Website: http://www.ocalahomeinspection.com
Email: Mjvanek1@aol.com
Phone: (352) 361-8065
FAX: (352) 288-3764
PO Box 4891
Ocala, FL
34478
Inspector: Michael Vanek
|
Professional Home Inspection |
| Client(s): |
Fitzgerald (The Villages - Bobby Gulati) |
| Property address: |
1264 Vista Lago PL The Villages, FL 32159 |
| Inspection date: |
Friday, May 18, 2007 |
This report published on 5/20/2007 11:03:47 AM EDT
View summary page
This report is the exclusive property of this inspection company and the client(s) listed in the report title. Use of this report by any unauthorized persons is prohibited.
How to Read this Report
This report is organized by the property's functional areas. Within each functional area, descriptive information is listed first and is shown in bold type. Items of concern follow descriptive information.
Concerns are shown and sorted according to these types: | Major defect | Correction likely involves a significant expense |
 | Repair/Maintain | Recommend repair and/or maintenance |
 | Maintain | Recommend ongoing maintenance |
 | Comment | For your information |
Click here for a glossary of building construction terms.
Contact your inspector if there are terms that you do not understand, or visit the glossary of construction terms at http://www.reporthost.com/glossary.asp
Table of Contents
General information
Exterior
Roof
Attached garage
Electric service
Water heater
Heating and air conditioning
Plumbing and laundry
Interior rooms
Payment & Billing: To be Paid at Closing, $250.00
Structures inspected: Home
Present during inspection: None
Occupied: No
Age of building: 7 years
Type of building: Condo
Footing material: Masonry
Foundation material: Poured in place concrete
Apparent wall structure: Wood frame
Wall covering: Stucco
Driveway material: Poured in place concrete
Sidewalk material: Poured in place concrete
Exterior door material: Solid core steel, Glass panel
1)
There is cracked stucco on the front of the porch exterior front bedroom balcony. Recomened repairing .

Photo 3
|
2)
The front bedroom upstairs on the balcony has areas above the door that are not properly sealed allowing water to enter behind the frame of the door.Recomended repairing as needed.

Photo 2
|
3)
The back downstairs patio has a small crack in it that is just cosmetic and has no concerns.
Number of Remaing Years of Life: Unable to Determin Tile roofs are standard to 30+ years
Roof type: Cross gable
Roof covering: Clay tile
Estimated age of roof: 7 years
Gutter & downspout material: Aluminum
Roof ventilation: Adequate
4)
No Concerns for the garage were found.
Primary service type: Underground
Primary service overload protection type: Circuit breakers
Service amperage (amps): 200
Service voltage (volts): 3 phase 120-240
Location of main service panel: Exterior Wall
Location of sub panels: Garage Wall
Location of main disconnect: No single main disconnect, use all breakers in main service panel
Main disconnect rating (amps): 200
Smoke detectors present: Yes
Estimated age of Water Heater: 7 years
Type: Tank
Energy source: Natural gas
Brand & model: AO Smith Model 21V40-38
Water temperature (degrees Fahrenheit): 105 degrees
5)

The estimated useful life for most water heaters is 8 to 12 years. This water heater appears to be approaching this age. Recommend budgeting for a replacement in the near future.
Heating system energy source: Natural gas
Heat system type: Forced air
A/C energy source: Electric
Air conditioning type: Split system
Distribution system: Flexible ducts
Brand & model: Carrier Model 58PAV090-16
Filter location: Behind return air grill
6)
The air condition vent in the laundry room is loose and needs tightened.
7)
Recommend that this system be inspected, cleaned, serviced and repaired if necessary by a qualified heating and cooling technician annually in the future.
Water service: Public
Supply pipe material: CPVC
Vent pipe material: Plastic
Drain pipe material: Plastic
Waste pipe material: Plastic
8)
The upstairs hall bath runs with water leaking around the flapper. Recomended changing the flapper to prevent extra water usage.
9)
The sliding locks on all of the patio stationary doors need lubricated to work properley.
10)
The front upstairs bedroom patio door is missing all screws on the middle hindge.Recomended replacing the proper screws.

Photo 4
|
11)
The kitchen sink sprayer is clogged and needs cleaned to work properly.
12)
Unable to check icemaker it was not on during the inspection.
1. INSPECTOR agrees to perform a visual inspection of the home/building and to provide CLIENT with a written inspection report identifying the defects that INSPECTOR both observed and deemed material. INSPECTOR may offer comments as a courtesy, but these comments will not comprise the bargained-for report. The report is only supplementary to the sellers disclosure.
2. Unless otherwise inconsistent with this Agreement or not possible, INSPECTOR agrees to perform the inspection in accordance to the current Standards of Practice of the National Association of Certified Home Inspectors posted at http://www.nachi.org/sop.htm. CLIENT understands that these standards contain certain limitations, exceptions, and exclusions.
3. The inspection and report are performed and prepared for the use of CLIENT, who gives INSPECTOR permission to discuss observations with real estate agents, owners, repairpersons, and other interested parties. INSPECTOR accepts no responsibility for use or misinterpretation by third parties. INSPECTORS inspection of the property and the accompanying report are in no way intended to be a guarantee or warranty, express or implied, regarding the future use, operability, habitability or suitability of the home/building or its components. Any and all warranties, express or implied, including warranties of merchantability and fitness for a particular purpose, are expressly excluded by this Agreement.
4. INSPECTOR assumes no liability for the cost of repair or replacement of unreported defects or deficiencies either current or arising in the future. CLIENT acknowledges that the liability of INSPECTOR, its agents, employees, for claims or damages, costs of defense or suit, attorneys fees and expenses and payments arising out of or related to the INSPECTORS negligence or breach of any obligation under this Agreement, including errors and omissions in the inspection or the report, shall be limited to liquidated damages in an amount equal to the fee paid to the INSPECTOR, and this liability shall be exclusive. CLIENT waives any claim for consequential, exemplary, special or incidental damages or for the loss of the use of the home/building even if the CLIENT has been advised of the possibility of such damages. The parties acknowledge that the liquidated damages are not intended as a penalty but are intended (i) to reflect the fact that actual damages may be difficult and impractical to ascertain; (ii) to allocate risk among the INSPECTOR and CLIENT; and (iii) to enable the INSPECTOR to perform the inspection at the stated fee.
5. INSPECTOR does not perform engineering, architectural, plumbing, or any other job function requiring an occupational license in the jurisdiction where the inspection is taking place, unless the inspector holds a valid occupational license, in which case he/she may inform the CLIENT that he/she is so licensed, and is therefore qualified to go beyond this basic home inspection, and for additional fee, perform additional inspections beyond those within the scope of the basic home inspection. Any agreement for such additional inspections shall be in a separate writing.
6. In the event of a claim against INSPECTOR, CLIENT agrees to supply INSPECTOR with the following: (1) Written notification of adverse conditions within 14 days of discovery, and (2) Access to the premises. Failure to comply with the above conditions will release INSPECTOR and its agents from any and all obligations or liability of any kind.
7. The parties agree that any litigation arising out of this Agreement shall be filed only in the Court having jurisdiction in the County in which the INSPECTOR has its principal place of business. In the event that CLIENT fails to prove any adverse claims against INSPECTOR in a court of law, CLIENT agrees to pay all legal costs, expenses and fees of INSPECTOR in defending said claims.
8. If any court declares any provision of this Agreement invalid or unenforceable, the remaining provisions will remain in effect. This Agreement represents the entire agreement between the parties. All prior communications are merged into this Agreement, and there are no terms or conditions other than those set forth herein. No statement or promise of INSPECTOR or its agents shall be binding unless reduced to writing and signed by INSPECTOR. No change or modification shall be enforceable against any party unless such change or modification is in writing and signed by the parties. This Agreement shall be binding upon and enforceable by the parties and their heirs, executors, administrators, successors and assignees. CLIENT shall have no cause of action against INSPECTOR after one year from the date of the inspection.
9. Payment of the fee to INSPECTOR (less any deposit noted above) is due upon completion of the on-site inspection. The CLIENT agrees to pay all legal and time expenses incurred in collecting due payments, including attorneys fees, if any. If CLIENT is a corporation, LLC, or similar entity, the person signing this Agreement on behalf of such entity does personally guaranty payment of the fee by the entity.
CLIENT HAS CAREFULLY READ THE FOREGOING, AGREES TO IT, AND ACKNOWLEDGES RECEIPT OF A COPY OF THIS AGREEMENT.