Photo 1
Termite trail where wall stud meets exterior sheathing. This is in the utility room and live termites were witnessed at this location.
|

Photo 4
Gas line entering attic through the soffit on the front of home.
|

Photo 5
Improperly installed gas line. This line goes from the utility room in rear of home, up through the attic where it is contact with electrical wiring and down the front wall of the home on the exterior. This line supplies gas for the fireplace and it is a safety hazard in more ways than one.
|

Photo 9
Gap between floor of front porch and wall should be sealed to prevent water from entering.
|

Photo 15
Spalling and cracking of the mortar between bricks, probably due to inadequate grading and the bricks not being installed with sufficent angle to allow water runoff during rain.
|

Photo 22
Plumbing for the washing machine not properly secured. May cause rattling of pipes and possibly damage if left uncorrected.
|

Photo 24
Termite damage in utility room. The inspector and the client witnessed live termites during the inspection.
|

Photo 25
Apparent leak underneath bath tub as evidenced by the rust. Hole should be sealed to prevent entry by animals or insects and to prevent cold air from entering.
|

Photo 29
Rotted door sill due to improper grading. Water flows from walkway and yard directly to this door way.
|
|