Website: http://www.ocalahomeinspection.com
Email: Mjvanek1@aol.com
Phone: (352) 361-8065
FAX: (352) 288-3764
PO Box 4891  
Ocala, FL 
34478
Inspector: Michael Vanek

 

Professional Home Inspection
Client(s): Buyer
Property address: 7089 SW 35th
Gainsville, FL
Inspection date: Friday, June 15, 2007
This report published on 6/15/2007 9:48:41 PM EDT

View summary page

This report is the exclusive property of this inspection company and the client(s) listed in the report title. Use of this report by any unauthorized persons is prohibited.

 
How to Read this Report
This report is organized by the property's functional areas.  Within each functional area, descriptive information is listed first and is shown in bold type.  Items of concern follow descriptive information. Concerns are shown and sorted according to these types:
SafetyPoses a risk of injury or death 
Repair/ReplaceRecommend repairing or replacing 
Repair/MaintainRecommend repair and/or maintenance 
MaintainRecommend ongoing maintenance 
CommentFor your information 

Click here for a glossary of building construction terms.  Contact your inspector if there are terms that you do not understand, or visit the glossary of construction terms at http://www.reporthost.com/glossary.asp

Table of Contents
General information
Exterior
Roof
Attached garage
Electric service
Heating and air conditioning
Interior rooms
 
General information Return to table of contents
Payment & Billing: Paid at Time of Inspection, Paid Cash$275.00
Structures inspected: Home
Present during inspection: Buyer
Occupied: No
Age of building: New
Type of building: Single family


1) Recomended to the buyer to have the sprinklers raised and adjusted to cover all areas.
 
Exterior Return to table of contents
Footing material: Poured in place concrete
Foundation material: Concrete block
Apparent wall structure: Wood frame
Wall covering: Cement-based panels & Stucco
Driveway material: Poured in place concrete
Sidewalk material: Poured in place concrete
Exterior door material: Glass panel
2) The is some soffit missing around the outside of the fireplace area. Repair or replace.
 
Roof Return to table of contents
Number of Remaing Years of Life: 30 year roof
Roof type: Hipped
Roof covering: Asphalt or fiberglass composition shingles
Estimated age of roof: Few Months
Gutter & downspout material: None
Roof ventilation: Adequate
 
Attached garage Return to table of contents

3) No hatch is installed over the attic access. A 1 hour fire-rated hatch (e.g. 5/8" Type X sheetrock) should be installed to slow or prevent the spread of fire from the attached garage to interior living spaces.
4) There are several cracks in the garage floor from settlement. No action required.
 
Electric service Return to table of contents
Primary service type: Underground
Primary service overload protection type: Circuit breakers
Service amperage (amps): 150
Service voltage (volts): 120-240
Location of sub panels: Laundry room
Location of main disconnect: Breaker at top of main service panel
Main disconnect rating (amps): 150
Smoke detectors present: Yes
5) The outlets in the master bathroom do not work. Repair or replacement.
 
Heating and air conditioning Return to table of contents
Heating system energy source: Electric
Heat system type: Heat pump
A/C energy source: Electric
Air conditioning type: Heat pump
Distribution system: Flexible ducts
Filter location: Behind return air grill
6) Recommend that this system be inspected, cleaned, serviced and repaired if necessary by a qualified heating and cooling technician every two years in the future.
7) This system is equpped with mechanical pleated filter(s). Recommend replacing them every 7 to 12 months in the future if the thermostat's fan position is set to "Auto", or monthly if it's set to "On".
 
Interior rooms Return to table of contents

8) The hall shower light does not work.

Photo 3  

9) There is a large seam showing in the back bedroom. Recomended repairing or replace.

Photo 4  

10) There are several swinging doors not working properly and missing hardware. Repair or replace.

Photo 6  

11) The outlet on the hall bath wall is loose and needs reattached.

Photo 2  

12) The window left of the fireplace is hard to open and not working properly.
13) The upstairs bath cabinet has water stains inside the cabinet.
14) There is a missing towel bar in the hall bathroom.
15)   The back bedroom window sill is missing and needs installed.

Photo 5  

 
1. INSPECTOR agrees to perform a visual inspection of the home/building and to provide CLIENT with a written inspection report identifying the defects that INSPECTOR both observed and deemed material. INSPECTOR may offer comments as a courtesy, but these comments will not comprise the bargained-for report. The report is only supplementary to the sellers disclosure.
2. Unless otherwise inconsistent with this Agreement or not possible, INSPECTOR agrees to perform the inspection in accordance to the current Standards of Practice of the National Association of Certified Home Inspectors posted at http://www.nachi.org/sop.htm. CLIENT understands that these standards contain certain limitations, exceptions, and exclusions.
3. The inspection and report are performed and prepared for the use of CLIENT, who gives INSPECTOR permission to discuss observations with real estate agents, owners, repairpersons, and other interested parties. INSPECTOR accepts no responsibility for use or misinterpretation by third parties. INSPECTORS inspection of the property and the accompanying report are in no way intended to be a guarantee or warranty, express or implied, regarding the future use, operability, habitability or suitability of the home/building or its components. Any and all warranties, express or implied, including warranties of merchantability and fitness for a particular purpose, are expressly excluded by this Agreement.

4. INSPECTOR assumes no liability for the cost of repair or replacement of unreported defects or deficiencies either current or arising in the future. CLIENT acknowledges that the liability of INSPECTOR, its agents, employees, for claims or damages, costs of defense or suit, attorneys fees and expenses and payments arising out of or related to the INSPECTORS negligence or breach of any obligation under this Agreement, including errors and omissions in the inspection or the report, shall be limited to liquidated damages in an amount equal to the fee paid to the INSPECTOR, and this liability shall be exclusive. CLIENT waives any claim for consequential, exemplary, special or incidental damages or for the loss of the use of the home/building even if the CLIENT has been advised of the possibility of such damages. The parties acknowledge that the liquidated damages are not intended as a penalty but are intended (i) to reflect the fact that actual damages may be difficult and impractical to ascertain; (ii) to allocate risk among the INSPECTOR and CLIENT; and (iii) to enable the INSPECTOR to perform the inspection at the stated fee.

5. INSPECTOR does not perform engineering, architectural, plumbing, or any other job function requiring an occupational license in the jurisdiction where the inspection is taking place, unless the inspector holds a valid occupational license, in which case he/she may inform the CLIENT that he/she is so licensed, and is therefore qualified to go beyond this basic home inspection, and for additional fee, perform additional inspections beyond those within the scope of the basic home inspection. Any agreement for such additional inspections shall be in a separate writing.

6. In the event of a claim against INSPECTOR, CLIENT agrees to supply INSPECTOR with the following: (1) Written notification of adverse conditions within 14 days of discovery, and (2) Access to the premises. Failure to comply with the above conditions will release INSPECTOR and its agents from any and all obligations or liability of any kind.
7. The parties agree that any litigation arising out of this Agreement shall be filed only in the Court having jurisdiction in the County in which the INSPECTOR has its principal place of business. In the event that CLIENT fails to prove any adverse claims against INSPECTOR in a court of law, CLIENT agrees to pay all legal costs, expenses and fees of INSPECTOR in defending said claims.
8. If any court declares any provision of this Agreement invalid or unenforceable, the remaining provisions will remain in effect. This Agreement represents the entire agreement between the parties. All prior communications are merged into this Agreement, and there are no terms or conditions other than those set forth herein. No statement or promise of INSPECTOR or its agents shall be binding unless reduced to writing and signed by INSPECTOR. No change or modification shall be enforceable against any party unless such change or modification is in writing and signed by the parties. This Agreement shall be binding upon and enforceable by the parties and their heirs, executors, administrators, successors and assignees. CLIENT shall have no cause of action against INSPECTOR after one year from the date of the inspection.
9. Payment of the fee to INSPECTOR (less any deposit noted above) is due upon completion of the on-site inspection. The CLIENT agrees to pay all legal and time expenses incurred in collecting due payments, including attorneys fees, if any. If CLIENT is a corporation, LLC, or similar entity, the person signing this Agreement on behalf of such entity does personally guaranty payment of the fee by the entity.
CLIENT HAS CAREFULLY READ THE FOREGOING, AGREES TO IT, AND ACKNOWLEDGES RECEIPT OF A COPY OF THIS AGREEMENT.