Property Inspection Report

Client(s):  Prospective buyer
Property address:  4515 W 141 St Hawthorne CA 90250
Inspection date:  Saturday, March 31, 2018

This report published on Tuesday, April 3, 2018 1:44:09 PM PDT

This report is the exclusive property of this inspection company and the client(s) listed in the report title. Use of this report by any unauthorized persons is prohibited.
How to Read this Report
This report is organized by the property's functional areas.  Within each functional area, descriptive information is listed first and is shown in bold type.  Items of concern follow descriptive information. Concerns are shown and sorted according to these types:
Concern typeSafetyPoses a safety hazard
Concern typeRepair/ReplaceRecommend repairing or replacing
Concern typeRepair/MaintainRecommend repair and/or maintenance
Concern typeMaintainRecommend ongoing maintenance
Concern typeEvaluateRecommend evaluation by a specialist
Concern typeCommentFor your information

Click here for a glossary of building construction terms.Contact your inspector If there are terms that you do not understand, or visit the glossary of construction terms at https://www.reporthost.com/glossary.asp

Table of Contents
General Information
Grounds
Exterior and Foundation
Crawl Space
Roof
Attic and Roof Structure
Garage or Carport
Electric
Plumbing / Fuel Systems
Water Heater
Heating, Ventilation and Air Condition (HVAC)
Kitchen
Bathrooms, Laundry and Sinks
Interior, Doors and Windows

View summary


General Information
Return to table of contents

Time started: 9:00 A.M.
Time finished: 10:30 A.M
Present during inspection: Client, Realtor
Client present for discussion at end of inspection: Yes
Weather conditions during inspection: Dry (no rain)
Inspection fee: 275.00
Payment method: Cash
Type of building: Single family
Buildings inspected: One house
Number of residential units inspected: 1
Age of main building: 1950
Source for main building age: Inspector's estimate
Occupied: Yes

1) This property(ies) was, were, or may have been built prior to 1979 and may contain lead-base paint and/or asbestos in various building materials such as insulation, siding, and/or ceilings, wall and floor tiles. Both lead and asbestos are known health hazards. Evaluating for the presence of lead, lead-base paint and/or asbestos is not included in this inspection. The client should consult with a specialist, such as industrial hygienists, pest control company, professional labs or abatement contractors for this type of evaluation. For additional information on lead, asbestos and other hazardous materials in homes you may visit the following sites. www.epa.gov www.spsc.gov www.cdc.gov Asbestos is harmless undisturbed, it becomes harmful if disturbed and fibers become air born.

2)   General Company Disclosure
Dear Customer: Thank you for choosing So. Cal Property Inspections to perform the following inspection on the property you wish to purchase. This report is the exclusive property of So. Cal Property Inspections and the individual/s paying for the inspection fee and report. Use of this report by any unauthorized persons is prohibited. All findings should be made to So. Cal Property Inspections. This report represents our professional opinion of the condition of the inspected elements of the subject property, determine during a limited time inspection. This inspection was performed, where applicable, in a manner consistent with the standards of the home inspection industry, terms and conditions of the inspection agreement and limitations noted in the inspection agreement. Information contained herein was prepared exclusively for the named client and their authorized representatives. We have inspected the subject property and must report to you exactly what we found. Because of the age, design and location of the home, we might find some hairline cracks on driveways or walls, see paint peeling off Walls, cracks on tiles, chipped bathtubs or some cracks over windows and doors. These are normal and cosmetic conditions. While due care was exercised in the performance of this inspection, the company makes no representations or guarantees with respect to latent deficiencies or future conditions as part of the inspection or this report. This report is valid only for a period of thirty (30) days from the date of the inspection. This report, including any attachments, should be reviewed in its entirety. Any questions about the inspection or report should be resolved prior to title transfer. This inspection report was prepared in a format specifically for the individual/s paying for the inspections fee and report and such transfer does not cover all potential areas of concern a third party may have. This report is transferable only with the consent of the individual/s paying for inspections fee and report and such transfer does not imply any warranty or guarantee regarding the report by inspection firm. We appreciate the opportunity to conduct this inspection for you! Please carefully read your entire Inspection Report. Call us after you have reviewed your emailed report, so we can go over any questions you may have. Remember, when the inspection is completed and the report is delivered, we are still available to you for any questions you may have, throughout the entire closing process.

1.1. A general inspection is a non-invasive, visual examination of the accessible areas of a residential property (as delineated below), performed for a fee, which is designed to identify defects within specific systems and components defined by these Standards that are both observed and deemed material by the inspector. The scope of work may be modified by the Client and Inspector prior to the inspection process.

The general inspection is based on the observations made on the date of the inspection, and not a prediction of future conditions.

The general inspection will not reveal every issue that exists or ever could exist, but only those material defects observed on the date of the inspection.
1.2. A material defect is a specific issue with a system or component of a residential property that may have a significant, adverse impact on the value of the property, or that poses an unreasonable risk to people. The fact that a system or component is near, at or beyond the end of its normal useful life is not, in itself, a material defect.

1.3. A general inspection report shall identify, in written format, defects within specific systems and components defined by these Standards that are both observed and deemed material by the inspector. Inspection reports may include additional comments and recommendations.


From International Standards of Practice for Performing a General Home Inspection - InterNACHI http://www.nachi.org/sop.htm#ixzz3589FAHda

3)   This is an Agreement between So. Cal Property Inspections, the undersigned Client, and us, the Inspector, pertaining to our inspection of the subject property.

The terms below govern this Agreement.
1. You will pay So. Cal Property Inspections. for our inspection services.
2. We will perform a visual inspection of the home/building and provide you with a written report identifying the defects that we (1) observed and (2) deemed material. The report is only supplementary to the sellers disclosure.

3. Unless otherwise noted in this Agreement or it is not possible, We will perform the inspection in accordance with the current Standards of Practice of the International Association of Certified Home Inspectors posted at http://www.nachi.org/sop.htm. You understand that these standards contain limitations, exceptions, and exclusions. You understand that InterNACHI is not a party to this Agreement, has no control over us, and does not supervise us.

4. Unless otherwise indicated in writing, we will NOT test for the presence of radon a colorless, odorless, radioactive gas that may be harmful to humans. Unless otherwise indicated in writing, we will not test for mold. Unless otherwise indicated in writing, we will not test for compliance with applicable building codes or for the presence of or for any potential dangers arising from the presence of asbestos, lead paint, formaldehyde, soil contamination, and other environmental hazards or violations. If any structure or portion of any structure that is to be inspected is a log home, log structure or includes similar log construction, you understand that such structures have unique characteristics that may make it impossible for us to inspect and evaluate them. Therefore, the scope of our inspection will not include decay of the interior of logs in log walls, log foundations or roofs, or similar defects.

5. Our inspection and report are for your use only. You give us permission to discuss observations with real estate agents, owners, repair persons, or other interested parties. You will be the sole owner of the report and all rights to it. We are not responsible for use or misinterpretation by third parties, and third parties who rely on it in any way do so at their own risk and release us (including employees and business entities) from any liability whatsoever. If you or any person acting on your behalf provide the report to a third party who then sues you and/or us, you release us for any liability agree to pay our costs and legal fees in defending any action naming us. Our inspection and report are in no way a guarantee or warranty, express or implied, regarding the future use, operability, habitability or suitability of the home/building or its components. We disclaim all warranties, express or implied, to the fullest extent allowed by law.

6. We assume no liability for the cost of repair or replacement of unreported defects or deficiencies either current or arising in the future. You agree that in all cases our liability shall be limited to liquidated damages in an amount not greater than the fee you paid us. You waive any claim for consequential, exemplary, special or incidental damages or for the loss of the use of the home/building. You acknowledge that the liquidated damages are not a penalty, but that we intend them to (i) reflect the fact that actual damages may be difficult and impractical to ascertain; (ii) allocate risk between us; and (iii) enable us to perform the inspection for the agreed upon fee.

7. We do not perform engineering, architectural, plumbing, or any other job function requiring an occupational license in the jurisdiction where the property is located. If we hold a valid occupational license, we may inform you of this and you may hire us to perform additional functions. Any agreement for such additional services shall be in a separate writing.

8. If you believe you have a claim against us, you agree to provide us with the following: (1) written notification of adverse conditions within seven days of discovery; and (2) immediate access to the premises. Failure to comply with these conditions releases us from liability.

9. You agree that any litigation arising out of this Agreement shall be filed only in the Court having jurisdiction in the County where we have our principal place of business. If you fail to prove any claim against us, you agree to pay all our legal costs, expenses and fees incurred in defending that claim. You agree that any legal action against InterNACHI itself, allegedly arising out of this Agreement or our membership in InterNACHI, must be brought only in the District Court of Boulder County, Colorado. Before bringing any such action, you must provide InterNACHI with 30 days%u2019 written notice of the nature of the claim. In any action against us or InterNACHI, you waive trial by jury.

10. If a court declares any provision of this Agreement invalid, the remaining provisions remain in effect. This Agreement represents our entire agreement; there are no terms or promises other than those set forth herein. No statement or promise by us shall be binding unless reduced to writing and signed by one of our authorized officers. Any modification of this Agreement must be in writing and signed by you and by one of our authorized officers. This Agreement shall be binding upon and enforceable by the parties and their heirs, executors, administrators, successors and assignees. You will have no cause of action against us after one year from the date of the inspection.

11. Payment of the inspection fee (less any deposit noted above) is due when we complete the inspection. You agree to pay all costs and attorney%u2019s fees incurred in collecting the fee owed to us. If the Client is a corporation, LLC, or similar entity, you personally guarantee payment of the fee.

12. If you request a re-inspection, the re-inspection is subject to the terms of this Agreement.

13. You may not assign this Agreement.

14. If a court finds any term of this Agreement ambiguous or that it otherwise requires judicial interpretation, the court shall not construe that term against us by reason of the rule that any ambiguity in a document is construed against the party drafting it. You had the opportunity to consult qualified counsel before signing this Agreement.

15. If there is more than one clients than the names on order form all clients are subject to this agreement.

Grounds
Return to table of contents

Limitations: Unless specifically included in the inspection, the following items and any related equipment, controls, electric systems and/or plumbing systems are excluded from this inspection: detached buildings or structures; fences and gates; retaining walls; underground drainage systems, catch basins or concealed sump pumps; swimming pools and related safety equipment, spas, hot tubs or saunas; whether deck, balcony and/or stair membranes are watertight; trees, landscaping, properties of soil, soil stability, erosion and erosion control; ponds, water features, irrigation or yard sprinkler systems; sport courts, playground, recreation or leisure equipment; areas below the exterior structures with less than 3 feet of vertical clearance; invisible fencing; sea walls, docks and boathouses; retractable awnings. Any comments made regarding these items are as a courtesy only.
Site profile: Level
Condition of driveway: Appeared serviceable
Driveway material: Poured in place concrete
Condition of sidewalks and/or patios: Appeared serviceable
Sidewalk material: Poured in place concrete

4) Grounds needed maintenance in one or more areas. Recommend having a landscaping specialist further evaluate and make necessary repairs.
Photo
Photo 4-1
Photo
Photo 4-2
Photo
Photo 4-3
 

5) Minor deterioration (e.g. cracks, holes, settlement, heaving) was found in the driveway, but no trip hazards were found. The client may wish to have repairs made for cosmetic reasons.
Photo
Photo 5-1
Photo
Photo 5-2

6) Minor deterioration (e.g. cracks, holes, settlement, heaving) was found in sidewalks or patios, but no trip hazards were found. The client may wish to have repairs made for cosmetic reasons.
Photo
Photo 6-1
 

7) At the time of the inspection it was noted that the ground areas were overall in serviceable condition.
Photo
Photo 7-1
Photo
Photo 7-2
Photo
Photo 7-3
Photo
Photo 7-4
Photo
Photo 7-5
Photo
Photo 7-6
Photo
Photo 7-7
Photo
Photo 7-8

Exterior and Foundation
Return to table of contents

Limitations: The inspector performs a visual inspection of accessible components or systems at the exterior. Items excluded from this inspection include below-grade foundation walls and footings; foundations, exterior surfaces or components obscured by vegetation, stored items or debris; wall structures obscured by coverings such as siding or trim. Some items such as siding, trim, soffits, vents and windows are often high off the ground, and may be viewed using binoculars from the ground or from a ladder. This may limit a full evaluation. Regarding foundations, some amount of cracking is normal in concrete slabs and foundation walls due to shrinkage and drying. Note that the inspector does not determine the adequacy of seismic reinforcement.
Condition of wall exterior covering: Appeared serviceable
Apparent wall structure: Wood frame
Wall covering: Stucco
Condition of foundation and footings: Appeared serviceable
Apparent foundation type: Crawl space, Post and pier
Foundation/stem wall material: Poured in place concrete, Post and pier construction, no stem wall
Footing material (under foundation stem wall): Poured in place concrete

8) Cracks, deterioration and/or damage were found in one or more areas of the exterior stucco finish. In damp climates, moisture can enter cracks or damaged areas and further deteriorate the stucco. Also the wall behind the stucco can become damaged from moisture. Note that areas behind the stucco are inaccessible and excluded from this inspection. Recommend that a qualified contractor repair or replace stucco as necessary.
Photo
Photo 8-1
Photo
Photo 8-2
Photo
Photo 8-3
 

9) A wasp nest was noted in the eaves. Recommend removing nest as needed.
Photo
Photo 9-1
 

10) The paint or stain finish in some areas was failing (e.g. peeling, faded, worn, thinning). Siding and trim with a failing finish can be damaged by moisture.Recommend that a qualified contractor prep (e.g. clean, scrape, sand, prime, caulk) and repaint or restain the building exterior where necessary and per standard building practices. Any repairs needed to the siding or trim should be made prior to this.
Photo
Photo 10-1
Photo
Photo 10-2

11) At the time of the inspection it was noted that the exterior of the property was overall in serviceable condition. Please note that if any exterior area is visually obstructed by stored items or vegetation, these areas will not be fully evaluated and will be excluded from this report.
Photo
Photo 11-1
Photo
Photo 11-2
Photo
Photo 11-3
Photo
Photo 11-4
Photo
Photo 11-5
Photo
Photo 11-6
Photo
Photo 11-7
Photo
Photo 11-8
Photo
Photo 11-9
Photo
Photo 11-10
Photo
Photo 11-11
Photo
Photo 11-12
Photo
Photo 11-13
Photo
Photo 11-14
Photo
Photo 11-15
 

Crawl Space
Return to table of contents

Limitations: Structural components such as joists and beams, and other components such as piping, wiring and/or ducting that are obscured by under-floor insulation are excluded from this inspection. The inspector does not determine if support posts, columns, beams, joists, studs, trusses, etc. are of adequate size, spanning or spacing.

The inspector does not guarantee or warrant that water will not accumulate in the crawl spaces in the future. Complete access to all crawl space areas during all seasons and during prolonged periods of all types of weather conditions (e.g. heavy rain, melting snow) would be needed to do so.

The inspector attempts to locate all crawl space access points and areas. Access points may be obscured or otherwise hidden by furnishings or stored items. In such cases, the client should ask the property owner where all access points are that are not described in this inspection, and have those areas inspected. Note that crawl space areas should be checked at least annually for water intrusion, plumbing leaks and pest activity.
Crawl space inspection method: Traversed
Condition of floor substructure above crawl space: Appeared serviceable
Pier or support post material: Wood
Beam material: Solid wood
Floor structure: Solid wood joists
Condition of insulation underneath floor above: Not applicable, none installed
Insulation material underneath floor above: None visible
Condition of vapor barrier: Not applicable, none installed
Vapor barrier present: None visible
Condition of crawl space ventilation: Appeared serviceable
Ventilation type: Conditioned (heated) space

12) At the time of the inspection it was noted that the crawl space areas was overall in serviceable condition. There were no major signs of damage to the footing, pier/post, and sub-flooring areas. Please note that So. Cal Property Inspections does not guarantee that any area of the foundation is free to any type of structural issues. If a guarantee is to be made it should be done so by a licensed foundation engineer.
Photo
Photo 12-1
Photo
Photo 12-2
Photo
Photo 12-3
Photo
Photo 12-4
Photo
Photo 12-5
Photo
Photo 12-6
Photo
Photo 12-7
Photo
Photo 12-8
Photo
Photo 12-9
Photo
Photo 12-10
Photo
Photo 12-11
 

Roof
Return to table of contents

Limitations: The following items or areas are not included in this inspection: areas that could not be traversed or viewed clearly due to lack of access; solar roofing components. Any comments made regarding these items are made as a courtesy only. Note that the inspector does not provide an estimate of remaining life on the roof surface material, nor guarantee that leaks have not occurred in the roof surface, skylights or roof penetrations in the past. Regarding roof leaks, only active leaks, visible evidence of possible sources of leaks, and evidence of past leaks observed during the inspection are reported on as part of this inspection. The inspector does not guarantee or warrant that leaks will not occur in the future. Complete access to all roof and attic spaces during all seasons and during prolonged periods of all types of weather conditions (e.g. high wind and rain, melting snow) would be needed to do so. Regarding the roof drainage system, unless the inspection was conducted during and after prolonged periods of heavy rain, the inspector was unable to determine if gutters, downspouts and extensions performed adequately or were leak-free.
Roof inspection method: Traversed
Condition of roof surface material: Appeared serviceable
Roof surface material: Asphalt or fiberglass composition shingles
Roof type: Gable
Apparent number of layers of roof surface material: One
Condition of exposed flashings: Appeared serviceable

13) At the time of the inspection it was noted that the roof structure was found to be in serviceable condition. Please note that So. Cal Property Inspections does not guarantee that the roof structure is free of any leaks or structural deficiencies. If the client wishes for a guarantee to be made in respects to the roof structure, it is recommended to consult with a licensed roofing contractor to provide such a guarantee.
Photo
Photo 13-1
Photo
Photo 13-2
Photo
Photo 13-3
Photo
Photo 13-4
Photo
Photo 13-5
Photo
Photo 13-6
Photo
Photo 13-7
Photo
Photo 13-8
Photo
Photo 13-9
Photo
Photo 13-10
Photo
Photo 13-11
Photo
Photo 13-12
Photo
Photo 13-13
Photo
Photo 13-14
Photo
Photo 13-15
 

Attic and Roof Structure
Return to table of contents

Limitations: The following items or areas are not included in this inspection: areas that could not be traversed or viewed clearly due to lack of access; areas and components obscured by insulation. Any comments made regarding these items are made as a courtesy only. The inspector does not determine the adequacy of the attic ventilation system. Complete access to all roof and attic spaces during all seasons and during prolonged periods of all types of weather conditions (e.g. high/low temperatures, high/low humidity, high wind and rain, melting snow) would be needed to do so. The inspector is not a licensed engineer and does not determine the adequacy of roof structure components such as trusses, rafters or ceiling beams, or their spacing or sizing.
Attic inspection method: Viewed from hatch(es), Traversed
Condition of roof structure: Appeared serviceable
Roof structure type: Trusses
Ceiling structure: Trusses, Ceiling joists, Ceiling beams
Condition of insulation in attic (ceiling, skylight chase, etc.): Appeared serviceable
Ceiling insulation material: Fiberglass loose fill
Approximate attic insulation R value (may vary in areas): R-11
Vapor retarder: None
Condition of roof ventilation: Appeared serviceable
Roof ventilation type: Open soffit vents

14) At the time of the inspection it was noted that the attic area was overall in serviceable condition. Please note that if any area of the attic is visually obstructed or has height restrictions; these areas will not be fully evaluated and will be excluded from this report.
Photo
Photo 14-1
Photo
Photo 14-2
Photo
Photo 14-3
Photo
Photo 14-4
Photo
Photo 14-5
Photo
Photo 14-6
Photo
Photo 14-7
Photo
Photo 14-8
Photo
Photo 14-9
 

15)   Termite damage was noted in one or more studs. Recommend having a licensed termite inspector further evaluate and make necessary repairs.
Photo
Photo 15-1
Photo
Photo 15-2
Photo
Photo 15-3
 

Garage or Carport
Return to table of contents

Limitations: The inspector does not determine the adequacy of firewall ratings. Requirements for ventilation in garages vary between municipalities.
Type: Attached
Condition of garage: Appeared serviceable
Type of door between garage and house: Solid core
Condition of garage vehicle door(s): Appeared serviceable
Type of garage vehicle door: Sliding
Condition of automatic opener(s): Appeared serviceable
Mechanical auto-reverse operable (reverses when meeting reasonable resistance during closing): Yes
Condition of garage floor: Appeared serviceable

16) Garage footing had a minor crack. Recommend having a licensed contractor further evaluate and make necessary repairs if needed.
Photo
Photo 16-1
Photo
Photo 16-2

17) Minor cracks were found in the concrete slab floor. These are common and appeared to be only a cosmetic issue.
Photo
Photo 17-1
Photo
Photo 17-2

18) At the time of the inspection it was noted that the structure of the garage area was overall in serviceable condition. Please note that if any area of the garage is visually obstructed by stored items and or vehicles, these areas will not be fully evaluated and will be excluded from this report.
Photo
Photo 18-1
Photo
Photo 18-2
Photo
Photo 18-3
Photo
Photo 18-4
Photo
Photo 18-5
Photo
Photo 18-6

Electric
Return to table of contents

Limitations: The following items are not included in this inspection: generator systems, transfer switches, surge suppressors, inaccessible or concealed wiring; underground utilities and systems; low-voltage lighting or lighting on timers or sensors. Any comments made regarding these items are as a courtesy only. Note that the inspector does not determine the adequacy of grounding or bonding, if this system has an adequate capacity for the client's specific or anticipated needs, or if this system has any reserve capacity for additions or expansion. The inspector does not operate circuit breakers as part of the inspection, and does not install or change light bulbs. The inspector does not evaluate every wall switch or receptacle, but instead tests a representative number of them per various standards of practice. When furnishings, stored items or child-protective caps are present some receptacles are usually inaccessible and are not tested; these are excluded from this inspection. Receptacles that are not of standard 110 volt configuration, including 240-volt dryer receptacles, are not tested and are excluded. The functionality of, power source for and placement of smoke and carbon monoxide alarms is not determined as part of this inspection. Upon taking occupancy, proper operating and placement of smoke and carbon monoxide alarms should be verified and batteries should be changed. These devices have a limited lifespan and should be replaced every 10 years. The inspector attempts to locate and evaluate all main and sub-panels. However, panels are often concealed. If panels are found after the inspection, a qualified electrician should evaluate and repair if necessary. The inspector attempts to determine the overall electrical service size, but such estimates are not guaranteed because the overall capacity may be diminished by lesser-rated components in the system. Any repairs recommended should be made by a licensed electrician.
Electric service condition: Appeared serviceable
Primary service type: Overhead
Service voltage (volts): 3 phase, 4 wire, 120
Estimated service amperage: Not determined (components inaccessible or obscured)
Primary service overload protection type: Circuit breakers
Main disconnect rating (amps): Not determined
System ground: Ground rod(s) in soil, Cold water supply pipes
Condition of branch circuit wiring: Serviceable
Branch circuit wiring type: Copper
Solid strand aluminum branch circuit wiring present: None visible
Smoke alarms installed: Yes, but not tested
Carbon monoxide alarms installed: Yes, but not tested

19) One or more ground fault circuit interrupter (GFCI) receptacles (outlets) wouldn't trip with a test instrument at the . This is a potential shock hazard. Recommend that a qualified electrician evaluate and repair as necessary.
Photo
Photo 19-1
Photo
Photo 19-2
Photo
Photo 19-3
Photo
Photo 19-4

20) One or more electric receptacles (outlets) were incorrectly wired with "false grounds" where the receptacle's ground screw is connected to the neutral or white wire in the circuit. Such receptacles may appear to be grounded when they aren't. This is a shock hazard, and can damage equipment plugged into such receptacles. Recommend that a qualified electrician repair as necessary. For more information, visit:
http://www.reporthost.com/?FLSGRND
Photo
Photo 20-1
Photo
Photo 20-2
Photo
Photo 20-3
Photo
Photo 20-4

21) One or more electric receptacles (outlets) appeared to have no power. Recommend asking the property owner about this. Switches may need to be operated to make some receptacles energized. If necessary, recommend that a qualified electrician evaluate and repair.
Photo
Photo 21-1
Photo
Photo 21-2

22) One or more branch circuit wires in panel(s) #A appeared to be undersized for their circuit breaker or fuse. This is a potential fire hazard. Recommend that a qualified electrician repair as necessary.
Photo
Photo 22-1
 

23) Wire splices were exposed and were not contained in a covered junction box. This is a potential shock or fire hazard. Recommend that a qualified electrician repair per standard building practices. For example, by installing permanently mounted junction boxes with cover plates where needed to contain wiring splices.
Photo
Photo 23-1
Photo
Photo 23-2

24) At the time of the inspection it was noted that the electrical panel was overall in serviceable condition. Breakers would trip, the wiring was installed correctly, and there was a sufficient amount of power going into the property. Please note that So. Cal Property Inspections does not guarantee that the property is free of any type of electrical issues. If the client wishes for a guarantee to be made in respects to the electrical system in the entire property, it is recommended to have a licensed electrician provide such a guarantee.
Photo
Photo 24-1
Photo
Photo 24-2
Photo
Photo 24-3
Photo
Photo 24-4
Photo
Photo 24-5
Photo
Photo 24-6
Photo
Photo 24-7
Photo
Photo 24-8
Photo
Photo 24-9
Photo
Photo 24-10

Plumbing / Fuel Systems
Return to table of contents

Limitations: The following items are not included in this inspection: private/shared wells and related equipment; private sewage disposal systems; hot tubs or spas; main, side and lateral sewer lines; gray water systems; pressure boosting systems; trap primers; incinerating or composting toilets; fire suppression systems; water softeners, conditioners or filtering systems; plumbing components concealed within the foundation or building structure, or in inaccessible areas such as below tubs; underground utilities and systems; overflow drains for tubs and sinks; backflow prevention devices. Any comments made regarding these items are as a courtesy only. Note that the inspector does not operate water supply or shut-off valves due to the possibility of valves leaking or breaking when operated. The inspector does not test for lead in the water supply, the water pipes or solder, does not determine if plumbing and fuel lines are adequately sized, and does not determine the existence or condition of underground or above-ground fuel tanks.
Condition of service and main line: Appeared serviceable
Water service: Public
Location of main water shut-off: Building exterior
Condition of supply lines: Appeared serviceable
Supply pipe material: Copper
Condition of drain pipes: Appeared serviceable
Drain pipe material: Plastic
Condition of waste lines: Appeared serviceable
Waste pipe material: Plastic
Vent pipe condition: Appeared serviceable
Vent pipe material: Plastic
Condition of fuel system: Appeared serviceable
Visible fuel storage systems: Above ground
Location of main fuel shut-off valve: At gas meter

25) Steel piping for the gas service located outside was significantly corroded. Gas leaks can result. Recommend evaluation by a qualified contractor to determine if piping needs replacing. If not, then a qualified person should prep and paint lines as necessary with a rust-preventative paint. Very corroded pipes should be replaced by a qualified contractor.
Photo
Photo 25-1
Photo
Photo 25-2

26) At the time of the inspection it was noted that the plumbing system was overall in serviceable condition. Please note that So. Cal Property Inspections does not guarantee that the plumbing and drainage system is free of any leaking or clogging at any point. If the client wishes for a guarantee to be made in respects that the plumbing and drainage system, it is recommended to consult with a licensed plumbing contractor, and for the contractor to perform an in depth evaluation of the plumbing and drainage system and provide guarantee as he see's fit.

27) At the time of the inspection it was noted that the gas meter area was overall in serviceable condition.
Photo
Photo 27-1
 

Water Heater
Return to table of contents

Limitations: Evaluation of and determining the adequacy or completeness of the following items are not included in this inspection: water recirculation pumps; solar water heating systems; Energy Smart or energy saver controls; catch pan drains. Any comments made regarding these items are as a courtesy only. Note that the inspector does not provide an estimate of remaining life on water heaters, does not determine if water heaters are appropriately sized, or perform any evaluations that require a pilot light to be lit or a shut-off valve to be operated.
Condition of water heater: Appeared serviceable
Type: Tank
Energy source: Natural gas
Capacity (in gallons): 40
Location of water heater: Garage
Condition of burners: Appeared serviceable

28) At the time of the inspection it was noted that the water heater was overall in serviceable condition.
Photo
Photo 28-1
Photo
Photo 28-2
Photo
Photo 28-3
Photo
Photo 28-4
Photo
Photo 28-5
 

Heating, Ventilation and Air Condition (HVAC)
Return to table of contents

Limitations: The following items are not included in this inspection: humidifiers, dehumidifiers, electronic air filters; solar, coal or wood-fired heat systems; thermostat or temperature control accuracy and timed functions; heating components concealed within the building structure or in inaccessible areas; underground utilities and systems; safety devices and controls (due to automatic operation). Any comments made regarding these items are as a courtesy only. Note that the inspector does not provide an estimate of remaining life on heating or cooling system components, does not determine if heating or cooling systems are appropriately sized, does not test coolant pressure, or perform any evaluations that require a pilot light to be lit, a shut-off valve to be operated, a circuit breaker to be turned "on" or a serviceman's or oil emergency switch to be operated. It is beyond the scope of this inspection to determine if furnace heat exchangers are intact and free of leaks. Condensation pans and drain lines may clog or leak at any time and should be monitored while in operation in the future. Where buildings contain furnishings or stored items, the inspector may not be able to verify that a heat source is present in all "liveable" rooms (e.g. bedrooms, kitchens and living/dining rooms).
General heating system type(s): Furnace

29) At the time of the inspection it was noted that the heating system was overall in serviceable condition.
Photo
Photo 29-1
Photo
Photo 29-2
Photo
Photo 29-3
Photo
Photo 29-4
Photo
Photo 29-5
Photo
Photo 29-6
Photo
Photo 29-7
Photo
Photo 29-8
Photo
Photo 29-9
Photo
Photo 29-10
Photo
Photo 29-11
Photo
Photo 29-12

Kitchen
Return to table of contents

Limitations: The following items are not included in this inspection: household appliances such as stoves, ovens, cook tops, ranges, warming ovens, griddles, broilers, dishwashers, trash compactors, refrigerators, freezers, ice makers, hot water dispensers and water filters; appliance timers, clocks, cook functions, self and/or continuous cleaning operations, thermostat or temperature control accuracy, and lights. Any comments made regarding these items are as a courtesy only. Note that the inspector does not provide an estimate of the remaining life of appliances, and does not determine the adequacy of operation of appliances. The inspector does not note appliance manufacturers, models or serial numbers and does not determine if appliances are subject to recalls. Areas and components behind and obscured by appliances are inaccessible and excluded from this inspection.
Condition of counters: Appeared serviceable
Condition of cabinets: Appeared serviceable
Condition of sinks and related plumbing: Appeared serviceable
Condition of under-sink food disposal: Appeared serviceable

30) The sink had minor wear, blemishes or deterioration.
Photo
Photo 30-1
 

31) At the time of the inspection it was noted that the kitchen area was overall in serviceable condition. Please not that if any area of the kitchen is visually obstructed by stored items will not be evaluated and will be excluded from this report.
Photo
Photo 31-1
Photo
Photo 31-2
Photo
Photo 31-3
Photo
Photo 31-4
Photo
Photo 31-5
Photo
Photo 31-6
Photo
Photo 31-7
 

32) At the time of the inspection it was noted that the kitchen appliances appeared to be in serviceable condition.
Photo
Photo 32-1
Photo
Photo 32-2
Photo
Photo 32-3
Photo
Photo 32-4
Photo
Photo 32-5
Photo
Photo 32-6
Photo
Photo 32-7
 

33) Dishwasher had dishes in it. The inspecotor was unable to fully evaluate the dishwasher and is excluding it from this report.
Photo
Photo 33-1
 

34) Stove would not light up when the inspector turned the control to the on position. Recommend asking owner about this and see if repairs are needed.
Photo
Photo 34-1
Photo
Photo 34-2

Bathrooms, Laundry and Sinks
Return to table of contents

Limitations: The following items are not included in this inspection: overflow drains for tubs and sinks; heated towel racks, saunas, steam generators, clothes washers, clothes dryers. Any comments made regarding these items are as a courtesy only. Note that the inspector does not determine the adequacy of washing machine drain lines, washing machine catch pan drain lines, or clothes dryer exhaust ducts. The inspector does not operate water supply or shut-off valves for sinks, toilets, bidets, clothes washers, etc. due to the possibility of valves leaking or breaking when operated. The inspector does not determine if shower pans or tub and shower enclosures are water tight, or determine the completeness or operability of any gas piping to laundry appliances.
Location #A: Full bath
Location #B: Full bath
Condition of counters: Appeared serviceable
Condition of cabinets: Appeared serviceable
Condition of flooring: Appeared serviceable
Condition of sinks and related plumbing: Appeared serviceable
Condition of toilets: Appeared serviceable
Condition of bathtubs and related plumbing: Appeared serviceable
Condition of shower(s) and related plumbing: Appeared serviceable
Condition of ventilation systems: Appeared serviceable
Bathroom ventilation type: Spot fans
Gas supply for laundry equipment present: Yes
240 volt receptacle for laundry equipment present: No

35) At the time of the inspection it was noted that the bathroom areas were overall in serviceable condition.
Photo
Photo 35-1
Photo
Photo 35-2
Photo
Photo 35-3
Photo
Photo 35-4
Photo
Photo 35-5
Photo
Photo 35-6
Photo
Photo 35-7
Photo
Photo 35-8
Photo
Photo 35-9
Photo
Photo 35-10
Photo
Photo 35-11
Photo
Photo 35-12
Photo
Photo 35-13
Photo
Photo 35-14
Photo
Photo 35-15
Photo
Photo 35-16
Photo
Photo 35-17
Photo
Photo 35-18
Photo
Photo 35-19
Photo
Photo 35-20
Photo
Photo 35-21
Photo
Photo 35-22

36) At the time of the inspection it was noted that the laundry room area was overall in serviceable condition.
Photo
Photo 36-1
Photo
Photo 36-2
Photo
Photo 36-3
 

Interior, Doors and Windows
Return to table of contents

Limitations: The following items are not included in this inspection: security, intercom and sound systems; communications wiring; central vacuum systems; elevators and stair lifts; cosmetic deficiencies such as nail-pops, scuff marks, dents, dings, blemishes or issues due to normal wear and tear in wall, floor and ceiling surfaces and coverings, or in equipment; deficiencies relating to interior decorating; low voltage and gas lighting systems. Any comments made regarding these items are as a courtesy only. Note that the inspector does not evaluate any areas or items which require moving stored items, furnishings, debris, equipment, floor coverings, insulation or similar materials. The inspector does not test for asbestos, lead, radon, mold, hazardous waste, urea formaldehyde urethane, or any other toxic substance. Some items such as window, drawer, cabinet door or closet door operability are tested on a sampled basis. The client should be aware that paint may obscure wall and ceiling defects, floor coverings may obscure floor defects, and furnishings may obscure wall, floor and floor covering defects. If furnishings were present during the inspection, recommend a full evaluation of walls, floors and ceilings that were previously obscured when possible. Determining the cause and/or source of odors is not within the scope of this inspection.
Condition of exterior entry doors: Appeared serviceable
Exterior door material: Wood
Condition of interior doors: Appeared serviceable
Condition of windows and skylights: Appeared serviceable
Condition of walls and ceilings: Appeared serviceable
Wall type or covering: Drywall
Ceiling type or covering: Drywall
Condition of flooring: Appeared serviceable
Condition of concrete slab floor(s): Appeared serviceable
Flooring type or covering: Wood or wood products

37) At the time of the inspection it was noted that the living areas were overall in serviceable condition. Please note that if any interior living areas are visually obstructed by stored items, furniture, or any other items, these area will not be fully evaluate and are excluded from this report.
Photo
Photo 37-1
Photo
Photo 37-2
Photo
Photo 37-3
Photo
Photo 37-4
Photo
Photo 37-5
Photo
Photo 37-6
Photo
Photo 37-7
Photo
Photo 37-8
Photo
Photo 37-9
Photo
Photo 37-10
Photo
Photo 37-11
Photo
Photo 37-12
Photo
Photo 37-13
Photo
Photo 37-14
Photo
Photo 37-15
Photo
Photo 37-16
Photo
Photo 37-17
Photo
Photo 37-18
Photo
Photo 37-19
Photo
Photo 37-20
Photo
Photo 37-21
Photo
Photo 37-22
Photo
Photo 37-23
Photo
Photo 37-24
Photo
Photo 37-25
Photo
Photo 37-26
Photo
Photo 37-27
Photo
Photo 37-28
Photo
Photo 37-29
Photo
Photo 37-30

Your default report footer here...