View as PDF


United Home Inspections


P.O. Box 393 
Kouts, IN 46347

 

Property Inspection Report
Client(s): John Buyer
Property address: 12345 Fake St.
Anytown, IN 46300
Inspection date: 01/01/2005
This report published on Tuesday, December 20, 2011 4:32:18 PM CST

View summary page

This report is the exclusive property of this inspection company and the client(s) listed in the report title. Use of this report by any unauthorized persons is prohibited.
This report is intended only as a guide to help the property owner / Buyer / Seller make their own evaluation of the overall condition of the property. This report is not intended to reflect the value of the property inspected, nor make representation as to the advisability of sale or purchase of the property inspected.

The report expresses the personal opinions of the inspector, based on his / her visual impressions of the conditions that existed at the time of the inspection only.

The inspection and report are not intended to be technically exhaustive, or to imply that every component was inspected, or that every possible defect was discovered. No disassembly of equipment, opening of walls, moving of furniture, appliances or stored items, or excavation was performed. All components and conditions which by the nature of their location are concealed, camouflaged, or difficult to inspect are excluded from this report.

Systems and conditions which are not within the scope of the property inspection include, but are not limited to: formaldehyde, lead paint, asbestos, toxic or flammable materials, and other environmental hazards; pest infestation, playground equipment, efficiency measurement of insulation or heating and cooling equipment; internal or underground drainage or plumbing; any systems which are shut down or otherwise secured; water wells (water quality and quantity); zoning ordinances; intercoms; security systems; heat sensors; cosmetics; building code conformity. Any general comments about these systems and conditions are informational only and do not represent and inspection.

This inspection report should not be construed as a compliance inspection of any government or non-governmental codes or regulations. The report is not intended to be a warranty or guarantee of the present or future adequacy or performance of the structure, its systems or their component parts. This report does not constitute any express or implied warranty of merchantability or fitness for use regarding the condition of the property, and it should not be relied upon as such. Any opinion expressed regarding adequacy, capacity, or expected life of components are general estimates based on information about similar components and occasional wide variations are to be expected between such estimates and actual experience.

United Home Inspections and its' inspectors have no interest, present or contemplated, in this property or its' improvement. United Home Inspections and its' inspectors have no involvement with tradespeople or benefits derived from any sales or improvements. To the best of our knowledge and belief, all statements and information in this report are true and correct.

This report shall supersede any written or verbal conversations, comments and or reports that were provided by United Home Inspections prior to providing this written report.

If repairs are made to a property based on the results of an inspection, the work should be performed by qualified contractors, not the seller. By qualified, we mean licensed, bonded, state-certified where applicable and with a reasonable amount of experience. Contractors providing repairs should provide legible documentation in the form of work orders and/or receipts. If repairs are made in this way, then there's generally no need for a follow-up inspection. Additionally, it may be better to negotiate a lower price on your home and have repairs made by contractors you choose rather than the seller making repairs as cheaply as possible."

It is in the clients best interest to follow up on any recommendations made by the Inspectors prior to making a finial purchase / sale decision. Purchasing a home for your family is a major financial decision, and it is not one to be made hastily or under rushed circumstances.

 
How to Read this Report
This report is organized by the property's functional areas.  Within each functional area, descriptive information is listed first and is shown in bold type.  Items of concern follow descriptive information.
Concerns are shown and sorted according to these types:
SafetyPoses a risk of injury or death 
Repair/ReplaceRecommend repairing or replacing 
Repair/MaintainRecommend repair and/or maintenance 
Minor DefectCorrection likely involves only a minor expense 
MaintainRecommend ongoing maintenance 
EvaluateRecommend evaluation by a specialist 
CommentFor your information 

Click here for a glossary of building construction terms.  Contact your inspector if there are terms that you do not understand, or visit the glossary of construction terms at http://www.reporthost.com/glossary.asp

Table of Contents
General Information
Grounds
Exterior / Foundation
Roof / Attic
Garage
Electric
Plumbing and Gas
Water Heater
Heating
Cooling
Fireplaces / Chimneys
Kitchen
Bathrooms / Laundry
Interior Rooms / Areas
Private Well

 
General Information Return to table of contents
Report number: 1502
Time started: 1:00 PM
Time finished: 4:15 PM
Inspector: Nathan Susdorf
Present during inspection: Client
Client present for discussion at end of inspection: Yes
Weather conditions: Cloudy
Temperature: 35 F
Ground condition: Damp
Inspection fee: Each inspection is priced based on square footage, age and location. Please contact us with this information for pricing details
Payment method: Check
Type of building: Single family
Buildings inspected: House with attached garage
Age of building(s): Built 2000
Source for building age: Property listing
Front of building faces: West
Main entrance faces: West
Occupied: Yes
1) Evidence of rodent infestation was found in the form of feces in one or more areas. For example, in the garage attic. Recommend consulting with the property owner about this. A qualified person should make repairs to seal openings in the structure, set traps, and clean rodent waste as necessary. Recommend following guidelines in these Center for Disease Control articles:
http://www.cdc.gov/rodents/prevent_rodents/seal_up.htm
http://www.cdc.gov/rodents/prevent_rodents/trap_up.htm
http://www.cdc.gov/rodents/prevent_rodents/clean_up.htm

2) Some wall and floor surfaces were obscured by furniture, stored items and couldn't be fully evaluated.
 
Grounds Return to table of contents
Limitations: The following items are not included in this inspection: swimming pools, spas, hot tubs, water features and related equipment; playground, recreation or leisure equipment; landscape lighting; areas below exterior structures with less than three feet of vertical clearance; irrigation systems; invisible fencing; sea walls, docks and boathouses. Any comments made regarding these items are as a courtesy only. Note that the inspector does not test or determine the adequacy of drainage systems for grounds, walkways, below-grade stairs and roof downspouts. The inspector does not provide an evaluation of geological conditions and/or site stability, compliance of pool or spa fencing with municipal requirements, or determination that deck, balcony and/or stair membranes are watertight.
Site profile: Level
Condition of driveway: Required repair, replacement and/or evaluation (see comments below)
Driveway material: Poured in place concrete
Condition of sidewalks and/or patios: Required repairs, replacement and/or evaluation (see comments below)
Sidewalk material: Poured in place concrete, Paving stones
Condition of exterior stairs: Appeared serviceable
Exterior stair material: Concrete
3) The driveway had significant cracks, settlement, heaving and/or deterioration in one or more areas. A qualified contractor should evaluate and repair or replace sections as necessary.

Photo 6  
Cracks in driveway
 

4) Patios had significant cracks, settlement, heaving and/or deterioration in one or more areas. A qualified contractor should evaluate and repair or replace sections as necessary.

Photo 8  
Patio is heaving
 

5) Vegetation such as trees, shrubs and/or vines was in contact with or less than one foot from the building exterior. Vegetation can serve as a conduit for wood destroying insects and may retain moisture against the exterior after it rains. Vegetation should be pruned and/or removed as necessary to maintain a one foot clearance between it and the building exterior.

Photo 36  
Trim all vegetation back at least a foot away from house
 

 
Exterior / Foundation Return to table of contents
Limitations: The following items are not included in this inspection: below-grade foundation walls and footings, or those obscured by vegetation or building components; exterior building surfaces or components obscured by vegetation, stored items or debris. Any comments made regarding these items are as a courtesy only. Some amount of cracking is normal in concrete slabs and foundation walls due to shrinkage and drying. Note that the inspector does not determination the adequacy of sump pumps, seismic reinforcement, nor determine if support posts, columns, beams, joists, studs, trusses, etc. are of adequate size, spanning or spacing.
Condition of wall covering: Appeared serviceable
Apparent wall structure: Wood frame
Wall covering: Vinyl
Condition of foundation and footings: Appeared serviceable
Foundation type: Finished basement
Foundation material: Poured in place concrete
Footing material: Not determined
Condition of floor substructure: Appeared serviceable
Pier or support post material: Steel
Beam material: Steel
Floor structure: Solid wood joists
Condition of the basement: Appeared serviceable
6) Some sections of siding and/or trim were damaged, loose, warped. A qualified person should evaluate and repair, replace or install siding or trim as necessary. * Warped near front door

Photo 9  
Damaged trim

Photo 15  
Popped out siding

Photo 16  
Popped out siding
 

7) One or more shutters were loose. This should be repaired by a qualified person.

Photo 37  
Loose shutter
 

8) Moss was growing on the siding. Water based solutions are available to kill this growth. A qualified person should apply as necessary.

Photo 11  
Moss on siding
 

9) A window well cover was missing. It should be reinstalled to prevent water and debris from entering window well.

Photo 12  
Window well cover missing
 

10) The exterior finish in some areas was failing. A qualified contractor should prep (pressure wash, scrape, sand, prime caulk, etc.) and repaint or restain areas as needed and as per standard building practices. * Around front door trim
11) Many sections of the floor substructure were not fully evaluated due lack of access from ducts or pipes drywall.
12) Minor cracks were found in one or more sections of slab floors.
 
Roof / Attic Return to table of contents
Limitations: The following items or areas are not included in this inspection: areas that could not be traversed or viewed clearly due to lack of access; areas and components obscured by insulation; solar roofing components; any comments made regarding these items are as a courtesy only. Note that the inspector does not determination if rafters, trusses, joists, beams, etc. are of adequate size, spanning or spacing. The inspector does not provide an estimate of remaining roof surface life, does not determine that the roof has absolutely no leaks at the time of the inspection, and does not determine that the roof won't leak in the future. Only active leaks and evidence of past leaks observed during the inspection are reported on as part of this inspection. To absolutely determine than no leaks exist, complete access to all roof structure areas must be available during a wide variety of weather conditions, including prolonged heavy rain, high wind from varying directions, heavy accumulations of snow and/or ice, and melting snow and ice.
Condition of roof structure: Appeared serviceable
Roof type: Gable
Age of roof surface(s): Original to house
Source for building age: Inspector's estimate
Roof inspection method: Viewed from ground with binoculars
Condition of shingle and/or shake roof surface materials: Appeared serviceable
Roof surface material: Asphalt or fiberglass composition shingles
Apparent number of layers of roof surface material: One
Condition of exposed flashings: Appeared serviceable
Condition of gutters, downspouts and extensions: Appeared serviceable
Gutter and downspout material: Metal
Gutter and downspout installation: Full
Condition of attic: Appeared serviceable
Attic inspection method: Viewed from hatch(es)
Roof structure type: Trusses
Ceiling insulation material: Fiberglass roll or batt, Mineral wool loose fill
Ceiling insulation depth: 10 inches
Ceiling insulation rating: Approx. 26-30 R
Roof ventilation: Appears serviceable
13) One or more composition shingles were missing. Leaks may occur as a result. A qualified contractor should evaluate and repair as necessary.

Photo 7  
Missing shingle
 

14) Extensions such as splash blocks or drain pipes for some downspouts were too close to house. Water may accumulate around the building foundation as a result. A qualified person should evaluate and repair, replace or install as necessary

Photo 17  
Gutter end too close to foundation
 

15) Moss was growing on the roof. As a result, shingles may lift or be damaged. Leaks may result and/or the roof surface may fail prematurely. This is a conducive condition for wood destroying insects and organisms. Efforts should be taken to kill the moss during its growing season (wet months). Typically zinc-based chemicals are used for this, and must be applied periodically. For information on various moss treatment products and their pros and cons, visit:
http://www.google.com/search?q=moss+on+roof

Photo 3  
Moss on roof
 

16) It is likely that there is inadequate insulation over the master bathroom. The ceiling temperature was only 59 degrees in this area. Other areas of the house had temperatures ranging from 69- 72 degrees. Not attic access was found in this area to determine the amount of insulation. Recommend further evaluation by a borescope or infrared camera.

Photo 29  
Bathroom ceiling cold
 

17) Because of the roof configuration, the inspector was unable to traverse the roof and wasn't able to fully evaluate the entire roof.
18) One or more downspouts terminated above roof surfaces rather than being routed to gutters below or to the ground level. This is very common, but it can reduce the life of roof surface materials below due to large amounts of water frequently flowing over the roof surface. Granules typically are washed off of composition shingles as a result, and leaks may occur. Recommend considering having a qualified contractor install extensions as necessary so downspouts don't terminate above roof surfaces.

Photo 1  
Gutter drains to roof
 

19) Some extra shingles were left on the roof when it was put on. These did not appear to be part of the roof surface at any point.

Photo 4  
Extra shingle on roof
 

 
Garage Return to table of contents
Limitations: The inspector does not determine the adequacy of firewall ratings. Requirements for ventilation in garages varies between municipalities.
Type: Attached
Condition of garage: Appeared serviceable
Type of garage: Solid core, Metal, With visible fire rating
Condition of garage vehicle door(s): Appeared serviceable
Garage vehicle door type: Sectional
Number of vehicle doors: 2
Condition of automatic opener(s): Appeared serviceable
Condition of garage floor: Appeared serviceable
Condition of garage interior: Appeared serviceable, drywalling not completed
20) Dried cement was found on the garage doors. This should be cleaned off by a qualified person.

Photo 5  
Cement on garage door
 

21) Items were being stored in the garage attic directly on the drywall. Recommend laying down plywood on ceiling joists if this is used for storage, to prevent damage to drywall.
 
Electric Return to table of contents
Limitations: The following items are not included in this inspection: generator systems, surge suppressors, inaccessible or concealed wiring; underground utilities and systems; low voltage lighting or lighting on timers or sensors. Any comments made regarding these items are as a courtesy only. Note that the inspector does not determine the adequacy of grounding or bonding, does not determine if this system has an adequate capacity for the client's specific needs, nor determine if this system has any reserve capacity for additions or expansion. The inspector does not operate circuit breakers as part of the inspection, install or change light bulbs, nor determine the operability of every wall switch.
Electric service condition: Appeared serviceable
Primary service type: Underground
Service voltage (volts): 120
Service amperage (amps): 200
Primary service overload protection type: Circuit breakers
Service entrance conductor material: Not determined
Main disconnect rating (amps): 200
System ground: Not determined
Condition of main service panel: Appeared serviceable
Location of main service panel #A: Basement
Location of main disconnect: Breaker at top of main service panel
Branch circuit wiring type: Non-metallic sheathed
Condition of branch circuit wiring: Serviceable
Solid strand aluminum branch circuit wiring present: None visible
Smoke detectors present: Yes
Carbon monoxide detectors present: None visible
Smoke detector power source: Not determined
22) One or more electric receptacles at the kitchen had no visible ground fault circuit interrupter (GFCI) protection. This is a safety hazard due to the risk of shock. Recommend having a qualified electrician evaluate to determine if GFCI protection exists, and if not, repair as necessary. For more information, visit:
http://www.mikeholt.com/documents/nec/pdf/GFCI_requirement_page2.pdf
* GFCI not required, but recommended in all kitchen receptacles

Photo 24  
GFCI recommended
 

23) Loose wires were exiting a receptacle box through the coverplate at one exterior location. This should be evaluated and repaired by a qualified person.

Photo 10  
Wires coming out behind coverplate
 

24) Permanent lighting was missing at one or more locations. For example master bedroom and over basement stairs. A qualified person should install lighting as necessary, and as per standard building practices.

Photo 30  
Missing permanent light fixture

Photo 38  
Light missing over stairs

25) This property had one or more fuel burning appliances and/or an attached garage, and no carbon monoxide detectors were visible. This is a safety hazard. Recommend installing one or more carbon monoxide detectors as necessary and as per the manufacturer's instructions. For more information, visit:
http://www.cpsc.gov/CPSCPUB/PREREL/prhtml05/05017.html

26) One or more junction box cover plates were missing. They are intended to contain fire and prevent electric shock from exposed wires. This is a safety hazard due to the risk of fire and shock. A qualified person should repair as necessary.

Photo 34  
Cover plate missing
 

27) Batteries in all the smoke alarms should be replaced after taking occupancy, and annually in the future. "Chirping" noises emitted from smoke alarms typically indicate that batteries need replacing. For more information, visit:
http://www.cpsc.gov/cpscpub/pubs/5077.html

28) One or more three-way light switches appear to be incorrectly wired, so the light(s) don't operate correctly. You should be able to turn the fixture on and off at both switches. A qualified electrician should evaluate and repair as necessary.

*Location: dining room

Photo 22  
3 way switches not working properly
 

29) Some bulbs in light fixtures were inoperable. As a result, some light fixtures couldn't be fully evaluated. Recommend replacing bulbs to fully evaluate fixtures where necessary.
30) The client should consult the current owner for the use of some light switches.
31) Additional photo

Photo 40  
Main electric shut-off breaker
 

 
Plumbing and Gas Return to table of contents
Limitations: The following items are not included in this inspection: private wells and sewage disposal systems; main, side and lateral sewer lines; gray water systems; pressure boosting systems; incinerating or composting toilets; fire suppression sprinkler systems; water softeners, conditioners or filtering systems; plumbing components concealed within the foundation or building structure, or in inaccessible areas such as below tubs; underground utilities and systems; overflow drains for tubs and sinks; backflow prevention devices. Any comments made regarding these items are as a courtesy only. Note that the inspector does not operate water supply or shut-off valves due to the possibility of valves leaking or breaking when operated. The inspector does not test for lead in the water supply, the water pipes or solder, does not determine if plumbing and fuel lines are adequately sized, and does not determining the existence or condition of underground or above-ground fuel tanks.
Condition of service and main line: Appeared serviceable
Water service: Private
Water pressure (psi): 45 PSI
Condition of supply lines: Appeared serviceable
Supply pipe material: Copper PEX
Condition of drain pipes: Appeared serviceable
Drain pipe material: Plastic
Condition of waste lines: Appeared serviceable
Waste pipe material: Plastic
Condition of fuel system: Appeared serviceable
Location of main fuel shut: At propane tank in back yard
32) Recommend having the septic tank inspected by a qualified specialist, and repaired if necessary. Recommend having the tank pumped if it was last pumped more than 3 years ago.
33) The sump pump was inoperable. Water was nearly to the top of the sump pit. This is a conducive condition for wood destroying insects and organisms due to the risk of water accumulation. The typical lifesan on a sump pump is 5-7 years. A qualified contractor should evaluate and repair as necessary.

Photo 35  
Sump pump would not operate during inspection, pit is over half full
 

34) A water softener system was installed on the premises. No evaluation of this system was performed during the inspection. The client should consult with the property owner on this system to determine its condition, required maintenance, age and expected remaining life, etc.
35) A sewage ejector pump was installed on the premises. These systems are typically sealed. Only a limited evaluation of this waste disposal system was performed during the inspection. This system has moving parts and is subject to clogging and/or damage from disposal of items such as disposable diapers and sanitary napkins. Recommend that this pump and related equipment (piping, valves, etc.) be evaluated by a qualified plumber and repaired if necessary every few years in the future, or as per the manufacturer's specifications. Typically these pumps have a lifespan of from seven to ten years.
36) Additional photo

Photo 13  
Main propane shut-off valve
 

 
Water Heater Return to table of contents
Limitations: The following items are not included in this inspection: solar water heating systems; circulation systems. Any comments made regarding these items are as a courtesy only. Note that the inspector does not provide an estimate of remaining life on water heaters, does not determine if water heaters are appropriately sized, or perform any evaluations that require a pilot light to be lit.
Condition of water heater: Appeared serviceable
Type: Tank
Estimated age: Manufactured- 1998
Energy source: Propane
Capacity (in gallons): 50
Manufacturer: A.O. Smith
Model: FSG50J01P040000
Location of water heater: Basement
Condition of burners: Appeared serviceable
Condition of venting system: Appeared serviceable
Condition of combustion air supply: Appeared serviceable
37) The estimated useful life for most water heaters is 8 to 12 years. This water heater appears to be at this age and/or its useful lifespan and may need replacing at any time. Recommend budgeting for a replacement in the near future.
 
Heating Return to table of contents
Limitations: The following items are not included in this inspection: humidifiers, dehumidifiers, electronic air filters; solar, coal or wood fired heat systems; thermostat or temperature control accuracy and timed functions; heating components concealed within the building structure or in inaccessible areas; underground utilities and systems; safety devices and controls (due to automatic operation). Any comments made regarding these items are as a courtesy only. Note that the inspector does not provide an estimate of remaining life on heating system components, does not determine if heating systems are appropriately sized, or perform any evaluations that require a pilot light to be lit. It is beyond the scope of this inspection to determine if furnace heat exchangers are intact and free of leaks.
Condition of heating system: Appeared serviceable Manufactured- December, 1997
Location of heating system: Basement
Heating type: Forced air
Fuel type: Propane gas
Approximate BTUs: 100,000
Manufacturer: Heil
Last service date: Not found
Condition of burners: Appeared serviceable
Condition of venting system: Appeared serviceable
Condition of combustion air supply: Appeared serviceable
Condition of distribution system: Appeared serviceable
Distribution system: Ducts and registers
Condition of controls: Appeared serviceable
Condition of air filters: Appeared serviceable
Location of air filters: At base of air handler Size, 16x25x1
38) The last service date of this system appeared to be more than one year ago, or the inspector was unable to determine the last service date. The client should ask the property owner when it was last serviced. If unable to determine the last service date, or if this system was serviced more than one year ago, a qualified contractor should service this system and make repairs if necessary. This servicing should be performed annually in the future.

Photo 39  
Clean furnace
 

39) The estimated useful life for most forced air furnaces is 15 to 20 years. This furnace appeared to be near this age and/or its useful lifespan and may need replacing or significant repairs at any time. Recommend budgeting for a replacement in the near future.
 
Cooling Return to table of contents
Limitations: The following items are not included in this inspection: humidifiers, dehumidifiers, electronic air filters; thermostat or temperature control accuracy and timed functions; cooling components concealed within the building structure or in inaccessible areas; underground utilities and systems; safety devices and controls (due to automatic operation). Any comments made regarding these items are as a courtesy only. Note that the inspector does not provide an estimate of remaining life on cooling system components, does not determine if cooling systems are appropriately sized, and does not test coolant pressure. Condensation pans and drain lines may clog or leak at any time and should be monitored while in operation in the future.
Condition of cooling system and/or heat pump: Not determined
Location: South side of house
Type: Split system
Estimated age: Manufactured- August, 1998
Approximate tonnage: 3
Manufacturer: Heil
40) The last service date of this system appeared to be more than one year ago, or the inspector was unable to determine the last service date. The client should ask the property owner when it was last serviced. If unable to determine the last service date, or if this system was serviced more than one year ago, a qualified contractor should service this system and make repairs if necessary. This servicing should be performed annually in the future.
41) The outdoor air temperature was below 60 degrees Fahrenheit during the inspection. The compressor can be damaged if it is operated at temperatures under 60 F. Because of this, the inspector was unable to operate and fully evaluate the cooling system.

Photo 14  
A/C could not be tested
 

42) The estimated useful life for most cooling systems and heat pumps is 10 to 15 years. This system appears to be at this age and/or its useful lifespan and may need replacing or significant repairs at any time. Recommend budgeting for a replacement in the near future.
 
Fireplaces / Chimneys Return to table of contents
Limitations: The following items are not included in this inspection: coal stoves, gas logs, chimney flues (except where visible). Any comments made regarding these items are as a courtesy only. Note that the inspector does not determine the adequacy of drafting or sizing in fireplace and stove flues, nor determine if prefabricated or zero clearance fireplaces are installed in accordance with the manufacturer's specifications. The inspector does not perform any evaluations that require a pilot light to be lit.
Location #A: Metal furnace/water heater chimney
Location #B: Fireplace
Fireplace type: Prefabricated
Fuel type: Propane
Condition of chimneys: Required repair, replacement and/or evaluation (see comments below)
Chimney type: Metal
43) The metal flue pipe at location #A was too close to combustibles. This is a fire hazard. A qualified contractor should evaluate and make repairs or modifications as necessary so minimum clearances to combustibles are maintained around all chimney and flue pipes as per the manufacturer's specifications.
* Close to plastic near furnace, wrapped in insulation in attic

Photo 33  
Chimney too close to combustibles (this is above furnace)
 

44) The gas fireplace at location #B was not fully evaluated because inspector was unable to light. Recommend consulting current owner for use and condition.
 
Kitchen Return to table of contents
Limitations: The following items are not included in this inspection: free-standing or portable appliances such as dishwashers, trash compactors, refrigerators, freezers, ice makers; specialty appliances such as hot water dispensers, water filters and trash compactors; appliance timers, clocks, cook functions, self and/or continuous cleaning operations, thermostat or temperature control accuracy, and lights. Any comments made regarding these items are as a courtesy only. Note that the inspector does not provide an estimate of the remaining life of appliances, and does not determine the adequacy of operation of appliances such as dishwashers, garbage disposals, trash compactors, ovens, broilers, etc.
Condition of counters: Appeared serviceable
Condition of cabinets: Appeared serviceable
Condition of sinks and related plumbing: Appeared serviceable
Condition of garbage disposal: Appeared serviceable
Condition of dishwasher: Appeared serviceable
Condition of range, cooktop: Appeared serviceable
Range, cooktop type: Propane
Condition of refrigerator: Appeared serviceable
45) The cabinet door and face was not securely attached at one or more areas. A qualified person should repair as necessary.

Photo 25  
Loose cabinet face
 

 
Bathrooms / Laundry Return to table of contents
Limitations: The following items are not included in this inspection: overflow drains for tubs and sinks; bidets, heated towel racks, saunas, steam generators, clothes washers, clothes dryers. Any comments made regarding these items are as a courtesy only. Note that the inspector does not determine the adequacy of washing machine drain lines, washing machine catch pan drain lines, or clothes dryer exhaust ducts. The inspector does not operate water supply or shut-off valves for sinks, toilets, bidets, clothes washers, etc. due to the possibility of valves leaking or breaking when operated. The inspector does not determine if shower pans or tub and shower enclosures are water tight, or determine the completeness or operability of any gas piping to laundry appliances.
Location #A: Main level bathroom
Location #B: Master bathroom
Location #C: Upstairs bathroom
Location #D: Basement bathroom
Location #E: Laundry area
Condition of counters: Appeared serviceable
Condition of cabinets: Appeared serviceable
Condition of sinks and related plumbing: Appeared serviceable
Condition of toilets: Appeared serviceable
Condition of bathtubs and related plumbing: Appeared serviceable
Condition of shower(s) and related plumbing: Appeared serviceable
Condition of ventilation systems: Required repair, replacement and/or evaluation (see comments below)
Condition of laundry facilities: Appeared serviceable
Gas supply for laundry equipment present: Yes
240 volt receptacle for laundry equipment present: Not determined
46) The sink drain stopper mechanism at location #A was inoperable. A qualified person should repair or replace as necessary.

Photo 23  
Stopper not functioning
 

47) The exhaust fan at location #D was inoperable. Moisture may accumulate as a result. A qualified person should evaluate and repair or replace as necessary.
48) A leak was found at the bathtub supply valves at location #B. A qualified plumber should evaluate and repair as necessary.

Photo 27  
Leaking faucet handle
 

49) One or more clothes washer supply hoses were rubber. Significant water damage may occur if these hoses fail. Recommend replacing hoses with braided, stainless steel hoses. Recommend replacement every 5 years.
50) The bathtub at location #B needs to be recaulked around the edge. This should be done by a qualified person.

Photo 28  
Recaulk around tub
 

 
Interior Rooms / Areas Return to table of contents
Limitations: The following items are not included in this inspection: security, intercom and sound systems; communications wiring; central vacuum systems; elevators and stair lifts; sources of obnoxious odors; cosmetic deficiencies due to normal wear and tear in wall, floor and ceiling surfaces and coverings, or in equipment; deficiencies relating to interior decorating; low voltage and gas lighting systems. Any comments made regarding these items are as a courtesy only. Note that the inspector does not evaluate any areas or items which require moving stored items, furnishings, debris, equipment, floor coverings, insulation or similar materials. The inspector does not test for asbestos, lead, radon, mold, hazardous waste, urea formaldehyde urethane, or any other toxic substance. Some items such as window operability are tested on a sampled basis. The client should be aware that paint may obscure wall and ceiling defects, floor coverings may obscure floor defects, and furnishings may obscure wall, floor and floor covering defects. If furnishings were present during the inspection, recommend a full evaluation of walls, floors and ceilings that were previously obscured when possible. Determining the cause of odors is not within the scope of this inspection.
Exterior door material: Metal, Sliding glass
Condition of exterior entry doors: Required repair, replacement and/or evaluation (see comments below)
Condition of interior doors: Appeared serviceable
Type of windows: Wood, Multi, Casement, Double hung, Fixed
Condition of windows: Appeared serviceable
Wall type or covering: Drywall
Condition of walls: Appeared serviceable
Ceiling type or covering: Drywall
Condition of ceilings: Appeared serviceable
Flooring type or covering: Carpet, Linoleum, Tile
Condition of flooring: Appeared serviceable
51) Handrails at one or more flights of stairs were wobbly. This is a safety hazard. Standard building practices require that handrails be:

  • Installed at stairs with four or more risers
  • Sized and shaped so your hand can encircle them
  • Permanently and securely attached, and able to withstand a 200 pound force in any direction at any point
  • Continuous and extend for the entire flight of the stairs
  • Located between 30 and 38 inches above the leading edge of the stair treads

    A qualified person should repair, replace or install as necessary and as per standard building practices.

    Photo 31  
    Wobbly handrail
     

    52) Some sections of flooring had minor deterioration or damage. For example, broken tile. A qualified person should repair as necessary.

    Photo 20  
    Cracked tile

    Photo 21  
    Cracked tile

    53) The rear sliding screen door falls off when opened, and does not close properly. A qualified person should make repairs as necessary.

    Photo 26  
    Screen door falls off, along with trim piece
     

    54) Minor cracks were found in ceilings in one or more areas. They do not appear to be a structural concern, but the client may wish to repair these for aesthetic reasons.
    55) Blinds at one or more windows were damaged.

    Photo 32  
    Broken blinds
     

     
    Private Well Return to table of contents
    Limitations: The inspector does not test private well water for contamination or pollutants, determine if the supply and/or flow are adequate, or provide an estimate for remaining life of well pumps, pressure tanks or equipment. Only visible components are evaluated. The client should have qualified lab test the well water for bacterial contaminants. A qualified well specialist should evaluate the well and perform a yield test.
    Condition of private water supply: Appeared serviceable
    Type of well: Drilled
    Location of well: North side of yard
    Pressure test results: 45 PSI
    Flow test results: 6.5 Gallons per minute
    56) Recommend having the well water tested for coliform bacteria, nitrates, and anything else of local concern, by a qualified lab. For more information, visit http://www.wellowner.org
    57) Additional photos

    Photo 18  
    Water pressure 45 PSI

    Photo 19  
    Water flow 6.5 GPM

     
    *****This concludes the home inspection report*****

    Thank you for choosing United Home Inspections. Please contact us if you have any questions.

    Please read the following about home inspections:

    Please understand that we give our best effort in every inspection. There may come a time when you discover something wrong with the house you purchased, and you may be upset or disappointed with your home inspection. There are some things we’d like you to keep in mind.

    -Intermittent Or Concealed Problems
    Some problems can only be discovered by living in a house. They cannot be discovered during the few hours of a home inspection. For example, some shower stalls leak when people are in the shower, but do not leak when you simply turn on the tap. Some roofs and basements only leak when specific conditions exist. Some problems will only be discovered when carpets are lifted, furniture is moved or finishes are removed.

    -No Clues
    These problems may have existed at the time of the inspection, but there were no clues as to their existence. Our inspections are based on the past performance of the house. If there are no clues of a past problem, it is unfair to assume we should foresee a future problem.

    -We Always Miss Some Minor Things
    Some say we are inconsistent because our reports identify some minor problems, but not others. The minor problems that are identified were discovered while looking for more significant problems. We note them simply as a courtesy. The intent of the inspection is not to find the $10 problems; it is to find the $1,000 problems. These are the things that affect people’s decisions to purchase.

    -Contractor’s Advice
    A common source of dissatisfaction with home inspectors comes from comments made by contractors. Contractor’s opinions often differ from ours. Don’t be surprised when three roofers all say the roof needs replacement, when we said that the roof would last a few more years with some minor repairs.

    -Last Man In Theory
    While our advice represents the most prudent thing to do, many contractors are reluctant to undertake these repairs. This is because of the last man in theory. The contractor fears that if he is the last person to work on the roof, he will get blamed if the roof leaks, regardless of whether or not the roof leak is his fault. Consequently, he won’t want to do a minor repair with high liability, when he could re-roof the entire house for more money and reduce the likelihood of a callback. This is understandable.

    -Most Recent Advice Is Best
    There is more to the last man in theory. It suggests that it is human nature for homeowners to believe the last bit of expert advice they receive, even if it is contrary to previous advice. As home inspectors, we unfortunately find ourselves in the position of first man in and consequently it is our advice that is often disbelieved.

    -Why Didn’t We See It?
    Contractors often say, I can’t believe you had this house inspected, and the inspector didn’t find this problem. There are several reasons for these apparent oversights:

    Most Contractors Have No Clue What’s Inside or Outside The Scope Of A Standard Home Inspection: All of our inspections are conducted in accordancewith the Standards of Practice of The National Association of Home Inspectors.The Standards of Practice specifically state what’s included and excluded from the standard home inspection.

    Most contractors have no clue this document exists and many of them have a tendency to “blame the Home Inspector” for any issue found, regardless ofwhether the issue is within the “scope” of the standard home inspection.

    -Conditions During The Inspection
    It is difficult for homeowners to remember the circumstances in the house at the time of the inspection. Homeowners seldom remember that it was snowing, there was storage everywhere or that the furnace could not be turned on because the air conditioning was operating, etc. It’s impossible for contractors to know what the circumstances were when the inspection was performed.

    -The Wisdom Of Hindsight
    When the problem manifests itself, it is very easy to have 20/20 hindsight. Anybody can say that the basement is wet when there is 2 feet of water on the floor. Predicting the problem is a different story.

    -A Long Look
    If we spent half an hour under the kitchen sink or 45 minutes disassembling the furnace, we’d find more problems, too. Unfortunately, the inspection would take several days and would cost considerably more.

    -We’re Generalists
    We are generalists; we are not specialists. The heating contractor may indeed have more heating expertise than we do. This is because we are expected to have heating expertise and plumbing expertise, structural expertise, electrical expertise, etc.

    -An Invasive Look
    Problems often become apparent when carpets or plaster are
    removed, when fixtures or cabinets are pulled out, and so on. A home inspection is a visual examination. We don’t perform invasive or destructive tests.

    -Not Insurance
    In conclusion, a home inspection is designed to better your odds of not purchasing a “money pit”. It is not designed to eliminate all risk. For that reason, a home inspection should not be considered an insurance policy. The premium that an insurance company would have to charge for a policy with no deductible, no limit and an indefinite policy period would be considerably more than the fee we charge. It would also not include the value added by the inspection.

    Please call us at (219)263-9282 if you have any questions.