| Professional Home Inspection | |
| Client(s): | Monte Buky & Cindy |
| Property address: | 4912 SE 32 Court Ocala, FL 34480 |
| Inspection date: | Wednesday, September 05, 2007 |
This report is the exclusive property of this inspection company and the client(s) listed in the report title. Use of this report by any unauthorized persons is prohibited.
![]() | Safety | Poses a risk of injury or death |
![]() | Major defect | Correction likely involves a significant expense |
![]() | Repair/Replace | Recommend repairing or replacing |
![]() | Repair/Maintain | Recommend repair and/or maintenance |
![]() | Minor defect | Correction likely involves only a minor expense |
![]() | Maintain | Recommend ongoing maintenance |
![]() | Evaluate | Recommend evaluation by a specialist |
![]() | Comment | For your information |
Click here for a glossary of building construction terms.
Contact your inspector if there are terms that you do not understand, or visit the glossary of construction terms at http://www.reporthost.com/glossary.aspTable of Contents
General information
Exterior
Roof
Attached garage
Electric service
Water heater
Heating and air conditioning
Attic
Plumbing and laundry
Interior rooms
| General information | Return to table of contents |
Recomended having gutters installed on front and back to direct water from the entrance.
| Exterior | Return to table of contents |
The end cap on the clothes dryer exhaust duct is damaged. Their purpose is to prevent air from entering the house through the clothes dryer, save energy, and keep out birds, rodents and bugs. Birds' nests can block the opening and are flammable. Recommend installing a new vent cap.
Caulk is missing or deteriorated around windows in some areas. Recommend caulking where necessary.
| Roof | Return to table of contents |
| Attached garage | Return to table of contents |
Found the garage door light not working and need of replacement or repair.
| Electric service | Return to table of contents |


Ground fault circuit interrupter (GFCI) breaker(s) in the main service panel wouldn't trip when tested. Recommend having a qualified, licensed electrician evaluate and repair or replace as necessary.
![]() Photo 5 |

One or more smoke detectors is damaged or missing. Recommend replacing inoperable smoke detectors as necessary so a functioning one exists in each hallway leading to bedrooms, and in each bedroom. For more information on smoke detectors visit http://www.cpsc.gov/cpscpub/pubs/5077.html
| Water heater | Return to table of contents |

The water heater's temperature-pressure relief valve drain line is missing. This poses a danger of scalding if someone is standing next to the water heater when the valve releases. A qualified plumber should install a drain line as per standard building practices. For example, extending to within 6" from the floor, or routed so as to drain outside.
![]() Photo 6 |
| Heating and air conditioning | Return to table of contents |

The estimated useful life for forced air furnaces is 15 to 20 years. This furnace appears to be at this age or older and may need replacing at any time.

The estimated useful life for air conditioning compressors is 8 to 15 years. This unit appears to have exceed this age and may need replacing at any time.

This system is equipped with throw-away filter(s). They appear to be dirty. Recommend replacing filter(s) now and every 2 months in the future if the thermostat's fan position is set to "Auto", or monthly if it's set to "On".
Recommend that this system be inspected, cleaned, serviced and repaired if necessary by a qualified heating and cooling technician annually in the future.
There is a 10 degree difference on the air going to the added room. Recomended hiring a Licensed A/C Contractor to upgrade or add another duct.
| Attic | Return to table of contents |
Note Nail Spacing and length is good on ceiling structure.
![]() Photo 4 |
| Plumbing and laundry | Return to table of contents |

Recommend having septic tank inspected. Recommend pumping tank if last pumped more than 3 years ago.
Noted the washer has been leaking and the carpet is wet in that area.
| Interior rooms | Return to table of contents |

No ground fault circuit interrupter (GFCI) devices (receptacles or circuit breakers) are visible in the kitchen or bathrooms. GFCI devices help prevent electric shocks in areas that may have water present. Recommend having a qualified, licensed electrician install GFCI protection for receptacles over counter tops and around sinks as per standard building practices.
Screen(s) missing in one or more windows. Window(s) may not provide ventilation during months when insects are active. Recommend installing screens.
Window(s) stuck shut and can't open. Recommend repairing window(s) so they open easily.
No exhaust fan is installed in the laundry room. This can lead to excessive accumulation of moisture. Recommend having a qualified contractor install an exhaust fan with a timer, duct and vent cap as per standard building practices in the laundry room.
The dishwasher supply line is crimped under the kitchen sink. Replace the line so it has proper water flow.
![]() Photo 2 |
The hall toilet is filling up slow. Recommended replacing the flush vaulve and supply vaulve. The handle is also rust and may break at anytime.
![]() Photo 3 |
The entire floor of the kitchen cabnet under the sink has water damage and is in need of replacement.
![]() Photo 1 |
The master bathroom facet and the hall facet have poor water flow and are rusted and may need replacing.
The hall shower stem is dripping and leaking and in need of repair or replacement.
The hall tub spout is rusted due to laking and should be replaced.
The kitchen facet makes noise when on and the sprayer leaks. Recomended replacement.
Window(s) broken. Recommend replacing glass. In Blue Bedroom
One or more sink stopper mechanisms are missing, inoperable or in disrepair. Recommend intalling or repairing sink stopper mechanisms as necessary.
Caulk needs repair around the base one or more tub faucets. Recommend applying a bead of caulk around the base of tub faucets where necessary.