MLD Home Inspections

Website: http://www.reporthost.com/mldhome
Email: MLDinspections@optonline.net
Phone: (516) 864-9123 · (516) 857-3087
FAX: (516) 571-1404
P.O. BOX 773 
Uniondale, NY 11553
Inspector: Luis Vasquez

 

Home Inspection
Client(s): George Valentin
Property address: 38 W 11th St
Huntington Sta. NY
Inspection date: Friday, November 10, 2006
This report published on 11/15/2006 2:04:07 PM CST

View summary page

This report is the exclusive property of MLD Home Inspections and the client(s) listed in the report title. Use of this report by any unauthorized persons is prohibited.


How to Read this Report
This report is organized by the property's functional areas. Within each functional area, descriptive information is listed first and shown in bold type. Items of concern follow descriptive information and are shown as follows:
SafetyPoses a risk of injury or death 
Repair/ReplaceRecommend repairing or replacing 
Repair/MaintainRecommend repair and/or maintenance 
Minor defectCorrection likely involves only a minor expense 
MaintainRecommend ongoing maintenance 
EvaluateRecommend evaluation by a specialist 
ServiceableItem or component is in servicable condition 
CommentFor your information 
Concern items are sorted by the types listed above.  Click here for a glossary of building construction terms.  Contact your inspector if there are terms that you do not understand, or visit the glossary of construction terms at http://www.reporthost.com/glossary.asp

Structural Pest Inspection Concerns
Items marked with the following icons relate to the structural pest inspection
InfestationEvidence of infestation of wood destroying insects or organisms (Live or dead insect bodies, fungal growth, etc.)
DamageDamage caused by wood destroying insects or organisms (Rot, carpenter ant galleries, etc.)
Conducive
conditions
Conducive conditions for wood destroying insects or organisms. (Wood-soil contact, shrubs in contact with siding, roof or plumbing leaks, etc.)

Table of Contents
General information
Exterior
Roof
Garage
Electric service
Water heater
Plumbing and laundry
Basement
Kitchen
Bathrooms
Interior rooms


General information Return to table of contents  
Report number: Valentin38
Structures inspected: Residence
Type of building: Single family
Property owner's name:
Time started: 1:00pm
Time finished: 2:45pm
Inspection Fee: $300
Payment method: Check
Present during inspection: Tenant(s)
Occupied: Yes
Weather conditions: Clear
Temperature: Cool
Ground condition: Damp
Front of structure faces: South
Main entrance faces: South
Foundation type: Finished basement
The following items are excluded from this inspection: Private sewage disposal system, Security system, Irrigation system, Swimming pool, Hot tub, Private well, Shed, Playground equipment, Sauna, Low voltage outdoor lighting, Central vacuum system, Water filtration system, Water softener system, Built-in sound system, Intercom system, Generator system, Sport court, Sea wall, OutbuildingsDetach Garages
  1) This property has one or more fuel burning appliances, and no carbon monoxide alarms are visible. This is a safety hazard. Recommend installing one or more carbon monoxide alarms as necessary and as per the manufacturer's instructions. For more information, visit http://www.cpsc.gov/CPSCPUB/PREREL/prhtml05/05017.html
  2) Many wall, floor and/or ceiling surfaces were obscured by large amounts of furniture and/or stored items. Many areas couldn't be evaluated.
 
Exterior Return to table of contents  
Footing material: Poured in place concrete
Foundation material: Poured in place concrete
Apparent wall structure: Wood frame
Wall covering: Vinyl
Driveway material: GravelDriveway is not leveled at this time.
Sidewalk material: Poured in place concrete
Exterior door material: Solid core steel-Insulated steel door
  3) One or more light fixtures are loose or installed in a substandard way. A qualified contractor or electrician should evaluate and make repairs as necessary so light fixtures are securely mounted and installed in accordance with the manufacturer's installation instructions.

Photo 96  
 
  4) Guardrails are loose and/or wobbly in one or more areas. This is a safety hazard. A qualified contractor should evaluate and make repairs as necessary, such as installing new fasteners or hardware, installing additional fasteners and/or installing additional railing components as necessary so they are securely attached.

Photo 48  
 
  5) Handrail(s) at some stairs are loose. This is a safety hazard. A qualified contractor should make repairs as necessary. For example, installing new fasteners and/or hardware so handrails are securely attached.

Photo 5  
 
  6) Gaps larger than four inches were found in one or more guardrails. This is a safety hazard, especially for small children. A qualified contractor should make modifications as necessary so gaps in guardrails do not exceed four inches. For example, installing additional balusters or railing components.

Photo 32  

Photo 33  
7) One or more downspouts have no extensions, or have extensions that are ineffective. This can result in water accumulating around the structure's foundation, or in basements and crawl spaces if they exist. Accumulated water is a conducive condition to wood destroying insects and organisms, and may also cause the foundation to settle and possibly fail over time. Repairs should be made as necessary, such as installing or repositioning splash blocks, or installing and/or repairing tie-ins to underground drain lines, so rain water is carried at least several feet away from the structure to soil that slopes down and away from the structure.

Photo 6  

Photo 10  
8) The perimeter grading slopes towards the structure in one or more areas. This can result in water accumulating around the structure's foundation, or in basements and crawl spaces if they exist. Accumulated water is a conducive condition to wood destroying insects and organisms. Wet soil may also cause the foundation to settle and possibly fail over time. Recommend grading soil so it slopes down and away from the structure with a slope of at least 5% (10% or better is optimal) for at least 6 feet.

Photo 9  

Photo 16  

Photo 25  
 
  9) Soffit boards are damaged, exposed and/or deteriorated in one or more areas. A qualified contractor should evaluate and make repairs as necessary.

Photo 11  

Photo 41  
  10) Fascia boards are exposed and loose in one or more areas. A qualified contractor should evaluate and make repairs as necessary.

Photo 39  

Photo 41  
11) One or more wooden deck support posts are in contact with soil. This is a conducive condition for wood destroying insects and organisms. However no damage from wood destroying insects or organisms was found. Standard building practices require that there be at least 6" of space between any wood and the soil below, even if the wood is treated. If possible, soil should be removed or graded so a 6" clearance is maintained. Otherwise recommend installing borate based Impel rods to prevent rot.

Photo 13  

Photo 14  
  12) The gravel driveway is in poor condition. Repairs should be made as necessary, such as filling holes or grading, and new gravel should be spread.

Photo 3  

Photo 46  
13) Recommend cleaning deck(s) and treating with a preservative claiming to waterproof, block ultraviolet light, and stop mildew. Consumer Reports recommends these products:

  • Cabot Decking Stain and PTW Stain
  • Olympic Water Repellent Deck Stain
  • Thompson's House and Deck Stain
  • Wolman PTW Deck Stain
  • Akzo Sikkens Cetol DEK
  • Benjamin Moore Moorwood Clear Wood Finish
  • DAP Woodlife Premium
  • Olympic Natural Look Protector Plus

    Photo 49  
     
  •   14) One or more moderate cracks (1/8 inch to 3/4 inch) were found in the basement entrance foundation. These may be a structural concern, or an indication that settlement is ongoing. The client(s) should consider hiring qualified contractors and/or engineers as necessary for further evaluation. Such contractors may include:

  • Foundation repair contractors who may prescribe repairs, and will give cost estimates for prescribed repairs
  • Masonry contractors who repair and/or replace brick veneer
  • Geotechnical engineers who attempt to determine if settlement is ongoing, and what the cause of the settlement is
  • Structural engineers who determine if repairs are necessary, and prescribe those repairs

    At a minimum, recommend sealing cracks to prevent water infiltration. Numerous products exist to seal such cracks including:
  • Hydraulic cement. Requires chiseling a channel in the crack to apply. See http://www.quickrete.com/catalog/HydraulicWater-StopCement.html for an example.
  • Resilient caulks (easy to apply). See http://www.quickrete.com/catalog/GrayConcreteRepair.html for an example.
  • Epoxy sealants (both a waterproof and structural repair). See http://www.mountaingrout.com/ for examples of these products.

    Photo 100  

    Photo 101  

    Photo 102  

    Photo 103  
  • 15) One or more minor cracks (1/8 inch or less) were found in the foundation. These don't appear to be a structural concern, but recommend sealing them to prevent water infiltration and monitoring them in the future. Numerous products exist to seal such cracks including:
  • Hydraulic cement. Requires chiseling a channel in the crack to apply. See http://www.quickrete.com/catalog/HydraulicWater-StopCement.html for an example.
  • Resilient caulks (easy to apply). See http://www.quickrete.com/catalog/GrayConcreteRepair.html for an example.
  • Epoxy sealants (both a waterproof and structural repair). See http://www.mountaingrout.com/ for examples of these products.

    Photo 18  

    Photo 106  
  • 16) Trees and/or shrubs are in contact with or are close to the roof edge(s) in one or more areas. Damage to the roof may result, especially during high winds. Vegetation can also act as a conduit for wood destroying insects. Vegetation should be pruned back and/or removed as necessary to prevent damage and infestation by wood destroying insects.

    Photo 31  

    Photo 37  
      17) One or more light fixtures have missing bulbs and could not be fully evaluated. Bulbs may simply need to be installed, or repairs or replacement may be necessary.
     
    Roof Return to table of contents  
    Roof inspection method: Viewed from ground with binoculars
    Roof type: Gable
    Roof covering: Asphalt or fiberglass composition shingles
    Estimated age of roof: 6 years
    Gutter & downspout material: Aluminum
    Roof ventilation: AdequateRidge Vent
    18) Trees are overhanging roof and are within 10 feet of roof vertically. This is a conducive condition for wood destroying insects and organisms since organic debris such as leaves or needles are more likely to accumulate on the roof surface. Accumulated debris may cause water to enter gaps in the roof surface and leak into attic and/or interior spaces. Trees should be pruned so they are at least 10 feet above roof, or don't overhang the roof.

    Photo 30  
     
    19) Debris such as leaves, needles, seeds, etc. have accumulated on the roof. This is a conducive condition for wood destroying insects and organisms since water may not flow easily off the roof, and may enter gaps in the roof surface. Leaks may occur as a result. Debris should be cleaned from the roof now and as necessary in the future.

    Photo 29  
     
     
    Garage Return to table of contents  
      20) Most areas inside the garage, including the perimeter, areas in the center, and one or more vehicle doors were obscured by stored items and/or debris and couldn't be fully evaluated.
     
    Electric service Return to table of contents  
    Primary service type: Overhead
    Primary service overload protection type: Circuit breakers
    Service amperage (amps): 100
    Service voltage (volts): 120/240
    Location of sub panels: Second Floor
    Location of main disconnect: Breaker at top of main service panel
    Service entrance conductor material: Copper
    System ground:
    Main disconnect rating (amps): 100
    Smoke detectors present: No
      21) The main service panel cover couldn't be removed due to lack of access from stored items and/or debris. This panel wasn't fully evaluated.

    Photo 60  

    Photo 61  
     
    Water heater Return to table of contents  
        22) Unable to check water heater due to lack of access to the basement. Homeowner was not present to gain access to basement.
     
    Plumbing and laundry Return to table of contents  
        23) Unable to check plumbing due to lack of access to basement.
     
    Basement Return to table of contents  
        24) Unable to check this section of residence due to lack of access.
     
    Kitchen Return to table of contents  
      25) One or more stove top burners are inoperable. A qualified appliance technician should evaluate and repair as necessary.

    Photo 105  
     
      26) One or more faucet handles are loose or missing and should be repaired or replaced as necessary.

    Photo 69  
     
    27) Caulk is missing and/or deteriorated where countertops meet backsplashes in wet areas, such as around sinks. Caulk should be replaced where deteriorated and/or applied where missing to prevent water damage.

    Photo 64  

    Photo 72  
     
    Bathrooms Return to table of contents  
    28) Tile and/or grout in one or more showers is damaged and/or deteriorated. For example, deteriorated or missing grout, cracked, missing or loose tiles, etc. A qualified contractor should evaluate and repair tile and/or grout as necessary.

    Photo 83  
     
      29) Second floor toilet appear to be clogged, and/or do not flush adequately. A qualified plumber should evaluate and make repairs or replace toilet(s) as necessary.

    Photo 79  
     
      30) The enamel coating on one or more bathtubs is damaged and/or deteriorated. For example, chipped or worn, and/or rust on some exposed steel. However, no leaks were found due to the deterioration. The client(s) should evaluate to determine if the bathtub(s) should be refinished or replaced.

    Photo 50  
     
     
    Interior rooms Return to table of contents  
      31) Extension cords are being used as permanent wiring in one or more areas. They should only be used for portable equipment on a temporary basis. Using extension cords as permanent wiring poses a fire and shock hazard, and is an indication that wiring is inadequate and should be updated. Extension cords may be undersized. Connections may not be secure, resulting in power fluctuations, damage to equipment, and sparks that could start a fire. Extension cords should be removed as necessary, or a qualified electrician should evaluate and make repairs as necessary. For example, install additional circuits and/or electric receptacles.
      32) One or more smoke alarms are damaged, deteriorated and/or missing from their mounting brackets. Damaged and/or missing smoke alarms should be replaced as necessary so a functioning one exists in each hallway leading to bedrooms, and in each bedroom. For more information, visit http://www.cpsc.gov/cpscpub/pubs/5077.html

    Photo 53  

    Photo 63  
      33) Cover plate(s) are broken at one or more electric boxes, such as for receptacles, switches and/or junction boxes. They are intended to contain fire and prevent electric shock from exposed wires. This is a safety hazard due to the risk of fire and shock. Cover plates should be replaced where necessary.

    Photo 52  

    Photo 80  
    34) Tile, stone and/or grout flooring is damaged and/or deteriorated in one or more areas. A qualified contractor should evaluate and make repairs as necessary. For example, replacing broken tiles and deteriorated grout, and resealing grout.

    Photo 78  
     
      35) One or more electric baseboard heaters are damaged or deteriorated. For example, missing, bent or loose metal panels. A qualified electrician should evaluate and repair or replace heaters as necessary.

    Photo 58  

    Photo 85  
      36) One or more doors bind in their jamb and cannot be closed and latched, or are difficult to open and close. A qualified contractor should evaluate and repair as necessary. For example, adjusting jambs or trimming doors.

    Photo 91  

    Photo 92  
     

    Photo 2  
    Roof appears serviseable.

    Photo 4  
    Sidewalk appears serviceable

    Photo 7  

    Photo 8  

    Photo 12  

    Photo 15  

    Photo 17  
    Signs of deterioration due to accumulating water.

    Photo 19  

    Photo 20  

    Photo 21  
    West side foundation appears serviceable.

    Photo 22  
    Electric box meter, joints and entry points appear serviceable.

    Photo 23  

    Photo 24  

    Photo 26  
    Concrete broken at base of front handrail.

    Photo 27  

    Photo 28  
    Anchor bolt should be tighten to secure front handrail.

    Photo 34  

    Photo 35  

    Photo 36  
    This section of garage roof appears to be caving in. this may be due to roof rafters failing.

    Photo 38  
    Rear section of garage bowing. Further evaluation is needed.

    Photo 40  

    Photo 42  

    Photo 43  

    Photo 44  

    Photo 45  

    Photo 47  
    Siding damaged/melted.

    Photo 51  

    Photo 54  

    Photo 55  

    Photo 56  

    Photo 57  

    Photo 59  

    Photo 62  

    Photo 65  

    Photo 66  

    Photo 67  

    Photo 68  

    Photo 70  

    Photo 71  

    Photo 73  

    Photo 74  

    Photo 75  

    Photo 76  

    Photo 77  

    Photo 81  
    Light not working at this time. May need light bulb.

    Photo 82  
    First floor bathroom shout off valve pipe loose.

    Photo 84  

    Photo 86  

    Photo 87  

    Photo 88  
    2nd floor closet light inop.

    Photo 89  

    Photo 90  

    Photo 93  

    Photo 94  

    Photo 95  

    Photo 97  

    Photo 98  
    Branch by fence may be a tripping hazard.

    Photo 99  

    Photo 104  
    Basement entrance window broken.