing
All roofs have structural framing of joists or trusses that support a wood deck that is either plywood, solid 3/4 inch wood planking or oriented strand board. In general, the two basic styles are sloped and low-sloped (or flat) roofs.
Asphalt fiberglass shingles (3-tab or architectural) are the most common type of sloped roofing material. A typical asphalt shingle can last from 15-40 years. Asphalt fiberglass shingles come in many shapes and sizes. Other materials used for sloped roofs include wood shakes, wood shingles, cement asbestos, tile, slate, metal, and cement tile.

Low-slope or flat roofs require a special roofing material to seal against moisture. Since the slope is low, water does not easily run from the surface. Materials used include single-ply rubber, roll roofing, torch down (modified bitumen), metal, and built-up roofing. On occasion it may be acceptable to use a sloped shingle on a flat roof if an ice membrane is used. A flat roof should have a slight slope to prevent puddling of water. Flat roof material is not made to walk on.

Roof Ventilation
Ventilation is necessary to remove moisture from the attic. This is achieved through a various combinations of roof vents, soffit vents, gable wall vents, ridge vents, static vents, and ventilation fans. Good attic ventilation lowers air conditioning costs. Bathroom and kitchen exhaust fans are needed to remove excessive moisture, but they must be routed to the exterior and not into the attic. Excessive moisture causes mildew and mold.

Gutters and Downspouts
When it rains, your roof sheds a tremendous quantity of water that must be moved away from the foundation to protect the basement or crawlspace. Always have downspouts drain at least 3 feet away from the foundation. Always make sure your gutters are cleaned and flowing correctly. If downspouts are draining underground always monitor during heavy rain to make sure there is no back up of water.

Adequate attic ventilation, solar / wind exposure, and organic debris all affect the life expectancy of a roof (see www.gaf.com for roof info).  Always ask the seller about the age and history of the roof.  Metal roofs in snow areas often do not have gutters and downspouts, as there is a concern that snow or ice cascading off the roof may tear gutters from the house.  Likewise, be advised that such cascading may cause personal injury or even death.  If this house has a metal roof, consult with qualified roofers or contractors regarding the advisability of installing a damming feature which may limit the size and amount of snow / ice sliding from the roof.  
30) - Most newer homes are insulated with fiberglass, cellulose fiber, rigid plastic foam, or a combination of these products. Older homes may have vermiculite, wood shavings, paper products, and other types of insulation.

Often, homeowners add insulation to walls and attics of older homes to increase energy efficiency. Insulation is rated with an R-value, which simply indicates the resistance to heat flow. The higher the R-value, the higher the resistance. The key thing to remember is that when you double the R-value you cut the heat loss in half.

Most fiberglass is rated at about R-3 per inch of thickness. A 6 inch section of fiberglass would be rated about R-19. The R-value for rigid foam ranges from 5 to 7 per inch. Cellulose and mineral wool provide about an R-3 per inch. Most walls built today have an R-value around 11-13 and attics have an R-value around 30.

No matter how well a home is constructed, moisture will reach the attic. It is impossible to seal this area. So ventilation is necessary to remove moisture and excessive heat from the attic. This is achieved through various combinations of roof vents, soffit vents, gable end vents, ridge vents, and ventilation fans.
Limitations: The following items are not included in this inspection: generator systems, surge suppressors, inaccessible or concealed wiring; underground utilities and systems; low voltage lighting or lighting on timers or sensors. Any comments made regarding these items are as a courtesy only. Note that the inspector does not determine the adequacy of grounding or bonding, does not determine if this system has an adequate capacity for the client's specific needs, nor determine if this system has any reserve capacity for additions or expansion. The inspector does not operate circuit breakers as part of the inspection, install or change light bulbs, nor determine the operability of every wall switch.
Electric service condition: Appeared serviceable
Primary service type: Overhead
Number of service conductors: 2
Service voltage (volts): 120
Service amperage (amps): Not determined, No main braker was evident in panel.
Primary service overload protection type: Circuit breakers
Service entrance conductor material: Aluminum
Main disconnect rating (amps): No main disconnect existed.
System ground: Cold water supply pipes
Condition of main service panel: Required repair, replacement and/or evaluation (see comments below)
Location of main service panel #A: Basement
Location of main disconnect: No main disconnect was observed.
Branch circuit wiring type: Non-metallic sheathed
Condition of branch circuit wiring: Serviceable
Condition of smoke detectors: Appeared serviceable
Smoke detectors present: Yes
Carbon monoxide detectors present: Yes
Smoke detector power source: Battery
31) Safety, Repair/Replace, Evaluate - The electric service was configured so that too many hand movements are necessary to turn off all power for the service. Standard building practices require there to be six or fewer switches and six or fewer hand movements necessary to turn off all power for an electric service. This may be a safety hazard during an emergency when the power needs to be turned off quickly. A qualified electrician should evaluate and make repairs as necessary.
32) Safety, Repair/Replace, Evaluate - Modifications were made to panel #A or to equipment inside. Electric panels and equipment are Underwriter Laboratory rated devices, and modifications to them are not allowed. A qualified electrician should evaluate and replace or repair as necessary.
Photo
Photo 32-1 
33) Safety, Repair/Replace, Evaluate - Extension cords were being used as permanent wiring in one or more areas. They should only be used for portable equipment on a temporary basis. Using extension cords as permanent wiring poses a fire and shock hazard, and is an indication that wiring is inadequate and should be updated. Extension cords may be undersized. Connections may not be secure, resulting in power fluctuations, damage to equipment, and sparks that could start a fire. Extension cords should be removed as necessary, or a qualified electrician should evaluate and make repairs as necessary. For example, install additional circuits and/or electric receptacles. This condition existed in the crawlspace located under the kitchen/1st floor bathroom and in the backyard shed.
Photo
Photo 33-1 
Photo
Photo 33-2 The shed contained an extension cord that is being used as wiring.
34) Safety, Minor defect - Some cover plates on junction and/or receptacle boxes were missing. They are intended to contain fire and prevent electric shock from exposed wires. This is a safety hazard due to the risk of fire and shock. A qualified person should repair as necessary.
Photo
Photo 34-1 This uncovered receptacle is installed in the crawlspace. The receptacle should be GFCI and be contained in an outdoor enclosure.
Photo
Photo 34-2 This junction box is located in the basement.
35) Safety, Maintain - Batteries in all the smoke alarms should be replaced after taking occupancy, and annually in the future. "Chirping" noises emitted from smoke alarms typically indicate that batteries need replacing. For more information, visit http://www.cpsc.gov/cpscpub/pubs/5077.html
36) Safety, Evaluate - Branch circuit wiring installed in buildings built prior to the mid 1980s is typically rated for a maximum temperature of only 60 degrees Centigrade. This includes non-metallic sheathed (Romex) wiring, and both BX and AC metal clad flexible wiring. Knob and tube wiring, typically installed in homes built prior to 1950 may be rated for even lower maximum temperatures. Newer electric fixtures including lighting and fans typically require wiring rated for 90 degrees Centigrade. Connecting older, 60 degree-rated wiring to such newer fixtures is a potential safety hazard due to the risk of fire. Repairs for such conditions often involve replacing the last few feet of wiring to newer fixtures with new 90 degree-rated wire. This often requires installing a junction box to join the old and new wiring.

It is beyond the scope of this inspection to determine if such incompatible components are installed, or to determine the extent to which they're installed. Based on the age of this building, the client should be aware that this safety hazard may be present in this building. Recommend consulting with the property owner to determine if and when newer fixtures were installed, and/or to have a qualified electrician evaluate and repair as per standard building practices.
37) Major defect, Repair/Replace, Evaluate - The electric service to this property appeared to be rated at less than 200 amps, and may be inadequate for the client's needs. Recommend consulting with a qualified electrician about upgrading to a 200 amp service.
Photo
Photo 37-1 
38) Repair/Replace, Evaluate - One or more GFCI electric receptacles appeared to have no power on the backyard deck. Recommend asking the property owner about this. Switches may need to be operated to make some receptacles energized. If necessary, a qualified electrician should evaluate and make repairs as necessary.
Photo
Photo 38-1 This outside GFCI breaker and the other one on the other side of the sliding glass doors did not have power.
39) Comment - All smoke detectors were not tested due to the following conditions: out of reach.
40) - The electrical supply to your home begins outside, either from your electric company's overhead or underground line. The main electric panel, which is usually located in the basement or garage, is divided into circuits through individual breakers or fuses and is fed through the wiring system, outlets and cords to various electrical devices.
Any home that has a Bulldog Pushmatic, Zinsco, Sylvania Zinsco or Federal Pacific main electric panel should have it evaluated by a licensed electrician, as these are older types of panels and breakers that have been known to overheat and cause house fires.
Most modern homes have 220-volt systems with a minimum of 100 amps of power. Older houses may have fuses and can have 60 amp systems. Main panels can have sub-panels that are fed by the main panel. These sub-panels can range in size from 30 amps on up. On most main panels you will find one breaker marked "main." This breaker will be near the top of the box and will be 100, 150, or 200 amp. If you switch this breaker off, all power in your home will be disconnected.
Distribution wiring is what routes electrical power to lights, outlets and appliances. Most of this wiring is buried in walls and attics, but some will be visible near the main service panel and in basements and crawl spaces. Since the 1970's, plastic shielded wiring (Romex is a common brand name) has been used in residential construction. Older homes may have cloth shielded wiring, BX or flexible metal-shielded wiring, or even conduit (metal pipe). The composition of the wire used is normally copper but during the 1950's a tin coating was used for a short period of time to cover the copper and in the 1970's solid 1 strand aluminum was briefly used. Any type of single strand aluminum wiring has been proven to be a fire hazard and if found will be noted on our report and should be evaluated by a licensed electrician.
A ground fault circuit interrupter GFCI is a valuable safety device that should be installed in bathrooms, kitchens, sink locations, unfinished basements, laundry rooms, garages and exterior outlets. GFCI outlets or circuits provide a high level of safety against shock. A tiny imbalance in the power and neutral lines will trip a GFCI meaning that the electric is instantly shut off. The imbalance indicates potential current leakage that could deliver a shock.
Some baths may have non-GFCI outlets which are protected by a GFCI outlet in a remote area (garage, another bath, etc.). 
Electricity requires at least 2 wires: it pushes through the live or positive wire (usually black in color) and returns through the neutral wire (usually white in color). This is why all electrical devices have plugs with at least two prongs. Modern systems add a third (ground) wire for safety.
Also, note that most electricians agree that smoke detectors are good for about 5 years, and the breakers in your panel box have an expected life of about 20 years.  Therefore, if this home was built before 1991, consider having the panel box and breakers evaluated by a licensed electrician, as an overheated breaker can result in a structural fire.  
If your home does not have a carbon monoxide detector, it is now required to have them in New York State, we recommend making that investment.
Plumbing / Fuel SystemsTable of contents
Limitations: The following items are not included in this inspection: private wells and sewage disposal systems; main, side and lateral sewer lines; gray water systems; pressure boosting systems; incinerating or composting toilets; fire suppression sprinkler systems; water softeners, conditioners or filtering systems; plumbing components concealed within the foundation or building structure, or in inaccessible areas such as below tubs; underground utilities and systems; overflow drains for tubs and sinks; backflow prevention devices. Any comments made regarding these items are as a courtesy only. Note that the inspector does not operate water supply or shut-off valves due to the possibility of valves leaking or breaking when operated. The inspector does not test for lead in the water supply, the water pipes or solder, does not determine if plumbing and fuel lines are adequately sized, and does not determining the existence or condition of underground or above-ground fuel tanks.
Condition of service and main line: Appeared serviceable
Location of main water meter: In basement
Location of main water shut: In basement
Water service:
Service pipe material: Copper
Condition of supply lines: Appeared serviceable
Supply pipe material: Copper
Condition of waste lines: Appeared serviceable
Waste pipe material: Plastic, Cast iron
Condition of fuel system: Appeared serviceable
Location of main fuel shut: Outside
Visible fuel storage systems: An abandoned fuel oil tank exists in the crawl space (see Foundation Section)
41) Safety, Repair/Replace, Evaluate - The gas meter was located where it is subject to damage from vehicles. This is a safety hazard. A qualified contractor should install barriers as per standard building practices.
Photo
Photo 41-1 
42) Safety, Repair/Replace, Evaluate - The gas meter was located too close to other objects and has substandard workspace. Standard building practices require that a minimum clear area of 3 feet exist around the meter, except for behind it. A qualified person and/or the gas utility company should evaluate and repair as necessary, and as per standard building practices.
43) Safety, Repair/Replace, Evaluate - One or more sections of gas supply pipes were loose or had substandard support. Standard building practices require that gas supply piping be supported by clamps as follows:
  • Every six feet for two inch pipe
  • Every eight feet for 3/4 inch pipe
  • Every 10 feet for 1 1/4 inch pipe

A qualified contractor should evaluate and repair as necessary, and as per standard building practices.
Photo
Photo 43-1 
44) Safety, Comment - Copper water supply pipes in buildings built prior to 1986 may be joined with solder that contains lead. Lead is a known health hazard, especially for children. Laws were passed in 1985 prohibiting the use of lead in solder, but prior to that solder normally contained about 50 percent lead. The client should be aware of this, especially if children will be living in this structure. Evaluating for the presence of lead in this structure is not included in this inspection. The client should consider having a qualified lab test for lead, and if necessary take steps to reduce or remove lead from the water supply. Various solutions such as these may be advised:
  • Flush water taps or faucets. Do not drink water that has been sitting in the plumbing lines for more than six hours.
  • Install appropriate filters at points of use.
  • Use only cold water for cooking and drinking. Hot water dissolves lead more quickly than cold water.
  • Use bottled or distilled water.
  • Treat well water to make it less corrosive.
  • Have a qualified plumbing contractor replace supply pipes and/or plumbing components as necessary.

For more information visit:
http://www.cpsc.gov/CPSCPUB/PUBS/5056.html
http://www.epa.gov/safewater/lead/index.html
45) Repair/Replace - One or more outside faucets were not the "frost-free" design, and are more likely to freeze during cold weather. Recommend having a qualified plumber upgrade these with frost-free faucets to prevent freezing and pipes bursting.
46) - Plumbing is an important concern in any structure. Moisture in the air and leaks can cause mildew, wallpaper and paint to peel, and other problems. We have tried to identify as many issues as possible but some problems may be undetectable due to problems within the walls or under the flooring.

Note that in some locations, sewer service and/or water service might be provided by private waste disposal system (cesspool). Inspection, testing, analysis, or opinion of condition and function of private waste disposal systems and wells is not within the scope of a home inspection. Recommend consulting with seller concerning private systems and inspection, if present, by appropriate licensed professional familiar with such private systems. If a Septic System is on the property, pumping is generally recommended prior to purchase, and then every three years.
Water HeaterTable of contents
Limitations: The following items are not included in this inspection: solar water heating systems; circulation systems. Any comments made regarding these items are as a courtesy only. Note that the inspector does not provide an estimate of remaining life on water heaters, does not determine if water heaters are appropriately sized, or perform any evaluations that require a pilot light to be lit.
Type: Tank
Energy source: Natural gas
Capacity (in gallons): 40
Manufacturer: General Electric
Model: PG40So9AVF00
Location of water heater: Basement
Condition of burners: Appeared serviceable
Condition of venting system: Appeared serviceable
Condition of combustion air supply: Appeared serviceable
47) Evaluate, Monitor, Comment - The estimated useful life for most water heaters is 8 to 12 years. The inspector was unable to determine the age of the water heater. The client should be aware that this water heater may be near, at, or beyond its useful life and may need replacing at any time. Recommend attempting to determine the water heater's age, and budgeting for a replacement if necessary.
48) - A water heating system for drinking and bathing water can come in many shapes and sizes. The most conventional type of water heating system is the stand alone type that includes its own tank and heating system. This type of system can use either oil, natural gas, propane or electric to heat water.

Another type of water heating system found is a tankless system where the water is heated through the heating system, in most cases this heating system is a hot water or hydronic heating system. One drawback to this type of system is that if the home needs a large amount of hot water at a specific time this system may not be able to keep up with the demand.

There are also other combination systems available, for example; there is a system available where the water is heated through the heating system but stored in a separate tank.
Limitations: The following items are not included in this inspection: humidifiers, dehumidifiers, electronic air filters; solar, coal or wood fired heat systems; thermostat or temperature control accuracy and timed functions; heating components concealed within the building structure or in inaccessible areas; underground utilities and systems; safety devices and controls (due to automatic operation). Any comments made regarding these items are as a courtesy only. Note that the inspector does not provide an estimate of remaining life on heating system components, does not determine if heating systems are appropriately sized, or perform any evaluations that require a pilot light to be lit. It is beyond the scope of this inspection to determine if furnace heat exchangers are intact and free of leaks.
Condition of heating system: Appeared serviceable
Location of heating system: Basement
Heating type: Baseboard, Steam
Fuel type: Natural gas
Approximate BTUs: 90,000
Manufacturer: HB Smith Company
Model: G20-S-4Con (SerialH79-2043)
Condition of burners: Appeared serviceable
Condition of venting system: Appeared serviceable
Condition of combustion air supply: Appeared serviceable
Condition of distribution system: Appeared serviceable
Distribution system: Pipes and convectors, Pipes and radiators
Condition of controls: Appeared serviceable
49) Repair/Replace, Evaluate - The following conditions were noted with the steam boiler: excessive variation in water level. A qualified contractor should evaluate and repair as necessary.
50) Repair/Replace - All distribution pipes in the basement were uninsulated. A qualified person should install insulation in unconditioned spaces as per standard building practices for better energy efficiency.
51) Repair/Maintain, Evaluate - The last service date of this system appeared to be more than one year ago, or the inspector was unable to determine the last service date. The client should ask the property owner when it was last serviced. If unable to determine the last service date, or if this system was serviced more than one year ago, a qualified contractor should service this system and make repairs if necessary. This servicing should be performed annually in the future.
52) Evaluate, Comment - No Data on last service date
53) Evaluate, Comment - This heating system used hydronic and/or steam heat. It is a specialty system, and only a limited evaluation was performed during the inspection. Recommend a full evaluation by a qualified specialist.
54) - The heating, ventilation, and air conditioning/cooling system (often referred to as HVAC) is the climate control system for the structure. The goal of these systems is to keep the occupants at a comfortable level while maintaining indoor air quality, ventilation while keeping maintenance costs at a minimum. The HVAC system is usually powered by electricity and/or natural gas, but can also be powered by other sources such as butane, oil, propane, solar panels, or wood.

Most homes are heated with either a warm air furnace that uses ducts and ceiling/wall registers or a hydronic (warm water) system that uses radiators, baseboard (convector) elements, or heating pipes buried in walls or floors.
Limitations: The following items are not included in this inspection: free-standing or portable appliances such as dishwashers, trash compactors, refrigerators, freezers, ice makers; specialty appliances such as hot water dispensers, water filters and trash compactors; appliance timers, clocks, cook functions, self and/or continuous cleaning operations, thermostat or temperature control accuracy, and lights. Any comments made regarding these items are as a courtesy only. Note that the inspector does not provide an estimate of the remaining life of appliances, and does not determine the adequacy of operation of appliances such as dishwashers, garbage disposals, trash compactors, ovens, broilers, etc.
Condition of counters: Appeared serviceable
Condition of cabinets: Appeared serviceable
Condition of sinks and related plumbing: Appeared serviceable
Condition of dishwasher: Appeared serviceable
Condition of range, cooktop: Appeared serviceable
Range, cooktop type: Natural gas
Condition of refrigerator: Appeared serviceable
Condition of built: Appeared serviceable
55) Repair/Maintain, Monitor - There was a dry water stain located below the kitchen skylight that should be monitored.
Photo
Photo 55-1 
56) - The kitchen is used for food preparation and often for entertainment. Kitchens typically include a stove, dishwasher, sink and other appliances. We try to test all appliances but in some cases (dishes in the dishwasher, food in the oven, etc.) we are not able to.
We test the cabinets to make sure they operate correctly as well as note the condition of the counter top. We check for plumbing leaks in the sink as well as dishwasher. The electric outlets near the sink should all have a GFCI circuit.
Bathrooms / Laundry / SinksTable of contents
Limitations: The following items are not included in this inspection: overflow drains for tubs and sinks; bidets, heated towel racks, saunas, steam generators. Any comments made regarding these items are as a courtesy only. Note that the inspector does not determine the adequacy of washing machine drain lines, washing machine catch pan drain lines, or clothes dryer exhaust ducts. The inspector does not operate water supply or shut-off valves for sinks, toilets, bidets, clothes washers, etc. due to the possibility of valves leaking or breaking when operated. The inspector does not determine if shower pans or tub and shower enclosures are water tight, or determine the completeness or operability of any gas piping to laundry appliances.
Location #A: 1st Floor
Location #B: 2nd Floor
Condition of counters: Appeared serviceable
Condition of cabinets: Appeared serviceable
Condition of sinks and related plumbing: Appeared serviceable
Condition of toilets: Appeared serviceable
Condition of bathtubs and related plumbing: Appeared serviceable, Bathtub located in Location B
Condition of shower(s) and related plumbing: Appeared serviceable, Shower in Location A
Condition of ventilation systems: Appeared serviceable, Exhaust fans located in both bathrooms.
Location: Dedicated Room Area, Within the bathroom at Location A
Condition of laundry facilities: Appeared serviceable
Gas supply for laundry equipment present: Not determined
240 volt receptacle for laundry equipment present: Not determined
57) Repair/Replace - The bathtub drain stopper mechanism at location #B was loose and/or difficult to operate. A qualified person should repair or replace as necessary.
58) Repair/Maintain - The caulk between the wall corner at location #B was deteriorated. A qualified person should repair as necessary.
Photo
Photo 58-1 The corner caulk was missing in this location of the bathtub at location B.
59) Repair/Maintain - Caulk around the tub's plumbing fixtures (faucets, spouts, escutcheon plates, etc.) at location #B was missing. A qualified person should repair as necessary.
Photo
Photo 59-1 
60) - Bathrooms can consist of many features from jacuzzi tubs and showers to toilets and bidets. Because of all the plumbing involved it is an important area of the house to look over. All bathrooms should have an exhaust fan, even if they have a window. If moisture is not removed from the air it can cause mildew, wallpaper and paint to peel, and other problems. All outlets in a bathroom should have a GFCI circuit to prevent shocks. All grout and caulking should always be monitored for cracks and resealing. Plumbing leaks can be both visible, as you will find underneath a sink, or not visible as you may discover in a wall behind a tub or shower faucet or drain. Always monitor for leaks. We have tried to identify as many issues as possible but some problems may be undetectable due to problems within the walls or under the flooring.
In a laundry we test the washer and dryer during operation. We are looking to see that all plumbing and drainage lines are leak free. We also examine the dryer exhaust/vent that should be a smooth metal type to avoid lent buildup. Again the outlet circuits should be GFCI rated.
Interior Rooms / AreasTable of contents
Limitations: The following items are not included in this inspection: security, intercom and sound systems; communications wiring; central vacuum systems; elevators and stair lifts; sources of obnoxious odors; cosmetic deficiencies due to normal wear and tear in wall, floor and ceiling surfaces and coverings, or in equipment; deficiencies relating to interior decorating; low voltage and gas lighting systems. Any comments made regarding these items are as a courtesy only. Note that the inspector does not evaluate any areas or items which require moving stored items, furnishings, debris, equipment, floor coverings, insulation or similar materials. The inspector does not test for asbestos, lead, radon, mold, hazardous waste, urea formaldehyde urethane, or any other toxic substance. Some items such as window operability are tested on a sampled basis. The client should be aware that paint may obscure wall and ceiling defects, floor coverings may obscure floor defects, and furnishings may obscure wall, floor and floor covering defects. If furnishings were present during the inspection, recommend a full evaluation of walls, floors and ceilings that were previously obscured when possible. Determining the cause of odors is not within the scope of this inspection.
Bedroom Locations within the home: There are [2!3!4] on the 1st Floor., There are [2!3!4]on the 2nd Floor., 1 bedroom on 1st Floor; 2 bedrooms on the 2nd Floor.
Exterior door material: Wood, Metal, Sliding glass
Condition of exterior entry doors: Appeared serviceable
Condition of interior doors: Appeared serviceable
Type of windows: Vinyl, Wood, Casement, Double hung, Fixed
Condition of windows: Appeared serviceable
Wall type or covering: Drywall
Condition of walls: Appeared serviceable
Ceiling type or covering: Drywall (Sheetrock)
Flooring type or covering: Carpet, Linoleum, Wood, Stone
Condition of flooring: Appeared serviceable
61) Repair/Replace, Evaluate - Significant cracks were found in some ceiling areas. This may be a structural concern, or an indication that settlement is ongoing. A qualified contractor should evaluate and repair as necessary.
Photo
Photo 61-1 This crack is located in the living room adjacent to the stairs to the 2nd floor. It should be repaired by a qualified contractor.
62) Repair/Maintain, Evaluate - Handrails at one or more flights of stairs were loose. This is a safety hazard. A qualified person should repair or replace as necessary and as per standard building practices.
Photo
Photo 62-1 
63) - The structural frame of the home rests on the foundation walls and holds up the floors, interior walls, and roof. Most homes in the US are framed with wood, but a few are built with a brick or block support. Recently homes are starting to be framed with metal. Once the frame and structure are properly designed and installed, little maintenance is needed except to protect the structure from water and insects.

The exterior walls are framed to support the structure, allow for window and door openings, and protect the structure from the elements. Most exterior walls are framed with 2 by 4 studs spaced 16 inches on center. The studs are braced in the corners and doubled around window and door openings. Special "headers" are placed over openings to support the weight above the opening. Exterior wall framing allows space for electrical, cable, telephone, heat distribution components and plumbing supply and waste lines. The framing also supports exterior siding or cladding and includes space for insulation.

Interior areas consist of bedrooms, baths, kitchen, laundry, hallways, foyer, and other open areas.   All exposed walls, ceilings and floors will be inspected.  Doors and windows will also be investigated for damage and normal operation. Although excluded from inspection requirements, we will inform you of obvious broken gas seals in windows.  Please realize that they are not always visible, due to temperature, humidity, window coverings, light source, etc. Your inspection will report visible damage, wear and tear, and moisture problems if seen. Personal items in the structure may prevent the inspector from viewing all areas, as the inspector will not move personal items.

An inspection does not include the identification of, or research for, appliances and other items that may have been recalled or have had a consumer safety alert issued about it. Any comments made in the report are regarding well known notices and are provided as a courtesy only. Product recalls and consumer product safety alerts are added almost daily by the Consumer Product Safety Commission. We recommend visiting the following Internet site if recalls are a concern to you: http://www.cpsc.gov.
Structural Pest FindingsTable of contents
Limitations: This report only includes findings from accessible and visible areas on the day of the inspection. In addition to the inaccessible areas documented in this report, examples of other inaccessible areas include: sub areas less than 18 inches in height; attic areas less than five feet in height, areas blocked by ducts, pipes or insulation; areas where locks or permanently attached covers prevent access; areas where insulation would be damaged if traversed; areas obscured by vegetation. All inaccessible areas are subject to infestation or damage from wood destroying organisms. The inspector does not move furnishings, stored items, debris, floor or wall coverings, insulation, or other materials as part of the inspection, nor perform destructive testing. Wood destroying organisms may infest, reinfest or become active at anytime. No warranty is provided as part of this inspection.
Visible evidence of active wood destroying insects: No
Visible evidence of active wood decay fungi: No
Visible evidence of past wood destroying insects: No
Visible evidence of past wood decay fungi: No
Visible evidence of damage by wood destroying insects: No
Visible evidence of damage by wood decay fungi: No
Visible evidence of conditions conducive to wood destroying organisms: No


Alliance Inspections, Inc.
"Done Once.....Done Right!"