Top To Bottom Real Estate Inspections

Website: http://www.ttbrei.com
Email: ballen@cablene.com
Phone: (402) 910-7424
3330 87th St 
Columbus NE 68601-8066
Inspector: Bill Allen
InterNACHI Member ID NACHI10091101

 

Property Inspection Report
Client(s): Sample Report 1
Property address: Columbus, NE 68601
Inspection date: 6/1/2011
This report published on Tuesday, August 09, 2011 10:49:44 AM CDT

View summary page

This report is the exclusive property of this inspection company and the client(s) listed in the report title. Use of this report by any unauthorized persons is prohibited.

 
How to Read this Report
This report is organized by the property's functional areas.  Within each functional area, descriptive information is listed first and is shown in bold type.  Items of concern follow descriptive information.
Concerns are shown and sorted according to these types:
SafetyPoses a risk of injury or death 
Major DefectCorrection likely involves a significant expense 
Repair/ReplaceRecommend repairing or replacing 
Repair/MaintainRecommend repair and/or maintenance 
Minor DefectCorrection likely involves only a minor expense 
MaintainRecommend ongoing maintenance 
EvaluateRecommend evaluation by a specialist 
MonitorRecommend monitoring in the future 
ServiceableItem or component is in servicable condition 
CommentFor your information 

Click here for a glossary of building construction terms.  Contact your inspector if there are terms that you do not understand, or visit the glossary of construction terms at http://www.reporthost.com/glossary.asp

Table of Contents
General Information
Grounds
Exterior / Foundation
Roof / Attic
Garage / Carport
Water Heater
Heating
Cooling / Heat Pump
Fireplaces / Stoves / Chimneys
Kitchen
Bathrooms / Laundry / Sinks
Interior Rooms / Areas
Private Well
Electric
Plumbing / Fuel Systems
 
General Information Return to table of contents
Report number: Sample Report 1
Time started: 5:15 pm
Time finished: 7:00 pm
Inspector: Bill Allen
Present during inspection: Client, Property owner
Client present for discussion at end of inspection: Yes
Temperature: Warm
Ground condition: Dry
Payment method: Check
Type of building: Single family
Buildings inspected: House with attached garage
Number of residential units inspected: one
Age of building(s): 37 years
Source for building age: Property owner
Front of building faces: West
Main entrance faces: West
Occupied: Yes
Property owner's name:
Time started: 5:15 PM
Time finished: 7:00 pm
Inspector: Bill Allen
Present during inspection: Client, Property owner
Client present for discussion at end of inspection: Yes
Weather conditions: Clear
Temperature: Warm
Ground condition: Damp
Payment method: Check
Type of building: Single family
Buildings inspected: Home and attached garage
Number of residential units inspected: 1
Age of building(s): 37 years old
Source for building age: Property owner
Front of building faces: West
Main entrance faces: West
Occupied: Yes, Furniture or stored items were present
1) Structures built prior to 1980 may contain lead-based paint and/or asbestos in various building materials such as insulation, siding, and/or floor and ceiling tiles. Both lead and asbestos are known health hazards. Evaluating for the presence of lead and/or asbestos is not included in this inspection. The client should consult with specialists as necessary, such as industrial hygienists, professional labs and/or abatement contractors for this type of evaluation. For information on lead, asbestos and other hazardous materials in homes, visit:
http://www.epa.gov
http://www.cpsc.gov
http://www.cdc.gov

2) Structures built prior to 1980 may contain lead-based paint and/or asbestos in various building materials such as insulation, siding, and/or floor and ceiling tiles. Both lead and asbestos are known health hazards. Evaluating for the presence of lead and/or asbestos is not included in this inspection. The client should consult with specialists as necessary, such as industrial hygienists, professional labs and/or abatement contractors for this type of evaluation. For information on lead, asbestos and other hazardous materials in homes, visit:
http://www.epa.gov
http://www.cpsc.gov
http://www.cdc.gov

3) Some wall and floor surfaces were obscured by furniture and couldn't be fully evaluated. Home is occupied and all furnishings were in place.
4) The client should be aware that prior to 1976, factory built homes in America were built only according to voluntary standards. Because this building was built prior to 1976, it may be significantly substandard in safety, efficiency, quality, durability, etc. Factory built homes since 1976 have been required to comply with federal construction and safety standards (the HUD Code). This code is administered by the U.S. Department of Housing and Urban Development (HUD), and standardizes design, construction, energy efficiency, fire resistance, transportability, strength, and durability. It also mandates performance standards for the electrical, plumbing, air conditioning, thermal, and heating systems.
 
Grounds Return to table of contents
Limitations: The following items are not included in this inspection: swimming pools, spas, hot tubs, water features and related equipment; playground, recreation or leisure equipment; landscape lighting; areas below exterior structures with less than three feet of vertical clearance; irrigation systems; invisible fencing; sea walls, docks and boathouses. Any comments made regarding these items are as a courtesy only. Note that the inspector does not test or determine the adequacy of drainage systems for grounds, walkways, below-grade stairs and roof downspouts. The inspector does not provide an evaluation of geological conditions and/or site stability, compliance of pool or spa fencing with municipal requirements, or determination that deck, balcony and/or stair membranes are watertight.
Condition of fences and gates: Required repairs, replacement and/or evaluation (see comments below)There were some of the top rals of chain limk fence that were bent as well as one upright post that was bent.
Fence and gate material: Chain link
Site profile: Minor slope
Driveway material: Poured in place concrete
Condition of sidewalks and/or patios: Appeared serviceable
Deck, patio, porch cover material and type: Open
Condition of decks, porches and/or balconies: Appeared serviceable
Deck, porch and/or balcony material: Wood, Concrete
Condition of exterior stairs: Appeared serviceable
5) One or more large trees on the property may fall on the building, and are a potential safety hazard. Recommend consulting with a qualified arborist to determine if tree(s) need to be removed and/or pruned. The tree in the front yard could fall toward the house and possibly hit the home in the event of a strong wind from the west. The tree was trimmed and there was no overhang above the house.

Photo 1  

Photo 2  
Well less than 30 feet from house.

6) Fences were damaged or deteriorated in some areas. A qualified person should repair or replace sections as necessary. There were some top rials of fence that were bent as well as one upright post that was bent

Photo 22  

Photo 23  

7) Recommend grading soil so it slopes down and away from the structure with a slope of at least 5% (10% or better is optimal) for at least 6 feet. The slope is close to the recommended 5% to 10%. Recommendation is to watch for water accumulation next to the house after heavy rains to verify that no water has accumulates next to the foundation and if water accumulates grade slope away so water does not acccumulate.

Photo 5  

Photo 25  

8) Decking boards were spaced approximately 3/8 inch apart. If organic debris (leaves, fir needles, etc.) accumulates on the wood deck; this is a conducive condition for wood destroying organisms. Debris should be cleaned as necessary to prevent accumulation and resultant rot. If or when the deck boards are replaced, recommend spacing boards so they're at least 3/8 inch apart to allow debris to fall through the cracks rather than accumulate in them.

Photo 11  
 

9) Minor cracks, settlement, heaving and/or deterioration were found in the driveway. However they don't appear to be a structural concern and no trip hazards were found. No immediate action is recommended, but the client may wish to have repairs made or have cracked sections replaced for aesthetic reasons.

Photo 1  
 

10) Areas of the porch substructure were inaccessible due to lack of access. These areas couldn't be evaluated and are excluded from the inspection. The front wood porch deck substructure was not inspected. The top decking material was solid and well maintained.
 
Exterior / Foundation Return to table of contents
Limitations: The following items are not included in this inspection: below-grade foundation walls and footings, or those obscured by vegetation or building components; exterior building surfaces or components obscured by vegetation, stored items or debris. Any comments made regarding these items are as a courtesy only. Some amount of cracking is normal in concrete slabs and foundation walls due to shrinkage and drying. Note that the inspector does not determination the adequacy of sump pumps, seismic reinforcement, nor determine if support posts, columns, beams, joists, studs, trusses, etc. are of adequate size, spanning or spacing.
Condition of wall covering: Appeared serviceable, there were some areas that sofit was a loose and should be evaluated.
Apparent wall structure: Wood frame
Wall covering: Vinyl
Condition of foundation and footings: Not determined
Foundation type: Finished basement
Foundation material: Not determined
Footing material: Not determined
Condition of floor substructure: Appeared serviceable
Floor structure: Pored in place concrete
Condition of the basement: Appeared serviceable
11) Many basement sections were not evaluated due to lack of access from the following conditions: carpet and couldn't be fully evaluated. Basement was fully finished, the only floor in the basement not covered was in the furnace/utility room which housed the water conditioner, electric furnace/ac unit, water pressure tank and the reverse osmoses water treatment system.
12) All foundation and/or footings sections were obscured by being below grade, fully furnished basement and couldn't be fully evaluated.
13) All sections of the floor substructure were not fully evaluated due lack of access from basement. The basement ceiling is finished.
 
Roof / Attic Return to table of contents
Limitations: The following items or areas are not included in this inspection: areas that could not be traversed or viewed clearly due to lack of access; areas and components obscured by insulation; solar roofing components; any comments made regarding these items are as a courtesy only. Note that the inspector does not determination if rafters, trusses, joists, beams, etc. are of adequate size, spanning or spacing. The inspector does not provide an estimate of remaining roof surface life, does not determine that the roof has absolutely no leaks at the time of the inspection, and does not determine that the roof won't leak in the future. Only active leaks and evidence of past leaks observed during the inspection are reported on as part of this inspection. To absolutely determine than no leaks exist, complete access to all roof structure areas must be available during a wide variety of weather conditions, including prolonged heavy rain, high wind from varying directions, heavy accumulations of snow and/or ice, and melting snow and ice.
Condition of roof structure: Appeared serviceable
Roof type: Gable
Age of roof surface(s): New roof installed in 2009 (information provided by owner)
Source for building age: Property owner
Roof inspection method: Traversed, Viewed from eaves on ladder
Condition of shingle and/or shake roof surface materials: Appeared serviceable
Roof surface material: Asphalt or fiberglass composition shingles
Apparent number of layers of roof surface material: One
Condition of exposed flashings: Appeared serviceable
Condition of gutters, downspouts and extensions: Appeared serviceable
Gutter and downspout material: Metal
Gutter and downspout installation: Full
Condition of attic: Appeared serviceable
Attic inspection method: Viewed from hatch(es), Partially traversed
Roof structure type: Trusses
Ceiling structure: Trusses
Ceiling insulation material: Cellulose loose fill
Ceiling insulation depth: 8 to 10 inches
Vapor retarder: None visible
Roof ventilation: Appears serviceable
14) The attic access hatch over the attached garage was not fire-rated. Wall and ceiling surfaces in an attached garage should be fire rated for one hour to prevent or slow the spread of fire from the garage to interior living spaces. A hatch should be installed with a material that has a one hour fire rating, such as 5/8 inch Type X sheetrock.
15) The ceiling insulation in the garage areas of the attic was missing. This may result in increased heating or cooling costs due to decreased energy efficiency. A qualified person should repair, replace or install insulation as necessary. For more information, visit:
http://www.eere.energy.gov/consumer/tips/insulation.html There was no insulation in the attic above the garage.

16) Debris had accumulated in one or more gutters. This is a conducive condition for wood destroying insects since gutters may overflow and cause water to come in contact with the building exterior or make water accumulate around the foundation. Gutters should be cleaned now and as necessary in the future.

Photo 10  

Photo 13  

Photo 15  
Build up of dirt in bottom of gutter 1/8 to 1/4 deep, should be cleaned on an annual basis.
 

17) One or more downspouts terminated above roof surfaces rather than being routed to gutters below or to the ground level. This is very common, but it can reduce the life of roof surface materials below due to large amounts of water frequently flowing over the roof surface. Granules typically are washed off of composition shingles as a result, and leaks may occur. Recommend considering having a qualified contractor install extensions as necessary so downspouts don't terminate above roof surfaces.

Photo 21  
Gutter empties on roof surface, this will acclerate wear on area water runs on the lower roof surface.
 

18) Some attic and roof structure sections were not evaluated due to lack of access from the following conditions: hatch inaccessible, stored items. Very difficult access to attic over living area because of small hatch opening and access. Materials in the garage below the living area access hatch made access difficult. Attic above garage was inspected but had very low headroom. The ceiling above garage was finished with plywood but there was no insulation above the garage area.

Photo 8  
Very difficult yo access attic from closet. would have to remove shelves and contents.

Photo 18  
Approximately 8 to 10 inches of blown in insulation in attic over living area.

Photo 19  

Photo 20  
 
Garage / Carport Return to table of contents
Limitations: The inspector does not determine the adequacy of firewall ratings. Requirements for ventilation in garages varies between municipalities.
Type: Attached
Condition of detached garage or carport structure: Appeared serviceable
Condition of garage vehicle door(s): Appeared serviceable
Garage vehicle door type: Sectional
Number of vehicle doors: 1
Condition of automatic opener(s): Appeared serviceable, operated and checked safety eyes, safety eyes were operational
Condition of garage floor: Appeared serviceable
Condition of garage interior: Appeared serviceable
Garage ventilation: Should be evaluated and added if found inadequate
19) One or more openings were found in the attached garage ceilings. These surfaces are intended to prevent vehicle fumes and/or fire from entering or spreading to living spaces or unfinished areas adjacent to living spaces. A qualified contractor should evaluate and make repairs as necessary so the attached garage wall and ceiling surfaces that adjoin living spaces are tightly sealed and fire rated as per standard building practices.

Photo 16  
 

20) The self-closing device on the garage-dwelling door is missing. This door is intended to prevent vehicle fumes from entering living spaces and to slow the spread of fire from the garage to living spaces. A qualified person should evaluate and make repairs as necessary.
21) No venting or only minimal venting was found in the garage. This may result in poor indoor air quality or high temperatures inside. Recommend that a qualified person install vents as per standard building practices. There are attic vents but no venting in the garage area.
22) Some floor areas were obscured by stored items and couldn't be evaluated. These areas are excluded from the inspection.
23) Minor cracks, heaving and/or settlement were found in one or more sections of slab floors.
 
Water Heater Return to table of contents
Limitations: The following items are not included in this inspection: solar water heating systems; circulation systems. Any comments made regarding these items are as a courtesy only. Note that the inspector does not provide an estimate of remaining life on water heaters, does not determine if water heaters are appropriately sized, or perform any evaluations that require a pilot light to be lit.
Condition of water heater: Appeared serviceable
Type: Tank
Energy source: Electricity
Capacity (in gallons): 40
Location of water heater: Basement utility room
24) This water heater was not fully evaluated because the water heater is leased from Loup Public Power and they are responsible for any repairs or replacement as needed and LPPD whould inspect at users request . Recommend that a full evaluation be made LPPD if any issues are found with water heater. Note that as per the standards of practice for NACHI (http://www.nachi.org) and ASHI (www.ashi.org), the inspector is not required to operate shut-off valves, pilot lights or overcurrent protection devices, or any controls other than "normal controls".
 
Heating Return to table of contents
Limitations: The following items are not included in this inspection: humidifiers, dehumidifiers, electronic air filters; solar, coal or wood fired heat systems; thermostat or temperature control accuracy and timed functions; heating components concealed within the building structure or in inaccessible areas; underground utilities and systems; safety devices and controls (due to automatic operation). Any comments made regarding these items are as a courtesy only. Note that the inspector does not provide an estimate of remaining life on heating system components, does not determine if heating systems are appropriately sized, or perform any evaluations that require a pilot light to be lit. It is beyond the scope of this inspection to determine if furnace heat exchangers are intact and free of leaks.
Condition of heating system: Appeared serviceable
Location of heating system: Mechanical room, Basement
Heating type: Forced air, Heat pump. Resistance heat
Fuel type: Electric
Source for last service date: Property owner
Condition of distribution system: Appeared serviceable
Distribution system: Ducts and registers
Condition of air filters: Appeared serviceable and were clean
Location of air filters: above blower motor on air handler
25) The estimated useful life for most forced air furnaces is 15 to 20 years. This furnace appeared to be near this age and/or its useful lifespan and may need replacing or significant repairs at any time. Recommend budgeting for a replacement in the near future.
26) The last service date of this system appeared to be more than two years ago, or the inspector was unable to determine the last service date. The client should ask the property owner when it was last serviced. If unable to determine the last service date, or if this system was serviced more than two years ago, a qualified heating and cooling contractor should inspect, clean, and service this system, and make repairs if necessary. This servicing should be performed every few years in the future, or as per the contractor's recommendations.
27) One or more air filters were inspected and found clean . A qualified person should change filter(s) as necessary. Filters should be checked monthly and maintained as necessary in the future. Air filter when checked was clean. Owner advised that the filter was of a special size and may need to be ordered from local supplier.
28) The opening for the air filter makes it difficult to replace filter for a new one. Care needs to be taken when removing filter so it does not become lodged in opening. A tool may need to be fabricated to assist with filter removal.
29) This heating system used electric heat. It is a specialty system, and only a limited evaluation was performed during the inspection. Recommend a full evaluation by a qualified specialist.
 
Cooling / Heat Pump Return to table of contents
Limitations: The following items are not included in this inspection: humidifiers, dehumidifiers, electronic air filters; thermostat or temperature control accuracy and timed functions; cooling components concealed within the building structure or in inaccessible areas; underground utilities and systems; safety devices and controls (due to automatic operation). Any comments made regarding these items are as a courtesy only. Note that the inspector does not provide an estimate of remaining life on cooling system components, does not determine if cooling systems are appropriately sized, and does not test coolant pressure. Condensation pans and drain lines may clog or leak at any time and should be monitored while in operation in the future.
Condition of cooling system and/or heat pump: Appeared serviceable
Type: Heat pump
Approximate tonnage: 3
Condition of distribution system: Appeared serviceable
Condition of air filters: Appeared serviceable
Location of air filters: At base of air handler
30) The last service date of this system appeared to be more than one year ago, or the inspector was unable to determine the last service date. The client should ask the property owner when it was last serviced. If unable to determine the last service date, or if this system was serviced more than one year ago, a qualified contractor should service this system and make repairs if necessary. This servicing should be performed annually in the future.
 
Fireplaces / Stoves / Chimneys Return to table of contents
Limitations: The following items are not included in this inspection: coal stoves, gas logs, chimney flues (except where visible). Any comments made regarding these items are as a courtesy only. Note that the inspector does not determine the adequacy of drafting or sizing in fireplace and stove flues, nor determine if prefabricated or zero clearance fireplaces are installed in accordance with the manufacturer's specifications. The inspector does not perform any evaluations that require a pilot light to be lit.
Condition of fireplaces, stoves: There were no fireplaces or stoves in the home at time of inspection. There is a chimney installed and should be inspected before installing a fireplace or solid fuel burning stove.
Condition of chimneys: Not determined
Chimney type: Metal
31) Recommend that all wood burning appliances (fireplaces and stoves) and chimneys be evaluated by a specialist who is a a member of the Chimney Safety Institute of America or National Chimney Sweep Guild, and cleaned and/or repaired as necessary.

This should be done before installing any wood burning appliances,
 
Kitchen Return to table of contents
Limitations: The following items are not included in this inspection: free-standing or portable appliances such as dishwashers, trash compactors, refrigerators, freezers, ice makers; specialty appliances such as hot water dispensers, water filters and trash compactors; appliance timers, clocks, cook functions, self and/or continuous cleaning operations, thermostat or temperature control accuracy, and lights. Any comments made regarding these items are as a courtesy only. Note that the inspector does not provide an estimate of the remaining life of appliances, and does not determine the adequacy of operation of appliances such as dishwashers, garbage disposals, trash compactors, ovens, broilers, etc.
Condition of counters: Appeared serviceable
Condition of cabinets: Appeared serviceable
Condition of sinks and related plumbing: Appeared serviceable
Condition of garbage disposal: Appeared serviceable
Condition of dishwasher: Appeared serviceable
Condition of range, cooktop: Appeared serviceable
Range, cooktop type: Electric
Condition of refrigerator: Appeared serviceable
32) No exhaust hood or fan was installed over the cook top. Ventilation and/or lighting may be inadequate and moisture may accumulate indoors. Recommend having a qualified contractor install a vented and lighted range hood, with the exhaust fan configured so as to vent outdoors.
 
Bathrooms / Laundry / Sinks Return to table of contents
Limitations: The following items are not included in this inspection: overflow drains for tubs and sinks; bidets, heated towel racks, saunas, steam generators, clothes washers, clothes dryers. Any comments made regarding these items are as a courtesy only. Note that the inspector does not determine the adequacy of washing machine drain lines, washing machine catch pan drain lines, or clothes dryer exhaust ducts. The inspector does not operate water supply or shut-off valves for sinks, toilets, bidets, clothes washers, etc. due to the possibility of valves leaking or breaking when operated. The inspector does not determine if shower pans or tub and shower enclosures are water tight, or determine the completeness or operability of any gas piping to laundry appliances.(no gas lines were found)
Location #A: Bath with shower
Location #B: Bath with tub
Condition of counters: Appeared serviceable
Condition of cabinets: Appeared serviceable
Condition of sinks and related plumbing: Appeared serviceable
Condition of toilets: Appeared serviceable
Condition of ventilation systems: Appeared serviceable
Condition of laundry facilities: Appeared serviceable
240 volt receptacle for laundry equipment present: Yes
33) The clothes dryer was equipped with a foil, accordion-type, flexible exhaust duct. The U.S. Consumer Product Safety Commission considers these types of ducts to be unsafe, and a fire hazard. These types of ducts can trap lint and are susceptible to kinks or crushing, which can greatly reduce the air flow. This duct should be replaced with a rigid or corrugated semi-rigid metal duct, and by a qualified contractor if necessary. Most clothes dryer manufacturers specify the use of a rigid or corrugated semi-rigid metal duct. For more information on dryer safety issues, visit:
http://www.cpsc.gov/CPSCPUB/PUBS/5022.html

34) The clothes dryer exhaust duct should be cleaned. Significant amounts of lint build up in the foil duct is a safety hazard due to the risk of fire from decreased air flow. This duct should be cleaned now and annually, or more often if necessary in the future. Some chimney sweeps or heating/cooling duct cleaners perform this service. For more information, visit:
http://www.cpsc.gov/CPSCPUB/PUBS/5022.html
http://chimneykeepers.com/dryerclean.html

35) One or more clothes washer supply hoses were . Significant water damage may occur if these hoses fail. Recommend replacing hoses with braided, stainless steel hoses.
Cost estimate: >$50.00

36) The exhaust fan at location #B was noisy. Moisture may accumulate as a result if the fan fails to operate. A qualified person should evaluate and repair or replace as necessary. Recommend replacing noisy fan.
Cost estimate: $ 100.00

37) No exhaust fan was installed in the laundry area. Exhaust fans in wet areas prevent moisture from accumulating, and causing mold growth and/or damage to building components. They are especially important in the relatively airtight houses that have been built recently. A qualified contractor should install an exhaust fan as per standard building practices. Recommend that a switch with a built-in timer be installed to control it.
38) Hardware such as hinges, latches or pulls were loose and/or missing at one or more cabinets at location #A, B. A qualified person should repair as necessary.
39) At location #B. The client(s) should consider repairing the bathtub facet internal seals. Facet leaks around control handle when turned on and should be repaired.
Cost estimate: >$50.00

40) Moderate wear was found at the sink at location #A, B.
41) The clothes washer was installed over a finished living space and had no catch pan or drain installed. These are not commonly installed, but they are recommended to prevent water damage to finished interior spaces below if or when the washing machine leaks, overflows or is drained. Recommend having a qualified contractor install both a catch pan and drain.
 
Interior Rooms / Areas Return to table of contents
Limitations: The following items are not included in this inspection: security, intercom and sound systems; communications wiring; central vacuum systems; elevators and stair lifts; sources of obnoxious odors; cosmetic deficiencies due to normal wear and tear in wall, floor and ceiling surfaces and coverings, or in equipment; deficiencies relating to interior decorating; low voltage and gas lighting systems. Any comments made regarding these items are as a courtesy only. Note that the inspector does not evaluate any areas or items which require moving stored items, furnishings, debris, equipment, floor coverings, insulation or similar materials. The inspector does not test for asbestos, lead, radon, mold, hazardous waste, urea formaldehyde urethane, or any other toxic substance. Some items such as window operability are tested on a sampled basis. The client should be aware that paint may obscure wall and ceiling defects, floor coverings may obscure floor defects, and furnishings may obscure wall, floor and floor covering defects. If furnishings were present during the inspection, recommend a full evaluation of walls, floors and ceilings that were previously obscured when possible. Determining the cause of odors is not within the scope of this inspection.
Exterior door material: Metal
Condition of exterior entry doors: Appeared serviceable
Condition of interior doors: Appeared serviceable
Type of windows: Casement
Condition of windows: Appeared serviceable
Wall type or covering: Drywall
Condition of walls: Appeared serviceable
Ceiling type or covering: Drywall
Condition of ceilings: Appeared serviceable
Flooring type or covering: Carpet, Vinyl, Tile
Condition of flooring: Appeared serviceable
42) Ceiling areas in this structure had ceiling texture possibly installed prior to 1980. This material may contain asbestos, which is a known carcinogen and poses a health hazard. Laws were passed in the United States in 1978 prohibiting use of asbestos in residential structures, but stocks of existing materials have been known to be used for some time thereafter. The client may wish to have this ceiling material tested by a qualified lab to determine if it does contain asbestos.

In most cases, when the material is intact and in good condition, keeping it encapsulated with paint and not disturbing it may reduce or effectively eliminate the health hazard. If the client wishes to remove the material, or plans to disturb it through remodeling, they should have it tested by a qualified lab and/or consult with a qualified industrial hygienist or asbestos abatement specialist. For more information, visit:
http://www.cpsc.gov/CPSCPUB/PUBS/453.html

43) One or more ceiling fans were installed less than seven feet from the floor below. This is a safety hazard. A qualified contractor should evaluate and repair as necessary. For example, remove fans, or move them as necessary to maintain a seven foot clearance below. Ideally ceiling fans should be installed at least eight to nine feet above the floor for optimal air flow.
44) The inspector was unable to verify that the glass used in one or more sliding glass doors, storm doors was approved safety glass. Glazing that is not approved safety glass located in areas subject to human impact is a safety hazard. Standard building practices generally require that approved safety glass be used in swinging and sliding doors except where "art glass", jalousie windows or glazing smaller than a three inch opening are used. A qualified contractor should evaluate and replace glass if necessary, and as per standard building practices.
45) This structure was built prior to 1979 and may contain lead paint. Laws were enacted in 1978 in the US preventing the use of lead paint in residential structures. Lead is a known safety hazard, especially to children but also to adults. The paint found in and around this structure appeared to be intact and may be encapsulated by more recent layers of paint that are not lead-based. Regardless, recommend following precautions as described in the following links to Consumer Products Safety Commission website articles regarding possible lead paint:
http://www.cpsc.gov/CPSCPUB/PUBS/5054.html
http://www.cpsc.gov/CPSCPUB/PUBS/5055.html

46) Some bedroom doors has no gap between it and the floor below, or has a gap substantially less than one inch. This structure has a forced air heating system with centrally located return air ducts. When bedroom doors are closed, the only effective path for return air out of the bedrooms is under the doors. A minimum gap of one inch below bedroom doors is recommended to allow an adequate air flow for return air. Recommend trimming the bottoms of bedroom doors as necessary so each door has a minimum one inch gap at its base.
47) Some windows that were built to open were difficult to open and close. A qualified person should evaluate and repair as necessary. Windows were checked in most rooms and some of them were difficult to open and close, Recommend operating all windows and use a dry lubricant to help them operate easier.
48) Screens in one or more windows were damaged. A qualified person should repair or replace screens as necessary. The bottom of some of the screens frames were bent up some in the center (about 1/4 inch) and should be straightened to help eliminate insect entry when windows are open.
49) Crank handles at windows were loose at some of the windows. A qualified person should repair or replace as necessary. Set screws need to be tightened on the window cranks that are loose.
 
Private Well Return to table of contents
Limitations: The inspector does not test private well water for contamination or pollutants, determine if the supply and/or flow are adequate, or provide an estimate for remaining life of well pumps, pressure tanks or equipment. Only visible components are evaluated. The client should have qualified lab test the well water for bacterial contaminants. A qualified well specialist should evaluate the well and perform a yield test.
Condition of private water supply: Appeared serviceable
Type of well: Drilled
Location of well: West side of house.
Source for information about the well: Property owner
Condition of pump: Appeared serviceable
Type of pump: Submersible
Submersible heavy duty pump relay at: Utility room in basement
Pump horsepower rating: 2 HP
Condition of well equipment: Appeared serviceable
Location of well equipment: Basement utility room
Location of tank shut off valve: Basement utility room
Condition of pressure tank: Appeared serviceable
50) The well casing was less than 12 inches above the ground. This is a potential source for contamination of the well water if debris enters the well casing. The surrounding soil should be graded with a positive slope, down and away from the well casing, so the casing rises at least 12 inches above grade to avoid contamination. Contact well repair company for recommendations and estimate.

Photo 3  
Well cap less than 12 inches from ground surface.
 

51) The inspector performed only a limited, visual evaluation of the private water supply system, including such items as the well head, well equipment, and pressure tank where visible. The inspector is not a well specialist, and did not determine if the well provides an adequate quantity of water, or if the water is safe to drink. A qualified specialist should perform a full evaluation of this system, and water samples should be tested by a qualified lab.
52) The well casing was less than 30 feet from the house. If a "barrier" treatment for termites has ever been applied or is applied in the future around the perimeter of the house this may contaminate the well water. Recommend asking the property owner about prior treatment for wood destroying insects, and consulting with a qualified well contractor as necessary.

Photo 2  
Well less than 30 feet from house.
 

53) Recommend having the well water tested for coliform bacteria, nitrates, and anything else of local concern, by a qualified lab. For more information, visit http://www.wellowner.org
54) No pressure relief valve was visible. Standard building practices require that one be installed to prevent damage to equipment if pressures get too high. A qualified contractor should evaluate and install one as necessary.
55) Recommend installing an insulating blanket around the pressure tank to prevent condensation from forming and causing the tank to corrode.
56) The estimated useful life for most well pumps is 15 to 20 years. Based on information provided to the inspector, or evidence found during the inspection, the well pump may be near this age and may need replacing at any time. Recommend budgeting for a replacement in the near future.
 
Electric Return to table of contents
Limitations: The following items are not included in this inspection: generator systems, surge suppressors, inaccessible or concealed wiring; underground utilities and systems; low voltage lighting or lighting on timers or sensors. Any comments made regarding these items are as a courtesy only. Note that the inspector does not determine the adequacy of grounding or bonding, does not determine if this system has an adequate capacity for the client's specific needs, nor determine if this system has any reserve capacity for additions or expansion. The inspector does not operate circuit breakers as part of the inspection, install or change light bulbs, nor determine the operability of every wall switch.
Electric service condition: Appeared serviceable
Primary service type: Underground
Number of service conductors: 3
Service voltage (volts): 120, 120
Service amperage (amps): 200
Primary service overload protection type: Circuit breakers
Service entrance conductor material: Not determined
Main disconnect rating (amps): 200
System ground: Not determined
Condition of main service panel: Appeared serviceable
Location of main service panel #A: BasementUtility room on the east wall
Location of main disconnect: Breaker at top of main service panel
Condition of smoke detectors: Appeared serviceable
Smoke detectors present: Yes
57) Extension cords were being used as permanent wiring in one or more areas. They should only be used for portable equipment on a temporary basis. Using extension cords as permanent wiring poses a fire and shock hazard, and is an indication that wiring is inadequate and should be updated. Extension cords may be undersized. Connections may not be secure, resulting in power fluctuations, damage to equipment, and sparks that could start a fire. Extension cords should be removed as necessary, or a qualified electrician should evaluate and make repairs as necessary. For example, install additional circuits and/or electric receptacles.
58) One or more electric receptacles at the kitchen, laundry room, garage, exterior had no visible ground fault circuit interrupter (GFCI) protection. This is a safety hazard due to the risk of shock. Recommend having a qualified electrician evaluate to determine if GFCI protection exists, and if not, repair as necessary. For more information, visit:
http://www.mikeholt.com/documents/nec/pdf/GFCI_requirement_page2.pdf

59) Batteries in all the smoke alarms should be replaced after taking occupancy, and annually in the future. "Chirping" noises emitted from smoke alarms typically indicate that batteries need replacing. For more information, visit:
http://www.cpsc.gov/cpscpub/pubs/5077.html

60) Branch circuit wiring installed in buildings built prior to the mid 1980s is typically rated for a maximum temperature of only 60 degrees Centigrade. This includes non-metallic sheathed (Romex) wiring, and both BX and AC metal clad flexible wiring. Knob and tube wiring, typically installed in homes built prior to 1950 may be rated for even lower maximum temperatures. Newer electric fixtures including lighting and fans typically require wiring rated for 90 degrees Centigrade. Connecting older, 60 degree-rated wiring to such newer fixtures is a potential safety hazard due to the risk of fire. Repairs for such conditions often involve replacing the last few feet of wiring to newer fixtures with new 90 degree-rated wire. This often requires installing a junction box to join the old and new wiring.

It is beyond the scope of this inspection to determine if such incompatible components are installed, or to determine the extent to which they're installed. Based on the age of this building, the client should be aware that this safety hazard may be present in this building. Recommend consulting with the property owner to determine if and when newer fixtures were installed, and/or to have a qualified electrician evaluate and repair as per standard building practices.
 
Plumbing / Fuel Systems Return to table of contents
Limitations: The following items are not included in this inspection: private wells and sewage disposal systems; main, side and lateral sewer lines; gray water systems; pressure boosting systems; incinerating or composting toilets; fire suppression sprinkler systems; water softeners, conditioners or filtering systems; plumbing components concealed within the foundation or building structure, or in inaccessible areas such as below tubs; underground utilities and systems; overflow drains for tubs and sinks; backflow prevention devices. Any comments made regarding these items are as a courtesy only. Note that the inspector does not operate water supply or shut-off valves due to the possibility of valves leaking or breaking when operated. The inspector does not test for lead in the water supply, the water pipes or solder, does not determine if plumbing and fuel lines are adequately sized, and does not determining the existence or condition of underground or above-ground fuel tanks.
Condition of drain pipes: Appeared serviceable
Drain pipe material: Plastic
Condition of waste lines: Appeared serviceable
Waste pipe material: Plastic
Vent pipe condition: Appeared serviceable
Vent pipe material: Plastic
61) Water supply lines were routed outside and are subject to freezing. The client should ask the property owner if inside shut-off valves exist for these supply pipes. If unable to determine if shut-off valve(s) exist, or if none do, then a qualified plumber should evaluate and install interior shut-off valves as necessary to prevent pipes from freezing and bursting.
62) Recommend having the septic tank inspected by a qualified specialist, and repaired if necessary. Recommend having the tank pumped if it was last pumped more than 3 years ago.
63) A water softener system was installed on the premises. Only a limited evaluation of this system was performed during the inspection. The client should consult with the property owner on this system to determine its condition, required maintenance, age and expected remaining life, etc.
64) This property had both a septic system and a water softener system, and the water softener's discharge line appeared to be routed into the septic waste line. There is some debate as to whether this configuration is advisable because of the following:

  • Salt in the discharge water may kill the needed bacteria, causing sludge to build up, and possibly plugging the lines.
  • Salt may interact with clay in the leach field soil and cause the water to not disperse.
  • The discharge cycle may disturb the septic tank when it cycles (usually at night), and prevent sludge from settling, resulting in sludge escaping from the tank.
  • Marginally sized septic tanks can be overwhelmed by the volume of water during the discharge cycle and may cause sludge to escape.

    Recommend that the client consult with one or more contractors who specialize in septic systems and water softeners for more information.
    65) A sump pump was installed in the basement. This may indicate that water accumulates inside or below the structure. Recommend asking the property owner how often the sump pump operates and for how long at different times of the year. Also, the client should be aware that the service life of most sump pumps is between five and seven years, and that the pump may need replacing soon depending on its age and how often it operates.
     

    Photo 4  
    Cap installed on chimney. Recommend that if fire place or wood burning stove were to be installed in the future; the chimney be inspected by qualified chimney sweep.

    Photo 6  
    Electrical and communication cable were located in covered area.

    Photo 7  
    Shower floor and walls looked good at time of inspection.

    Photo 9  
    No GFI plugs were found in in kitchen.

    Photo 12  

    Photo 14  
    Roof was in good condition.

    Photo 17  

    Photo 24  
    Septic tank cap in back yard.

     
    .