View as PDF

Patrick Johnson Home Inspections

Website: http://www.reporthost.com/johnsonhome
Company email: patrickj@maine.rr.com
Inspector's email: djohnson9@me.nachi.org
Phone: (207) 776-0680
15 Ritz Farm Rd 
Gorham ME 04038-2296
Inspector: Darren Johnson

Property Inspection Report
Client(s): Robert Bates
Property address: 746 Methodist Rd.
Westbrook, ME. 04092
Inspection date: Friday, February 05, 2010
This report published on 2/6/2010 4:11:24 PM EST

View summary page

This report is the exclusive property of this inspection company and the client(s) listed in the report title. Use of this report by any unauthorized persons is prohibited.

 
How to Read this Report
This report is organized by the property's functional areas.  Within each functional area, descriptive information is listed first and is shown in bold type.  Items of concern follow descriptive information.
Concerns are shown and sorted according to these types:
SafetyPoses a risk of injury or death 
Major DefectCorrection likely involves a significant expense 
Repair/ReplaceRecommend repairing or replacing 
Repair/MaintainRecommend repair and/or maintenance 
Minor DefectCorrection likely involves only a minor expense 
MaintainRecommend ongoing maintenance 
EvaluateRecommend evaluation by a specialist 
MonitorRecommend monitoring in the future 
CommentFor your information 

Click here for a glossary of building construction terms.  Contact your inspector if there are terms that you do not understand, or visit the glossary of construction terms at http://www.reporthost.com/glossary.asp

Table of Contents
General Information
Grounds
Exterior / Foundation
Roof / Attic
Garage / Carport
Electric
Plumbing / Fuel Systems
Water Heater
Heating
Fireplaces / Stoves / Chimneys
Kitchen
Bathrooms / Laundry / Sinks
Interior Rooms / Areas
 
General Information Return to table of contents
Report number: 2
Time started: 12:00 pm
Time finished: 2:30 pm
Inspector: Darren Johnson
Present during inspection: Tenant
Client present for discussion at end of inspection: No
Weather conditions: Clear
Temperature: Cold
Ground condition: Frozen
Inspection fee: Free
Type of building: Single family, Detached garage
Age of building(s): 100 +
Source for building age: Property owner
Front of building faces: East
Main entrance faces: East
Occupied: Yes, Furniture or stored items were present
Property owner's name: Robert Bates
Additions and modifications:
 
Grounds Return to table of contents
Limitations: The following items are not included in this inspection: swimming pools, spas, hot tubs, water features and related equipment; playground, recreation or leisure equipment; landscape lighting; areas below exterior structures with less than three feet of vertical clearance; irrigation systems; invisible fencing; sea walls, docks and boathouses. Any comments made regarding these items are as a courtesy only. Note that the inspector does not test or determine the adequacy of drainage systems for grounds, walkways, below-grade stairs and roof downspouts. The inspector does not provide an evaluation of geological conditions and/or site stability, compliance of pool or spa fencing with municipal requirements, or determination that deck, balcony and/or stair membranes are watertight.
Condition of retaining walls: Appeared serviceable
Retaining wall material: Block
Site profile: Minor slope
Condition of driveway: Appeared serviceable
Driveway material: Asphalt
Condition of sidewalks and/or patios: Appeared serviceable
Sidewalk material: Brick
Condition of deck, patio and/or porch covers: Appeared serviceable
Deck, patio, porch cover material and type: Covered (Refer to Roof section)
Condition of decks, porches and/or balconies: Required repairs, replacement and/or evaluation (see comments below)unable to inspect under front porch due to shrubs and no access.Rear deck not properly fastened to home
Condition of guardrails: Appeared serviceablepeeling paint
Deck, porch and/or balcony material: Wood
Condition of exterior stairs: Required repairs, replacement and/or evaluation (see comments below)front porch stairs show signs of rot at bottom
Condition of handrails: Appeared serviceable
Exterior stair material: Wood
1) One or more deck ledger boards were nailed to the building rather than being attached by adequate fasteners. This poses a significant safety hazard since the ledger board(s) may separate from the building, causing the deck(s) to collapse. A qualified contractor should install lag screws or bolts as per standard building practices to securely attach the ledger board(s) to the building. For more information on installing deck ledger boards visit:
http://www.google.com/search?q=installing+a+ledger+board

And for more information on building safe decks in general, visit: http://www.google.com/search?q=building+a+safe+deck

Photo 13  
no apparent mechanical attachment from deck to support post, deck itself is not directly in contact with post while the railing post is

Photo 14  
improper mechanical fastener, needs immediate attention

Photo 17  
improper fasteners, recommend lag bolts or through bolts installed according to local building code

Photo 18  
grading over window sill

Photo 19  
deck floor joist compromised, also decking fastners not fastened into actual joist

Photo 20  
deck floor joist compromised, also decking fastners not fastened into actual joist

Photo 11  
deck ledger pulling away from house

Photo 12  
improper grading underneath deck, soil touching bottom of basement window

Photo 15  
improper grading

Photo 22  
non GFI protected outlet on deck

Photo 10  
grading up to bottom of basement window, lower if possible or have window well installed by appropriate professional
 

2) Front Porch - Vegetation such as trees, shrubs and/or vines was in contact with or less than one foot from the building exterior. Vegetation can serve as a conduit for wood destroying insects and may retain moisture against the exterior after it rains. Vegetation should be pruned and/or removed as necessary to maintain a one foot clearance between it and the building exterior.

Photo 6  
over grown shrubbery planted to close to stone foundation

Photo 25  
front porch stair system rotting at base

3) Trees were in contact with or were close to the building in one or more areas. Damage may result, especially during high winds. Vegetation can also act as a conduit for wood destroying insects. Vegetation should be pruned back and/or removed as necessary to prevent damage and infestation by wood destroying insects.

Photo 24  
tree planted too close to foundation, 1 foot away, recommend removal
 

4) Recommend resealing asphalt driveway.
 
Exterior / Foundation Return to table of contents
Limitations: The following items are not included in this inspection: below-grade foundation walls and footings, or those obscured by vegetation or building components; exterior building surfaces or components obscured by vegetation, stored items or debris. Any comments made regarding these items are as a courtesy only. Some amount of cracking is normal in concrete slabs and foundation walls due to shrinkage and drying. Note that the inspector does not determination the adequacy of sump pumps, seismic reinforcement, nor determine if support posts, columns, beams, joists, studs, trusses, etc. are of adequate size, spanning or spacing.
Condition of wall covering: Appeared serviceable
Apparent wall structure: Wood frame
Wall covering: Wood, Vinyl
Condition of foundation and footings: Required repairs, replacement and/or evaluation (see comments below)
Foundation type: Unfinished basement
Foundation material: Poured in place concrete, Stone
Condition of floor substructure: Appeared serviceable
Pier or support post material: Steel
Beam material: Built up wood
Floor structure: Solid wood joists
Condition of crawl space: Appeared serviceablecrawl space between 2 full basements, pored concrete floor in crawlspace
Crawl space inspection method: Partially traversed
Insulation material underneath floor above: None visible
Condition of the basement: Appeared serviceable
5) Evidence of prior water intrusion was found in one or more sections of the basement. For example, water stains at support post bases, efflorescence on the foundation etc. Accumulated water is a conducive condition for wood destroying insects and organisms and should not be present in the basement. The client should review any disclosure statements available and ask the property owner about past accumulation of water in the basement. The basement should be monitored in the future for accumulated water, especially after heavy and/or prolonged periods of rain. If water is found to accumulate, a qualified contractor who specializes in drainage issues should evaluate and repair as necessary. Typical repairs for preventing water from accumulating in basements include:

  • Repairing, installing or improving rain run-off systems (gutters, downspouts and extensions or drain lines)
  • Improving perimeter grading
  • Repairing, installing or improving underground footing and/or curtain drains

    Ideally, water should not enter basements, but if water must be controlled after it enters the basement, then typical repairs include installing a sump pump.

    Photo 46  
    foundation wet in basement

    Photo 47  
    water intrusion in basement wall

    Photo 48  
    water intrusion in basement wall

    Photo 42  
    minor cracking in basement floor

    Photo 43  
    minor cracking in basement floor

    Photo 44  
    minor cracking in basement wall

    Photo 8  
    more open cracks in foundation

    Photo 23  
    door jamb showing signs of rot

    6) Small hole in vinyl siding . A qualified person should evaluate and repair, replace or install siding or trim as necessary.

    Photo 16  
    crack in vinyl siding
     

    7) Soil was in contact with or less than six inches from siding and/or trim. This is a conducive condition for wood destroying insects and organisms. Soil should be graded and/or removed as necessary so there are at least six inches of space between the siding and trim and the soil below.

    Photo 6  
    over grown shrubbery planted to close to stone foundation
     

    8) One or more minor cracks (1/8 inch or less) were found in the foundation. These don't appear to be a structural concern, but recommend sealing them to prevent water infiltration and monitoring them in the future. Numerous products exist to seal such cracks including hydraulic cement, resilient caulks and epoxy sealants.

    Photo 7  
    open cracks in foundation

    Photo 8  
    more open cracks in foundation

    Photo 44  
    minor cracking in basement wall
     
     
    Roof / Attic Return to table of contents
    Limitations: The following items or areas are not included in this inspection: areas that could not be traversed or viewed clearly due to lack of access; areas and components obscured by insulation; solar roofing components; any comments made regarding these items are as a courtesy only. Note that the inspector does not determination if rafters, trusses, joists, beams, etc. are of adequate size, spanning or spacing. The inspector does not provide an estimate of remaining roof surface life, does not determine that the roof has absolutely no leaks at the time of the inspection, and does not determine that the roof won't leak in the future. Only active leaks and evidence of past leaks observed during the inspection are reported on as part of this inspection. To absolutely determine than no leaks exist, complete access to all roof structure areas must be available during a wide variety of weather conditions, including prolonged heavy rain, high wind from varying directions, heavy accumulations of snow and/or ice, and melting snow and ice.
    Condition of roof structure: Appeared serviceable
    Roof inspection method: Traversed
    Condition of exposed flashings: not visible - vinyl j channel along roof , recommend chimney flashing be closely examined
    Condition of gutters, downspouts and extensions: Required repair, replacement and/or evaluation (see comments below)
    Gutter and downspout material: Metal
    Gutter and downspout installation: Partial
    Attic inspection method: Not inspected, no access
    Roof ventilation: Appears serviceablesoffit vents and ridge vent
    9) sections of the roof surface appeared to be near the end of their service life and will likely need replacing in the near future, even with repairs. The client should budget for a replacement roof surface, and may want to have a qualified roofing contractor evaluate and attempt to issue a "5 year roof certificate".

    Photo 5  
    roof shingles worn

    Photo 36  
    pieces of roof shingle missing

    Photo 38  
    ridge cap torn

    Photo 39  
    roofing shingle on front of house at or near life expectancy, recommend replacement

    Photo 40  
    ridge caps torn
     

    10) Extensions such as splash blocks or drain pipes for downspouts were damaged. Water may accumulate around the building foundation as a result. A qualified person should evaluate and repair, replace or install as necessary

    Photo 9  
    gutter extension needs repair
     

    11) The siding on one or more exterior walls above lower roof sections was in contact with or had less than a one inch gap between it and the roof surface below. A gap of at least one inch is recommended so water isn't wicked up into the siding from the shingles below, and also to provide room for additional layers of roofing materials when the current roof surface fails. Recommend having a qualified contractor make repairs as necessary, such as trimming siding, so at least a one inch gap exists between the siding and the roofing below where necessary.

    Photo 37  
    roof valley terminates against back wall of house
     

    12) Debris had accumulated in one or more gutters. This is a conducive condition for wood destroying insects since gutters may overflow and cause water to come in contact with the building exterior or make water accumulate around the foundation. Gutters should be cleaned now and as necessary in the future.
    13) No accessible attic spaces were found or inspected at this property.
     
    Garage / Carport Return to table of contents
    Limitations: The inspector does not determine the adequacy of firewall ratings. Requirements for ventilation in garages varies between municipalities.
    Type: Detached
    Condition of detached garage or carport structure: Appeared serviceable
    Condition of garage:
    Type of garage: Solid core, Metal
    Condition of garage vehicle door(s): Required repair, replacement and/or evaluation (see comments below)
    Condition of garage floor: Appeared serviceable
    Condition of garage interior: Appeared serviceable
    Garage ventilation: None visible
    14) One or more vehicle doors were difficult or unable to open or close. Vehicle doors should open and close smoothly and easily. A qualified person should evaluate and make repairs as necessary.
    15) The lock mechanism one or more garage vehicle doors was inoperable or difficult to operate. A qualified person should evaluate and repair as necessary so vehicle doors can be easily secured.

    Photo 30  
    garage door latch not aligned properly, won't lock
     

    16) Weatherstrip at the bottom of vehicle doors was insufficient. It should be replaced where necessary to prevent water and vermin intrusion.

    Photo 29  
    garage door seal non functional
     
     
    Electric Return to table of contents
    Limitations: The following items are not included in this inspection: generator systems, surge suppressors, inaccessible or concealed wiring; underground utilities and systems; low voltage lighting or lighting on timers or sensors. Any comments made regarding these items are as a courtesy only. Note that the inspector does not determine the adequacy of grounding or bonding, does not determine if this system has an adequate capacity for the client's specific needs, nor determine if this system has any reserve capacity for additions or expansion. The inspector does not operate circuit breakers as part of the inspection, install or change light bulbs, nor determine the operability of every wall switch.
    Electric service condition: Appeared serviceable
    Primary service type: Overhead
    Service amperage (amps): 100
    Primary service overload protection type: Circuit breakers
    Service entrance conductor material: Aluminum
    Main disconnect rating (amps): 100
    System ground: Ground rod(s) in soil, Cold water supply pipes
    Condition of main service panel: Required repair, replacement and/or evaluation (see comments below)there is rust on top of the main disconnect
    Condition of sub: Appeared serviceable
    Location of main service panel #A: Basementold basement
    Location of sub-panel #B: 2nd basement
    Location of main disconnect: Breaker at top of main service panel
    Branch circuit wiring type: Non-metallic sheathed
    Condition of branch circuit wiring: Serviceable
    Condition of smoke detectors: Appeared serviceable
    Smoke detectors present: Yes2 upstairs bedrooms, next to kitchen, master bedroom hard wired together
    Carbon monoxide detectors present: Yesmaster bedroom, upstairs stairwell, new basement, all battery operated only
    Smoke detector power source: Battery, Hard wired
    17) A qualified electrician should evaluate and install a service mast or make repairs as necessary.

    Photo 3  
    missing aluminum trim, recommend further inspection of weatherhead by liscenced electrician

    Photo 4  
    no service mast , service wires resting over edge of roof in direct contact

    Photo 28  

    Photo 41  
    masking tape over smoke detector

    Photo 45  
    non GFI outlet over sump pump in basement
     

    18) The electric service to this property appeared to be rated at substantially less than 200 amps, and may be inadequate for the client's needs. Recommend consulting with a qualified electrician about upgrading to a 200 amp service.
     
    Plumbing / Fuel Systems Return to table of contents
    Limitations: The following items are not included in this inspection: private wells and sewage disposal systems; main, side and lateral sewer lines; gray water systems; pressure boosting systems; incinerating or composting toilets; fire suppression sprinkler systems; water softeners, conditioners or filtering systems; plumbing components concealed within the foundation or building structure, or in inaccessible areas such as below tubs; underground utilities and systems; overflow drains for tubs and sinks; backflow prevention devices. Any comments made regarding these items are as a courtesy only. Note that the inspector does not operate water supply or shut-off valves due to the possibility of valves leaking or breaking when operated. The inspector does not test for lead in the water supply, the water pipes or solder, does not determine if plumbing and fuel lines are adequately sized, and does not determining the existence or condition of underground or above-ground fuel tanks.
    Condition of service and main line: Appeared serviceable
    Location of main water meter: old basement left of bottom of stairs
    Location of main water shut: above meter
    Water service: Public
    Service pipe material: Plastic
    Condition of supply lines: Appeared serviceable
    Supply pipe material: Copper
    Condition of drain pipes: Appeared serviceable
    Drain pipe material: Plastic
    Condition of waste lines: Appeared serviceable
    Waste pipe material: Plastic
    Condition of fuel system: Appeared serviceable
    Location of main fuel shut: shutoffs on top of propane tanks
    Visible fuel storage systems: 2 propane tanks outside, 1 oil tank in new basement
    19) The propane tank was leaning against the garage.

    Photo 21  
    propane tank in direct contact with garage
     

    20) The main water shut-off valve was corroded. A qualified plumber should evaluate and repair as necessary.
     
    Water Heater Return to table of contents
    Limitations: The following items are not included in this inspection: solar water heating systems; circulation systems. Any comments made regarding these items are as a courtesy only. Note that the inspector does not provide an estimate of remaining life on water heaters, does not determine if water heaters are appropriately sized, or perform any evaluations that require a pilot light to be lit.
    Condition of water heater: Appeared serviceable
    Type: hydronic from boiler
    Energy source: Oil
    Capacity (in gallons): 40
    Manufacturer: Boilermate / Amtrol Classic Series
    Model: WH7L
    Location of water heater: next to furnace
    Water temperature (degrees Fahrenheit): 120
     
    Heating Return to table of contents
    Limitations: The following items are not included in this inspection: humidifiers, dehumidifiers, electronic air filters; solar, coal or wood fired heat systems; thermostat or temperature control accuracy and timed functions; heating components concealed within the building structure or in inaccessible areas; underground utilities and systems; safety devices and controls (due to automatic operation). Any comments made regarding these items are as a courtesy only. Note that the inspector does not provide an estimate of remaining life on heating system components, does not determine if heating systems are appropriately sized, or perform any evaluations that require a pilot light to be lit. It is beyond the scope of this inspection to determine if furnace heat exchangers are intact and free of leaks.
    Condition of heating system: Appeared serviceable
    Location of heating system: Basement
    Heating type: Hot water
    Fuel type: Oil
    Manufacturer: NTI
    Last service date: April 10, 2009
    Model: 02CT5-1489
    Source for last service date: Label on heater
    Condition of burners: Not determined
    Condition of venting system: Appeared serviceable
    Condition of combustion air supply: Not determined
    Condition of distribution system: Appeared serviceable
    Condition of controls: Appeared serviceable
    21) This heating system is a specialty system, and only a limited evaluation was performed during the inspection. Recommend a full evaluation by a qualified specialist.
     
    Fireplaces / Stoves / Chimneys Return to table of contents
    Limitations: The following items are not included in this inspection: coal stoves, gas logs, chimney flues (except where visible). Any comments made regarding these items are as a courtesy only. Note that the inspector does not determine the adequacy of drafting or sizing in fireplace and stove flues, nor determine if prefabricated or zero clearance fireplaces are installed in accordance with the manufacturer's specifications. The inspector does not perform any evaluations that require a pilot light to be lit.
    Condition of fireplaces, stoves: Appeared serviceable
    Location #A: main living room
    Fireplace type: Masonry
    Stove type: Insert
    Fuel type: Wood
    Condition of chimneys: Appeared serviceable
    Chimney type: Masonry
    22) The fireplace hearth only extends 6 " in front of woodstove .
    23) The rain cap for the chimney flue at location was missing.
     
    Kitchen Return to table of contents
    Limitations: The following items are not included in this inspection: free-standing or portable appliances such as dishwashers, trash compactors, refrigerators, freezers, ice makers; specialty appliances such as hot water dispensers, water filters and trash compactors; appliance timers, clocks, cook functions, self and/or continuous cleaning operations, thermostat or temperature control accuracy, and lights. Any comments made regarding these items are as a courtesy only. Note that the inspector does not provide an estimate of the remaining life of appliances, and does not determine the adequacy of operation of appliances such as dishwashers, garbage disposals, trash compactors, ovens, broilers, etc.
    Condition of counters: Appeared serviceable
    Condition of cabinets: Appeared serviceable
    Condition of sinks and related plumbing: Appeared serviceable
    Condition of dishwasher: Appeared serviceable
    Condition of range, cooktop: Appeared serviceable
    Range, cooktop type: Natural gas
    Condition of refrigerator: Appeared serviceable
    Condition of built: Appeared serviceable
     
    Bathrooms / Laundry / Sinks Return to table of contents
    Limitations: The following items are not included in this inspection: overflow drains for tubs and sinks; bidets, heated towel racks, saunas, steam generators, clothes washers, clothes dryers. Any comments made regarding these items are as a courtesy only. Note that the inspector does not determine the adequacy of washing machine drain lines, washing machine catch pan drain lines, or clothes dryer exhaust ducts. The inspector does not operate water supply or shut-off valves for sinks, toilets, bidets, clothes washers, etc. due to the possibility of valves leaking or breaking when operated. The inspector does not determine if shower pans or tub and shower enclosures are water tight, or determine the completeness or operability of any gas piping to laundry appliances.
    Location #A: off kitchen
    Location #B: master bedroom
    Condition of counters: Appeared serviceable
    Condition of cabinets: Appeared serviceable
    Condition of sinks and related plumbing: Required repair, replacement and/or evaluation (see comments below)A
    Condition of toilets: Appeared serviceable
    Condition of bathtubs and related plumbing: Appeared serviceable
    Condition of shower(s) and related plumbing: Appeared serviceable
    Condition of ventilation systems: Appeared serviceable
    240 volt receptacle for laundry equipment present: Yes
    Condition of laundry facilities: Required repair, replacement and/or evaluation (see comments below)non GFI outlet behind washing machine
    24) The clothes dryer exhaust hose is too long and has kinks in it, possibly restricting exhaust flow.

    Photo 32  
    dryer vent hose too long , kinked, ventilation compromised

    Photo 33  
    non GFI outlet behind washing machine

    25) The sink at location A drained slowly. A qualified person should evaluate and repair as necessary.
     
    Interior Rooms / Areas Return to table of contents
    Limitations: The following items are not included in this inspection: security, intercom and sound systems; communications wiring; central vacuum systems; elevators and stair lifts; sources of obnoxious odors; cosmetic deficiencies due to normal wear and tear in wall, floor and ceiling surfaces and coverings, or in equipment; deficiencies relating to interior decorating; low voltage and gas lighting systems. Any comments made regarding these items are as a courtesy only. Note that the inspector does not evaluate any areas or items which require moving stored items, furnishings, debris, equipment, floor coverings, insulation or similar materials. The inspector does not test for asbestos, lead, radon, mold, hazardous waste, urea formaldehyde urethane, or any other toxic substance. Some items such as window operability are tested on a sampled basis. The client should be aware that paint may obscure wall and ceiling defects, floor coverings may obscure floor defects, and furnishings may obscure wall, floor and floor covering defects. If furnishings were present during the inspection, recommend a full evaluation of walls, floors and ceilings that were previously obscured when possible. Determining the cause of odors is not within the scope of this inspection.
    Exterior door material: Fiberglass or vinyl
    Condition of exterior entry doors: Appeared serviceable
    Condition of interior doors: Appeared serviceable
    Type of windows: Double hung
    Condition of windows: Required repair, replacement and/or evaluation (see comments below)4 windows are fogged between double insulated glass
    Wall type or covering: Drywall
    Condition of walls: Appeared serviceable
    Ceiling type or covering: Drywall
    Condition of ceilings: Required repairs, replacement and/or evaluation (see comments below)
    Flooring type or covering: Wood, Tile
    26) Multiple windows have defects, fog between the insulated glass . A qualified person should evaluate and repair or replace as necessary.

    Photo 26  
    window seal compromised, fooged

    Photo 27  
    upper window sash bowed, window seal compromised

    Photo 31  
    master bedroom window seal compromised, fogged

    Photo 34  
    front living room window seal compromised, fogged

    Photo 35  
    front living room screen torn
     

    27) Some tile flooring in the kitchen have cracks.

    Photo 49  
    cracked floor tiles in kitchen

    Photo 50  
    cracked floor tiles in kitchen floor

    28) Minor cracks and/or holes were found in ceilings in one or more areas. They do not appear to be a structural concern, but the client may wish to repair these for aesthetic reasons.

    Photo 1  
    apparent water damage, recommend inspection of chimney flashing

    Photo 2  
    cracks along tape in ceiling drywall

    29) Recommend cleaning and sealing grout in tile or stone flooring now and in the future as necessary to prevent staining and to improve waterproofing.
     
    Your default report footer here...