View as PDF

Meeker Industries, Inc.

Website: http://www.homeinspection.meekerindustries.com
Email: mike@meekerindustries.com
Phone: (954) 922-0584
Dania Beach FL 33004-2332
Inspector: Michael Meeker

 

Property Inspection Report
Client(s): Bob Barker
Property address: 4780 NE 17th Avenue
Pompano Beach, Florida 33064
Inspection date: Tuesday, January 12, 2010
This report published on Monday, February 07, 2011 11:15:02 PM EST

View summary page

This report is the exclusive property of this inspection company and the client(s) listed in the report title. Use of this report by any unauthorized persons is prohibited.

 
How to Read this Report
This report is organized by the property's functional areas.  Within each functional area, descriptive information is listed first and is shown in bold type.  Items of concern follow descriptive information.
Concerns are shown and sorted according to these types:
SafetyPoses a risk of injury or death 
Major DefectCorrection likely involves a significant expense 
Repair/ReplaceRecommend repairing or replacing 
Repair/MaintainRecommend repair and/or maintenance 
Minor DefectCorrection likely involves only a minor expense 
MaintainRecommend ongoing maintenance 
EvaluateRecommend evaluation by a specialist 
CommentFor your information 

Click here for a glossary of building construction terms.  Contact your inspector if there are terms that you do not understand, or visit the glossary of construction terms at http://www.reporthost.com/glossary.asp

Table of Contents
General information
Exterior
Roof
Attic
Electric service
Water heater
Heating and cooling
Plumbing and laundry
Kitchen
Bathrooms
Interior rooms
 
General information Return to table of contents
Inspector's name: Michael Meeker
Type of building: Single family
Age of building: Approximately 53 Years Old
Time started: 10:30am
Time finished: 12:30pm
Inspection Fee: 200.00
Payment method: Check
Present during inspection: None
Occupied: No
Weather conditions: Clear
Temperature: Cold
Ground condition: Dry
Foundation type: Slab on grade
1) The wall unit air conditioner should not be pluged in or turned on. A licensed air conditioning contractor should inspect it.
2) The central air conditioner should not be turned on. A licensed air conditioning contractor should inspect it to determine why there is no power to the unit and the current condition of the unit should be evaluated.
3) Structures built prior to 1979 may contain lead-based paint and/or asbestos in various building materials such as insulation, siding, and/or floor and ceiling tiles. Both lead and asbestos are known health hazards. Evaluating for the presence of lead and/or asbestos is not included in this inspection. The client(s) should consult with specialists as necessary, such as industrial hygienists, professional labs and/or abatement contractors for this type of evaluation. For information on lead, asbestos and other hazardous materials in homes, visit these websites:
  • The Environmental Protection Association (http://www.epa.gov)
  • The Consumer Products Safety Commission (http://www.cpsc.gov)
  • The Center for Disease Control (http://www.cdc.gov)
    4) The water service wasn't turned on during the inspection. As a result, plumbing supply, drain and waste lines, fixtures, and some appliances such as water heaters weren't fully evaluated.
     
    Exterior Return to table of contents
    Apparent wall structure: Wood frame, Concrete block
    Wall covering: Stucco
    Driveway material: Poured in place concrete
    Sidewalk material: Poured in place concrete
    Exterior door material: The unit has both wood and metal doors
    5) One or more trip hazards were found in the driveway due to cracks, settlement and/or heaving. Recommend having a qualified contractor evaluate and repair or replace driveway sections as necessary to eliminate trip hazards.

    Photo 1  
     

    6) One or more trip hazards were found in sidewalk and/or patio sections due to cracks, settlement and/or heaving. A qualified contractor should evaluate and repair or replace sidewalk and/or patio sections as necessary to eliminate trip hazards.
    7) One or more large trees on the property may be likely to fall on the structure, and are a potential safety hazard. Recommend consulting with a qualified arborist to determine if tree(s) need to be removed and/or pruned.
    8) One or more light fixtures are loose or installed in a substandard way. A qualified contractor or electrician should evaluate and make repairs as necessary so light fixtures are securely mounted and installed in accordance with the manufacturer's installation instructions.

    Photo 37  
     

    9) Cracks, deterioration and/or damage were found in one or more areas of the stucco siding. A qualified contractor should evaluate and make repairs and/or replace stucco siding as necessary.

    Photo 3  
     

    10) Rot was found in one or more areas. A qualified contractor should evaluate and repair as necessary. All rotten wood should be removed or replaced.

    Photo 5  
     

    11) Rot was found in one or more areas on soffit boards. A qualified contractor should evaluate and make repairs as necessary, replacing all rotten wood.
    12) Fascia boards are damaged or deteriorated in one or more areas. A qualified contractor should evaluate and make repairs as necessary.

    Photo 5  
     

    13) One or more outside faucets appeared to be inoperable. No water came out of the faucet(s) when turned on. This may be due to a (winterizing) shut-off valve being turned off. As per the NACHI and ASHI Standards of Practice, the inspector did not attempt to turn on or off any water supply shut-off valves. Recommend that the client(s) ask the seller about outside faucets with no water, and/or have a qualified plumber evaluate and repair faucet(s) as necessary.
    14) One or more large trees are very close the foundation. Tree roots can cause significant structural damage to foundations. Recommend having a qualified tree service contractor or arborist remove trees as necessary to prevent damage to the structure's foundation.
    15) One or more gutters are missing. This can result in water accumulating around the structure's foundation, or in basements and crawl spaces if they exist. Accumulated water is a conducive condition to wood destroying insects and organisms, and may also cause the foundation to settle and possibly fail over time. A qualified contractor should install gutters and downspouts where missing. Also, extensions such as splashblocks or tie-ins to underground drain lines should be installed as necessary to carry rain water away from the house.
    16) Gaps exist at one or more openings around the exterior, such as those where outside faucets, refrigerant lines, and/or gas supply pipes penetrate the exterior. Gaps should be sealed as necessary to prevent moisture intrusion and entry by vermin.

    Photo 6  
     

    17) One or more soffit vent screens are missing and/or deteriorated. Birds and vermin may enter the attic because of this. Screens should be replaced or repaired where necessary, or installed where missing.
    18) Soffit cover material is missing in some areas. This may result in vermin intrusion and/or damage to insulation. A qualified contractor should install vented soffit material such as plywood as per standard building practices.
    19) Vegetation such as trees, shrubs and/or vines are in contact with or less than one foot from the structure's exterior. Vegetation can serve as a conduit for wood destroying insects and may retain moisture against the exterior after it rains. Vegetation should be pruned and/or removed as necessary to maintain a one foot clearance between it and the structure's exterior.
    20) Trees and/or shrubs are in contact with or are close to the roof edge(s) in one or more areas. Damage to the roof may result, especially during high winds. Vegetation can also act as a conduit for wood destroying insects. Vegetation should be pruned back and/or removed as necessary to prevent damage and infestation by wood destroying insects.
    21) The exterior finish in some areas is failing. A qualified contractor should prep (pressure wash, scrape, sand, prime caulk, etc.) and repaint or restain areas as needed and as per standard building practices.

    Photo 7  
     
     
    Roof Return to table of contents
    Roof inspection method: Viewed from eaves on ladder
    Roof type: Gable
    Roof covering: Gravel
    Estimated age of roof: 15+ years old
    Roof ventilation: Unable to determine (no access to attic spaces)
    Roof inspection method: Viewed from eaves on ladder
    Roof type: Gable
    Roof covering: Gravel
    Estimated age of roof: 15+ years old
    Roof ventilation: Unable to determine (no access to attic spaces)
    22) One or more plumbing vent pipes terminate less than six inches above the roof surface below. Debris may block openings, and may result in sewer gases entering living spaces. A qualified contractor should evaluate and make repairs as necessary so vent pipes terminate at least six inches above roof surfaces.
    23) The roof surface material appears to be near the end of its service life and will likely need replacing in the near future, even with repairs. The client(s) should budget for a replacement roof surface, and may want to have a qualified roofing contractor evaluate and attempt to issue a "5 year roof certificate".

    Photo 19  
     
     
    Attic Return to table of contents
    Inspection method: Not inspected
    Roof structure type: Rafters
    Ceiling structure: Not visible
    Insulation material: None visible
    24) No access hatch was found for the attic. The inspector was unable to evaluate the attic, and it's excluded from this inspection. Recommend having a qualified contractor install access hatches as necessary and as per standard building practices to allow periodic evaluation of attic spaces.
    25) Screens are missing and/or deteriorated at one or more soffit, gable, and/or ridge vents. Birds and vermin may enter the attic because of this. Screens should be replaced or repaired where necessary, or installed where missing.
    26) No accessible attic spaces were found or inspected at this property. The property should be inspected for termites.
     
    Electric service Return to table of contents
    Primary service type: Overhead
    Primary service overload protection type: Circuit breakers
    Service amperage (amps): 200
    Location of main service switch: outside on wall in panel
    Location of main disconnect: Breaker at top of main service panel
    System ground: Cold water supply pipes
    Smoke detectors present: No
    27) The entire electrical system needs to be evaluated by a licensed electrician as numerous dangerous conditions may be present.
    28) One or more pointed and/or too-long screws are used to fasten the cover to the main service panel. These types of screws are more likely to come into contact with wiring inside the panel than stock screws from the manufacturer, and can damage wiring insulation. This is a safety hazard due to the risk of shock and/or fire. Long and/or pointed crews should be replaced as necessary with the correct screws, and if necessary by a qualified electrician.

    Photo 31  
     
     
    Water heater Return to table of contents
    Estimated age: 10+ years old
    Type: Tank
    Energy source: Electricity
    Manufacturer: Richmond
    Model: 8sv40-2c
    29) Substandard wiring was found for the water heater's power supply. Exposed non-metallic sheathed (Romex) wiring is used and is subject to damage. Both the insulation and conductors can be damaged by repeated movement or contact with objects such as stored items. This is a safety hazard for both fire and shock. A qualified electrician should evaluate and repair as necessary. Typically, flexible conduit with bushings is used in this application.
    30) The estimated useful life for most water heaters is 8 to 12 years. This water heater appears to be at this age or older and may need replacing at any time. Recommend budgeting for a replacement in the near future.
    31) The water heater was turned off at the time of the inspection. For example, circuit breaker turned off, gas supply turned off or pilot light turned off. The inspector was unable to fully evaluate the water heater.
     
    Heating and cooling Return to table of contents
    Estimated age: 10+
    Primary heating system energy source: Electric
    Primary heat system type: Heat from the a/c unit
    Primary A/C energy source: Electric
    Primary Air conditioning type: Split system
    Distribution system: Not visible
    Manufacturer: Rheem
    Model: info cannot be read
    32) Do not plug in or turn on wall unit. Have evaluated by licensed air conditioning contractor.
    33) The air conditioning system did not respond when its controls were operated. This system was not fully evaluated. The client(s) should consult with the property owner(s) as to how it operates and have a qualified heating and cooling contractor evaluate and make repairs if necessary.
    34) The estimated useful life for most air conditioning compressors is 8 to 15 years. The inspector was unable to determine the age of the air conditioning compressor. The clients should be aware that this air conditioning compressor may be near, at, or beyond its useful life and may need replacing at any time. Recommend attempting to determine the air conditioning compressor's age (ask property owner or service technician), and budgeting for a replacement if necessary.
    35) The air conditioning system's condensing unit was shut off at the time of the inspection. For example, the electric supply was turned off. As a result, the inspector was unable to fully evaluate this unit.
     
    Plumbing and laundry Return to table of contents
    Location of main water shut-off valve: outside
    Location of main water meter: By sidewalk out front
    Water service: Public
    Waste pipe material: Not visible
    36) Copper water supply pipes in homes built prior to 1986 may be joined with solder that contains lead. Lead is a known health hazard, especially for children. Laws were passed in 1985 prohibiting the use of lead in solder, but prior to that solder normally contained about 50 percent lead. The client(s) should be aware of this, especially if children will be living in this structure. Evaluating for the presence of lead in this structure is not included in this inspection. The client(s) should consider having a qualified lab test for lead, and if necessary take steps to reduce or remove lead from the water supply. Various solutions such as these may be advised:

  • Flush water taps or faucets. Do not drink water that has been sitting in the plumbing lines for more than six hours.
  • Install appropriate filters at points of use.
  • Use only cold water for cooking and drinking. Hot water dissolves lead more quickly than cold water.
  • Use bottled or distilled water.
  • Treat well water to make it less corrosive.
  • Have a qualified plumbing contractor replace supply pipes and/or plumbing components as necessary.

    For more information visit:
    http://www.cpsc.gov/CPSCPUB/PUBS/5056.html
    http://www.epa.gov/safewater/lead/index.html
    37) There are no laundry washing machines or dryers on the premises.
     
    Kitchen Return to table of contents

    38) One or more electric receptacles have reverse-polarity wiring, where the hot and neutral wires are reversed. This is a safety hazard due to the risk of shock. A qualified electrician should evaluate and make repairs as necessary. This occures by the sink.
    39) One or more electric receptacles that serve counter top surfaces within six feet of a sink appear to have no ground fault circuit interrupter (GFCI) protection. This is a safety hazard due to the risk of shock. A qualified electrician should evaluate to determine if GFCI protection exists, and if not, repairs should be made so that all receptacles that serve countertop surfaces within six feet of sinks have GFCI protection. For example, install GFCI receptacles or circuit breaker(s) as needed.
    40) There a wires running through the cabinets.
    41) The range can tip forward, and no anti-tip bracket appears to be installed. This is a safety hazard since the range may tip forward when weight is applied to the open door, such as when a small child climbs on it, or if heavy objects are dropped on it. Anti-tip brackets have been sold with all free standing ranges since 1985. An anti-tip bracket should be installed to eliminate this safety hazard. For more information, visit:
    http://www.google.com/search?q=range+anti+tip+device

    42) One or more cabinets and/or drawers are damaged and/or deteriorated. A qualified contractor should evaluate and repair or replace cabinets and/or components as necessary.
    43) Counter tops are damaged and/or deteriorated in one or more areas. A qualified contractor should evaluate and repair or replace countertops as necessary.
    44) No range hood is installed over the range or cook top. Ventilation and/or lighting may be inadequate and moisture may accumulate indoors. Recommend having a qualified contractor install a vented and lighted range hood, with the exhaust fan configured so as to vent outdoors.
    45) Caulk is missing and/or deteriorated where counter tops meet back splashes in wet areas, such as around sinks. Caulk should be replaced where deteriorated and/or applied where missing to prevent water damage.
    46) One or more kitchen appliances appear to be near, at, or beyond their intended service life of 10 to 15 years. Recommend budgeting for replacements as necessary.
     
    Bathrooms Return to table of contents

    47) One or more ground fault circuit interrupter (GFCI) electric receptacles did not trip when tested with the inspector's test instrument. These devices should trip when tested with a test instrument in addition to tripping via the test buttons on the receptacles. This is a safety hazard due to the risk of shock. A qualified electrician should evaluate and repair as necessary.
    48) One or more ground fault circuit interrupter (GFCI) electric receptacles are damaged by paint. The "Test" and/or "Reset" button(s) don't operate properly as a result. This is a safety hazard due to the risk of shock. A qualified electrician should replace paint damaged GFCI receptacles as necessary.
    49) One or more sinks is loose, or not securely attached to the wall behind it. A qualified contractor should evaluate and repair as necessary.

    Photo 25  
     

    50) Tile and/or grout around one or more bathtubs is damaged or deteriorated. For example, deteriorated or missing grout, cracked, missing or loose tiles, etc. A qualified contractor should evaluate and repair tile and/or grout as necessary.
    51) One or more bathrooms with a shower do not have an exhaust fan installed. Moisture accumulation will occur and may damage the structure. Even if the bathroom has a window that opens, it likely does not provide adequate ventilation, especially during cold weather when the window is closed. A qualified contractor should install exhaust fans as per standard building practices where missing in bathrooms with showers.
    52) One or more toilets have no water supply and could not be fully evaluated. The shut-off valve(s) may be turned off, or repairs may be necessary. The client(s) should ask the property owner(s) about this, and have a qualified plumber evaluate and repair if necessary.
     
    Interior rooms Return to table of contents

    53) One or more open ground, three-pronged electric receptacles were found. This is a safety hazard due to the risk of shock. A qualified electrician should evaluate and make repairs as necessary. For example, replacing receptacles or correcting wiring circuits.

    Grounding type receptacles began being required in residential structures during the 1960s. Based on the age of this structure and the presence of 2-pronged receptacles in some areas of this structure, an acceptable repair may be to simply replace the ungrounded 3-pronged receptacles with 2-pronged receptacles. However the following appliances require grounding type receptacles:

  • Computer hardware
  • Refrigerators
  • Freezers
  • Air conditioners
  • Clothes washers
  • Clothes dryers
  • Dishwashers
  • Kitchen food waste disposers
  • Information technology equipment
  • Sump pumps
  • Electrical aquarium equipment
  • Hand-held motor-operated tools
  • Stationary and fixed motor-operated tools
  • Light industrial motor-operated tools
  • Hedge clippers
  • Lawn mowers

    This list is not exhaustive. Grounded circuits and receptacles should be installed in locations where such appliances will be used.
    54) Evidence of "light to moderate" rodent infestation was found in one or more areas. The Center for Disease Control (CDC) defines this as less than 20 feces per square foot. Rodent infestation may be a safety hazard due to the risk of contracting Hantavirus Pulmonary Syndrome (HPS). HPS is a rare (only 20-50 cases per year in the United states) but deadly (40% mortality rate) disease transmitted by infected rodents through urine, droppings, or saliva. Humans can contract the disease when they breathe in aerosolized virus. For example, from sweeping up rodent droppings.

    Recommend following guidelines in the CDC's Clean Up, Trap Up, Seal Up article for eradicating rodents, cleaning up their waste and nesting materials, and preventing future infestations. While Hantavirus is believed to survive less than one week in droppings and urine, specific precautions should be taken during clean up. The client(s) may wish to consult with a qualified, licensed pest control operator for eliminating the infestation. A qualified licensed abatement contractor or industrial hygienist could be contacted for clean up. If the infestation was minimal, clean up of rodent waste and nesting materials in non-living spaces (crawl spaces and attics) may not be necessary, or may be performed for aesthetic reasons only (odor and appearance).

    55) Extension cords are being used as permanent wiring in one or more areas. They should only be used for portable equipment on a temporary basis. Using extension cords as permanent wiring poses a fire and shock hazard, and is an indication that wiring is inadequate and should be updated. Extension cords may be undersized. Connections may not be secure, resulting in power fluctuations, damage to equipment, and sparks that could start a fire. Extension cords should be removed as necessary, or a qualified electrician should evaluate and make repairs as necessary. For example, install additional circuits and/or electric receptacles. This was noted in the kitchen cabinets.
    56) One or more interior doors have a keyed lockset or deadbolt installed. This is a safety hazard for small children in the event that they lock themselves in the room, do not know how to unlock the door, and the key is not available. Keyed locksets and/or deadbolts should be replaced as necessary with "privacy" locksets that don't require a key.
    57) No smoke alarms are visible. This is a safety hazard. A qualified electrician should install smoke alarms as per standard building practices (functioning one exists in hallways leading to bedrooms, and in each bedroom, etc.). For more information, visit:
    http://www.cpsc.gov/cpscpub/pubs/5077.html

    58) Cover plate(s) are missing from one or more electric boxes, such as for receptacles, switches and/or junction boxes. They are intended to contain fire and prevent electric shock from exposed wires. This is a safety hazard due to the risk of fire and shock. Cover plates should be installed where missing.

    Photo 24  
     

    59) Screen(s) in one or more windows are missing. The client(s) should ask the property owner(s) about this. Screens are often removed for window cleaning and they may be stored somewhere. If not, then recommend installing screens where missing.
    60) One or more windows that were built to open, will not open, or open only minimally due to their being painted shut, damaged and/or deteriorated in some way. Repairs should be made as necessary, and by a qualified contractor if necessary so windows open fully, and open and close easily.
    61) Screen(s) in one or more windows are torn or have holes in them. Screens should be replaced where necessary.
    62) One or more interior doors are damaged and/or deteriorated and should be repaired or replaced by a qualified contractor.
    63) Trim is missing in one or more areas. Recommend having a qualified contractor install trim where missing.

    Photo 22  
     

    64) Fixtures such as door stops, towel bars and/or toilet paper holders are missing in one or more areas. Recommend having a qualified contractor install fixtures where missing.
    65) One or more air supply registers are missing. The air flow cannot be controlled as a result. Registers should be installed where missing.
    66) Screen(s) in one or more windows are torn or have holes in them. Screens should be replaced where necessary.
    67) One or more interior doors are damaged and/or deteriorated and should be repaired or replaced by a qualified contractor.
    68) Fixtures such as door stops, towel bars and/or toilet paper holders are missing in one or more areas. Recommend having a qualified contractor install fixtures where missing.
    69) Recommend cleaning and sealing grout in tile or stone flooring now and in the future as necessary to prevent staining and to improve waterproofing.
    70) Recommend cleaning and sealing grout in tile or stone flooring now and in the future as necessary to prevent staining and to improve waterproofing.
    71) Minor cracks were found in walls in one or more areas. They do not appear to be a structural concern, but the client(s) may wish to repair these for aesthetic reasons.
     

    Photo 4  

    Photo 8  
    Main water shut off

    Photo 9  

    Photo 10  

    Photo 11  

    Photo 12  

    Photo 13  
    Possible termite damage.

    Photo 14  

    Photo 15  
    improper wiring

    Photo 16  
    improper plumbing

    Photo 17  

    Photo 18  

    Photo 20  

    Photo 21  

    Photo 23  

    Photo 26  

    Photo 27  

    Photo 28  

    Photo 29  

    Photo 30  
    pipes deteriorating

    Photo 32  

    Photo 33  

    Photo 34  

    Photo 35  

    Photo 36