Property Inspection Report
Client(s): Inna Sablina
Property address: 10400 SE Cook Ct
Milwaukie, OR 97222
Space # 41
Inspection date: Tuesday, December 23, 2009
This report published on 12/23/2009 4:55:54 PM PST

View summary page

This report is the exclusive property of this inspection company and the client(s) listed in the report title. Use of this report by any unauthorized persons is prohibited.

 
How to Read this Report
This report is organized by the property's functional areas.  Within each functional area, descriptive information is listed first and is shown in bold type.  Items of concern follow descriptive information.
Concerns are shown and sorted according to these types:
SafetyPoses a risk of injury or death 
Major DefectCorrection likely involves a significant expense 
Repair/ReplaceRecommend repairing or replacing 
Repair/MaintainRecommend repair and/or maintenance 
Minor DefectCorrection likely involves only a minor expense 
MaintainRecommend ongoing maintenance 
EvaluateRecommend evaluation by a specialist 
MonitorRecommend monitoring in the future 
CommentFor your information 

Click here for a glossary of building construction terms.  Contact your inspector if there are terms that you do not understand, or visit the glossary of construction terms at http://www.reporthost.com/glossary.asp

Table of Contents
General information
Exterior
Roof
Electric service
Heating and cooling
Plumbing and laundry
Crawl space
Kitchen
Bathrooms
Water heater
 
General information Return to table of contents
Type of building: Manufactured homeRedman Ranchero
Age of building: 16
Time started: 12/23/09
Time finished: 12/23/09
Inspection Fee: 275
Payment method: Check
Present during inspection: Client(s), Realtor(s)
Occupied: No
Weather conditions: Fog
35: Cold
Front of structure faces: East
Foundation type: Steel on block
 
Exterior Return to table of contents
Foundation material: Steel frame on concrete block piers
Apparent wall structure: Wood frame
Wall covering: Composition wood panels
Driveway material: Asphalt
Sidewalk material: Poured in place concrete
Exterior door material: Solid core steel
1) Trip hazard(s) exist at stairs due to non-uniform riser heights. Standard building practices call for riser heights not to vary more than 3/8 inch on a flight of stairs. At a minimum, the client(s) should be aware of this hazard, especially when guests who are not familiar with the stairs are present. Ideally a qualified contractor should evaluate and repair or replace stairs so all riser heights are within 3/8 inch of each other.

Photo 7  

Photo 9  

Photo 25  
varied riser heights
 

2) Gaps larger than four inches were found in one or more guardrails. This is a safety hazard, especially for small children. A qualified contractor should make modifications as necessary so gaps in guardrails do not exceed four inches. For example, installing additional balusters or railing components.

Photo 10  
Railing gap is larger than 4 "
 

3) One or more exterior electric receptacles aren't waterproof or rated for use in wet areas. This is a safety hazard due to the risk of shock and fire. Repairs should be made as necessary, and by a qualified electrician if necessary, so all exterior receptacles are waterproof as per standard building practices.

Photo 31  
Broken exterior outlet cover.
 

4) One or more outside faucets are missing backflow prevention devices. These devices reduce the likelihood of polluted or contaminated water entering the potable water supply. This condition can occur when an outside faucet is left in the "on" position with a hose connected and the sprayer head turned off. When pressure in the system fluctuates, water can be drawn back into the water supply pipes from the house. If a chemical sprayer is being used with the hose, those chemicals can enter the water supply pipes.

Recommend installing backflow prevention devices on all exterior hose bibs where missing. They are available at most home improvement stores and are easily installed. For more information, visit:
http://edis.ifas.ufl.edu/AE113

5) Soil is in contact with or less than six inches from siding and/or trim. This is a conducive condition for wood destroying insects and organisms. Wood siding and/or trim is rotten in some areas as a result. A qualified contractor should evaluate and repair as necessary, replacing all rotten wood. Also, the soil should be graded and/or removed as necessary so there are at least six inches of space between the siding and trim and the soil below.

Photo 16  
Door is missing hardware to latch shut

Photo 19  
Trim board deteriorated/ soil matter to close to material

Photo 78  
Moisture damage to skirting on South side of crawl space
 

6) Recommend deck ledger board be fastened with appropriate lag screw bolts

Photo 84  
Undersized nails supporting deck ledger board. (2x6 PT material
 

7) Recommend removal of wood debris under home

Photo 76  
Wood debris in crawl space
 

8) Soil is in contact with or less than six inches from siding and/or trim. This is a conducive condition for wood destroying insects and organisms. Soil should be graded and/or removed as necessary so there are at least six inches of space between the siding and trim and the soil below.
9) Caulk is missing or deteriorated in some areas and should be replaced and/or applied where necessary. For more information on caulking, visit:
The Ins and Outs of Caulking.

Photo 18  
Hardy plank loose/ attach and caulk
 

10) Stair tread is sloped toward house. Recommend tread slope that moves water away from siding and home

Photo 4  

Photo 5  

11)   North side deck/porch has open area of skirting on the west side/backyard. The skirting on the house is also missing in this same area.Recommend installing skirting to block animals from entering crawl space of home.

Photo 81  
Open area at West side of home

Photo 88  
Missing skirting at West side of Deck

12)  

Photo 11  
Portions of the deck/porch have split and deteriorated wood that has been painted

Photo 12  
Moss on South side entrance carpet due to moisture.

Photo 14  
Broken bubbler from gutter downspout pipe

Photo 15  
Deteriorated wood

Photo 17  
Deteriorated wood

Photo 26  
Gap and moisture on shed sheathing

Photo 27  
Shed sheathing
 

13)  

Photo 89  
Locked large shed

Photo 90  
Paint on edge of windows

Photo 91  
Missing hardware to access door

Photo 92  
Broken bubbler
 
Roof Return to table of contents
Roof inspection method: Traversed
Roof type: Gable
Roof covering: Asphalt or fiberglass composition shingles
Estimated age of roof: 16
Gutter & downspout material: Steel
Roof ventilation: Adequate
14)

Photo 68  
Moss on West side of roof

Photo 69  
Gutter filled with debris on south side of roof

15) One or more sections of roof flashing are deteriorated and/or rusted. Leaks may occur as a result. A qualified roofing contractor should evaluate and replace flashing where necessary.

Photo 64  
Rusted drip edge
 

16) One or more composition shingles have raised, most likely due to nails that have loosened. Leaks may occur as a result. A qualified roofing contractor should evaluate and make repairs as necessary, such as reseating nails.

Photo 71  
Elevated shinge
 

17) Vent to short / snowfall could block and create plumbing issues.

Photo 70  
Short vent pipe on South/west side of roof. Snow could block vent
 

18) Recommend repairs to roof on smaller shed .Shingles missing

Photo 21  
Shed roofing material missing.

Photo 22  
Shed roofing shingles missing. Wood fascia missing

Photo 26  
Gap and moisture on shed sheathing

Photo 27  
Shed sheathing

19)  

Photo 73  
North side of roof

Photo 74  
South side of roof

Photo 75  
South side of roof
 
 
Electric service Return to table of contents
Primary service type: Underground
Primary service overload protection type: Circuit breakers
Service amperage (amps): 200
Service voltage (volts): 120/240
Location of main service switch: Utility room
Location of main disconnect: Breaker at bottom of main service panel
Service entrance conductor material: Aluminum
System ground: Ground rod(s) in soil
Main disconnect rating (amps): 200
Branch circuit wiring type: Copper
Smoke detectors present: Yes
20) Recommend replacing incorrect cover plate

Photo 38  
Incorrect electrical cover plate for dryer.
 

21)  

Photo 33  
200 amp electrical service panel/ breakers
 

22)  

Photo 3  
200 amp service meter
 
 
Heating and cooling Return to table of contents
Estimated age:
Primary heat system type: Heat pump
Manufacturer: Carrier
Model: 38YKCO24300
Filter location: In return air duct above furnace
23) The estimated useful life for most forced air furnaces is 15 to 20 years. This furnace appears to be approaching this age and may need replacing at any time. Recommend budgeting for a replacement in the near future.

Photo 34  

Photo 35  

Photo 36  

Photo 37  
Interior of heating motor unit with dirt build-up

24) The estimated useful life for most heat pumps is 15 to 20 years. This heat pump appears to be approaching this age and may need replacing at any time. Recommend budgeting for a replacement in the near future.

Photo 23  
Heat pump covered with icy frost
 

25) No filter is visible for the heating/cooling system. As a result, unfiltered air will flow through the system, and the heating/cooling equipment life and the indoor air quality may be reduced. Correctly sized filter(s) should be installed. If necessary, guides or retaining devices should be installed or repaired so filter(s) are securely anchored and gaps around edges are minimized.
26) The last service date of this system appears to be more than one year ago, or the inspector was unable to determine the last service date. The client(s) should ask the property owner(s) when it was last serviced. If unable to determine the last service date, or if this system was serviced more than one year ago, a qualified heating and cooling contractor should inspect, clean, and service this system, and make repairs if necessary. This servicing should be performed annually in the future.
27) Air handler filter(s) should be checked monthly in the future and replaced or washed as necessary.
28) The outdoor air temperature was below 60 degrees Fahrenheit during the inspection. Because of this, the inspector was unable to operate and fully evaluate the cooling system.
 
Plumbing and laundry Return to table of contents
Water pressure (psi): 80
Location of main water shut-off valve: Front of home
Water service: Public
Service pipe material: Galvanized steel
Supply pipe material: CPVC, Polybutylene
Vent pipe material: Plastic
Drain pipe material: Plastic
Waste pipe material: Plastic
29) The water supply pressure is 80 psi. Pressures above 80 psi may void warranties for some appliances such as water heaters or washing machines. Flexible supply lines to washing machines are more likely to burst with higher pressures. Typically the pressure cannot be regulated at the water meter. Recommend having a qualified plumber evaluate and make modifications to reduce the pressure below 80 psi. Installing a pressure reducing valve on the main service pipe is a common solution to this problem. If one exists, then it should be adjusted for lower pressures.

Photo 13  
Main water shut-off
 

30) No clothes dryer exhaust duct is installed. Clothes dryers produce large amounts of moisture which should not enter structure interiors. Damage to building components may result. A rigid or semi-rigid metal exhaust duct should be installed as per standard building practices, and by a qualified contractor if necessary. For information, visit:
http://www.cpsc.gov/CPSCPUB/PUBS/5022.html

Photo 39  
Dryer exhaust pipe missing
 
 
Crawl space Return to table of contents
Inspection method: Traversed
Insulation material underneath floor above: Fiberglass roll or batt
Pier or support post material: Concrete
Beam material: Steel
Floor structure above: Solid wood joists
Vapor barrier present: Yes
31)   Homes belly wrap open in several areas.

Photo 77  
Open belly wrap

Photo 79  
Open belly wrap in crawl space

Photo 80  
Open belly wrap under home

Photo 82  
Open wrap at main electrical service entrance
 
Kitchen Return to table of contents

32) One or more electric receptacles that serve countertop surfaces within six feet of a sink appear to have no ground fault circuit interrupter (GFCI) protection. This is a safety hazard due to the risk of shock. A qualified electrician should evaluate to determine if GFCI protection exists, and if not, repairs should be made so that all receptacles that serve countertop surfaces within six feet of sinks have GFCI protection. For example, install GFCI receptacles or circuit breaker(s) as needed.

Photo 40  
Bad ground in kitchen receptacle next to sink
 

33) The dishwasher drain line is not configured with a "high loop" or "air gap". A high loop is created by routing the drain line up to the bottom surface of the counter top above, and securely fastening it to that surface. It is meant to prevent water from siphoning out of the dishwasher, and to prevent water from the sink drain or food disposal from entering the dishwasher. Some dishwashers have a built-in high loop where one is not required to be configured in the drain line. The clients should try to determine if a high loop is required for this brand and model of dishwasher (review installation instructions, etc.). If one is required, or it cannot be determined if one is not required, then a qualified contractor should install a high loop as per standard building practices.

Also, no "air gap" is installed. Air gaps are another device meant to prevent water from the sink drain or food disposal from entering the dishwasher. These are required in some municipalities for new construction and when remodeling. The client(s) should consult with a qualified contractor to determine if an air gap should be installed.

Photo 45  
Drain line from dishwasher missing high loop before connection to sink waste line.
 

34) The under-sink food disposal is inoperable. A qualified plumber or contractor should evaluate and repair or replace the food disposal as necessary.

Photo 43  
Presence of water to cabinet floor board for leak.

Photo 44  
Leaking waste line on garbage disposal unit
 
Bathrooms Return to table of contents

35) One or more electric receptacles appear to have no power. Recommend asking the property owner(s) about this. Switches may need to be operated to make some receptacles energized. If necessary, a qualified electrician should evaluate and make repairs as necessary.

Photo 32  
Inoperable receptacle in master bath
 

36) One or more sink stopper mechanisms are missing, or need adjustment or repair. Stopper mechanisms should be installed where missing and/or repairs should be made so sink stoppers open and close easily.

Photo 51  

Photo 57  
Caulking missing around sink

37) Hall bath surround loose.

Photo 54  
bath tub surround not secured to wall
 

38) Shower head pipe not secured to shower wall.

Photo 61  
Loose shower head pipe in master bath
 

39) Caulk is missing or deteriorated along the base of one or more bathtubs, where flooring meets the tub. It should be replaced where deteriorated and/or applied where missing to prevent water intrusion and damage to the floor structure.

Photo 55  
caulking missing/repairs needed
 

40) Caulk is missing or deteriorated above one or more bathtubs, where the tub surround meets the tub. It should be replaced where deteriorated and/or applied where missing to prevent water intrusion and damage to the wall structure.

Photo 56  
Caulk missing on the upper edge of tub surround
 

41) Caulk is missing and/or deteriorated where countertops meet backsplashes in wet areas, such as around sinks. Caulk should be replaced where deteriorated and/or applied where missing to prevent water damage.

Photo 47  
Exposed caulking around hall bath sink

Photo 57  
Caulking missing around sink

Photo 58  
Caulking missing/repairs needed
 

42) Minor damage and/or deterioration was found at countertops in one or more areas. The client(s) should evaluate and consider having repairs made, and/or countertops replaced where necessary.
43)  

Photo 48  

Photo 50  
Open area around toilet water supply line

Photo 61  
Loose shower head pipe in master bath
 
 
Water heater Return to table of contents
Type: Tank
Energy source: Electricity
Capacity (in gallons): 50
Manufacturer: Interthrem
Model: TM 0393826550
Water temperature (degrees Fahrenheit): 120
44)  

Photo 93  

Photo 94  

45)   Functions properly
 

Photo 6  

Photo 8  

Photo 20  
West side/back of home

Photo 24  
Heat pump serial and model plate

Photo 28  
Drive-way side entrance and deck

Photo 29  
Loose trim board at South side porch entrance skirting area

Photo 41  
Inoperable receptacle in master bathroom

Photo 42  
Open neutral on receptacle on east wall of dining/den room

Photo 46  
Open area around abs drain waste line

Photo 49  

Photo 52  
High/elevated area on floor in hall bath hallway

Photo 53  
High/elevated area in living room area close to the kitchen wall

Photo 59  
Open area around waste line covered with mesh which opens area to insect/air infiltration

Photo 60  
Heating thermostate

Photo 62  
High/elevated area in living room

Photo 63  
Damaged sink in hall bath

Photo 65  

Photo 66  

Photo 67  

Photo 72  
Large shed

Photo 83  
Underside of deck/ porch on the North side of home

Photo 85  
Dryer vent missing

Photo 86  
Opening

Photo 87  

 