Summary Page
| Structural Pest & Home Inspection Report | |
| Client(s): | xxxxxxxx |
| Property address: | xxxxxxxx xxxxxx xxxx xx |
| Inspection date: | Tuesday 19th April 2005 |
![]() | Safety | Poses a risk of injury or death |
![]() | Major defect | Correction likely involves a significant expense |
![]() | Repair/Replace | Recommend repairing or replacing |
![]() | Repair/Maintain | Recommend repair and/or maintenance |
![]() | Evaluate | Recommend evaluation by a specialist |
![]() | Serviceable | Item or component is in serviceable condition |
![]() | Comment | For your information |
![]() | Infestation | Evidence of infestation of wood destroying insects or organisms (Live or dead insect bodies, fungal growth, etc.) |
![]() | Damage | Damage caused by wood destroying insects or organisms (Rot, carpenter ant galleries, etc.) |
![]() | Conducive conditions | Conducive conditions for wood destroying insects or organisms. (Wood-soil contact, shrubs in contact with siding, roof or plumbing leaks, etc.) |


- Overall this house is "Prime Real Estate" being low level water front with the Seattle skyline and surrounding area views. The closeness of neighbors and the level of lower end housing in the area may depreciate it's value slightly.



- Multiple problems have caused failure of the wrap around deck and hot tub platform. Mainly due to poor structural construction and thereafter rain water and plumbing water penetration and degeneration of timbers and decking.



- The wrap around deck was then also enclosed to form storage areas and again various problems including poor construction and general lack of TLC have left an open and poor shell to work with.

- What looks to have taken place at the front of the house is that a double tiered external deck has been used to extend the house walls and then enclosed to form two sun rooms. The deck then has been extended to form a wrap around with a section for a hot tub.

- Various siding defects are present on the main structure and on the lower storage area.

- On the south side of the house a breakfast nook has been extended out and is supported on a treated beam with piers and posts. Vegetation is covering these posts which needs to be cut back to ensure against any possible rot that may be occurring. Support off the house should also be examined and if necessary repairs should be carried out.

- The foundation of the building looks to be intact but only a partial external viewing could be seen and therefore further in depth inspections would need to be carried out to be totally satisfied. This can be better achieved after the basement has been gutted etc.

- At the rear an entrance has been covered and looks to have been built over the basement entrance and the retaining wall has been used for a foundation. Again some clearing and cleaning is required to examine these walls for structural stability.

- The first course of action in a project of this scale is to define a time scale for work with budget allowances. A minimum of 6 months and a sum of $75,000.00 is suggested as a starting point. This could be doubled and anything in between may occur, depending upon the actual extent and finish of the work required.





- The garage requires an extensive evaluation to render structural issues occurring. The western elevation supporting wall is inclined due to ground movement of the retaining wall foundation.

- The roof was not accessed due to height but does not look to be that old.

- One or more circuit breakers are "double tapped", (in the basement panel), where 2 or more wires are clamped in a circuit breaker terminal, and the circuit breaker is only designed for 1 wire. This is a safety hazard since wires may come loose and cause arcing, sparking and fires.


- This home has solid-strand branch circuit aluminum wiring. This type of aluminum wiring is a potential fire hazard. Problems due to expansion and contraction can cause overheating at connections between the wire and devices such as switches and outlets, or at splices. The Consumer Products Safety Commission recommends either discontinuing use of circuits with aluminum wiring, or pigtailing copper wiring onto the ends of the aluminum wire. Recommend having a qualified electrician evaluate and repair or replace this wiring.

- Due to the poor electrical installation recommend that a rip out and re-installation occur.
- The estimated useful life for water heaters is 8-12 years. This water heater appears to be at this age or older and may need replacing at any time.

- The house is only provided with a few heaters and much of the house heat was probably left to solar gain.
- The attic area was partially traversed and the under side of the roof was inspected.
- The washing machine point is on the upper level built into a small alcove. The clothes dryer point was not noted at this time.
- The plumbing service looks to be a minor mix of old and mainly all new within the last 10-20 years.



- The basement areas were noted to be contaminated with mold spores growing in various places. All seemed to be caused by basic deficiencies i.e. Ventilation and heating with an appropriate food source in the form of minor moisture problems.


- Once a complete strip out has occurred in the basement area a further evaluation can be made of any addition works required. 

- The upper level sun room has been poorly installed by someone "trying their hand at construction". The roof ceiling joists are nailed and pulling away from their ledger board.
- Overall all the interior rooms need some attention in one form or another with bathrooms probably in need of some updating replacement as does the kitchen but in general all could be worked with to help keep the financial costs down.