Property Inspection Report
Client(s): Mr. John Foster
Property address: 521 McKeller Drive
Inspection date: 3/23/2010
This report published on Sunday, March 28, 2010 10:36:06 PM CDT

View summary page

This report is the exclusive property of this inspection company and the client(s) listed in the report title. Use of this report by any unauthorized persons is prohibited.

 
How to Read this Report
This report is organized by the property's functional areas.  Within each functional area, descriptive information is listed first and is shown in bold type.  Items of concern follow descriptive information.
Concerns are shown and sorted according to these types:
SafetyPoses a risk of injury or death 
Repair/ReplaceRecommend repairing or replacing 
Minor DefectCorrection likely involves only a minor expense 
MaintainRecommend ongoing maintenance 
EvaluateRecommend evaluation by a specialist 
CommentFor your information 

Click here for a glossary of building construction terms.  Contact your inspector if there are terms that you do not understand, or visit the glossary of construction terms at http://www.reporthost.com/glossary.asp

Table of Contents
General information
Exterior
Roof
Attic
Electric service
Water heater
Heating and cooling
Plumbing and laundry
Kitchen
Bathrooms
Interior rooms
 
General information Return to table of contents
Report number: 1
Inspector's name: John Cubit
Structures inspected: 1
Type of building: Single family
Age of building: 60 yr.
Property owner's name: Mr.John Foster
Time started: 9 am
Time finished: 1 pm
Payment method: Cash
Present during inspection: Client(s), Realtor(s)
Occupied: No
Weather conditions: Partly cloudy
Temperature: Cool
Ground condition: Damp
Front of structure faces: North
Main entrance faces: North
Foundation type: Crawlspace
The following items are excluded from this inspection: Shed, Outbuildings
1) Structures built prior to 1979 may contain lead-based paint and/or asbestos in various building materials such as insulation, siding, and/or floor and ceiling tiles. Both lead and asbestos are known health hazards. Evaluating for the presence of lead and/or asbestos is not included in this inspection. The client(s) should consult with specialists as necessary, such as industrial hygienists, professional labs and/or abatement contractors for this type of evaluation. For information on lead, asbestos and other hazardous materials in homes, visit these websites:
  • The Environmental Protection Association (http://www.epa.gov)
  • The Consumer Products Safety Commission (http://www.cpsc.gov)
  • The Center for Disease Control (http://www.cdc.gov)
    2) Many wall, floor and/or ceiling surfaces were obscured by large amounts of furniture and/or stored items. Many areas couldn't be evaluated.
     
    Exterior Return to table of contents
    Footing material: Poured in place concrete
    Foundation material: Post and pier
    Apparent wall structure: Wood frame brick veneer.
    Wall covering: Brick veneer, Vinyl
    Driveway material: Asphalt
    Exterior door material: Solid core steel
    Sidewalk material: Poured in place concrete
     
    Roof Return to table of contents
    Roof inspection method: Viewed from eaves on ladder, Viewed from ground with binoculars
    Roof type: GableNew roof
    Roof covering: Asphalt or fiberglass composition shinglesNew roof.
    Estimated age of roof: 1 year old
    Gutter & downspout material: AluminumNew gutters.
    Roof ventilation: Adequate
    3) One or more "rubber boot" flashings are lifting at the base or are improperly installed so that water or vermin intrusion may occur. A qualified contractor should make repairs as necessary, such as permanently fastening down the lifted edge(s), or reinstalling flashings.

    Photo 14  
    recommend extending pipe.
     

    4) New gutters
    5) Trees are overhanging roof and are within 10 feet of roof vertically. This is a conducive condition for wood destroying insects and organisms since organic debris such as leaves or needles are more likely to accumulate on the roof surface. Accumulated debris may cause water to enter gaps in the roof surface and leak into attic and/or interior spaces. Trees should be pruned so they are at least 10 feet above roof, or don't overhang the roof.
    6) Because of the roof covering type and/or the configuration of the roof, the inspector was unable to traverse the roof and wasn't able to fully evaluate the entire roof.

    Photo 9  
    new roof

    Photo 11  
    New roof.

    Photo 14  
    recommend extending pipe.
     
     
    Attic Return to table of contents
    Inspection method: Partially traversed
    Roof structure type: Rafters
    Ceiling structure: Ceiling beams
    Insulation material: Fiberglass roll or batt, Cellulose loose fillRecommend removing bat insulation from roof sheating to prevent shingle overheating.
    Insulation depth: 13 in
    Insulation estimated R value: 30
    7) Cover plate(s) are broken at one or more electric boxes, such as for receptacles, switches and/or junction boxes. They are intended to contain fire and prevent electric shock from exposed wires. This is a safety hazard due to the risk of fire and shock. Cover plates should be replaced where necessary.

    Photo 19  
    open receiptical in attic.hot.

    Photo 23  
    open recepitical in attic.hot.

    8) Some attic areas were inaccessible due to lack of permanently installed walkways, the possibility of damage to insulation, low height and/or stored items. These areas are excluded from this inspection.

    Photo 18  
    recommend removing insulation from roof structure to eliminate shingle overheating.

    Photo 21  
    loose insulation in attic.recommend removing to prevent shingle overheating.
     
    Electric service Return to table of contents
    Primary service type: OverheadService to house is to low to metal carport roof.
    Primary service overload protection type: Circuit breakers
    Service amperage (amps): 200
    Service voltage (volts): 120/240
    Location of main service switch: Top of panal
    Location of sub panels: above breaker panal
    Location of main disconnect: Breaker at top of main service panel
    Service entrance conductor material: Aluminum
    System ground: Ground rod(s) in soil
    Main disconnect rating (amps): 200
    Branch circuit wiring type: Non-metallic sheathed
    Solid strand aluminum branch circuit wiring present: Yes
    Smoke detectors present: No
    9) The service drop wires are less than 3 feet from one or more doors, balconies, decks and/or windows that open. This is a safety hazard due to the risk of shock. A qualified electrician and/or the utility company should evaluate and repair as necessary.

    Photo 17  
    service line to close to metal roof.
     

    10) The service drop wires are less than three feet above one or more sections of roof with a slope of 3/12 (three inches vertical for every 12 inches horizontal) or more. This is a safety hazard for shock since people on the roof may come into contact with the service drop wires. The utility company and/or a qualified electrician should evaluate and repair as necessary.

    Photo 17  
    service line to close to metal roof.
     

    11) The service drop wires are less than eight feet above one or more sections of flat roof that can be walked on. This is a safety hazard for shock since people on the roof may come into contact with the service drop wires. The utility company and/or a qualified electrician should evaluate and repair as necessary.

    Photo 17  
    service line to close to metal roof.
     

    12) One or more knockouts have been removed inside the main service panel where no wires and bushings are installed, and no cover(s) have been installed to seal the hole(s). This is a safety hazard due to the risk of fire. A qualified electrician should install knockout covers where missing.

    Photo 24  
    missing breaker cover.safety hazard.
     

    13) The main service panel cover couldn't be removed due to lack of access from stored items and/or debris. This panel wasn't fully evaluated.

    Photo 27  
    Dirty panal box.
     
     
    Water heater Return to table of contents
    Estimated age: 5 year old
    Type: Tank
    Energy source: Electricity
    Capacity (in gallons): 50
    Manufacturer: American
    Water temperature (degrees Fahrenheit): 119
     
    Heating and cooling Return to table of contents
    Estimated age: 4 year old heat pump
    Primary heating system energy source: Electric
    Primary heat system type: Forced air, Heat pump, Standard efficiency
    Primary A/C energy source: ElectricWould not operate on ac
    Primary Air conditioning type: Heat pump
    Distribution system: Sheet metal ducts, Flexible ducts
    Manufacturer: American Standard
    Last service date: 2/10
    14) The air conditioning system did not respond when its controls were operated. This system was not fully evaluated. The client(s) should consult with the property owner(s) as to how it operates and have a qualified heating and cooling contractor evaluate and make repairs if necessary.

    Photo 10  
    4 year old heat pump.AC would not work.
     

    15) The outdoor air temperature was below 60 degrees Fahrenheit during the inspection. Because of this, the inspector was unable to operate and fully evaluate the cooling system.

    Photo 10  
    4 year old heat pump.AC would not work.
     
     
    Plumbing and laundry Return to table of contents
    Water pressure (psi): 62
    Location of main water shut-off valve: At meter front yard and in crawlspace in coming line front of house.
    Location of main water meter: same as above
    Water service: Public
    Service pipe material: Polyethelene
    Supply pipe material: CPVC
    Vent pipe material: Plastic, Cast iron
    Waste pipe material: Plastic, Cast iron
    16) Water pressure is below 40 psi, but the flow appeared to be adequate. 40-80 psi is considered to be the normal range for water pressure in a home. The inspector performed a "functional flow test" during the inspection, where multiple fixtures are run simultaneously, and found there to be adequate flow. For example, the shower flow did not decrease significantly when the toilet was flushed.

    If the client finds the flow to be inadequate, recommend having a qualified plumber evaluate and repair as necessary. Installing a pressure boosting system is one possible solution. For information, visit:
    http://www.google.com/search?q=low+water+pressure

    17) No clothes dryer exhaust duct is installed. Clothes dryers produce large amounts of moisture which should not enter structure interiors. Damage to building components may result. A rigid or semi-rigid metal exhaust duct should be installed as per standard building practices, and by a qualified contractor if necessary. For information, visit:
    http://www.cpsc.gov/CPSCPUB/PUBS/5022.html

    Photo 28  
    Mix of pvc and cast iron drain pipe.

    Photo 30  
    220 receptical loose for dryer
     
    Kitchen Return to table of contents

    18)   All new
     
    Bathrooms Return to table of contents

    19) One or more open ground, three-pronged electric receptacles were found. This is a safety hazard due to the risk of shock. A qualified electrician should evaluate and make repairs as necessary. For example, replacing receptacles or correcting wiring circuits.

    Grounding type receptacles began being required in residential structures during the 1960s. Based on the age of this structure and the presence of 2-pronged receptacles in some areas of this structure, an acceptable repair may be to simply replace the ungrounded 3-pronged receptacles with 2-pronged receptacles. However the following appliances require grounding type receptacles:

  • Computer hardware
  • Refrigerators
  • Freezers
  • Air conditioners
  • Clothes washers
  • Clothes dryers
  • Dishwashers
  • Kitchen food waste disposers
  • Information technology equipment
  • Sump pumps
  • Electrical aquarium equipment
  • Hand-held motor-operated tools
  • Stationary and fixed motor-operated tools
  • Light industrial motor-operated tools
  • Hedge clippers
  • Lawn mowers

    This list is not exhaustive. Grounded circuits and receptacles should be installed in locations where such appliances will be used.
    20) One or more open ground, three-pronged grounding type receptacles were found. This is a safety hazard due to the risk of shock. A qualified electrician should evaluate and make repairs as necessary.

    Grounding type receptacles were first required in residential structures during the 1960s. Based on the age of this structure and/or the absence of 2-pronged receptacles, repairs should be made by correcting wiring circuits as necessary so all receptacles are grounded as per standard building practices. Replacement of three-pronged receptacles with 2-pronged receptacles is not an acceptable solution.

    Photo 16  
    no ground.

    Photo 22  
    nuetral reversed bedroom.

    21) One or more electric receptacles have reverse-polarity wiring, where the hot and neutral wires are reversed. This is a safety hazard due to the risk of shock. A qualified electrician should evaluate and make repairs as necessary.

    Photo 22  
    nuetral reversed bedroom.
     

    22) One or more electric receptacles that serve countertop surfaces within six feet of a sink appear to have no ground fault circuit interrupter (GFCI) protection. This is a safety hazard due to the risk of shock. A qualified electrician should evaluate to determine if GFCI protection exists, and if not, repairs should be made so that all receptacles that serve countertop surfaces within six feet of sinks have GFCI protection. For example, install GFCI receptacles or circuit breaker(s) as needed.
    23)   All new fixtures.No ground on electric
     
    Interior rooms Return to table of contents

    24) One or more open ground, three-pronged electric receptacles were found. This is a safety hazard due to the risk of shock. A qualified electrician should evaluate and make repairs as necessary. For example, replacing receptacles or correcting wiring circuits.

    Grounding type receptacles began being required in residential structures during the 1960s. Based on the age of this structure and the presence of 2-pronged receptacles in some areas of this structure, an acceptable repair may be to simply replace the ungrounded 3-pronged receptacles with 2-pronged receptacles. However the following appliances require grounding type receptacles:

  • Computer hardware
  • Refrigerators
  • Freezers
  • Air conditioners
  • Clothes washers
  • Clothes dryers
  • Dishwashers
  • Kitchen food waste disposers
  • Information technology equipment
  • Sump pumps
  • Electrical aquarium equipment
  • Hand-held motor-operated tools
  • Stationary and fixed motor-operated tools
  • Light industrial motor-operated tools
  • Hedge clippers
  • Lawn mowers

    This list is not exhaustive. Grounded circuits and receptacles should be installed in locations where such appliances will be used.

    Photo 16  
    no ground.

    Photo 22  
    nuetral reversed bedroom.

    Photo 29  
    Panal box wiring.
     

    25) One or more open ground, three-pronged grounding type receptacles were found. This is a safety hazard due to the risk of shock. A qualified electrician should evaluate and make repairs as necessary.

    Grounding type receptacles were first required in residential structures during the 1960s. Based on the age of this structure and/or the absence of 2-pronged receptacles, repairs should be made by correcting wiring circuits as necessary so all receptacles are grounded as per standard building practices. Replacement of three-pronged receptacles with 2-pronged receptacles is not an acceptable solution.

    Photo 16  
    no ground.

    Photo 22  
    nuetral reversed bedroom.

    26) One or more electric receptacles have reverse-polarity wiring, where the hot and neutral wires are reversed. This is a safety hazard due to the risk of shock. A qualified electrician should evaluate and make repairs as necessary.

    Photo 22  
    nuetral reversed bedroom.
     

    27) One or more electric receptacles that serve countertop surfaces within six feet of a sink appear to have no ground fault circuit interrupter (GFCI) protection. This is a safety hazard due to the risk of shock. A qualified electrician should evaluate to determine if GFCI protection exists, and if not, repairs should be made so that all receptacles that serve countertop surfaces within six feet of sinks have GFCI protection. For example, install GFCI receptacles or circuit breaker(s) as needed.
    28) No smoke alarms are visible. This is a safety hazard. A qualified electrician should install smoke alarms as per standard building practices (functioning one exists in hallways leading to bedrooms, and in each bedroom, etc.). For more information, visit:
    http://www.cpsc.gov/cpscpub/pubs/5077.html

    29) This structure was built prior to 1979 and may contain lead paint. Laws were enacted in 1978 in the US preventing the use of lead paint in residential structures. Lead is a known safety hazard, especially to children but also to adults. The paint found in and around this structure appeared to be intact and may be encapsulated by more recent layers of paint that are not lead-based. Regardless, recommend following precautions as described in the following links to Consumer Products Safety Commission website articles regarding possible lead paint.

    What You Should Know About Lead Based Paint in Your Home: Safety Alert - CPSC Document #5054

    CPSC Warns About Hazards of "Do lt Yourself" Removal of Lead Based Paint: Safety Alert - CPSC Document #5055

    30) Squeaking or creaking noises occur when walking on one or more sections of flooring. This is usually caused by substandard construction practices where the subfloor decking is not adequately fastened to the framing below. For example, not enough glue was used and/or nails were used rather than screws. In most cases, this is only an annoyance rather than a structural problem. Various solutions such as Squeeeeek No More and Counter Snap fasteners exist to correct this. Repairs to eliminate the squeaks or creaks may be more or less difficult depending on the floor covering, and the access to the underside of the subfloor. Recommend having a qualified contractor evaluate and repair as necessary. For more information, visit:
    http://www.google.com/search?hl=en&q=squeaky+floors
     

    Photo 1  
    Minor settlement over the years

    Photo 2  
    Cracks.recommend resurfacing.

    Photo 3  
    Recommend downspout extentions

    Photo 4  
    Recommend regrading yard.

    Photo 5  
    water shut off at meter and also in crawlspace.

    Photo 6  
    Front view of home.

    Photo 7  
    Minor cracks in carport slab.

    Photo 8  
    loose crawlspace vent right side of house

    Photo 12  
    Electrical service line to close to metal carport roof.

    Photo 13  
    Recommend regrading back away from foundation.

    Photo 15  
    loose at wall leaking.

    Photo 20  
    loose hand railing front porch.

    Photo 25  
    pipe tpr and pn to ouside.

    Photo 26  
    Trim bushes from house.

    Photo 31  
    There has been some resupporting of floor structure over the years.

    Photo 32  
    Cast iron drain pipe through cut out floor joist.

    Photo 33  

    Photo 34  

    Photo 35  

    Photo 36  

    Photo 37  

    Photo 38  

    Photo 39  

    Photo 40  

    Photo 41  
     

     