Inspector: Steven Waterman

 

DeRose/Gardella Inspection
Client(s): Jason DeRose
Property address: 734 Gardella Ave.
Oroville, Ca.
Inspection date: Friday, April 21, 2006
This report published on 7/24/2006 8:01:09 AM PDT

View summary page

NOTE:

The findings and recommendations contained in this report are based on the newest and most up to date construction and safety standards in the industry. Some deficiencies may not have been recognized as such at the time the structure was built or remodeled. Other deficiencies are aimed at energy efficiency or air quality, and are not required building restrictions or practices. Look First Inspections is not a specialist in code compliance or zoning restrictions, and no part of the report should be considered as required repair and/or replacement.


How to Read this Report
This report is organized by the property's functional areas. Within each functional area, descriptive information is listed first and shown in bold type. Items of concern follow descriptive information and are shown as follows:
SafetyPoses a risk of injury or death 
Repair/ReplaceRecommend repairing or replacing 
Repair/MaintainRecommend repair and/or maintenance 
Minor defectCorrection likely involves only a minor expense 
MaintainRecommend ongoing maintenance 
EvaluateRecommend evaluation by a specialist 
MonitorRecommend monitoring in the future 
CommentFor your information 
Concern items are sorted by the types listed above.  Click here for a glossary of building construction terms.  Contact your inspector if there are terms that you do not understand, or visit the glossary of construction terms at http://www.reporthost.com/glossary.asp

Table of Contents
General information
Exterior
Roof
Attic
Electric service
Water heater
Heating and cooling
Plumbing and laundry
Kitchen
Bathrooms
Interior rooms


General information Return to table of contents  
Report number: 1032
Type of building: Triplex
Age of building: 43 years, built 1963
Time started: 2:30 p.m.
Time finished: 5:30 p.m.
Present during inspection: Client(s), Tenant(s), Realtor(s)
Occupied: Yes
Weather conditions: Partly cloudy
Temperature: Warm
Ground condition: Dry
Front of structure faces: North
Main entrance faces: North
Foundation type: Slab on grade
The following items are excluded from this inspection: Irrigation system
1) This property has one or more fuel burning appliances, and no carbon monoxide alarms are visible. This is a safety hazard. Recommend installing one or more carbon monoxide alarms as necessary and as per the manufacturer's instructions. For more information, visit http://www.cpsc.gov/CPSCPUB/PREREL/prhtml05/05017.html
2) Structures built prior to 1979 may contain lead-based paint and/or asbestos in various building materials such as insulation, siding, and/or floor and ceiling tiles. Both lead and asbestos are known health hazards. Evaluating for the presence of lead and/or asbestos is not included in this inspection. The client(s) should consult with specialists as necessary, such as industrial hygenists, professional labs and/or abatement contractors for this type of evaluation. For information on lead, asbestos and other hazardous materials in homes, visit these websites:
  • The Environmental Protection Association (http://www.epa.gov)
  • The Consumer Products Safety Commission (http://www.cpsc.gov)
  • The Center for Disease Control (http://www.cdc.gov)
  • 3) Some wall, floor and/or ceiling surfaces were obscured by furniture and/or stored items. Some areas couldn't be evaluated.
     
    Exterior Return to table of contents  
    Footing material: Not visible
    Foundation material: Poured in place concrete
    Apparent wall structure: Wood frame
    Wall covering: Stucco
    Driveway material: Asphalt
    Sidewalk material: Poured in place concrete
    Exterior door material: Solid core wood
    4) Wire splices are exposed due to not being contained in a covered junction box. This is a safety hazard due to the risk of shock and fire. A qualified electrician should evaluate and make repairs as necessary. For example, install securely mounted junction boxes with cover plates where needed to contain wiring splices.

    Photo 59  
    Unit C, evaporative cooler

    Photo 60  
    Unit C, evaporative cooler
    5) The patio covering of Unit B is deteriorated and failing, and has been repaired in the past in a substandard manor. Recommend a qualified contractor be contacted to evaluate and repair as necessary.

    Photo 46  
    Unit B

    Photo 64  
    Unit B
    6) One or more outside faucets are missing backflow prevention devices. These devices reduce the likelihood of polluted or contaminated water entering the potable water supply. This condition can occur when an outside faucet is left in the "on" position with a hose connected and the sprayer head turned off. When pressure in the system fluctuates, water can be drawn back into the water supply pipes from the house. If a chemical sprayer is being used with the hose, those chemicals can enter the water supply pipes.

    Recommend installing backflow prevention devices on all exterior hose bibs where missing. They are available at most home improvement stores and are easily installed. For more information, visit: http://edis.ifas.ufl.edu/BODY_AE079
    7) Fences and/or gates are damaged and/or deteriorated in some areas. A qualified contractor should evaluate and make repairs or replace sections as necessary.

    Photo 47  
    Unit A
     
    8) Gutters in one or more areas are significantly rusted or corroded. Leaks may result. A qualified contractor should evaluate and replace gutters where necessary.

    Photo 65  

    Photo 66  
    9) Siding is damaged and/or deteriorated in one or more areas. A qualified contractor should evaluate and make repairs and/or replace siding as necessary to prevent water and vermin intrusion.

    Photo 3  
    NE corner

    Photo 40  
    West side
    10) Roof decking boards are damaged or deteriorated in one or more areas. A qualified contractor should evaluate and make repairs as necessary.

    Photo 48  
    Unit A
     
    11) One or more downspouts have no extensions, or have extensions that are ineffective. This can result in water accumulating around the structure's foundation, or in basements and crawl spaces if they exist. Accumulated water is a conducive condition to wood destroying insects and organisms, and may also cause the foundation to settle and possibly fail over time. Repairs should be made as necessary, such as installing or repositioning splash blocks, or installing and/or repairing tie-ins to underground drain lines, so rain water is carried at least several feet away from the structure to soil that slopes down and away from the structure.

    Photo 34  
    NE corner

    Photo 38  
    NW corner

    Photo 42  
    SW corner
     
    12) One or more downspouts are dented, damaged and/or crushed. This can restrict the water flow and result in clogging and overflowing gutters. Water may accumulate around the structure's foundation, or in basements and crawl spaces if they exist. Accumulated water is a conducive condition to wood destroying insects and organisms, and may also cause the foundation to settle and possibly fail over time. Damaged downspouts should be repaired or replaced as necessary, and by a qualified contractor if necessary.

    Photo 41  
    SW corner
     
    13) One or more outside faucets are missing handles. Recommend installing handles where missing.

    Photo 33  
    East side

    Photo 37  
    North side

    Photo 39  
    West side
     
    14) One or more exhaust duct end caps are missing. Their purpose is to prevent unconditioned air from entering the house, and keep out birds, rodents and insects. Blocked ducts can cause fan motors and/or clothes dryers to overheat and may pose a fire hazard. Vent cap(s) should be installed where necessary.

    Photo 43  
    Unit A

    Photo 45  
    Unit C
    15) Vegetation such as trees, shrubs and/or vines are in contact with or less than one foot from the structure's exterior. Vegetation can serve as a conduit for wood destroying insects and may retain moisture against the exterior after it rains. Vegetation should be pruned and/or removed as necessary to maintain a one foot clearance between it and the structure's exterior.
    16) Water supply pipes are routed outside and are subject to freezing. Recommend installing pipe wrap or insulated sleeves which are inexpensive and easily installed.
    17) Plumbing clean-out cap is missing. Recommend replacing missing cap.

    Photo 44  
    Unit A
     
    18) Trees and/or shrubs are in contact with or are close to the roof edge(s) in one or more areas. Damage to the roof may result, especially during high winds. Vegetation can also act as a conduit for wood destroying insects. Vegetation should be pruned back and/or removed as necessary to prevent damage and infestation by wood destroying insects.

    Photo 2  
    East side

    Photo 62  

    Photo 99  

    Photo 101  
    19) The exterior finish in some areas is failing. A qualified contractor should prep (pressure wash, scrape, sand, prime caulk, etc.) and repaint or restain areas as needed and as per standard building practices.

    Photo 35  

    Photo 36  
    20) One or more sections of foundation and/or exterior walls are excluded from this inspection due to lack of access from vegetation, debris and/or stored items.
    21) Minor cracks were found in the driveway. However they don't appear to be a structural concern and no trip hazards were found. No immediate action is recommended, but the client(s) may wish to have repairs made or have cracked sections replaced for aesthetic reasons.
    22) Minor cracks were found in one or more sidewalk or patio sections. However they don't appear to be a structural concern and no trip hazards were found. No immediate action is recommended, but the client(s) may wish to have repairs made or have cracked sections replaced for aesthetic reasons.
    23) The substructure of the deck is excluded from the inspection due to limited access because of the low height. (Unit B)
     
    Roof Return to table of contents  
    Roof inspection method: Traversed
    Roof type: Gable
    Roof covering: Asphalt or fiberglass composition shingles
    Estimated age of roof: More than 10 years
    Gutter & downspout material: Steel
    Roof ventilation: Adequate
    24) Old evaporative cooler has been left on the roof. High wind could possibly cause it to fall, creating a serious safety hazard. Recommend removing and disposing of old cooler.

    Photo 61  
    Unit C
     
    25) One or more sections of roof flashing are deteriorated and/or rusted. This has occurred at all three evaporative coolers. Leaks have occurred as a result. A qualified roofing contractor should evaluate and replace flashing where necessary.

    Photo 52  
    Unit A

    Photo 54  
    Unit B

    Photo 58  
    Unit C

    Photo 76  
    Unit A

    Photo 86  
    Unit B

    Photo 93  
    Unit C
    26) One or more composition shingles are damaged, deteriorated and/or missing, and should be replaced. Leaks may occur as a result. A qualified roofing contractor should evaluate and make repairs as necessary.

    Photo 49  
    East peak

    Photo 63  

    Photo 67  
    SW corner

    Photo 68  
    SW corner
    27) One or more "rubber boot" flashings are damaged or deteriorated, most are missing completely and may result in leaks or vermin intrusion. A qualified contractor should replace flashings where necessary.

    Photo 69  

    Photo 70  

    Photo 71  

    Photo 72  
    28) Water supply line for the evaporative cooler on Unit A runs up through the water heater flue. This can cause failure of the supply lines resulting in damage to the water heater or possible water damage to the living spaces below. Recommend contacting a qualified contractor to reroute the supply line.

    Photo 51  
    Unit A
     
    29) Weather cap for the water heater flue for unit B is missing. This can allow water to enter the combustion chamber of the water heater resulting in premature failure. Recommend replacing weather cap.

    Photo 56  
    Unit B
     
    30) The sealant around the water supply line for the evaporative cooler for unit B has failed. Recommend resealing.

    Photo 55  
    Unit B
     
    31) Debris has accumulated in one or more gutters. This is a conducive condition for wood destroying insects since gutters may overflow and cause water to come in contact with the structure's exterior or make water accumulate around the foundation. Gutters should be cleaned now and as necessary in the future.

    Photo 102  
     
    32) Trees and/or shrubs are in contact with or are close to the roof edge(s) in one or more areas. Damage to the roof may result, especially during high winds. Vegetation can also act as a conduit for wood destroying insects. Vegetation should be pruned back and/or removed as necessary to prevent damage and infestation by wood destroying insects.

    Photo 103  
     
     
    Attic Return to table of contents  
    Inspection method: Traversed
    Roof structure type: Trusses
    Ceiling structure: Ceiling beams
    Insulation material: Mineral wool loose fill
    Insulation depth: approx. 4
    33) One or more sections of wiring that weren't terminated were found. This is a potential safety hazard due to the risk of shock. A qualified electrician should evaluate and repair as necessary. For example, cutting the wire to length and terminating the wire with wire nuts in a securely anchored, covered, properly sized junction box.

    Photo 98  
    Unit C
     
    34) Wire splices are exposed due to not being contained in a covered junction box. This is a safety hazard due to the risk of shock and fire. A qualified electrician should evaluate and make repairs as necessary. For example, install securely mounted junction boxes with cover plates where needed to contain wiring splices.

    Photo 81  
    Unit A

    Photo 97  
    Unit C
    35) Some wiring is loose, unsupported, or inadequately supported. Standard building practices require non-metallic sheathed wiring to be trimmed to length, attached to runners or to solid backing with fasteners at intervals of 4-1/2 ft. or less. Fasteners should be installed within 12 inches of all enclosures. A qualified, licensed electrician should evaluate and repair as necessary. For example, trim wire to length and/or install staples as needed.

    Photo 77  
    Unit A

    Photo 78  

    Photo 79  

    Photo 87  
    Unit B
    36) Plywood decking material splintered. Structural integrity of the roof is compromised. Someone walking on the roof in that area has the potential to fall through. Recommend contacting a qualified roofing contractor to evaluate and repair as necessary.

    Photo 82  
    Unit A
     
    37) Cover plate(s) are missing from one or more electric boxes, such as for receptacles, switches and/or junction boxes. They are intended to contain fire and prevent electric shock from exposed wires. This is a safety hazard due to the risk of fire and shock. Cover plates should be installed where missing.

    Photo 73  
    Unit A

    Photo 75  
    Unit A

    Photo 80  

    Photo 85  
    Unit B
    38) One or more areas of the roof structure were wet or had elevated levels of moisture at the time of the inspection. There appears to be an active leak in the roof or structure exterior. A qualified contractor should evaluate and repair as necessary.

    Photo 74  
    Unit A

    Photo 83  
    Unit A

    Photo 84  
    Unit B

    Photo 88  
    Unit B

    Photo 89  
    Unit B

    Photo 90  
    Unit B

    Photo 91  

    Photo 94  
    Unit C

    Photo 95  
    Unit C

    Photo 96  
    Unit C
    39) No insulation is installed over the attic access hatch. Recommend installing insulation above hatch for better energy efficiency.
    40) Attic access hatch missing for unit B. Recommend replacing with a piece of lumber cut to fit size of access opening.

    Photo 12  
    Unit B
     
    41) The attic exhaust fan(s) were inoperable during the inspection. Recommend consulting with the property owner(s) as to how it operates and/or having a qualified contractor evaluate and repair if necessary.
    42) Water supply pipes are uninsulated. Recommend insulating pipes as necessary for better energy efficiency and to prevent water pipes from freezing.
     
    Electric service Return to table of contents  
    Primary service type: Overhead
    Primary service overload protection type: Circuit breakers
    Service amperage (amps): 100 for each unit
    Service voltage (volts): 120/240
    Location of main service switch: SE corner of structure
    Location of sub panels: Units A & C in hallway, Unit B in dining area.
    Service entrance conductor material: Aluminum
    Main disconnect rating (amps): Not applicable, no single main disconnect
    Branch circuit wiring type: Non-metallic sheathed
    Solid strand aluminum branch circuit wiring present: No
    Smoke detectors present: No
    43) The service drop wires are in contact with trees or vegetation. Recommend having a qualified tree service company or arborist prune or remove trees as necessary to prevent straining or abrading the service drop wires.

    Photo 100  
     
     
    Water heater Return to table of contents  
    Estimated age: Unit A 5 yrs, Unit B 14 yrs, Unit C 11 yrs
    Type: Tank
    Energy source: Natural gas
    Capacity (in gallons): 30
    Manufacturer: American, Rheem Jetglass
    44) The temperature-pressure relief valve drain lines for all three water heaters is routed upwards. This drain line should be routed either down or horizontally. This is a safety hazard as water may not be able to flow through the drain line adequately when the valve releases due to accumulated water. Also, accumulated water may corrode the valve and prevent it from working. A qualified plumber should evaluate and repair so the drain line is routed down or horizontally, but not up. For more information, visit Water Heater Rescue - Down and Out

    Photo 6  
    Unit B

    Photo 19  
    Unit A
    45) Based on the location of the water heater and the visible venting, the water heater may have an inadequate source of combustion and/or dilution air. All gas appliances require adequate air (approximately 50 cubic feet per 1000 BTU) for combustion, dilution and ventilation. This is a potential safety hazard, and may result in combustion fumes entering living spaces. A qualified contractor should evaluate and make repairs as necessary, such as installing exterior vents, or grills in walls or doors.

    Photo 21  
    Unit A
     
    46) The water heaters do not have seismic straps or struts installed. This is a potential safety hazard since movement can cause leaks in the gas supply lines or damage wiring. Leaks may also occur in water supply pipes. A qualified contractor should install seismic straps or struts as necessary and as per standard building practices.
    47) Gas shut-off valve handle missing. Recommend replacing handle.

    Photo 18  
    Unit A
     
    48) Corrosion was found in one or more areas on the water heater. The water heater may be failing. A qualified plumbing contractor should evaluate and replace or repair water heater if necessary.

    Photo 32  
    Unit C
     
    49) Water stains were found below the water heater in Unit C. This may be a sign that the water heater is failing. A qualified plumbing contractor should evaluate and replace or repair the water heater if necessary.
    50) The estimated useful life for most water heaters is 8 to 12 years. The inspector was unable to determine the age of the water heater in Unit B due to the manufacturer's label being obscured, no serial number being visible, or the serial number not clearly indicating the age. The clients should be aware that this water heater may be near, at, or beyond its useful life and may need replacing at any time. Recommend attempting to determine the water heater's age, and budgeting for a replacement if necessary.
    51) The estimated useful life for most water heaters is 8 to 12 years. The water heater in Unit C appears to be at this age or older and may need replacing at any time. Recommend budgeting for a replacement in the near future.
     
    Heating and cooling Return to table of contents  
    Primary heating system energy source: Natural gas
    Primary heat system type: Natural gas wall units
    Primary A/C energy source: Electric
    Primary Air conditioning type: Evaporative cooler
    Distribution system: Sheet metal ducts
    52) Because of the age and/or condition of these furnace(s), recommend that a qualified heating and cooling technician inspect the heat exchanger and perform a Carbon Monoxide test when it's serviced.
    53) One or more air supply ducts are broken or disconnected. Increased moisture levels in unconditioned spaces and higher energy costs may result. A qualified contractor should evaluate and make permanent repairs as necessary.

    Photo 92  
    Unit C
     
    54) The evaporative cooler in unit C was inoperable at the time of this inspection. Recommend contacting a qualified HVAC company to evaluate and repair as necessary.
    55) The evaporative coolers on the roof have evidence of corrosion. Due to their apparent age recommend evaluation and inspection by a qualified HVAC company.

    Photo 50  
    Unit A

    Photo 53  
    Unit B

    Photo 57  
    Unit C
     
     
    Plumbing and laundry Return to table of contents  
    Location of main water meter: By street
    Location of main fuel shut-off: SE corner
    Water service: Public
    Service pipe material: Galvanized steel
    Supply pipe material: Copper
    Vent pipe material: Plastic
    Drain pipe material: Plastic
    Waste pipe material: Not visible
    56) No clothes dryer exhaust duct is installed in Unit B. Clothes dryers produce large amounts of moisture which should not enter structure interiors. Damage to building components may result. A rigid or semi-rigid metal exhaust duct should be installed as per standard building practices, and by a qualified contractor if necessary. For information, visit http://www.cpsc.gov/CPSCPUB/PUBS/5022.html
    57) Neither the clothes washer nor dryer were operated or evaluated. They are excluded from this inspection.
     
    Kitchen Return to table of contents  
    58) One or more cabinets are not securely fastened to the wall. This is a safety hazard due to the risk of the cabinet(s) falling. A qualified contractor should evaluate and repair as necessary.

    Photo 11  
    Unit B
     
    59) Cover plate(s) are missing from one or more electric boxes, such as for receptacles, switches and/or junction boxes. They are intended to contain fire and prevent electric shock from exposed wires. This is a safety hazard due to the risk of fire and shock. Cover plates should be installed where missing.

    Photo 17  
    Unit A
     
    60) One or more electric receptacles that serve countertop surfaces within six feet of a sink appear to have no ground fault circuit interrupter (GFCI) protection. This is a safety hazard due to the risk of shock. A qualified electrician should evaluate to determine if GFCI protection exists, and if not, repairs should be made so that all receptacles that serve countertop surfaces within six feet of sinks have GFCI protection. For example, install GFCI receptacles or circuit breaker(s) as needed.

    Photo 4  
    Unit B

    Photo 13  
    Unit A
    61) No "air gap" is installed for the dishwasher drain line. Air gaps are a device meant to prevent water from the sink drain or food disposal from entering the dishwasher. These are required in some municipalities for new construction and when remodeling. The client(s) should consult with a qualified contractor to determine if an air gap should be installed.

    Photo 15  
    Unit A
     
    62) The range hood fan is inoperable in Unit B. A qualified contractor should evaluate and repair or replace the fan or the range hood as necessary.
    63) Vinyl flooring in one or more "wet" areas is damaged and/or deteriorated. The wooden subfloor below may be damaged by water intrusion. A qualified contractor should evaluate and replace or repair the damaged flooring.
    64) One or more filters are missing from the range hood exhaust system. Filters should be replaced as necessary.
    65) One or more handles are missing from water shut-off valves. Handles should be replaced where missing.

    Photo 16  
    Unit A
     
    66) One or more sink drains use flexible drain pipe. This type of drain pipe is more likely to clog than smooth wall pipe. Recommend having a qualified plumber replace this pipe with standard plumbing components (smooth wall pipe) to prevent clogged drains.

    Photo 5  
    Unit B
     
    67) Shelving or other components are missing from one or more cabinets. Missing shelving and/or components should be replaced, and by a qualified contractor if necessary.
    68) The oven light is inoperable. Recommend replacing bulb or having repairs made if necessary by a qualified appliance technician.
    69) One or more light fixtures appear to be inoperable. Recommend further evaluation by replacing bulb(s) and/or consulting with the property owner(s). Repairs or replacement of the light fixture(s) by a qualified electrician may be necessary.
    70) The enamel coating on one or more sinks is damaged and/or deteriorated. For example, chipped or worn, and/or rust on some exposed steel. However, no leaks were found due to the deterioration. The client(s) should evaluate to determine if the sinks should be replaced.
    71) Minor damage and/or deterioration was found at countertops in one or more areas. The client(s) should evaluate and consider having repairs made, and/or countertops replaced where necessary.
    72) Water stains and/or minor water damage was found in the shelving or cabinet components below the sink. The client(s) should evaluate and consider having repairs made.
     
    Bathrooms Return to table of contents  
    73) One or more electric receptacles that serve countertop surfaces within six feet of a sink appear to have no ground fault circuit interrupter (GFCI) protection. This is a safety hazard due to the risk of shock. A qualified electrician should evaluate to determine if GFCI protection exists, and if not, repairs should be made so that all receptacles that serve countertop surfaces within six feet of sinks have GFCI protection. For example, install GFCI receptacles or circuit breaker(s) as needed.

    Photo 7  
    Unit B

    Photo 26  
    Unit A
    74) Floor tiles installed in "wet" areas have gaps between them. A qualified contractor should evaluate, make repairs if necessary, and replace flooring with a waterproof floor such as sheet vinyl in wet areas.
    75) One or more bathrooms with a shower do not have an exhaust fan installed. Moisture accumulation will occur and may damage the structure. Even if the bathroom has a window that opens, it likely does not provide adequate ventilation, especially during cold weather when the window is closed. A qualified contractor should install exhaust fans as per standard building practices where missing in bathrooms with showers.
    76) Water damage was found in the shelving or cabinet components below one or more sinks. A qualified contractor should evaluate and make repairs as necessary.

    Photo 30  
    Unit C

    Photo 31  
    Unit C
    77) Hole in tub tile. This can allow water penetration into wall void. Recommend sealing hole.

    Photo 23  
    Unit A
     
    78) Caulk is missing or deteriorated above one or more bathtubs, where the tub surround meets the tub. It should be replaced where deteriorated and/or applied where missing to prevent water intrusion and damage to the wall structure.

    Photo 9  
    Unit B

    Photo 24  
    Unit A
    79) Tub overflow covers missing. Recommend replacing covers.

    Photo 10  
    Unit B

    Photo 22  
    Unit A
    80) The enamel coating on one or more sinks is damaged and/or deteriorated. For example, chipped or worn, and/or rust on some exposed steel. However, no leaks were found due to the deterioration. The client(s) should evaluate to determine if the sinks should be replaced.

    Photo 8  
    Unit B
     
    81) The enamel coating on one or more bathtubs is damaged and/or deteriorated. For example, chipped or worn, and/or rust on some exposed steel. However, no leaks were found due to the deterioration. The client(s) should evaluate to determine if the bathtub(s) should be replaced.
     
    Interior rooms Return to table of contents  
    82) One or more open ground, three-pronged electric receptacles were found. This is a safety hazard due to the risk of shock. A qualified electrician should evaluate and make repairs as necessary. For example, replacing receptacles or correcting wiring circuits.

    Grounding type receptacles began being required in residential structures during the 1960s. Based on the age of this structure and the presence of 2-pronged receptacles in some areas of this structure, an acceptable repair may be to simply replace the ungrounded 3-pronged receptacles with 2-pronged receptacles. However the following appliances require grounding type receptacles:

  • Computer hardware
  • Refrigerators
  • Freezers
  • Air conditioners
  • Clothes washers
  • Clothes dryers
  • Dishwashers
  • Kitchen food waste disposers
  • Information technology equipment
  • Sump pumps
  • Electrical aquarium equipment
  • Hand-held motor-operated tools
  • Stationary and fixed motor-operated tools
  • Light industrial motor-operated tools
  • Hedge clippers
  • Lawn mowers

    This list is not exhaustive. Grounded circuits and receptacles should be installed in locations where such appliances will be used.
  • 83) Two-pronged electric receptacles rather than three-pronged, grounded receptacles are installed in one or more interior rooms. They are considered to be unsafe by today's standards and limit the ability to use appliances that require a ground in these rooms. Examples of appliances that require grounded receptacles include:

  • Computer hardware
  • Refrigerators
  • Freezers
  • Air conditioners
  • Clothes washers
  • Clothes dryers
  • Dishwashers
  • Kitchen food waste disposers
  • Information technology equipment
  • Sump pumps
  • Electrical aquarium equipment
  • Hand-held motor-operated tools
  • Stationary and fixed motor-operated tools
  • Light industrial motor-operated tools
  • Hedge clippers
  • Lawn mowers

    This list is not exhaustive. A qualified electrian should evaluate and install grounded receptacles as per the client(s)' needs and standard building practices.
  • 84) No smoke alarms are visible. This is a safety hazard. A qualified electrician should install smoke alarms as per standard building practices (functioning one exists in hallways leading to bedrooms, and in each bedroom, etc.). For more information, visit http://www.cpsc.gov/cpscpub/pubs/5077.html
    85) Stains and elevated levels of moisture were found in one or more ceiling areas. The stain(s) appear to be due to roof leaks. A qualified contractor should evaluate and repair as necessary.

    Photo 20  
    Unit A
     
    86) Screen(s) in one or more windows are missing. The client(s) should ask the property owner(s) about this. Screens are often removed for window cleaning and they may be stored somewhere. If not, then recommend installing screens where missing.
    87) One or more air supply registers are loose or installed in a substandard way. Repairs should be made as necessary so registers are securely attached, flush with the surface they are installed on, and otherwise correctly installed.

    Photo 14  
    Unit A
     
    88) Screen(s) in one or more windows are torn or have holes in them. Screens should be replaced where necessary.
    89) One or more interior doors are damaged and/or deteriorated and should be repaired or replaced by a qualified contractor.

    Photo 27  
    Unit A
     
    90) The weatherstrip around one or more exterior entry doors is missing and/or deteriorated. Weatherstrip should be installed where missing and/or replaced where deteriorated, and by a qualified contractor if necessary.
    91) Carpeting in one or more rooms is damaged and/or significantly deteriorated. Recommend replacing carpeting where necessary.

    Photo 28  
    Unit A

    Photo 29  
    Unit A
    92) Fixtures such as door stops, towel bars and/or toilet paper holders are missing in one or more areas. Recommend having a qualified contractor install fixtures where missing.
    93) Carpeting in one or more rooms is soiled and/or stained. Recommend having carpeting professionally cleaned as necessary.
    94) Minor cracks were found in ceilings in one or more areas. They do not appear to be a structural concern, but the client(s) may wish to repair these for aesthetic reasons.
    95) Minor cracks and holes were found in walls in one or more areas. They do not appear to be a structural concern, but the client(s) may wish to repair these for aesthetic reasons.

    Photo 25  
    Unit A
     
     
    This report is the exclusive property of this inspection company and the client(s) listed in the report title. Use of this report by any unauthorized persons is prohibited.Look First Inspections requires an inspection agreement to be signed by Client prior to performing an inspection. If you were not present at the inspection and did not sign the Inspection Agreement you, by accepting, paying for, and/or using the inspection report you acknowledge and agree to be bound by the terms and conditions of the inspection agreement and further agree that the Inspection Agreement will form part of the inspection report.