Website: http://www.michiganmoldtesting.com
Company email: Info@michiganmoldtesting.com
Inspector's email: Matt@michiganmoldtesting.com
Phone: (734) 331-3269
41168 Northwind Dr 
Canton MI 48188-1313
Inspector: Matt Cottenham
interNACHI Certified

 

Property Inspection Report
Client(s): John Doe
Property address: 1111 Your Street
Canton MI 48188
Inspection date: 3/26/2000
This report published on Tuesday, March 22, 2011 10:09:32 AM EDT

View summary page

This report is the exclusive property of Trademark Home Inspection company and the client(s) listed in the report title. Use of this report by any unauthorized persons is prohibited.

 
How to Read this Report
This report is organized by the property's functional areas.  Within each functional area, descriptive information is listed first and is shown in bold type.  Items of concern follow descriptive information.
Concerns are shown and sorted according to these types:
SafetyPoses a risk of injury or death 
Major DefectCorrection likely involves a significant expense 
Repair/ReplaceRecommend repairing or replacing 
Repair/MaintainRecommend repair and/or maintenance 
Minor DefectCorrection likely involves only a minor expense 
MaintainRecommend ongoing maintenance 
EvaluateRecommend evaluation by a specialist 
MonitorRecommend monitoring in the future 
CommentFor your information 

Click here for a glossary of building construction terms.  Contact your inspector if there are terms that you do not understand, or visit the glossary of construction terms at http://www.reporthost.com/glossary.asp

Table of Contents
General information
Exterior
Roof
Garage
Attic
Electric service
Water heater
Heating and cooling
Plumbing and laundry
Fireplaces, woodstoves and chimneys
Basement
Kitchen
Bathrooms
Interior rooms
 
General information Return to table of contents
Inspector's name: Matthew D Cottenham
Type of building: Single family
Age of building: 57 years
Inspection Fee: $200.00
Payment method: Cash
Present during inspection: Client(s), Realtor(s)
Occupied: No
Weather conditions: Clear
Temperature: Cool
Ground condition: Damp
Foundation type: Unfinished basement, Finished basement
1) This property has one or more fuel burning appliances, and no carbon monoxide alarms are visible. This is a safety hazard. Recommend installing one or more carbon monoxide alarms as necessary and as per the manufacturer's instructions. For more information, visit http://www.cpsc.gov/CPSCPUB/PREREL/prhtml05/05017.html
2) Structures built prior to 1979 may contain lead-based paint and/or asbestos in various building materials such as insulation, siding, and/or floor and ceiling tiles. Both lead and asbestos are known health hazards. Evaluating for the presence of lead and/or asbestos is not included in this inspection. The client(s) should consult with specialists as necessary, such as industrial hygienists, professional labs and/or abatement contractors for this type of evaluation. For information on lead, asbestos and other hazardous materials in homes, visit these websites:
  • The Environmental Protection Association (http://www.epa.gov)
  • The Consumer Products Safety Commission (http://www.cpsc.gov)
  • The Center for Disease Control (http://www.cdc.gov)
     
    Exterior Return to table of contents
    Footing material: Not visible
    Foundation material: Poured in place concrete
    Apparent wall structure: Wood frame
    Wall covering: Brick veneer, Metal
    Driveway material: Poured in place concrete
    Sidewalk material: Poured in place concrete
    Exterior door material: Solid core wood
    3) One or more trip hazards were found in sidewalk and/or patio sections due to cracks, settlement and/or heaving. A qualified contractor should evaluate and repair or replace sidewalk and/or patio sections as necessary to eliminate trip hazards.

    Photo 64  
     

    4) Trip hazard(s) exist at stairs due to non-uniform riser heights. Standard building practices call for riser heights not to vary more than 3/8 inch on a flight of stairs. At a minimum, the client(s) should be aware of this hazard, especially when guests who are not familiar with the stairs are present. Ideally a qualified contractor should evaluate and repair or replace stairs so all riser heights are within 3/8 inch of each other.

    Photo 21  
     

    5) Screen door located on the front door rubs the fascia trim. this could pose a safety hazard.

    Photo 32  
     

    6) One or more hornet, bee and/or wasp nests were found. These can pose a safety hazard. Nest(s) should be removed as necessary.
    7) The driveway has significant cracks and/or deterioration in one or more areas. A qualified contractor should evaluate and repair or replace driveway sections as necessary.

    Photo 65  
     

    8) One or more gutters are poorly sloped so that significant amounts of water accumulate in them rather than draining through the downspouts. This can cause gutters to overflow, especially when organic debris such as leaves or needles have accumulated in them. A qualified contractor should evaluate and make repairs as necessary, such as correcting the slope in gutters or installing additional downspouts and extensions if necessary.
    9) Rot was found in one or more areas on soffit boards. A qualified contractor should evaluate and make repairs as necessary, replacing all rotten wood.

    Photo 4  
     

    10) Fascia boards are damaged or deteriorated in one or more areas. A qualified contractor should evaluate and make repairs as necessary.
    11) Rot was found in one or more areas on fascia boards. A qualified contractor should evaluate and make repairs as necessary, replacing all rotten wood.
    12) The perimeter grading slopes towards the structure in one or more areas. This can result in water accumulating around the structure's foundation, or in basements and crawl spaces if they exist. Accumulated water is a conducive condition to wood destroying insects and organisms. Wet soil may also cause the foundation to settle and possibly fail over time. Recommend grading soil so it slopes down and away from the structure with a slope of at least 5% (10% or better is optimal) for at least 6 feet.

    Photo 3  

    Photo 7  

    13) One or more downspouts have no extensions, or have extensions that are ineffective. This can result in water accumulating around the structure's foundation, or in basements and crawl spaces if they exist. Accumulated water is a conducive condition to wood destroying insects and organisms, and may also cause the foundation to settle and possibly fail over time. Repairs should be made as necessary, such as installing or repositioning splash blocks, or installing and/or repairing tie-ins to underground drain lines, so rain water is carried at least several feet away from the structure to soil that slopes down and away from the structure.

    Photo 7  
     

    14) One or more gutters are damaged. This can result in water accumulating around the structure's foundation, or in basements and crawl spaces if they exist. Accumulated water is a conducive condition to wood destroying insects and organisms, and may also cause the foundation to settle and possibly fail over time. A qualified contractor should replace or repair gutters where necessary.

    Photo 4  
     

    15) One or more gutters were leaking during the inspection. This can result in water accumulating around the structure's foundation, or in basements and crawl spaces if they exist. Accumulated water is a conducive condition to wood destroying insects and organisms, and may also cause the foundation to settle and possibly fail over time. A qualified contractor should replace or repair gutters where necessary.
    16) Gaps exist at one or more openings around the exterior, such as those where outside faucets, refrigerant lines, and/or gas supply pipes penetrate the exterior. Gaps should be sealed as necessary to prevent moisture intrusion and entry by vermin.

    Photo 13  

    Photo 14  

    Photo 15  

    Photo 16  

    17) One or more outside faucets aren't anchored securely to the structure's exterior. Fasteners should be installed or replaced as necessary so faucets are securely anchored to prevent stress on plumbing supply lines and possible leaks.
    18) Recommend replacing entire gutter system on home.
    19) Vegetation such as trees, shrubs and/or vines are in contact with or less than one foot from the structure's exterior. Vegetation can serve as a conduit for wood destroying insects and may retain moisture against the exterior after it rains. Vegetation should be pruned and/or removed as necessary to maintain a one foot clearance between it and the structure's exterior.
    20) Caulk is missing or deteriorated in some areas and should be replaced and/or applied where necessary. For more information on caulking, visit:
    The Ins and Outs of Caulking.
     
    Roof Return to table of contents
    Roof inspection method: Viewed from ground with binoculars
    Roof type: Cross gable, Hipped
    Roof covering: Asphalt or fiberglass composition shingles
    Estimated age of roof: 15-20 yrs
    Gutter & downspout material: Aluminum
    Roof ventilation: Inadequate
    21) The roof surface material is beyond or at the end of its service life and needs replacing now. The client(s) should consult with a qualified roofing contractor to determine replacement options and costs.

    Photo 6  

    Photo 8  

    Photo 9  
     

    22) One or more sections of roof flashing are deteriorated and/or rusted. Leaks may occur as a result. A qualified roofing contractor should evaluate and replace flashing where necessary.

    Photo 29  
     

    23) Debris such as leaves, needles, seeds, etc. have accumulated on the roof. This is a conducive condition for wood destroying insects and organisms since water may not flow easily off the roof, and may enter gaps in the roof surface. Leaks may occur as a result. Debris should be cleaned from the roof now and as necessary in the future.
     
    Garage Return to table of contents

    24) Weatherstrip around or at the bottom of the garage-house door is damaged or deteriorated. It should be replaced as necessary to prevent vehicle fumes from entering living spaces.
    25) Weatherstrip at the sides and/or bottom of the vehicle door is damaged and/or deteriorated. It should be replaced where necessary to prevent water and vermin intrusion.
    26) The concrete floor will eventually need repaired or replaced do to major cracking ans sinking.

    Photo 63  
     

    27) Unable to operate vechical door do to padlock. Observed uneven concrete not allowing it to seal against the concrete.

    Photo 62  
     
     
    Attic Return to table of contents
    Inspection method: Viewed from hatch
    Roof structure type: Rafters
    Ceiling structure: Ceiling beams
    Insulation material: Cellulose loose fill
    Insulation depth: 1-3 inches
    Insulation estimated R value: R-5
    28) Ventilation is substandard in the attic. Inadequate attic ventilation may result in high attic and roof surface temperatures, reduce the life of the roof covering materials and increase cooling costs. High levels of moisture are also likely, and can be a conducive condition for wood destroying insects and organisms. Standard building practices require one square foot of vent area for 150 to 200 square feet of attic space. Vents should be evenly distributed between soffits, ridges and at corners to promote air circulation. A qualified contractor should evaluate and install vents as per standard building practices.
    29) No weatherstrip is installed around the attic access hatch. Weatherstrip should be installed around the hatch to prevent heated interior air from entering attic.
     
    Electric service Return to table of contents
    Primary service type: Overhead
    Primary service overload protection type: Fuses
    Service amperage (amps): 100
    Service voltage (volts): 120/240
    Location of main service switch: Basement
    Location of sub panels: Basement
    Location of main disconnect: Breaker at top of main service panel
    Service entrance conductor material: Aluminum
    Main disconnect rating (amps): 100
    Branch circuit wiring type: Copper
    Smoke detectors present: Yes
    30) The electric service to this property appears to be rated at substantially less than 200 amps, and may be inadequate for the client(s) needs. Recommend consulting with a qualified electrician about upgrading to a 200 amp service.
    31) Main service panel in basement

    Photo 53  

    Photo 54  

    32) Sub panel in basement

    Photo 57  
     
     
    Water heater Return to table of contents
    Estimated age: 10-15 yrs
    Type: Tank
    Energy source: Natural gas
    Capacity (in gallons): 40
    Manufacturer: Reliance
    33) No drain line is installed for the temperature-pressure relief valve. This is a potential safety hazard due to the risk of scalding if someone is standing next to the water heater when the valve opens. A qualified plumber should install a drain line as per standard building practices. For example, extending to 6 inches from the floor, or routed so as to drain outside.
    34) The estimated useful life for most water heaters is 8 to 12 years. This water heater appears to be at this age or older and may need replacing at any time. Recommend budgeting for a replacement in the near future.
    35) Water stains were found below the water heater. This may be a sign that the water heater is failing. A qualified plumbing contractor should evaluate and replace or repair the water heater if necessary.
     
    Heating and cooling Return to table of contents
    Estimated age: 15-20 yrs
    Primary heating system energy source: Natural gas
    Primary heat system type: Forced air
    Primary A/C energy source: Electric
    Primary Air conditioning type: Split system
    Distribution system: Sheet metal ducts
    Manufacturer: Goodman
    Filter location: At the base of the furnace
    36) The estimated useful life for most forced air furnaces is 15 to 20 years. This furnace appears to be at this age or older and may need replacing at any time. Recommend budgeting for a replacement in the near future.
    37) The outdoor air temperature was below 60 degrees Fahrenheit during the inspection. Because of this, the inspector was unable to operate and fully evaluate the cooling system.
    38) Outside condensing unit

    Photo 11  

    Photo 12  

    39) Furnace tag

    Photo 58  

    Photo 59  
     
    Plumbing and laundry Return to table of contents
    Location of main water shut-off valve: Basement
    Location of main water meter: Basement
    Location of main fuel shut-off: Front Yard
    Water service: Public
    Service pipe material: Not visible
    Supply pipe material: Copper
    Vent pipe material: Not visible
    Drain pipe material: Plastic, Galvanized steel
    Waste pipe material: Plastic, Galvanized steel
    40) Copper water supply pipes in homes built prior to 1986 may be joined with solder that contains lead. Lead is a known health hazard, especially for children. Laws were passed in 1985 prohibiting the use of lead in solder, but prior to that solder normally contained about 50 percent lead. The client(s) should be aware of this, especially if children will be living in this structure. Evaluating for the presence of lead in this structure is not included in this inspection. The client(s) should consider having a qualified lab test for lead, and if necessary take steps to reduce or remove lead from the water supply. Various solutions such as these may be advised:

  • Flush water taps or faucets. Do not drink water that has been sitting in the plumbing lines for more than six hours.
  • Install appropriate filters at points of use.
  • Use only cold water for cooking and drinking. Hot water dissolves lead more quickly than cold water.
  • Use bottled or distilled water.
  • Treat well water to make it less corrosive.
  • Have a qualified plumbing contractor replace supply pipes and/or plumbing components as necessary.

    For more information visit:
    http://www.cpsc.gov/CPSCPUB/PUBS/5056.html
    http://www.epa.gov/safewater/lead/index.html
    41) No clothes dryer exhaust duct is installed. Clothes dryers produce large amounts of moisture which should not enter structure interiors. Damage to building components may result. A rigid or semi-rigid metal exhaust duct should be installed as per standard building practices, and by a qualified contractor if necessary. For information, visit:
    http://www.cpsc.gov/CPSCPUB/PUBS/5022.html

    42) Neither the clothes washer nor dryer were operated or evaluated. They are excluded from this inspection.
     
    Fireplaces, woodstoves and chimneys Return to table of contents
    Chimney type: Masonry
    43) Chimney cap needs replaced

    Photo 9  
     
     
    Basement Return to table of contents
    Pier or support post material: Steel
    Floor structure above: Solid wood joists
    44) Evidence of prior water intrusion was found in one or more sections of the basement. For example, water stains and/or efflorescence on the foundation or floor, water stains at bases of support posts, etc. Accumulated water is a conducive condition for wood destroying insects and organisms and should not be present in the basement. The client(s) should review any disclosure statements available and ask the property owner(s) about past accumulation of water in the basement. The basement should be monitored in the future for accumulated water, especially after heavy and/or prolonged periods of rain. If water is found to accumulate, a qualified contractor who specializes in drainage issues should evaluate and repair as necessary. Typical repairs for preventing water from accumulating in the basement include:

  • Repairing, installing or improving rain run-off systems (gutters, downspouts and extensions or drain lines)
  • Improving perimeter grading
  • Repairing, installing or improving underground footing and/or curtain drains

    Ideally, water should not enter the basement, but if water must be controlled after it enters the basement, then typical repairs include installing sump pump(s) or interior perimeter drains.

    Photo 55  

    Photo 56  

    45)   Replace all basement windows recommend using glass block.

    Photo 3  
     
     
    Kitchen Return to table of contents

    46) The range hood fan is inoperable. A qualified contractor should evaluate and repair or replace the fan or the range hood as necessary.

    Photo 37  
     

    47) Water stains and/or minor water damage was found in the shelving or cabinet components below the sink. t appears the source has been fixed.

    Photo 33  

    Photo 34  

    Photo 35  

    Photo 36  
     
    Bathrooms Return to table of contents

    48) One or more bathrooms with a shower do not have an exhaust fan installed. Moisture accumulation will occur and may damage the structure. Even if the bathroom has a window that opens, it likely does not provide adequate ventilation, especially during cold weather when the window is closed. A qualified contractor should install exhaust fans as per standard building practices where missing in bathrooms with showers.

    Photo 50  
     

    49) Caulk is missing and/or deteriorated at one or more bathtubs. For example, where the tub base meets the floor below, where the tub surround meets the tub, and/or around the base of the tub spout. Caulk should be replaced where deteriorated and/or applied where missing to prevent water intrusion and damage to wall and floor structures.
    50)   GFCI is wired to the bathromm light have a qualified electrician wire correctly.

    Photo 45  

    Photo 46  
     
    Interior rooms Return to table of contents

    51) Two-pronged electric receptacles rather than three-pronged, grounded receptacles are installed in one or more interior rooms. They are considered to be unsafe by today's standards and limit the ability to use appliances that require a ground in these rooms. Examples of appliances that require grounded receptacles include:

  • Computer hardware
  • Refrigerators
  • Freezers
  • Air conditioners
  • Clothes washers
  • Clothes dryers
  • Dishwashers
  • Kitchen food waste disposers
  • Information technology equipment
  • Sump pumps
  • Electrical aquarium equipment
  • Hand-held motor-operated tools
  • Stationary and fixed motor-operated tools
  • Light industrial motor-operated tools
  • Hedge clippers
  • Lawn mowers

    This list is not exhaustive. A qualified electrician should evaluate and install grounded receptacles as per the client(s)' needs and standard building practices.

    Photo 39  

    Photo 42  

    52) Batteries in all the smoke alarms should be replaced after taking occupancy, and annually in the future. "Chirping" noises emitted from smoke alarms typically indicate that batteries need replacing. For more information, visit:
    http://www.cpsc.gov/cpscpub/pubs/5077.html

    53) Seals between double-pane glass in one or more sliding glass doors appear to have failed based on condensation or stains between the panes of glass. A qualified contractor should evaluate and replace glass where necessary.

    The client(s) should be aware that evidence of broken seals may be more or less visible from one day to the next depending on the temperature, humidity, sunlight, etc. Glass doors or windows other than those that the inspector identified may also have failed seals and need glass replaced too.

    54) Stains were found in one or more ceiling areas. However, no elevated levels of moisture were found. The stain(s) may be due to past roof and/or plumbing leaks. Recommend asking the property owner(s) about this, and monitoring the stained area(s) in the future, especially after heavy or prolonged rain. If elevated moisture is found in the future, a qualified contractor should evaluate and repair as necessary.

    Photo 40  

    Photo 41  

    Photo 44  
     

    55) Minor cracks were found in walls in one or more areas. They do not appear to be a structural concern, but the client(s) may wish to repair these for aesthetic reasons.
     

    Photo 2  

    Photo 5  
    Gutter system is beyond repair and needs replacing.

    Photo 10  
    Re-insulate line on A/C condensing unit

    Photo 17  
    Breezeway needs to be evaluated by structural engineer for proper support.

    Photo 18  
    Seal all gaps around siding and exposed wood.

    Photo 19  
    Basement windows need replaced.

    Photo 20  
    Re-seal gap between front porch and house.

    Photo 22  
    Gas meter and main gas shut off next to front porch.

    Photo 23  
    Chimney cap needs replacing.

    Photo 24  

    Photo 25  
    Electric mast on driveway side of breezeway

    Photo 26  

    Photo 27  

    Photo 28  

    Photo 30  

    Photo 31  

    Photo 38  

    Photo 43  

    Photo 47  

    Photo 48  

    Photo 49  

    Photo 51  
    Cable line ran through cold air return/Re-route

    Photo 52  
    Water meter and shut off in basement

    Photo 60  

    Photo 61  

    Photo 66  

    Photo 67  

    Photo 68  

    Photo 69  

    Photo 70  
    Replace with programmable t-stat recommended

     
    Trademark Home Inspection