Property Inspection Report

Client(s):  Sample Report
Property address:  Any Street
Anywhere, MD 21102
Inspection date:  Monday, July 2, 2018

This report published on Thursday, July 12, 2018 4:22:41 PM EDT

This report is the exclusive property of 4U Home, Inc. and the client(s) listed in the report title. Use of this report by any unauthorized persons is prohibited.

An inspection is intended to assist in the evaluation of the overall condition of a building. The inspection is based on observation of the visible and apparent condition of the building and its components on the date of the inspection. The results of this home inspection are not intended to make any representation regarding latent or concealed defects that may exist, and no warranty or guaranty is expressed or implied; your home inspector is not a licensed structural engineer or other professional whose license authorizes the rendering of an opinion as to structural integrity of a building or the condition of its components or systems, you may wish to seek the professional opinion of a licensed structural engineer or other professional regarding any possible defects or other observations set forth in this report.

Only home inspections performed by Maryland licensed home inspectors will be recognized as a valid home inspection under a real estate contract.


This report is prepared under the standards set forth in the "Maryland Standards of Practice", governing home inspections in the State of Maryland.

This reports may contain suggestions for repair, replacement, and/or further evaluation of areas and/or components of the inspected property. These items should be addressed (repaired, replaced,and/or evaluated) prior to the closing (transfer of ownership) of the home.

Photos in this report are representative of the type of concern listed in the description and are not intended to show all areas to which those concerns may apply.

Copyright 2018 4U Home, Inc.
All rights reserved. No part of this material may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying, recording, or by an information storage and retrieval system without permission in writing from the owner of this copyright. Inquiries should be addressed to 4U Home, Inc., 3545 Ellicott Mills Drive, Suite A-1, Ellicott City, MD 21043.

Not responsible for typographical errors

How to Read this Report
This report is organized by the property's functional areas.  Within each functional area, descriptive information is listed first and is shown in bold type.  Items of concern follow descriptive information. Concerns are shown and sorted according to these types:
Concern typeSafety ConcernDenotes a condition that is Unsafe and in need of Prompt Attention
Concern typeRepair/ReplaceRecommend repairing or replacing
Concern typeRepair/MaintainRecommend repair and/or maintenance
Concern typeEvaluateRecommend evaluation by a specialist
Concern typeCommentFor your information

Click here for a glossary of building construction terms.Contact your inspector If there are terms that you do not understand, or visit the glossary of construction terms at https://www.reporthost.com/glossary.asp



General Information
Table of contents

Report number: yee0702181400ag
Time started: 14:00
Inspector: Alan Grubb
Temperature during inspection: Hot
Ground condition: Dry
Recent weather: Sunny
Type of building: Single family
Buildings inspected: One house
Main entrance faces: Southeast
Occupied: No
Time finished: 17:00
Municipal Permits: Inspector does not review municipal and/or county permits which may be required to exchange systems or to modify structure. Compliance to local building authorities permits should be adhered to to ensure proper local standards were met. Recommend consulting with owner and/or local building authorities about any components and/or structure that may have been exchanged and/or modified and if proper permits were issued.

1) Microbial growths were found at one or more locations in the attic and/or the basement. It is beyond the scope of this inspection to identify what substance or organism this staining is. However such staining is normally caused by excessively moist conditions, which in turn can be caused by plumbing or building envelope leaks and/or substandard ventilation. These conducive conditions should be corrected before making any attempts to remove or correct the staining. For evaluation and possible mitigation, consult with a qualified industrial hygienist or mold/moisture mitigation specialist. For more information, visit:
http://www.cdc.gov/mold/
http://www.epa.gov/mold/

At enclosed sump pump
Photo
Photo 1-1 
Photo
Photo 1-2 
Photo
Photo 1-3 Attic
Photo
Photo 1-4 

2) Evidence of rodent activity was found in the form of urine stains in the attic. Consult with the property owner about this. A qualified person should make repairs to seal openings in the structure, set traps, and clean rodent waste as necessary. Recommend following guidelines in these Center for Disease Control articles:
http://www.cdc.gov/rodents/prevent_infestations/seal_up.html
http://www.cdc.gov/rodents/prevent_infestations/trap_up.html
http://www.cdc.gov/rodents/prevent_infestations/clean_up.html
Photo
Photo 2-1 
Photo
Photo 2-2 

Grounds
Table of contents

Limitations: Unless specifically included in the inspection, the following items and any related equipment, controls, electric systems and/or plumbing systems are excluded from this inspection: detached buildings or structures; fences and gates; retaining walls; underground drainage systems, catch basins or concealed sump pumps; swimming pools and related safety equipment, spas, hot tubs or saunas; whether deck, balcony and/or stair membranes are watertight; trees, landscaping, properties of soil, soil stability, erosion and erosion control; ponds, water features, irrigation or yard sprinkler systems; sport courts, playground, recreation or leisure equipment; areas below the exterior structures with less than 3 feet of vertical clearance; invisible fencing; sea walls, docks and boathouses; retractable awnings. Any comments made regarding these items are as a courtesy only.
Condition of driveway: Appeared serviceable
Driveway material: Asphalt
Condition of fences and gates: Appeared serviceable
Fence and gate material: Wood
Site profile: Minor slope
Condition of sidewalks and/or patios: Appeared serviceable
Sidewalk material: Poured in place concrete, Paving stones
Condition of decks, porches and/or balconies: Appeared serviceable
Deck, porch and/or balcony material: Wood
Condition of stairs, handrails and guardrails: Required repairs, replacement and/or evaluation (see comments below)
Exterior stair material: Wood
Condition of deck, patio and/or porch covers: Appeared serviceable
Condition of fences and gates: Required repairs, replacement and/or evaluation (see comments below)

3) The risers for stairs at one or more locations varied in height and pose a fall or trip hazard. Risers within the same flight of stairs should vary by no more than 3/8 inch. At a minimum, be aware of this hazard, especially when guests who are not familiar with the stairs are present. Recommend that a qualified contractor repair per standard building practices.
Photo
Photo 3-1 

4) Handrails at one or more flights of stairs were not graspable and posed a fall hazard. Handrails should be 1 1/4 - 2 inches in diameter if round, or 2 5/8 inches or less in width if flat. Recommend that a qualified person install graspable handrails or modify existing handrails per standard building practices.
Photo
Photo 4-1 

5) Soil was in contact with or close to wooden stairs at one or more locations. This is a conducive condition for wood-destroying organisms. Soil should be graded and/or removed so no wood-soil contact is present, if possible. Otherwise, installing products such as borate-based Impel rods may help to prevent infestation and damage. For more information, visit:
http://www.google.com/search?q=impel+rods
Photo
Photo 5-1 
Photo
Photo 5-2 

6) One or more fences were damaged or deteriorated and need repair. Recommend that a licensed contractor repair per standard building practices.

Many Nail Pops
Photo
Photo 6-1 

7) Wooden deck or porch surfaces were due for normal maintenance. Recommend that a qualified person clean and preserve as necessary. Where decks have been coated with a finish such as opaque stains or paint, it may be too difficult to strip the finish and apply anything but paint or opaque stain. Where transparent stain or penetrating oil has been applied in the past, recommend that a penetrating oil be used. For more information, visit:
http://www.google.com/search?q=penetrating+oil+decks
http://www.google.com/search?q=deck+maintenance
Photo
Photo 7-1 

8) All areas of the deck substructure were inaccessible due to permanently installed skirting. These areas couldn't be evaluated and are excluded from the inspection.
Photo
Photo 8-1 

Exterior and Foundation

Limitations: The inspector performs a visual inspection of accessible components or systems at the exterior. Items excluded from this inspection include below-grade foundation walls and footings; foundations, exterior surfaces or components obscured by vegetation, stored items or debris; wall structures obscured by coverings such as siding or trim. Some items such as siding, trim, soffits, vents and windows are often high off the ground, and may be viewed using binoculars from the ground or from a ladder. This may limit a full evaluation. Regarding foundations, some amount of cracking is normal in concrete slabs and foundation walls due to shrinkage and drying. Note that the inspector does not determine the adequacy of seismic reinforcement.
Condition of wall exterior covering: Appeared serviceable
Apparent wall structure: Wood frame
Wall covering: Vinyl, Stone or faux stone veneer
Condition of foundation and footings: Appeared serviceable
Apparent foundation type: Finished basement
Foundation/stem wall material: Poured in place concrete
Footing material (under foundation stem wall): Not determined (inaccessible or obscured)

9) The masonry (brick or stone) was deteriorated or damaged (cracks, missing brick/stone, Mortar) in some areas. Where cracks or openings are exposed, water can enter building envelope and may cause structural damage. Recommend that a licensed contractor repair as necessary. For example, by re-pointing mortar or replacing broken or missing masonry.
Photo
Photo 9-1 
Photo
Photo 9-2 

10) Some sections of siding were deteriorated, loose, split, warped, missing, damaged, substandard. Recommend that a qualified person repair, replace or install siding as necessary.
Photo
Photo 10-1 
Photo
Photo 10-2 
Photo
Photo 10-3 
Photo
Photo 10-4 
Photo
Photo 10-5 

11) One or more exhaust duct end caps were deteriorated. Their purpose is to prevent unconditioned air from entering the building, and keep out birds, rodents and bugs. Blocked ducts can cause fan motors and/or clothes dryers to overheat and can pose a fire hazard. Recommend that a qualified person repair or replace caps as necessary.
Photo
Photo 11-1 
Photo
Photo 11-2 

12) Vegetation such as trees, shrubs and/or vines was in contact with or close to the building exterior. Vegetation can serve as a pathway for wood-destroying insects and can retain moisture against the exterior after it rains. This is a conducive condition for wood-destroying organisms. Recommend pruning, moving or removing vegetation as necessary to maintain at least 6 inches of space between it and the building exterior. A 1-foot clearance is better.
Photo
Photo 12-1 

13) Soil was in contact with or less than 6 inches from siding or trim. Regardless of what material is used for siding, it should not be in contact with the soil. If made of wood, siding or trim will eventually rot. For other materials, ground or surface water can infiltrate siding or trim and cause damage to the wall structure. Wood-destroying insects are likely to infest and damage the wall structure. This is a conducive condition for wood-destroying organisms. Recommend grading or removing soil as necessary to maintain a 6-inch clearance. Note that damage from fungal rot and/or insects may be found when soil is removed, and repairs may be necessary.
Photo
Photo 13-1 

14) Soil was in contact with or less than 4 inches from brick, stone or faux stone veneer. For most residential installations of this type of veneer, this is a conducive condition for wood-destroying organisms. Weep holes may be covered. Condensed water behind the veneer may not be able to escape, and moisture can accumulate in the wood structure behind. Recommend grading and/or removing soil as necessary to maintain a 4-inch clearance.
Photo
Photo 14-1 

15) Some areas of the exterior paint or stain finish were incomplete and/or substandard (e.g. primed only, too few coats). Recommend that a qualified contractor prep (e.g. clean, scrape, sand, prime, caulk) and repaint or restain the exterior where necessary and per standard building practices. Any repairs needed to the siding or trim should be made prior to this.
Photo
Photo 15-1 

16) One or more minor cracks were found in the foundation. These didn't appear to be a structural concern, but recommend sealing them to prevent water infiltration and monitor them in the future. Numerous products exist to seal such cracks including hydraulic cement, non-shrinking grout, resilient caulks and epoxy sealants.
Photo
Photo 16-1 
Photo
Photo 16-2 

Roof

Limitations: The following items or areas are not included in this inspection: areas that could not be traversed or viewed clearly due to lack of access; solar roofing components. Any comments made regarding these items are made as a courtesy only. Note that the inspector does not provide an estimate of remaining life on the roof surface material, nor guarantee that leaks have not occurred in the roof surface, skylights or roof penetrations in the past. Regarding roof leaks, only active leaks, visible evidence of possible sources of leaks, and evidence of past leaks observed during the inspection are reported on as part of this inspection. The inspector does not guarantee or warrant that leaks will not occur in the future. Complete access to all roof and attic spaces during all seasons and during prolonged periods of all types of weather conditions (e.g. high wind and rain, melting snow) would be needed to do so. Regarding the roof drainage system, unless the inspection was conducted during and after prolonged periods of heavy rain, the inspector was unable to determine if gutters, downspouts and extensions performed adequately or were leak-free.
Limitations of age declaration:: The inspector cannot give an exact age of the roof surface by observation. It is recommend that the client seek a declaration by the seller and/or owner as to the correct age of the roof.
Roof inspection method: Viewed from eaves on ladder, Viewed from ground with binoculars, Viewed from windows
Condition of roof surface material: Appeared serviceable, No visible damage
Roof surface material: Asphalt or fiberglass composition shingles
Roof type: Gable
Apparent number of layers of roof surface material: One
Condition of exposed flashings: Required repair, replacement and/or evaluation (see comments below)
Condition of gutters, downspouts and extensions: Appeared serviceable
Gutter and downspout material: Metal
Gutter and downspout installation: Full
Limitations of age declaration:: The inspector cannot give an exact age of the roof surface by observation. It is recommend that the client seek a declaration by the seller and/or owner as to the correct age of the roof. This estimate of age is only a guideline for budgeting purposes and not a warranty of expectancy.

17) Kick-out flashing was missing at one or more locations. Such flashing should be located at the bottom of slopes where roof surfaces intersect with exterior walls above. It directs rainwater away from exterior walls and into gutters so that rainwater is less likely to run down the front surfaces of siding or flow behind siding. Recommend that a qualified contractor install kickout flashings where missing and per standard building practices.
Photo
Photo 17-1 

Attic and Roof Structure

Limitations: The following items or areas are not included in this inspection: areas that could not be traversed or viewed clearly due to lack of access; areas and components obscured by insulation. Any comments made regarding these items are made as a courtesy only. The inspector does not determine the adequacy of the attic ventilation system. Complete access to all roof and attic spaces during all seasons and during prolonged periods of all types of weather conditions (e.g. high/low temperatures, high/low humidity, high wind and rain, melting snow) would be needed to do so. The inspector is not a licensed engineer and does not determine the adequacy of roof structure components such as trusses, rafters or ceiling beams, or their spacing or sizing.
Attic inspection method: Traversed
Location of attic access point #A: Hallway
Attic access points that were opened and viewed, traversed or partially traversed: A
Condition of roof structure: Appeared serviceable
Roof structure type: Trusses
Condition of insulation in attic (ceiling, skylight chase, etc.): Appeared serviceable
Ceiling insulation material: Fiberglass loose fill
Vapor retarder: None visible
Condition of roof ventilation: Appeared serviceable
Roof ventilation type: Ridge vent(s)

18) The pull-down attic stairs were not insulated. Typically, such stairs that are not insulated also do not have any weatherstripping installed. Recommend that a qualified person install insulation and weatherstripping per standard building practices for better energy efficiency. For more information, visit:
http://www.google.com/search?q=insulate+attic+stairs
Photo
Photo 18-1 

Carport

Limitations: The inspector does not determine the adequacy of firewall ratings. Requirements for ventilation in garages vary between municipalities.
Condition of garage floor: Appeared serviceable

19) Minor cracks were found in the concrete slab floor. These are common and appeared to be only a cosmetic issue. Recommend that crack be sealed to prevent further water intrusion.
Photo
Photo 19-1 

Basement and/or Structure

Limitations: Structural components such as joists and beams, and other components such as piping, wiring and/or ducting that are obscured by under-floor insulation and/or wall insulation are also excluded from this inspection. Note that the inspector does not determine if support posts, columns, beams, joists, studs, trusses, etc. are of adequate size, spanning or spacing.

The inspector does not guarantee or warrant that water will not accumulate in the basement in the future. Access to the basement during all seasons and during prolonged periods of all types of weather conditions (e.g. heavy rain, melting snow) would be needed to do so. The inspector does not determine the adequacy of basement floor or stairwell drains, or determine if such drains are clear or clogged.

Note that all basement areas should be checked periodically for water intrusion, plumbing leaks and pest activity.
Condition of foundation and footings: Appeared serviceable
Foundation/stem wall material: Poured in place concrete
Condition of exterior entry doors: Appeared serviceable
Exterior door material: Sliding glass
Condition of floor substructure above crawl space: Required repairs, replacement and/or evaluation (see comments below)
Pier or support post material: Steel
Beam material: Steel
Floor structure: Solid wood joists
Condition of insulation underneath floor above: Not applicable, none installed

20) Handrails at one or more flights of stairs were missing. This is a potential fall hazard. Handrails should be installed at stairs with four or more risers or where stairs are greater than 30 inches high. Recommend that a licensed contractor install handrails where missing and per standard building practices.
Photo
Photo 20-1 

21) A door swung outward over one or more sets of stairs, and either no landing was installed, or the landing didn't extend at least 20 inches beyond the outermost swing area of the door. This a safety hazard since someone standing on the stairs can fall or be pushed backwards if the door is opened. Recommend that a licensed contractor repair per standard building practices.
Photo
Photo 21-1 
Photo
Photo 21-2 

Electric

Limitations: The following items are not included in this inspection: generator systems, transfer switches, surge suppressors, inaccessible or concealed wiring; underground utilities and systems; low-voltage lighting or lighting on timers or sensors. Any comments made regarding these items are as a courtesy only. Note that the inspector does not determine the adequacy of grounding or bonding, if this system has an adequate capacity for the client's specific or anticipated needs, or if this system has any reserve capacity for additions or expansion. The inspector does not operate circuit breakers as part of the inspection, and does not install or change light bulbs. The inspector does not evaluate every wall switch or receptacle, but instead tests a representative number of them per various standards of practice. When furnishings, stored items or child-protective caps are present some receptacles are usually inaccessible and are not tested; these are excluded from this inspection. Receptacles that are not of standard 110 volt configuration, including 240-volt dryer receptacles, are not tested and are excluded. The functionality of, power source for and placement of smoke and carbon monoxide detectors is not determined as part of this inspection. Upon taking occupancy, proper operating and placement of smoke and carbon monoxide detectors should be verified and batteries should be changed. These devices have a limited lifespan and should be replaced every 10 years. The inspector attempts to locate and evaluate all main and sub-panels. However, panels are often concealed. If panels are found after the inspection, a qualified electrician should evaluate and repair if necessary. The inspector attempts to determine the overall electrical service size, but such estimates are not guaranteed because the overall capacity may be diminished by lesser-rated components in the system. Any repairs recommended should be made by a licensed electrician.
Electric service condition: Appeared serviceable
Primary service type: Underground
Number of service conductors: 2
Service voltage (volts): 120-240
Estimated service amperage: 200
Primary service overload protection type: Circuit breakers
Service entrance conductor material: Stranded aluminum
Main disconnect rating (amps): 200
System ground: Not determined, not readily apparent
Smoke alarms installed: Yes, audible sound only, no smoke testing
Carbon monoxide alarms installed: No, recommend install
Condition of main service panel: Appeared serviceable
Location of main service panel #A: Basement
Location of main disconnect: Breaker at top of main service panel
Condition of branch circuit wiring: Serviceable
Branch circuit wiring type: Non-metallic sheathed, Copper, Aluminum multi-strand

22) One or more ground fault circuit interrupter (GFCI) circuit breakers wouldn't trip or wouldn't reset when tested. GFCI breakers reduce the chance of shock when using equipment in wet areas. This is a potential shock hazard. Recommend that a qualified electrician evaluate and repair as necessary.
Photo
Photo 22-1 

23) One or more ground fault circuit interrupter (GFCI) receptacles (outlets) wouldn't trip with a test instrument at the exterior. This is a potential shock hazard. Recommend that a qualified electrician evaluate and repair as necessary.
Photo
Photo 23-1 

24) One or more light fixtures installed outside were deteriorated. This is a potential shock and/or fire hazard. Recommend that a qualified electrician repair as necessary.
Photo
Photo 24-1 
Photo
Photo 24-2 

25) Wire splices were exposed and were not contained in a covered junction box. This is a potential shock or fire hazard. Recommend that a qualified electrician repair per standard building practices. For example, by installing permanently mounted junction boxes with cover plates where needed to contain wiring splices.
Photo
Photo 25-1 

26) One or more electric receptacles (outlets) and/or the boxes in which they were installed were loose and/or not securely anchored. Wire conductors can be damaged due to repeated movement and/or tension on wires, or insulation can be damaged. This is a shock and fire hazard. Recommend that a qualified electrician repair as necessary.
Photo
Photo 26-1 

27) One or more cover plates for switches, receptacles (outlets) or junction boxes were missing or broken. These plates are intended to contain fire and prevent electric shock from occurring due to exposed wires. Recommend that a licensed contractor install cover plates where necessary.
Photo
Photo 27-1 
Photo
Photo 27-2 

Plumbing System

Limitations: The following items are not included in this inspection: private/shared wells and related equipment; private sewage disposal systems; hot tubs or spas; main, side and lateral sewer lines; gray water systems; pressure boosting systems; trap primers; incinerating or composting toilets; all parts of fire suppression systems; water softeners, conditioners or filtering systems; plumbing components concealed within the foundation or building structure, or in inaccessible areas such as below tubs; underground utilities and systems; overflow drains for tubs and sinks; backflow prevention devices. Any comments made regarding these items are as a courtesy only. Note that the inspector does not operate water supply or shut-off valves due to the possibility of valves leaking or breaking when operated. The inspector does not test for lead in the water supply, the water pipes or solder, does not determine if plumbing and fuel lines are adequately sized, and does not determine the existence or condition of underground or above-ground fuel tanks.
Condition of service and main line: Appeared serviceable
Location of main water meter: Basement
Location of main water shut-off: Basement
Water service: Public
Service pipe material: Copper
Condition of supply lines: Appeared serviceable
Supply pipe material: Copper
Condition of drain pipes: Appeared serviceable
Drain pipe material: PVC (Polyvinyl chloride)
Condition of waste lines: Appeared serviceable
Waste pipe material: PVC (Polyvinyl chloride)
Location(s) of plumbing clean-outs: Not determined (obscured, inaccessible or none found)
Vent pipe condition: Appeared serviceable
Vent pipe material: PVC (Polyvinyl chloride)
Sump pump installed: Yes
Condition of sump pump: Not determined (inaccessible or obscured)

28) One or more hose bibs (outside faucets) appeared to be inoperable. No water flowed from the bib(s) when turned on. This may be due to a shut-off valve being turned off. Note that the inspector does not operate shut-off valves. Recommend consulting with the property owner about inoperable hose bibs, and if necessary have a licensed plumber make repairs.
Photo
Photo 28-1 

29) One or more hose bib (outside faucets) handles were not secured to home and twist. This could break joints causing leaks. Recommend that a licensed contractor and/or plumber replace handles or make repairs as necessary.
Photo
Photo 29-1 
Photo
Photo 29-2 

30) The inspector was unable to fully evaluate the sump pump because it was inaccessible. Its condition was not determined. Recommend that conditions that prevented evaluation be corrected, and that a licensed contractor test the pump and make repairs if necessary.
Photo
Photo 30-1 
Photo
Photo 30-2 

31)   Location
Photo
Photo 31-1 Main Water Shut Off

32)   The back-flow valve connected to the water supply system appears to have exceeded its functional life. These devices protect the potable water system from being contaminated. According to the manufacturer's recommendations and most local water authorities, these units need replacement every five years. Recommend evaluation by a licensed plumber for replacement.
Photo
Photo 32-1 

Water Heater

Limitations: Evaluation of and determining the adequacy or completeness of the following items are not included in this inspection: water recirculation pumps; solar water heating systems; Energy Smart or energy saver controls; catch pan drains. Any comments made regarding these items are as a courtesy only. Note that the inspector does not provide an estimate of remaining life on water heaters, does not determine if water heaters are appropriately sized, or perform any evaluations that require a pilot light to be lit or a shut-off valve to be operated.
Condition of water heater: Appeared serviceable
Type: Tank
Energy source: Natural gas
Capacity (in gallons): 40
Manufacturer: American
Estimated age: 7
Location of water heater: Basement
Temperature-pressure relief valve installed: Yes
Is Thermal Expansion Tank Installed: Yes
Condition of burners: Appeared serviceable
Condition of venting system: Appeared serviceable
Condition of combustion air supply: Appeared serviceable

33) The temperature-pressure relief valve drain line was too short. This is a potential safety hazard due to the risk of scalding if someone is standing next to the water heater when the valve opens. Recommend that a qualified plumber repair per standard building practices. For example, by extending the drain line to within 6 inches of the floor, or routing it to drain outside. For more information, visit:
http://www.reporthost.com/_docs/TPvalve.pdf
Photo
Photo 33-1 

34) Significant corrosion or rust was found at the supply pipes or fittings. This can indicate past leaks, or that leaks are likely to occur in the future. Recommend that a qualified plumber evaluate and replace components or make repairs as necessary.
Photo
Photo 34-1 

35) A larger expansion tank installed on water heater, had no support strapping. Tanks when unsupported can cause leaks at the pipe joints due to stress on these areas. Recommend a licensed plumber install support strapping to tank as needed to prevent stress on connection points.
Photo
Photo 35-1 

36) Location/Serial Number of unit.
Photo
Photo 36-1 
Photo
Photo 36-2 

Fuel Systems

Condition of fuel system: Appeared serviceable
Visible fuel storage systems: in yard
Location of main fuel shut-off valve: At gas meter

37) Location
Photo
Photo 37-1 

Heating, Ventilation and Air Condition (HVAC)

Limitations: The following items are not included in this inspection: humidifiers, dehumidifiers, electronic air filters; solar, coal or wood-fired heat systems; thermostat or temperature control accuracy; reversing valve on heat pumps and timed functions; heating components concealed within the building structure or in inaccessible areas; underground utilities and systems; safety devices and controls (due to automatic operation). Any comments made regarding these items are as a courtesy only. Note that the inspector does not provide an estimate of remaining life on heating or cooling system components, does not determine if heating or cooling systems are appropriately sized, does not test coolant pressure, or perform any evaluations that require a pilot light to be lit, a shut-off valve to be operated, a circuit breaker to be turned "on" or a serviceman's or oil emergency switch to be operated. It is beyond the scope of this inspection to determine if furnace heat exchangers are intact and free of leaks. Condensation pans and drain lines may clog or leak at any time and should be monitored while in operation in the future. Where buildings contain furnishings or stored items, the inspector may not be able to verify that a heat source is present in all "liveable" rooms (e.g. bedrooms, kitchens and living/dining rooms).
General heating system type(s): Forced air
General heating distribution type(s): Ducts and registers
Location of forced air furnace: Basement
Condition of cooling system and/or heat pump Condenser: Appeared serviceable
Type: Split system
Manufacturer: Payne
Estimated age: 1
Condition of forced air heating/(cooling) system: Appeared serviceable
Fuel Type of Forced Air Furnace: Natural Gas
Forced air heating system manufacturer: Payne
Estimated age of forced air furnace: 1
Manufacturer: ADP
Condition of furnace filters: Appeared serviceable
Location for forced air filter(s): At base of air handler
Limitations: HVAC Distribution: By the Maryland SoPs (Standards of Practice) of home inspection, it is beyond the scope to determine the adequacy and/or condition of heating, venting and air conditioning components. This includes the duct work, venting or lack there of to accommodate heat and/or air conditioning in the home. The inspector based on conditions on the day of inspection may or may not be able to determine the proper conditioning of all rooms. Measurement of proper air flow and conditioning of rooms requires equipment and calculations that your inspector would not have nor address doing a standard Maryland home inspection. Recommend that any system beyond twenty years old, a new system in a home recently remodeled and/or system that has been modified be evaluated by a licensed HAVC professional with equipment to determine proper air volume and installation.
Condition of forced air ducts and registers: Appeared serviceable
Condition of combustion air supply: Appeared serviceable
Condition of controls: Appeared serviceable

38) Recommend replacing or washing HVAC filters upon taking occupancy depending on the type of filters installed. Regardless of the type, recommend checking filters monthly in the future and replacing or washing them as necessary. How frequently they need replacing or washing depends on the type and quality of the filter, how the system is configured (e.g. always on vs. "Auto"), and on environmental factors (e.g. pets, smoking, frequency of house cleaning, number of occupants, the season).
Photo
Photo 38-1 

39) The covers for one or more heating and/or cooling system air filters were missing. Unfiltered air can enter the return air supply and reduce indoor air quality. Recommend that a qualified person repair as necessary.
Photo
Photo 39-1 

40) Location/Serial Number of unit.
Photo
Photo 40-1 
Photo
Photo 40-2 
Photo
Photo 40-3 
Photo
Photo 40-4 

Fireplaces, Stoves, Chimneys and Flues

Limitations: The following items are not included in this inspection: coal stoves, gas logs, chimney flues (except where visible). Any comments made regarding these items are as a courtesy only. Note that the inspector does not determine the adequacy of drafting or sizing in fireplace and stove flues, and also does not determine if prefabricated or zero-clearance fireplaces are installed in accordance with the manufacturer's specifications. The inspector does not perform any evaluations that require a pilot light to be lit, and does not light fires. The inspector provides a basic visual examination of a chimney and any associated wood burning device. The National Fire Protection Association has stated that an in-depth Level 2 chimney inspection should be part of every sale or transfer of property with a wood-burning device. Such an inspection may reveal defects that are not apparent to the home inspector who is a generalist.
Condition of wood-burning fireplaces, stoves: Appeared serviceable

41) One or more wood-burning fireplaces or stoves were found at the property. When such devices are used, they should be professionally inspected and cleaned annually to prevent creosote build-up and to determine if repairs are needed. The National Fire Protection Association states that a "Level 2" chimney inspection should be performed with every sale or transfer of property with a wood-burning device. Recommend consulting with the property owner about recent and past servicing and repairs to all wood-burning devices and chimneys or flues at this property. Recommend that a qualified specialist evaluate all wood-burning devices and chimneys, and clean and repair as necessary. Note that if a wood stove insert is installed, it may need to be removed for such an evaluation. For more information, search for "chimney inspection" at:
http://www.csia.org/
Photo
Photo 41-1 

Kitchen

Limitations: Testing of kitchen appliances includes basic function but does not include determining if the appliance is adequately performing its intended functions and it does not include determining if sensors, thermostats and other devices are accurately calibrated. The following items are not included in this inspection: hot water dispensers and water filters; appliance timers, clocks, cook functions, self and/or continuous cleaning operations, thermostat or temperature control accuracy, and lights. Any comments made regarding these items are as a courtesy only. Note that the inspector does not provide an estimate of the remaining life of appliances, and does not determine the adequacy of operation of appliances. The inspector does not note appliance manufacturers, models or serial numbers and does not determine if all appliances are subject to recalls. Areas and components behind and obscured by appliances are inaccessible and excluded from this inspection.
Permanently installed kitchen appliances present during inspection: Range, Oven, Dishwasher, Microwave oven
Condition of counters: Appeared serviceable
Condition of cabinets: Appeared serviceable
Condition of sinks and related plumbing: Appeared serviceable
Condition of under-sink food disposal: N/A (none installed)
Condition of dishwasher: Required repair, replacement and/or evaluation (see comments below)
Condition of range, cooktop: Appeared serviceable
Range, cooktop type: Electric
Condition of refrigerator: Appeared serviceable
Condition of built in Microwave Oven: Appeared serviceable

42) The dishwasher wasn't securely attached to the counter or cabinets. Fasteners were loose. Recommend that a qualified person install fasteners per standard building practices.
Photo
Photo 42-1 

Bathrooms, Laundry and Sinks

Limitations: The following items are not included in this inspection: overflow drains for tubs and sinks; heated towel racks, saunas, steam generators, clothes washers, clothes dryers. Any comments made regarding these items are as a courtesy only. Note that the inspector does not determine the adequacy of washing machine drain lines, washing machine catch pan drain lines, or clothes dryer exhaust ducts. The inspector does not operate water supply or shut-off valves for sinks, toilets, bidets, clothes washers, etc. due to the possibility of valves leaking or breaking when operated. The inspector does not determine if shower pans or tub and shower enclosures are water tight, or determine the completeness or operability of any gas piping to laundry appliances.
Location #A: 3/4 bath, basement
Location #B: Full bath, second floor
Location #F: Laundry room/area
Gas supply for laundry equipment present: Yes
240 volt receptacle for laundry equipment present: Yes

43) No caulk was installed around the base of the toilet at location(s) #B where fastened to the floor. Caulk should be applied approximately 3/4 of the way around the toilet base at the front for sanitary purposes and to prevent water intrusion. The back should be left uncaulked so water can escape if a leak ever occurs. Recommend that a qualified person caulk around the toilet base(s) per standard building practices.
Photo
Photo 43-1 

44) Rubber water supply hoses were installed at the clothes washer. These hoses are prone to bursting when deteriorated, which can result in flooding and significant water damage. Recommend upgrading to braided, stainless steel hoses.
Photo
Photo 44-1 

45) Note washer and dryer are operated to evaluate proper installation and for leaks in supply and drain (washer) and power supply and air exhaust (dryer) only. No evaluation is made on the systems ability to perform its duty, mechanical function or on the age of either system.
Photo
Photo 45-1 

Interior, Doors and Windows

Limitations: The following items are not included in this inspection: security, intercom and sound systems; communications wiring; central vacuum systems; elevators and stair lifts; cosmetic deficiencies such as nail-pops, scuff marks, dents, dings, blemishes or issues due to normal wear and tear in wall, floor and ceiling surfaces and coverings, or in equipment; deficiencies relating to interior decorating; low voltage and gas lighting systems. Any comments made regarding these items are as a courtesy only. Note that the inspector does not evaluate any areas or items which require moving stored items, furnishings, debris, equipment, floor coverings, insulation or similar materials. The inspector does not test for asbestos, lead, radon, mold, hazardous waste, urea formaldehyde urethane, or any other toxic substance. Some items such as window, drawer, cabinet door or closet door operability are tested on a sampled basis. The client should be aware that paint may obscure wall and ceiling defects, floor coverings may obscure floor defects, and furnishings may obscure wall, floor and floor covering defects. If furnishings were present during the inspection, recommend a full evaluation of walls, floors and ceilings that were previously obscured when possible. Determining the cause and/or source of odors is not within the scope of this inspection.

46) One or more screen doors were deteriorated. Recommend that a qualified person evaluate and repair or replace as necessary.
Photo
Photo 46-1 
Photo
Photo 46-2 

This report is prepared under the standards set forth in the "Maryland Standards of Practice", governing home inspections in the State of Maryland.

Re-Inspection: Any return to property for follow up and/or completion due to inaccessible areas, repairs made, and/or request of client is at the discretion of the Inspector and will be charged a re-inspection fee at the prevailing rates in effect at that time.

Copyright 2018 4U Home, Inc.
All rights reserved. No part of this material may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying, recording, or by an information storage and retrieval system without permission in writing from the owner of this copyright. Inquiries should be addressed to 4U Home, Inc., 3545 Ellicott Mills Drive, Suite A-1, Ellicott City, MD 21043.

Not responsible for typographical errors