View as PDF

Ron Walker Property Inspections

Website: http://www.reporthost.com/ronwalker
Email: walkerinspections@hotmail.com
Phone: (954) 336-4663
11927 SW 57 Court, Cooper City, FL 33330
Inspector: Ron Walker

Summary Page

Home and Property Inspections since 1998
Inspections performed to educate and protect the buyer
Personally performed over 1,000 inspections
Member of National Association of Certified Home Inspectors(NACHI.org)
Client(s): John Smith
Property address: 1234 NW 56 Street
Hometown USA
Inspection date: Saturday, April 11, 2009

This summary page published on 5/4/2009 7:17:32 PM EDT

Return to report

Concerns are shown and sorted according to these types:
SafetyPoses a risk of injury or death 
Repair/ReplaceRecommend repairing or replacing 
Repair/MaintainRecommend repair and/or maintenance 
Minor DefectCorrection likely involves only a minor expense 
MaintainRecommend ongoing maintenance 
EvaluateRecommend evaluation by a specialist 
CommentFor your information 

1) General Information: - One or more hornet, bee or wasp nests were found at the building exterior. These can pose a safety hazard. A qualified person should remove nests or exterminate as necessary.

3) Grounds: - Self-closing devices on one or more gates used with pool or spa fencing were inoperable, needs to be adjusted and aligned. This is a safety hazard because these devices are intended to control access to the pool or spa, especially for children (i.e. West gate needs adjustment and Northeast gate was inoperable). A qualified person should repair, replace or install as necessary.

Cost estimate: $100
4) Grounds: - End cap on aluminum fence missing (located on fence North side); needs to be replaced to prevent intrusion.

Cost estimate: $10
5) Exterior / Foundation: - One or more minor cracks (1/8 inch or less) were found in the foundation (i.e. Garage flooring). These don't appear to be a structural concern, but recommend sealing them to prevent water infiltration and monitoring them in the future. Numerous products exist to seal such cracks including hydraulic cement, resilient caulks and epoxy sealants.

Cost estimate: $100
7) Roof / Attic: - A very few number of roof tiles i.e. East side of home: need to be repaired/replaced. A qualified roofing contractor should evaluate and make repairs as necessary.

Cost estimate: $200
10) Garage / Carport: - The garage-rear pedestrian door has a damaged door casing at strike plate; needs to be repaired or replaced. A qualified person should evaluate and make repairs as necessary.

Cost estimate: $100
12) Electric: - Some electric receptacles had reverse-polarity wiring, where the hot and neutral wires are reversed (i.e., outlet in attic in master bedroom closet). This is a safety hazard due to the risk of shock. A qualified electrician should evaluate and make repairs as necessary.

Cost estimate: $75
13) Electric: - Batteries in all the smoke alarms should be replaced after taking occupancy, and annually in the future. "Chirping" noises emitted from smoke alarms typically indicate that batteries need replacing. For more information, visit:
http://www.cpsc.gov/cpscpub/pubs/5077.html

14) Electric: - One or more electric receptacles appeared to have no power (i.e., master bathroom). Recommend asking the property owner about this. Switches may need to be operated to make some receptacles energized. If necessary, a qualified electrician should evaluate and make repairs as necessary.

Cost estimate: $150
15) Electric: - GFCI receptacle on South balcony of guest bedroom has no power. A qualified electrician should evaluate and repair as necessary.

Cost estimate: $75
21) Cooling / Heat Pump: - Unable to test air handler #2 (NW upstairs). The flow switch on this unit is "lit" indicating an issue with the main condensate drain for this unit. It should be noted that there was no water in the condensate pan during inspection which could possibly indicate a faulty flow switch. The A/C system may still been under the manufacturer's or builder's warranty. A qualified contractor should evaluate and repair as necessary.

Cost estimate: $400
22) Cooling / Heat Pump: - One or more air filters were dirty. A qualified person should replace filter(s) as necessary. Filters should be checked monthly and maintained as necessary in the future.

24) Kitchen: - One or more faucets were reverse-plumbed, where hot water flows when what should be the cold water faucet is operated, or when the single faucet is set to the cold setting, and visa versa. i.e. Kitchen sink faucet. A qualified plumber or contractor should evaluate and repair as necessary.

Cost estimate: $150
26) Bathrooms / Laundry / Sinks: - The clothes dryer exhaust duct was incomplete in one or more places. Clothes dryers produce large amounts of moisture which should not enter structure interiors. Damage to building components may result. A qualified person should evaluate and make permanent repairs as necessary. For more information, visit:
http://www.cpsc.gov/CPSCPUB/PUBS/5022.html

Cost estimate: $50
27) Bathrooms / Laundry / Sinks: - The sink drain stopper mechanism at location #A, B, Fx2 was inoperable. A qualified person should repair or replace as necessary.

Cost estimate: $150
29) Interior Rooms / Areas: - Bar sink (located upstairs) has leak at trap. A qualified plumber should evaluate and repair as necessary.

Cost estimate: $75
30) Interior Rooms / Areas: - One or more window frames need to be caulked at window sill (i.e., master bedroom).