Lazer Construction

Website: http://www.LAZERswfl.com
Email: chrisalley@lazerswfl.com
Phone: (239) 793-6800 · (239) 289-1994
FAX: (866) 923-0703
1988 Sagebrush Circle 
Naples, FL 34120
Inspector: Chris Alley
CBC1250945

Property Inspection Report
Client(s): Gomez
Property address: 123 1st Street
Naples, FL 34111
Inspection date: Friday, May 01, 2009
This report published on 5/4/2009 10:08:28 AM CDT

View summary page

This report is the exclusive property of this inspection company and the client(s) listed in the report title. Use of this report by any unauthorized persons is prohibited.

 
How to Read this Report
This report is organized by the property's functional areas.  Within each functional area, descriptive information is listed first and is shown in bold type.  Items of concern follow descriptive information. Concerns are shown and sorted according to these types:
SafetyPoses a risk of injury or death 
Major DefectCorrection likely involves a significant expense 
Repair/ReplaceRecommend repairing or replacing 
Repair/MaintainRecommend repair and/or maintenance 
Minor DefectCorrection likely involves only a minor expense 
MaintainRecommend ongoing maintenance 
EvaluateRecommend evaluation by a specialist 
MonitorRecommend monitoring in the future 
CommentFor your information 

Click here for a glossary of building construction terms.  Contact your inspector if there are terms that you do not understand, or visit the glossary of construction terms at http://www.reporthost.com/glossary.asp

Table of Contents
Exterior
Roof
Garage
Attic
Electric service
Water heater
Heating and cooling
Plumbing and laundry
Well
Kitchen
Bathrooms
Interior rooms
General information
 
Exterior Return to table of contents
Footing material: Poured in place concrete
Foundation material: Poured in place concrete
Apparent wall structure: Concrete block
Wall covering: Stucco
Driveway material: Poured in place concrete
Sidewalk material: Poured in place concrete
Exterior door material: Solid core steel
1) Garage to Room conversion. Garage door and track are still intacked. No permit was found for conversion. May have to be restored to original condition. Check with county records.
Cost estimate: $ 1,500

Photo 2  
Garage to room conversion. No permit on record.

Photo 8  
Inside of garage ro room conversion. Garage door is still there.

2) Lania to Room conversion. No permit was found for conversion. May have to be restored to original condition. Check with county records.
Cost estimate: $ 500

3) One or more light fixtures located in "wet" or "damp" locations have no visible rating for use in wet locations. This is a safety hazard due to the risk of shock. A qualified electrician should evaluate and replace light fixtures as necessary and as per standard building practices.
Cost estimate: $ 150

Photo 6  
Improper wiring of exterior light.
 

4) Fascia boards are damaged or deteriorated in one or more areas. A qualified contractor should evaluate and make repairs as necessary.

Photo 3  
Many rotten wood areas arround home 1 of 6 (others not shown, but similar in nature)
 

5) One or more outside faucets appeared to be inoperable. No water came out of the faucet(s) when turned on. Standards of Practice, the inspector did not attempt to turn on or off any water supply shut-off valves. Recommend that the client(s) ask the seller about outside faucets with no water, and/or have a qualified plumber evaluate and repair faucet(s) as necessary.
6) One or more downspouts have no extensions, or have extensions that are ineffective. This can result in water accumulating around the structure's foundation, or in basements and crawl spaces if they exist. Accumulated water is a conducive condition to wood destroying insects and organisms, and may also cause the foundation to settle and possibly fail over time. Repairs should be made as necessary, such as installing or repositioning splash blocks, or installing and/or repairing tie-ins to underground drain lines, so rain water is carried at least several feet away from the structure to soil that slopes down and away from the structure.
7) One or more soffit vent screens are missing and/or deteriorated. Birds and vermin may enter the attic because of this. Screens should be replaced or repaired where necessary, or installed where missing.

Photo 3  
Many rotten wood areas arround home 1 of 6 (others not shown, but similar in nature)
 

8) Minor cracks were found in the driveway. However they don't appear to be a structural concern and no trip hazards were found. No immediate action is recommended, but the client(s) may wish to have repairs made or have cracked sections replaced for aesthetic reasons.
9) Minor cracks were found in one or more sidewalk or patio sections. However they don't appear to be a structural concern and no trip hazards were found. No immediate action is recommended, but the client(s) may wish to have repairs made or have cracked sections replaced for aesthetic reasons.
10) The exterior finish in some areas is failing. A qualified contractor should prep (pressure wash, scrape, sand, prime caulk, etc.) and repaint or restain areas as needed and as per standard building practices.
 
Roof Return to table of contents
Roof inspection method: Viewed from ground with binoculars
Roof type: Gable
Roof covering: Asphalt or fiberglass composition shingles
Estimated age of roof: 2 years
Gutter & downspout material: Aluminum
Roof ventilation: Adequate
11) Debris has accumulated in one or more gutters. This is a conducive condition for wood destroying insects since gutters may overflow and cause water to come in contact with the structure's exterior or make water accumulate around the foundation. Gutters should be cleaned now and as necessary in the future.
Cost estimate: $ 187

12) Trees are overhanging roof and are within 10 feet of roof vertically. This is a conducive condition for wood destroying insects and organisms since organic debris such as leaves or needles are more likely to accumulate on the roof surface. Accumulated debris may cause water to enter gaps in the roof surface and leak into attic and/or interior spaces. Trees should be pruned so they are at least 10 feet above roof, or don't overhang the roof.
Cost estimate: $ 100

13) Trees and/or shrubs are in contact with or are close to the roof edge(s) in one or more areas. Damage to the roof may result, especially during high winds. Vegetation can also act as a conduit for wood destroying insects. Vegetation should be pruned back and/or removed as necessary to prevent damage and infestation by wood destroying insects.
Cost estimate: $ 100
 
Garage Return to table of contents

14)   Garage was converted into a room. See previous comments.

Photo 8  
Inside of garage ro room conversion. Garage door is still there.
 
 
Attic Return to table of contents
Inspection method: Viewed from hatch, Partially traversed
Roof structure type: Trusses
Ceiling structure: Trusses
Insulation material: Fiberglass roll or batt
15) There is no insulation on the lines to prevent condensation.

Photo 9  
Refrigerant lines are not insulated.
 

16) Air Conditioning supply has been stepped on.

Photo 10  
Air Conditioning supply has been stepped on.
 

17) No weatherstrip is installed around the attic access hatch. Weatherstrip should be installed around the hatch to prevent heated interior air from entering attic.
 
Electric service Return to table of contents
Primary service type: Overhead
Primary service overload protection type: Circuit breakers
Service amperage (amps): 200
Smoke detectors present: Yes
18) Wiring for microwave is incorrect.
Cost estimate: $ 125

Photo 5  
Improper wiring and ventalation of microwave.
 

19) The flood light on the exterior of the home is wired incorrectly. Not per code.
Cost estimate: $ 125
 
Water heater Return to table of contents
Estimated age: 1 year
Type: Tank
Energy source: Electricity
Capacity (in gallons): 40
20) Old vent was left.
Cost estimate: $ 150

Photo 4  
Old vent stack from gas water heater. Gas heater no longer is there.
 
 
Heating and cooling Return to table of contents
Estimated age: 3 years
Primary heating system energy source: Electric
Primary heat system type: Forced air
Primary A/C energy source: Electric
Primary Air conditioning type: Split system
Distribution system: Fiberglass
21) No filter is visible for the heating/cooling system. As a result, unfiltered air will flow through the system, and the heating/cooling equipment life and the indoor air quality may be reduced. Correctly sized filter(s) should be installed. If necessary, guides or retaining devices should be installed or repaired so filter(s) are securely anchored and gaps around edges are minimized.
22) The last service date of this system appears to be more than two years ago, or the inspector was unable to determine the last service date. The client(s) should ask the property owner(s) when it was last serviced. If unable to determine the last service date, or if this system was serviced more than two years ago, a qualified heating and cooling contractor should inspect, clean, and service this system, and make repairs if necessary. This servicing should be performed every few years in the future, or as per the contractor's recommendations.
 
Plumbing and laundry Return to table of contents
Water service: Private
Service pipe material: Not visible
Supply pipe material: CPVC
Vent pipe material: Plastic
Drain pipe material: Plastic
Waste pipe material: Plastic
23) Recommend having the septic tank inspected. Recommend having the tank pumped if it was last pumped more than 3 years ago.
24) Neither the clothes washer nor dryer were operated or evaluated. They are excluded from this inspection.
 
Well Return to table of contents
Location of well equipment: Back of home
Location of tank shut off valve: Same as above
25) Based on information provided to the inspector or evidence found during the inspection, one or more unused or abandoned wells may exist on this property. This is a potential source for contamination of the aquifer. Old casings may deteriorate and rust. Contaminants from sources such as septic fields, surface water, dumps, animals, etc. may flow straight down to the aquifer and then travel on to other portions of the aquifer. The client(s) should consult with a qualified well contractor about decommissioning the unused or abandoned well(s). For more information, visit:
http://www.wellowner.org

26) Cover plate(s) are broken at one or more electric boxes, such as for receptacles, switches and/or junction boxes. They are intended to contain fire and prevent electric shock from exposed wires. This is a safety hazard due to the risk of fire and shock. Cover plates should be replaced where necessary.
27) Recommend having the well water tested for coliform bacteria, nitrates, and anything else of local concern, by a qualified lab. For more information, visit:
http://www.wellowner.org
 
Kitchen Return to table of contents

28) The range can tip forward, and no anti-tip bracket appears to be installed. This is a safety hazard since the range may tip forward when weight is applied to the open door, such as when a small child climbs on it, or if heavy objects are dropped on it. Anti-tip brackets have been sold with all free standing ranges since 1985. An anti-tip bracket should be installed to eliminate this safety hazard. For more information, visit:
http://www.google.com/search?q=range+anti+tip+device

29) The dishwasher appears to be inoperable. The client(s) should ask the property owner(s) about this, and if necessary, the dishwasher should be replaced, or a qualified appliance technician should evaluate and repair.
30) The water supply to the dishwasher appears to be inoperable. The shut-off valve may be turned off. The inspector was unable to fully evaluate the dishwasher and its drain system. The client(s) should ask the property owner(s) about this, and if necessary, a qualified plumber or appliance technician should evaluate and repair.
31) The range hood fan is inoperable. A qualified contractor should evaluate and repair or replace the fan or the range hood as necessary.
32) One or more kitchen appliances appear to be near, at, or beyond their intended service life of 10 to 15 years. Recommend budgeting for replacements as necessary.
 
Bathrooms Return to table of contents

33) One or more toilets have no water supply and could not be fully evaluated. The shut-off valve(s) may be turned off, or repairs may be necessary. The client(s) should ask the property owner(s) about this, and have a qualified plumber evaluate and repair if necessary.
 
Interior rooms Return to table of contents

34) Cover plate(s) are missing from one or more electric boxes, such as for receptacles, switches and/or junction boxes. They are intended to contain fire and prevent electric shock from exposed wires. This is a safety hazard due to the risk of fire and shock. Cover plates should be installed where missing.
35) Batteries in all the smoke alarms should be replaced after taking occupancy, and annually in the future. "Chirping" noises emitted from smoke alarms typically indicate that batteries need replacing. For more information, visit:
http://www.cpsc.gov/cpscpub/pubs/5077.html

36) The doorbell appears to be inoperable. Recommend having a qualified electrician evaluate and repair as necessary.
37) Lock mechanisms on one or more windows are missing and/or damaged so that they are inoperable. Repairs should be made by a qualified contractor or service technician so that windows lock and unlock easily.
38) Screen(s) in one or more windows are torn or have holes in them. Screens should be replaced where necessary.
39) Stains were found in one or more ceiling areas. However, no elevated levels of moisture were found. The stain(s) may be due to past roof and/or plumbing leaks. Recommend asking the property owner(s) about this, and monitoring the stained area(s) in the future, especially after heavy or prolonged rain. If elevated moisture is found in the future, a qualified contractor should evaluate and repair as necessary.
40) Minor cracks were found in ceilings in one or more areas. They do not appear to be a structural concern, but the client(s) may wish to repair these for aesthetic reasons.
41) Minor cracks were found in walls in one or more areas. They do not appear to be a structural concern, but the client(s) may wish to repair these for aesthetic reasons.
 
General information Return to table of contents
Inspector's name: Chris Alley
Type of building: Single family
Present during inspection: Client(s), Realtor(s)
Occupied: No
Weather conditions: Clear
Temperature: Warm
Ground condition: Dry
42)  

Photo 1  
Front of Home
 
 

Photo 7  
Lania converted to a room. No permit records found.
 

 
Your default report footer here...