Inspector: Josh Morrison
InterNACHI Certified #NACHI09083110

  

Property Inspection Report
Client(s): Mr. And Mrs. Smith
Property address: 1234 Anywhere St.
Clovis, CA 93611
Inspection date: Thursday, September 10, 2009
This report published on 9/30/2009 1:47:57 PM PDT

View summary page

This report is the exclusive property Star Energy Of Fresno and the client(s) listed in the report title. Use of this report by any unauthorized persons is prohibited.

 
How to Read this Report
This report is organized by the property's functional areas.  Within each functional area, descriptive information is listed first and is shown in bold type.  Items of concern follow descriptive information. Concerns are shown and sorted according to these types:
SafetyPoses a risk of injury or death 
Major DefectItem or component has one or more major flaws 
Repair/ReplaceRecommend repairing or replacing 
Repair/MaintainRecommend repair and/or maintenance 
Minor DefectItem has minor flaws that can likely be corrected. 
MaintainRecommend ongoing maintenance 
EvaluateRecommend evaluation by a specialist 
MonitorRecommend monitoring in the future 
ServiceableItem or component is in servicable condition 
CommentFor your information 

Structural Pest Inspection Concerns
Items of concern relating to the structural pest inspection are shown as follows:
WDO/WDI InfestationEvidence of infestation of wood destroying insects or organisms (Live or dead insect bodies, fungal growth, etc.) 
WDO/WDI DamageDamage caused by wood destroying insects or organisms (Rot, carpenter ant galleries, etc.) 
WDO/WDI Conducive
conditions
Conditions conducive for wood destroying insects or organisms (Wood-soil contact, shrubs in contact with siding, roof or plumbing leaks, etc.) 

Click here for a glossary of building construction terms.  Contact your inspector if there are terms that you do not understand, or visit the glossary of construction terms at http://www.reporthost.com/glossary.asp

Table of Contents
General information
Exterior
Roof
Garage
Attic
Electric service
Water heater
Heating and cooling
Plumbing and laundry
Fireplaces, woodstoves and chimneys
Kitchen
Bathrooms
Interior rooms

 
General information Return to table of contents
Report number: 09091001
Inspector's name: Josh Morrison
Type of building: Single family
Age of building: 24
Time started: 1215
Time finished: 1350
Inspection Fee: $350.00
Payment method: Cash
Present during inspection: Client(s), Property owner(s)
Occupied: Yes
Weather conditions: Clear
Temperature: Hot95
Ground condition: Dry
Front of structure faces: North
Main entrance faces: North
Foundation type: Slab on grade
General Site Grading: General grading is poor. Front of home needs additional drainage or relandscaping to keep water away from the structure.
The following items are excluded from this inspection: Swimming pool, Hot tub, Shed, Playground equipment
 
Exterior Return to table of contents
Footing material: Poured in place concrete
Foundation material: Poured in place concrete
Apparent wall structure: Wood frame
Wall covering: Brick veneer, Stucco
Driveway material: Poured in place concrete
Sidewalk material: Poured in place concrete
Exterior door material: Solid core wood
1)   Extension cords are being used as permanent wiring in one or more areas. They should only be used for portable equipment on a temporary basis. Using extension cords as permanent wiring poses a fire and shock hazard, and is an indication that wiring is inadequate and should be updated. Extension cords may be undersized. Connections may not be secure, resulting in power fluctuations, damage to equipment, and sparks that could start a fire. Extension cords should be removed as necessary, or a qualified electrician should evaluate and make repairs as necessary. For example, install additional circuits and/or electric receptacles.
2)   Waterproof cover(s) over one or more electric receptacles are damaged or broken. This is a safety hazard due to the risk of shock and fire. Damaged covers should be replaced where necessary.

Photo 9  
missing outdoor cover plate
 

3)   One or more exterior electric receptacles are being used for appliances or systems that are constantly in use, and are not equipped with a "while in use" receptacle covers for wet locations. This is a safety hazard due to the risk of shock and fire. "While in use" covers should be installed where necessary. For more information, visit:
http://www.google.com/search?q=while+in+use+receptacle+cover

4)   One or more outside faucets are missing backflow prevention devices. These devices reduce the likelihood of polluted or contaminated water entering the potable water supply. This condition can occur when an outside faucet is left in the "on" position with a hose connected and the sprayer head turned off. When pressure in the system fluctuates, water can be drawn back into the water supply pipes from the house. If a chemical sprayer is being used with the hose, those chemicals can enter the water supply pipes.

Recommend installing backflow prevention devices on all exterior hose bibs where missing. They are available at most home improvement stores and are easily installed. For more information, visit:
http://edis.ifas.ufl.edu/AE113

5) One or more gutters are poorly sloped so that significant amounts of water accumulate in them rather than draining through the downspouts. This can cause gutters to overflow, especially when organic debris such as leaves or needles have accumulated in them. A qualified contractor should evaluate and make repairs as necessary, such as correcting the slope in gutters or installing additional downspouts and extensions if necessary.
6)   The fence along the east side of the home is falling down and is in need of immediate replacement. A qualified contractor should evaluate and make repairs or replace sections as necessary.

Photo 4  
Fence needs replacement
 

7)   Gutters in one or more areas are significantly rusted or corroded. Leaks may result. A qualified contractor should evaluate and replace gutters where necessary.

Photo 6  
rusted gutter
 

8)   Fascia boards are damaged or deteriorated in one or more areas. A qualified contractor should evaluate and make repairs as necessary.

Photo 7  
water seepage onto facia
 

9)   One or more outside faucets leak. For example, from the valve stem when turned on or from the spigot when turned off. A qualified plumber should evaluate and repair as necessary.
10) The perimeter grading slopes towards the structure in one or more areas. This can result in water accumulating around the structure's foundation, or in basements and crawl spaces if they exist. Accumulated water is a conducive condition to wood destroying insects and organisms. Wet soil may also cause the foundation to settle and possibly fail over time. Recommend grading soil so it slopes down and away from the structure with a slope of at least 5% (10% or better is optimal) for at least 6 feet.

Photo 2  
Moisture retained near foundation
 

11) One or more gutters are damaged. This can result in water accumulating around the structure's foundation, or in basements and crawl spaces if they exist. Accumulated water is a conducive condition to wood destroying insects and organisms, and may also cause the foundation to settle and possibly fail over time. A qualified contractor should replace or repair gutters where necessary.
12)   Western gate is wide and sagging making it difficult to close and latch properly. Repairs should be made as necessary, and by a qualified contractor if necessary, so gates operate easily.

Photo 5  
plants near foundation
 

13) Vegetation such as trees, shrubs and/or vines are in contact with or less than one foot from the structure's exterior. Vegetation can serve as a conduit for wood destroying insects and may retain moisture against the exterior after it rains. Vegetation should be pruned and/or removed as necessary to maintain a one foot clearance between it and the structure's exterior.
14)   Minor cracks were found in the driveway. However they don't appear to be a structural concern and no trip hazards were found. No immediate action is recommended, but the client(s) may wish to have repairs made or have cracked sections replaced for aesthetic reasons.
15)   Wet conditions were observed along the north facing portions of the foundations at the front of the house. Moss is growing at the soil line which appears to have been 12" or more above the finnished floor height from inside the home. This could have led to covered weep holes in the brick veneer and possible water damage as all water draining from the roof was draining back against the home.

Photo 2  
Moisture retained near foundation
 

16)   One or more areas of the grounds around the structure have significantly soggy soil, standing water or indications of accumulated water at times (sediment, dead grass, etc.). Recommend consulting with a qualified contractor who specializes in drainage, to determine if or what repairs are needed to provide adequate drainage. Possible repairs may involve grading soil, or installing, repairing and/or replacing underground drains.
17) Firewood is along the western side of the home so that it's either in contact with the structure or very close to it. This is a conducive condition for wood destroying insects. Recommend storing firewood outdoors in an open area, as far away from the house as practical, to keep away insects. For more information, visit:
http://www.google.com/search?q=firewood+insects

 
Roof Return to table of contents
Roof inspection method: Traversed
Roof type: Hipped
Roof covering: Asphalt or fiberglass composition shingles
Estimated age of roof: 24
Gutter & downspout material: Steel
Roof ventilation: Adequate
18) The roof surface material appears to be near the end of its service life and will likely need replacing in the near future, even with repairs. The client(s) should budget for a replacement roof surface, and may want to have a qualified roofing contractor evaluate and attempt to issue a "5 year roof certificate".

Photo 13  
evidance of shingle replacement
 

19) One or more sections of flashing at the base of the chimney are deteriorated and/or substandard. Leaks may occur as a result. A qualified roofing contractor should evaluate and repair as necessary.

Photo 11  
debris buildup under shingles near chimney flashing
 

20) One or more composition shingles are damaged, deteriorated and/or missing, and should be replaced. Leaks may occur as a result. A qualified roofing contractor should evaluate and make repairs as necessary.

Photo 13  
evidance of shingle replacement
 

21) One or more composition shingles have raised, most likely due to nails that have loosened. Leaks may occur as a result. A qualified roofing contractor should evaluate and make repairs as necessary, such as reseating nails.
22) Debris has accumulated in one or more gutters. This is a conducive condition for wood destroying insects since gutters may overflow and cause water to come in contact with the structure's exterior or make water accumulate around the foundation. Gutters should be cleaned now and as necessary in the future.

Photo 12  
clogged gutters
 

23) Moss is growing on the roof. As a result, shingles may lift or be damaged. Leaks may result and/or the roof surface may fail prematurely. This is a conducive condition for wood destroying insects and organisms. Efforts should be taken to kill the moss during its growing season (wet months). Typically zinc-based chemicals are used for this, and must be applied periodically. For information on various moss treatment products and their pros and cons, visit:
http://www.google.com/search?q=moss+on+roof

Photo 10  
patchwork on cricket

Photo 14  
roof patch

 
Garage Return to table of contents

24)   One or more wall and/or ceiling surfaces between the attached garage and interior living spaces have gaps, holes, or missing or inadequate surface materials. These surfaces are intended to prevent vehicle fumes from entering living spaces, and to slow the spread of fire from the garage to living spaces. A qualified contractor should evaluate and make repairs as necessary so the attached garage wall and ceiling surfaces that adjoin living spaces are tightly sealed and fire rated as per standard building practices. Typically these surfaces require a one-hour fire rating.
25)   Appliances such as the water heater and/or furnace are subject to damage from vehicles because no protective barrier is installed in front of them. A qualified contractor should install an adequate barrier as per standard building practices (steel post anchored in concrete, wood partition, etc.).
26)   Weatherstrip around or at the bottom of the garage-house door is missing. It should be installed where missing and as necessary to prevent vehicle fumes from entering living spaces.

Photo 20  
missing weather striping on garage door
 

27)   Cover plate(s) are missing from one or more electric boxes, such as for receptacles, switches and/or junction boxes. They are intended to contain fire and prevent electric shock from exposed wires. This is a safety hazard due to the risk of fire and shock. Cover plates should be installed where missing.
28)   Weatherstrip at the sides and/or bottom of the vehicle door is missing. It should be installed where missing to prevent water and vermin intrusion.
29)   The weatherstrip around one or more exterior entry doors is missing and/or deteriorated. Weatherstrip should be installed where missing and/or replaced where deteriorated, and by a qualified contractor if necessary.
30)   The interior perimeter of the garage is excluded from this inspection due to lack of access from stored items.

Photo 19  
effloresence present in garage foundation
 

31)   Much of the garage, including areas around the interior perimeter and in the center are excluded from this inspection due to lack of access from stored items.
32)   One or more vehicle doors were inaccessible due to stored items and/or debris, and couldn't be operated or fully evaluated.
 
Attic Return to table of contents
Inspection method: Partially traversed
Roof structure type: Trusses
Ceiling structure: Trusses
Insulation material: Cellulose loose fill
Insulation depth: 6"
Insulation estimated R value: R30
33)   Ceiling insulation is uneven in some areas. This is likely due to someone having walked on or through the insulation. Recommend installing additional insulation where necessary to restore the original R rating.

Photo 35  
Attic scan showing missin insulation under duct.
 

34)   Ceiling insulation is missing in some areas. Recommend installing insulation where missing for better energy efficiency.
35)   Insulation is missing around one or more skylight chases. A qualified contractor should install insulation around skylight chases where missing and as per standard building practices.
36)   No insulation is installed over the attic access hatch. Recommend installing insulation above hatch for better energy efficiency.
37)   No weatherstrip is installed around the attic access hatch. Weatherstrip should be installed around the hatch to prevent heated interior air from entering attic.
38)   The ventilation in the attic is minimum code standard. Recent studies suggest that improving attic ventelation will help reduce wear to the roofing material and improve the effeciency of the insulation. More ventilation may be added at a later time to improve conditions.
 
Electric service Return to table of contents
Primary service type: Underground
Primary service overload protection type: Circuit breakers
Service amperage (amps): 200
Service voltage (volts): 120/240
Location of main service switch: East side of home next to metal gate
Location of sub panels: One sub-panel located on east side of home in the side yard area next to chimney.
Location of main disconnect: Breaker at top of main service panel
Service entrance conductor material: Aluminum
System ground: Cold water supply pipes
Main disconnect rating (amps): 150
Branch circuit wiring type: Copper, Aluminum multi-strand, Aluminum solid-strand
Solid strand aluminum branch circuit wiring present: Yes
Smoke detectors present: Yes
39)   This home has solid-strand branch circuit aluminum wiring. This type of aluminum wiring is a potential fire hazard. Problems due to expansion and contraction can cause overheating at connections between the wire and devices such as switches and receptacles, or at splices. The Consumer Products Safety Commission recommends either discontinuing use of circuits with aluminum wiring, or pigtailing copper wiring onto the ends of the aluminum wire. A qualified electrician should evaluate and repair or replace this wiring. For more information, visit:
http://www.inspect-ny.com/aluminum.htm

Photo 16  
alluminum wireing

Photo 33  
Scan showing heated circut breaker.

40)   One or more connections with aluminum wires in the main service panel lack anti-oxidant paste. Oxidation usually occurs without it, and may result in poor connections, overheating, and possibly fires. A qualified electrician should evaluate and apply anti-oxidant paste as necessary.
41)   One or more screws are missing from the main service panel cover and should be replaced. Because energized wiring may exist behind the holes with the missing screws, recommend that a qualified, licensed electrician replace these screws, or that care be taken to ensure that the new screws do not come in contact with wiring inside the panel when they are installed. Stock screws from the panel manufacturer should be used, or their equivalent.
42)   The electric service to this property appears to be rated at substantially less than 200 amps, and may be inadequate for the client(s) needs. Recommend consulting with a qualified electrician about upgrading to a 200 amp service.
43)   There are two wire that have been cut and spliced in the main breaker panel that appear to lead to the circut breaker marked "referidgerator." this is not necessaraly a problem but may warrant a further evaluation.

Photo 17  
 

44)   The sub panel is protected by a GFCI breaker in the main panel.
 
Water heater Return to table of contents
Estimated age: 6 years
Estimated age: 6
Type: Tank
Energy source: Natural gas
Capacity (in gallons): 40
Manufacturer: State Select
Model: PR640N0
Estimated age: 6
Type: Tank
Energy source: Natural gas
Capacity (in gallons): 40
Manufacturer: State Select
Model: PR640N0CT52
Water temperature (degrees Fahrenheit): 150
Estimated age: 6
Type: Tank
Energy source: Natural gas
Capacity (in gallons): 40
Manufacturer: State Select
Model: PR640N0CT52
Water temperature (degrees Fahrenheit): 150
45)   Energy Useage is estimated to be 242 Therms Per Year
 
Heating and cooling Return to table of contents
Primary heating system energy source: Natural gas
Primary heat system type: Standard efficiency
Primary A/C energy source: Electric
Distribution system: Flexible ducts
Make: Missing Id Plate
Model: Missing Id Plate
Filter location: In return air duct below furnace
Last service date: july 2008
46)   The vent flue on the hot water heater is not properly installed and exaust gasses are venting into the garage.
47)   Insulation on one or more heating/cooling ducts in unconditioned spaces is damaged and/or deteriorated. A qualified contractor should evaluate and replace insulation and/or ducts as necessary and as per standard building practices.
48)   The grounding strap on the hot water heater was cut and never replaced.
49)   One or more hangers or straps supporting heating/cooling duct work are broken. Permanent repairs should be made by a qualified contractor so ducts are adequately supported.
50)   Air handler filter(s) are dirty and should be replaced now. They should be checked monthly in the future and replaced as necessary.
51)   Air handler filter(s) should be checked monthly in the future and replaced or washed as necessary.
 
Plumbing and laundry Return to table of contents
Water pressure (psi): 75
Location of main water shut-off valve: Front of house next to bay window
Location of main water meter: Under cover on main sidewalk
Water service: Public
Service pipe material: Not visible
Supply pipe material: Not visible
Vent pipe material: Not visible
Drain pipe material: Not visible
Waste pipe material: Not visible
52)   Copper water supply pipes in homes built prior to 1986 may be joined with solder that contains lead. Lead is a known health hazard, especially for children. Laws were passed in 1985 prohibiting the use of lead in solder, but prior to that solder normally contained about 50 percent lead. The client(s) should be aware of this, especially if children will be living in this structure. Evaluating for the presence of lead in this structure is not included in this inspection. The client(s) should consider having a qualified lab test for lead, and if necessary take steps to reduce or remove lead from the water supply. Various solutions such as these may be advised:

  • Flush water taps or faucets. Do not drink water that has been sitting in the plumbing lines for more than six hours.
  • Install appropriate filters at points of use.
  • Use only cold water for cooking and drinking. Hot water dissolves lead more quickly than cold water.
  • Use bottled or distilled water.
  • Treat well water to make it less corrosive.
  • Have a qualified plumbing contractor replace supply pipes and/or plumbing components as necessary.

    For more information visit:
    http://www.cpsc.gov/CPSCPUB/PUBS/5056.html
    http://www.epa.gov/safewater/lead/index.html
     
    Fireplaces, woodstoves and chimneys Return to table of contents
    Fireplace type: Zero Clearance
    Chimney type: Metal
    53)   A significant amount of creosote (1/8 inch or more) is visible in the fireplace flue. A qualified chimney service contractor should inspect, clean, and repair if necessary now and annually in the future.
    54)   One or more refractory panels (the 1 inch thick fireproof panels lining the fireplace walls) are significantly cracked. A qualified fireplace or chimney service contractor should evaluate and repair or replace panels as necessary. Repairs typically involve patching cracks with a high temperature resistant refractory mortar or sealant. If panel(s) are not replaced, then recommend monitoring them in the future for further deterioration. Refractory panels should be replaced if cracks exceed 1/4 inch in width, if surface pitting becomes extensive and deeper than 3/16 inch, or if any piece of the refractory larger than 2 inches in radius and 3/16 inch deep becomes dislodged.
    55)   All solid fuel burning appliances (woodstoves and fireplaces, etc.) should be inspected annually by a qualified chimney service contractor, cleaned and repaired as necessary.
     
    Kitchen Return to table of contents

    56) One or more exhaust fans is inoperable or provides inadequate air flow. Moisture may accumulate as a result. A qualified contractor should evaluate and replace the fan or make repairs as necessary.
    57) One or more sink drains have an active leak. For example, at pipe fittings and/or junctions between pipe and sink. A qualified plumber should evaluate and repair as necessary.

    Photo 25  
    plumbing leak in guest bath
     

    58)   No "air gap" is installed for the dishwasher drain line. Air gaps are a device meant to prevent water from the sink drain or food disposal from entering the dishwasher. These are required in some municipalities for new construction and when remodeling. The client(s) should consult with a qualified contractor to determine if an air gap should be installed.
    59)   One or more cabinets and/or drawers are damaged and/or deteriorated. A qualified contractor should evaluate and repair or replace cabinets and/or components as necessary.
    60)   Tile, stone and/or grout countertops are damaged and/or deteriorated in one or more areas. A qualified contractor should evaluate and make repairs as necessary. For example, replacing broken tiles and deteriorated grout, and resealing grout.
    61) Caulk is missing and/or deteriorated where countertops meet backsplashes in wet areas, such as around sinks. Caulk should be replaced where deteriorated and/or applied where missing to prevent water damage.

    Photo 30  
    caulking missing in kitchen sink
     

    62)   Recommend cleaning and sealing grout in countertops now and in the future as necessary to prevent staining and to improve waterproofing.
     
    Bathrooms Return to table of contents

    63)   Aggrogate flooring is not sealed properly. Bathrooms have a musty smell to them indicating that water is being absorbed by the aggrogate floors and is not drying. The floors need to be cleaned and re-sealed or removed completley.

    Photo 24  
    unsealed aggrogate flooring
     

    64) Master Bathroom does not have an exhaust fan installed. Moisture accumulation will occur and may damage the structure. Even if the bathroom has a window that opens, it likely does not provide adequate ventilation, especially during cold weather when the window is closed. A qualified contractor should install exhaust fans as per standard building practices where missing in bathrooms with showers. At the time of construction, the bathroom did meet code requirements.
    65) One or more sink drains have an active leak. For example, at pipe fittings and/or junctions between pipe and sink. A qualified plumber should evaluate and repair as necessary.
    66)   One or more exhaust fans are noisy or vibrate excessively. A qualified contractor should evaluate and replace the fan(s) or make repairs as necessary.
    67)   One or more sink stopper mechanisms are missing, or need adjustment or repair. Stopper mechanisms should be installed where missing and/or repairs should be made so sink stoppers open and close easily.
    68)   Condensation drips were observed along the edge of the sky light opening indicating a lack of ventelation in the bathroom and a lack of insulation along the sky light well opening in the atic.

    Photo 26  
    condensation drips in guest bath
     

    69) Caulk is missing or deteriorated along the base of one or more bathtubs, where flooring meets the tub. It should be replaced where deteriorated and/or applied where missing to prevent water intrusion and damage to the floor structure.
    70) Caulk is missing or deteriorated above one or more bathtubs, where the tub surround meets the tub. It should be replaced where deteriorated and/or applied where missing to prevent water intrusion and damage to the wall structure.
    71) Caulk is missing or deteriorated around the base of one or more bathtub spouts. It should be replaced where deteriorated and/or applied where missing to prevent water intrusion and damage to wall structures.
    72) Caulk is missing and/or deteriorated at one or more bathtubs. For example, where the tub base meets the floor below, where the tub surround meets the tub, and/or around the base of the tub spout. Caulk should be replaced where deteriorated and/or applied where missing to prevent water intrusion and damage to wall and floor structures.
    73) Caulk is missing and/or deteriorated at one or more showers. For example, where the shower base meets the floor below and/or around the shower surround. Caulk should be replaced where deteriorated and/or applied where missing to prevent water intrusion and damage to wall and floor structures.
    74)   The enamel coating on one or more sinks is damaged and/or deteriorated. For example, chipped or worn, and/or rust on some exposed steel. However, no leaks were found due to the deterioration. The client(s) should evaluate to determine if the sinks should be replaced.

    Photo 27  
    master bath sink damage

    Photo 28  

     
    Interior rooms Return to table of contents

    75)   An insufficient number of smoke alarms are installed. Additional smoke alarms should be installed as necessary so a functioning one exists in each hallway leading to bedrooms, and in each bedroom. For more information, visit http://www.cpsc.gov/cpscpub/pubs/5077.html
    76)   Cover plate(s) are broken at one or more electric boxes, such as for receptacles, switches and/or junction boxes. They are intended to contain fire and prevent electric shock from exposed wires. This is a safety hazard due to the risk of fire and shock. Cover plates should be replaced where necessary.

    Photo 8  
    cracked cover plate
     

    77)   Batteries in all the smoke alarms should be replaced after taking occupancy, and annually in the future. "Chirping" noises emitted from smoke alarms typically indicate that batteries need replacing. For more information, visit:
    http://www.cpsc.gov/cpscpub/pubs/5077.html

    78)   One or more ceiling fans wobbles excessively during operation. This is a potential safety hazard and may be caused by one or more of the following:

  • Loose screws
  • Loose blade(s)
  • A loose connection between the rod and the fan body
  • A loose connection between the fan body and the electric box above
  • Misaligned blades
  • Bent or warped blades
  • Unbalanced blades

    Recommend having a qualified contractor evaluate and repair as necessary. For more information, visit:
    http://www.google.com/search?q=unbalanced+ceiling+fans
    79)   Screen(s) in one or more windows are missing. The client(s) should ask the property owner(s) about this. Screens are often removed for window cleaning and they may be stored somewhere. If not, then recommend installing screens where missing.
    80)   One or more sliding glass doors are difficult to open or close. A qualified contractor should evaluate and repair or replace door(s) as necessary.
    81)   Screen(s) in one or more windows are torn or have holes in them. Screens should be replaced where necessary.
    82)   One or more bedroom doors has no gap between it and the floor below, or has a gap substantially less than one inch. This structure has a forced air heating system with centrally located return air ducts. When bedroom doors are closed, the only effective path for return air out of the bedrooms is under the doors. A minimum gap of one inch below bedroom doors is recommended to allow an adequate air flow for return air. Recommend trimming the bottoms of bedroom doors as necessary so each door has a minimum one inch gap at its base.
    83)   The weatherstrip around one or more exterior entry doors is missing and/or deteriorated. Weatherstrip should be installed where missing and/or replaced where deteriorated, and by a qualified contractor if necessary.
    84)   One or more sliding screen doors are damaged and/or deteriorated. Screen doors should be replaced where necessary.
    85)   Screens in one or more sliding doors are torn or have holes in them. Screens should be replaced where necessary.
    86)   Carpeting in one or more rooms is loose. Recommend having a qualified carpeting installation contractor restretch carpet as necessary.

    Photo 22  
    water seepage front room

    Photo 23  
    carpet tacking rotten from watter damage

    87)   Trim is damaged and/or deteriorated in one or more areas. Recommend having a qualified contractor replace or repair trim as necessary.

    Photo 31  
    minor baseboard damage
     

    88)   Carpeting in one or more rooms is soiled and/or stained. Recommend having carpeting professionally cleaned as necessary.
     

    Photo 3  
    light rust on gate

    Photo 15  
    flashing not nailed down

    Photo 18  
    exposed wiring in garage

    Photo 21  
    interior foundation crack

    Photo 29  
    caulking missing

    Photo 32  
    Attic scan of A/C duct shows failing insulation.

    Photo 36  
    Missing insulation in the ceiling.
     

     
    Your default report footer here...