Website: http://www.Look1st.net
Email: look1st@sbcglobal.net
Phone: (530) 864-6809 · (530) 877-2000
FAX: (866) 240-2869
490 Boquest Blvd. 
Paradise, Ca. 95969
Inspector: Steven Waterman
NACHI #06092992
HIF # 10368A

 

Sepongviwat / Notting Hill Inspection
Client(s): Tony & Vanesa Sepongviwat
Property address: 1716 Notting Hill Way
Plumas Lake, Ca. 95961
Inspection date: Saturday, February 21, 2009
This report published on 2/21/2009 9:03:34 PM PST

View summary page

NOTE:

The findings and recommendations contained in this report are based on the newest and most up to date construction and safety standards in the industry. Some deficiencies may not have been recognized as such at the time the structure was built or remodeled. Other deficiencies are aimed at energy efficiency or air quality, and are not required building restrictions or practices.

Look First Inspections is not a specialist in code compliance or zoning restrictions, and no part of the report should be considered as required repair and/or replacement.

 
How to Read this Report
This report is organized by the property's functional areas.  Within each functional area, descriptive information is listed first and is shown in bold type.  Items of concern follow descriptive information. Concerns are shown and sorted according to these types:
SafetyPoses a risk of injury or death 
Repair/MaintainRecommend repair and/or maintenance 
Minor DefectCorrection likely involves only a minor expense 
MaintainRecommend ongoing maintenance 
EvaluateRecommend evaluation by a specialist 
ServiceableItem or component is in servicable condition 
CommentFor your information 

Structural Pest Inspection Concerns
Items of concern relating to the structural pest inspection are shown as follows:
WDO/WDI InfestationEvidence of infestation of wood destroying insects or organisms (Live or dead insect bodies, fungal growth, etc.) 
WDO/WDI DamageDamage caused by wood destroying insects or organisms (Rot, carpenter ant galleries, etc.) 
WDO/WDI Conducive
conditions
Conditions conducive for wood destroying insects or organisms (Wood-soil contact, shrubs in contact with siding, roof or plumbing leaks, etc.) 

Click here for a glossary of building construction terms.  Contact your inspector if there are terms that you do not understand, or visit the glossary of construction terms at http://www.reporthost.com/glossary.asp

Table of Contents
General Information
Grounds
Exterior / Foundation
Roof / Attic
Garage / Carport
Electric
Plumbing / Fuel Systems
Water Heater
Heating
Cooling / Heat Pump
Fireplaces / Stoves / Chimneys
Kitchen
Bathrooms / Laundry / Sinks
Interior Rooms / Areas
 
General Information Return to table of contents
Report number: 1164
Time started: 8:30 am
Time finished: 10:30 am
Client present for discussion at end of inspection: Yes
Weather conditions: Partly cloudy
Temperature: Cool
Ground condition: Damp
Type of building: Single family
Age of building(s): 4 years
Source for building age: Municipal records
Front of building faces: East
Occupied: No


1)   Evidence of pigeon roosting was found on the roof in the form of nest(s), feces and live pigeons.
Pigeons are a nuisance and can be a health hazard.
Recommend consulting with a licensed pest control operator for contol or exclusion of pigeons.

Photo 2  
Above front door, South side

Photo 9  

 
Grounds Return to table of contents
Limitations: The following items are not included in this inspection: swimming pools, spas, hot tubs, water features and related equipment; playground, recreation or leisure equipment; landscape lighting; areas below exterior structures with less than three feet of vertical clearance; irrigation systems; invisible fencing; sea walls, docks and boathouses. Any comments made regarding these items are as a courtesy only. Note that the inspector does not test or determine the adequacy of drainage systems for grounds, walkways, below-grade stairs and roof downspouts. The inspector does not provide an evaluation of geological conditions and/or site stability, compliance of pool or spa fencing with municipal requirements, or determination that deck, balcony and/or stair membranes are watertight.
Condition of fences and gates: Appeared serviceable
Fence and gate material: Wood
Site profile: Level
Condition of driveway: Appeared serviceable
Driveway material: Poured in place concrete
Condition of sidewalks and/or patios: Appeared serviceable
Sidewalk material: Poured in place concrete
Condition of deck, patio and/or porch covers: Appeared serviceable
Deck, patio, porch cover material and type: Covered (Refer to Roof section)
2) Vegetation such as trees, shrubs and/or vines was in contact with or less than one foot from the building exterior. Vegetation can serve as a conduit for wood destroying insects and may retain moisture against the exterior after it rains. Vegetation should be pruned and/or removed as necessary to maintain a one foot clearance between it and the building exterior.

Photo 6  
East side
 

 
Exterior / Foundation Return to table of contents
Limitations: The following items are not included in this inspection: below-grade foundation walls and footings, or those obscured by vegetation or building components; exterior building surfaces or components obscured by vegetation, stored items or debris. Any comments made regarding these items are as a courtesy only. Some amount of cracking is normal in concrete slabs and foundation walls due to shrinkage and drying. Note that the inspector does not determination the adequacy of sump pumps, seismic reinforcement, nor determine if support posts, columns, beams, joists, studs, trusses, etc. are of adequate size, spanning or spacing.
Condition of wall covering: Appeared serviceable
Apparent wall structure: Wood frame
Wall covering: Stucco
Condition of foundation and footings: Appeared serviceable
Foundation type: Slab on grade
Foundation material: Poured in place concrete
Condition of concrete slab floor(s): Appeared serviceable
3)   Minor deterioration and/or damage were found in one or more areas of the stucco siding.

Photo 7  
East side

Photo 8  
NE corner

4)   All concrete slab floor sections were obscured by carpeting, flooring and couldn't be fully evaluated.
 
Roof / Attic Return to table of contents
Limitations: The following items or areas are not included in this inspection: areas that could not be traversed or viewed clearly due to lack of access; areas and components obscured by insulation; solar roofing components; any comments made regarding these items are as a courtesy only. Note that the inspector does not determination if rafters, trusses, joists, beams, etc. are of adequate size, spanning or spacing. The inspector does not provide an estimate of remaining roof surface life, does not determine that the roof has absolutely no leaks at the time of the inspection, and does not determine that the roof won't leak in the future. Only active leaks and evidence of past leaks observed during the inspection are reported on as part of this inspection. To absolutely determine than no leaks exist, complete access to all roof structure areas must be available during a wide variety of weather conditions, including prolonged heavy rain, high wind from varying directions, heavy accumulations of snow and/or ice, and melting snow and ice.
Condition of roof structure: Appeared serviceable
Roof type: Gable
Age of roof surface(s): 4 years
Roof inspection method: Viewed from eaves on ladder, Viewed from ground with binoculars
Condition of metal and/or tile roof surface materials: Appeared serviceable
Metal, tile or panel roof surface material: Concrete tile
Condition of exposed flashings: Appeared serviceable
Condition of gutters, downspouts and extensions: Required repair, replacement and/or evaluation (see comments below)
Gutter and downspout material: Metal
Gutter and downspout installation: Full
Condition of attic: Appeared serviceable
Attic inspection method: Traversed
Roof structure type: Trusses
Ceiling insulation material: Cellulose loose fill
Ceiling insulation depth: 8" to 10"
Vapor retarder: None
Roof ventilation: Appears serviceable
5)   Some downspouts were damaged. Water may accumulate around the building foundation as a result. A qualified person should evaluate and repair as necessary.

Photo 10  
SW corner
 

6)   Because of the roof covering type, the inspector was unable to traverse the roof and wasn't able to fully evaluate the entire roof.
 
Garage / Carport Return to table of contents
Limitations: The inspector does not determine the adequacy of firewall ratings. Requirements for ventilation in garages varies between municipalities.
Type: Attached
Condition of garage/dwelling door: Appeared serviceable
Condition of garage vehicle door(s): Appeared serviceable
Garage vehicle door type: Sectional
Number of vehicle doors: 1
Condition of automatic opener(s): Appeared serviceable
Condition of garage floor: Appeared serviceable
Condition of garage interior: Appeared serviceable
Garage ventilation: Exists
 
Electric Return to table of contents
Limitations: The following items are not included in this inspection: generator systems, surge suppressors, inaccessible or concealed wiring; underground utilities and systems; low voltage lighting or lighting on timers or sensors. Any comments made regarding these items are as a courtesy only. Note that the inspector does not determine the adequacy of grounding or bonding, does not determine if this system has an adequate capacity for the client's specific needs, nor determine if this system has any reserve capacity for additions or expansion. The inspector does not operate circuit breakers as part of the inspection, install or change light bulbs, nor determine the operability of every wall switch.
Electric service condition: Appeared serviceable
Primary service type: Underground
Number of service conductors: 3
Service voltage (volts): 120/240
Service amperage (amps): 200
Primary service overload protection type: Circuit breakers
Service entrance conductor material: Copper
Main disconnect rating (amps): 200
System ground: Unable to determine
Condition of main service panel: Appeared serviceable
Location of main service panel #A: Building exterior, at SE corner
Branch circuit wiring type: Nonmetallic sheathed
Condition of branch circuit wiring: Serviceable
Condition of smoke detectors: Required repair, replacement and/or evaluation (see comments below)
Smoke detectors present: Yes
Carbon monoxide detectors present: No
Smoke detector power source: Hard wired
7)   Some cover plates on receptacle, switch boxes were broken, loose. They are intended to contain fire and prevent electric shock from exposed wires. This is a safety hazard due to the risk of fire and shock. A qualified person should repair as necessary.

Photo 17  
Living room, North wall
 

8)   This property had one or more fuel burning appliances and/or an attached garage, and no carbon monoxide detectors were visible. This is a safety hazard. Recommend installing one or more carbon monoxide detectors as necessary and as per the manufacturer's instructions. For more information, visit http://www.cpsc.gov/CPSCPUB/PREREL/prhtml05/05017.html
9)   Batteries in all the smoke alarms should be replaced after taking occupancy, and annually in the future. "Chirping" noises emitted from smoke alarms typically indicate that batteries need replacing. For more information, visit http://www.cpsc.gov/cpscpub/pubs/5077.html
10)   Some bulbs in light fixtures were inoperable, broken. As a result, some light fixtures couldn't be fully evaluated. Recommend replacing bulbs to fully evaluate fixtures where necessary.

Photo 13  
Above furnace

Photo 16  
East side by front door

Photo 18  
Dining room

Photo 19  
Master bedroom

 
Plumbing / Fuel Systems Return to table of contents
Limitations: The following items are not included in this inspection: private wells and sewage disposal systems; main, side and lateral sewer lines; gray water systems; pressure boosting systems; incinerating or composting toilets; fire suppression sprinkler systems; water softeners, conditioners or filtering systems; plumbing components concealed within the foundation or building structure, or in inaccessible areas such as below tubs; underground utilities and systems; overflow drains for tubs and sinks; backflow prevention devices. Any comments made regarding these items are as a courtesy only. Note that the inspector does not operate water supply or shut-off valves due to the possibility of valves leaking or breaking when operated. The inspector does not test for lead in the water supply, the water pipes or solder, does not determine if plumbing and fuel lines are adequately sized, and does not determining the existence or condition of underground or above-ground fuel tanks.
Condition of service and main line: Required repair, replacement and/or evaluation (see comments below)
Location of main water meter: NE corner of lot by street
Location of main water shut: East side
Water service: Public
Service pipe material: Copper
Condition of supply lines: Appeared serviceable
Supply pipe material: Polyethylene
Condition of waste lines: Appeared serviceable
Waste pipe material: Plastic
Condition of fuel system: Appeared serviceable
Location of main fuel shut: SE corner
11)   The water shut-off valve for the irrigation system was in contact with the soil below. Corrosion is more likely to occur as a result. Soil should be graded, or modifications made as necessary so the valve is not in contact with the soil below.
12)   Water supply lines were routed outside and are subject to freezing. Pipe wrap or foam sleeves are inexpensive and easily installed. Recommend insulating pipes as necessary to prevent pipes from freezing and bursting.

Photo 20  
East side
 

13)   Some water supply pipes in the attic were uninsulated. Recommend insulating pipes as per standard building practices for better energy efficiency.

Photo 11  

Photo 12  

14)   The water service was not turned on during the inspection. As a result, plumbing supply, drain and waste lines, fixtures, and some appliances such as water heaters weren't fully evaluated. Recommend that a full evaluation of the plumbing system be made after the water supply is turned back on.
 
Water Heater Return to table of contents
Limitations: The following items are not included in this inspection: solar water heating systems; circulation systems. Any comments made regarding these items are as a courtesy only. Note that the inspector does not provide an estimate of remaining life on water heaters, does not determine if water heaters are appropriately sized, or perform any evaluations that require a pilot light to be lit.
Condition of water heater: Required repair, replacement and/or evaluation (see comments below)
Type: Tank
Estimated age: 4 years
Energy source: Natural gas
Capacity (in gallons): 40
Manufacturer: A.O. Smith
Model: GVR 40 100, ser# A05J004296
Location of water heater: Garage
Condition of burners: Not evaluated
Condition of venting system: Appeared serviceable
Condition of combustion air supply: Appeared serviceable
15)   This water heater was not fully evaluated because the following condition(s) existed: pilot light off, water supply off. Recommend that a full evaluation be made by a qualified person when conditions have been corrected so the appliance is operable. Note that as per the standards of practice for NACHI (http://www.nachi.org) and ASHI (www.ashi.org), the inspector is not required to operate shut-off valves, pilot lights or overcurrent protection devices, or any controls other than "normal controls".
16)   Based on the capacity of the water heater, the number of bedrooms in this structure and the number of occupants expected to live in this structure, this water heater may be undersized. The client should consult with a qualified plumbing contractor or water heater distributor for more information, and may wish to upgrade the size of the water heater.
 
Heating Return to table of contents
Limitations: The following items are not included in this inspection: humidifiers, dehumidifiers, electronic air filters; solar, coal or wood fired heat systems; thermostat or temperature control accuracy and timed functions; heating components concealed within the building structure or in inaccessible areas; underground utilities and systems; safety devices and controls (due to automatic operation). Any comments made regarding these items are as a courtesy only. Note that the inspector does not provide an estimate of remaining life on heating system components, does not determine if heating systems are appropriately sized, or perform any evaluations that require a pilot light to be lit. It is beyond the scope of this inspection to determine if furnace heat exchangers are intact and free of leaks.
Condition of heating system: Appeared serviceable
Location of heating system: Attic
Heating type: Forced air
Fuel type: Natural gas
Manufacturer: Carrier
Last service date: Unknown
Model: 58STX110-12122, ser# 1705A40569
Condition of burners: Appeared serviceable
Condition of venting system: Appeared serviceable
Condition of combustion air supply: Appeared serviceable
Condition of distribution system: Appeared serviceable
Distribution system: Ducts and registers
Condition of controls: Appeared serviceable
Condition of air filters: Appeared serviceable
Location of air filters: Hall ceiling off great room, ceiling of master bedroom
17)   Filters should be checked monthly and maintained as necessary in the future.
 
Cooling / Heat Pump Return to table of contents
Limitations: The following items are not included in this inspection: humidifiers, dehumidifiers, electronic air filters; thermostat or temperature control accuracy and timed functions; cooling components concealed within the building structure or in inaccessible areas; underground utilities and systems; safety devices and controls (due to automatic operation). Any comments made regarding these items are as a courtesy only. Note that the inspector does not provide an estimate of remaining life on cooling system components, does not determine if cooling systems are appropriately sized, and does not test coolant pressure. Condensation pans and drain lines may clog or leak at any time and should be monitored while in operation in the future.
Condition of cooling system and/or heat pump: Required repair, replacement and/or evaluation (see comments below)
Location: Building exterior, at SW corner
Type: Heat pump
Estimated age: 4 years
Manufacturer: Carrier
Model: 38BRC060360, ser# 2905E27535
Condition of distribution system: See heating
Condition of controls: Appeared serviceable
18)   The pad for the AC condenser was not level. This unit requires adequate support. The compressor may be damaged if this unit is tilted ten or more degrees. The pad should elevate the unit above the soil to prevent corrosion too. A qualified contractor should evaluate and repair as necessary.
 
Fireplaces / Stoves / Chimneys Return to table of contents
Limitations: The following items are not included in this inspection: coal stoves, gas logs, chimney flues (except where visible). Any comments made regarding these items are as a courtesy only. Note that the inspector does not determine the adequacy of drafting or sizing in fireplace and stove flues, nor determine if prefabricated or zero clearance fireplaces are installed in accordance with the manufacturer's specifications. The inspector does not perform any evaluations that require a pilot light to be lit.
Condition of fireplaces, stoves: Appeared serviceable
Location #A: Great room
Fireplace type: Prefabricated
Fuel type: Natural gas
Condition of chimneys: Appeared serviceable
Chimney type: Metal
19)   No blower was visible in the gas fireplace at location #A. The client may want to consider installing a blower for better energy efficiency.
 
Kitchen Return to table of contents
Limitations: The following items are not included in this inspection: free-standing or portable appliances such as dishwashers, trash compactors, refrigerators, freezers, ice makers; specialty appliances such as hot water dispensers, water filters and trash compactors; appliance timers, clocks, cook functions, self and/or continuous cleaning operations, thermostat or temperature control accuracy, and lights. Any comments made regarding these items are as a courtesy only. Note that the inspector does not provide an estimate of the remaining life of appliances, and does not determine the adequacy of operation of appliances such as dishwashers, garbage disposals, trash compactors, ovens, broilers, etc.
Condition of counters: Appeared serviceable
Condition of cabinets: Appeared serviceable
Condition of sinks and related plumbing: Appeared serviceable
Condition of garbage disposal: Appeared serviceable
Condition of dishwasher: Appeared serviceable
Condition of range, cooktop: Appeared serviceable
Range, cooktop type: Natural gas
Condition of refrigerator: N/A
Condition of built-in microwave: Appeared serviceable
20)   The following appliances were not fully evaluated because of the following condition(s): water supply turned off. Appliances not fully evaluated: dishwasher, garbage disposal, faucets and plumbing.
21)   Some, sinks, cabinets and counters showed minor wear.
 
Bathrooms / Laundry / Sinks Return to table of contents
Limitations: The following items are not included in this inspection: overflow drains for tubs and sinks; bidets, heated towel racks, saunas, steam generators, clothes washers, clothes dryers. Any comments made regarding these items are as a courtesy only. Note that the inspector does not determine the adequacy of washing machine drain lines, washing machine catch pan drain lines, or clothes dryer exhaust ducts. The inspector does not operate water supply or shut-off valves for sinks, toilets, bidets, clothes washers, etc. due to the possibility of valves leaking or breaking when operated. The inspector does not determine if shower pans or tub and shower enclosures are water tight, or determine the completeness or operability of any gas piping to laundry appliances.
Location #A: Off hallway
Location #B: Off great room
Location #C: Off master bedroom
Condition of counters: Appeared serviceable
Condition of cabinets: Required repair, replacement and/or evaluation (see comments below)
Condition of sinks and related plumbing: Required repair, replacement and/or evaluation (see comments below)
Condition of toilets: Appeared serviceable
Condition of bathtubs and related plumbing: Required repair, replacement and/or evaluation (see comments below)
Condition of shower(s) and related plumbing: Required repair, replacement and/or evaluation (see comments below)
Condition of ventilation systems: Appeared serviceable
Condition of laundry facilities: Appeared serviceable
Gas supply for laundry equipment present: Yes
240 volt receptacle for laundry equipment present: Yes
22) Caulk was deteriorated by the floor, wall at the bathtub at location #A, B. A qualified person should repair as necessary.

Photo 21  
Hall bath

Photo 22  
Hall bath

Photo 24  
G/R bath
 

23)   Cabinet surfaces, drawers and/or doors showed minor wear, damage at location #A, B, C.

Photo 3  
G/R bath

Photo 4  
G/R bath

24)   The sink drain stopper mechanism at location #A was inoperable. A qualified person should repair or replace as necessary.

Photo 23  
Hall bath
 

25)   The drain cover for the shower at location #C was loose.
Recommend securing drain cover to prevent articles from entering drain pipes.

Photo 25  
Master bath
 

26)   Stains were found in the shelving or cabinet components below the sink at location #C. Plumbing leaks may have occurred in the past. Recommend consulting with the property owner about this, and if necessary, having a qualified person evaluate and repair.

Photo 26  
Master bath
 

27)   The clothes dryer exhaust duct is routed vertically. This can result in extended drying times, premature failure of the motor, drum rollers and heater. A recommended upgrade would be to have a qualified contractor to reconfigure the clothes dryer exhaust duct so it is routed horizontally, or as close to it as possible.
At the least, the dryer duct should be inspected and cleaned on a semi-annual basis to remove lint build-up.

Photo 1  
 

28)   Due to the following conditions, water service turned off, some items could not be fully evaluated.
Items not fully evaluated: sink, tub faucets; shower head(s), supply valves, toilets and related plumbing.

 
Interior Rooms / Areas Return to table of contents
Limitations: The following items are not included in this inspection: security, intercom and sound systems; communications wiring; central vacuum systems; elevators and stair lifts; sources of obnoxious odors; cosmetic deficiencies due to normal wear and tear in wall, floor and ceiling surfaces and coverings, or in equipment; deficiencies relating to interior decorating; low voltage and gas lighting systems. Any comments made regarding these items are as a courtesy only. Note that the inspector does not evaluate any areas or items which require moving stored items, furnishings, debris, equipment, floor coverings, insulation or similar materials. The inspector does not test for asbestos, lead, radon, mold, hazardous waste, urea formaldehyde urethane, or any other toxic substance. Some items such as window operability are tested on a sampled basis. The client should be aware that paint may obscure wall and ceiling defects, floor coverings may obscure floor defects, and furnishings may obscure wall, floor and floor covering defects. If furnishings were present during the inspection, recommend a full evaluation of walls, floors and ceilings that were previously obscured when possible. Determining the cause of odors is not within the scope of this inspection.
Exterior door material: Fiberglass or vinyl, Sliding glass
Condition of exterior entry doors: Appeared serviceable
Condition of interior doors: Required repair, replacement and/or evaluation (see comments below)
Type of windows: Vinyl
Condition of windows: Appeared serviceable
Wall type or covering: Drywall
Condition of walls: Appeared serviceable
Ceiling type or covering: Drywall
Condition of ceilings: Appeared serviceable
Flooring type or covering: Carpet, Vinyl, Tile
Condition of flooring: Required repairs, replacement and/or evaluation (see comments below)
29)   Floor guides are missing at some sliding closet doors.

Photo 14  
South central bedroom

Photo 15  
SW bedroom

30)   Fixtures such as door stops were missing in one or more areas. A qualified person should install missing fixtures as per standard building practices.
31)   Carpeting in one or more areas was significantly stained or soiled. Recommend having carpeting professionally cleaned as necessary.

Photo 27  
Master bedroom

Photo 28  
Great room

32)   Screens in some windows show minor deterioration. A qualified person should evaluate and repair or replace as necessary.
33)   Minor cracks and/or holes were found in walls and ceilings in one or more areas. They do not appear to be a structural concern, but the client may wish to repair these for aesthetic reasons.
 
This report is the exclusive property of this inspection company and the client(s) listed in the report title. Use of this report by any unauthorized persons is prohibited.Look First Inspections requires an inspection agreement to be signed by Client prior to performing an inspection. If you were not present at the inspection and did not sign the Inspection Agreement you, by accepting, paying for, and/or using the inspection report you acknowledge and agree to be bound by the terms and conditions of the inspection agreement and further agree that the Inspection Agreement will form part of the inspection report.