Home Inspection Report
Client(s): Sample Report of Southeast Home Inspections
Property address: 20430 Anywhere Drive Springfield LA 70462
Inspection date: Saturday, June 16, 2007
This report published on 7/4/2007 12:23:11 AM CDT

View summary page

[b]This report is the exclusive property of this inspection company and the client(s) listed in the report title. Use of this report by any unauthorized persons is prohibited. Southeast Home Inspections inspects a home to analyze the MAJOR DEFECTS on premises at time of inspection for the client to evaluate and consider. Southeast Home Inspections makes no warranty as to any component of home inspected and does not perform a technically exhaustive inspection testing all systems by experts but supplies a visual observation of home condition and components for customer determination.

 
How to Read this Report
This report is organized by the property's functional areas.  Within each functional area, descriptive information is listed first and is shown in bold type.  Items of concern follow descriptive information. Concerns are shown and sorted according to these types:
SafetyPoses a risk of injury or death 
Repair/ReplaceRecommend repairing or replacing by a qualified professional. 
Repair/MaintainRecommend repair and/or maintenance 
Minor defectCorrection likely involves only a minor expense 
MaintainRecommend ongoing maintenance 
EvaluateRecommend further evaluation by a qualified professional 
CommentFor your information 

Click here for a glossary of building construction terms.  Contact your inspector if there are terms that you do not understand, or visit the glossary of construction terms at http://www.reporthost.com/glossary.asp

Table of Contents
General Information
Grounds
Exterior / Foundation
Roof / Attic
Electric
Plumbing / Fuel Systems
Water Heater
Cooling / Heat Pump
Fireplaces / Stoves / Chimneys
Kitchen
Bathrooms / Laundry / Sinks
Interior Rooms / Areas
 
General Information Return to table of contents
Report number: 2007061601
Time started: 0900
Time finished: 1115
Present during inspection: Client, Realtor
Client present for discussion at end of inspection: Yes
Weather conditions: Partly cloudy
Temperature: Hot 84 Degrees
Ground condition: Damp
Inspection fee: $300.00
Type of building: Single family
Buildings inspected: Single family wood frame 1.5 story
Number of residential units inspected: 1
Age of building(s): 30+
Source for building age: Inspector's estimate
Front of building faces: Northeast
Main entrance faces: Northeast
Occupied: Yes, Furniture or stored items were present


1) Based on non standard construction observed, additions to this property may have been made without the owner having attained permits or inspections from the municipality. Work may have been performed by someone other than a qualified contractor or person. The client should consult with the property owner about this, and if necessary research permits.

At worst case, if substantial work was performed without permits, this knowledge must be disclosed when the building is sold in the future. This can adversely affect future sales. Also, the local municipality could require costly alterations to bring the building into legal compliance or even require that the additions or modifications be removed.
 
Grounds Return to table of contents
Limitations: The following items are not included in this inspection: swimming pools, spas, hot tubs, water features and related equipment; playground, recreation or leisure equipment; landscape lighting; areas below exterior structures with less than three feet of vertical clearance; irrigation systems; invisible fencing; sea walls, docks and boathouses. Any comments made regarding these items are as a courtesy only. Note that the inspector does not test or determine the adequacy of drainage systems for grounds, walkways, below-grade stairs and roof downspouts. The inspector does not provide an evaluation of geological conditions and/or site stability, compliance of pool or spa fencing with municipal requirements, or determination that deck, balcony and/or stair membranes are watertight.
The following items are excluded from this inspection: Outbuildings, Invisible fencing Pool and deck area
Site profile: Level
Condition of driveway: Appeared serviceable
Driveway material: Poured in place concrete
Condition of sidewalks and/or patios: Appeared serviceable
Sidewalk material: Poured in place concrete
Condition of deck, patio and/or porch covers: Appeared serviceable
Deck, patio, porch cover material and type: Covered (Refer to Roof section)
2) Self-closing devices on one or more gates used with pool or spa fencing were missing. This is a safety hazard because these devices are intended to control access to the pool or spa, especially for children. A qualified person should repair, replace or install as necessary.
3) One or more planter boxes were installed on property in past and have since been removed leaving small holes in siding from screws or nails which should be sealed to prevent moisture instrusion which may lead to rot. Recommend repair to these areas on front of home near windows.
4) Vegetation such as trees, shrubs and/or vines was in contact with or less than one foot from the building exterior. Vegetation can serve as a conduit for wood destroying insects and may retain moisture against the exterior after it rains. Vegetation should be pruned and/or removed as necessary to maintain a one foot clearance between it and the building exterior.
5) Trees were in contact with or were close to the building in one or more areas. Damage may result, especially during high winds. Vegetation can also act as a conduit for wood destroying insects. Vegetation should be pruned back and/or removed as necessary to prevent damage and infestation by wood destroying insects.
6) Minor cracks, settlement, heaving and/or deterioration were found in the driveway. However they don't appear to be a structural concern and no trip hazards were found. No immediate action is recommended, but the client may wish to have repairs made or have cracked sections replaced for aesthetic reasons.
7) Minor cracks, settlement, heaving and/or deterioration were found in one or more sidewalk or patio sections. However they don't appear to be a structural concern and no trip hazards were found. No immediate action is recommended, but the client may wish to have repairs made or have cracked sections replaced for aesthetic reasons.
 
Exterior / Foundation Return to table of contents
Limitations: The following items are not included in this inspection: below-grade foundation walls and footings, or those obscured by vegetation or building components; exterior building surfaces or components obscured by vegetation, stored items or debris. Any comments made regarding these items are as a courtesy only. Some amount of cracking is normal in concrete slabs and foundation walls due to shrinkage and drying. Note that the inspector does not determination the adequacy of sump pumps, seismic reinforcement, nor determine if support posts, columns, beams, joists, studs, trusses, etc. are of adequate size, spanning or spacing.
Condition of wall covering: Appeared serviceable
Apparent wall structure: Wood frame
Wall covering: Vinyl
Condition of foundation and footings: Appeared serviceable
Foundation type: Slab on grade
Foundation material: Poured in place concrete
Footing material: Poured in place concrete
Condition of concrete slab floor(s): Appeared serviceable
8) Rot or water damage was found at one or more sections of soffits, fascia. A qualified person should evaluate and repair as necessary. All rotten wood should be replaced.
9) The exterior finish in some areas was failing. A qualified contractor should prep (pressure wash, scrape, sand, prime caulk, etc.) and repaint or restain areas as needed and as per standard building practices.
10) Many concrete slab floor sections were obscured by furniture, carpeting, flooring and couldn't be fully evaluated.
 
Roof / Attic Return to table of contents
Limitations: The following items or areas are not included in this inspection: areas that could not be traversed or viewed clearly due to lack of access; areas and components obscured by insulation; solar roofing components; any comments made regarding these items are as a courtesy only. Note that the inspector does not determination if rafters, trusses, joists, beams, etc. are of adequate size, spanning or spacing. The inspector does not provide an estimate of remaining roof surface life, does not determine that the roof has absolutely no leaks at the time of the inspection, and does not determine that the roof won't leak in the future. Only active leaks and evidence of past leaks observed during the inspection are reported on as part of this inspection. To absolutely determine than no leaks exist, complete access to all roof structure areas must be available during a wide variety of weather conditions, including prolonged heavy rain, high wind from varying directions, heavy accumulations of snow and/or ice, and melting snow and ice.
Condition of roof structure: Appeared serviceable, Required repair, replacement and/or evaluation (see comments below)
Roof type: Gable
Age of roof surface(s): 10-15 years old
Source for building age: Inspector's estimate
Roof inspection method: Traversed
Condition of shingle and/or shake roof surface materials: Appeared serviceable
Roof surface material: Asphalt or fiberglass composition shingles
Apparent number of layers of roof surface material: One
Condition of metal and/or tile roof surface materials: Appeared serviceable Patio cover
Metal, tile or panel roof surface material: Metal
Condition of exposed flashings: Appeared serviceable
Condition of attic: Appeared serviceable
Attic inspection method: Viewed from hatch(es)
Roof structure type: Rafters
Ceiling structure: Ceiling beams
Ceiling insulation material: Fiberglass roll or batt
Ceiling insulation depth: 4 inches
Vapor retarder: None visible
11) Rot or water damage was found at one or more sections of the roof structure, including: soffits, fascia. A qualified person should evaluate and repair as necessary. All rotten wood should be replaced.
12) Flashings at the base of one or more chimneys were deteriorated. Leaks may occur as a result. A qualified contractor should evaluate and repair as necessary.
13) The attic access hatch was too small to allow easy access for periodic evaluation of the attic. Standard building practices require hatches to be at least 22 by 30 inches in size, and in accessible areas. Recommend having a qualified contractor enlarge the attic access as per standard building practices.
14) Some sections of the roof surface appeared to be near the end of their service life and will likely need replacing in the near future, even with repairs. The client should budget for a replacement roof surface, and may want to have a qualified roofing contractor evaluate and attempt to issue a "5 year roof certificate".
15) Panel edge clips (also known as "H clips") were not installed between roof sheathing panels. Standard building practices require that these be installed with wide truss or rafter spacing (24 inches o.c.) and with thin sheathing (3/8 inch). Lack of these clips may result in sheathing sagging between rafters or trusses. This may also void the warranty on some brands of shingles.
16) All attic and roof structure sections more than 20 feet from the access hatch(es) were inaccessible due to stored items. These areas are excluded from the inspection.
17) Attic spaces greater than 30 inches in height appeared to exist in this building, but access didn't exist at the time of the inspection for reasons stated above. Recommend making adequate access as necessary (move stored items, install hatch, etc.) and evaluating these attic spaces.
 
Electric Return to table of contents
Limitations: The following items are not included in this inspection: generator systems, surge suppressors, inaccessible or concealed wiring; underground utilities and systems; low voltage lighting or lighting on timers or sensors. Any comments made regarding these items are as a courtesy only. Note that the inspector does not determine the adequacy of grounding or bonding, does not determine if this system has an adequate capacity for the client's specific needs, nor determine if this system has any reserve capacity for additions or expansion. The inspector does not operate circuit breakers as part of the inspection, install or change light bulbs, nor determine the operability of every wall switch.
Electric service condition: Appeared serviceable
Primary service type: Underground
Service voltage (volts): 120
Service amperage (amps): 200
Primary service overload protection type: Circuit breakers
Service entrance conductor material: Copper
Main disconnect rating (amps): 200
System ground: Ground rod(s) in soil, Copper
Condition of main service panel: Appeared serviceable
Condition of sub: Appeared serviceable
Location of main service panel #A: Master Bedroom Closet
Location of sub panel #B: Utility room
Location of main disconnect: Breaker at bottom of main service panel
Circuit breakers that were in the "off" position: Kitchen Stove breaker was off in panel box
Branch circuit wiring type: Nonmetallic sheathed
Condition of branch circuit wiring: Serviceable
Solid strand aluminum branch circuit wiring present: None visible
Condition of smoke detectors: Appeared serviceable
Smoke detectors present: Yes
Carbon monoxide detectors present: No
Smoke detector power source: Battery
18) One or more ground fault circuit interrupter (GFCI) electric receptacles wouldn't trip with test instrument at the following "wet" locations: bathroom(s). This is a safety hazard due to the risk of shock. A qualified electrician should evaluate and repair as necessary.
19) One or more electric receptacles at the following "wet" locations appeared to have no ground fault circuit interrupter (GFCI) protection: bathroom(s), exterior. This is a safety hazard due to the risk of shock. Recommend having a qualified electrician evaluate to determine if GFCI protection exists, and if not, repair as necessary. For more information, visit:
http://www.mikeholt.com/documents/nec/pdf/GFCI_requirement_page2.pdf

20) Smoke detectors were missing from bedrooms. Additional smoke detectors should be installed as necessary so a functioning one exists in each hallway leading to bedrooms, in each bedroom, and one each level of the building. For more information, visit http://www.cpsc.gov/cpscpub/pubs/5077.html
21) One or more clamps that secure the electric service's grounding electrode conductor(s) to a grounding rod were loose. Grounding may be substandard as a result and may be a safety hazard for shock. A qualified electrician should evaluate and repair as necessary.
22) One or more wall-mounted exterior light fixtures had wiring that's subject to water intrusion due to caulk not being installed around the light fixture's back plate. Caulk should be applied around the perimeter of back plates where missing. A gap should be left at the bottom for condensation to drain out.
23) Ceiling fans and light fixtures appear to be lower than 6'8" clearance inside home and may need to be lifted higher to prevent someone from walking into light fixture.
24) One or more circuit breakers in panel #A were in the off position. As per the NACHI and ASHI Standards of Practice, the inspector did not attempt to reset or turn back on circuit breaker(s). The client should consult with the property owner to determine why breakers are tripped or off, and have a qualified electrician evaluate and repair if necessary. Breaker marked for stove
25) Many electric receptacles were not evaluated because of furniture, stored items.
 
Plumbing / Fuel Systems Return to table of contents
Limitations: The following items are not included in this inspection: private wells and sewage disposal systems; main, side and lateral sewer lines; gray water systems; pressure boosting systems; incinerating or composting toilets; fire suppression sprinkler systems; water softeners, conditioners or filtering systems; plumbing components concealed within the foundation or building structure, or in inaccessible areas such as below tubs; underground utilities and systems; overflow drains for tubs and sinks; backflow prevention devices. Any comments made regarding these items are as a courtesy only. Note that the inspector does not operate water supply or shut-off valves due to the possibility of valves leaking or breaking when operated. The inspector does not test for lead in the water supply, the water pipes or solder, does not determine if plumbing and fuel lines are adequately sized, and does not determining the existence or condition of underground or above-ground fuel tanks.
Condition of service and main line: Appeared serviceable
Location of main water shut: Right side yard valve in green box
Water service: Public
Water pressure (psi): 59 pounds at 0930
Service pipe material: Copper
Condition of supply lines: Appeared serviceable
Supply pipe material: Copper
Condition of waste lines: Appeared serviceable
Waste pipe material: Plastic
Condition of fuel system: Appeared serviceable
Visible fuel storage systems: Large upright propane tank on left side of home near driveway
26) The propane tank was located where it is subject to damage from vehicles. This is a safety hazard. Repairs or modifications should be made as necessary by a qualified contractor, such as installing barriers or moving the tank.
27) One or more outside faucets were leaking. For example, from the valve stem when turned on or from the spigot when turned off. A qualified plumber should evaluate and repair as necessary.
28) The inspector was not able to find the water meter. Recommend that the client attempt to find the water meter by consulting with the property owner, searching for it themselves, or consulting with the local water municipality. It is especially important to find the meter if no main shut-off valve is found because the meter may be the only way to turn off the water supply in the event of an emergency, such as when a supply pipe bursts.
 
Water Heater Return to table of contents
Limitations: The following items are not included in this inspection: solar water heating systems; circulation systems. Any comments made regarding these items are as a courtesy only. Note that the inspector does not provide an estimate of remaining life on water heaters, does not determine if water heaters are appropriately sized, or perform any evaluations that require a pilot light to be lit.
Condition of water heater: Appeared serviceable
Type: Tank
Energy source: Electricity, Natural gas
Capacity (in gallons): 30, 40
Manufacturer: Rudd
Water temperature (degrees Fahrenheit): 127 degrees
Condition of venting system: Appeared serviceable
Condition of combustion air supply: Appeared serviceable
29) The water heater flame was yellow rather than blue. This may be caused by scale on top of the burner, a dirty burner orifice, the flue being clogged, and/or improper gas pressure. A qualified contractor should evaluate and repair as necessary.
30) Substandard wiring was found for the water heater's power supply due to the following conditions: . This is a safety hazard for fire or shock. A qualified contractor should evaluate and repair as necessary. Top electric panel on water heater is missing a screw and should be secured to prevent inserting object into this area.
31) Gas heater located in kitchen closet has a large amount of rusting in bottom near fire shield area which should be evaluated further by a qualified professional for repairs.
 
Cooling / Heat Pump Return to table of contents
Limitations: The following items are not included in this inspection: humidifiers, dehumidifiers, electronic air filters; thermostat or temperature control accuracy and timed functions; cooling components concealed within the building structure or in inaccessible areas; underground utilities and systems; safety devices and controls (due to automatic operation). Any comments made regarding these items are as a courtesy only. Note that the inspector does not provide an estimate of remaining life on cooling system components, does not determine if cooling systems are appropriately sized, and does not test coolant pressure. Condensation pans and drain lines may clog or leak at any time and should be monitored while in operation in the future.
Condition of cooling system and/or heat pump: Appeared serviceable
Location: Left side and Rear (2 units)
Type: Split system, Heat pump
Estimated age: 5 years old on rear unit, undetermined on left side unit
Approximate tonnage: (2 Ton in Rear), Undetermined on left
Condition of distribution system: Appeared serviceable
Condition of controls: Appeared serviceable
Condition of air filters: Appeared serviceable
32) One or more air filters were dirty. A qualified person should replace filter(s) as necessary. Filters should be checked monthly and maintained as necessary in the future.
33) This system used geothermal energy. It is a specialty system, and only a limited evaluation was performed during the inspection. Recommend further evaluation by a qualified specialist. Grundfos underground thermal heat pump with no legible information on Philco Manufacturers tag to exterior unit.
 
Fireplaces / Stoves / Chimneys Return to table of contents
Limitations: The following items are not included in this inspection: coal stoves, gas logs, chimney flues (except where visible). Any comments made regarding these items are as a courtesy only. Note that the inspector does not determine the adequacy of drafting or sizing in fireplace and stove flues, nor determine if prefabricated or zero clearance fireplaces are installed in accordance with the manufacturer's specifications. The inspector does not perform any evaluations that require a pilot light to be lit.
Condition of fireplaces, stoves: Required repair, replacement and/or evaluation (see comments below)
Location #A: Livingroom/Den area in main house
Fireplace type: Prefabricated
Fuel type: Wood
Condition of chimneys: Required repair, replacement and/or evaluation (see comments below)
Chimney type: Metal
34) The metal fireplace liner at location #A had the following conditions: holes, cracks. This may be a safety hazard for fire, and for combustion fumes entering living spaces. A qualified contractor should evaluate and repair as necessary.
35) Chimney above roof is leaning off center and should be properly straightened. Amateur repairs attempted by attaching guidewires which have completely deteriorated and no longer attached to chimney pipe. Recommend repair by a qualified professional.
36) All solid fuel burning appliances (woodstoves and fireplaces, etc.) should be inspected annually by a qualified chimney service contractor, cleaned and repaired as necessary.
 
Kitchen Return to table of contents
Limitations: The following items are not included in this inspection: free-standing or portable appliances such as dishwashers, trash compactors, refrigerators, freezers, ice makers; specialty appliances such as hot water dispensers, water filters and trash compactors; appliance timers, clocks, cook functions, self and/or continuous cleaning operations, thermostat or temperature control accuracy, and lights. Any comments made regarding these items are as a courtesy only. Note that the inspector does not provide an estimate of the remaining life of appliances, and does not determine the adequacy of operation of appliances such as dishwashers, garbage disposals, trash compactors, ovens, broilers, etc.
Condition of counters: Appeared serviceable
Condition of cabinets: Appeared serviceable
Condition of sinks and related plumbing: Appeared serviceable
Condition of garbage disposal: Appeared serviceable
Condition of dishwasher: Appeared serviceable
Condition of range, cooktop: Required repair, replacement and/or evaluation (see comments below) Evaluate oven
Range, cooktop type: Propane
Condition of refrigerator: Appeared serviceable
Condition of built: Appeared serviceable
37) The oven light was inoperable. Recommend replacing bulb or having repairs made if necessary by a qualified person. Noted that there is a breaker in the off position in main electric panel and should consult with owner to determine if this is the cause of oven light and oven not working.
 
Bathrooms / Laundry / Sinks Return to table of contents
Limitations: The following items are not included in this inspection: overflow drains for tubs and sinks; bidets, heated towel racks, saunas, steam generators, clothes washers, clothes dryers. Any comments made regarding these items are as a courtesy only. Note that the inspector does not determine the adequacy of washing machine drain lines, washing machine catch pan drain lines, or clothes dryer exhaust ducts. The inspector does not operate water supply or shut-off valves for sinks, toilets, bidets, clothes washers, etc. due to the possibility of valves leaking or breaking when operated. The inspector does not determine if shower pans or tub and shower enclosures are water tight, or determine the completeness or operability of any gas piping to laundry appliances.
Location #A: Master Bathroom
Location #B: Hallway 1st floor
Location #C: Second floor bedroom
Location #D: Livingroom/Den Addition
Condition of counters: Appeared serviceable
Condition of cabinets: Appeared serviceable
Condition of sinks and related plumbing: Appeared serviceable
Condition of toilets: Appeared serviceable
Condition of bathtubs and related plumbing: Appeared serviceable
Condition of shower(s) and related plumbing: Appeared serviceable
Condition of ventilation systems: Appeared serviceable
Condition of laundry facilities: Appeared serviceable
Gas supply for laundry equipment present: No
38) The toilet at location #A, B, C was loose. A qualified contractor should remove the toilet(s) for further evaluation and repairs if necessary. A new wax ring should be installed and toilet(s) should be securely anchored to the floor to prevent movement and leaking.
39) The bathtub drain stopper mechanism at location #A, B, C was missing, inoperable. A qualified person should repair or replace as necessary.
 
Interior Rooms / Areas Return to table of contents
Limitations: The following items are not included in this inspection: security, intercom and sound systems; communications wiring; central vacuum systems; elevators and stair lifts; sources of obnoxious odors; cosmetic deficiencies due to normal wear and tear in wall, floor and ceiling surfaces and coverings, or in equipment; deficiencies relating to interior decorating; low voltage and gas lighting systems. Any comments made regarding these items are as a courtesy only. Note that the inspector does not evaluate any areas or items which require moving stored items, furnishings, debris, equipment, floor coverings, insulation or similar materials. The inspector does not test for asbestos, lead, radon, mold, hazardous waste, urea formaldehyde urethane, or any other toxic substance. Some items such as window operability are tested on a sampled basis. The client should be aware that paint may obscure wall and ceiling defects, floor coverings may obscure floor defects, and furnishings may obscure wall, floor and floor covering defects. If furnishings were present during the inspection, recommend a full evaluation of walls, floors and ceilings that were previously obscured when possible. Determining the cause of odors is not within the scope of this inspection.
Exterior door material: Wood
Condition of exterior entry doors: Appeared serviceable
Condition of interior doors: Appeared serviceable
Type of windows: Aluminum
Wall type or covering: Drywall
Condition of walls: Appeared serviceable
Ceiling type or covering: Acoustic spray
Condition of ceilings: Appeared serviceable
Flooring type or covering: Carpet, Wood, Tile
Condition of flooring: Appeared serviceable
40) Guardrails in some areas with drop-offs higher than 30 inches were with gaps over 4". This is a safety hazard. Standard building practices require that they:

  • Be installed at drop-offs higher than 30 inches
  • Be securely and permanently attached
  • Be at least 36 inches in height
  • Not be climbable by children
  • Not have gaps or voids that allow passage of a sphere equal to or greater than four inches in diameter

    A qualified contractor should evaluate and repair, replace or install guardrails as necessary, and as per standard building practices.
    41) One or more ceiling fans are installed less than seven feet from the floor below. This is a safety hazard. A qualified contractor should evaluate and repair as necessary. For example, remove fans, or move them as necessary to maintain a seven foot clearance below. Ideally ceiling fans should be installed at least eight to nine feet above the floor for optimal air flow.
    42) The front door's doorbell appeared to be inoperable. A qualified person should evaluate and repair as necessary.
    43) One or more exterior doors had minor . A qualified person should repair or replace as necessary. Front bottom right glass on front door does not have trim to hold glass in place and should be repaired.
    44) Trim or jambs around one or more exterior doors was deteriorated. A qualified person should repair, replace or install as necessary. Showing signs of rot at base of jamb on one or more exterior doors.
    45) Lock mechanisms on some windows were missing, inoperable. A qualified person should repair as necessary. Repair lock mechanisms in front bedrooms areas.
    46) Minor deterioration or damage was found in floors in one or more areas, including cracked tile. A qualified person should repair as necessary. Addition area at rear of home.
    47) Minor cracks and/or holes were found in walls in one or more areas. They do not appear to be a structural concern, but the client may wish to repair these for aesthetic reasons.
    48) Minor cracks and/or holes were found in ceilings in one or more areas. They do not appear to be a structural concern, but the client may wish to repair these for aesthetic reasons.
    49) The inspector was unable to verify that the glass used in one or more exterior doors was approved safety glass. Glazing that is not approved safety glass located in areas subject to human impact is a safety hazard. Standard building practices generally require that approved safety glass be used in swinging and sliding doors except where "art glass", jalousie windows or glazing smaller than a three inch opening are used. A qualified contractor should evaluate and replace glass if necessary, and as per standard building practices.
    50) All exterior doors don't have a screen door.
    51) Screens in some windows were missing.
     

    Photo 2  
    Concrete driveway with minor cracks

    Photo 3  
    Fireplace chimney with rusted support wires

    Photo 4  
    Missing shingle on dormer

    Photo 5  
    Rot at base of dormer and roof

    Photo 6  
    Deteriorating shingles on ridge

    Photo 7  
    Tree needs to be trimmed back from roof

    Photo 8  
    Missing shingles

    Photo 9  
    Loose ground rod connection

    Photo 10  
    Typical damaged siding

    Photo 11  
    Frame missing around door window repair

    Photo 12  
    Holes at window that need sealing

    Photo 13  
    Non GFCI outlet on exterior

    Photo 14  
    Loose brick that may create trip hazard

    Photo 15  
    Dip in roof indicative of no H Clips on deck sheathing

    Photo 16  
    Air lock seal broken on left side window

    Photo 17  
    Broken shutter on left

    Photo 18  
    Need to seal and install propery channel to shed water

    Photo 19  
    Slight rot at gable rake on right

    Photo 20  
    Seal backplate on light fixture

    Photo 21  
    Rot typical at base of doors

    Photo 22  
    Rot typical at base of doors

    Photo 23  
    Water shut off valve inside green box

    Photo 24  
    Soffit rot on rear near patio

    Photo 25  
    Chimney stack leaning

    Photo 26  
    Broken mirror

    Photo 27  
    Ballusters wider than 4" which can be safety hazard

    Photo 28  
    Greater than 30 inch drop from balluster rails

    Photo 29  
    Hole and crack in firebox behind metal insert

    Photo 30  
    Inaccessible attic area due to stored items
     

     
    Southeast Home Inspections thanks you for the opportunity to help you by evaluating the home you are considering for purchase. If we may be of any assistance with Final Walk Thru Inspections or assist you with Annual Checkups remember we are your building inspection consultants for life!