StepByStep Home Services LC Home Inspection Report |
| Client(s): |
xxxxxxxxx |
| Property address: |
xxxxxxx xxxxxx, MI |
| Inspection date: |
Thursday, May 31, 2007 |
This report published on 4/16/2008 6:35:44 PM EDT
Duty to the Public
1. The NACHI Inspector shall abide by the Code of Ethics and substantially follow the NACHI Standards of Practice.
2. The NACHI inspector will not engage in any practices that could be damaging to the public or bring discredit to the home inspection industry.
3. The NACHI Inspector shall be fair, honest, impartial, and act in good faith in dealing with the public.
4. The NACHI Inspector will not discriminate in any business activities on the basis of race, color, religion, sex, national origin, familial status, sexual orientation, or handicap and shall comply with all federal, state and local laws concerning discrimination.
5. The NACHI Inspector shall be truthful regarding his/her services & qualifications.
6. The NACHI Inspector will have no undisclosed conflict of interest with the client, nor will the NACHI Inspector accept or offer any undisclosed commissions, rebates, profits, or other benefit.
7. The NACHI Inspector shall always act in the interest of the client, unless doing so violates a law, statute, or this Code of Ethics.
8. The NACHI Inspector shall use a written contract that specifies the services to be performed, limitations of services, and fees.
9. The NACHI Inspector shall comply with all government rules and licensing requirements of the jurisdiction where he/she conduct business.
10. The NACHI Inspector shall not offer to perform repairs on the property that was inspected for a period of 12-months from the time of the initial inspection.
Duty to Continue Education
1. The NACHI Inspector will comply with NACHI's current Continuing Education Requirements.
2. The NACHI Inspector shall pass the NACHI's Online Inspector Exam once every calendar year.
Duty to the Profession and NACHI
1. The NACHI Inspector will strive to improve the Home Inspection Industry by sharing his/her lessons and/or experiences for the benefit of all. This does not preclude the Inspector from copyrighting or marketing his/her expertise to other Inspectors or the public in any manner permitted by law.
2. The NACHI Inspector shall assist the NACHI leadership in disseminating and publicizing the benefits of NACHI membership.
3. The NACHI Inspector will not engage in any act or practice that could be deemed damaging, seditious, or destructive to NACHI, fellow NACHI members, NACHI employees, leadership or directors. Member(s) accused of acting or deemed in violation of such rules shall be reviewed by the Ethics committee for possible sanctions and/or expulsion from NACHI.
How to Read this Report
This report is organized by the property's functional areas. Within each functional area, descriptive information is listed first and is shown in bold type. Items of concern follow descriptive information.
Concerns are shown and sorted according to these types: | Safety | Poses a risk of injury or death |
 | Major Defect | Correction likely involves a significant expense |
 | Repair/Replace | Recommend repairing or replacing |
 | Repair/Maintain | Recommend repair and/or maintenance |
 | Minor Defect | Correction likely involves only a minor expense |
 | Maintain | Recommend ongoing maintenance |
 | Evaluate | Recommend evaluation by a specialist |
 | Monitor | Recommend monitoring in the future |
 | Comment | For your information |
Click here for a glossary of building construction terms.
Contact your inspector if there are terms that you do not understand, or visit the glossary of construction terms at http://www.reporthost.com/glossary.asp
Table of Contents
General Information
Exterior
Roof
Garage
Electric Service
Water Heater
Heating
Cooling
Plumbing and Laundry
Fireplaces, woodstoves and chimneys
Kitchen
Breakfast Nook
Living Room
Interior Rooms
Master Bathroom
Bedroom 3
Bathroom 1 Off Laundry
Bathroom 2 Upstairs
Basement
Attic
Crawl Space
Report number: 53107
Structures inspected: Home/Garage
Type of building: Single family
Age of building: 1964
Property owner's name:
Report number: 53106
Structures inspected: Home/Garage
Type of building: Single family
Age of building: 1964
Property owner's name: Unknown
Time started: 12:00
Time finished: 6:00
Inspection Fee: 379.00
Payment method: Check
Present during inspection: Client(s), Realtor(s)
Occupied: No
Weather conditions: Clear
Temperature: Hot
Ground condition: Dry
Foundation type: Unfinished basement, Finished basement, Crawlspace
The following items are excluded from this inspection: Items listed in the NACHI SOP as outside the scope of the home inspections.
1)


One or more leaks were found in gas supply lines, fittings and/or valves at the hot water heater. This is a safety hazard due to the risk of explosion. A qualified contractor and/or the gas utility company should evaluate and make repairs as soon as possible. I turned the gas off at the exterior of the home.

Photo 73
|

Photo 74
|
2)

Structures built prior to 1979 may contain lead-based paint and/or asbestos in various building materials such as insulation, siding, and/or floor and ceiling tiles. Both lead and asbestos are known health hazards. Evaluating for the presence of lead and/or asbestos is not included in this inspection. The client(s) should consult with specialists as necessary, such as industrial hygienists, professional labs and/or abatement contractors for this type of evaluation. For information on lead, asbestos and other hazardous materials in homes, visit these websites:
The Environmental Protection Association (http://www.epa.gov)
The Consumer Products Safety Commission (http://www.cpsc.gov)
The Center for Disease Control (http://www.cdc.gov)
Foundation material: Poured in place concrete
Apparent wall structure: Wood frame
Wall covering: Brick veneer, Vinyl
Driveway material: Poured in place concrete
Sidewalk material: Brick
Exterior door material: Solid core steel
3)


One or more trip hazards were found in the driveway due to cracks, settlement and/or heaving. Recommend having a qualified contractor evaluate and repair or replace driveway sections as necessary to eliminate trip hazards.

Photo 2
|
|
4)

One or more wall-mounted exterior light fixtures have wiring that's subject to water intrusion due to caulk not being installed around the light fixture's back plate. Caulk should be applied around the perimeter of back plates where missing. A gap should be left at the bottom for condensation to drain out.

Photo 6
|
|
5)

One or more hornet, bee and/or wasp nests were found. These can pose a safety hazard. Nest(s) should be removed as necessary.

Photo 4
|
|
6)

The drain tile at the exterior downspout of sump drain is crushed and no longer functional. Recommend repairs by a licensed contractor.

Photo 102
|
|
7)

Moderate cracks and/or deterioration found in one or more sections of brick veneer. A qualified contractor should evaluate and make repairs as necessary, such as repointing mortar, replacing bricks and/or sections of veneer.
The brick in several areas is below grade where the soil and mulch is covering the bricks. This condition will cause the mortar and bricks to deteriorate. Recommend removing mulch and soil from those areas while being sure to maintain a proper slope away from the home. Several areas of brick that were not visible at the time of the inspection may need to be replaced once the soil and mulch is removed revealing the bricks.

Photo 17
|

Photo 18
|
8)


Minor cracks were found in one or more sections of brick veneer. A qualified contractor should evaluate and make repairs as necessary, such as repointing mortar to prevent water intrusion and further deterioration in the future.
Photos taken at the right side of the home off the garage.

Photo 22
|

Photo 23
|
9)
The perimeter grading slopes towards the structure in one or more areas. This can result in water accumulating around the structure's foundation, or in basements and crawl spaces if they exist. Accumulated water is a conducive condition to wood destroying insects and organisms. Wet soil may also cause the foundation to settle and possibly fail over time. Recommend grading soil so it slopes down and away from the structure with a slope of at least 5% (10% or better is optimal) for at least 6 feet.

Photo 8
|

Photo 9
|

Photo 12
|

Photo 13
|
10)
A shutter at the front of the home is loose where the fastener is not long enough to attach it to the brick. Recommend installing a longer fastener or using an epoxy to attach the shutter to the wall. These gaps are typical areas for bees or hornets nests.

Photo 7
|
|
11)
An outside faucet handle at the rear of the home is not properly attached. Recommend installing a new handle to allow for proper function.

Photo 11
|
|
12)
One or more downspouts are dented, damaged and/or crushed. This can restrict the water flow and result in clogging and overflowing gutters. Water may accumulate around the structure's foundation, or in basements and crawl spaces if they exist. Accumulated water is a conducive condition to wood destroying insects and organisms, and may also cause the foundation to settle and possibly fail over time. Damaged downspouts should be repaired or replaced as necessary, and by a qualified contractor if necessary.

Photo 14
|
|
13)

The front porch is cracked and should be patched with cement or hydraulic cement to prevent further deterioration. This crack does not present a trip hazard.

Photo 3
|
|
14)
Vegetation such as trees, shrubs and/or vines are in contact with or less than one foot from the structure's exterior. Vegetation can serve as a conduit for wood destroying insects and may retain moisture against the exterior after it rains. Vegetation should be pruned and/or removed as necessary to maintain a one foot clearance between it and the structure's exterior.

Photo 10
|

Photo 19
|

Photo 20
|

Photo 21
|

Photo 25
|
|
15)
Window glazing putty at one or more windows is missing and/or deteriorated. Putty should be replaced and/or installed where necessary. For more information on replacing window putty, visit: http://www.oldhouseweb.com/stories/Detailed/12216.shtml

Photo 5
|
|
16)
Several areas at the right side of the home has what appears to be a type of fungus growing on it. Recommend using a siding cleaner such as Siding OX and stiff brush available at your local hardware store.
http://www.cleanertoday.com/Vinyl_Siding_cleaner_Quick_Simple_Effective_s/7.htm

Photo 24
|

Photo 35
|

Photo 36
|

Photo 37
|
Roof inspection method: Traversed
Roof type: Gable
Roof covering: Asphalt or fiberglass composition shingles
Estimated age of roof: 6 Years over garage / 8 years over the home
Gutter & downspout material: Aluminum
Roof ventilation: Inadequate
17)

A section of the roof near the chimney dips and may prevent water from shedding off the surface. Recommend repairs such as replacing sheathing to allow for a proper slope and water flow.

Photo 32
|

Photo 34
|
18)

A downspout over the garage terminates directly on the surface. This can cause the shingles in this area to deteriorate quickly by washing the granuals off the shingles. Recommend extending the downspout to the gutter below.

Photo 31
|
|
19)


One or more open ground, three-pronged electric receptacles were found. This is a safety hazard due to the risk of shock. A qualified electrician should evaluate and make repairs as necessary. For example, replacing receptacles or correcting wiring circuits.
Grounding type receptacles began being required in residential structures during the 1960s. Based on the age of this structure and the presence of 2-pronged receptacles in some areas of this structure, an acceptable repair may be to simply replace the ungrounded 3-pronged receptacles with 2-pronged receptacles. However the following appliances require grounding type receptacles:
Computer hardware
Refrigerators
Freezers
Air conditioners
Clothes washers
Clothes dryers
Dishwashers
Kitchen food waste disposers
Information technology equipment
Sump pumps
Electrical aquarium equipment
Hand-held motor-operated tools
Stationary and fixed motor-operated tools
Light industrial motor-operated tools
Hedge clippers
Lawn mowers
This list is not exhaustive. Grounded circuits and receptacles should be installed in locations where such appliances will be used.

Photo 27
|
|
20)


Minor cracks were seen at the garage slap. Recommend sealing cracks with concrete of hydraulic cement.

Photo 26
|
|
21)
Hardware that fastens the garage door opener to the roof structure is missing a bolt. Recommend installing a bolt where is is connected to the truss bottom cord.

Photo 28
|
|
Primary service type: Underground
Primary service overload protection type: Circuit breakers
Service amperage (amps): 200
Service voltage (volts): 120/240
Location of main service switch: Basement
Location of main disconnect: Breaker at top of main service panel
System ground: Cold water supply pipes
Main disconnect rating (amps): 200
Branch circuit wiring type: Non-metallic sheathed
Solid strand aluminum branch circuit wiring present: No
Smoke detectors present: Yes Recommend installing smoke and CO detectors in each bedroom.
22)

Conductors that are connected to circuits should be marked black or red to identify them as hot conductors. This photo shows a white (typically neutral) conductor conned directly to a circuit. Recommend marking conductor with red or black marker or tape.

Photo 72
|
|
23)

Insulation on conductors should not extend more than one inch into the main panel. Recommend removing insulation so that is does not extend too far into the panel.

Photo 71
|
|
Estimated age: 1995
Type: Tank
Energy source: Natural gas
Capacity (in gallons): 76
Manufacturer: A.O. Smith
Model: FXG
Water temperature (degrees Fahrenheit): 160 - taken at an upstairs bathroom.
24)

The estimated useful life for most water heaters is 8 to 12 years. This water heater appears to be at this age or older and may need replacing at any time. Recommend budgeting for a replacement in the near future.
25)

Corrosion was found in one or more areas on the water heater where the dielectric union is damaged or installed improperly. Recommend repairs to prevent further corrosion and possible water leaks.

Photo 75
|
|
Estimated age: 1993
Primary heating system energy source: Natural gas
Primary heat system type: Forced air
Distribution system: Sheet metal ducts
Manufacturer: Carrier
Model: WEATHERMAKER 8000
Filter location: In return air duct below furnace
26)

The estimated useful life for most forced air furnaces is 15 to 20 years. This furnace appears to be approaching this age and may need replacing at any time. Recommend budgeting for a replacement in the near future.
27)

Air handler filter(s) is damaged and should be replaced now. This type of filter generally lasts up to 10 months. Recommend checking the filter every three months and replacing when excessively dirty in the future.

Photo 76
|
|
28)

The last service date of this system appears to be more than one year ago, or the inspector was unable to determine the last service date. The client(s) should ask the property owner(s) when it was last serviced. If unable to determine the last service date, or if this system was serviced more than one year ago, a qualified heating and cooling contractor should inspect, clean, and service this system, and make repairs if necessary. This servicing should be performed annually in the future.
29)
Because of the excessive gas leak at the hot water heater I was unable to test the furnace flames. The furnace heating was not evaluated.
Estimated age: 2002
Primary A/C energy source: Electric
Primary Air conditioning type: Split system
Distribution system: Sheet metal ducts
Manufacturer: Tech 2000
Model: Silencer System
30)
Vegetation such as trees, shrubs and/or vines are too close to the outdoor condensing unit. Standard building practices require that there be at least 12 inches of clearance on all sides and at least four to six feet above. Inadequate clearances around the condensing unit can result in reduced efficiency, increased energy costs and/or damage to equipment. Vegetation should be pruned and/or removed as necessary to maintain these clearances.

Photo 16
|
|
Water pressure (psi): 82
Location of main water shut-off valve: Basement
Location of main water meter: Basmement
Location of main fuel shut-off: Exterior Left
Water service: Public
Service pipe material: Copper
Supply pipe material: Copper
Vent pipe material: Cast iron
Drain pipe material: Plastic
Waste pipe material: Plastic, Cast iron
31)

The clothes dryer is equipped with a vinyl or foil, accordion-type, flexible exhaust duct. The U.S. Consumer Product Safety Commission considers these types of ducts to be unsafe, and a fire hazard. These types of ducts can trap lint and are susceptible to kinks or crushing, which can greatly reduce the air flow. This duct should be replaced with a rigid or corrugated semi-rigid metal duct, and by a qualified contractor if necessary. Most clothes dryer manufacturers specify the use of a rigid or corrugated semi-rigid metal duct. For more information on dryer safety issues, see http://www.cpsc.gov/CPSCPUB/PUBS/5022.html

Photo 55
|
|
32)
The water supply pressure is greater than 80 psi. Pressures above 80 psi may void warranties for some appliances such as water heaters or washing machines. Flexible supply lines to washing machines are more likely to burst with higher pressures. Typically the pressure cannot be regulated at the water meter. Recommend having a qualified plumber evaluate and make modifications to reduce the pressure below 80 psi. Installing a pressure reducing valve on the main service pipe is a common solution to this problem. If one exists, then it should be adjusted for lower pressures.
Water pressure taken at the exterior left and was at 83 psi.

Photo 77
|
|
Fireplace type: Masonry
Chimney type: Masonry
33)


A significant amount of creosote (1/8 inch or more) is visible in the fireplace flue. A qualified chimney service contractor should clean now and annually in the future.

Photo 50
|

Photo 51
|

Photo 52
|

Photo 53
|
34)

The fireplace doors are loose where a bolt is either not properly secured or stripped. Recommend repairs to allow for proper function.

Photo 54
|
|
35)

The masonry chimney's mortar is deteriorated and should be repaired to prevent further, significant deterioration. Recommend having a qualified chimney service contractor or mason evaluate chimney and repair as necessary. This will likely require repointing the mortar.

Photo 38
|

Photo 39
|
36)
Flashing at the base of the chimney is not in contact with the brick causing a gap. Recommend repairs such as adding caulk to prevent water from entering the attic area.

Photo 33
|
|
37)

The range can tip forward, and no anti-tip bracket appears to be installed. This is a safety hazard since the range may tip forward when weight is applied to the open door, such as when a small child climbs on it, or if heavy objects are dropped on it. Anti-tip brackets have been sold with all free standing ranges since 1985. An anti-tip bracket should be installed to eliminate this safety hazard. For more information, visit http://www.hgtv.com/hgtv/remodeling/article/0,1797,HGTV_3659_2017492,00.html
38)

The bottom door on the range is loose where the hardware is loose or bent. Recommend repairs such as bending hardware back into place or replacing.

Photo 45
|
|
39)

The dishwasher drain line is not configured with a "high loop" or "air gap". A high loop is created by routing the drain line up to the bottom surface of the counter top above, and securely fastening it to that surface. It is meant to prevent water from siphoning out of the dishwasher, and to prevent water from the sink drain or food disposal from entering the dishwasher. Some dishwashers have a built-in high loop where one is not required to be configured in the drain line. The clients should try to determine if a high loop is required for this brand and model of dishwasher (review installation instructions, etc.). If one is required, or it cannot be determined if one is not required, then a qualified contractor should install a high loop as per standard building practices.
Also, no "air gap" is installed. Air gaps are another device meant to prevent water from the sink drain or food disposal from entering the dishwasher. These are required in some municipalities for new construction and when remodeling. The client(s) should consult with a qualified contractor to determine if an air gap should be installed.

Photo 40
|
|
40)

The window in front of the sink does not open all the way and catches on the overhang flashing at the exterior. Recommend repairing the flashing to allow for proper function.

Photo 42
|

Photo 43
|
41)
Hardware such as hinges, latches or pulls are loose and/or missing on one or more cabinets. Repairs should be made and/or hardware should be replaced as necessary, and by a qualified contractor if necessary.

Photo 41
|
|
42)
Caulk is missing and/or deteriorated where countertops meet backsplashes in wet areas, such as around sinks. Caulk should be replaced where deteriorated and/or applied where missing to prevent water damage.

Photo 44
|
|
43)

Evidence of a past water leak was seen at the ceiling. This area was tested with a Wagner MMC moisture meter and was dry at the time of the inspection.

Photo 48
|
|
44)
One or more doors will not latch when closed. Repairs should be made as necessary, and by a qualified contractor if necessary. For example, aligning strike plates with latch bolts and/or replacing locksets or adjusting hinges.

Photo 46
|

Photo 47
|
45)
Lock mechanisms on one or more windows or patio doors are missing and/or damaged so that they are inoperable or loose. Repairs should be made by a qualified contractor or service technician so that windows lock and unlock easily.

Photo 49
|
|
46)


Two-pronged electric receptacles rather than three-pronged, grounded receptacles are installed in one or more interior rooms. They are considered to be unsafe by today's standards and limit the ability to use appliances that require a ground in these rooms. Examples of appliances that require grounded receptacles include:
Computer hardware
Refrigerators
Freezers
Air conditioners
Clothes washers
Clothes dryers
Dishwashers
Kitchen food waste disposers
Information technology equipment
Sump pumps
Electrical aquarium equipment
Hand-held motor-operated tools
Stationary and fixed motor-operated tools
Light industrial motor-operated tools
Hedge clippers
Lawn mowers
This list is not exhaustive. A qualified electrician should evaluate and install grounded receptacles as per the client(s)' needs and standard building practices.
47)

Hardware such as hinges, latches or pulls are loose and/or missing on one or more cabinets. Repairs should be made and/or hardware should be replaced as necessary, and by a qualified contractor if necessary.
Photo taken in the laundry room.

Photo 56
|
|
48)

One or more light fixtures are damaged and/or deteriorated. A qualified electrician should evaluate and repair or replace light fixtures where necessary.
Photo taken in the laundry room.

Photo 59
|
|
49)
One or more windows that were built to open, will not open, or open only minimally due to their being painted shut, damaged and/or deteriorated in some way. Repairs should be made as necessary, and by a qualified contractor if necessary so windows open fully, and open and close easily.
Photo taken in the laundry room.

Photo 57
|
|
50)
Glass in one or more windows is broken. A qualified contractor should replace glass where necessary.
Photo taken in the laundry room.

Photo 58
|
|
51)
Minor cracks were found in walls in one or more areas. They do not appear to be a structural concern, but the client(s) may wish to repair these for aesthetic reasons.
52)


One or more light fixtures are loose or installed in a substandard way. A qualified contractor or electrician should evaluate and make repairs as necessary so light fixtures are securely mounted and installed in accordance with the manufacturer's installation instructions.
The conductors sparked when the fixture was moved so I turned tripped the circuit in the basement. Recommend repairs such as replacing the conductors where damaged.

Photo 93
|
|
53)

Grout around the shower floor/wall is damaged or deteriorated.Recommend repairs such as applying caulk to prevent water from entering behind the shower pan and deteriorating the flooring.

Photo 61
|

Photo 62
|
54)
One or more bathrooms with a shower do not have an exhaust fan installed. Moisture accumulation will occur and may damage the structure. Even if the bathroom has a window that opens, it likely does not provide adequate ventilation, especially during cold weather when the window is closed. A qualified contractor should install exhaust fans as per standard building practices where missing in bathrooms with showers.
55)

The cover plate is missing where cable enters this room. Recommend installing a proper cable plate.

Photo 65
|
|
56)

Grout is cracked on the tiles near the toilet. Recommend repairs such as regrouting tiles to prevent water entry.

Photo 60
|
|
57)

Caulk is missing or deteriorated along the hot and cold water fixtures. Recommend applying caulk to prevent water entry.

Photo 64
|
|
58)
One or more bathrooms with a shower do not have an exhaust fan installed. Moisture accumulation will occur and may damage the structure. Even if the bathroom has a window that opens, it likely does not provide adequate ventilation, especially during cold weather when the window is closed. A qualified contractor should install exhaust fans as per standard building practices where missing in bathrooms with showers.
59)
The bathtub drain does not prevent the water from draining when in the up position. Recommend adjusting the drain for proper function.
http://www.homerepairforum.com/images/uploads/2005-8-28_Tub_Stopper_Linkage_w550.JPG
60)

The shower plate is not securely fasted to the wall and moves around when the shower valve is operated. Recommend repairs such as tightening the screw to allow for a firm attachment to the shower wall.

Photo 63
|
|
Insulation material underneath floor above: Fiberglass roll or batt
Pier or support post material: Steel
Beam material: Steel
Floor structure above: Solid wood joists
61)


An organic growth was seen at two areas of the basement. Recommend evaluation by a certified mold specialist to determine what type of growth it is and how to remove it.
Refer to my previous email for several contacts.

Photo 69
|

Photo 70
|
62)


Evidence of prior water intrusion was found in one or more sections of the basement. For example, water stains and/or efflorescence on the walls where rod holes are leaking. Accumulated water is a conducive condition for wood destroying insects and organisms and should not be present in the basement. The client(s) should review any disclosure statements available and ask the property owner(s) about past accumulation of water in the basement. The basement should be monitored in the future for accumulated water, especially after heavy and/or prolonged periods of rain. If water is found to accumulate, a qualified contractor who specializes in drainage issues should evaluate and repair as necessary. Typical repairs for preventing water from accumulating in the basement include:
Repairing, installing or improving rain run-off systems (gutters, downspouts and extensions or drain lines)
Improving perimeter grading
Repairing, installing or improving underground footing and/or curtain drains
Ideally, water should not enter the basement, but if water must be controlled after it enters the basement, then typical repairs include installing sump pump(s) or interior perimeter drains.

Photo 66
|

Photo 67
|

Photo 68
|
|
63)
The basement is partially finished preventing a full evaluation of those walls and ceiling areas obstructed by drop ceiling and panels.
Inspection method: Traversed
Roof structure type: Trusses
Ceiling structure: Trusses
Insulation material: Mineral wool roll or batt
Insulation depth: 7"
Insulation estimated R value: 19
64)


The roofs sheathing has a dip or sag over the garage and home. This can be the result of several things such as inadequate ventilation causing the sheathing to buckle, sheathing that is undersized for the truss span of 24" or sheathing that is installed without a proper gap or H clips. When the roof covering (shingles) are replaced I recommend the sheathing be replaced throughout to prevent this dip in the sheathing.
65)


Sheathing at the drip edge of the garage is rotten and not properly fastened to the roof causing an excessive dip where the roof is lower in the middle and high at the ends. Sheathing in this area should be replaces and properly fastened. Recommend evaluation and repairs by a licensed contractor.
66)


Most of the roofs sheathing is water damaged and buckles causing the roof to dip in several areas. Recommend repairs or replacement over the entire roof structure.
67)


Sheathing is damaged in the garage and home attic. Recommend replacement of damaged sheathing by a qualified contractor to prevent further damaged which may be caused by snow accumulation.
Some areas of the sheathing appear to have been replaced.

Photo 29
|

Photo 97
|

Photo 98
|

Photo 99
|
68)
The ceiling insulation's R rating is significantly less than what's recommended for this area. Recommend having a qualified contractor install additional insulation (three inches) as per standard building practices for better energy efficiency.

Photo 101
|
|
69)
One or more attic vents are blocked by insulation and/or debris. This can reduce air flow through the attic, reduce the life of the roof surface because of high temperatures, and/or increase moisture levels in the attic. Repairs should be made as necessary, such as moving insulation or debris, so vents are unobstructed.

Photo 95
|

Photo 96
|
70)

Stains were visible on the roof structure at the home and garage. These areas were dry at the time of the inspection. The stains may be caused by a past leak. Recommend asking the property owner(s) about past leaks. The client(s) should monitor these areas in the future, especially after heavy rains, to determine if active leaks exist. If leaks are found, a qualified roofing contractor should evaluate and repair as necessary.

Photo 30
|
|
71)
The roofs sheathing is missing H clips and does not have a gap between each panel. While H clips were not used in the 60's a gap should have been maintained to allow for expansion and contraction. When the roof sheathing is replaced H clips should be installed to allow for a proper gap and additional support.
Inspection method: Traversed
Insulation material underneath floor above: Foam
Pier or support post material: Steel
Beam material: Steel
Floor structure above: Solid wood joists
Vapor barrier present: Yes
72)

The crawlspace has a deep trench where the soil was not backfilled during construction. Backfilling allows for support to the basement walls and adds strength to the structure. Recommend adding soil and gravel to the area of the crawlspace that is not backfilled. A licensed contractor should perform this to ensure the soil is properly graded and gravel is added.

Photo 88
|

Photo 89
|

Photo 90
|
|
73)

Steel support posts are not securely fastened to the footing below. This is a safety hazard since they can separate during a seismic event. A qualified contractor should evaluate and make repairs as necessary, such as installing a properly sized support.

Photo 80
|

Photo 81
|
74)

Evidence of prior water intrusion was found in one or more sections of the crawl space substructure. These areas tested try at the time of the inspection however the floor structure is damaged or deteriorated and in need of replacement by a licensed contractor.

Photo 86
|

Photo 87
|
75)
The stove vent is excessively long and touching the crawl floor. This may cause the vent to deteriorate from moisture. Recommend trimming foil vent by a licensed contractor using proper connectors and clamps.

Photo 84
|
|
76)
One or more crawl space vent screens are blocked by soil, debris, insulation, stored items or removable panels. This restricts ventilation in the crawl space and may result in increased levels of moisture inside. Materials or items blocking vents should be removed.

Photo 82
|

Photo 83
|
77)
The vapor barrier needs repair. Exposed soil was found in some areas. This is a conducive condition for wood destroying insects and organisms due to the likelihood of water evaporating into the structure from the soil. A qualified contractor should make repairs as necessary so no exposed soil exists. Standard building practices require the following:
The soil below the vapor barrier should be smooth and free from sharp objects.
Seams should overlap a minimum of 12 inches.
The vapor barrier should lap up onto the foundation side walls.
Better building practices require that:
Seams and protrusions should be sealed with a pressure sensitive tape.
The vapor barrier should be caulked and attached tightly to the foundation side walls. For example, with furring strips and masonry nails.

Photo 78
|
|
78)
An opening was seen at the sump pump discharge line where it exits the home. Recommend sealing hole to prevent mice from entering the crawlspace.

Photo 91
|
|
79)
Insulation on air supply vents is deteriorated and/or missing in one or more areas. Recommend repairing or installing insulation on vent pipes where necessary for better energy efficiency.

Photo 79
|

Photo 85
|

Photo 92
|
|

Photo 15
|

Photo 94
|

Photo 100
|
|
The following contract is completed prior to the inspection.
www.stepbystepinspections.com
The address of the property is: ________________________________________________Fee for the home inspection is $____________________.
INSPECTOR acknowledges receiving a deposit of $_________________ from CLIENT.
THIS AGREEMENT made this _____________ day of _______________________________________________________, 200__, by and between
______________________________________________ (Hereinafter INSPECTOR) and the undersigned (hereinafter CLIENT), collectively referred to herein as the parties. The Parties Understand and Voluntarily Agree as follows:
1. INSPECTOR agrees to perform a visual inspection of the home/building and to provide CLIENT with a written inspection report identifying the defects that INSPECTOR both observed and deemed material. INSPECTOR may offer comments as a courtesy, but these comments will not comprise the bargained-for report. The report is only supplementary to the sellers disclosure.
2. Unless otherwise inconsistent with this Agreement or not possible, INSPECTOR agrees to perform the inspection in accordance to the current Standards of Practice of the National Association of Certified Home Inspectors posted at http://www.nachi.org/sop.htm. CLIENT understands that these standards contain certain limitations, exceptions, and exclusions.
3. The inspection and report is solely and exclusively for Clients own information and may not be relied upon by any other person. Client agrees to maintain the confidentially of the inspection report and agrees not to disclose any part of it to any other person. Client may distribute copies of the inspection report to the seller and the real estate agents directly involved in this transaction, but said persons are not specifically intended beneficiaries of this Agreement of the inspection report. Client and inspector do not in any way intend to benefit said seller or the real estate agents directly or indirectly through this Agreement or the Inspection report. Client agrees to indemnify, defend, and hold Inspector harmless from any third party claims arising out of Client?s unauthorized distribution of the inspection report.
4. INSPECTOR assumes no liability for the cost of repair or replacement of unreported defects or deficiencies either current or arising in the future. CLIENT acknowledges that the liability of INSPECTOR, its agents, employees, for claims or damages, costs of defense or suit, attorneys fees and expenses and payments arising out of or related to the INSPECTORS negligence or breach of any obligation under this Agreement, including errors and omissions in the inspection or the report, shall be limited to liquidated damages in an amount equal to the fee paid to the INSPECTOR, and this liability shall be exclusive. CLIENT waives any claim for consequential, exemplary, special or incidental damages or for the loss of the use of the home/building even if the CLIENT has been advised of the possibility of such damages. The parties acknowledge that the liquidated damages are not intended as a penalty but are intended (i) to reflect the fact that actual damages may be difficult and impractical to ascertain; (ii) to allocate risk among the INSPECTOR and CLIENT; and (iii) to enable the INSPECTOR to perform the inspection at the stated fee.
5. INSPECTOR does not perform engineering, architectural, plumbing, or any other job function requiring an occupational license in the jurisdiction where the inspection is taking place, unless the inspector holds a valid occupational license, in which case he/she may inform the CLIENT that he/she is so licensed, and is therefore qualified to go beyond this basic home inspection, and for additional fee, perform additional inspections beyond those within the scope of the basic home inspection. Any agreement for such additional inspections shall be in a separate writing or noted here: ______________________________________________________________________________________________________________________.
6. In the event of a claim against INSPECTOR, CLIENT agrees to supply INSPECTOR with the following: (1) Written notification of adverse conditions within 14 days of discovery, and (2) Access to the premises. Failure to comply with the above conditions will release INSPECTOR and its agents from any and all obligations or liability of any kind.
7. The parties agree that any litigation arising out of this Agreement shall be filed only in the Court having jurisdiction in the County in which the INSPECTOR has its principal place of business. In the event that CLIENT fails to prove any adverse claims against INSPECTOR in a court of law, CLIENT agrees to pay all legal costs, expenses and fees of INSPECTOR in defending said claims.
8. If any court declares any provision of this Agreement invalid or unenforceable, the remaining provisions will remain in effect. This Agreement represents the entire agreement between the parties. All prior communications are merged into this Agreement, and there are no terms or conditions other than those set forth herein. No statement or promise of INSPECTOR or its agents shall be binding unless reduced to writing and signed by INSPECTOR. No change or modification shall be enforceable against any party unless such change or modification is in writing and signed by the parties. This Agreement shall be binding upon and enforceable by the parties and their heirs, executors, administrators, successors and assignees. CLIENT shall have no cause of action against INSPECTOR after one year from the date of the inspection.
9. Payment of the fee to INSPECTOR (less any deposit noted above) is due upon completion of the on-site inspection. The CLIENT agrees to pay all legal and time expenses incurred in collecting due payments, including attorney?s fees, if any. If CLIENT is a corporation, LLC, or similar entity, the person signing this Agreement on behalf of such entity does personally guaranty payment of the fee by the entity.
CLIENT HAS CAREFULLY READ THE FOREGOING, AGREES TO IT, AND ACKNOWLEDGES RECEIPT OF A COPY OF THIS AGREEMENT.
____________________________ _________________________
FOR INSPECTOR CLIENT OR REPRESENTATIVE