Property Inspection Report
Client(s): NEW HOME BUYER
Property address: 111 NEW SUBDIVISION ST
SOUTHSIDE GEORGIA
Inspection date: This year

This summary page published on 6/8/2009 5:24:41 PM EDT

Return to report

Concerns are shown and sorted according to these types:
Major DefectCorrection likely involves a significant expense 
Repair/ReplaceRecommend repairing or replacing 
Repair/MaintainRecommend repair and/or maintenance 
Minor DefectCorrection likely involves only a minor expense 
EvaluateRecommend evaluation by a specialist 
MonitorRecommend monitoring in the future 
CommentFor your information 

1) Grounds: - Correct drainage away from foundation to 6" drop over 10 feet per IRC 401.3. Standing water observed

2) Exterior / Foundation: - Paint soffits

3) Exterior / Foundation: - Replace damaged siding on right side This piece was patched, Paint is flaking off

4) Exterior / Foundation: - Replace damaged back door sill and caulk threshold

5) Roof / Attic: - Repair curled shingle and overcut shingles in the valley.

Seal all open toe board nail holes

10) Cooling / Heat Pump: - Air condtioner in attic is malfuntioning. Water is spraying from coil.

Replace damaged foam insulation on refrigerent line

Support refrigerent line

Replace defective safety switch in pan

Complete installation of drain pipe on safety pan to drain outside the structure

11) Fireplaces / Stoves / Chimneys: - Adjust damper to close properly

13) Bathrooms / Laundry / Sinks: - Repair pop up drain assembly in guest bath.

Caulk tub and shower to floor edge.

Plumbing shut off valves are not secured to framing with brackets per standard building practices

14) Interior Rooms / Areas: - Shelving is not screwed to studs properly in:

kitchen pantry, front bedroom closet, side bedroom closet, master closet,
bathroom closet guest bath,