Website: http://SureLook-Homes.com
Email: fetterplace2486@charter.net
Phone: (360) 340-4555
PO Box 462 
Port Orchard, WA 98366
Inspector: Gary Fetterplace

 

Structural Pest & Home Inspection Report
Client(s): Gary Fetterplace
Property address: 2285 Evergreen Avenue SE
Port Orchard
98366
Inspection date: Saturday 27th March
This report published on 3/28/2004 12:00:45 PM PST

View summary page

Thank you for choosing SureLook Homes Inc for your structural pest & home inspection.

This report has been compiled for training purposes only and may not be used in any manner towards a real estate transaction or tenant/landlord dispute. It's content constitutes no contract between SureLook Homes Inc/Gary Fetterplace and any recipient and remains in sole ownership of the said company/inspector.


How to Read this Report
This report is organized by the property's functional areas. Within each functional area, descriptive information is listed first and shown in bold type. Items of concern follow descriptive information and are shown as follows:
SafetyPoses a risk of injury or death 
Major defectCorrection likely involves a significant expense 
Repair/ReplaceRecommend repairing or replacing 
Repair/MaintainRecommend repair and/or maintenance 
Minor defect 
MaintainRecommend ongoing maintenance 
EvaluateRecommend evaluation by a specialist 
MonitorRecommend monitoring in the future 
CommentFor your information 
Concern items are sorted by the types listed above. Click here for a glossary of building construction terms.

Structural Pest Inspection Concerns
Items marked with the following icons relate to the structural pest inspection
InfestationEvidence of infestation of wood destroying insects or organisms (Live or dead insect bodies, fungal growth, etc.)
DamageDamage caused by wood destroying insects or organisms (Rot, carpenter ant galleries, etc.)
Conducive
conditions
Conducive conditions for wood destroying insects or organisms. (Wood-soil contact, shrubs in contact with siding, roof or plumbing leaks, etc.)

 


General information
Overview: A Typical 3 Bedroom 1.5 bathroom Rambler style property on a good residential street.
Report number: 270304003
Time started: 10.15
Time finished: 13.30
Inspection Fee: Free Training Inspection
Present during inspection: Tenant
Occupied: Yes
Age of building: 1972
Type of building: Single family
Weather conditions: Clear
Temperature: Cool
Ground condition: Damp
Main entrance faces: West
Foundation type: Crawlspace
Comment   1) Numerous wall, floor and/or ceiling surfaces were obscured by large amounts of furniture and/or stored items, preventing a full evaluation of some areas.

 


Exterior
Footing material: Poured in place concrete
Foundation material: Poured in place concrete, Post and pier
Apparent wall structure: Wood frame
Wall covering: Wood clapboard
Driveway material: Asphalt
Sidewalk material: Poured in place concrete
Exterior door material: Solid core wood
Major defectEvaluateMonitor   2) Water staining is evident on exterior bathroom wall. Either from rain water penetration or the shower ceramic tiled wall.


Photo 16

 
 

Repair/Replace Wood destroying insect or organism conducive conditions 3) One or more crawl space vents are below grade with inadequate wells. Recommend repairing or replacing inadequate wells to prevent rainwater from entering vents and to eliminate earth/wood contact.


Photo 8

 
 

Repair/Replace   4) Recommend patching cracks and/or holes in asphalt driveway where necessary.
Repair/MaintainEvaluate   5) Moderate cracks (1/8" to 3/4") present in foundation. These may be a structural concern and the client may wish to hire a geotechnical engineer to evaluate possible soil movement and/or a structural engineer to evaluate the integrity of the structure. At a minimum, recommend sealing cracks to prevent water infiltration. Numerous products exist to seal such cracks including:
  • Hydraulic cement. Requires chiseling a channel in the crack to apply. See http://www.quickrete.com/catalog/HydraulicWater-StopCement.html for an example.
  • Resiliant caulks (easy to apply). See http://www.quickrete.com/catalog/GrayConcreteRepair.html for an example.
  • Epoxy sealants (both a waterproof and structural repair). See http://www.mountaingrout.com/ for examples of these products.


    Photo 11

     
     

  • Repair/Maintain Wood destroying insect or organism conducive conditions 6) Soil is in contact with or less than 6" from siding and/or trim. Recommend grading soil so there's at least 6" of space between the siding and trim and the soil below.
    Repair/Maintain Wood destroying insect or organism conducive conditions 7) Shrub(s) in contact with siding. Recommend pruning or moving shrub(s) so there's at least a one foot gap between shrub(s) and siding. This gap should exist to allow siding and trim materials to dry quickly after it rains, and to eliminate pathways to the structure for wood destroying insects.
    Repair/Maintain   8) The garage door was noted to have a broken dent. The framing on one side has contact with the soil. Some minor rotting noted.

    A gas valve has been plugged off at the front of the house. Recommend handle is completely removed.


    Photo 12

     
     

    EvaluateMonitor   9) It was noted that the front sitting room window is slightly bowed.


    Photo 5

     
     

    Comment   10) Minor cracks in sidewalk. These are only a cosmetic concern. No action is recommended.

     


    Roof
    Roof inspection method: Traversed
    Roof type: Gable
    Roof covering: Asphalt or fiberglass composition shingles
    Estimated age of roof: 10-15 Years
    Gutter & downspout material: Galvanized steel
    Roof ventilation: Adequate
    Repair/ReplaceMaintainMonitor Wood destroying insect or organism conducive conditions 11) The chimney is wider than 2' and no "cricket" (a small ridged roof section just above the chimney to shed water off to the sides) is installed above the chimney. Organic debris from trees may accumulate here and cause leaks. Recommend monitoring this area for accumulated debris and cleaning when necessary. Recommend installing a cricket when next roof is installed.


    Photo 7

     
     

    Repair/ReplaceEvaluate   12) Rain water caps not installed over chimney. Recommend installation of same.
    Repair/ReplaceEvaluate   13) A minor amount Masonry chimney mortar is deteriorated which requires repointing.
    Repair/MaintainEvaluateMonitor Wood destroying insect or organism conducive conditions 14) Recommend cleaning gutters only minor debris noted in uneven spots. Gutters need some realignment in these areas.


    Photo 2

     
     

    Repair/MaintainMonitor   15) Some rotting of the roof line structure tips was noted.


    Photo 15

     
     

    Repair/Maintain Wood destroying insect or organism conducive conditions 16) A minor amount of Moss is growing on the roof. This can lead to the premature failure of the roof and subsequent leaks. Recommend treating moss during its growing season (wet months) with a moss killer. For information on various moss treatment products and their pros and cons, visit http://bryophytes.science.oregonstate.edu/page24.htm
    Repair/Maintain   17) This stainless steel chimney could do with some caulking around flashing to prevent any water ingress.


    Photo 10

     
     

     


    Attached garage
    SafetyRepair/ReplaceEvaluate   18) One or more hot-neutral reversed outlets. One or more outlets require re-fixing. One or more lights require refixing.

    No Outlets were GFI protected.
    Repair/ReplaceComment   19) Dryer vent hose had come adrift due to bedding placed over it. Requires reinstalling. Dryer fluff debris noted in and around dryer. Recommend clearing/cleaning/vacuuming
    Repair/MaintainComment   20) Evidence of spider infestation. Recommend clearing, cleaning and vacuuming.

    Large amounts of stored garbage in garage!
    Monitor   21) Old water staining around chimney from rain penetration.


    Photo 6

     
     

     


    Electric service
    Primary service type: Underground
    Primary service overload protection type: Circuit breakers
    Service amperage (amps): 200
    Service voltage (volts): 120-240
    Location of main service panel: Garage wall
    Location of main disconnect: No single main disconnect, use all breakers in main panel
    Service conductor material: Aluminum
    Main disconnect rating (amps): Not applicable, no single main disconnect
    Branch circuit wiring type: Non-metallic sheathed
    Smoke detectors present: Yes
    Repair/MaintainEvaluateComment   22) No GFI or AFI circuit breakers are present and the loading particularly from the kitchen area would benefit from an additional branch circuit.


    Photo 9

     
     

    Repair/MaintainEvaluate   23) One outlet in bedroom 3 is not functional and requires investigation/repair by a qualified electrician.

     


    Water heater
    Estimated age: 5-10 years
    Type: Tank
    Energy source: Electricity
    Capacity (in gallons): 40
    Major defectRepair/Replace   24) The estimated useful life for water heaters is 8 to 12 years. This water heater may need replacing at some time in the near future.

     


    Heating and air conditioning
    Heating system energy source: Natural gas
    Heat system type: Forced air
    Distribution system: Sheet metal ducts
    Location of filter(s): Return Air Duct
    MaintainMonitor   25) This system is equipped with washable filter(s). They appear to be dirty. Recommend washing filter(s) now and every 2 months in the future if the thermostat's fan position is set to "Auto", or monthly if it's set to "On".
    Maintain   26) Recommend that this system be inspected & serviced as necessary by a qualified heating and cooling technician.

     


    Attic
    Inspection method: Traversed
    Roof structure type: Trusses
    Insulation material: Fiberglass loose fill
    Insulation depth: 6 Inches
    Insulation estimated R value: R19
    Repair/ReplaceEvaluate   27) Gas pipework near chimney has surface rust due to previous roof/chimney leaks. Recommend cleaning/painting or replacing if necessary.


    Photo 19

     
     

    Repair/Replace   28) Insulation is missing or uneven in some areas. Recommend installing additional insulation where necessary.
        29) Access in the attic is precarious due to the ac duct. A return visit to conclude this inspection is required.


    Photo 4

     
     

     


    Plumbing and laundry
    Location of main water shut-off valve: To be determined
    Location of main water meter: Front Garden Start reading063977 finish 063984
    Water service: Public
    Service pipe material: Copper
    Vent pipe material: Plastic
    Drain pipe material: Plastic
    Waste pipe material: Plastic
    Repair/MaintainMonitor   30) The toilet cisterns have had past problems with their flapper valves sticking and causing overflow water. These require replacing.

     


    Fireplaces and solid fuel burning appliances
    Fireplace type: Masonry
    Chimney type: Masonry
    SafetyMajor defect   31) The damper handle was found to be missing and can only be operated by hand/fire poker! Prior to the next heating season a qualified chimney expert should evaluate and repair hearth brickwork and fixtures before any use.

     


    Crawl space
    Inspection method: Traversed
    Insulation material underneath floor above: Fiberglass roll or batt
    Pier or support post material: Concrete
    Beam material: Solid wood
    Floor structure above: Solid wood joists
    Vapor barrier present: Yes
    Major defectEvaluateMonitor Wood destroying insect or organism conducive conditions 32) Evidence of water leakage from either the shower/bathroom ceramic tiled wall or penetrated rain water. The sill plate in this area is black with mold and sodden. Recommend investigation to identify leak, repair and replace as necessary.


    Photo 18

     
     

    Major defectEvaluate   33) Previous bathroom leakage is evident on old substructure i.e. some wood rot and staining. New sub structure flooring was poorly installed and does not sit on the sill plate. Recommend evaluation and repair.


    Photo 17

     
     

    Repair/Replace Wood destroying insect or organism conducive conditions 34) Paper or cardboard forms have been left on the concrete pier footings. Recommend removing these to avoid attracting wood destroying insects.
    Repair/Replace Wood destroying insect or organism conducive conditions 35) The master bedroom bathroom air duct has dropped off and requires refixing.


    Photo 13

     
     

    Repair/Replace   36) Some insulation in the crawlspace has fallen down. Recommend reinstalling or replacing this insulation. to provide fall access around the crawlspace.
    Minor defect Wood destroying insect or organism conducive conditions 37) One or more crawl space vents are blocked by floor insulation. Recommend trimming or removing insulation as necessary so all vents are unobstructed and to allow adequate ventilation.
    Minor defect Wood destroying insect or organism conducive conditions 38) Wood scraps and various debris found in crawl space. Recommend removing to avoid attracting wood destroying insects.


    Photo 14

     
     

    Comment   39) On completion of crawlspace works the WDO's inspection can be completed.

     


    Interior rooms
    SafetyRepair/Replace   40) No ground fault circuit interrupter (GFCI) outlets installed. GFCI outlets help prevent electric shocks in areas that may have water present. Recommend having a qualified electrician install one or more GFCI outlets, especially over counter tops and around sinks.
    Repair/Maintain   41) Front screen door handle is broken and requires repair/replacement.
    MaintainEvaluateMonitor   42) Water leakage under the refrigerator was noted. The floor had some stains. Recommend pulling unit out, cleaning and evaluate if leak is from defrost/ via seal or else where. Repair replace as necessary.
    Maintain   43) The main bathroom extract fan was noted to be clogged with fluff and requires cleaning to ensure moisture extraction. The caulking around the tub was noted to have some mold growth which requires cleaning.

    The master bedroom bathroom was noted to have cobwebs and requires cleaning as necessary.
    Maintain   44) The rear family/lounge room carpet was noted to have some staining and requires cleaning as necessary.


    Photo 3

     
     


    Your default report footer here...
    Powered by ReportHostThis report was published with ReportHost, the premier web-based inspection report writing service. For more information visit http://www.reporthost.com