Inspector: Rick Richardson
WSDA License # 72463

 

Sample 200700302 WSDA # ICN-0000OR000
Client(s): Small Investment for Future Security
Property address: 100 Dream St., Paridise, USA
Inspection date: Wednesday February 30, 2005
This report published on 3/2/2007 3:23:25 PM PST

View summary page

This report is the exclusive property of this inspection company and the client(s) listed in the report title. Use of this report by any unauthorized persons is prohibited.

 
How to Read this Report
This report is organized by the property's functional areas.  Within each functional area, descriptive information is listed first and is shown in bold type.  Items of concern follow descriptive information. Concerns are shown and sorted according to these types:
SafetyPoses a risk of injury or death 
Repair/ReplaceRecommend repairing or replacing 
Repair/MaintainRecommend repair and/or maintenance 
Minor defectCorrection likely involves only a minor expense 
MaintainRecommend ongoing maintenance 
EvaluateRecommend evaluation by a specialist 
MonitorRecommend monitoring in the future 
CommentFor your information 

Structural Pest Inspection Concerns
Items of concern relating to the structural pest inspection are shown as follows:
WDO/WDI InfestationEvidence of infestation of wood destroying insects or organisms (Live or dead insect bodies, fungal growth, etc.) 
WDO/WDI DamageDamage caused by wood destroying insects or organisms (Rot, carpenter ant galleries, etc.) 
WDO/WDI Conducive
conditions
Conditions conducive for wood destroying insects or organisms (Wood-soil contact, shrubs in contact with siding, roof or plumbing leaks, etc.) 

Click here for a glossary of building construction terms.  Contact your inspector if there are terms that you do not understand, or visit the glossary of construction terms at http://www.reporthost.com/glossary.asp

Table of Contents
General information
Exterior
Roof
Electric service
Water heater
Heating and cooling
Plumbing and laundry
Crawl space
Kitchen
Bathrooms
Interior rooms

 

General information 
Return to table of contents

Report number: 200700302
Type of building: Single family, Manufactured home
Age of building: Unknown
Time started: 1:00 pm
Time finished: 3:00 pm
Inspection Fee: $
Payment method: Check #
Present during inspection: Realtor, Lender, Appraiser, Client's representative
Occupied: No
Weather conditions: Cloudy
Temperature: Cool 45*
Ground condition: Damp
Front of structure faces: East
Main entrance faces: East
The following items are excluded from this inspection: Irrigation system, Shed, Playground equipment

 

Exterior 
Return to table of contents

Footing material: Poured in place concrete
Foundation material: Steel frame on concrete block piers
Apparent wall structure: Wood frame
Wall covering: Composition wood panels
Driveway material: Poured in place concrete
Sidewalk material: Poured in place concrete
Exterior door material: Solid core steel


1)   The electric receptacle in the carport area appears to have no power. The waterproof cover is also missing. This is a safety hazard due to the risk of shock and fire. The cover should be replaced.
Recommend asking the property owner(s) about this. Switches may need to be operated to make some receptacles energized. If necessary, a qualified electrician should evaluate and make repairs as necessary.


2)   One or more outside faucets are missing backflow prevention devices[/url]. These devices reduce the likelihood of polluted or contaminated water entering the potable water supply. This condition can occur when an outside faucet is left in the "on" position with a hose connected and the sprayer head turned off. When pressure in the system fluctuates, water can be drawn back into the water supply pipes from the house. If a chemical sprayer is being used with the hose, those chemicals can enter the water supply pipes.

Recommend installing backflow prevention devices on all exterior hose bibs where missing. They are available at most home improvement stores and are easily installed. For more information, visit: http://edis.ifas.ufl.edu/BODY_AE079


3)   One or more hornet, bee and/or wasp nests were found. These can pose a safety hazard. Nest(s) should be removed as necessary.
Photo 32  


4) The trim located on the lower edge of the siding is deteriorating. The paint has deteriorated and has allowed the composite material to absorb moisture. This is a conductive condition for WDO's.
Recommend A qualified contractor evaluate and make repairs and/or replace trim as necessary to prevent water and vermin intrusion.
Photo 31   Bottom Trim


5) Fascia boards are deteriorated in one or more areas. The Fascia is made from a composite material. The paint has deteriorated and has allowed the Fascia to absorb moisture. This is a conductive condition for WDO's.
Recommend A qualified contractor evaluate and make repairs as necessary.
Photo 12   Fascia board edge


6)   Fences and/or gates are damaged and/or deteriorated in some areas. A qualified contractor should evaluate and make repairs or replace sections as necessary.
Photo 2   Border Fence
Photo 3   Border Fence
Photo 4   Border Fence
Photo 5   Border Fence


7)   The Soffit is damaged on the west side of the house near the sliding door.
Recommend A qualified contractor evaluate and make repairs as necessary.
Photo 13   Damage to soffit


8) There are no gutters or downspouts installed on this house. This is consistent with many of the homes in the area. The lack of gutters and downspouts could result in water accumulating around the structure's foundation and crawl spaces. Accumulated water is a conducive condition to wood destroying insects and organisms, and may also cause the foundation to settle and possibly fail over time.
Recommend A qualified contractor install gutters and downspouts Also, extensions such as splashblocks or tie-ins to underground drain lines should be installed as necessary to carry rain water away from the house.


9)   The crawl space access cover is not secure. Animals such as vermin or pets may enter the crawl space and nest, die and/or leave feces and urine.
Recommend Securing the cover.


10) Soil is in contact with plywood skirting. The wood skirting is deteriorated in some areas. This is a conducive condition for wood destroying insects and organisms. The wood skirting is lined with heavy plastic on the inside toward the crawl space. The inspector was not able to properly evaluate the condition of the skirting without damaging the lining.
Recommend the skirting material be replaced with a none conductive material.
Photo 30  


11) Caulk is missing or deteriorated in some areas and should be replaced and/or applied where necessary. For more information on caulking, visit The Ins and Outs of Caulking.


12)   One or more light fixtures appear to be inoperable. Recommend further evaluation by replacing bulb(s) and/or consulting with the property owner(s). Repairs or replacement of the light fixture(s) by a qualified electrician may be necessary.


13)   Minor cracks were found in the driveway. However they don't appear to be a structural concern and no trip hazards were found. No immediate action is recommended.
Photo 34  


14)   Minor cracks were found in one or more sidewalk or patio sections. However they don't appear to be a structural concern and no trip hazards were found. No immediate action is recommended.
Photo 29   Patio

 

Roof 
Return to table of contents

Roof inspection method: Traversed
Roof type: Gable
Roof covering: Asphalt or fiberglass composition shingles
Estimated age of roof: 14/18
Gutter & downspout material: None
Roof ventilation: Adequate


15) One or more roof vents have sealant that is deteriorating.

Recommend having sealant applied to needed areas.
Photo 8   Roof


16) Industry standards rate asphalt or fiberglass composition roof surfaces at 20 years. The roof surface material appears to be in good condition at this time.
The client may chose to have a qualified roofing contractor evaluate for a "5 year roof certificate"
Photo 6   Roof
Photo 7   Roof

 

Electric service 
Return to table of contents

Primary service type: Underground
Primary service overload protection type: Circuit breakers
Service amperage (amps): 200
Service voltage (volts): 120/240
Location of main service switch: Westside/outside
Location of sub panels: Laundry/Utility room
Location of main disconnect: Breaker at bottom of main service panel
Service entrance conductor material: Aluminum
System ground: Ground rod(s) in soil
Main disconnect rating (amps): 200
Branch circuit wiring type: Non-metallic sheathed, Copper
Solid strand aluminum branch circuit wiring present: No
Smoke detectors present: Yes

 

Water heater 
Return to table of contents

Estimated age: 14 yrs
Type: Tank
Energy source: Electricity
Capacity (in gallons): 40
Manufacturer: Rheem
Model: 71-400
Water temperature (degrees Fahrenheit): 116*


17)   The estimated useful life for most water heaters is 8 to 12 years. This water heater appears to be at this age or older and may need replacing at any time. Recommend budgeting for a replacement in the near future.
Photo 17   Water heater


18)   No water supply shut-off valve is visible for the water heater. A shut-off valve allows the supply to the water heater to be turned off when the water heater needs repair or replacement, while allowing the remainder of the plumbing system to be operable (toilets, sinks, etc.). Recommend having a qualified, licensed plumbing contractor determine if a water supply shut-off valve exists, and install one if it is missing.


19) The temperature-pressure relief valve drain line is routed so as to empty into the crawl space. Water may accumulate in the crawl space if the valve develops a leak. A qualified plumber should re-route the drain line so as to drain outside.

 

Heating and cooling 
Return to table of contents

Estimated age: 14 yrs
Primary heating system energy source: Electric
Primary heat system type: Forced air
Primary A/C energy source: Electric
Primary Air conditioning type: Split system
Distribution system: Sheet metal ducts
Manufacturer: Coleman
Model: 3500A816
Filter location: At the top of the furnace
Last service date: Unknown


20)   Dirt and/or dust are visible in one or more sections of supply and/or return air ducts. This can be a health hazard, especially for those with allergies or respiratory problems. The Environmental Protection Association (EPA) recommends considering having ducts professionally cleaned when "ducts are clogged with excessive amounts of dust and debris and/or particles are actually released into the home from your supply registers". At a minimum, the visible debris should be thoroughly cleaned. Recommend having a qualified contractor clean the ducts. For more information on duct cleaning in relation to indoor air quality, visit: http://www.epa.gov/iaq/pubs/airduct.html
Photo 18   Return air vent


21)   Insulation on one or more heating/cooling ducts in unconditioned spaces is damaged and/or deteriorated. The duct running from the furnace side of the double wide manufactured home to the adjoining side is damaged. The damage appears to be effecting the airflow at the registers. A qualified contractor should evaluate and replace insulation and/or ducts as necessary and as per standard building practices.


22)   The air handler's filter(s) are loose or not securely installed. As a result, unfiltered air will flow through the system. The heating/cooling equipment service life and the indoor air quality may be reduced. A qualified contractor should make repairs as necessary, such as repairing or installing guides or retaining devices so filter(s) are securely installed with minimal gaps at edges.


23)   The last service date of this system appears to be more than one year ago, or the inspector was unable to determine the last service date. The client(s) should ask the property owner(s) when it was last serviced. If unable to determine the last service date, or if this system was serviced more than one year ago, a qualified heating and cooling contractor should inspect, clean, and service this system, and make repairs if necessary. This servicing should be performed annually in the future.


24)   Air handler filter(s) are dirty and should be replaced now. They should be checked monthly in the future and replaced as necessary.


25)   The estimated useful life for most forced air furnaces is 15 to 20 years. This furnace appears to be approaching this age and may need replacing at any time. Recommend having the system serviced and evaluated by a qualified heating and cooling contractor.


26)   The estimated useful life for air conditioning compressors is 8 to 15 years. This unit appears to be approaching this age and may need replacing at any time. Recommend having a qualified heating and cooling contractor service and evaluate.


27)   The outdoor air temperature was below 60 degrees Fahrenheit during the inspection. Because of this, the inspector was unable to operate and fully evaluate the cooling system.

 

Plumbing and laundry 
Return to table of contents

Water pressure (psi): 78 psi
Location of main water shut-off valve: Curbside
Location of main water meter: Curbside
Water service: Public
Service pipe material: Not visible
Supply pipe material: Polybutylene
Vent pipe material: Plastic
Drain pipe material: Plastic
Waste pipe material: Plastic


28) Plumbing supply lines appear to be made of Polybutylene. Polybutylene is a plastic material used extensively during the 1980s and 1990s that has proven to be more prone to leakage than other types of supply piping systems like copper. Recommend reviewing any disclosure statements if available for comments on leaks in the water supply system.

A class action lawsuit has been filed regarding this material that requires the manufacturers to cover piping systems installed between Jan. 1, 1978 through July 31, 1995. For more information on the class action lawsuit, visit http://www.pbpipe.com/index1.htm , or call the Plumbing Claims Group at (800) 356-3496 for more information.
Photo 16   Laundry

 

Crawl space 
Return to table of contents

Inspection method: Traversed
Insulation material underneath floor above: Fiberglas roll or batt
Pier or support post material: Concrete
Beam material: Steel
Floor structure above: Not visible
Vapor barrier present: Yes


29)   Some wiring is loose, unsupported, or inadequately supported. Standard building practices require non-metallic sheathed wiring to be trimmed to length, attached to runners or to solid backing with fasteners at intervals of 4-1/2 ft. or less. Fasteners should be installed within 12 inches of all enclosures. A qualified, licensed electrician should evaluate and repair as necessary. For example, trim wire to length and/or install staples as needed.


30) Evidence of prior water intrusion was found in one or more sections of the crawl space. For example, sediment stains on the vapor barrier or foundation, and/or efflorescent on the foundation. Accumulated water is a conducive condition for wood destroying insects and organisms and should not be present in the crawl space. The client(s) should review any disclosure statements available and ask the property owner(s) about past accumulation of water in the crawl space. The crawl space should be monitored in the future for accumulated water, especially after heavy and/or prolonged periods of rain. If water is found to accumulate, a qualified contractor who specializes in drainage issues should evaluate and repair as necessary. Typical repairs for preventing water from accumulating in crawl spaces include:

  • Repairing, installing or improving rain run-off systems (gutters, downspouts and extensions or drain lines)
  • Improving perimeter grading
  • Repairing, installing or improving underground footing and/or curtain drains

    Ideally, water should not enter crawl spaces, but if water must be controlled after it enters the crawl space, then typical repairs include installing trenches, gravity drains and/or sump pump(s) in the crawl space.


    31)   Insulation under the floor in the crawlspace is damaged, deteriorated, or has fallen down. A qualified contractor should make repairs as necessary to restore the insulation to its original rating.


    32)   Some crawl space areas were inaccessible due to low height (less than 18 inches), ductwork or pipes blocking, standing water, and/or stored items. These areas are excluded from this inspection.

     

    Return to table of contents


    33)   One or more electric receptacles that serve countertop surfaces within six feet of a sink appear to have no ground fault circuit interrupter (GFCI) protection. This is a safety hazard due to the risk of shock. A qualified electrician should evaluate to determine if GFCI protection exists, and if not, repairs should be made so that all receptacles that serve countertop surfaces within six feet of sinks have GFCI protection. For example, install GFCI receptacles or circuit breaker(s) as needed.


    34)   The dishwasher's door seal is damaged, deteriorated, misaligned or otherwise does not seal well. A qualified appliance technician should evaluate and repair as necessary.
    Photo 14   Leak dishwasher
    Photo 15   Kitchen


    35)   One or more stove top burners are inoperable. A qualified appliance technician should evaluate and repair as necessary.


    36)   The refrigerator and/or freezer door handle(s) are loose and/or missing. Repairs should be made as necessary, and by a qualified appliance technician if necessary, such as tightening or replacing handles.


    37)   The range hood exhaust system filter needs cleaned or be replaced as necessary.


    38)   The under-sink food disposal is significantly corroded and/or appears to be near or at the end of its service life. Recommend having a qualified contractor or plumber replace the under-sink food disposal.


    39)   The oven light is inoperable. Recommend replacing bulb or having repairs made if necessary by a qualified appliance technician.


    40)   One or more kitchen appliances appear to be near, at, or beyond their intended service life of 10 to 15 years. Recommend budgeting for replacements as necessary.

     

    Return to table of contents


    41)   One or more electric receptacles that serve countertop surfaces within six feet of a sink appear to have no ground fault circuit interrupter (GFCI) protection. This is a safety hazard due to the risk of shock. A qualified electrician should evaluate to determine if GFCI protection exists, and if not, repairs should be made so that all receptacles that serve countertop surfaces within six feet of sinks have GFCI protection. For example, install GFCI receptacles or circuit breaker(s) as needed.


    42) Master Bath exhaust fan is inoperable or provides inadequate air flow. Moisture may accumulate as a result. A qualified contractor should evaluate and replace the fan or make repairs as necessary.


    43)   Main Bath exhaust fan is noisy or vibrates excessively. A qualified contractor should evaluate and replace the fan(s) or make repairs as necessary.
    Photo 21   Master Bath


    44) The bathtub faucet assembly is not secured to the wall structure in the Master Bath, The tub surround is partially detatched. Recommend having a qualified contractor make needed repairs.
    Photo 20   Master Bath


    45) The drain lever assembly is detached from the Main Bath tub. Recommend a qualified plumber attach the lever.
    Photo 25   Main Bath


    46)   One or more sink stopper mechanisms are missing, or need adjustment or repair. Stopper mechanisms should be installed where missing and/or repairs should be made so sink stoppers open and close easily.


    47)   Shower heads missing in both the Master and Main Bath.
    Photo 26   Main Bath


    48)   The main bath has a hole in the wall near the toilet.
    Photo 24   Main Bath


    49) Caulk is missing or deteriorated along the base of one or more bathtubs, where flooring meets the tub. It should be replaced where deteriorated and/or applied where missing to prevent water intrusion and damage to the floor structure.
    Photo 27   Main Bath


    50) Caulk is missing or deteriorated above one or more bathtubs, where the tub surround meets the tub. It should be replaced where deteriorated and/or applied where missing to prevent water intrusion and damage to the wall structure.
    Photo 19   Master Bath

     

    Return to table of contents


    51)   Based on the age of this structure and the appearance of existing smoke alarms, the alarms may be older than 10 years old. According to National Fire Protection Association, aging smoke alarms don't operate as efficiently and often are the source for nuisance alarms. Older smoke alarms are estimated to have a 30% probability of failure within the first 10 years. Newer smoke alarms do better, but should be replaced after 10 years. Unless you know that the smoke alarms are new, replacing them when moving into a new residence is also recommended by NFPA. For more information, visit this article: NFPA urges replacing home smoke alarms after 10 years.


    52)   An insufficient number of smoke alarms are installed. Additional smoke alarms should be installed as necessary so a functioning one exists in each hallway leading to bedrooms, and in each bedroom. For more information, visit http://www.cpsc.gov/cpscpub/pubs/5077.html


    53)   One or more air supply registers has a weak air flow, or no apparent flow, and may result in an inadequate air supply for heating/cooling. Recommend asking the property owner(s) about this. Adjustable damper(s) in ducts may exist and be reducing the flow. If dampers exist, then they should be opened to attempt to improve the air flow. If the property owner(s) are unaware of such dampers, or if adjusting dampers does not improve the air flow, then a qualified heating/cooling contractor should evaluate and repair or make modifications as necessary.


    54)   One or more electric receptacles appear to have no power. Recommend asking the property owner(s) about this. Switches may need to be operated to make some receptacles energized. If necessary, a qualified electrician should evaluate and make repairs as necessary.
    Photo 28   Living Room outlet


    55)   Seals between double-pane glass in one or more windows appear to have failed based on condensation or stains between the panes of glass. A qualified contractor should evaluate and replace glass where necessary.

    The client(s) should be aware that evidence of broken seals may be more or less visible from one day to the next depending on the temperature, humidity, sunlight, etc. Windows or glass doors other than those that the inspector identified may also have failed seals and need glass replaced too.
    Photo 23   Living Room window


    56)   Screen(s) in one or more windows are missing. The client(s) should ask the property owner(s) about this. Screens are often removed for window cleaning and they may be stored somewhere. If not, then recommend installing screens where missing.
    Photo 10   North side Screens missing


    57)   The main entrance deadbolt mechanism is inoperable. A qualified contractor should evaluate and repair as necessary.
    Photo 22   Front Door Deadbolt


    58)   Screen(s) in one or more windows are torn or have holes in them. Screens should be replaced where necessary.
    Photo 9   Screen Kitchen Window


    59)   Fixtures such as door stops, towel bars and/or toilet paper holders are missing in one or more areas. Recommend having a qualified contractor install fixtures where missing.


    60)   One or more light fixtures have missing bulbs and could not be fully evaluated. Bulbs may simply need to be installed, or repairs or replacement may be necessary.

     

    Photo 1   Back of house
    Photo 11   South side


     
    Westharbour Quality Inspections Inc. would like to thank you for providing us the opportunity of performing an inspection of you future home. We care about the quality of the inspection and report we provide. If you have any questions or concerns please do not hesitate to call us. We will be more than happy to assist you in anyway we can. If you are satisfied with the service we provided for you please keep us in mind if you or any of your associates have any future need of our services.