Property Inspection Report |
| Client(s): |
Prospect Buyer(s) |
| Property address: |
15284 Canon Ln Chino Hills CA 91709-5233 |
| Inspection date: |
3/14/2011 |
This report published on Monday, March 14, 2011 8:47:50 PM PDT
View summary page
Dear customer:
Thank you for choosing REPInspections to perform the following inspection on the property you wish to purchase.
This report is the exclusive property of REPInspection and the individual/s paying for the inspection fee and report. Use of this report by any unauthorized persons is prohibited.
All findings should be made to REPInspections.
This report represents our professional opinion of the condition of the inspected elements of the subject property, determine during a limited time inspection. This inspection was performed, where applicable, in a manner consistent with the standards of the home inspection industry, terms and conditions of the inspection agreement and limitations noted in the inspection agreement. Information contained herein was prepared exclusively for the named client and their authorized representatives.
We have inspected the subject property and must report to you exactly what we found. Because of the age, design and location of the home, we might find some hairline cracks on driveways or walls, see paint peeling off Walls, cracks on tiles, chipped bathtubs or some cracks over windows and doors. These are normal and cosmetic conditions.
While due care was exercised in the performance of this inspection, the company makes no representations or guarantees with respect to latent deficiencies or future conditions as part of the inspection or this report. This report is valid only for a period of thirty (30) days from the date of the inspection. This report, including any attachments, should be reviewed in its entirety. Any questions about the inspection or report should be resolved prior to title transfer.
This inspection report was prepared in a format specifically for the individual/s paying for the inspections fee and report and such transfer does not cover all potential areas of concern a third party may have. This report is transferable only with the consent of the individual/s paying for inspections fee and report and such transfer does not imply any warranty or guarantee regarding the report by inspection firm.
If you have any questions regarding this report, please feel free to call us.
How to Read this Report
This report is organized by the property's functional areas. Within each functional area, descriptive information is listed first and is shown in bold type. Items of concern follow descriptive information.
Concerns are shown and sorted according to these types: | Safety | Poses a risk of injury or death |
 | Repair/Replace | Recommend repairing or replacing |
 | Repair/Maintain | Recommend repair and/or maintenance |
 | Minor Defect | Correction likely involves only a minor expense |
 | Maintain | Recommend ongoing maintenance |
 | Evaluate | Recommend evaluation by a specialist |
 | Serviceable | Item or component is in servicable condition |
 | Comment | For your information |
Wood Destroying Organism Concerns
Concerns relating to wood destroying organisms are shown as follows:
 | Infestation | Evidence of infestation of wood destroying insects or organisms (Live or dead insect bodies, fungal growth, etc.) |
 | Damage | Damage caused by wood destroying insects or organisms (Rot, carpenter ant galleries, etc.) |
 | Conducive conditions | Conditions conducive for wood destroying insects or organisms (Wood-soil contact, shrubs in contact with siding, roof or plumbing leaks, etc.) |
Click here for a glossary of building construction terms.
Contact your inspector if there are terms that you do not understand, or visit the glossary of construction terms at http://www.reporthost.com/glossary.asp
Report number: 0177
Inspector's name: Edward Rodriguez
Structures inspected: Residential
Type of building: Single Family
Age of building: 2008
Property owner's name: Prospect Buyer(s)
Time started: 2:40pm
Time finished: 5:45pm
Inspection Fee: $250.00
Payment method: Check
Present during inspection: Client(s), Property owner(s), Realtor(s)
Occupied: Yes
Weather conditions: Partly cloudy
Temperature: Cool, Warm
Ground condition: Dry
Front of structure faces: West
Main entrance faces: South/West
Foundation type: Slab on grade
The following items are excluded from this inspection: Security system, Irrigation system
1)
Some wall, floor and/or ceiling surfaces were obscured by furniture and/or stored items. Some areas couldn't be evaluated.

Photo 35
|

Photo 36
|

Photo 37
|

Photo 38
|

Photo 39
|

Photo 40
|

Photo 41
|

Photo 42
|

Photo 43
|

Photo 46
|

Photo 47
|

Photo 48
|

Photo 49
|

Photo 50
|

Photo 51
|

Photo 52
|

Photo 57
|

Photo 58
|

Photo 76
|

Photo 77
|
Footing material: Poured in place concrete
Foundation material: Poured in place concrete
Apparent wall structure: Wood frame
Wall covering: Stucco
Driveway material: Poured in place concrete
Sidewalk material: Poured in place concrete
Exterior door material: Wood panel, Glass panel
2)

Minor cracks, deterioration and/or damage were found in one or more areas of the stucco siding. A qualified contractor should evaluate and make repairs and/or replace stucco siding as necessary.

Photo 7
|

Photo 8
|

Photo 9
|

Photo 10
|

Photo 11
|

Photo 13
|

Photo 19
|
|
3)
One or more downspouts have no extensions, or have extensions that are ineffective. This can result in water accumulating around the structure's foundation, or in basements and crawl spaces if they exist. Accumulated water is a conducive condition to wood destroying insects and organisms, and may also cause the foundation to settle and possibly fail over time. Repairs should be made as necessary, such as installing or repositioning splash blocks, or installing and/or repairing tie-ins to underground drain lines, so rain water is carried at least several feet away from the structure to soil that slopes down and away from the structure.
4)
One or more soffit vent screens are blocked by paint, stucco, insulation or debris. This can reduce air flow through the attic, reduce the life of the roof surface because of high temperatures, and/or increase the moisture content in the attic. Repairs should be made as necessary, such as cleaning paint from screens, replacing screens, and/or moving insulation so vents are unobstructed.

Photo 25
|
|
5)
Gaps exist at one or more openings around the exterior, such as those where outside faucets, refrigerant lines, and/or gas supply pipes penetrate the exterior. Gaps should be sealed as necessary to prevent moisture intrusion and entry by vermin.

Photo 4
|
|
6)
Vegetation such as trees, shrubs and/or vines are in contact with or less than one foot from the structure's exterior. Vegetation can serve as a conduit for wood destroying insects and may retain moisture against the exterior after it rains. Vegetation should be pruned and/or removed as necessary to maintain a one foot clearance between it and the structure's exterior.

Photo 16
|

Photo 17
|
7)
Minor cracks were found in the driveway. However they don't appear to be a structural concern and no trip hazards were found. No immediate action is recommended, but the client(s) may wish to have repairs made or have cracked sections replaced for aesthetic reasons.

Photo 20
|
|
Roof inspection method: Viewed from eaves on ladder, Viewed from ground with binoculars
Roof type: Gable, Cross-hipped
Roof covering: Concrete tile
Estimated age of roof: 2008
Gutter & downspout material: Aluminum
Roof ventilation: Adequate
8)
Because of the roof covering type and/or the configuration of the roof, the inspector was unable to traverse the roof and wasn't able to fully evaluate the entire roof.

Photo 23
|

Photo 15
|

Photo 21
|

Photo 22
|

Photo 24
|
|
9)


The auto-reverse mechanism on the vehicle door opener is inoperable or requires too much force to activate. This is a safety hazard, especially for small children. A qualified contractor should evaluate and repair as necessary. For more information on garage door safety issues, visit:
http://www.cpsc.gov/cpscpub/pubs/523.html
http://www.ohdstl.com/safety.html

Photo 32
|

Photo 31
|

Photo 33
|
|
10)

The infrared "photo eye" devices that trigger the vehicle door opener's auto-reverse feature are located higher than 4 to 6 inches from the floor. This is a potential safety hazard. A qualified contractor should relocate these devices so they're 4 to 6 inches from the floor. For more information on garage door safety issues, visit:
http://www.cpsc.gov/cpscpub/pubs/523.html
http://www.ohdstl.com/safety.html

Photo 30
|

Photo 34
|
11)

The vehicle door is difficult or unable to open or close. Vehicle doors should open and close smoothly and easily. A qualified contractor should evaluate and make repairs as necessary.

Photo 105
|
|
12)
The interior perimeter of the garage is excluded from this inspection due to lack of access from stored items.

Photo 27
|

Photo 28
|

Photo 29
|
|
Inspection method: Partially traversed
Roof structure type: Trusses
Ceiling structure: Trusses
Insulation material: Fiberglass loose fill, Fiberglass roll or batt
Insulation depth: 12"
Insulation estimated R value: R30
13)
Serviceable and adequate Insulation.
14)
Some attic areas were inaccessible due to lack of permanently installed walkways, the possibility of damage to insulation, low height and/or stored items. These areas are excluded from this inspection.

Photo 66
|

Photo 67
|

Photo 68
|

Photo 71
|
Primary service type: Underground
Primary service overload protection type: Circuit breakers
Service amperage (amps): 200
Service voltage (volts): 120/240
Location of main service switch: North
Location of sub panels: Garage
Location of main disconnect: Breaker at bottom of main service panel
Service entrance conductor material: Aluminum
System ground: Copper
Main disconnect rating (amps): 200
Branch circuit wiring type: Non-metallic sheathed
Smoke detectors present: No
15)

One or more screws are missing from the subpanel cover and should be replaced. Because energized wiring may exist behind the holes with the missing screws, recommend that a qualified, licensed electrician replace these screws, or that care be taken to ensure that the new screws do not come in contact with wiring inside the panel when they are installed. Stock screws from the panel manufacturer should be used, or their equivalent.

Photo 81
|

Photo 82
View with the subpanel cover removed. (Wiring appears to be in serviceable condition)
|
16)
Serviceable

Photo 83
|

Photo 84
View with the main service panel cover removed. (Wiring appears to be in serviceable condition)
|
Estimated age: Not visible
Type: Tank
Energy source: Natural gas
Capacity (in gallons): Not visible
Manufacturer: Not visible
Model: Not visible
Water temperature (degrees Fahrenheit): 114.2F
17)
A permanently installed insulated jacket is installed on the water heater. It obscures the manufacturer's information label and most of the water heater. The inspector was unable to fully evaluate the water heater.

Photo 80
|
|
18)
Water temperature (degrees Fahrenheit): 114.2F

Photo 61
|
|
Estimated age: 2007 / 2008
Primary heating system energy source: Natural gas
Primary heat system type: Forced air
Primary A/C energy source: Electric
Primary Air conditioning type: Split system
Distribution system: Flexible ducts
Manufacturer: International Comfort/Comfortmaker
Model: Heating# N8MPL100F20B2 & N8MPL075F16B2 / AC# N2A348AKA300 & N2A348AKA300
Filter location: Behind return air grill
Last service date: Unknown
19)


The last service date of these systems appear to be more than one year ago, or the inspector was unable to determine the last service date. The client(s) should ask the property owner(s) when they were last serviced. If unable to determine the last service date, or if these systems were serviced more than one year ago, a qualified heating and cooling contractor should inspect, clean, and service these systems, and make repairs if necessary. For safety reasons, and because these systems are fueled by gas or oil, this servicing should be performed annually in the future. For more information visit:
http://www.cpsc.gov/CPSCPUB/PREREL/prhtml05/05017.html

Photo 72
|

Photo 73
|

Photo 74
|

Photo 75
|
20)
No drip leg is installed on one or more furnace or boiler gas supply lines. Drip legs are intended to trap oil, scale, water condensation and/or debris from the gas supply lines before they reach and damage the furnace or boiler components. A qualified contractor should install a drip leg as per standard building practices. (Note that depending on the quality of the gas being delivered in some municipalities, the installation of a drip leg or dirt leg may not be required by local officials.)

Photo 102
|
|
21)

The last service date of these systems appear to be more than one year ago, or the inspector was unable to determine the last service date. The client(s) should ask the property owner(s) when they were last serviced. If unable to determine the last service date, or if these systems were serviced more than one year ago, a qualified heating and cooling contractor should inspect, clean, and service these systems, and make repairs if necessary. This servicing should be performed annually in the future.

Photo 93
|

Photo 94
|

Photo 95
|

Photo 96
|
22)
Vegetation such as trees, shrubs and/or vines are too close to one or more outdoor condensing units. Standard building practices require that there be at least 12 inches of clearance on all sides and at least four to six feet above. Inadequate clearances around the condensing unit can result in reduced efficiency, increased energy costs and/or damage to equipment. Vegetation should be pruned and/or removed as necessary to maintain these clearances.

Photo 97
|
|
Water pressure (psi): 50psi
Location of main water shut-off valve: North wall inside the garage.
Location of main water meter: West
Location of main fuel shut-off: North
Water service: Public
Service pipe material: Copper
Supply pipe material: Copper
Vent pipe material: Plastic
Drain pipe material: Plastic
Waste pipe material: Plastic
23)

One or more waste pipe cleanouts have no cap installed. This is a safety hazard because sewer gases may vent into the structure. A qualified plumber should install a caps where missing.

Photo 14
|
|
24)
Neither the clothes washer nor dryer were operated or evaluated. They are excluded from this inspection.

Photo 56
|
|
25)

Photo 100
Water pressure (psi)
|

Photo 98
Main water shut-off valve: North wall inside the garage.
|

Photo 101
Main water meter.
|

Photo 99
Main fuel shut-off.
|
Fireplace type: Metal prefabricated
Chimney type: Metal
26)
Serviceable

Photo 64
|

Photo 92
|
27)


One or more electric receptacles and/or the boxes they are installed in are loose and/or not securely anchored. Wire conductors may be damaged due to repeated movement and/or tension on wires, or insulation may be damaged. This is a safety hazard due to the risk of shock and fire. A qualified electrician should evaluate and repair as necessary.

Photo 89
|

Photo 90
|

Photo 91
|
|
28)
All appliances appear to be serviceable.

Photo 85
|

Photo 86
|

Photo 87
|

Photo 88
|
29)


The inspector was unable to determine if ground fault circuit interrupter (GFCI) protection is installed for the jetted tub's electric supply due to lack of access to the equipment below the tub. If no GFCI protection is installed, then this is a safety hazard due to the risk of shock. A qualified contractor and/or electrician should evaluate and install GFCI protection if none exists. If necessary, modifications should be made to allow access to the GFCI device for periodic evaluation and to reset it when it trips.

Photo 104
|
|
30)

One or more electric receptacles are broken or damaged. This is a safety hazard due to the risk of fire and shock. A qualified electrician should replace them as necessary.

Photo 59
It appears there is a broken and/or jammed ground prong located in the receptacle. (Master bathroom)
|

Photo 60
(Master bathroom)
|
31)
Caulk is missing or deteriorated above one or more bathtubs, where the tub surround meets the tub. It should be replaced where deteriorated and/or applied where missing to prevent water intrusion and damage to the wall structure.

Photo 79
|
|
32)
Caulk is missing or deteriorated around the base of one or more bathtub spouts. It should be replaced where deteriorated and/or applied where missing to prevent water intrusion and damage to wall structures.

Photo 78
|
|
33)
Recommend cleaning and sealing grout in one or more showers now and in the future as necessary to prevent staining and to improve waterproofing.

Photo 44
|

Photo 45
|
34)
One or more toilets have no water supply and could not be fully evaluated. The shut-off valve(s) may be turned off, or repairs may be necessary. The client(s) should ask the property owner(s) about this, and have a qualified plumber evaluate and repair if necessary.

Photo 62
|

Photo 63
|
35)
Recommend cleaning and sealing grout in countertops located in the laundry room now and in the future as necessary to prevent staining and to improve waterproofing.

Photo 53
|

Photo 54
|

Photo 55
|
|
1.1. A Home Inspection is a non-invasive, visual examination of a residential dwelling, performed for a fee, which is designed to identify observed material defects within specific components of said dwelling. Components may include any combination of mechanical, structural, electrical, plumbing, or other essential systems or portions of the home, as identified and agreed to by the Client and Inspector, prior to the inspection process.
I. A home inspection is intended to assist in evaluation of the overall condition of the dwelling. The inspection is based on observation of the visible and apparent condition of the structure and its components on the date of the inspection, and not the prediction of future conditions.
II. A home inspection will not reveal every concern that exists or ever could exist, but only those material defects observed on the day of the inspection.
III. A home inspection can include a survey and/or analysis of energy flows and usage in a residential property if the client requests it.
1.2. A Material Defect is a condition of a residential real property, or any portion of it, that would have a significant, adverse impact on the value of the real property, or that involves an unreasonable risk to people on the property. The fact that a structural element, system or subsystem is near, at or beyond the end of the normal useful life of such a structural element, system or subsystem is not by itself a material defect.
1.3. An Inspection Report shall describe and identify, in written format, the inspected systems, structures, and components of the dwelling, and shall identify material defects observed. Inspection reports may contain recommendations regarding conditions reported or recommendations for correction, monitoring or further evaluation by professionals, but this is not required.
A complete copy of the STANDARDS OF PRACTICE we adhere to can be found at the following link: http://www.nachi.org/sop.htm