Inspector: David Taylor

 

Property Inspection Report
Client(s): David Taylor
Property address: 339 Oak Ct.
Loganville, GA. 30052
Inspection date: Saturday, August 29, 2009
This report published on 9/11/2009 8:43:44 AM EDT

View summary page

This report is the exclusive property of this inspection company and the client(s) listed in the report title. Use of this report by any unauthorized persons is prohibited.

 
How to Read this Report
This report is organized by the property's functional areas.  Within each functional area, descriptive information is listed first and is shown in bold type.  Items of concern follow descriptive information. Concerns are shown and sorted according to these types:
SafetyPoses a risk of injury or death 
Repair/ReplaceRecommend repairing or replacing 
MaintainRecommend ongoing maintenance 
EvaluateRecommend evaluation by a specialist 
CommentFor your information 

Structural Pest Inspection Concerns
Items of concern relating to the structural pest inspection are shown as follows:
WDO/WDI InfestationEvidence of infestation of wood destroying insects or organisms (Live or dead insect bodies, fungal growth, etc.) 
WDO/WDI DamageDamage caused by wood destroying insects or organisms (Rot, carpenter ant galleries, etc.) 
WDO/WDI Conducive
conditions
Conditions conducive for wood destroying insects or organisms (Wood-soil contact, shrubs in contact with siding, roof or plumbing leaks, etc.) 

Click here for a glossary of building construction terms.  Contact your inspector if there are terms that you do not understand, or visit the glossary of construction terms at http://www.reporthost.com/glossary.asp

Table of Contents
General information
Exterior
Roof
Attic
Electric service
Water heater
Heating and cooling
Plumbing and laundry
Fireplaces, woodstoves and chimneys
Kitchen
Bathrooms
Interior rooms
 
General information Return to table of contents
Report number: 100111
Inspector's name: David Taylor
Structures inspected: Residential
Type of building: Single family
Age of building: 2007 New
Time started: 12:30
Time finished: 4:30
Inspection Fee: 245.00
Payment method: Check#1643
Present during inspection: Client(s)
Occupied: No, but furnishings and stored items are present
Weather conditions: Clear
Temperature: Warm
Ground condition: Damp
Foundation type: Slab on grade
1)   This property has one or more fuel burning appliances, and no carbon monoxide alarms are visible. This is a safety hazard. Recommend installing one or more carbon monoxide alarms as necessary and as per the manufacturer's instructions. For more information, visit http://www.cpsc.gov/CPSCPUB/PREREL/prhtml05/05017.html
2)   The natural gas service was turned off. As a result, some appliances such as water heater(s), forced air furnace(s), gas fireplace(s), stove(s), range(s) and/or gas supply lines weren't fully evaluated. The inspector was unable to test for gas leaks.

Photo 27  
 
 
Exterior Return to table of contents
Footing material: Poured in place concrete
Foundation material: Poured in place concrete
Apparent wall structure: Wood frame
Wall covering: Cement-based clapboard, Brick veneer
Driveway material: Poured in place concrete
Sidewalk material: Poured in place concrete
Exterior door material: Solid core fiberglass, Glass panel
3)   One or more outdoor electric receptacles appear to have no ground fault circuit interrupter (GFCI) protection. This is a safety hazard due to the risk of shock. A qualified electrician should evaluate to determine if GFCI protection exists, and if not, repairs should be made so that all outdoor receptacles within six feet six inches of ground level have GFCI protection. For example, install GFCI receptacles or circuit breaker(s) as needed. Missing receptacle.

Photo 19  
 

4) One or more gutters are missing. This can result in water accumulating around the structure's foundation, or in basements and crawl spaces if they exist. Accumulated water is a conducive condition to wood destroying insects and organisms, and may also cause the foundation to settle and possibly fail over time. A qualified contractor should install gutters and downspouts where missing. Also, extensions such as splashblocks or tie-ins to underground drain lines should be installed as necessary to carry rain water away from the house.

Photo 1  
 

5) Siding is incomplete or missing in one or more areas. A qualified contractor should install siding where missing to prevent water and vermin intrusion.

Photo 25  
 

6) Caulk is missing or deteriorated in some areas and should be replaced and/or applied where necessary. For more information on caulking, visit:
The Ins and Outs of Caulking.

Photo 20  

Photo 31  
 
Roof Return to table of contents
Roof inspection method: Viewed from ground with binoculars
Roof type: Gable
Roof covering: Asphalt or fiberglass composition shingles
Estimated age of roof: 2007
Gutter & downspout material:
Roof ventilation: Adequate
7) One or more "rubber boot" flashings are lifting at the base or are improperly installed so that water or vermin intrusion may occur. A qualified contractor should make repairs as necessary, such as permanently fastening down the lifted edge(s), or reinstalling flashings.

Photo 28  
 

8)   General pictures of the roof.

Photo 22  

Photo 23  

Photo 24  

Photo 26  

Photo 29  

Photo 30  
 
Attic Return to table of contents
Inspection method: Partially traversed
Roof structure type: Rafters
Ceiling structure: Ceiling beams
Insulation material: Fiberglass loose fill
Insulation estimated R value: R-30
9)   Pull-down stairs are installed for the attic access. No insulation is installed above the stairs and no weatherstripping is installed around the hatch perimeter. To reduce air leakage, recommend installing weatherstripping and an insulated hatch cover. An example of one can be seen at http://www.batticdoor.com/

Interior air leaking into the attic results in heating and cooling losses, increased energy costs, and a possible increase in moisture levels in the attic due condensation forming on the underside of the roof sheathing during cold weather.

Photo 5  
 

10)   Some attic areas were inaccessible due to lack of permanently installed walkways, the possibility of damage to insulation, low height and/or stored items. These areas are excluded from this inspection.

Photo 7  

Photo 8  

Photo 9  

Photo 10  

Photo 11  

Photo 12  
 
Electric service Return to table of contents
Primary service type: Underground
Primary service overload protection type: Circuit breakers
Service amperage (amps): 150
Service voltage (volts): 120/240
Location of main service switch: Meter
Location of main disconnect: No single main disconnect, use all breakers in main service panel
Service entrance conductor material: Aluminum
System ground: Ground rod(s) in soil
Smoke detectors present: Yes
11)   Main disconnect and electrical panel.

Photo 17  

Photo 21  
 
Water heater Return to table of contents
Estimated age: 2008
Type: Tank
Energy source: Natural gas
Capacity (in gallons): 50
Manufacturer: State
Model: 22V50F1
12)   The water heater was turned off at the time of the inspection. For example, circuit breaker turned off, gas supply turned off or pilot light turned off. The inspector was unable to fully evaluate the water heater. No gas.

Photo 16  
 
 
Heating and cooling Return to table of contents
Estimated age: 2007 New
Primary heating system energy source: Natural gas
Primary heat system type: Forced air
Primary A/C energy source: Electric
Primary Air conditioning type: N/A
Distribution system: Flexible ducts
Manufacturer: AmanaDucane
Model: MPGA100B45, GSC130481AC
Filter location: At the base of the furnace
13)   Air handler filter(s) should be checked monthly in the future and replaced or washed as necessary.

Photo 2  
 

14)   The furnace was shut off at the time of the inspection. For example, the gas supply was shut off, the pilot light was out, and/or the electric supply was turned off. As a result, the inspector was unable to fully evaluate this unit. No gas.

Photo 6  
 

15)   The A/C unit was functional at the time of inspection.

Photo 18  
 
 
Plumbing and laundry Return to table of contents
Location of main water shut-off valve: Meter
Location of main water meter: Street
Location of main fuel shut-off: Meter
Water service: Public
Service pipe material: Not visible
Supply pipe material: Not visible
Vent pipe material: Plastic
Drain pipe material: Plastic
Waste pipe material: Plastic
16)   Hose bibb shut-off valve.

Photo 3  
 
 
Fireplaces, woodstoves and chimneys Return to table of contents
Fireplace type: Metal prefabricated
Chimney type: Metal
17)   All solid fuel burning appliances (woodstoves and fireplaces, etc.) should be inspected annually by a qualified chimney service contractor, cleaned and repaired as necessary.

Photo 13  
 
 
Kitchen Return to table of contents

18)   The appliances were not installed at the time of inspection.

Photo 15  
 
 
Bathrooms Return to table of contents

19)   The enamel coating on one or more bathtubs is damaged and/or deteriorated. For example, chipped or worn, and/or rust on some exposed steel. However, no leaks were found due to the deterioration. The client(s) should evaluate to determine if the bathtub(s) should be refinished or replaced. Upstairs bath.

Photo 4  
 
 
Interior rooms Return to table of contents

20)   One or more exterior entrance doors are damaged and/or deteriorated and should be repaired or replaced by a qualified contractor.

Photo 14  
 

 
Your default report CONTRACT AGREEMENT

THE CLIENT: refers to the person or entity on whose behalf a Home Inspector is acting or paying for the inspection and/or signing agreements.

THE COMPANY: refers to the person or business conducting the Home Inspection service for THE CLIENT for a fee

THE CLIENT has read and agreed to all of the following:

An inspection is intended to assist in evaluation of the overall condition of a building. The inspection is based on observation of the visible and apparent condition of the building and its components on the date of inspection. The results of this home inspection are not intended to make any representation regarding latent or concealed defects that may exist, and no warranty or guarantee is expressed or implied. If the person conducting your home inspection is not a licensed structural engineer or other professional whose license authorizes the rendering of an opinion as to the structural integrity of a building or its other component parts, you may be advised to seek a professional opinion as to any defects or concerns mentioned in this report.

The inspection will be performed in a manner consistent with a set of written standards of practice determined by the home inspection company. The inspection and report are solely for the use of THE CLIENT and THE COMPANY, and are not transferable to, or for the benefit of a third party under any circumstances. THE COMPANY assumes no responsibilty for any future usage of the report.

This report is intended solely to assist THE CLIENT in evaluating the overall general condition of the building. THE CLIENT understands an older component may be at or nearing the end of its statistical and/or useful life and could fail at any time after the inspection. Although proper care has been taken in performing this inspection, this inspection and report cannot be fully exhaustive, nor does it imply that every component was inspected or that every possible defect was discovered.

THE CLIENT understands this inspection is to assist THE CLIENT in making a more informed purchasing decision, and is not to find all defects. THE CLIENT understands a seperate warranty may be available through another agency. The findings of this inspection are valid for the date of actual inspection only. THE COMPANY shall not be held responsible for items or problems concealed, hidden, or inaccessible during the inspection.

Limitation of Liability

THE CLIENT agrees to limit any claim of liability for personal injury or property damage caused by any negligence of THE COMPANY or its agents to one time the amount of the original inspection fee.