Website: http://www.reporthost.com/maintenance
Email: mikekbrook@aol.com
Phone: (440) 317-0134
FAX: (440) 439-9406
694 Archer Rd. Bedford Ohio 44146
Inspector: Michael Kreinbrook

 

BECAUSE YOU CAN'T EXPECT WHAT YOU DON'T INSPECT
Client(s): Sample Report
Property address: your home
Inspection date: Monday March 9,Tuesday, March 10, 2009
This report published on 11/30/2009 10:31:25 PM EST

View summary page

This report is the exclusive property of this inspection company and the client(s) listed in the report title. Use of this report by any unauthorized persons is prohibited.

 
How to Read this Report
This report is organized by the property's functional areas.  Within each functional area, descriptive information is listed first and is shown in bold type.  Items of concern follow descriptive information.
Concerns are shown and sorted according to these types:
SafetyPoses a risk of injury or death 
Major DefectCorrection likely involves a significant expense 
Repair/ReplaceRecommend repairing or replacing 
Repair/MaintainRecommend repair and/or maintenance 
Minor DefectCorrection likely involves only a minor expense 
MaintainRecommend ongoing maintenance 
EvaluateRecommend evaluation by a specialist 
MonitorRecommend monitoring in the future 
CommentFor your information 

Click here for a glossary of building construction terms.  Contact your inspector if there are terms that you do not understand, or visit the glossary of construction terms at http://www.reporthost.com/glossary.asp

Table of Contents
General information
Exterior 7403
Roof
Garage
Electric service
Water heater
Heating and cooling
Plumbing and laundry
Basement
Kitchen
Interior rooms
Exterior 1179
Exterior
Exterior E
Roof E147
Basement E147
 
General information Return to table of contents
Report number: 00000000
Type of building: Single family, Duplex
Property owner's name: XXXXXX
Occupied: No
Weather conditions: Cloudy, Rain
Temperature: Cold
Ground condition: Wet
Foundation type: Unfinished basement
1) Structures built prior to 1979 may contain lead-based paint and/or asbestos in various building materials such as insulation, siding, and/or floor and ceiling tiles. Both lead and asbestos are known health hazards. Evaluating for the presence of lead and/or asbestos is not included in this inspection. The client(s) should consult with specialists as necessary, such as industrial hygenists, professional labs and/or abatement contractors for this type of evaluation. For information on lead, asbestos and other hazardous materials in homes, visit these websites:
  • The Environmental Protection Association (http://www.epa.gov)
  • The Consumer Products Safety Commission (http://www.cpsc.gov)
  • The Center for Disease Control (http://www.cdc.gov)
    2) The natural gas service was turned off. As a result, some appliances such as water heater(s), forced air furnace(s), gas fireplace(s), stove(s), range(s) and/or gas supply lines weren't fully evaluated. The inspector was unable to test for gas leaks.
    3) The water service wasn't turned on during the inspection. As a result, plumbing supply, drain and waste lines, fixtures, and some appliances such as water heaters weren't fully evaluated.
    4) Electricity was not available during the inspection (service turned off or not fully installed, main disconnect tripped, etc.). As a result, branch circuit wiring, fixtures such as lights and fans, switches, ground fault circuit interrupter (GFCI) devices, arc fault circuit interrupter (AFCI) devices, and some appliances such as water heaters, forced air furnaces, heat pump or air conditioning units, and kitchen appliances weren't fully evaluated.
    5)  

    Photo 1  

    Photo 2  

    6)   The general info applies to all four properties inspected
     
    Exterior 7403 Return to table of contents
    Foundation material: Stone
    Apparent wall structure: Wood frame
    Wall covering: Metal
    Exterior door material: Solid core wood
    7) Cracks, deterioration and/or damage were found in one or more areas of the stucco siding on foundation. A qualified contractor should evaluate and make repairs and/or replace stucco siding as necessary.

    Photo 3  
     

    8) Siding is incomplete or missing in one or more areas. A qualified contractor should install siding where missing to prevent water and vermin intrusion.

    Photo 25  
     

    9) One or more moderate cracks (1/8 inch to 3/4 inch) were found in the foundation. These may be a structural concern, or an indication that settlement is ongoing. The client(s) should consider hiring qualified contractors and/or engineers as necessary for further evaluation. Such contractors may include:

  • Foundation repair contractors who may prescribe repairs, and will give cost estimates for prescribed repairs
  • Masonry contractors who repair and/or replace brick veneer
  • Geotechnical engineers who attempt to determine if settlement is ongoing, and what the cause of the settlement is
  • Structural engineers who determine if repairs are necessary, and prescribe those repairs

    At a minimum, recommend sealing cracks to prevent water infiltration. Numerous products exist to seal such cracks including:
  • Hydraulic cement. Requires chiseling a channel in the crack to apply. See http://www.quickrete.com/catalog/HydraulicWater-StopCement.html for an example.
  • Resilient caulks (easy to apply). See http://www.quickrete.com/catalog/GrayConcreteRepair.html for an example.
  • Epoxy sealants (both a waterproof and structural repair). See http://www.mountaingrout.com/ for examples of these products.
    10) Caulk is missing or deteriorated in some areas and should be replaced and/or applied where necessary. For more information on caulking, visit The Ins and Outs of Caulking.
     
    Roof Return to table of contents
    Roof inspection method: Viewed from ground with binoculars
    Roof type: Gable
    Roof covering: Asphalt or fiberglass composition shingles
    Gutter & downspout material: Aluminum
    Roof inspection method: Viewed from ground with binoculars
    11) This asphalt or fiberglass composition roof surface has two or more layers of roofing materials. When this roof is replaced, recommend a complete "tear off", where all existing layers of roofing are removed before installing new roofing materials. For 20-year rated composition shingles, additional layers of material reduce the new roof material's lifespan as follows:

  • 16-20 years - First roof
  • 12-16 years - Second layer on existing roof

    Removing existing roofing materials will significantly increase the cost of the next roof.
    12) One or more sections of flashing at the base of the chimney are deteriorated and/or substandard. Leaks may occur as a result. A qualified roofing contractor should evaluate and repair as necessary.

    Photo 23  

    Photo 24  

    13) One or more composition shingles have raised, most likely due to nails that have loosened. Leaks may occur as a result. A qualified roofing contractor should evaluate and make repairs as necessary, such as reseating nails.
    14) One or more sections of flashing at the base of the chimney are deteriorated and/or substandard. Leaks may occur as a result. A qualified roofing contractor should evaluate and repair as necessary.
    15)   the roof appears to have been recently installed, However the quality of craftsmanship is insufficient in several areas, raised shingles, no flashing and other defects are visible. I found what appears to be mold on a bedroom ceiling but could not determine if this was an active leak

    Photo 5  
     
     
    Garage Return to table of contents

    16) back wall of garage has been severely damaged. the other walls have light to moderate cracking or damage

    Photo 21  

    Photo 22  
     
    Electric service Return to table of contents
    Primary service type: Overhead
    Service amperage (amps): 60
    Service voltage (volts): 120/240
    17) most of the electrical in basement has been removed by thieves. some areas in the living space has damaged areas where electrical wire has been removed

    Photo 16  
    note the cut wire on left side of box
     
     
    Water heater Return to table of contents

    18) tank appears to be beyond usable condition, supply plumbing has been removed

    Photo 12  
     
     
    Heating and cooling Return to table of contents

    19)   Furnace has been stripped of several control parts as well as the sheet metal air supply

    Photo 15  
     
     
    Plumbing and laundry Return to table of contents
    Supply pipe material: CPVC most supply pipes are eather damaded or have been removed
    Drain pipe material: Plastic, Cast iron
    Waste pipe material: Plastic, Cast iron
    20)   CPVC most supply pipes are ether damaged or have been removed

    Photo 8  

    Photo 13  

    Photo 14  
     
     
    Basement Return to table of contents
    Insulation material underneath floor above: None visible
    Pier or support post material: Bearing wall, Masonry, Steel
    Floor structure above: Solid wood joists
    21) similar to photo below several areas in the beams, joists rim joist and sole plate show light to heavy damage and rot. There has been some improper attempts to make repairs with steel posts, and to correct the floor slope.
    22) Evidence of prior water intrusion was found in one or more sections of the basement. For example, water stains and/or efflorescence on the foundation or floor, water stains at bases of support posts, etc. Accumulated water is a conducive condition for wood destroying insects and organisms and should not be present in the basement. The client(s) should review any disclosure statements available and ask the property owner(s) about past accumulation of water in the basement. The basement should be monitored in the future for accumulated water, especially after heavy and/or prolonged periods of rain. If water is found to accumulate, a qualified contractor who specializes in drainage issues should evaluate and repair as necessary. Typical repairs for preventing water from accumulating in the basement include:

  • Repairing, installing or improving rain run-off systems (gutters, downspouts and extensions or drain lines)
  • Improving perimeter grading
  • Repairing, installing or improving underground footing and/or curtain drains

    Ideally, water should not enter the basement, but if water must be controlled after it enters the basement, then typical repairs include installing sump pump(s) or interior perimeter drains.

    Photo 17  
     

    23) Standing water and/or wet areas were found in one or more sections of the basement. Accumulated water is a conducive condition for wood destroying insects and organisms and should not be present in the basement. A qualified contractor who specializes in drainage issues should evaluate and repair as necessary. Typical repairs for preventing water from accumulating in the basement include:

  • Repairing, installing or improving rain run-off systems (gutters, downspouts and extensions or drain lines)
  • Improving perimeter grading
  • Repairing, installing or improving underground footing and/or curtain drains

    Ideally, water should not enter the basement, but if water must be controlled after it enters the basement, then typical repairs include installing sump pump(s) or interior perimeter drains.
     
    Kitchen Return to table of contents

    24) One or more cabinets and/or drawers are damaged and/or deteriorated. A qualified contractor should evaluate and repair or replace cabinets and/or components as necessary.

    Photo 7  
     

    25) Shelving or other components are missing from one or more cabinets. Missing shelving and/or components should be replaced, and by a qualified contractor if necessary.
    26) Water damage was found in the shelving or cabinet components below one or more sinks. A qualified contractor should evaluate and make repairs as necessary.
    27) Vinyl flooring is damaged and/or deteriorated in one or more areas. A qualified contractor should replace or repair the damaged flooring.

    Photo 20  
     
     
    Interior rooms Return to table of contents

    28) One or more light fixtures or lamp holders appear to be very old and may have brittle and/or deteriorated insulation. This is a safety hazard due to the risk of shock and/or fire. A qualified electrician should evaluate and replace old fixtures as necessary.
    29) One or more light fixtures or lamp holders appear to be very old and may have brittle and/or deteriorated insulation. This is a safety hazard due to the risk of shock and/or fire. A qualified electrician should evaluate and replace old fixtures as necessary.
    30) No smoke alarms are visible. This is a safety hazard. A qualified electrician should install smoke alarms as per standard building practices (functioning one exists in hallways leading to bedrooms, and in each bedroom, etc.). For more information, visit http://www.cpsc.gov/cpscpub/pubs/5077.html
    31) One or more electric receptacles are broken or damaged. This is a safety hazard due to the risk of fire and shock. A qualified electrician should replace them as necessary.
    32) Carpeting in one or more rooms is loose and poses a trip hazard. A qualified carpeting installation contractor should re stretch or replace carpet as necessary.

    Photo 18  

    Photo 19  

    33) Cover plate(s) are missing from one or more electric boxes, such as for receptacles, switches and/or junction boxes. They are intended to contain fire and prevent electric shock from exposed wires. This is a safety hazard due to the risk of fire and shock. Cover plates should be installed where missing.
    34) Screen(s) in one or more windows are missing. The client(s) should ask the property owner(s) about this. Screens are often removed for window cleaning and they may be stored somewhere. If not, then recommend installing screens where missing.
    35) One or more deadbolt mechanisms are inoperable or difficult to operate. A qualified contractor should evaluate and repair as necessary.
    36) Floors in one or more areas are not level. Significant repairs may be needed to make floors level, such as repairs to the foundation. A qualified contractor should evaluate and make repairs as necessary.
    37) One or more light fixtures are damaged and/or deteriorated. A qualified electrician should evaluate and repair or replace light fixtures where necessary.
    38) Floors in one or more areas are not level. Significant repairs may be needed to make floors level, such as repairs to the foundation. A qualified contractor should evaluate and make repairs as necessary.
    39) Floor tiles installed in "wet" areas have gaps between them. The wooden subfloor beneath may be damaged by water intrusion. A qualified contractor should evaluate, make repairs if necessary, and replace flooring with a waterproof floor such as sheet vinyl in wet areas.
    40) One or more air supply registers are missing. The air flow cannot be controlled as a result. Registers should be installed where missing.
    41) Lock mechanisms on one or more windows are missing and/or damaged so that they are inoperable. Repairs should be made by a qualified contractor or service technician so that windows lock and unlock easily.
    42) Glass in one or more windows is broken. A qualified contractor should replace glass where necessary.

    Photo 11  
     

    43) Screen(s) in one or more windows are torn or have holes in them. Screens should be replaced where necessary.
    44) One or more interior doors are damaged and/or deteriorated and should be repaired or replaced by a qualified contractor.
    45) One or more exterior entrance doors are damaged and/or deteriorated and should be repaired or replaced by a qualified contractor.

    Photo 7  

    Photo 10  

    46) Vinyl flooring is damaged and/or deteriorated in one or more areas. A qualified contractor should replace or repair the damaged flooring.
    47) Carpeting in one or more rooms is damaged and/or significantly deteriorated. Recommend replacing carpeting where necessary.
    48) Trim is damaged and/or deteriorated in one or more areas. Recommend having a qualified contractor replace or repair trim as necessary.
    49) Fixtures such as door stops, towel bars and/or toilet paper holders are missing in one or more areas. Recommend having a qualified contractor install fixtures where missing.
    50) Fixtures such as door stops, towel bars and/or toilet paper holders are damaged and/or deteriorated in one or more areas. Recommend having a qualified contractor replace or repair fixtures as necessary.
    51) One or more air supply registers are missing. The air flow cannot be controlled as a result. Registers should be installed where missing.
    52) Glass in one or more windows is broken. A qualified contractor should replace glass where necessary.
    53) Screen(s) in one or more windows are torn or have holes in them. Screens should be replaced where necessary.
    54) One or more interior doors are damaged and/or deteriorated and should be repaired or replaced by a qualified contractor.
    55) One or more exterior entrance doors are damaged and/or deteriorated and should be repaired or replaced by a qualified contractor.
    56) Vinyl flooring is damaged and/or deteriorated in one or more areas. A qualified contractor should replace or repair the damaged flooring.
    57) Carpeting in one or more rooms is loose. Recommend having a qualified carpeting installation contractor restretch carpet as necessary.
    58) Trim is missing in one or more areas. Recommend having a qualified contractor install trim where missing.
    59) Fixtures such as door stops, towel bars and/or toilet paper holders are missing in one or more areas. Recommend having a qualified contractor install fixtures where missing.
    60) Fixtures such as door stops, towel bars and/or toilet paper holders are damaged and/or deteriorated in one or more areas. Recommend having a qualified contractor replace or repair fixtures as necessary.
    61) One or more light fixtures appear to be inoperable. Recommend further evaluation by replacing bulb(s) and/or consulting with the property owner(s). Repairs or replacement of the light fixture(s) by a qualified electrician may be necessary.
    62) Stains were found in one or more ceiling areas. However, no elevated levels of moisture were found. The stain(s) may be due to past roof and/or plumbing leaks. Recommend asking the property owner(s) about this, and monitoring the stained area(s) in the future, especially after heavy or prolonged rain. If elevated moisture is found in the future, a qualified contractor should evaluate and repair as necessary.
    63) Minor cracks were found in walls in one or more areas. They do not appear to be a structural concern, but the client(s) may wish to repair these for aesthetic reasons.

    Photo 4  

    Photo 6  

    64) Minor cracks were found in ceilings in one or more areas. They do not appear to be a structural concern, but the client(s) may wish to repair these for aesthetic reasons.
    65) Minor cracks were found in walls in one or more areas. They do not appear to be a structural concern, but the client(s) may wish to repair these for aesthetic reasons.
     
    Exterior 1179 Return to table of contents
    Foundation material: Concrete block
     
    Exterior Return to table of contents
    Foundation material: Concrete block
    Apparent wall structure: Wood frame
    Wall covering: Cement-based clapboard
     
    Interior rooms Return to table of contents

    66) One or more exterior entrance doors are damaged and/or deteriorated and should be repaired or replaced by a qualified contractor.
     
    Exterior E Return to table of contents
    Foundation material: Concrete block, Brick
    Apparent wall structure: Wood frame
    Wall covering: Stucco
    Driveway material: ashphalt
    Exterior door material: Solid core steel
    67) One or more sets of stairs are wobbly. A qualified contractor should evaluate and repair as necessary, such as installing additional supports and/or diagonal bracing.
    68) Property was unsecured as I arrived on site. changed lock on side door
    69) Cracks, deterioration and/or damage were found in one or more areas of the stucco siding. A qualified contractor should evaluate and make repairs and/or replace stucco siding as necessary.

    Photo 60  

    Photo 61  

    Photo 62  

    Photo 71  

    70) Fascia boards are damaged or deteriorated in one or more areas. A qualified contractor should evaluate and make repairs as necessary.

    Photo 69  

    Photo 73  

    71) One or more moderate cracks (1/8 inch to 3/4 inch) were found in the foundation. These may be a structural concern, or an indication that settlement is ongoing. The client(s) should consider hiring qualified contractors and/or engineers as necessary for further evaluation. Such contractors may include:

  • Foundation repair contractors who may prescribe repairs, and will give cost estimates for prescribed repairs
  • Masonry contractors who repair and/or replace brick veneer
  • Geotechnical engineers who attempt to determine if settlement is ongoing, and what the cause of the settlement is
  • Structural engineers who determine if repairs are necessary, and prescribe those repairs

    At a minimum, recommend sealing cracks to prevent water infiltration. Numerous products exist to seal such cracks including:
  • Hydraulic cement. Requires chiseling a channel in the crack to apply. See http://www.quickrete.com/catalog/HydraulicWater-StopCement.html for an example.
  • Resilient caulks (easy to apply). See http://www.quickrete.com/catalog/GrayConcreteRepair.html for an example.
  • Epoxy sealants (both a waterproof and structural repair). See http://www.mountaingrout.com/ for examples of these products.
    72) Caulk is missing or deteriorated in some areas and should be replaced and/or applied where necessary. For more information on caulking, visit The Ins and Outs of Caulking.
     
    Roof E147 Return to table of contents
    Roof inspection method: Viewed from ground with binoculars
    Roof covering: Asphalt or fiberglass composition shingles
    73) One or more sections of roof flashing are deteriorated and/or rusted. Leaks may occur as a result. A qualified roofing contractor should evaluate and replace flashing where necessary.
    74) One or more sections of flashing at the base of the chimney are deteriorated and/or substandard. Leaks may occur as a result. A qualified roofing contractor should evaluate and repair as necessary.

    Photo 68  
     
     
    Basement E147 Return to table of contents

    75) Wooden support posts are not securely fastened to beams above. and some have rot at the bottom. This is a safety hazard since they can separate during a seismic event. A qualified contractor should evaluate and make repairs as necessary, such as installing metal ties, bracing with lumber and/or plywood gussets as per standard building practices.

    Photo 74  
     

    76) Standing water and/or wet areas were found in one or more sections of the basement.It was raining at time of inspection, and water was flowing in very quickly Major leaking. I was not able to determine how water was entering. Accumulated water is a conducive condition for wood destroying insects and organisms and should not be present in the basement. A qualified contractor who specializes in drainage issues should evaluate and repair as necessary. Typical repairs for preventing water from accumulating in the basement include:

  • Repairing, installing or improving rain run-off systems (gutters, downspouts and extensions or drain lines)
  • Improving perimeter grading
  • Repairing, installing or improving underground footing and/or curtain drains

    Ideally, water should not enter the basement, but if water must be controlled after it enters the basement, then typical repairs include installing sump pump(s) or interior perimeter drains.

    Photo 78  
     

    77)   water is leaking into basement, in several areas, many of the floor joists show rot and what appears to be mold. there has been some attempts to repair the joists, However improperly new joists are sister ed to the old but they are not supported at the ends. as the original joists continue to rot there will be nothing to prevent them from further sagging

    Photo 77  

    Photo 79  

    Photo 90  
     

    78)   Boiler has been stripped, as well as the plumbing, and electric. All radiators and base board heating has been removed

    Photo 82  

    Photo 86  
     
    Interior rooms Return to table of contents

    79) Evidence of "light to moderate" rodent infestation was found in one or more areas.(possible Raccoon) Rodent infestation may be a safety hazard due to the risk of contracting Hantavirus Pulmonary Syndrome (HPS). HPS is a rare (only 20-50 cases per year in the United states) but deadly (40% mortality rate) disease transmitted by infected rodents through urine, droppings, or saliva. Humans can contract the disease when they breathe in aerosolized virus. For example, from sweeping up rodent droppings.

    Recommend following guidelines in the CDC's Clean Up, Trap Up, Seal Up article for eradicating rodents, cleaning up their waste and nesting materials, and preventing future infestations. While Hanta virus is believed to survive less than one week in droppings and urine, specific precautions should be taken during clean up. The client(s) may wish to consult with a qualified, licensed pest control operator for eliminating the infestation. A qualified licensed abatement contractor or industrial hygenist could be contacted for clean up. If the infestation was minimal, clean up of rodent waste and nesting materials in non-living spaces (crawl spaces and attics) may not be necessary, or may be performed for aesthetic reasons only (odor and appearance).

    Photo 87  
     

    80) One or more electric baseboard heaters are damaged or deteriorated. For example, missing, bent or loose metal panels. A qualified electrician should evaluate and repair or replace heaters as necessary.

    Photo 63  

    Photo 64  

    81) Glass in one or more windows is broken. A qualified contractor should replace glass where necessary.

    Photo 59  

    Photo 70  

    Photo 72  
     

    82) Carpeting in one or more rooms is damaged and/or significantly deteriorated. Recommend replacing carpeting where necessary.

    Photo 80  

    Photo 85  

    83) Minor cracks were found in walls in one or more areas. They do not appear to be a structural concern, but the client(s) may wish to repair these for aesthetic reasons.

    Photo 75  

    Photo 76  

    Photo 91  
     
     

    Photo 9  

    Photo 26  

    Photo 27  

    Photo 28  

    Photo 29  

    Photo 30  

    Photo 31  

    Photo 32  

    Photo 33  

    Photo 34  

    Photo 35  

    Photo 36  

    Photo 37  

    Photo 38  

    Photo 39  
    damage to ceiling downstairs kitchen

    Photo 40  

    Photo 41  

    Photo 42  

    Photo 43  

    Photo 44  

    Photo 45  

    Photo 46  

    Photo 47  

    Photo 48  

    Photo 49  

    Photo 50  

    Photo 51  

    Photo 52  

    Photo 53  

    Photo 54  

    Photo 55  

    Photo 56  

    Photo 57  

    Photo 58  

    Photo 65  

    Photo 66  

    Photo 67  

    Photo 81  

    Photo 83  

    Photo 84  

    Photo 88  

    Photo 89  

     


    http://www.maintenanceinnovations.com